首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Vos EA 《Theriogenology》1996,46(2):211-231
Both free and conjugated fecal estrogens were surveyed in sows by means of RIA's after extraction and column chromatography. Six different RIA's were performed using the same fecal suspension. Based on differences in concentration in feces from 6 pregnant and 4 nonpregnant sows, estrone (E1) was selected for the development of a homologous, competitive ELISA for pregnancy diagnosis purposes. Polyclonal antibodies were raised against 6-keto-E1-carboxymethyloxime coupled to BSA. Biotinylated E1 was used as the competitive agent and was detected with a streptavidin-peroxidase conjugate. Tetramethylbenzidine was used as chromogen. Validation of this direct, easy to perform ELISA showed satisfactory specificity, accuracy, precision and sensitivity. Comparison of the assay with a validated RIA (including extraction and column chromatography) resulted in a linear regression equation of ELISA = 0.88 RIA - 0.72 (r = 0.95; n = 24 fecal samples). The E1 values in feces from 11 pregnant sows during the first 40 d of gestation compared with values from 10 nonpregnant sows showed significant differences between Days 23 and 35 of pregnancy (P < 0.05). The highly significant difference in E1 concentrations (P < 0.0012) between Days 27 and 30 in particular offers promise for pregnancy diagnosis.  相似文献   

2.
A direct, simple and highly specific radioimmunoassay for corticosterone has been developed. The assay does not require preliminary solvent extraction of the sample or any chromatographic step. The assay utilises a highly specific antibody raised in rabbits against corticosterone-3-(0-carboxymethyl)-oxime-BSA immunogen and gamma-labeled corticosterone of high specific activity. An excellent correlation was obtained between results of the direct assay and those measured after paper chromatography (r=0.99, P<0.001). The coefficients of variation for intra-assay and inter-assay determinations of samples from normal and high plasma pools were 4.6–6.2% and 6.4–8.2% respectively. The minimum limit of detection was 5 pg/assay tube (0.1ng/ml). The assay has been applied to assess plasma corticosterone levels in various physiological and pathophysiological studies. It is extremely practical to the extent that a single technician can assay up to 1000 samples in a working week. Finally, the direct assay has been validated and employed for in vitro adrenal superfusion studies using either rat or human adrenal cells. The large numbers of samples produced by these studies would have exceeded the capacity of earlier radioimmunoassays requiring initial extraction and chromatography.  相似文献   

3.
Since correct assessment of testicular function and androgenic status in humans requires multiple sampling, a sensitive and accurate radioimmunoassay (RIA) of testosterone (T) was established for male and female saliva samples. This easily collected biological fluid, which contains nonprotein-bound T, may represent an attractive alternative or a complement to total plasma T assays. In saliva samples from 5 normal males, a clear circadian rhythm was observed, and morning concentrations (135 +/- 31 pg/ml) were significantly higher (p less than 0.02) than evening samples (85 +/- 23 pg/ml). In 11 normal females, morning saliva levels were 12.8 +/- 1.8 pg/ml. The levels of T in male saliva, in response to both exogenous T administration (100 mg i.m.) and HCG stimulation (2 X 2,000 IU i.m.), accurately reflected the changes observed in plasma T, and the magnitude of increase in T levels was clearly greater in saliva than in plasma samples during the intramuscular administration of the long-acting T preparation. In males, significant correlations were observed between salivary and plasma T concentrations in morning samples (r = 0.61, p less than 0.01), following HCG stimulation (r = 0.89, p less than 0.05) and during T administration (r = 0.87, p less than 0.05). In women, the correlation at 8 a.m. was also significant (r = 0.82, p less than 0.05).  相似文献   

