首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
IntroductionCurrent guidelines advocate reviewing peri-procedural anticoagulation on individual case basis for transvenous lead extraction (TLE). We investigated the safety of TLE on uninterrupted warfarin with therapeutic INR.MethodsRetrospective registry of consecutive patients undergoing TLE on uninterrupted warfarin (Warfarin Group) across two centres. Age and sex matched controls not on anticoagulation (No-Warfarin Group) and undergoing TLE over the same time-period were included. Both groups were compared over one-year.Results121 TLEs over 18-months. 22 patients on uninterrupted anticoagulation were compared to 22 controls. Groups were well matched for baseline demographics other than INR. Warfarin group had mean INR of 2.2 ± 0.6 (range 2–3.5). Primary end point was procedural safety and efficacy. Amongst cases, 43/45 (96%) leads were removed in their entirety compared to 37/40 (93%) in controls (p = 0.66). In the cases, these included 44% defibrillator, 47% pace-sense and 9% CS leads of average duration 7yrs. There was no reported tamponade, haemothorax or procedural mortality in either group. One patient amongst cases required inotropic support while two patients amongst controls had device-site haematomas. No significant difference reported in Hb drop post-procedure or overall complication rate between the groups (p = 0.11,0.32). Cox regression showed a significant association between procedural success and device infection, number of leads extracted, serum creatinine (p = 0.03, 0.04, 0.02). Over a 1-year follow-up, there was lead displacement in one case and one control had infection of the re-implanted device.ConclusionTLE can be carried out safely in anticoagulated patients with therapeutic INRs. Larger multicentre studies are required to confirm these findings.  相似文献   

2.
Background and objectivesQuadripolar left ventricular (LV) leads in cardiac resynchronization therapy (CRT) offer multi-vector pacing with different pacing configurations and hence enabling LV pacing at most suitable site with better lead stability. We aim to compare the outcomes between quadripolar and bipolar LV lead in patients receiving CRT.MethodsIn this prospective, non-randomized, single-center observational study, we enrolled 93 patients receiving CRT with bipolar (BiP) (n = 31) and quadripolar (Quad) (n = 62) LV lead between August 2016 to August 2019. Patients were followed for six months, and outcomes were compared with respect to CRT response (defined as ≥5% absolute increase in left ventricle ejection fraction), electrocardiographic, echocardiographic parameters, NYHA functional class improvement, and incidence of LV lead-related complication.ResultsAt the end of six months follow up, CRT with quadripolar lead was associated with better response rate as compared to bipolar pacing (85.48% vs 64.51%; p = 0.03), lesser heart failure (HF) hospitalization events (1.5 vs 2; p = 0.04) and better improvement in HF symptoms (patients with ≥1 NYHA improvement 87.09% vs 67.74%; p = 0.04). There were fewer deaths per 100 patient-year (6.45 vs 9.37; p = 0.04) and more narrowing of QRS duration (Δ12.56 ± 3.11 ms vs Δ7.29 ± 1.87 ms; p = 0.04) with quadripolar lead use. Lead related complications were significantly more with the use of bipolar lead (74.19% vs 41.94%; p = 0.02).ConclusionsOur prospective, non-randomized, single-center observational study reveals that patients receiving CRT with quadripolar leads have a better response to therapy, lesser heart failure hospitalizations, lower all-cause mortality, and fewer lead-related complications, proving its superiority over the bipolar lead.  相似文献   

3.
PurposeDespite the developments in conventional transvenous pacemakers (VVI-PM), the procedure is still associated with significant complications. Although there are no prospective clinical trials that compared VVI-PM with transcatheter pacemaker systems (TPS).MethodsThis is a prospective, observational, single-center study that included all patients with an indication for a single-chamber pacemaker implant within a 4-year period. All clinical, ECG and echocardiographic characteristics at implant, electrical parameters, associated complications and mortality were analyzed. A Cox survival model and a Bayesian cohort analysis were performed for differences in complication rates between groups.ResultsThere were 443 patients included (198 TPS and 245 VVI-PM). The mean age was 81.5 years (TPS group, 79.2 ± 6.6 years; VVI-PM group, 83.5 ± 8.9 years). There was a male predominance in TPS group (123, 62.1% vs. 67, 27.3%; p < 0.001). The presence of systolic dysfunction and renal insufficiency were more frequent in VVI-PM group than in TPS patients. Mean follow-up was 22.3 ± 15.9 months. In a multivariable paired data the TPS group presented fewer complications than VVI-PM group (HR = 0.39 [0.15–0.98], p-value 0.013), but major complications were not different (6, 3% vs 14, 5.6% respectively, p = 0.1761). There was no difference in the mortality rate between the groups. The TPS group had less risk than VVI-PM group to have a complication, with a 96% of probability.ConclusionsTPS patients had a lower overall complication rate than VVI-PM patients including matched-pair samples using a Bayesian analysis. These results confirm the safety profile of TPS in clinical practice.  相似文献   

