1.
The dosimetric package used inside Biorack on board STS76, STS81 and STS84 comprises passive detector stacks built from plastic nuclear track detectors (PNTDs), thermoluminescence detectors (TLDs) and one or two active DOSTEL (DOSimetric TELescope) units using planar silicon detectors. Five passive detector stacks were exposed at different places inside the BIORACK incubators and in different stowage positions. DOSTEL units were exposed inside the 22 degrees C incubator in all flights. Mission integrated dose measurements, particle fluence rates and neutron doses are obtained from the passive detector stacks. These results are complemented by time resolved particle counts and dose rates and linear energy transfer (LET) spectra separately for the contribution of the trapped particles and the galactic cosmic rays (GCR) as a result of the DOSTEL measurements. In addition, it was possible to investigate the anisotropy of the radiation field inside Biorack by the use of a second DOSTEL unit on STS84. Since all exposures are during a solar minimum period, the total radiation exposure is of a similar extent for all flights, although position differences in dose rate up to a factor of two are observed. Particle fluence rates show lower variations. Mission averaged mean quality factors (Q) determined from the LET spectra are 2.0+/-0.1; the deduced dose equivalent rates range from 631 to 716 microSv/day.  相似文献   

2.
Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.  相似文献   

3.
Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).  相似文献   

4.
The determination of the dose delivered to the body during Total Body Irradiation (TBI) is not easy, as direct measurements are impossible. This article presents the intention to develop a systematic and simple method for absorbed dose determination in(60)Co TBI using mid plane dose factors (MDF) and external measurements, i.e. entrance and exit dose readings by semiconductor detectors. In order to perform the radiation field analysis prior to TBI treatment, a special silicon n-type detector with increased sensitivity (1200 nC/Gy) was used. The dependence of the calibration factor of this detector exposed to different dose rates in standard and TBI conditions was investigated. A theoretical model of anthropomorphic phantoms of cylindrical ellipsoid shape was established. The software made it possible to generalize the applicability of TBI dosimetry to any individual case of real patient data. A quality assurance analysis of dosimetric results of 350 patients, who underwent TBI during a 17-year period, was performed.  相似文献   

5.
The physical composition and intensities of solar particle event exposures of sensitive astronaut tissues are examined under conditions approximating an astronaut in deep space. Response functions for conversion of particle fluence into dose and dose equivalent averaged over organ tissues are used to establish significant fluence levels and the expected dose and dose rates of the most important events from past observations. The BRYNTRN transport code is used to evaluate the local environment experienced by sensitive tissues and used to evaluate bioresponse models developed for use in tactical nuclear warfare. The present results will help to clarify the biophysical aspects of such exposure in the assessment of RBE and dose rate effects and their impact on design of protection systems for the astronauts. The use of polymers as shielding material in place of an equal mass of aluminum would provide a large safety factor without increasing the vehicle mass. This safety factor is sufficient to provide adequate protection if a factor of two larger event than has ever been observed in fact occurs during the mission.  相似文献   

6.
The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.  相似文献   

7.
AimTo evaluate if a radiochromic film (RF) Gafchromic EBT3 is suitable for surface dose measurements of radiotherapy treatments performed with a 6 MV linear accelerator. Two aspects of RF were analyzed, beam energy dependence and surface dose determination.BackgroundThe measurements done at the surface or near the radiation source are done without charged electronic equilibrium and also have contribution of electron contamination. The detectors used for these measurements should not alter the dose to the target. To counteract these dosimetric problems it is proposed to do the measurements with radiochromic films which are thin detectors and have tissue equivalent properties.Materials and MethodsThe measurements were done using a Novalis linear accelerator (LINAC) with nominal energy of 6 MV. To determine the surface dose, the total scatter factors (TSF) of three different field sizes were measured in a water phantom at 5 cm depth. Energy dependence of EBT3 was studied at three different depths, using a solid water phantom. The surface measurements were done with the RF for the same field sizes of the TSF measurements. The value of the percentage depth dose was calculated normalizing the doses measured in the RF with the LINAC output, at 5 cm depth, and the TSF.ResultsThe radiochromic films showed almost energy independence, the differences between the curves are 1.7% and 1.8% for the 1.5 cm and 10 cm depth, respectively. The percentage depth doses values at the surface measured for the 10 cm × 10 cm, 5 cm × 5 cm and 1 cm × 1 cm were 26.1 ± 1.3%, 21.3 ± 2.4% and 20.2 ± 2.6%, respectively.ConclusionsThe RF-EBT3 seems to be a detector suitable for measurements of the dose at the surface. This suggests that RF-EBT3 films might be good candidates as detectors for in vivo dosimetry.  相似文献   