4.
S K Ghosh 《Steroids》1988,52(1-2):1-14
The development of highly specific monoclonal antibodies to estriol and a nonisotopic immunoassay (EIA) for unconjugated estriol based on the use of these monoclonal antibodies have been described. The monoclonal antibodies show little cross reactivity with other steroids and steroid conjugates and can be used directly in immunoassays without any purification. The EIA described here can be performed in 96-well microtiter plates or polystyrene tubes that have been coated with estriol-bovine serum albumin conjugate. In this assay, estriol in the standard or clinical samples (serum or saliva) competes with the immobilized steroid on the plate or the tube for binding with the antibody. The assay shows good agreement with radioimmunoassay (RIA) and is highly sensitive and reliable. Since no prior processing or extraction of the clinical samples is necessary, the method is potentially applicable for routine use in fetal monitoring as well as in a steroid laboratory.  相似文献   

5.
Blood and urine samples collected from 12 mares at frequent intervals from 25 to 210 d of pregnancy were analyzed for equine chorionic gonadotropin (eCG). Blood and urine samples were collected daily through two consecutive ovulatory periods from five cyclic mares for comparative purposes. Separate radioimmunoassays (RIA) were developed to detect eCG in the urine and plasma. A simple and quick commercial dipstick enzyme-linked immunospecific assay (ELISA), developed for eCG in the blood, was also utilized in this study to detect eCG in the urine. In the 12 pregnant mares, eCG concentrations in both the plasma and urine as detected by RIA rose significantly on Day 40, peaked by Day 60 and slowly dropped to low levels by Day 200. The dipstick ELISA appeared more reliable for eCG in the plasma than in the urine of the five pregnant mares tested. However, on peak days (50 to 60), both the plasma and urine tested positive in all five mares. Similar eCG profiles were observed when urine samples from seven of the mares were assayed in the dipstick ELISA and RIA. The highest percentage of mares (86%) were positive for eCG by ELISA between Days 65 and 85. The highest concentration of eCG in the urine as detected by RIA was observed between Days 55 and 90. ECG-like immunoactivity was not detected by the ELISA in the urine of cyclic mares, but the RIA showed variable patterns with increases in immunoactivity that could not be correlated with physiological events. In summary, eCG in urine follows a similar profile as the eCG in plasma of mares during their first trimester of pregnancy.  相似文献   

6.
To test the hypothesis that relaxin may play a role in the fetal abnormalities associated with pregnancy in type 1 diabetic women, we previously compared gestational relaxin concentrations in diabetic and clinically normal women using a porcine relaxin radioimmunoassay (RIA): Serum immunoactive relaxin was significantly (P < 0.001) elevated in the diabetic women. To confirm and extend this work in a larger group of subjects, we have now used an enzyme-linked immunosorbent assay (ELISA) specific for human H2 relaxin (the normal human gene product) to determine immunoactive serum relaxin concentrations in serial samples from 61 Type 1 diabetic and 21 normal pregnant women. Samples from 22 of the diabetic and nine of the normal women were also directly compared in the porcine relaxin RIA. ELISA-determined serum relaxin was higher (P < 0.001) at 24 and 36 weeks of pregnancy in type 1 diabetic women than in controls, confirming previous findings. However, the geometric mean increase in immunoactive relaxin concentration in identical samples from pregnant diabetic women over that of controls was significantly greater with the RIA than with the ELISA (271% vs 44%; P < 0.001). To investigate this discrepancy, the specificity and epitope selectivity of the RIA and the ELISA were compared using several synthetic polypeptides, including human relaxins H1 and H2, and relaxin and insulin derivatives. Both assays showed great specificity, but the porcine RIA selectively identified the epitopes of the receptor-binding domain of the relaxin B chain and cross-reacted strongly with H1 and H2 relaxins. In contrast, only the H2 peptide was detected by the ELISA antiserum. Therefore, the marked discrepancy between the RIA and the ELISA could be due to the presence in the diabetic samples of another relaxin-like molecule in addition to the normal H2 relaxin. The biological consequences of elevated serum relaxin in diabetic pregnancy remain to be elucidated.  相似文献   

