首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 861 毫秒
1.
目的血管搭桥术后的内膜增生往往导致手术失败,而内膜增生与搭桥血管内的流场密切相关,为改善搭桥血管中的流场结构,作者设计了偏心搭桥手术方法,利用计算机数值模拟技术,探索偏心搭桥和传统搭桥血管中流场的变化,为血管搭桥方法提供优化设计方案。方法16只犬随机分为偏心搭桥组和传统搭桥组进行血管搭桥,测定搭桥前后血管几何数据,搭桥后近心端及远心端吻合口血流量和血压。按测定的血管几何数据,FLUENT 6.2模拟搭桥血管内的流场。结果偏心搭桥近心端和远心端吻合口不在同一平面。传统搭桥中,主体动脉远心端吻合口对应面处存在一个较低壁面剪切应力(WSS)区域及流体停滞点,离脚跟较近的一部分流体会形成涡漩,血流进入主体动脉后,还会表现出迪恩涡二次流;偏心搭桥中,主体动脉吻合口对应面上的低WSS区域和流体停滞点消失,血流接触到吻合口底面后,以切向旋转的方式改变其流动方向,不会形成涡漩,且当血流进入主体动脉后,立即发生螺旋流态且能持续很长一段。结论偏心搭桥能够产生血液旋动流,显著增加远心端血流量、提高WSS。  相似文献   

2.
The formation of distal anastomotic intimal hyperplasia (IH), one common mode of bypass graft failure, has been shown to occur in the areas of disturbed flow particular to this site. The nature of theflow in the segment of artery proximal to the distal anastomosis varies from case to case depending on the clinical situation presented. A partial stenosis of a bypassed arterial segment may allow residual prograde flow through the proximal artery entering the distal anastomosis of the graft. A complete stenosis may allow for zero flow in the proximal artery segment or retrograde flow due to the presence of small collateral vessels upstream. Although a number of investigations on the hemodynamics at the distal anastomosis of an end-to-side bypass graft have been conducted, there has not been a uniform treatment of the proximal artery flow condition. As a result, direct comparison of results from study to study may not be appropriate. The purpose of this work was to perform a three-dimensional computational investigation to study the effect of the proximal artery flow condition (i.e., prograde, zero, and retrograde flow) on the hemodynamics at the distal end-to-side anastomosis. We used the finite volume method to solve the full Navier-Stokes equations for steady flow through an idealized geometry of the distal anastomosis. We calculated the flow field and local wall shear stress (WSS) and WSS gradient (WSSG) everywhere in the domain. We also calculated the severity parameter (SP), a quantification of hemodynamic variation, at the anastomosis. Our model showed a marked difference in both the magnitude and spatial distribution of WSS and WSSG. For example, the maximum WSS magnitude on the floor of the artery proximal to the anastomosis for the prograde and zero flow cases is 1.8 and 3.9 dynes/cm2, respectively, while it is increased to 10.3 dynes/cm2 in the retrograde flow case. Similarly, the maximum value of WSSG magnitude on thefloor of the artery proximal to the anastomosis for the prograde flow case is 4.9 dynes/cm3, while it is increased to 13.6 and 24.2 dynes/cm3, respectively, in the zero and retrograde flow cases. The value of SP is highest for the retrograde flow case (13.7 dynes/cm3) and 8.1 and 12.1 percent lower than this for the prograde (12.6 dynes/cm3) and zero (12.0 dynes/cm3) flow cases, respectively. Our model results suggest that the flow condition in the proximal artery is an important determinant of the hemodynamics at the distal anastomosis of end-to-side vascular bypass grafts. Because hemodynamic forces affect the response of vascular endothelial cells, the flow situation in the proximal artery may affect IH formation and, therefore, long-term graft patency. Since surgeons have some control over the flow condition in the proximal artery, results from this study could help determine which flow condition is clinically optimal.  相似文献   

