首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
Culturing cells in a three dimensional hydrogel environment is an important technique for developing constructs for tissue engineering as well as studying cellular responses under various culture conditions in vitro. The three dimensional environment more closely mimics what the cells observe in vivo due to the application of mechanical and chemical stimuli in all dimensions 1. Three-dimensional hydrogels can either be made from synthetic polymers such as PEG-DA 2 and PLGA 3 or a number of naturally occurring proteins such as collagen 4, hyaluronic acid 5 or fibrin 6,7. Hydrogels created from fibrin, a naturally occurring blood clotting protein, can polymerize to form a mesh that is part of the body''s natural wound healing processes 8. Fibrin is cell-degradable and potentially autologous 9, making it an ideal temporary scaffold for tissue engineering.Here we describe in detail the isolation of neonatal cardiomyocytes from three day old rat pups and the preparation of the cells for encapsulation in fibrin hydrogel constructs for tissue engineering. Neonatal myocytes are a common cell source used for in vitro studies in cardiac tissue formation and engineering 4. Fibrin gel is created by mixing fibrinogen with the enzyme thrombin. Thrombin cleaves fibrinopeptides FpA and FpB from fibrinogen, revealing binding sites that interact with other monomers 10. These interactions cause the monomers to self-assemble into fibers that form the hydrogel mesh. Because the timing of this enzymatic reaction can be adjusted by altering the ratio of thrombin to fibrinogen, or the ratio of calcium to thrombin, one can injection mold constructs with a number of different geometries 11,12. Further we can generate alignment of the resulting tissue by how we constrain the gel during culture 13.After culturing the engineered cardiac tissue constructs for two weeks under static conditions, the cardiac cells have begun to remodel the construct and can generate a contraction force under electrical pacing conditions 6. As part of this protocol, we also describe methods for analyzing the tissue engineered myocardium after the culture period including functional analysis of the active force generated by the cardiac muscle construct upon electrical stimulation, as well as methods for determining final cell viability (Live-Dead assay) and immunohistological staining to examine the expression and morphology of typical proteins important for contraction (Myosin Heavy Chain or MHC) and cellular coupling (Connexin 43 or Cx43) between myocytes.  相似文献   

2.
Mechanically induced cell deformations have been shown to influence chondrocyte response in 3D culture. However, the relationship between the mechanical stimulation and cell response is not yet fully understood. In this study a finite element model was developed to investigate cell-matrix interactions under unconfined compression conditions, using a tissue engineered encapsulating hydrogel seeded with chondrocytes. Model predictions of stress and strain distributions within the cell and on the cell boundary were shown to exhibit space-dependent responses that varied with scaffold mechanical properties, the presence of a pericellular matrix (PCM), and the cell size. The simulations predicted that when the cells were initially encapsulated into the hydrogel scaffolds, the cell size hardly affected the magnitude of the stresses and strains that were reaching the encapsulated cells. However, with the inclusion of a PCM layer, larger cells experienced enhanced stresses and strains resulting from the mechanical stimulation. It was also noted that the PCM had a stress shielding effect on the cells in that the peak stresses experienced within the cells during loading were significantly reduced. On the other hand, the PCM caused the stresses at the cell-matrix interface to increase. Based on the model predictions, the PCM modified the spatial stress distribution within and around the encapsulated cells by redirecting the maximum stresses from the periphery of the cells to the cell nucleus. In a tissue engineered cartilage exposed to mechanical loading, the formation of a neo-PCM by encapsulated chondrocytes appears to protect them from initially excessive mechanical loading. Predictive models can thus shed important insight into how chondrocytes remodel their local environment in order to redistribute mechanical signals in tissue engineered constructs.  相似文献   