4.
BackgroundData from large-volume centers in developed countries, using dedicated tools, show a high success rate with a good safety record for the percutaneous lead removal procedure. However, there are constraints to replicate the results in a resource-poor setting and there is limited data from India.MethodsWe retrospectively analyzed lead removal procedures performed in our institution from 2008 to 2019.ResultsSeventy-five patients underwent percutaneous removal of 138 leads. Of these, 44 procedures and 80 leads qualified as extraction with a median dwell time of 52.1 (IQR 28.2–117.2) months. Overall, 33/44 (75.0%) procedures were successful and 65/80 (81.2%) leads were successfully extracted. Manual traction was successful in the extraction of 44/57 (77.2%) leads. All leads implanted less than 2.7 years could be removed with manual traction alone. Specialized tools were used in 23 leads and 21 (91.3%) of those could be successfully extracted. Inability to use dedicated tools was an independent predictor of procedural failure (adjusted OR 14.0; 95% CI 1.8–110.2; p-value 0.012). Right-sided implant (adjusted OR 12.6; 95% CI 1.3–119.5; p-value 0.027) was also independently associated with failure. There was 1 death (1.3%) and minor complications occurred in 6 (8.0%) patients.ConclusionsIn a resource-limited setting, percutaneous lead extraction of predominantly pacemaker leads by manual traction methods achieved success in extracting about three-fourths of the leads. Inability to use specialized tools was the main factor limiting success. The complication rate was low.  相似文献   

5.
PurposeOxygen extraction fraction (OEF) can be a factor to identify brain tissue’s disability in epileptic patients. This study aimed to assess the OEF’s level measurement in refractory epileptic patients (REPs) using a quantitative susceptibility mapping (QSM) method and to determine whether the OEF parameters change.MethodsQSM-OEF maps of 26 REPs and 16 healthy subjects were acquired using 3T MRI with a 64-channel coil. Eighteen regions-of-interest (ROIs) were chosen around the cortex in one appropriate slice of the brain and the mean QSM-OEF for each ROI was obtained. The correlations of QSM-OEF among different clinical characteristics of the disease, as well as between the patients and normal subjects, were also investigated.ResultsQSM-OEF was shown to be significantly higher in REPs (44.9 ± 5.8) than that in HS (41.9 ± 6.2) (p < 0.05). Mean QSM-OEF was statistically lower in the ipsilateral side (44.5 ± 6.6) compared to the contralateral side (46.4 ± 6.8) (P < 0.01). QSM-OEF was illustrated to have a strong positive correlation with the attack duration (r = 0.6), and a moderate negative correlation with the attack frequency (r = −0.3). Using an optimized support vector machine algorithm, we could predict the disease in subjects having abnormal OEF values in the brain-selected-ROIs with sensitivity, specificity, AUC, and the precision of 0.96, 1, 0.98, and 1, respectively.ConclusionsThe results of this study revealed that QSM-OEF of the REPs’ brain is higher than that of HS, which indicates that QSM-OEF is associated with disease activity.  相似文献   

