首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The transparent polymer polyallyl-diglycol-carbonate (PADC), also known as CR-39, is widely used as detector for heavy charged particles at low fluence. It allows for detection of single protons and ions via formation of microscopic tracks after etching in NaOH or KOH solutions. PADC combines a high sensitivity and high specificity with inertness towards electromagnetic noise. Present fields of application include laser-ion acceleration, inertial confinement fusion, radiobiological studies with cell cultures, and dosimetry of nuclear fragments in particle therapy. These require precise knowledge of the energy-dependent response of PADC to different ion species. We present calibration data for a new type of detector material, Radosys RS39, to protons (0.2–3 MeV) and carbon ions (0.6–12 MeV). RS39 is less sensitive to protons than other types of PADC. Its response to carbon ions, however, is similar to other materials. Our data indicate that RS39 allows for measuring carbon ion energies up to 10 MeV only from the track diameters. In addition, it can be used for discrimination between protons and carbon ions in a single etching process.  相似文献   

2.
The ion microprobe SNAKE at the Munich 14 MV tandem accelerator achieves beam focussing by a superconducting quadrupole doublet and can make use of a broad range of ions and ion energies, from 20 MeV protons to 200 MeV gold ions. Because of these properties, SNAKE is particularly attractive for biological microbeam experiments. Here we describe the adaptation of SNAKE for microirradiation of cell samples. This includes enlarging of the focal distance in order to adjust the focal plane to the specimen stage of a microscope, construction of a beam exit window in a flexible nozzle and of a suitable cell containment, as well as development of procedures for on-line focussing of the beam, preparation of single ions and scanning by electrostatic deflection of the beam. When irradiating with single 100 MeV 16O ions, the adapted set-up permits an irradiation accuracy of 0.91 µm (full width at half maximum) in the x-direction and 1.60 µm in the y-direction, as demonstrated by retrospective track etching of polycarbonate foils. Accumulation of the repair protein Rad51, as detected by immunofluorescence, was used as a biological track detector after irradiation of HeLa cells with geometric patterns of counted ions. Observed patterns of fluorescence foci agreed reasonably well with irradiation patterns, indicating successful adaptation of SNAKE. In spite of single ion irradiation, we frequently observed split fluorescence foci which might be explained by small-scale chromatin movements.  相似文献   

3.
The yield of DNA double-strand breaks (dsb) and DNA complex lesions induced by protons and α-particles of various energies was simulated using a Monte Carlo track structure code (MOCA15) and a simple model of the DNA molecule. DNA breaks of different complexity were analysed. The linear energy transfer (LET) and particle-type dependence of lesions of higher complexity seems to confirm the importance of clustered damage in DNA as a relevant step leading to biological endpoints such as cell inactivation. The detailed structure of proton and α-particle tracks was analysed to identify the main characteristics possibly responsible for such a dependence. The role of the primary ion and of its secondary electrons in inducing dsb and complex lesions is described, showing that the relative contribution of secondary electron tracks alone in inducing clustered lesions is almost negligible at high LET, but tends to dominate below ≈10 keV/μm. This is consistent with the observed similar effectiveness of low-LET fast particle radiation and sparsely ionizing radiation such as x-rays. The dependence on LET and particle type is mainly due to energy deposition events of the primary ion together with short range electrons surrounding the ion track; the yield of complex lesions due to secondary electron tracks alone is substantially LET independent. The radial distributions of the energy contributing to the induction of complex lesions were analyzed and compared with the radial distributions of energy deposition of the full tracks. The results suggest that the stochastic behaviour (i.e. cluster properties) of the energy deposition pattern within a radius of a few nanometers around the ion track plays a relevant role in determining the biological radiation effectiveness. Received: 20 December 1996 / Accepted in revised form: 5 March 1997  相似文献   

4.
Summary AeratedVicia faba root meristems were irradiated with 1.9 MeV monoenergetic neutrons. This source of neutrons optimally provides one class of particles (recoil protons) with ranges able to traverse cell nuclei at moderate to high-LET. The volumes of theVicia faba nuclei were log-normally distributed with a mean of 1100 µm3. The yield of chromatid-type aberrations was linear against absorbed dose and near-constant over 5 collection periods (2–12 h), after irradiation. Energy deposition events (recoil protons) determined by microdosimetry were related to cytological changes with the finding that 19% of incident recoil protons initiate visible changes inVicia faba chromosomes. It is probable that a substantial fraction of recoil proton track length and deposited energy is in insensitive (non-DNA containing) portions of the nuclear volume.  相似文献   

