1.

Purpose

To identify corneal epithelial- and stromal-thickness distribution patterns in keratoconus using spectral-domain optical coherence tomography (SD-OCT).

Patients and Methods

We analyzed SD-OCT findings in 20 confirmed cases of keratoconus (group 1) and in 20 healthy subjects with corneal astigmatism ≥2 D (group 2). Epithelial and stromal thicknesses were measured at 11 strategic locations along the steepest and flattest meridians, previously located by corneal topography. Vertical mirrored symmetry superimposition was used in the statistical analysis.

Results

The mean maximum keratometry measurements in groups 1 and 2 were 47.9±2.9 D (range, 41.8–52.8) and 45.6±1.1 D (range, 42.3–47.5), respectively, with mean corneal cylinders of 3.3±2.2 D (range, 0.5–9.5) and 3.6±1.2 D (range, 2.0–6.4), respectively. The mean epithelial thickness along the steepest meridian in group 1 was the lowest (37.4±4.4 µm) at 1.2 mm inferotemporally and the highest (59.3±4.4 µm) at 1.4 mm supranasally from the corneal vertex. There was only a small deviation in thickness along the steepest meridian in group 2, as well as along the flattest meridians in both groups. The stromal thickness distribution in the two groups was similar to the epithelial, while the stromal thickness was generally lower in group 1 than in group 2.

Conclusions

SD-OCT provides details about the distribution of corneal epithelial and stromal thicknesses. The epithelium and stroma in keratoconic eyes were thinner inferotemporally and thicker supranasally compared with control eyes. The distribution pattern was more distinct in epithelium than in stroma. This finding may help improve the early diagnosis of keratoconus.

Trial Registration

ClinicalTrials.gov NCT02023619  相似文献   

2.

Background

This study determines ‘correlation constants’ between the gold standard histological measurement of retinal thickness and the newer spectral-domain optical coherence tomography (SD-OCT) technology in adult C57BL/6 mice.

Methods

Forty-eight eyes from adult mice underwent SD-OCT imaging and then were histologically prepared for frozen sectioning with H&E staining. Retinal thickness was measured via 10x light microscopy. SD-OCT images and histological sections were standardized to three anatomical sites relative to the optic nerve head (ONH) location. The ratios between SD-OCT to histological thickness for total retinal thickness (TRT) and six sublayers were defined as ‘correlation constants’.

Results

Mean (± SE) TRT for SD-OCT and histological sections was 210.95 µm (±1.09) and 219.58 µm (±2.67), respectively. The mean ‘correlation constant’ for TRT between the SD-OCT and histological sections was 0.96. The retinal thickness for all sublayers measured by SD-OCT vs. histology were also similar, the ‘correlation constant’ values ranged from 0.70 to 1.17. All SD-OCT and histological measurements demonstrated highly significant (p<0.01) strong positive correlations.

Conclusion

This study establishes conversion factors for the translation of ex vivo data into in vivo information; thus enhancing the applicability of SD-OCT in translational research.  相似文献   

3.

Objective

To report normative data for retinal thickness in wild-type C57BL/6 mouse utilizing a miniature SD-OCT system.

Methods

Thirty adult mice (range: 3–5 months) were anesthetized and secured into the Bioptigen Spectral Domain Ophthalmic Imaging System. Right eye SD-OCT images were standardized by centralizing the optic nerve head (ONH) prior to image acquisition. Global and quadrant total retinal thickness (TRT) values were measured from retinal nerve fiber layer to retinal pigment epithelial layer. Posterior segment analyses also included the outer retinal layer (ORL) and inner retinal layer (IRL). Further sublayer analyses of four layers from the ORL and three layers comprising the IRL were also performed.

Results

The overall mean±SD global TRT in a C57BL/6 mouse model was 204.41±5.19 µm. Quadrant mean TRT values were 204.85±5.81 µm inferiorly, 204.97±6.71 µm nasally, 205.08±5.44 µm temporally, and 202.74±4.85 µm superiorly. Mean±SD thickness for ORL, and IRL were 126.37±10.01 µm, and 107.03±10.98 µm respectively. The mean±SD estimates for the four layers of the ORL were 18.23±2.73 µm, 26.04±4.21 µm, 63.8±6.23 µm, and 19.22±4.34 µm. Mean±SD values for the three IRL sublayers were 27.82±4.04 µm, 59.62±6.66 µm and 19.12±3.71 µm.