7.
Although recent data for several species of primate, including human and marmoset, indicate that the corpus luteum secretes high levels of radioimmunoassayable inhibin, the nature of the immunoreactive (ir) inhibin detected has not been established. In this study, plasma ir-inhibin levels during the ovarian cycle of the marmoset (n = 12 animals) were measured by alpha-subunit-directed inhibin RIA, and values were compared with those estimated by a recently developed two-site immunoradiometric assay (IRMA) specific for inhibin alpha-beta dimer. Consistent with earlier data, plasma levels of ir-inhibin measured by RIA (overall mean value 133 +/- 7 ng/ml; n = 171) reached values 4-fold higher (p less than 0.001) during the luteal phase (222 +/- 20 ng/ml) than during the follicular phase (58 +/- 8 ng/ml), being directly correlated with plasma progesterone levels (r = 0.65; p less than 0.001). In contrast, plasma ir-inhibin levels estimated by IRMA were substantially lower than those measured by RIA (overall mean value 9.62 +/- 1.08 ng/ml; n = 171) and did not vary significantly during the cycle. Administration of a luteolytic dose of cloprostenol during the late luteal phase/early pregnancy led to an abrupt fall in plasma concentrations of progesterone (95%) and alpha-inhibin measured by RIA (82%), whereas dimeric inhibin levels remained unchanged. Analysis of marmoset luteal extracts (n = 5) by RIA, IRMA, and inhibin bioassay yielded inhibin estimates of 102.6 +/- 21.0, 0.632 +/- 0.103, and less than 2.0 ng/mg, respectively, thus confirming that only a very small proportion of the inhibin produced was dimeric (i.e., bioactive) in nature.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
This study was undertaken to assess the nature of somatomedin-C (SM-C) in baboon (Papio cynocephalus) blood and to compare various methods for estimating SM-C concentrations. Parallel dose-response curves were obtained with normal baboon serum, normal human serum, and purified SM-C. Recovery of purified SM-C added to baboon serum over a wide dosage range (n = 17) was 111 ± 12%, with slightly better recovery at higher potencies. Chromatography of normal baboon serum on Sephadex G-200 at neutral pH produced a profile similar to that observed in the human, as did samples chromatographed on Sephadex G-50 in acid. Although the SM-C content in acid chromatographed plasma was approximately 2.5 times higher than in native unprocessed plasma, there was excellent correlation between the values (r = 0.9143, p < 0.0001). The SM-C in baboon plasma which had been preincubated with glycine HCl was approximately twice that of unprocessed plasma, but the correlation between the two methods was excellent (r = 0.9593, p < 0.0001). The correlation between values obtained after simple acid-ethanol extraction and those observed in unextracted plasma were also significant (r = 0.7689, p < 0.0001). Following a series of four injections of human growth hormone (hGH) to a normal baboon, plasma SM-C rose approximately sevenfold above the initial concentration and returned to basal levels five days after the final injection. These studies show that although the radioimmunoassay (RIA) for SM-C in unprocessed baboon plasma does not measure all of the SM-C present, it provides a reliable index of the total SM-C concentration and reflects GH status in the baboon.  相似文献   

9.
A rapid, sensitive and highly specific radioimmunoassay (RIA) for 11-deoxycortisol has been developed and used for the measurement of serum concentrations.Antisera were raised using 11-deoxycortisol-3-carboxymethyloxime-bovine serum albumin as immunogen and showed minimal cross reaction with related steroids. 11-Deoxycortisol-3-carboxymethyloxime was coupled to 125I-iodohistamine to produce a labelled antigen of high specific activity (s.a. 680 Ci/mmol). The assay was performed for 1h at room temperature and pH 4.Results were correlated with those after extraction, high pressure liquid chromatography and RIA of serum samples (y = 0.78x + 36.9; r = 0.97, p<0.001). The accuracy of the method was satisfactory (y = 1.00x ? 0.61; r = 0.95; p<0.001). Assay sensitivity was 0.3 nmol/1. 11-Deoxycortisol concentrations in normal subjects at 09.00h were 26 ? 46 nmol/1 (37.2 ± 5.7; x ± 1 S.D.).The assay should facilitate the investigation of patients with possible abnormalities of adrenocortical function.  相似文献   