5.
Plasmid pGEM 3zf(+) was irradiated by nitrogen ion beam with energies between 20 and 100 keV and the fluence kept as 1×1012 ions/cm2. The irradiated plasmid was assayed by neutral electrophoresis and quantified by densitometry. The yields of DNA with single-strand and double-strand breaks first increased then decreased with increasing ion energy. There was a maximal yield value in the range of 20–100 keV. The relationship between DNA double-strand breaks (DSB) cross-section and linear energy transfer (LET) also showed a peak-shaped distribution. To understand the physical process during DNA strand breaks, a Monte Carlo calculation code known as TRIM (Transport of Ions in Matter) was used to simulate energy losses due to nuclear stopping and to electronic stopping. It can be assumed that nuclear stopping plays a more important role in DNA strand breaks than electronic stopping in this energy range. The physical mechanisms of DNA strand breaks induced by a low-energy ion beam are also discussed. Received: 30 July 1997 / Accepted in revised form: 18 January 1998  相似文献   

6.
Accelerated helium ions with mean energies at the target location of 3-7 MeV were used to simulate alpha-particle radiation from radon daughters. The experimental setup and calibration procedure allowed determination of the helium-ion energy distribution and dose in the nuclei of irradiated cells. Using this system, the induction of DNA double-strand breaks and their spatial distributions along DNA were studied in irradiated human fibroblasts. It was found that the apparent number of double-strand breaks as measured by a standard pulsed-field gel assay (FAR assay) decreased with increasing LET in the range 67-120 keV/microm (corresponding to the energy of 7-3 MeV). On the other hand, the generation of small and intermediate-size DNA fragments (0.1-100 kbp) increased with LET, indicating an increased intratrack long-range clustering of breaks. The fragment size distribution was measured in several size classes down to the smallest class of 0.1-2 kbp. When the clustering was taken into account, the actual number of DNA double-strand breaks (separated by at least 0.1 kbp) could be calculated and was found to be in the range 0.010-0.012 breaks/Mbp Gy(-1). This is two- to threefold higher than the apparent yield obtained by the FAR assay. The measured yield of double-strand breaks as a function of LET is compared with theoretical Monte Carlo calculations that simulate the track structure of energy depositions from helium ions as they interact with the 30-nm chromatin fiber. When the calculation is performed to include fragments larger than 0.1 kbp (to correspond to the experimental measurements), there is good agreement between experiment and theory.  相似文献   

7.
8.
The purpose of the present study was to evaluate the dependence of the OH radical yield on the atomic number and the energy of the heavy ions to understand chemical reactions of aqueous solutions. The total yields of oxidized products from phenol in water increased superlinearly as the incident energy increased from 5 MeV/nucleon to 18 MeV/nucleon for carbon and neon ions. The radiolytic yields of OH radicals produced by the ions were determined by analyzing the relationships of the oxidation yields of phenol to the incident energies up to 18 MeV/nucleon for ions in the range of LET from 110 eV/nm to 550 eV/nm and from 320 eV/nm to 1100 eV/nm for carbon and neon ions, respectively. The yields of the OH radicals increased with the specific energy for the same kind of ion and decreased with the atomic number for different ions used at the same specific energy.  相似文献   

9.
10.
This study is based on our already published experimental data (Kowalska et al. in Radiat Environ Biophys 58:99–108, 2019) and is devoted to modeling of chromosome aberrations in human lymphocytes induced by 22.1 MeV/u 11B ions, 199 MeV/u 12C ions, 150 MeV and spread-out Bragg peak (SOBP) proton beams as well as by 60Co γ rays. The curvature of the dose–effect curves determined by the linear-quadratic model was considered in the frame of a simple analytical approach taking into account increase in the irradiation dose due to overlapping interaction regions of ion tracks. The model enabled to estimate effective interaction radius which could be compared with the physical expectations. The results were also compared to the Amorphous Track Structure Model of Katz which allows to get some additional information about the ion track structure. The analysis showed that the curvature of the experimental dose–effect curves mainly results from highly efficient repair processes of the DNA damage.  相似文献   