3.
A pulsatile flow in vitro model of the distal end-to-side anastomosis of an arterial bypass graft was used to examine the effects that different flow ratios between the proximal outlet segment (POS) and the distal outlet segment (DOS) have on the flow patterns and the distributions of hemodynamic factors in the anastomosis. Amberlite particles were tracked by flow visualization to determine overall flow patterns and velocity measurements were made with Laser Doppler anemometry (LDA) to obtain detailed hemodynamic factors along the artery floor and the graft hood regions. These factors included wall shear stress (WSS), spatial wall shear stress gradient (WSSG), and oscillatory index (OSI). Statistical analysis was used to compare these hemodynamic factors between cases having different POS:DOS flow ratios (Case 1-0:100, Case 2-25:75, Case 3-50:50). The results showed that changes in POS:DOS flow ratios had a great influence on the flow patterns in the anastomosis. With an increase in proximal outlet flow, the range of location of the stagnation point along the artery floor decreased, while the extent of flow separation along the graft hood increased. The statistical results showed that there were significant differences (p<0.05) for the mean WSS between cases along the graft hood, but no significant differences were detected along the artery floor. There were no significant differences for the spatial WSSG along both the artery floor and the graft hood. However, there were significant differences (p<0.05) in the mean OSI between Cases 1 and 2 and between Cases 1 and 3 both along the artery floor and along the graft hood. Comparing these mechanical factors with histological findings of intimal hyperplasia formation obtained by previous canine studies, the results of the statistical analysis suggest that regions exposed to a combination of low mean WSS and high OSI may be most prone to the formation of intimal hyperplasia.  相似文献   

4.
A potential interaction between the local hemodynamics and the artery wall response has been suggested for vascular graft failure by intimal hyperplasia (IH). Among the various hemodynamic factors, wall shear stress has been implicated as the primary factor responsible for the development of IH. In order to explore the role of hemodynamics in the formation of IH in end-to-side anastomosis, computational fluid dynamics is employed. To validate the numerical simulations, comparisons with existing experimental data are performed for both steady and pulsatile flows. Generally, good agreement is observed with the velocity profiles whereas some discrepancies are found in wall shear stress (WSS) distributions. Using the same end-to-side anastomosis geometry, numerical simulations are extended using a femoral artery waveform to identify the possible role of unsteady hemodynamics. In the current simulations, Carreau-Yasuda model is used to account for the non-Newtonian nature of blood. Computations indicated a disturbed flow field at the artery-graft junction leading to locally elevated shear stresses on the vascular wall. Furthermore, the shear stress distribution followed the same behavior with oscillating magnitude over the entire flow cycle. Thus, distal IH observed in end-to-side artery-graft models may be caused by the fluctuations in WSS's along the wall.  相似文献   

5.
The observation of intimal hyperplasia at bypass graft anastomoses has suggested a potential interaction between local hemodynamics and vascular wall response. Wall shear has been particularly implicated because of its known effects upon the endothelium of normal vessels and, thus, was examined as to its possible role in the development of intimal hyperplasia in arterial bypass graft distal anastomoses. Tapered (4-7 mm I.D.) e-PTFE synthetic grafts 6 cm long were placed as bilateral carotid artery bypasses in six adult, mongrel dogs weighing between 25 and 30 kg with distal anastomotic graft-to-artery diameter ratios (DR) of either 1.0 or 1.5. Immediately following implantation, simultaneous axial velocity measurements were made in the toe and artery floor regions in the plane of the anastomosis at radial increments of 0.35 mm, 0.70 mm, and 1.05 mm using a specially designed 20 MHz triple crystal ultrasonic wall shear rate transducer Mean, peak, and pulse amplitude wall shear rates (WSRs), their absolute values, the spatial and temporal wall shear stress gradients (WSSG), and the oscillatory shear index (OSI) were computed from these velocity measurements. All grafts were harvested after 12 weeks implantation and measurements of the degree of intimal hyperplasia (IH) were made along the toe region and the artery floor of the host artery in 1 mm increments. While some IH occurred along the toe region (8.35+/-23.1 microm) and was significantly different between DR groups (p<0.003), the greatest amount occurred along the artery floor (81.6+/-106.5 microm, mean +/- S.D.) (p < 0.001) although no significant differences were found between DR groups. Linear regressions were performed on the paired IH and mean, peak, and pulse amplitude WSR data as well as the absolute mean, peak, and pulse amplitude WSR data from all grafts. The mean and absolute mean WSRs showed a modest correlation with IH (r = -0.406 and -0.370, respectively) with further improvements seen (r = -0.482 and -0.445, respectively) when using an exponential relationship. The overall best correlation was seen against an exponential function of the OSI (r = 0.600). Although these correlation coefficients were not high, they were found to be statistically significant as evidenced by the large F-statistic obtained. Finally, it was observed that over 75 percent of the IH occurred at or below a mean WSR value of 100 s(-1) while approximately 92 percent of the IH occurred at or below a mean WSR equal to one-half that of the native artery. Therefore, while not being the only factor involved, wall shear (and in particular, oscillators wall shear) appears to provide a stimulus for the development of anastomotic intimal hyperplasia.  相似文献   