3.
Chemical and mechanical stimulation, when properly utilized, positively influence both the differentiation of in vitro cultured stem cells and the quality of the deposited extracellular matrix (ECM). This study aimed to find if cell‐free extract from primary tenocytes can positively affect the development of a tissue‐engineered tendon construct, consisting of a human umbilical vein (HUV) seeded with mesenchymal stem cells (MSCs) subjected to cyclical mechanical stimulation. The tenocytic cell‐free extract possesses biological material from tendon cells that could potentially influence MSC tenocytic differentiation and construct development. We demonstrate that the addition of tenocytic extract in statically cultured tendon constructs increases ECM deposition and tendon‐related gene expression of MSCs. The incorporation of mechanical stimulation (2% strain for 30 min/day at 0.5 cycles/min) with tenocytic extract further improved the MSC seeded HUV constructs by increasing cellularity of the construct by 37% and the ultimate tensile strength by 33% compared to the constructs with only mechanical stimulation after 14 days. Furthermore, the addition of mechanical stimulation to the extract supplementation produced longitudinal ECM fibril alignment along with dense connective tissue, reminiscent of natural tendon.  相似文献   

4.
《Organogenesis》2013,9(3):317-322
This commentary discusses the rationale behind our recently reported work entitled “Mimicking isovolumic contraction with combined electromechanical stimulation improves the development of engineered cardiac constructs,” introduces new data supporting our hypothesis, and discusses future applications of our bioreactor system. The ability to stimulate engineered cardiac tissue in a bioreactor system that combines both electrical and mechanical stimulation offers a unique opportunity to simulate the appropriate dynamics between stretch and contraction and model isovolumic contraction in vitro. Our previous study demonstrated that combined electromechanical stimulation that simulated the timing of isovolumic contraction in healthy tissue improved force generation via increased contractile and calcium handling protein expression and improved hypertrophic pathway activation. In new data presented here, we further demonstrate that modification of the timing between electrical and mechanical stimulation to mimic a non-physiological process negatively impacts the functionality of the engineered constructs. We close by exploring the various disease states that have altered timing between the electrical and mechanical stimulation signals as potential future directions for the use of this system.  相似文献   

5.
Summary Previously, we have engineered three-dimensional (3-D) skeletal muscle constructs that generate force and display a myosin heavy-chain (MHC) composition of fetal muscle. The purpose of this study was to evaluate the functional characteristics of 3-D skeletal muscle constructs cocultured with fetal nerve explants. We hypothesized that coculture of muscle constructs with neural cells would produce constructs with increased force and adult MHC isoforms. Following introduction of embryonic spinal cord explants to a layer of confluent muscle cells, the neural tissue integrated with the cultured muscle cells to form 3-D muscle constructs with extensions. Immunohistochemical labeling indicated that the extensions were neural tissue and that the junctions between the nerve extensions and the muscle constructs contained clusters of acetylcholine receptors. Compared to muscles cultured without nerve explants, constructs formed from nerve-muscle coculture showed spontaneous contractions with an increase in frequency and force. Upon field stimulation, both twitch (2-fold) and tetanus (1.7-fold) were greater in the nerve-muscle coculture system. Contractions could be elicited by electrically stimulating the neural extensions, although smaller forces are produced than with field stimulation. Severing the extension eliminated the response to electrical stimulation, excluding field stimulation, as a contributing factor. Nervemuscle constructs showed a tendency to have higher contents of adult and lower contents of fetal MHC isoforms, but the differences were not significant. In conclusion, we have successfully engineered a 3-D nerve-muscle construct that displays functional neuromuscular junctions and can be electrically stimulated to contract via the neural extensions projecting from the construct.  相似文献   