Conclusion

This study established normative values for the total retinal thickness and sublayer thickness for the wild-type C57BL/6 mice. Moreover, it provides a standard of retinal morphology, in a commonly used animal model, for evaluating therapeutic interventions and retinal disease pathophysiology.  相似文献   

4.

Purpose

To further elucidate retinal findings and retinal vessel changes in Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) patients by means of high resolution retinal imaging.

Methods

28 eyes of fourteen CADASIL patients and an equal number of control subjects underwent confocal scanning laser ophthalmoscopy (cSLO), spectral-domain optical coherence tomography (SD-OCT), retinal nerve fibre layer (RNFL) measurements, fluorescein and indocyanine angiography. Three vessel measurement techniques were applied: RNFL thickness, a semiautomatic software tool based on cSLO images and manual vessel outlining based on SD-OCT.

Results

Mean age of patients was 56.2±11.6 years. Arteriovenous nicking was present in 22 (78.6%) eyes and venous dilation in 24 (85.7%) eyes. Retinal volume and choroidal volume were 8.77±0.46 mm3 and 8.83±2.24 mm3. RNFL measurements showed a global increase of 105.2 µm (Control group: 98.4 µm; p = 0.015). Based on semi-automatic cSLO measurements, maximum diameters of arteries and veins were 102.5 µm (106.0 µm; p = 0.21) and 128.6 µm (124.4 µm; p = 0.27) respectively. Manual SD-OCT measurements revealed significantly increased mean arterial 138.7 µm (125.4 µm; p<0.001) and venous 160.0 µm (146.9; p = 0.003) outer diameters as well as mean arterial 27.4 µm (19.2 µm; p<0.001) and venous 18.3 µm (15.7 µm; p<0.001) wall thicknesses in CADASIL patients.

Conclusions

The findings reflect current knowledge on pathophysiologic changes in vessel morphology in CADASIL patients. SD-OCT may serve as a complementary tool to diagnose and follow-up patients suffering from cerebral small-vessel diseases.  相似文献   

5.

Purpose

To determine the axial length requiring adjustment of measured circumpapillary retinal nerve fiber layer (cpRNFL) thickness to account for ocular magnification during spectral-domain optical coherence tomography (SD-OCT).

Methods

In this prospective study, 148 eyes of 148 healthy student volunteers were imaged by two examiners using three-dimensional SD-OCT. In 54 randomly selected eyes, total cpRNFL thickness was measured with and without adjustment for ocular magnification to establish intra-examiner and inter-examiner measurement error. The 148 eyes were then divided into three groups according to the error values: control group (difference in the corrected and uncorrected total cpRNFL thickness was within the measurement error range), thinner group (the corrected total cpRNFL thickness was less than the uncorrected one), and thicker group (the corrected total cpRNFL thickness was more than the uncorrected one). The cutoff values of axial length between the control and the other groups were calculated by receiver operating characteristic analysis.

Results

Measurement error ranged from 4.2 to 5.3 µm; the threshold value was defined as 5.3 µm. The cutoff values of axial length between the thinner and the control groups and between the control and the thicker groups were 23.60 (area under the curve [AUC] = 0.959) and 25.55 (AUC = 0.944) mm, respectively.

Conclusions

Axial lengths shorter than 23.60 mm and longer than 25.55 mm require adjustment of measured cpRNFL thickness to account for ocular magnification during SD-OCT.

Clinical Trial Registration

UMIN Clinical Trials Registry (http://www.umin.ac.jp/) under unique trial number UMIN000013248 (date of registration: 02/24/2014)  相似文献   

6.

Main objective

To evaluate the distribution of central corneal thickness (CCT) in a large German cohort and to analyse its relationship with intraocular pressure and further ocular factors.

Design

Population-based, prospective, cohort study.