6.
Wall shear has been widely implicated as a contributing factor in the development of intimal hyperplasia in the anastomoses of chronic arterial bypass grafts. Earlier studies have been restricted to either: (1) in vitro or computer simulation models detailing the complex hemodynamics within an anastomosis without corresponding biological responses, or (2) in vivo models that document biological effects with only approximate wall shear information. Recently, a specially designed pulse ultrasonic Doppler wall shear rate (PUDWSR) measuring device has made it possible to obtain three near-wall velocity measurements nonintrusively within 1.05 mm of the vessel luminal surface from which wall shear rates (WSRs) were derived. It was the purpose of this study to evaluate the effect of graft caliber, a surgically controllable variable, upon local hemodynamics, which, in turn, play an important role in the eventual development of anastomotic hyperplasia. Tapered (4-7 mm I.D.) 6-cm-long grafts were implanted bilaterally in an end-to-side fashion with 30 deg proximal and distal anastomoses to bypass occluded common carotid arteries of 16 canines. The bypass grafts were randomly paired in contralateral vessels and placed such that the graft-to-artery diameter ratio, DR, at the distal anastomosis was either 1.0 or 1.5. For all grafts, the average Re was 432 +/- 112 and the average Womersley parameter, alpha, was 3.59 +/- 0.39 based on artery diameter. There was a sharp skewing of flow toward the artery floor with the development of a stagnation point whose position varied with time (up to two artery diameters) and DR (generally more downstream for DR = 1.0). Mean WSRs along the artery floor for DR = 1.0 and 1.5 were found to range sharply from moderate to high retrograde values (589 s-1 and 1558 s-1, respectively) upstream to high antegrade values (2704 s-1 and 2302 s-1, respectively) immediately downstream of the stagnation point. Although there were no overall differences in mean and peak WSRs between groups, there were significant differences (p < 0.05) in oscillatory WSRs as well as in the absolute normalized mean and peak WSRs between groups. There were also significant differences (p < 0.05) in mean and peak WSRs with respect to axial position along the artery floor for both DR cases. In conclusion, WSR varies widely (1558 s-1 retrograde to 2704 s-1 antegrade) within end-to-side distal graft anastomoses, particularly along the artery floor, and may play a role in the development of intimal hyperplasia through local alteration of mass transport and mechano-signal transduction within the endothelium.  相似文献   

7.
Chen J  Lu XY  Wang W 《Journal of biomechanics》2006,39(11):1983-1995
Non-Newtonian fluid flow in a stenosed coronary bypass is investigated numerically using the Carreau-Yasuda model for the shear thinning behavior of the blood. End-to-side coronary bypass anastomosis is considered in a simplified model geometry where the host coronary artery has a 75% severity stenosis. Different locations of the bypass graft to the stenosis and different flow rates in the graft and in the host artery are studied. Particular attention is given to the non-Newtonian effect of the blood on the primary and secondary flow patterns in the host coronary artery and the wall shear stress (WSS) distribution there. Interaction between the jet flow from the stenosed artery and the flow from the graft is simulated by solving the three-dimensional Navier-Stokes equation coupled with the non-Newtonian constitutive model. Results for the non-Newtonian flow, the Newtonian flow and the rescaled Newtonian flow are presented. Significant differences in axial velocity profiles, secondary flow streamlines and WSS between the non-Newtonian and Newtonian fluid flows are revealed. However, reasonable agreement between the non-Newtonian and the rescaled Newtonian flows is found. Results from this study support the view that the residual flow in a partially occluded coronary artery interacts with flow in the bypass graft and may have significant hemodynamic effects in the host vessel downstream of the graft. Non-Newtonian property of the blood alters the flow pattern and WSS distribution and is an important factor to be considered in simulating hemodynamic effects of blood flow in arterial bypass grafts.  相似文献   