6.
PurposeThe Biotronik LinoxSmart DX implanted cardioverter defibrillator (ICD) lead is a novel VDD lead with the advantage of integrated atrial sensing dipole combined with a special augmentation and filtering mechanisms. We sought to determine the efficacy of the Biotronik LinoxSmart DX ICD lead.MethodsNon-randomized consecutive patients implanted with Biotronik LinoxSmart DX lead at Sheba Medical Center were included in this study. Electrical parameters and arrhythmic events were recorded during follow up of one year.ResultsSeventy-three patients (69 males (94.5%), mean age 61 ± 12 years) were included. All patients were successfully implanted with a Biotronic VR-T DX device and LinoxSmart DX ICD lead (DX-17 in 37% and DX-15 in 63% patients). Mean P wave amplitude at time of implantation was 3.66 ± 2.9 mV and improved significantly throughout the follow-up (5.29 ± 4.39 mV, p = 0.009). Appropriate atrial sensing (defined as P wave amplitude of ≥0.8 mV) rate of 100% at implantation significantly decreased to 89% (p = 0.015) at 12 months. Three out of 67 (4.5%) patients without a known history of atrial fibrillation had documented new onset paroxysmal atrial fibrillation. Appropriate shocks occurred in 4 (5.5%) patients. One patient with atrial sensing less than 0.4 mV had inappropriate shock.ConclusionsAmong patients implanted with the Biotronik LinoxSmart DX ICD lead in our single center, appropriate atrial sensing rate decreased over 12 months. Larger studies are needed to evaluate the reliability of long term appropriate atrial sensing.  相似文献   

7.
BackgroundUltrasound-guided axillary venous puncture (UGAVP) for cardiac devices implantation has been developed because of its rapidity, safety and potential long-term lead protection. Early work excluded defibrillators (ICD), cardiac resynchronization therapy (CRT) and upgrade procedures. Compared to the cephalic approach, in previous studies, there was a greater use of pressure dressings with this technique, suggesting a higher risk of bleeding.AimsTo assess UGAVP in patients under antithrombotic therapy (ATT) undergoing cardiac devices implantation including CRT/ICD.MethodsProspectively, consecutive patients eligible for a pacemaker or ICD implantation were included. All procedures were performed by a single operator, experienced with UGAVP for femoral access, and fluoroscopy-guided axillary vein access. Guidewires insertion time (from lidocaïne administration), and complications were systematically studied.ResultsFrom 457 cardiac device implantations, 200 patients (77.8 ± 10 y, male 58%) 360 leads were implanted by UGAVP including 36 ICD, 54 CRT and 14 upgrade procedures. A majority (90%) was under ATT: Vitamin K Antagonist or Heparin (n = 58, 29%), direct oral anticoagulant (n = 46, 23%), dual antithrombotic therapy (n = 18, 9%) and single antiplatelet drug (n = 82, 41%). UGAVP was successful in 95.78%. Mean insertion time for 1.8 guidewires per patient was 4.68 ± 3.6 min. No complication (no hematoma) was observed during the follow-up (mean of 45 ± 10 months). Guidewires insertion time reached its plateau after 15 patients.ConclusionUGAVP is fast, feasible and safe for patients under ATT undergoing device implantation including CRT/ICD and upgrade procedures, with a short learning curve.  相似文献   

8.
BackgroundThe leadless pacemaking transcatheter system, Micra, is a miniaturized, single-chamber pacemaker system. We report herein our experience with implantation of the Micra TPS system.ObjectiveThe current study was conducted to evaluate the safety and efficacy of the leadless Micra Transcatheter Pacemaker System (Medtronic).Research design and methodsThis was a prospective single centre nonrandomized study without controls. A transcatheter pacemaker was implanted in patients who had guideline based indications for ventricular pacing. 28 subjects were screened based on the selection criteria. Mica TPS was implanted. Parameters assessed were: duration of procedure (from femoral vein puncture to venous access closure), fluoroscopy time, number of device repositions, periprocedural electrical measurements (sensing, threshold and impedance) and in-hospital, intermediate to long term adverse events related to procedure.Result and conclusions: The device was successfully implanted in 28 subjects. The mean intraoperative sensing value was 9.04 ± 1.5 mV and the impedance was 766.89 ± 213.9 Ω. At discharge from hospital, those values were 13.2 ± 15.83 mV and 855 ± 111.7, respectively. The recommended pacing threshold value as achieved in all subjects was 0.78 V, i.e. ≤ 1 V at 0.24 ms. There was no adverse event or complications reported for any of the subjects. Mean time from hospitalization to discharge was 1.5 days. Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system.  相似文献   