11.
The biophysical radiation track simulation model PARTRAC was improved by implementing new interaction cross sections for protons in water. Computer-simulated tracks of energy deposition events from protons and their secondary electrons were superimposed on a higher-order DNA target model describing the spatial coordinates of the whole genome inside a human cell. Induction of DNA double-strand breaks was simulated for proton irradiation with LET values between 1.6 and 70 keV/microm and various reference radiation qualities. The yield of DSBs after proton irradiation was found to rise continuously with increasing LET up to about 20 DSBs per Gbp and Gy, corresponding to an RBE up to 2.2. About half of this increase resulted from a higher yield of DSB clusters associated with small fragments below 10 kbp. Exclusion of experimentally unresolved multiple DSBs reduced the maximum DSB yield by 30% and shifted it to an LET of about 40 keV/microm. Simulated fragment size distributions deviated significantly from random breakage distributions over the whole size range after irradiation with protons with an LET above 10 keV/microm. Determination of DSB yields using equations derived for random breakage resulted in an underestimation by up to 20%. The inclusion of background fragments had only a minor influence on the distribution of the DNA fragments induced by radiation. Despite limited numerical agreement, the simulations reproduced the trends in proton-induced DNA DSBs and fragment induction found in recent experiments.  相似文献   

12.
Radiotherapy with protons and carbon ions enables to deliver dose distributions of high conformation to the target. Treatment with helium ions has been suggested due to their physical and biological advantages. A reliable benchmarking of the employed physics models with experimental data is required for treatment planning. However, experimental data for helium interactions is limited, in part due to the complexity and large size of conventional experimental setups.We present a novel method for the investigation of helium interactions with matter using miniaturized instrumentation based on highly integrated pixel detectors. The versatile setup consisted of a monitoring detector in front of the PMMA phantom of varying thickness and a detector stack for investigation of outgoing particles. The ion type downstream from the phantom was determined by high-resolution pattern recognition analysis of the single particle signals in the pixelated detectors. The fractions of helium and hydrogen ions behind the used targets were determined. As expected for the stable helium nucleus, only a minor decrease of the primary ion fluence along the target depth was found. E.g. the detected fraction of hydrogen ions on axis of a 220 MeV/u 4He beam was below 6% behind 24.5 cm of PMMA. Monte-Carlo simulations using Geant4 reproduce the experimental data on helium attenuation and yield of helium fragments qualitatively, but significant deviations were found for some combinations of target thickness and beam energy.The presented method is promising to contribute to the reduction of the uncertainty of treatment planning for helium ion radiotherapy.  相似文献   

13.
The ability of Ehrlich ascites tumor cells (EAT cells) to repair potentially lethal damage (alpha-PLD) as demonstrated by either an increase in survival after delayed plating or a decrease in survival after treatment with beta-arabinofuranosyladenine (beta-araA) was investigated after exposure to protons, deuterons, 3He, 4He, and heavy ions of various specific energies. A significant amount of repair or fixation was observed after delayed plating or treatment with beta-araA, respectively, in cells that were exposed to protons of 6-21 MeV energy, reflecting mainly variations in the survival curve shoulder width. Four-hour treatment with 80 microM/liter beta-araA resulted in an exponential survival curve for all proton energies tested. A decrease in particle energy increased killing and caused a reduction in Dq without a significant change in D0. The survival curve obtained after exposure of cells to 3.4 MeV protons had only a small shoulder and was only slightly modified by either delayed plating or treatment with beta-araA, suggesting a decrease in the induction rate of alpha-PLD. Similar results were also obtained after exposure to deuterons and 4He ions. The results are interpreted as indicating the importance of the specific particle energy and the delta-electron spectrum in the induction of alpha-PLD. When the results of delayed plating of cells exposed to protons, deuterons, or helium ions were pooled, an exponential relationship between Dq and penumbra radius was indicated. After exposure to 40Ar ions of 18 MeV specific energy, a shouldered survival curve was obtained, and beta-araA significantly enhanced killing by modifying Dq as well as D0, a result that also suggests induction of repairable damage by the delta particles produced and interaction of lesions induced within the core of the ion path with penumbra lesions. Based on these results a model is proposed assuming that alpha-PLD results from interaction, during the course of repair, of pairs of DNA lesions induced within a distance di. The model assumes the existence of a critical separation distance dic, with the property that pairs of lesions induced with separation distance shorter than dic (expressed as number of base pairs) will always be expressed as lethal, and the existence of a maximum separation distance dim, with the property that pairs of lesions induced with separation distance larger than dim will not interact.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