10.
A monoclonal antibody-based direct binding enzyme-linked immunosorbent assay (ELISA) for apoprotein (apo) B-100 has been developed for use as a reference method. The assay uses the two well-characterized monoclonal antibodies, MB24 and MB47. MB47, which recognizes an epitope at the low density lipoprotein (LDL) receptor-binding domain of apoB and is specific for apoB-100, is bound to the microtiter plate as the capture antibody. MB24, which binds an epitope in the amino terminal half of the apoB-100 and identifies both apoB-100 and apoB-48, is conjugated to horseradish peroxidase and is utilized as the indicating antibody. The assay was calibrated with LDL (d 1.030-1.050 g/ml) and the LDL protein was determined by a sodium dodecyl sulfate (SDS) Lowry procedure. The working range of the assay is 0.25-1.25 micrograms/ml. Optimal dilution of whole plasma was found to be 1:2000. In the assay, MB47 bound approximately 97% of the apoB in all low density lipoprotein, and greater than 90% of the apoB in the majority of very low density lipoprotein preparations. Small dense LDL from subjects with familial combined hyperlipidemia (FCHL) and large bouyant LDL from subjects with familial hypercholesterolemia (FH) exhibited binding properties similar to LDL from healthy normolipidemic subjects when tested in the reference ELISA. The intra- and interassay coefficients of variation averaged 2.5% and 6.0%, respectively. Plasma B-100 levels were not influenced by freezing and thawing or storage at 4 degrees C for up to 3 weeks or storage at -70 degrees C for up to 11 months. Excellent agreement was obtained between the reference ELISA and a polyclonal RIA which measures total apoB (r = 0.93, n = 105, mean ELISA B-100 value = 100 mg/dl, mean RIA value = 101 mg/dl, Sy = 9.6). Reference ELISA B-100 values of samples pretreated with bacterial lipase were not significantly increased in most samples with plasma triglyceride levels below 600 mg/dl. To help reduce the large among-laboratories variability of apoB measurements, we recommend that this candidate reference direct binding ELISA be used to assign apoB target values to apoB reference pools.  相似文献   

11.
A stable isotope dilution gas chromatography-mass spectrometry (GC-MS) assay for the trace level determination of estriol in human plasma is described. Negative ion chemical ionization (NICI) MS is used for highly specific detection. The method involves derivatization of the phenolic hydroxyl to the pentafluorobenzyl ether derivative and subsequent reaction of the remaining hydroxyls with heptafluorobutyric anhydride. This derivative allows detection of the strikingly abundant phenolate ion under NICI conditions. [2,4,17beta]-2H(3)-labeled estriol was used as an internal standard. For high-level measurements (>313 ng/l) plasma was directly derivatized by extractive alkylation followed by heptafluorobutylation prior to analysis. A rapid and simple sample work up procedure was elaborated for trace level determinations (>5 ng/l plasma) using solid-phase extraction on C(18) with an absolute recovery of 92.9%. For low-level measurements, the calibration curve was linear in the range of 5 to 625 ng/l (r=0.99993). Inter-assay analytical precisions (RSDs) were 1.29, 2.30 and 2.89% at 39, 156 and 650 ng/l plasma, respectively. For high-level measurements, calibration curve linearity was observed in the range of 0.313 to 20 microg/l (r=0.99998). Inter-assay analytical precisions (RSDs) were 5.17, 1.92, 2.57 and 2.74% at 0.313, 0.625, 2.5 and 10 microg/l plasma, respectively. Postmenopausal plasma was used for spiked plasma samples. Sensitivity and specificity of the presented method allows adequate determination of estriol in human plasma samples.  相似文献   