9.
ObjectivesComparison of outcomes, device deployment time (DT), and total time (TT) using a single tapered Coons dilator versus sequential serial dilation for implantation of the Micra leadless pacemaker.BackgroundMicra leadless pacemaker placement requires a 23 French Micra introducer sheath (MIS) for percutaneous delivery. We sought to evaluate outcomes with use of a single tapered Coons dilator (CD) versus sequential serial dilatation (SD) method to facilitate insertion of the Micra introducer sheath.Methods35 patients were included in the SD arm and 49 in the CD arm. DT and TT were recorded in minutes and cost in dollars. Analysis was performed using independent t-test between two groups and one-way ANOVA to evaluate inter-operator variability in the CD arm.ResultsBoth DT and TT were significantly lower for the CD arm (15.1 ± 5.1 vs 23.5 ± 9.3, p < 0.0005 and 29.9 ± 14 vs 39.3 ± 13.5 min, p = 0.000374; respectively). The cost was also significantly lower using a CD versus SD. There was no inter-operator variability in the CD arm between 6 operators (p = 0.177 for DT and p = 0.304 for TT). No complications occurred in the SD arm. There were 3 vascular access site complications in the CD arm, all of which occurred early in the operator’s experience.ConclusionCoons dilator is an efficient and cost-effective method for vascular dilatation to facilitate Micra leadless pacemaker insertion. Rate of complications is low and expected to improve with greater experience.  相似文献   

10.
BackgroundSecond-generation cryoballoon ablation is safe and effective in patients with paroxysmal (PAF) and persistent atrial fibrillation (AF).ObjectiveThis study aimed to assess the long-term clinical outcomes and freedom from AF in patients undergoing thermal-guided cryoablation without the use of an electrical mapping catheter.MethodsAll patients who had undergone thermal-guided second-generation cryoablation without electrical mapping between January 2015 and April 2018 at Eastbourne District General Hospital were retrospectively analysed. Success was defined as freedom from atrial arrhythmia lasting >30 s during the follow up period.ResultsThe study included 234 patients with a mean age of 65.3 ± 10.6 years. There were 134 (57.0%) and 100 (42.7%) patients who had PAF and persistent AF respectively.Arrhythmia recurrence occurred in 38 of 134 (28.4%) PAF and 42 of 100 (42.0%) persistent AF patients after mean follow up of 40 ± 9.2 months. The patients with PAF had a significantly greater freedom from arrhythmia than patients with persistent AF (p = .040). The mean procedure time was 55.5 ± 12.2 min and the mean fluoroscopy time was 10.9 ± 4.8 min 73.5% of patients were discharged on the same day.ConclusionThermal-guided cryoablation is feasible, safe and results in freedom from arrhythmia in the majority of paroxysmal and persistent AF patients in the long term. Randomised controlled trials are required to confirm the findings of this study.  相似文献   

11.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   

12.
《Endocrine practice》2012,18(5):720-726
ObjectiveTo determine whether laparoscopic adrenalectomy in patients without radiologic evidence of cancer compromises the perioperative and long-term outcomes in patients with large (≥ 6 cm) pheochromocytomas.MethodsWe analyzed a prospective adrenal database of consecutive patients who underwent adrenalectomy at our institution between September 2000 and September 2010. Patients with diagnosed pheochromocytoma who underwent laparoscopic adrenalectomy were included. Patients with tumors smaller than 6 cm were compared with those presenting with tumors 6 cm or larger.ResultsOne hundred fifty-seven patients underwent adrenalectomy, and there were 32 catecholamine-secreting tumors. Of the 33, 7 were excluded from the study because of open surgery. Thus, 25 patients presented with 26 pheochromocytomas and underwent laparoscopic adrenalectomy. Thirteen of the 25 patients (52%) were women. Mean age (± standard error of the mean) was 53 ± 3 years. Mean tumor size was 5.2 ± 0.5 cm, and 11 pheochromocytomas (42%) were 6 cm or larger. Tumor size was significantly different between the large pheochromocytoma and the small pheochromocytoma groups (7.6 ± 0.4 vs 3.6 ± 0.4 cm, P <.001), but there was no significant difference in intraoperative complications, estimated blood loss, cancer diagnosis, or recurrence. The length of stay was comparable between the 2 cohorts, and there were no incidents of capsular invasion or adverse cardiovascular events.ConclusionLaparoscopic adrenalectomy of pheochromocytomas larger than 6 cm is feasible and safe with comparable results to those achieved with laparoscopic adrenalectomy in patients with smaller pheochromocytomas. (Endocr Pract. 2012;18:720-726)  相似文献   