Methods

The Gutenberg Health Study (GHS) cohort included 4,698 eligible enrollees of 5,000 subjects (age range 35–74 years) who participated in the survey from 2007 to 2008. All participants underwent an ophthalmological examination including slitlamp biomicroscopy, intraocular pressure measurement, central corneal thickness measurement, fundus examination, and were given a questionnaire regarding glaucoma history. Furthermore, all subjects underwent fundus photography and visual field testing using frequency doubling perimetry.

Results

Mean CCT was 557.3±34.3 µm (male) and 551.6±35.2 µm in female subjects (Mean CCT from right and left eyes). Younger male participants (35–44 years) presented slightly thicker CCT than those older. We noted a significant CCT difference of 4 µm between right and left eyes, but a high correlation between eyes (Wilcoxon test for related samples: p<0.0001). Univariable linear regression stratified by gender showed that IOP was correlated with CCT (p<0.0001). A 10 µm increase in CCT led to an increase in IOP between 0.35–0.38 mm Hg, depending on the eye and gender. Multivariable linear regression analysis revealed correlations between gender, spherical equivalent (right eyes), and CCT (p<.0001 and p = 0.03, respectively).

Conclusions

We observed positive correlations between CCT and IOP and gender. CCT was not correlated with age, contact lens wear, positive family history for glaucoma, lens status, or iris colour.  相似文献   

7.

Purpose

To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software.

Methods

High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy volunteers. Two scans were obtained in a single visit for each participant. Using new Spectralis segmentation software, two investigators independently obtained thickness of each of eight individual retinal layers at 0°, 2° and 5° eccentricities nasal and temporal to foveal centre, as well as foveal width measurements. Bland-Altman Coefficient of Repeatability (CoR) was calculated for inter-investigator and inter-scan agreement of all retinal measurements. Spearman''s ρ indicated correlation of manually located central retinal thickness (RT0) with automated minimum foveal thickness (MFT) measurements. In addition, we investigated nasal-temporal symmetry of individual retinal layer thickness within the foveal pit.

Results

Inter-scan CoR values ranged from 3.1μm for axial retinal nerve fibre layer thickness to 15.0μm for the ganglion cell layer at 5° eccentricity. Mean foveal width was 2550μm ± 322μm with a CoR of 13μm for inter-investigator and 40μm for inter-scan agreement. Correlation of RT0 and MFT was very good (ρ = 0.97, P < 0.0005). There were no significant differences in thickness of any individual retinal layers at 2° nasal compared to temporal to fovea (P > 0.05); however this symmetry could not be found at 5° eccentricity.

Conclusions

We demonstrate excellent repeatability and reproducibility of each of eight individual retinal layer thickness measurements within the fovea as well as foveal width using Spectralis SD-OCT segmentation software in a young, healthy cohort. Thickness of all individual retinal layers were symmetrical at 2°, but not at 5° eccentricity away from the fovea.  相似文献   

8.

Purpose

To evaluate choroidal thickness (CT) in healthy and glaucomatous eyes using Swept Source Optical Coherence Tomography (SS-OCT).

Methods

A cross-sectional observational study of 216 eyes of 140 subjects with glaucoma and 106 eyes of 67 healthy subjects enrolled in the Diagnostic Innovations in Glaucoma Study. CT was assessed from wide-field (12×9 mm) SS-OCT scans. The association between CT and potential confounding variables including age, gender, axial length, intraocular pressure, central corneal thickness and ocular perfusion pressure was examined using univariable and multivariable regression analyses.

Results

Overall CT was thinner in glaucomatous eyes with a mean (± standard deviation) of 157.7±48.5 µm in glaucoma compared to 179.9±36.1 µm in healthy eyes (P<0.001). The choroid was thinner in both the peripapillary and macular regions in glaucoma compared to controls. Mean peripapillary CT was 154.1±44.1 µm and 134.0±56.9 µm (P<0.001) and macular CT 199.3±46.1 µm and 176.2±57.5 µm (P<0.001) for healthy and glaucomatous eyes respectively. However, older age (P<0.001) and longer axial length (P<0.001) were also associated with thinner choroid and when differences in age and axial length between glaucomatous and healthy subjects were accounted for, glaucoma was not significantly associated with CT. There was also no association between glaucoma severity and CT.