12.
A highly sensitive and specific second antibody enzymeimmunoassay (EIA) on microtiterplates for oxytocin determination in bovine plasma using the biotin–streptavidin amplification system was developed. Biotin was coupled to oxytocin and used to bridge between streptavidin-peroxidase and the immobilized oxytocin antiserum in the competitive assay. The assay was carried out directly in 200 μl of bovine plasma. Oxytocin standards prepared in hormone-free plasma were used. The sensitivity of the assay was 0.25 pg/well which corresponded to 1.25 pg/ml plasma; the 50% relative binding was seen at 2.8 pg/well. Plasma volumes for the assay ranging from 50 to 200 μl did not influence the shape of the oxytocin standard curve; however a distinct drop in the OD450 was observed with higher plasma volumes. The oxytocin antiserum used in the assay showed no significant cross-reaction with other octapeptides tested. The assay was compared with a radioimmunoassay (RIA) procedure employing prior solvent extraction of plasma samples. The oxytocin concentrations assayed by EIA and RIA in plasma samples obtained from four cows before, during and after milking were highly correlated and very similar (r=0.97). Hence the assay developed offers an attractive alternative to the RIA since no prior laborious plasma extraction is needed. Further, the assay has the distinct advantage of being non-radioactive in nature.  相似文献   

13.
Cooke DG  Binnie JE  Blackwell LF 《Steroids》2007,72(6-7):580-591
A direct enzyme linked immunosorbent assay (ELISA) system has been optimized as a reference method for the measurement of first statistically significant rises in estrone glucuronide excretion rates in human urine by analysing samples pre-diluted at the time of the collection by the women subjects to a constant urine production rate of 150 mL/h. Validation was achieved by correlation of the individual menstrual cycle profiles with the corresponding estrone glucuronide excretion rates determined by radioimmunoassay (RIA) on the same urine samples for a total of 221 samples from nine cycles. The pre-dilution procedure removed random variations due to fluctuations in the daily rate of urine excretion and minimized between sample matrix effects. When the ELISA data were correlated with the RIA data, Deming regression gave a slope of 1.20+/-0.03 and an intercept of 4.6+/-1.8 nmol/24h (r=0.944) and a random experimental error of 14.2 nmol/24h. The major difference in the measurements was a proportional error of 20%, which was present in either the ELISA or RIA methods or in both. Comparison of the standard normal variate transformation of the ELISA and RIA data gave hormonal profiles of the individual menstrual cycles (N=9) that overlapped almost perfectly. Statistically significant rises or falls in the magnitude of the excretion rate in one profile were mirrored faithfully in the other.  相似文献   

14.
Analysis of laboratory samples from chronic renal failure (CRF) and end stage renal disease (ESRD) patients can be problematic. Current HPLC and RIA methods for the determination of 25 OH Vitamin D involve sample extraction. However, the differences between a normal and CRF or ESRD matrix can lead to interference or inaccuracy in non-extracted, automated methods now available. The objective of this study was to assess the accuracy of the non-extracted LIAISON 25 OH Vitamin D assay in the analysis of CRF and ESRD samples as compared against RIA as reference. Samples were collected from regional reference laboratories and analyzed in both the LIAISON 25 OH Vitamin D assay and the DiaSorin 25 OH Vitamin D RIA. By Student's t test, no significant difference was observed between the RIA values and the LIAISON values (P = 0.07 CRF; P = 0.28 ESRD). The linear regression analysis resulted in the equations: CRF: LIAISON = 0.91 (RIA) + 0.6; r = 0.82 and ESRD: LIAISON = 0.93 (RIA) - 0.6; r = 0.78. From these data we conclude that the LIAISON 25 OH Vitamin D assay correctly assesses the 25 OH Vitamin D status of CRF and ESRD patients.  相似文献   