13.
ObjectiveTo examine the learning curves of atrial fibrillation (AF) ablation comparing the cryoballoon (CB) and radiofrequency (RF) catheters.MethodsWe performed a retrospective data analysis from the initiation of AF ablation program in our center. For CB ablation, a second generation 28 mm balloon was utilized and for RF ablation.ResultsA total of 100 consecutive patients (50 in each group) have been enrolled in the study (male 74%, mean age 58.9 ± 10 years, paroxysmal AF 85%). The mean procedure time was shorter for CB (116.6 ± 39.8 min) than RF group (191.8 ± 101.1 min) (p < 0.001). There was no difference in the mean fluoroscopy time, 24.2 ± 10.6 min in RF and 22.4 ± 11.7 min in CB group, (p = 0.422). Seven major complications occurred during the study; 5 in RF group (10%) and 2 in CB group (4%) (p = 0.436). After the mean follow up of 14.5 ± 2.4 months, 15 patients in RF group (30%) and 11 in CB group (26%) experienced AF recurrences (P = 0.300).ConclusionWhen starting a new AF ablation program, our results suggest that CB significantly shortens procedure while fluoroscopy time and clinical outcomes are comparable to RF ablation.  相似文献   

14.
BackgroundImplantation of coronary sinus (CS) leads may be a difficult procedure due to different vein anatomies and a possible lead dislodgement. The mode of CS lead fixation has changed and developed in recent years.ObjectivesWe compared the removal procedures of active and passive fixation leads.MethodsBetween January 2009 and January 2014, 22 patients at our centre underwent CS lead removal, 6 active and 16 passive fixation leads were attempted using simple traction or lead locking devices with or without laser extraction sheaths. Data on procedural variables and success rates were collected and retrospectively analyzed.ResultsThe mean patient age was 67.2 ± 9.8 years, and 90.9% were male. The indication for lead removal was infection in all cases. All active fixation leads were Medtronic® Attain StarFix Model 4195 (Medtronic Inc., Minneapolis, MN, USA). The mean time from implantation for the active and passive fixation leads was 9.9 ± 11.7 months (range 1.0–30.1) and 48.7 ± 33.6 months (range 5.7–106.4), respectively (p = 0.012). Only 3 of 6 StarFix leads were successfully removed (50%) compared to 16 of 16 (100%) of the passive fixation CS leads (p = 0.013). No death or complications occurred during the 30-day follow-up.ConclusionAccording to our experience, removal of the Starfix active fixation CS leads had a higher procedural failure rate compared to passive.  相似文献   

15.
BackgroundThe wearable cardioverter-defibrillator (WCD) has been approved for patients with poor left ventricular ejection fraction (LVEF) who are at risk of sudden arrhythmic death for a limited period but are not candidates for a definitive implantable cardioverter-defibrillator (ICD). The present study sought to retrospectively analyse our single-centre experience.Methods and resultsAll consecutive WCDs applied between April 2017 and September 2018 in our centre were enrolled. An exercise test was performed in all patients in order to evaluate the absence of false detection of ventricular arrhythmias by the device. A total of 16 patients (57.7 ± 14.8 years old; 75% males) were taken into consideration for the analysis. Mean LVEF was 32 ± 11% at diagnosis and 42 ± 10% at last follow-up (mean, 3.1 ± 1.7 months; median, 3 months). At the end of the “wearing period” 11/16 patients (69%) did not have ICD implant indications and only 5 (31%) underwent ICD implantation. Neither appropriate nor appropriate shocks occurred during the follow up.ConclusionsThe WCD represents a useful tool to bridge a temporarily increased risk for sudden cardiac death. The proportion of patients with an improvement of LVEF> 35% beyond the WCD-application period was considerable.  相似文献   