6.
Transplantation of skeletal myoblasts (SMs) has been investigated as a potential cardiac cell therapy approach. SM are available autologously, predetermined for muscular differentiation and resistant to ischemia. Major hurdles for their clinical application are limitations in purity and yield during cell isolation as well as the absence of gap junction expression after differentiation into myotubes. Furthermore, transplanted SMs do not functionally or electrically integrate with the host myocardium. Here, we describe an efficient method for isolating homogeneous SM populations from neonatal mice and demonstrate persistent gap junction expression in an engineered tissue. This method resulted in a yield of 1.4 × 10(8) high-purity SMs (>99% desmin positive) after 10 days in culture from 162.12 ± 11.85 mg muscle tissue. Serum starvation conditions efficiently induced differentiation into spontaneously contracting myotubes that coincided with loss of gap junction expression. For mechanical conditioning, cells were integrated into engineered tissue constructs. SMs within tissue constructs exhibited long term survival, ordered alignment, and a preserved ability to differentiate into contractile myotubes. When the tissue constructs were subjected to passive longitudinal tensile stress, the expression of gap junction and cell adherence proteins was maintained or increased throughout differentiation. Our studies demonstrate that mechanical loading of SMs may provide for improved electromechanical integration within the myocardium, which could lead to more therapeutic opportunities.  相似文献   

7.
In vitro studies have used protein markers to distinguish between myogenic cells isolated from fast and slow skeletal muscles. The protein markers provide some support for the hypothesis that satellite cells from fast and slow muscles are different, but the data are equivocal. To test this hypothesis directly, three-dimensional skeletal muscle constructs were engineered from myogenic cells isolated from fast tibialis anterior (TA) and slow soleus (SOL) muscles of rats and functionality was tested. Time to peak twitch tension (TPT) and half relaxation time (RT1/2) were 30% slower in constructs from the SOL. The slower contraction and relaxation times for the SOL constructs resulted in left shift of the force-frequency curve compared with those from the TA. Western blot analysis showed a 60% greater quantity of fast myosin heavy chain in the TA constructs. 14 days of chronic low-frequency electrical stimulation resulted in a 15% slower TPT and a 14% slower RT1/2, but no change in absolute force production in the TA constructs. In SOL constructs, slow electrical stimulation resulted in an 80% increase in absolute force production with no change in TPT or RT1/2. The addition of cyclosporine A did not prevent the increase in force in SOL constructs after chronic low-frequency electrical stimulation, suggesting that calcineurin is not responsible for the increase in force. We conclude that myogenic cells associated with a slow muscle are imprinted to produce muscle that contracts and relaxes slowly and that calcineurin activity cannot explain the response to a slow pattern of electrical stimulation. tissue engineering; calcineurin; electrical stimulation; engineered muscle; bioreactors  相似文献   

8.
The success of stem cell-based cartilage repair requires that the regenerate tissue reach a stable state. To investigate the long-term stability of tissue engineered cartilage constructs, we assessed the development of compressive mechanical properties of chondrocyte and mesenchymal stem cell (MSC)-laden three dimensional agarose constructs cultured in a well defined chondrogenic in vitro environment through 112 days. Consistent with previous reports, in the presence of TGF-β, chondrocytes outperformed MSCs through day 56, under both free swelling and dynamic culture conditions, with MSC-laden constructs reaching a plateau in mechanical properties between days 28 and 56. Extending cultures through day 112 revealed that MSCs did not simply experience a lag in chondrogenesis, but rather that construct mechanical properties never matched those of chondrocyte-laden constructs. After 56 days, MSC-laden constructs underwent a marked reversal in their growth trajectory, with significant declines in glycosaminoglycan content and mechanical properties. Quantification of viability showed marked differences in cell health between chondrocytes and MSCs throughout the culture period, with MSC-laden construct cell viability falling to very low levels at these extended time points. These results were not dependent on the material environment, as similar findings were observed in a photocrosslinkable hyaluronic acid (HA) hydrogel system that is highly supportive of MSC chondrogenesis. These data suggest that, even within a controlled in vitro environment that is conducive to chondrogenesis, there may be an innate instability in the MSC phenotype that is independent of scaffold composition, and may ultimately limit their application in functional cartilage repair.  相似文献   