8.
Research studies over the last three decades have established that hemodynamic interactions with the vascular surface as well as surgical injury are inciting mechanisms capable of eliciting distal anastomotic intimal hyperplasia (IH) and ultimate bypass graft failure. While abnormal wall shear stress (WSS) conditions have been widely shown to affect vascular biology and arterial wall self-regulation, the near-wall localization of critical blood particles by convection and diffusion may also play a significant role in IH development. It is hypothesized that locations of elevated platelet interactions with reactive or activated vascular surfaces, due to injury or endothelial dysfunction, are highly susceptible to IH initialization and progression. In an effort to assess the potential role of platelet-wall interactions, experimentally validated particle-hemodynamic simulations have been conducted for two commonly implemented end-to-side anastomotic configurations, with and without proximal outflow. Specifically, sites of significant particle interactions with the vascular surface have been identified by a novel near-wall residence time (NWRT) model for platelets, which includes shear stress-based factors for platelet activation as well as endothelial cell expression of thrombogenic and anti-thrombogenic compounds. Results indicate that the composite NWRT model for platelet-wall interactions effectively captures a reported shift in significant IH formation from the arterial floor of a relatively high-angle (30 deg) graft with no proximal outflow to the graft hood of a low-angle graft (10 deg) with 20% proximal outflow. In contrast, other WSS-based hemodynamic parameters did not identify the observed system-dependent shift in IH formation. However, large variations in WSS-vector magnitude and direction, as encapsulated by the WSS-gradient and WSS-angle-gradient parameters, were consistently observed along the IH-prone suture-line region. Of the multiple hemodynamic factors capable of eliciting a hyperplastic response at the cellular level, results of this study indicate the potential significance of platelet-wall interactions coinciding with regions of low WSS in the development of IH.  相似文献   

9.
Local oxygen lack in arterial walls (hypoxia) plays a very important role in the initiation, progression and development of intimal hyperplasia (IH) and thrombosis. Aiming to find out whether a helical-type artery bypass graft (ABG) is hypoxia beneficial, a numerical study was carried out to compare oxygen transport between a helical-type ABG and a conventional-type ABG. The dimensionless mass transfer coefficient (Sherwood number) was introduced to evaluate the oxygen mass transfer distribution and detailed oxygen wall flux was computed. The results show that the intrinsic geometry of a helical-type ABG resulted in improved hypoxia and the oxygen-depleted fluid located proximally to the occluded section as compared with that of a conventional-type ABG. However, benefits aside, distinct double low regions (low wall shear stress (WSS) and hypoxia) which might be most prone to IH and more localised and thicker boundary layer of oxygen-depleted fluid were observed at the helical-type ABG. This may explain why the helical flow plays a detrimental role at some locations in the human body. In addition, it was observed that although low WSS region was always accompanied with low oxygen supply, the oxygen transport rate did not adjust simultaneously with flow. The change in oxygen distribution usually lagged behind the flow change. A physiological WSS region may be associated with hypoxia condition. This study captured the qualitative trend of oxygen distribution in ABGs and the effect of helical geometry on reducing hypoxia, which is useful in the structural design of swirling flow vascular devices.  相似文献   

10.
The Coronary Artery Bypass Graft (CABG) yields excellent results and remains the modern standard of care for treatment of occlusive disease in the cardiovascular system. However, the development of anastomotic Intimal Hyperplasia (IH) and restenosis can compromise the medium-and-long term effects of the CABG. This problem can be correlated with the geometric configuration and hemodynamics of the bypass graft. A novel geometric configuration was proposed for the CABG with two symmetrically implanted grafts for the purpose of improving the hemodynamics. Physiological blood flows in two models of bypass grafts were simulated using numerical methods. One model was for the conventional bypass configuration with a single graft (1-way model); the other model was for the proposed bypass configuration with two grafts (2-way model). The temporal and spatial distributions of hemodynamics, such as flow patterns and Wall Shear Stress (WSS) in the vicinity of the distal anastomoses, were analyzed and compared. Calculation results showed that the 2-way model possessed favorable hemodynamics with uniform longitudinal flow patterns and WSS distributions, which could decrease the probability of restenosis and improve the effect of the surgical treatment. Concerning the limitations of the 2-way bypass grafts, it is necessary to perform animal experiments to verify the viability of this novel idea for the CABG.  相似文献   