14.
This paper describes the irradiation of thin samples of blood with 8.7 MeV protons and 23.5 MeV helium-3 ions in the track segment mode. Chromosome aberrations in human lymphocytes have been scored. The relationship between dicentric yield and dose in Gy was Y = 0.044 D + 0.058 D2 for protons and Y = 0.394 D for helium ions. These results are compared with data from other laboratories using protons and an attempt is made to reconcile differences. An unexpected observation was that the ratio of the linear coefficients for helium ions and protons was about 9 whereas the ratio of the l.e.t. values was 4.5. This disagrees with current theory which predicts that the linear coefficients should be proportional to l.e.t. Possible sources of error in our experiments are discussed but do not adequately account for the discrepancies.  相似文献   

15.
Accelerator-based measurements and model calculations have been used to study the heavy-ion radiation transport properties of materials in use on the International Space Station (ISS). Samples of the ISS aluminum outer hull were augmented with various configurations of internal wall material and polyethylene. The materials were bombarded with high-energy iron ions characteristic of a significant part of the galactic cosmic-ray (GCR) heavy-ion spectrum. Transmitted primary ions and charged fragments produced in nuclear collisions in the materials were measured near the beam axis, and a model was used to extrapolate from the data to lower beam energies and to a lighter ion. For the materials and ions studied, at incident particle energies from 1037 MeV/nucleon down to at least 600 MeV/nucleon, nuclear fragmentation reduces the average dose and dose equivalent per incident ion. At energies below 400 MeV/nucleon, the calculation predicts that as material is added, increased ionization energy loss produces increases in some dosimetric quantities. These limited results suggest that the addition of modest amounts of polyethylene or similar material to the interior of the ISS will reduce the dose to ISS crews from space radiation; however, the radiation transport properties of ISS materials should be evaluated with a realistic space radiation field.  相似文献   

16.
The biological effects of irradiation with ions of masses larger than 40 and energies up to 20 MeV per atomic mass unit are reviewed. The objects are viruses, bacterial spores, yeast and mammalian cells. Experimental parameters include loss of colony forming ability, induction of mutants, chromosomal aberrations, cell cycle progression, inhibition of biochemical activities and the formation of strand breaks. Some of the pertinent physical questions--e.g. track structure--are also discussed. It is shown that with very heavy ions the biological effectiveness is no longer unambiguously related to a single parameter like l.e.t. or Z*2/beta 2 but depends strongly on ion energy. This points to the importance of far-reaching delta-electrons. The analysis indicates also that even with very high l.e.t., cells are not killed by the passage of a single particle through their nucleus. Possible implications of the findings for fundamental radiation biology are outlined.  相似文献   

17.
Ionizing radiation-induced bystander effects, commonly observed in cell populations exposed to high-linear energy transfer (LET) radiations, are initiated by damage to a cellular molecule which then gives rise to a toxic signal exported to neighboring cells not directly hit by radiation. A major goal in studies of this phenomenon is the identification of this initial radiation-induced lesion. Liquid water being the main constituent of biological matter, reactive species produced by water radiolysis in the cellular environment are likely to be major contributors to the induction of this lesion. In this context, the radiation track structure is of crucial importance in specifying the precise location and identity of all the radiolytic species and their subsequent signaling or damaging effects. We report here Monte Carlo track structure simulations of the radiolysis of liquid water by four different impacting ions 1H+, 4He2+, 12C6+ and 20Ne10+, with the same LET ( approximately 70 keV/ microm). The initial radial distribution profiles of the various water decomposition products (eaq(-), *OH, H*, H2 and H2O2) for the different ions considered are presented and discussed briefly in the context of track structure theory. As an example, the formation and temporal evolution of simulated 24 MeV 4He2+ ion tracks (LET approximately 26 keV/microm) are reported for each radiolytic species from 1 ps to 10 micros. The calculations reveal that the ion track structure is completely lost by approximately 1 micros.  相似文献   