9.
The insufficient load-bearing capacity of today’s tissue- engineered (TE) cartilage limits its clinical application. Generally, cartilage TE studies aim to increase the extracellular matrix (ECM) content, as this is thought to determine the load-bearing properties of the cartilage. However, there are apparent inconsistencies in the literature regarding the correlation between ECM content and mechanical properties of TE constructs. In addition to the amount of ECM, the spatial inhomogeneities in ECM distribution at the tissue scale as well as at the cell scale may affect the mechanical properties of TE cartilage. The relative importance of such structural inhomogeneities on mechanical behavior of TE cartilage is unknown. The aim of the present study was, therefore, to theoretically elucidate the influence of these inhomogeneities on the mechanical behavior of chondrocyte-agarose TE constructs. A validated non-linear fiber-reinforced poro-elastic swelling cartilage model that can accommodate for effects of collagen reinforcement and swelling by proteoglycans was used. At the tissue scale, ECM was gradually varied from predominantly localized in the periphery of the TE construct toward an ECM-rich inner core. The effect of these inhomogeneities in relation to the total amount of ECM was also evaluated. At the cell scale, ECM was gradually varied from localized in the pericellular area, toward equally distributed throughout the interterritorial area. Results from the tissue-scale model indicated that localization of ECM in either the construct periphery or in the inner core may reduce construct stiffness compared with that of constructs with homogeneous ECM. Such effects are more significant at high ECM amounts. At the cell scale, localization of ECM around the cells significantly reduced the overall stiffness, even at low ECM amounts. The compressive stiffness gradually increased when ECM distribution became more homogeneous and the osmotic swelling pressure in the interterritorial area increased. We conclude that for the same amount of ECM content in TE cartilage constructs, superior mechanical properties can be achieved with more homogeneous ECM distribution at both tissue and cell scale. Inhomogeneities at the cell scale are more important than those at the tissue scale.  相似文献   

10.
Our group has shown that numerous factors can influence how tissue engineered tendon constructs respond to in vitro mechanical stimulation. Although one study showed that stimulating mesenchymal stem cell (MSC)-collagen sponge constructs significantly increased construct linear stiffness and repair biomechanics, a second study showed no such effect when a collagen gel replaced the sponge. While these results suggest that scaffold material impacts the response of MSCs to mechanical stimulation, a well-designed intra-animal study was needed to directly compare the effects of type-I collagen gel versus type-I collagen sponge in regulating MSC response to a mechanical stimulus. Eight constructs from each cell line (n=8 cell lines) were created in specially designed silicone dishes. Four constructs were created by seeding MSCs on a type-I bovine collagen sponge, and the other four were formed by seeding MSCs in a purified bovine collagen gel. In each dish, two cell-sponge and two cell-gel constructs from each line were then mechanically stimulated once every 5 min to a peak strain of 2.4%, for 8 h/day for 2 weeks. The other dish remained in an incubator without stimulation for 2 weeks. After 14 days, all constructs were failed to determine mechanical properties. Mechanical stimulation significantly improved the linear stiffness (0.048+/-0.009 versus 0.015+/-0.004; mean+/-SEM (standard error of the mean ) N/mm) and linear modulus (0.016+/-0.004 versus 0.005+/-0.001; mean+/-SEM MPa) of cell-sponge constructs. However, the same stimulus produced no such improvement in cell-gel construct properties. These results confirm that collagen sponge rather than collagen gel facilitates how cells respond to a mechanical stimulus and may be the scaffold of choice in mechanical stimulation studies to produce functional tissue engineered structures.  相似文献   

11.
It is generally accepted that dynamic culture conditions are required for vascular tissue engineering. We compared the effects of two dynamic culture systems, a perfusion and a rotating bioreactor, using tubular constructs based on hyaluronic acid seeded with porcine aortic smooth muscle cells (SMC), that we recently showed to be adequate for the generation of vascular tissue. In perfused constructs mechanical stimulation importantly affected cell morphology, increased the incidence of cell proliferation and reduced apoptosis. However, extracellular matrix deposition, cytoskeletal organization and mechanical properties were poor. In rotated constructs cell proliferation was also higher and apoptosis lower than in static controls. Rotated constructs showed the highest ultimate stress and the lowest elastic modulus. Our data indicate that the rotating bioreactor is more efficient than the perfusion bioreactor and we then suggest that this method can be considered a valid alternative to complex bioreactor systems described in the literature.  相似文献   