11.
BACKGROUND: Intimal hyperplastic thickening (IHT) is a frequent cause of prosthetic bypass graft failure. Induction and progression of IHT is thought to involve a number of mechanisms related to variation in the flow field, injury and the prosthetic nature of the conduit. This study was designed to examine the relative contribution of wall shear stress and injury to the induction of IHT at defined regions of experimental end-to-side prosthetic anastomoses. METHODS AND RESULTS: The distribution of IHT was determined at the distal end-to-side anastomosis of seven canine Iliofemoral PTFE grafts after 12 weeks of implantation. An upscaled transparent model was constructed using the in vivo anastomotic geometry, and wall shear stress was determined at 24 axial locations from laser Doppler anemometry measurements of the near wall velocity under conditions of pulsatile flow similar to that present in vivo. The distribution of IHT at the end-to-side PTFE graft was determined using computer assisted morphometry. IHT involving the native artery ranged from 0.0+/-0.1 mm to 0.05+/-0.03 mm. A greater amount of IHT was found on the graft hood (PTFE) and ranged from 0.09+/-0.06 to 0.24+/-0.06 mm. Nonlinear multivariable logistic analysis was used to model IHT as a function of the reciprocal of wall shear stress, distance from the suture line, and vascular conduit type (i.e. PTFE versus host artery). Vascular conduit type and distance from the suture line independently contributed to IHT. An inverse correlation between wall shear stress and IHT was found only for those regions located on the juxta-anastomotic PTFE graft. CONCLUSIONS: The data are consistent with a model of intimal thickening in which the intimal hyperplastic pannus migrating from the suture line was enhanced by reduced levels of wall shear stress at the PTFE graft/host artery interface. Such hemodynamic modulation of injury induced IHT was absent at the neighboring artery wall.  相似文献   

12.
We present an experimental and computational investigation of time-varying flow in an idealized fully occluded 45 degrees distal end-to-side anastomosis. Two geometric configurations are assessed, one where the centerlines of host and bypass vessels lie within a plane, and one where the bypass vessel is deformed out of the plane of symmetry, respectively, termed planar and non-planar. Flow experiments were conducted by magnetic resonance imaging in rigid wall models and computations were performed using a high order spectral/hp algorithm. Results indicate a significant change in the spatial distribution of wall shear stress and a reduction of the time-averaged peak wall shear stress magnitude by 10% in the non-planar model as compared to the planar configuration. In the planar geometry the stagnation point follows a straight-line path along the host artery bed with a path length of 0.8 diameters. By contrast in the non-planar case the stagnation point oscillates about a center that is located off the symmetry plane intersection with the host artery bed wall, and follows a parabolic path with a 0.7 diameter longitudinal and 0.5 diameter transverse excursion. A definition of the oscillatory shear index (OSI) is introduced that varies between 0 and 0.5 and that accounts for a continuous range of wall shear stress vector angles. In both models, regions of elevated oscillatory shear were spatially associated with regions of separated or oscillating stagnation point flow. The mean oscillatory shear magnitude (considering sites where OSI>0.1) in the non-planar geometry was reduced by 22% as compared to the planar configuration. These changes in the dynamic behavior of the stagnation point and the oscillatory shear distribution introduced by out-of-plane graft curvature may influence the localization of vessel wall sites exposed to physiologically unfavorable flow conditions.  相似文献   

13.