8.
9.
A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.  相似文献   

10.
There are various different detectors, which can be used for radiotherapy measurements, and more are about to be adopted. Hybrid pixel detectors (HPD) have been originally developed for the high energy physics. However, over the last few years they also expanded in the medical physics. Novel 2D detector Pantherpix is a HPD designed specifically for the radiotherapy. In this article, its properties are characterised and an assessment of its use in radiotherapy photon beams is provided. Properties such as response stability, response linearity, angular dependence and energy dependence were studied. In order to prove sufficient clinical quality for relative dosimetry, further measurements were undertaken (i.e. dose profiles and collimator scatter factors). Acquired results were compared with ion chamber and gafchromic film results. Namely the applicability of PhPix for cobalt beam therapy, which is still widely used (and will be used in near future) in economically less developed countries, is considered.  相似文献   

11.
PurposeIn this work, the potential of an innovative “edgeless” silicon diode was evaluated as a response to the still unmet need of a reliable tool for plan dosimetry verification of very high dose, non-coplanar, patient-specific radiosurgery treatments. In order to prove the effectiveness of the proposed technology, we focused on radiosurgical treatments for functional disease like tremor or pain.MethodsThe edgeless diodes response has been validated with respect to clinical practice standard detectors by reproducing the reference dosimetry data adopted for the Treatment Planning System. In order to evaluate the potential for radiosurgery patient-specific treatment plan verification, the anthropomorphic phantom Alderson RANDO has been adopted along with three edgeless sensors, one placed in the centre of the Planning Target Volume, one superiorly and one inferiorly.ResultsThe reference dosimetry data obtained from the edgeless detectors are within 2.6% for output factor, off-axis ratio and well within 2% for tissue phantom ratio when compared to PTW 60,018 diode. The edgeless detectors measure a dose discrepancy of approximately 3.6% from the mean value calculated by the TPS. Larger discrepancies are obtained in very steep gradient dose regions when the sensors are placed outside the PTV.ConclusionsThe angular independent edgeless diode is proposed as an innovative dosimeter for patient quality assurance of brain functional disorders and other radiosurgery treatments. The comparison of the diode measurements with TPS calculations confirms that edgeless diodes are suitable candidates for patient-specific dosimetric verification in very high dose ranges delivered by non-isocentric stereotactic radiosurgery modalities.  相似文献   

12.
A discussion of different methods to evaluate dose/response and biological effects of ionizing radiation is given. Confocal scanning laser microscopy (CSLM) is presented as a high performing observation method for evaluating different cytological effects. Standard cytochemical techniques can be used to analyse the cell in situ with minimal disturbance of morphology and structure. If a relatively small number of cells are affected by the treatment, the use of confocal microscope observations is fast and has a better resolution than conventional fluorescence microscopy. The optical sectioning capability of the CSLM makes it possible to analyse stacks of cells on detectors up to a depth of 200 micrometer with a resolution of 0.7 micrometer. This is used to analyse single cell electrophoresis results and nuclear track analysis in poly allyl diglycol carbonate (PADC). Consecutive analysis of cells cultivated on PADC, and analysis of nuclear tracks after chemical etched tracks in the PADC, will make it possible to correlate physical dose with direct cellular effects. This is a promising method for single cell analysis and the study of the effects of ionizing radiation at low particle flux density.  相似文献   

13.
Radiation assessment and protection in space is the first step in planning future missions to the Moon and Mars, where mission and number of space travelers will increase and the protection of the geomagnetic shielding against the cosmic radiation will be absent. In this framework, the shielding effectiveness of two flexible materials, Kevlar and Nextel, were tested, which are largely used in the construction of spacecrafts. Accelerator-based tests clearly demonstrated that Kevlar is an excellent shield for heavy ions, close to polyethylene, whereas Nextel shows poor shielding characteristics. Measurements on flight performed onboard of the International Space Station and of the Foton-M3 capsule have been carried out with special attention to the neutron component; shielded and unshielded detectors (thermoluminescence dosemeters, bubble detectors) were exposed to a real radiation environment to test the shielding properties of the materials under study. The results indicate no significant effects of shielding, suggesting that thin shields in low-Earth Orbit have little effect on absorbed dose.  相似文献   