Conclusions

Glaucoma was not associated with CT measured using SS-OCT; however, older age and longer axial length were associated with thinner choroid so should be considered when interpreting CT measurements.  相似文献   

9.

Background

Combination of riboflavin/UVA cross-linking (CXL) and excimer laser ablation is a promising therapy for treating corneal ectasia. The cornea is strengthened by cross-linking, while the irregular astigmatism is reduced by laser ablation. This study aims to compare the efficacy of excimer laser ablation on porcine corneas with and without cross-linking.

Methods and Findings

The porcine cornea was de-epithelialized and treated with 0.1% riboflavin solution for 30 minutes. A half of the cornea was exposed to UVA-radiation for another 30 minutes while the controlled half of the cornea was protected from the UVA using a metal shield. Photo therapeutic keratectomy (PTK) was then performed on the central cornea. Corneal thickness of 5 paired locations on the horizontal line, ±0.5, ±1.0, ±1.5, ±2.0, and ±2.5 mm from the central spot, were measured using optical coherence tomography prior to and after PTK. The ablation depth was then determined by the corneal thickness. There was a 9% difference (P<0.001) in the overall ablation depth between the CXL-half corneas (158±22 µm) and the control-half corneas (174±26 µm). The ablation depths of all 5 correspondent locations on the CXL-half were significantly smaller (P<0.001).

Conclusion

The efficacy of the laser ablation seems to be lower in cross-linked cornea. Current ablation algorithms may need to be modified for cross-linked corneas.  相似文献   

10.

Aim

To investigate colonic mucus thickness in vivo in health and during experimental inflammatory bowel disease.

Methods

Colitis was induced with 5% DSS in drinking water for 8 days prior to experiment, when the descending colonic mucosa of anesthetized rats was studied using intravital microscopy. Mucus thickness was measured with micropipettes attached to a micromanipulator. To assess the contributions of NOS and prostaglandins in the regulation of colonic mucus thickness, the non-selective NOS-inhibitor L-NNA (10 mg/kg bolus followed by 3 mg/kg/h), the selective iNOS-inhibitor L-NIL (10 mg/kg bolus followed by 3 mg/kg/h) and the non-selective COX-inhibitor diclofenac (5 mg/kg) were administered intravenously prior to experiment. To further investigate the role of iNOS in the regulation of colonic mucus thickness, iNOS −/− mice were used.

Results

Colitic rats had a thicker firmly adherent mucus layer following 8 days of DSS treatment than untreated rats (88±2 µm vs 76±1 µm). During induction of colitis, the thickness of the colonic mucus layer initially decreased but was from day 3 significantly thicker than in untreated rats. Diclofenac reduced the mucus thickness similarly in colitic and untreated rats (−16±5 µm vs −14±2 µm). While L-NNA had no effect on colonic mucus thickness in DSS or untreated controls (+3±2 µm vs +3±1 µm), L-NIL reduced the mucus thickness significantly more in colitic rats than in controls (−33±4 µm vs −10±3 µm). The importance of iNOS in regulating the colonic mucus thickness was confirmed in iNOS−/− mice, which had thinner colonic mucus than wild-type mice (35±3 µm vs 50±2 µm, respectively). Furthermore, immunohistochemistry revealed increased levels of iNOS in the colonic surface epithelium following DSS treatment.

Conclusion

Both prostaglandins and nitric oxide regulate basal colonic mucus thickness. During onset of colitis, the thickness of the mucus layer is initially reduced followed by an iNOS mediated increase.  相似文献   

11.

Purpose

Thickness changes of corneal sub-layers after phacoemulsification were investigated by spectral domain ultra-high resolution optical coherence tomography (UHR-OCT).

Methods

The corneas (n = 26) of 26 age-related cataract surgery patients were studied. UHR-OCT was used to evaluate the thickness of Descemet’s Endothelium Complex (DEC), stroma, Bowman’s layer, epithelium, and full cornea at the center (CCT) before, one day after, and one week after surgery. Non-contact specular microscopy measured CCT, endothelial cell density, and morphology.