15.
Atrial natriuretic factor in human plasma   总被引:4,自引:0,他引:4  
A reproducible and sensitive radioimmunoassay (RIA) was developed to measure ANF in human plasma. Immunoreactive ANF was extracted from plasma with Sep-Pak cartridges, using 0.2% ammonium acetate (pH 4) with acetonitrile. The sensitivity of the assay was 3.9 pg/ml. The coefficient of variance for inter-assay and intra-assay was 16.8% and 6.8%, respectively. In normal healthy subjects (n = 67), ANF content was 11.9 +/- 1.3 pg/ml (mean +/- SEM). Significantly-higher ANF concentrations were found in proximal coronary sinus blood, being 6 to 37 times greater than in the peripheral circulation. Comparison of the prior extraction method with direct RIA revealed a good correlation (r = 91) in samples containing higher than 100 pg/ml ANF. No correlation was observed with lower values. The elution profiles of reverse-phase HPLC of peripheral and coronary sinus plasma extracts were similar but somewhat complex, with the main immunoreactive peak corresponding to a low-molecular-weight peptide.  相似文献   

16.
To investigate which matrix metalloproteinases (MMPs) are more likely to be involved in the angiogenic process in proliferative diabetic retinopathy (PDR), we measured the levels of MMPs in the vitreous fluid from patients with PDR and controls and correlated these levels with the levels of vascular endothelial growth factor (VEGF). Vitreous samples from 32 PDR and 24 nondiabetic patients were studied by mosaic multiplex MMPs enzyme-linked immunosorbent assay (ELISA), single ELISA, Western blot and zymography analysis. Epiretinal membranes from 11 patients with PDR were studied by immunohistochemistry. MMP-8 and MMP-13 were not detected. ELISA, Western blot and gelatin ymography assays revealed significant increases in the expression levels of MMP-1, MMP-7, MMP-9 and VEGF in vitreous samples from PDR patients compared to nondiabetic controls, whereas MMP-2 and MMP-3 were not upregulated in vitreous samples from PDR patients. Significant correlations existed between ELISA and zymography assays for the quantitation of MMP-2 (r=0.407; p=0.039) and MMP-9 (r=0.711; p<0.001). Significant correlations were observed between levels of VEGF and levels of MMP-1 (r=0.845; P<0.001) and MMP-9 (r=0.775; p<0.001), and between levels of MMP-1 and MMP-9 (r=0.857; p<0.001). In epiretinal membranes, cytoplasmic immunoreactivity for MMP-9 was present in vascular endothelial cells and stromal monocytes/macrophages and neutrophils. Our findings suggest that among the MMPs measured, MMP-1 and MMP-9 may contribute to the angiogenic switch in PDR.  相似文献   

17.
A practical method was developed for enzyme-immunoassay of serum estriol, with alkaline-phosphatase as a marker enzyme. Alkaline-phosphatase was conjugated with estriol-6-(O-carboxymethyl) oxime using water soluble carbodiimide. The estriol-alkaline-phosphatase complex, which has both enzyme activity and capacity to bind anti-estriol serum, was obtained by Sephadex G-200 gel filtration. This complex, which was stable for at least 3 months at 4 degrees C, was used as enzyme-labelled estriol. Anti-estriol serum raised against estriol-6-(O-carboxymethyl) oxime bovine serum albumin was employed. "Bound and free" estriol were separated by the double antibody method. A linear relation was obtained between estriol concentration and antibody-bound alkaline-phosphatase activity in the range of 0.2-100 ng estriol/ml. In this assay system, cross-reactivity with other steroids was negligible under physiological conditions, and endogenous alkaline-phosphatase, which increases during the late pregnancy, caused no interference. The coefficients of variation were 3.3-14.2% (within assays), and less than 22% (between assays), and the mean recovery rate was 77.5%. Serum estriol values determined by the present method correlated well with those determined by radioimmunoassay (r=0.90 for total estriol; r=0.98 for free estriol). The present method of enzyme-immunoassay is suitable for measurement of serum estriol during pregnancy.  相似文献   