12.
Contractile skeletal muscle tissue-engineered on an acellular scaffold   总被引:4,自引:0,他引:4  
Borschel GH  Dennis RG  Kuzon WM 《Plastic and reconstructive surgery》2004,113(2):595-602; discussion 603-4
For the reconstructive surgeon, tissue-engineered skeletal muscle may offer reduced donor-site morbidity and an unlimited supply of tissue. Using an acellularized mouse extensor digitorum longus muscle as a scaffold, the authors produced engineered skeletal muscle capable of generating longitudinal force. Eight extensor digitorum longus muscles from adult mice were made acellular using a protocol developed in the authors' laboratory. The acellular muscles were then placed in a bath of 20% fetal bovine serum in Dulbecco's modified Eagle's medium and 100 U/ml penicillin for 1 week at room temperature. C2C12 myoblasts were injected into the acellular muscle matrix using a 26-gauge needle and a 100-microl syringe. The resulting constructs were placed in growth medium for 1 week at 37 degrees C under 5% carbon dioxide, with media changes every 48 hours. The constructs were then placed in differentiation medium for 1 week, with media changes every 48 hours. Isometric contractile force testing of the constructs demonstrated production of longitudinal contractile force on electrical stimulation. A length-tension, or Starling, relationship was observed. Light and electron microscopy studies demonstrated recapitulation of some of the normal histologic features of developing skeletal muscle.  相似文献   

13.
In this paper, we describe the effects of the combination of topographical, mechanical, chemical and intracellular electrical stimuli on a co-culture of fibroblasts and skeletal muscle cells. The co-culture was anisotropically grown onto an engineered micro-grooved (10 µm-wide grooves) polyacrylamide substrate, showing a precisely tuned Young’s modulus (∼ 14 kPa) and a small thickness (∼ 12 µm). We enhanced the co-culture properties through intracellular stimulation produced by piezoelectric nanostructures (i.e., boron nitride nanotubes) activated by ultrasounds, thus exploiting the ability of boron nitride nanotubes to convert outer mechanical waves (such as ultrasounds) in intracellular electrical stimuli, by exploiting the direct piezoelectric effect. We demonstrated that nanotubes were internalized by muscle cells and localized in both early and late endosomes, while they were not internalized by the underneath fibroblast layer. Muscle cell differentiation benefited from the synergic combination of topographical, mechanical, chemical and nanoparticle-based stimuli, showing good myotube development and alignment towards a preferential direction, as well as high expression of genes encoding key proteins for muscle contraction (i.e., actin and myosin). We also clarified the possible role of fibroblasts in this process, highlighting their response to the above mentioned physical stimuli in terms of gene expression and cytokine production. Finally, calcium imaging-based experiments demonstrated a higher functionality of the stimulated co-cultures.  相似文献   

14.
Articular cartilage suffers from a limited repair capacity when damaged by mechanical insult or degraded by disease, such as osteoarthritis. To remedy this deficiency, several medical interventions have been developed. One such method is to resurface the damaged area with tissue-engineered cartilage; however, the engineered tissue typically lacks the biochemical properties and durability of native cartilage, questioning its long-term survivability. This limits the application of cartilage tissue engineering to the repair of small focal defects, relying on the surrounding tissue to protect the implanted material. To improve the properties of the developed tissue, mechanical stimulation is a popular method utilized to enhance the synthesis of cartilaginous extracellular matrix as well as the resultant mechanical properties of the engineered tissue. Mechanical stimulation applies forces to the tissue constructs analogous to those experienced in vivo. This is based on the premise that the mechanical environment, in part, regulates the development and maintenance of native tissue1,2. The most commonly applied form of mechanical stimulation in cartilage tissue engineering is dynamic compression at physiologic strains of approximately 5-20% at a frequency of 1 Hz1,3. Several studies have investigated the effects of dynamic compression and have shown it to have a positive effect on chondrocyte metabolism and biosynthesis, ultimately affecting the functional properties of the developed tissue4-8. In this paper, we illustrate the method to mechanically stimulate chondrocyte-agarose hydrogel constructs under dynamic compression and analyze changes in biosynthesis through biochemical and radioisotope assays. This method can also be readily modified to assess any potentially induced changes in cellular response as a result of mechanical stimuli.  相似文献   