Results

The DEC, stroma, Bowman’s layer, and epithelium were visualized by UHR-OCT. Before surgery, the DEC in all cases appeared as a translucent space between two smooth opaque lines. One day after surgery, the posterior corneal surfaces in half of the eyes were wavy and irregular. Compared to the baseline, one day after surgery the thickness increases of the DEC, stroma, and CCT were 4.3 ± 2.6 µm, 25.5 ± 24.9 µm, and 32.1 ± 26.6 µm, respectively (P < 0.001). The morphology of the DEC and the CCT recovered to baseline one week after surgery (P > 0.05), but endothelial cell density was 8.7% less than at baseline. There were no significant changes in Bowman’s layer and epithelium after the operation. The pre-operative DEC thickness was positively correlated with the decreased endothelial cell density at 1 day after surgery (r = 0.55, P = 0.003).

Conclusions

The DEC showed edematous thickening and different degrees of morphological changes after phacoemulsification. The DEC deformation and corneal edema recovered by one week after surgery, which indicated recovery of endothelial function. UHR-OCT is a useful tool to evaluate function of the DEC after phacoemulsification. Pre-operative DEC thickness may indicate the integrity of the endothelium and could be used for predicting endothelial cell loss after phacoemulsification.  相似文献   

12.

Purpose

To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT).

Methods

We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses.

Results

Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively.

Conclusions

The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement.  相似文献   

13.

Purpose

To investigate the morphology of corneal caps in femtosecond laser small incision lenticule extraction (SMILE) and its relation to the refractive outcomes.

Methods

A prospective study of fifty-four corneal caps created with VisuMax femtosecond laser were examined using an Fourier-domain optical coherence tomography at 1 day, 1 week, 1 month and 6 months after SMILE. The cap thickness at nine points on each of the four meridians (0°, 45°, 90°, 135°) and the diameter were measured. Cap morphology, changes over time and its correlation with refractive outcomes were assessed.

Results

The mean achieved central cap thickness were (108.74±5.06) µm at 6 months and (107.32±4.81 ) µm at 1 month postoperatively, significantly thinner than that at 1 day (110.81±7.95) µm and 1 week (109.58±7.48 ) µm (P<0.05). The mean diameter on 0° meridian was (7.61±0.07) mm, significantly larger than that on 90° meridian (7.57±0.06) mm (P = 0.001). Cap morphology showed good regularity, except that the differences of points in two pairs were significant at 1 day postoperatively. The uniformity was consistent over time and the central cap thickness was thinner than those in the paracentral and peripheral areas. The refractive outcomes stabilized within 1 month. Uncorrected distance visual acuity (UDVA) was correlated to the central cap thickness at 1 day and 1 week (both rs = 0.33, p<0.05). The uniformity index was correlated with UDVA (rs = 0.34, p<0.05) and corrected distance visual acuity (rs = 0.32, p<0.05) at 1 week postoperatively.

Conclusions

Corneal caps of SMILE are predictable with good reproducibility, regularity and uniformity. Cap morphology might have a mild effect on refractive outcomes in the early stage. Further study should focus on the impact on the visual quality.  相似文献   

14.

Purpose

To develop EdgeSelect, a semi-automatic method for the segmentation of retinal layers in spectral domain optical coherence tomography images, and to compare the segmentation results with a manual method.

Methods

SD-OCT (Heidelberg Spectralis) scans of 28 eyes (24 patients with diabetic macular edema and 4 normal subjects) were imported into a customized MATLAB application, and were manually segmented by three graders at the layers corresponding to the inner limiting membrane (ILM), the inner segment/ellipsoid interface (ISe), the retinal/retinal pigment epithelium interface (RPE), and the Bruch''s membrane (BM). The scans were then segmented independently by the same graders using EdgeSelect, a semi-automated method allowing the graders to guide/correct the layer segmentation interactively. The inter-grader reproducibility and agreement in locating the layer positions between the manual and EdgeSelect methods were assessed and compared using the Wilcoxon signed rank test.