16.
《Endocrine practice》2009,15(3):213-219
ObjectiveTo evaluate the effectiveness of gamma probe performed with technetium Tc 99m–labeled pertechnetate in patients who underwent completion thyroidectomy after pathologic detection of incidental thyroid cancer following subtotal thyroidectomy.MethodsIn this prospective study, we evaluated findings from patients with multinodular goiter who underwent gamma probe–guided lateral approach completion thyroidectomy after the pathologic detection of incidental thyroid cancer following subtotal thyroidectomy where partial thyroid tissue was left unilaterally or bilaterally. Patients who underwent the procedure between January 2003 and January 2007 were included. Thyroid scintigraphy; thyroid and neck ultrasonography examinations; and concentrations of thyroid hormones, thyrotropin (TSH), thyroglobulin, and thyroglobulin antibodies were evaluated before the second operation. Patients were administered 3 mCi technetium Tc 99m pertechnetate during anaesthetic induction, and we extracted suspicious thyroid tissue and tissue with activity above background activity levels according to gamma probe. Extracted tissues were evaluated pathologically.ResultsCompletion thyroidectomy was performed in 23 patients. Seventy-nine tissue samples were extracted; 49 were thyroid tissue and 30 were nonthyroid tissue. Mean thyroid tissue to background activity ratio (T:B) was 6.4 ± 3.9 (range, 2-14.3), and mean thyroid bed (after excision) to background activity ratio (Tbed:B) was 1.2 ± 0.2 (range, 0.8-1.7) (P = .001). Mean T:B and Tbed:B ratios of the nonthyroid tissue were 1.2 ± 0.3 (range, 0.2-1.7) and 1.1 ± 0.2 (range, 0.4-1.4), respectively (P = .001). The thyroid tissue T:B ratio was significantly higher than that of nonthyroid tissue (P < .001). Gamma probe labeling contributed to extraction of small amounts of thyroid tissue that could not be viewed by scintigraphy in 43% of patients.ConclusionsUsing gamma labeling, thyroid tissue shows significantly more activity than nonthyroid tissue. Gamma probe helps detect small, residual thyroid tissue that is buried in the scar tissue that cannot be distinguished by scintigraphy; therefore, it assists in the extraction of the maximum amount of thyroid tissue. (Endocr Pract. 2009;15:213-219)  相似文献   

17.
A popular sequential extraction procedure (Tessier et al. 1979) designed t o extract metals partitioned in various sediment phases, was evaluated for its selectivity. Amorphous FeOOH, FeS, and FeS2 were added separately to natural lake sediments and sequentially extracted. The selectivity of the sequential procedure for the added solid phases was evaluated by determining the difference in the mass of Fe extracted from treated and control sediments. In the experiments where sulfide minerals were added, total S was measured in the residual solids in order to confirm selectivity of the method. Concentrations of total carbon remaining in the solid phase after each extraction step were also measured to determine the selectivity of the sequential procedure for carbon. The procedure was moderately selective for Fe added as FeOOH; a mean of 77 ± 12% (p < 0.05) of the Fe added was extracted in the step designed to reduce Fe-Mn oxyhydroxides. In experiments where FeS was added, a mean of 69 ± 11% (p < 0.05) of the Fe added as FeS was extracted in the fraction designed to oxidize sulfides and organic matter. Approximately 25% of the Fe added as FeS may have been extracted prematurely. Although less precise, total S analyses confirmed that much of the FeS was extracted in the oxidation step, yielding 104 ± 87% (p < 0.05) of the S added as FeS. The procedure was highly selective for FeS2; 92 ± 14% (p < 0.05) of the Fe added as pyrite was extracted in the sulfide extraction step. Extraction of 80 ± 54% (p < 0.05) of S added as pyrite confirmed that FeS2 were selectively extracted in the sulfide extraction step. Carbon in the sediments was also selectively extracted in the oxidation step (77 ± 2.4% of total C; p < 0.05). The applications and limitations of sequential extraction procedures as limnological research tools are discussed in light of our results. Request for offprints  相似文献   