15.
Review: Hydrogels for cell immobilization   总被引:6,自引:0,他引:6  
Hydrogels are being investigated for mammalian cell immobilization. Their material properties can be engineered for biocompatibility, selective permeability, mechanical and chemical stability, and other requirements as specified by the application including uniform cell distribution and a given membrane thickness or mechanical strength. These aqueous gels are attractive for analytical and tissue engineering applications and can be used with immobilization in therapies for various diseases as well as to generate bioartificial organs. Recent advances have broadened the use of hydrogel cell immobilization in biomedical fields. To provide an overview of available technology, this review surveys the current developments in immobilization of mammalian cells in hydrogels. Discussions cover hydrogel requirements for use in adhesion, matrix entrapment, and microencapsulation, the respective processing methods, as well as current applications. (c) 1996 John Wiley & Sons, Inc.  相似文献   

16.
Applied tissue engineering in regenerative medicine warrants our enhanced understanding of the biomaterials and its function. The aim of this study was to evaluate the proliferation and differentiation potential of human adipose-derived stem cells (hADSCs) grown on chitosan hydrogel. The stability of this hydrogel is pH-dependent and its swelling property is pivotal in providing a favorable matrix for cell growth. The study utilized an economical method of cross linking the chitosan with 0.5% glutaraldehyde. Following the isolation of hADSCs from omentum tissue, these cells were cultured and characterized on chitosan hydrogel. Subsequent assays that were performed included JC-1 staining for the mitochondrial integrity as a surrogate marker for viability, cell proliferation and growth kinetics by MTT assay, lineage specific differentiation under two-dimensional culture conditions. Confocal imaging, scanning electron microscopy (SEM), and flow cytometry were used to evaluate these assays. The study revealed that chitosan hydrogel promotes cell proliferation coupled with > 90% cell viability. Cytotoxicity assays demonstrated safety profile. Furthermore, glutaraldehyde cross linked chitosan showed < 5% cytotoxicity, thus serving as a scaffold and facilitating the expansion and differentiation of hADSCs across endoderm, ectoderm and mesoderm lineages. Additional functionalities can be added to this hydrogel, particularly those that regulate stem cell fate.  相似文献   

17.
Complete reconstruction of damaged periodontal pockets, particularly regeneration of periodontal ligament (PDL) has been a significant challenge in dentistry. Tissue engineering approach utilizing PDL stem cells and scaffolding matrices offers great opportunity to this, and applying physical and mechanical cues mimicking native tissue conditions are of special importance. Here we approach to regenerate periodontal tissues by engineering PDL cells supported on a nanofibrous scaffold under a mechanical-stressed condition. PDL stem cells isolated from rats were seeded on an electrospun polycaprolactone/gelatin directionally-oriented nanofiber membrane and dynamic mechanical stress was applied to the cell/nanofiber construct, providing nanotopological and mechanical combined cues. Cells recognized the nanofiber orientation, aligning in parallel, and the mechanical stress increased the cell alignment. Importantly, the cells cultured on the oriented nanofiber combined with the mechanical stress produced significantly stimulated PDL specific markers, including periostin and tenascin with simultaneous down-regulation of osteogenesis, demonstrating the roles of topological and mechanical cues in altering phenotypic change in PDL cells. Tissue compatibility of the tissue-engineered constructs was confirmed in rat subcutaneous sites. Furthermore, in vivo regeneration of PDL and alveolar bone tissues was examined under the rat premaxillary periodontal defect models. The cell/nanofiber constructs engineered under mechanical stress showed sound integration into tissue defects and the regenerated bone volume and area were significantly improved. This study provides an effective tissue engineering approach for periodontal regeneration—culturing PDL stem cells with combinatory cues of oriented nanotopology and dynamic mechanical stretch.  相似文献   