Results

The inter-grader reproducibility using the EdgeSelect method for retinal layers varied from 0.15 to 1.21 µm, smaller than those using the manual method (3.36–6.43 µm). The Wilcoxon test indicated the EdgeSelect method had significantly better reproducibility than the manual method. The agreement between the manual and EdgeSelect methods in locating retinal layers ranged from 0.08 to 1.32 µm. There were small differences between the two methods in locating the ILM (p = 0.012) and BM layers (p<0.001), but these were statistically indistinguishable in locating the ISe (p = 0.896) and RPE layers (p = 0.771).

Conclusions

The EdgeSelect method resulted in better reproducibility and good agreement with a manual method in a set of eyes of normal subjects and with retinal disease, suggesting that this approach is feasible for OCT image analysis in clinical trials.  相似文献   

15.

Purpose

To investigate whether corneal thickness parameters measured by optical coherence tomography (OCT), such as central corneal thickness (CCT), central corneal stromal thickness (CCST), and central corneal epithelial thickness (CCET), influence the intraocular pressure (IOP) difference measured by Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT).

Methods

In total, 50 eyes from 50 subjects without glaucomatous defects were included in this retrospective, cross-sectional study. We measured IOP using GAT and NCT and calculated the difference between the two methods. CCT was measured by a Cirrus HD-OCT device using anterior segment imaging. The basement membrane of the epithelium, which was seen as a high-reflection line in the OCT image, was taken as a reference line to measure CCST and CCET.

Results

The mean IOP measured by GAT and NCT was 16.7 ± 3.0 and 18.1 ± 3.8 mmHg, respectively. The mean IOP difference was 1.5 ± 1.7 mmHg, and the IOP measured by NCT was 8.4% ± 11.3% higher than that measured by GAT. The CCET and CCST were 57.9 ± 5.6 and 501.7 ± 33.8 μm, respectively. CCT showed a positive correlation with both GAT IOP (r = 0.648, P < 0.001) and NCT IOP (r = 0.676, P < 0.001). Although CCST showed a significant correlation with GAT IOP and NCT IOP, CCET did not. The difference between GAT IOP and NCT IOP increased with CCT (r = 0.333, P = 0.018), and CCET was positively correlated with the IOP difference between GAT and NCT (r = 0.435, P = 0.002).

Conclusions

IOP increased with greater CCT, and CCST seemed to have a more important role than CCET. CCET also increased with greater CCT, and this may be a possible explanation for the increasing difference in IOP between GAT and NCT with increasing CCT.  相似文献   

16.

Purpose

To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes.

Methods

Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18–42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated.

Results

The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young''s modulus of the anterior cornea ranged between 2.28±0.87 MPa and 3.30±0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young''s modulus of the posterior cornea was on average 0.21±0.09 MPa and 0.17±0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function.

Conclusion

Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes.  相似文献   

17.

Purpose

To measure retinal nerve fiber layer (RNFL) thickness in a population-based setting.

Methods

In the population-based Beijing Eye Study 2011 with 3468 individuals, RNFL thickness was measured in a subgroup of 1654 (47.7%) study participants by spectral domain optical coherence tomography (iVue SD-OCT).

Results

Mean RNFL thickness was significantly (P<0.001) higher in the inferior sector (131.4±20.6 µm) than the superior sector (126.1±19.1 µm), where it was higher than in the temporal sector (79.8±12.2 µm;P<0.001), where it was higher than in the nasal sector (75.1±12.6 µm;P<0.001). In multivariate analysis, mean global RNFL thickness (103.2±12.6 µm) increased significantly with younger age (standardized correlation coefficient beta:−0.30;P<0.001), larger neuroretinal rim area (beta:0.26;P<0.001), shorter axial length (beta:−0.21;P<0.001), thicker subfoveal choroidal thickness (beta:0.15;P<0.001), larger optic disc area (beta:0.10;P<0.001), less refractive lens power (beta:0.10;P<0.001), flatter anterior cornea (beta:0.07;P = 0.01) and female gender (beta:0.05;P = 0.03). In this population with an age of 50+ years, the age-related decline in RNFL thickness was 0.5 µm per year of life or 0.36% of an original RNFL thickness of 137 µm at baseline of the study at 50 years of age. Mean global RNFL thickness decreased by 2.4 µm for each mm enlargement of axial length.