Purpose  

Coronary artery bypass graft (CABG) surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences in the patency rates of the two types of anastomosis. The purpose of this paper is to non-invasively quantify hemodynamic parameters, such as mass flow and wall shear stress (WSS), in end-to-side and side-to-side anastomoses of patients with CABG using computational fluid dynamics (CFD).  相似文献   

14.
Arterio-venous grafts (AVGs), the second best option as long-term vascular access for hemodialysis, face major issues of stenosis mainly due to development of intimal hyperplasia at the venous anastomosis which is linked to unfavorable hemodynamic conditions. We have investigated computationally the utility of a coupled sequential venous anastomotic design to replace conventional end-to-side (ETS) venous anastomosis, in order to improve the hemodynamic environment and consequently enhance the patency of AVGs. Two complete vascular access models with the conventional and the proposed venous anastomosis configurations were constructed. Three-dimensional, pulsatile blood flow through the models was simulated, and wall shear stress (WSS)-based hemodynamic parameters were calculated and compared between the two models. Simulation results demonstrated that the proposed anastomotic design provides: (i) a more uniform and smooth flow at the ETS anastomosis, without flow impingement and stagnation point on the artery bed and vortex formation in the heel region of the ETS anastomosis; (ii) more uniform distribution of WSS and substantially lower WSS gradients on the venous wall; and (iii) a spare route for the blood flow to the vein, to avoid re-operation in case of stenosis. The distinctive hemodynamic advantages observed in the proposed anastomotic design can enhance the patency of AVGs.  相似文献   

15.
The development of intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, involving the incorporation of a small section of vein (vein cuff) into the distal anastomosis of PTFE grafts, results in an altered distribution of intimal hyperplasia and improved graft patency rates, especially for below-knee grafts. Numerical simulations have been conducted under physiological conditions to identify the flow behaviour in a typical cuffed bypass model and to determine whether the improved performance of the cuffed system can be accounted for by haemodynamic factors. The flow patterns at the cuffed anastomosis are significantly different to those at the conventional end-to-side anastomosis. In the former case, the flow is characterised by an expansive, low momentum recirculation within the cuff. Separation occurs at the graft heel, and at the cuff toe as the blood enters the recipient artery. Wall shear stresses in the vicinity of the cuff heel are low, but high shear stresses and large spatial gradients in the shearing force act on the artery floor during systole. In contrast, a less disturbed flow prevails and the floor shear stress distribution is less adverse in the conventional model. In conclusion, aspects of the anastomotic haemodynamics are worsened when the cuff is employed. The benefits associated with the cuffed grafts may be related primarily to the presence of venous material at the anastomosis. Therefore, caution is advised with regard to the use of PTFE grafts, pre-shaped to resemble a cuffed geometry.  相似文献   

16.
Unnatural temporal and spatial distributions of wall shear stress in the anastomosis of distal bypass grafts have been identified as possible factors in the development of anastomotic intimal hyperplasia in these grafts. Distal bypass graft anastomoses with an autologus vein cuff (a Miller cuff) interposed between the graft and artery have been shown to alleviate the effects of intimal hyperplasia. In this study, pulsatile flow through models of a standard end-to-side anastomosis and a Miller cuff anastomosis are computed and the resulting wall shear stress and pressure distributions analysed. The results are inconclusive, and could be taken to suggest that the unnatural distributions of shear stress that do occur along the anastomosis floor may not be particularly important in the development of intimal hyperplasia. However, it seems more likely that the positive effects of the biological and material properties of the vein cuff, which are not considered in this study, somehow outweigh the negative effects of the shear stress distributions predicted to occur on the floor of the Miller-cuff graft.  相似文献   

17.

Unnatural temporal and spatial distributions of wall shear stress in the anastomosis of distal bypass grafts have been identified as possible factors in the development of anastomotic intimal hyperplasia in these grafts. Distal bypass graft anastomoses with an autologus vein cuff (a Miller cuff) interposed between the graft and artery have been shown to alleviate the effects of intimal hyperplasia. In this study, pulsatile flow through models of a standard end-to-side anastomosis and a Miller cuff anastomosis are computed and the resulting wall shear stress and pressure distributions analysed. The results are inconclusive, and could be taken to suggest that the unnatural distributions of shear stress that do occur along the anastomosis floor may not be particularly important in the development of intimal hyperplasia. However, it seems more likely that the positive effects of the biological and material properties of the vein cuff, which are not considered in this study, somehow outweigh the negative effects of the shear stress distributions predicted to occur on the floor of the Miller-cuff graft.  相似文献   