18.
Embryonic stem cell (ESC) derivatives are a promising cell source for cardiac cell therapy. Mechanistic studies upon cell injection in conventional animal models are limited by inefficient delivery and poor cell survival. As an alternative, we have used an engineered heart tissue (EHT) based on neonatal rat cardiomyocytes (CMs) cultivated with electrical field stimulation as an in vitro model to study cell injection. We injected (0.001, 0.01, and 0.1 million) and tracked (by qPCR and histology) undifferentiated yellow‐fluorescent protein transgenic mouse ESCs and Flk1 + /PDGFRα+ cardiac progenitor (CPs) cells, to investigate the effect of the cardiac environment on cell differentiation, as well as to test whether our in vitro model system could recapitulate the formation of teratoma‐like structures commonly observed upon in vivo ESC injection. By 8 days post‐injection, ESCs were spatially segregated from the cardiac cell population; however, ESC injection increased survival of CMs. The presence of ESCs blocked electrical conduction through the tissue, resulting in a 46% increase in the excitation threshold. Expression of mouse cardiac troponin I, was markedly increased in CP injected constructs compared to ESC injected constructs at all time points and cell doses tested. As early as 2 weeks, epithelial and ganglion‐like structures were observed in ESC injected constructs. By 4 weeks of ESC injection, teratoma‐like structures containing neural, epithelial, and connective tissue were observed in the constructs. Non‐cardiac structures were observed in the CP injected constructs only after extended culture (4 weeks) and only at high cell doses, suggesting that these cells require further enrichment or differentiation prior to transplantation. Our data indicate that the cardiac environment of host tissue and electrical field stimulation did not preferentially guide the differentiation of ESCs towards the cardiac lineage. In the same environment, injection of CP resulted in a more robust cardiac differentiation than injection of ESC. Our data demonstrate that the model‐system developed herein can be used to study the functional effects of candidate stem cells on the host myocardium, as well as to measure the residual activity of undifferentiated cells present in the mixture. Biotechnol. Bioeng. 2011; 108:704–719. © 2010 Wiley Periodicals, Inc.  相似文献   

19.
In the creation of engineered tissue constructs, the successful transport of nutrients and oxygen to the contained cells is a significant challenge. In highly porous scaffolds subject to cyclic strain, the mechanical deformations can induce substantial fluid pressure gradients, which affect the transport of solutes. In this article, we describe a poroelastic model to predict the solid and fluid mechanics of a highly porous hydrogel subject to cyclic strain. The model was validated by matching the predicted penetration of a bead into the hydrogel from the model with experimental observations and provides insight into nutrient transport. Additionally, the model provides estimates of the wall-shear stresses experienced by the cells embedded within the scaffold. These results provide insight into the mechanics of and convective nutrient transport within a cyclically strained hydrogel, which could lead to the improved design of engineered tissues.  相似文献   

20.
In the creation of engineered tissue constructs, the successful transport of nutrients and oxygen to the contained cells is a significant challenge. In highly porous scaffolds subject to cyclic strain, the mechanical deformations can induce substantial fluid pressure gradients, which affect the transport of solutes. In this article, we describe a poroelastic model to predict the solid and fluid mechanics of a highly porous hydrogel subject to cyclic strain. The model was validated by matching the predicted penetration of a bead into the hydrogel from the model with experimental observations and provides insight into nutrient transport. Additionally, the model provides estimates of the wall-shear stresses experienced by the cells embedded within the scaffold. These results provide insight into the mechanics of and convective nutrient transport within a cyclically strained hydrogel, which could lead to the improved design of engineered tissues.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号