18.
The spatial distribution of DNA double-strand breaks (DSB) was assessed after treatment of mammalian cells (V79) with densely ionizing radiation. Cells were exposed to beams of heavy charged particles (calcium ions: 6.9 MeV/u, 2.1⋅103 keV/μm; uranium ions: 9.0 MeV/u, 1.4⋅104 keV/μm) at the linear accelerator UNILAC of GSI, Darmstadt. DNA was isolated in agarose plugs and subjected to pulsed-field gel electrophoresis under conditions that separated DNA fragments of size 50 kbp to 5 Mbp. The measured fragment distributions were compared to those obtained after γ-irradiation and were analyzed by means of a convolution and a deconvolution technique. In contrast to the finding for γ-radiation, the distributions produced by heavy ions do not correspond to the random breakage model. Their marked overdispersion and the observed excess of short fragments reflect spatial clustering of DSB that extends over large regions of the DNA, up to several mega base pairs (Mbp). At fluences of 0.75 and 1.5/μm2, calcium ions produce nearly the same shape of fragment spectrum, merely with a difference in the amount of DNA entering the gel; this suggests that the DNA is fragmented by individual calcium ions. At a fluence of 0.8/μm2 uranium ions produce a profile that is shifted to smaller fragment sizes in comparison to the profile obtained at a fluence of 0.4/μm2; this suggests cumulative action of two separate ions in the formation of fragments. These observations are not consistent with the expectation that the uranium ions, with their much larger LET, should be more likely to produce single particle action than the calcium ions. However, a consideration of the greater lateral extension of the tracks of the faster uranium ions explains the observed differences; it suggests that the DNA is closely coiled so that even DNA locations several Mbp apart are usually not separated by less than 0.1 or 0.2 μm. Received: 27 January 1998 / Accepted in revised form: 15 April 1998  相似文献   

19.
Introduction: Cyclotron-based proton therapy facilities use an energy degrader of variable thickness to deliver beams of the different energies required by a patient treatment plan; scattering and straggling in the degrader give rise to an inherent emittance increase and subsequent particle loss in the downstream energy-selection system (ESS). Here we study alternative graphite degrader geometries and examine with Monte-Carlo simulations the induced emittance growth and consequent particle transmission.Methods: We examined the conventional multiple-wedge degrader used in the Paul Scherrer Institute PROSCAN proton therapy system, the equivalent parallel-sided degrader, and a single block degrader of equivalent thickness. G4Beamline Monte-Carlo tracking of protons was benchmarked against measurements of the existing degrader for proton energies from 75 to 230 MeV, and used to validate simulations of the alternative geometries.Results: Using a careful calculation of the beam emittance growth, we determined that a single-block degrader placed close to the collimators of the ESS is expected to deliver significantly larger transmission, up to 17% larger at 150 MeV. At the lowest deliverable of 75 MeV there is still a clear improvement in beam transmission.Conclusions: Whilst dose rates are not presently limited on the PROSCAN system at higher energies, a single-block degrader offers the ability to access either lower energies for treatment or a larger dose rate at 75 MeV in case transmission optimisation is desired. Single-block degraders should be considered for the delivery of low-energy protons from a cyclotron-based particle therapy system.  相似文献   

20.
An analytical expression is developed for calculating the average energy deposited by an ion in a volume with dimensions less than the range of the secondary electrons produced. The expression is obtained by including two additional terms in an energy-restricted linear-energy-transfer equation. The usual energy-restricted expression accounts for energy deposited in the volume by energy transfers less than a certain cutoff value. The modified expression, due to the two additional terms, also accounts for energy deposited in the volume which results from energy transfers greater than the cutoff value. The additional terms therefore convert the energy-restricted equation to a distance- or spatially restricted equation. The method is used to obtain radial dose profile information on ion tracks and to calculate the energy deposited by an ion randomly incident upon spherical and hemispherical target sites. Results are in close agreement with more complex methods reported previously for ions with energies from 0.25 to 1000 MeV/amu in volumes of water vapor with dimensions from 1 nm to 10 microns. There are no fitted parameters in this general approach, and all the necessary input data are readily available.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号