18.
AimTo compare the angular changes of the third molars relative to the occlusal plane and to the second molar long axis in extraction group and compare these changes with a non extraction group.Materials and methodsThe study included pre and post treatment panoramic radiograph records of 90 subjects treated by first premolar extractions and 90 subjects who had been treated with non extraction orthodontic therapy (n = 90). Two angular variables were measured. Firstly, the angle between the long axis of the third molar and the occlusal plane (M3–OP) and secondly, the angle between the long axis of the third molar and the long axis of the second molar (M3–M2). Data were analyzed by paired and student’s t-test.ResultThe analyzed data to assess the changes in the third molar angulation from pretreatment to post treatment did not vary significantly in both the groups (p < 0.05). Both the groups showed decreased angular values. The M3–OP angular difference was (−7.3 ± 2.45) in extraction group as compared to (−5.85 ± 1.77) in non extraction group. The M3–M2 angular difference of (−4.26 ± 3.11) in extraction group and (−2.98 ± 1.74) in non-extraction group was observed.ConclusionExtraction of premolars did not demonstrate considerable changes on the angulation of the third molars. The factors other than premolar extractions may influence the angulation of the third molars.  相似文献   

19.

Introduction

The number of pacemaker and ICD implantations has increased substantially in the recent years. Therefore, complications are also observed in a greater number. In many cases, transvenous extraction of the previously implanted device (pacemaker or ICD) is the only solution. One may find in the literature information about the efficacy and safety of that procedure, but data concerning the results of long-term follow up are still limited.

Aim

The aim of the study was to assess the one-year mortality in the cohort of patients undergoing transvenous lead extraction procedures in our centre.

Methods

Records of the patients undergoing transvenous lead removal in the Department of Cardiology and Electrotherapy of the Medical University of Gdańsk were analyzed. We collected detailed information about 192 patients that had undergone the procedure from January 2003 until June 2012. Data were collected from medical and surgical records. We analyzed concomitant diseases, indications, and possible complications. Long-term follow-up data were gathered in the follow-up ambulatory records and over-the-phone interviews with patients or families. In several cases, we consulted the database of the Polish National Health Fund.

Results

During the early post-operative period 5 patients died, although none of those deaths was associated with the procedure itself. No other major complications were observed. During one-year follow-up other 5 patients died, which gave the overall one-year survival rate of 92.7%. Heart failure, renal failure and an infective indication showed significant association with increased mortality.

Conclusion

Results of transvenous lead extraction, a relatively safe procedure, should be assessed over time extending beyond the sole perioperative period. Some complications may be delayed in their nature, and may be observed only during the long-term follow up.  相似文献   

20.
ObjectiveTo determine the nature of adrenal pathology in patients undergoing adrenalectomy in Saudi Arabia over the last decade and compare it with the literature. We compared perioperative outcomes between minimally invasive adrenalectomy (MIA) and open adrenalectomy (OA).MethodsThis retrospective study included patients who underwent adrenalectomy at five tertiary care centers in Saudi Arabia from 2010 to 2020. We collected patients’ baseline and perioperative characteristics and detailed hormonal evaluation of adrenal masses.ResultsAmong 160 patients (mean age 44 ± 14.5 years; mean BMI 29.17 ± 5.96 kg/m2), 84 (51.5 %) were men and 51.5 % had left-sided adrenal masses. The mean tumor size was 6.1 ± 4.2 (1.0–19.5) cm, including 60 (37.5 %) incidentalomas and 65 (40.6 %) functioning masses. Histopathology revealed 74 (46.2 %) adenomas and 24 (15 %) cancers or metastases from other primary organs; 20 %, 8.8 %, and 2.5 % of patients had pheochromocytoma, myelolipoma, and 2.5 % ganglioneuroblastoma, respectively. MIA and OA were performed in 135 (84.4 %) and 21 (15.6 %) patients, respectively. Adrenalectomy was increasingly performed over three equal periods in the last decade (17.5 % vs 34.4 % vs 48.1 %), with increasing numbers of MIAs to replace OAs. OA patients had larger tumors and needed blood transfusion more frequently (47.6 % vs 10.8 %, p< 0.001). MIA was significantly associated with shorter operative time, shorter length of stay, and less blood loss. Postoperative complications occurred in 10 (6.2 %) patients and were significantly higher for OA (24 % vs 3.0 %, p< 0.001).ConclusionsThe majority of adrenal masses are benign. Herein, the observed functional and perioperative outcomes were comparable to those of available meta-analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号