18.
We hypothesize that after implantation the much elevated water filtration rate of venous grafts may cause aggravated concentration polarization of low density lipoproteins (LDLs), in turn lead to the accelerated atherogenesis of the grafts. To verify the hypothesis, we numerically simulated the transport of LDLs in various models of arterial bypasses with different grafts (veins or arteries) and geometrical configurations. The results showed that the venous grafts might endure abnormally high lipid infiltration/accumulation within the vessel wall due to severely elevated luminal surface LDL concentration. When compared to the conventional bypass models, the S-type bypass had the lowest luminal surface LDL concentration along its host artery floor, but the highest degree of risk to develop atherosclerotic lesions in its venous graft. Among the three conventional bypass models, the one with 30° anastomosis had the lowest risk to develop atherosclerosis in the venous graft. In conclusion, when compared with the bypass models with arterial grafts, the venous bypass models had rather high levels of LDL concentration polarization (cw) in the vein grafts, especially at the early stages of implantation. This might result in high infiltration/accumulation of LDLs within the walls of the venous grafts, leading to a fast genesis/development of atherosclerosis there.  相似文献   

19.
This study employed particle image velocimetry (PIV) to validate a numerical model in a complementary approach to quantify hemodynamic factors in distal coronary anastomoses and to gain more insights on their relationship with anastomotic geometry. Instantaneous flow fields and wall shear stresses (WSS) were obtained from PIV measurement in a modified life-size silastic anastomosis model adapted from a conventional geometry by incorporating a smooth graft-artery transition. The results were compared with those predicted by a concurrent numerical model. The numerical method was then used to calculate cycle-averaged WSS (WSS(cyc)) and spatial wall shear stress gradient (SWSSG), two critical hemodynamic factors in the pathogenesis of intimal thickening (IT), to compare the conventional and modified geometries. Excellent qualitative agreement and satisfactory quantitative agreement with averaged normalized error in WSS between 0.8% and 8.9% were achieved between the PIV experiment and numerical model. Compared to the conventional geometry, the modified geometry produces a more uniform WSS(cyc) distribution eliminating both high and low WSS(cyc) around the toe, critical in avoiding IT. Peak SWSSG on the artery floor of the modified model is less than one-half that in the conventional case, and high SWSSG at the toe is eliminated. The validated numerical model is useful for modeling unsteady coronary anastomotic flows and elucidating the significance of geometry regulated hemodynamics. The results suggest the clinical relevance of constructing smooth graft-artery transition in distal coronary anastomoses to improve their hemodynamic performance.  相似文献   

20.
Stent can cause flow disturbances on the endothelium and compliance mismatch and increased stress on the vessel wall. These effects can cause low wall shear stress (WSS), high wall shear stress gradient (WSSG), oscillatory shear index (OSI), and circumferential wall stress (CWS), which may promote neointimal hyperplasia (IH). The hypothesis is that stent-induced abnormal fluid and solid mechanics contribute to IH. To vary the range of WSS, WSSG, OSI, and CWS, we intentionally mismatched the size of stents to that of the vessel lumen. Stents were implanted in coronary arteries of 10 swine. Intravascular ultrasound (IVUS) was used to size the coronary arteries and stents. After 4 wk of stent implantation, IVUS was performed again to determine the extent of IH. In conjunction, computational models of actual stents, the artery, and non-Newtonian blood were created in a computer simulation to yield the distribution of WSS, WSSG, OSI, and CWS in the stented vessel wall. An inverse relation (R(2) = 0.59, P < 0.005) between WSS and IH was found based on a linear regression analysis. Linear relations between WSSG, OSI, and IH were observed (R(2) = 0.48 and 0.50, respectively, P < 0.005). A linear relation (R(2) = 0.58, P < 0.005) between CWS and IH was also found. More statistically significant linear relations between the ratio of CWS to WSS (CWS/WSS), the products CWS × WSSG and CWS × OSI, and IH were observed (R(2) = 0.67, 0.54, and 0.56, respectively, P < 0.005), suggesting that both fluid and solid mechanics influence the extent of IH. Stents create endothelial flow disturbances and intramural wall stress concentrations, which correlate with the extent of IH formation, and these effects were exaggerated with mismatch of stent/vessel size. These findings reveal the importance of reliable vessel and stent sizing to improve the mechanics on the vessel wall and minimize IH.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号