Conclusions

The RNFL profile shows a double hump configuration with the thickest part in the inferior sector, followed by the superior sector, temporal sector and nasal sector. Factors influencing global RNFL thickness were younger age, larger neuroretinal rim, shorter axial length, thicker subfoveal choroid, larger optic disc, less refractive lens power, flatter anterior cornea and female gender. Beyond an age of 50+ years, RNFL decreased by about 0.3% per year of life at an age of 50+ years and by 2.4 µm per mm of axial elongation. These findings may be of interest for the knowledge of the normal anatomy of the eye and may be of help to diagnose diseases affecting the RNFL.  相似文献   

18.

Purpose

To investigate the bilateral symmetry of the global corneal topography in normal corneas with a wide range of curvature, astigmatism and thickness values

Design

Cross-Sectional Study

Methods

Topography images were recorded for the anterior and posterior surfaces of 342 participants using a Pentacam. Elevation data were fitted to a general quadratic model that considered both translational and rotational displacements. Comparisons between fellow corneas of estimates of corneal shape parameters (elevation, radius in two main directions, Rx and Ry, and corresponding shape factors, Qx and Qy) and corneal position parameters (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) were statistically analyzed.

Results

The general quadratic model provided average RMS of fit errors with the topography data of 1.7±0.6 µm and 5.7±1.3 µm in anterior and posterior corneal surfaces. The comparisons showed highly significant bilateral correlations with the differences between fellow corneas in Rx, Ry, Qx and Qy of anterior and posterior surfaces remaining insignificantly different from zero. Bilateral differences in elevation measurements at randomly-selected points in both corneal central and peripheral areas indicated strong mirror symmetry between fellow corneas. The mean geometric center (x0, y0, z0) of both right and left corneas was located on the temporal side and inferior-temporal side of the apex in anterior and posterior topography map, respectively. Rotational displacement angle α along X axis had similar distributions in bilateral corneas, while rotation angle β along Y axis showed both eyes tilting towards the nasal side. Further, rotation angle γ along Z axis, which is related to corneal astigmatism, showed clear mirror symmetry.

Conclusions

Analysis of corneal topography demonstrated strong and statistically-significant mirror symmetry between bilateral corneas. This characteristic could help in detection of pathological abnormalities, disease diagnosis, measurement validation and surgery planning.  相似文献   

19.
20.

Purpose

To determine the distributions and relation of central corneal thickness (CCT) and intraocular pressure (IOP) by NT-530P in Chinese juveniles, and the effect of gender, age, height, weight and refractive errors on the CTT and IOP.

Methods

CCT and IOP of 982 eyes in 514 juveniles aged from 7 to 18 years were measured with NT-530P. Multi-linear regression and ANOVA analysis were used to analyze the relation of CCT and IOP, and the effect of gender, age, height, weight, refractive condition on CCT and IOP respectively.

Results

The mean CCT and IOP were 554.19±35.46 µm and 15.31±2.57 mmHg. There were significant correlations between the CCT and IOP values. Linear regression analysis revealed a positive correlation between CCT and IOP (r = 0.44, P<0.05). Linear regression equation: IOP = −2.35+0.032CCT, which means the IOP will increase 0.32 mm Hg for every 10-µm increase in CCT. The mean of Corrected IOP (CIOP) was 15.32±2.38 mmHg and had no relation with CCT. There was a negative correlation between refraction degree and CCT (P<0.05), but no correlation between refraction degree and IOP. Multi-linear regression model revealed that the height, weight, age and gender have no effect on the distribution of CCT and IOP respectively.

Conclusions

There is a 0.32 mmHg increase in IOP for every 10-µm increase in CCT. The height, weight, age and gender has no effect on the distribution of CCT and IOP. CCT will become thinner with myopia diopters increases in juveniles. The measurement of CCT is helpful in evaluating the actual IOP correctly.  相似文献   