18.
Lithium carbonate is used in the treatment of both psychiatric and nonpsychiatric disorders. The aim of this study was to explore the relationship between serum lithium, salivary lithium, and urinary lithium. Blood, saliva, and urine samples were collected from 50 patients, and estimation of serum, salivary, and urine lithium was done using an atomic absorption spectrophotometer. Mean serum lithium was 0.75 ± 0.25 mEq/L, mean salivary lithium was 1.91 ± 0.80 mEq/L, and mean urine lithium was 7.16 ± 4.84 mEq/L. A significant direct correlation was found between serum lithium and salivary lithium (r = 0.695, p < 0.001). This correlation was higher in females (r = 0.770, p < 0.001) when compared to males (r = 0.665, p < 0.001). Even though a significant correlation was found between serum and salivary lithium levels, more studies are needed in this domain to establish salivary therapeutic monitoring as a feasible option for patients on lithium carbonate therapy.  相似文献   

19.
Exosomal proteins are emerging as relevant diagnostic and prognostic biomarkers for cancer. This study was aimed at illustrating the clinical significance of exosomal Copine III (CPNE3) purified from the plasma of colorectal cancer (CRC) patients. The CPNE3 expression levels in CRC tissues were analyzed by real-time PCR, western blot, and immunohistochemistry. Plasma exosomes were isolated to examine the CPNE3 level using ELISA. Pearson’s correlation analysis was performed to investigate the CPNE3 levels between CRC tissues and matched plasma samples. Receiver operating characteristic curve analysis was developed to measure the diagnostic performance of exosomal CPNE3. The Kaplan–Meier method and Cox's proportional hazards model were utilized to determine statistical differences in survival times. CPNE3 showed increased expressions in the CRC tissues. A moderately significant correlation was found between CPNE3 expression in CRC tissues by immunohistochemistry and matched serum exosomal CPNE3 expression by ELISA (r = 0.645,(r = 0.645, p < 0.001). < 0.001). Exosomal CPNE3 yielded a sensitivity of 67.5% and a specificity of 84.4% in CRC at the cutoff value of 0.143 pg per 1ug1 ug exosome. Combined data from carcinoembryonic antigen and exosomal CPNE3 achieved 84.8% sensitivity and 81.2% specificity as a diagnostic tool. CRC patients with lower exosomal CPNE3 levels had substantially better disease-free survival (hazard ratio [HR], 2.9; 95% confidence interval [CI]: 1.3–6.4; p = 0.009) = 0.009) and overall survival (HR, 3.4; 95% CI: 1.2–9.9; p = 0.026) = 0.026) compared with those with higher exosomal CPNE3 levels. Exosomal CPNE3 show potential implications in CRC diagnosis and prognosis.  相似文献   

20.
This study describes the peripheral concentrations of immunoreactive (ir) inhibin, progesterone, and bioactive gonadotrophin during pregnancy in the marmoset monkey, a New World primate. Blood samples were taken every two weeks from six animals from ovulation to parturition. Plasma ir-inhibin concentrations were measured by inhibin α-subunit-directed radioimmunoassay (RIA) and a recently developed two-site immunoradiometric assay (IRMA) which is specific for inhibin αβ dimer. Concentrations of α-inhibin increased (P < 0.001) during early pregnancy to reach a peak on week 12 of pregnancy and showed a positive correlation with bioassayable gonadotrophin concentrations (r = 0.5, n = 64; P < 0.001). The concentrations of both α-inhibin and gonadotrophin showed no further peaks and declined (P < 0.001) to low levels prior to birth. Concentrations of dimeric inhibin were substantially lower than those measured by RIA and did not vary significantly during pregnancy. Progesterone concentrations remained at luteal-phase levels during the first half of pregnancy and increased (P < 0.05) during the second half to reach maximum concentrations just prior to birth. The relationship between α-inhibin, gonadotrophin, and progesterone suggests that the increase in α-inhibin may be luteal in source and under the control of gonadotrophin. The absence of a second increase in α-inhibin later in pregnancy and the finding that lategestation placenta contained very little α-inhibin differs from observations in Old World primates studied and suggests that the placenta may not be a source of inhibin during pregnancy in the marmoset. The finding of high levels of α-inhibin, but not dimeric inhibin, suggests that inhibin-related molecules may have a role other than suppression of pituitary folliclestimulating hormone. © 1994 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号