14.
Conversion coefficients from measurable quantities such as air kerma free-in-air or personal dose equivalent to effective dose were determined by phantom experiments. Heterogenic anthropomorphic phantoms representing children of one and five years age, and a Rando phantom representing an adult were exposed in the open field contaminated by different levels of radiocesium in the upper soil layer, in a forest site and inside a wooden house. LiF thermoluminescent (TL) detectors were used inside the phantoms for the estimation of organ doses and effective dose. Personal dosimeters similar to those used in radiation protection for individual dose measurements were placed onto the phantom surface (chest area). The ratios of dose values in separate organs to air kerma free-in-air varied from 0.69 to 1.15 for the children phantoms, and from 0.55 to 0.94 for the adult phantom, respectively, when irradiated in the open field. Body size (weight) was found to be the most important factor influencing the values of the conversion coefficients. The differences observed can reach approximately 40% when comparing conversion factors from air kerma free-in-air to effective dose for adults and newborns. For conversion coefficients from personal dose to effective dose, these differences can reach approximately 15%. The dependences of the various conversion coefficients on body mass were quantified by regression analysis. The results were compared with those calculated for a plane mono-energetic photon source having an energy of 700 keV and being located in the ground at a depth of 0.5 g cm−2. Calculated and measured conversion coefficients from air kerma free-in-air to effective dose agreed within 12%.  相似文献   

15.
The multileaf collimator (MLC) is the standard device used to shape radiation beams for 3-d conformal and intensity-modulated radiation therapy (IMRT). Due to the inherent properties of MLC, there is a small amount of radiation transmitted through the leaves, called radiation transmission (RT). Accurate measurements of this radiation are required to commission and validate IMRT-capable treatment planning systems because this radiation may impact the dosimetry of IMRT-calculated dose distributions. This work compares several detectors in the measurement of RT for a micro-multileaf collimation system. The results show that there are statistically significant differences in the measured RT values between detectors from 3.5 to 12.5% for the same MLC model and less than 0.2% relative to the isocentre dose for an open reference field. However, although small in magnitude, these differences may impact the dosimetry of IMRT treatment planning by up to 1.78 Gy to the healthy tissue surrounding the target for a treatment of 60 Gy in 30 fractions. By the later, these differences must be included as a source of uncertainty in IMRT dose delivery. Also, it must be established which detector offers the most reliable results in the measurement of the RT by using Monte Carlo simulation methods.  相似文献   

16.
In the planning of a new cyclotron facility, an accurate knowledge of the radiation field around the accelerator is fundamental for the design of shielding, the protection of workers, the general public and the environment.Monte Carlo simulations can be very useful in this process, and their use is constantly increasing. However, few data have been published so far as regards the proper validation of Monte Carlo simulation against experimental measurements, particularly in the energy range of biomedical cyclotrons.In this work a detailed model of an existing installation of a GE PETtrace 16.5 MeV cyclotron was developed using FLUKA. An extensive measurement campaign of the neutron ambient dose equivalent H1(10) in marked positions around the cyclotron was conducted using a neutron rem-counter probe and CR39 neutron detectors. Data from a previous measurement campaign performed by our group using TLDs were also re-evaluated.The FLUKA model was then validated by comparing the results of high-statistics simulations with experimental data. In 10 out of 12 measurement locations, FLUKA simulations were in agreement within uncertainties with all the three different sets of experimental data; in the remaining 2 positions, the agreement was with 2/3 of the measurements.Our work allows to quantitatively validate our FLUKA simulation setup and confirms that Monte Carlo technique can produce accurate results in the energy range of biomedical cyclotrons.  相似文献   

17.
BackgroundThe calculation and measurement on the surface of the skin presents a significant dosimetric problem because of numerous factors which have an influence on the dose distribution in this region.AimThe overall aim of this study was to check the agreement between doses measured with thermoluminescent detectors (TLD) during tomotherapy photon beam irradiation of the skin area of a solid water cylindrical phantom with doses calculated with Hi-Art treatment planning system (TPS).Material and MethodThe measurements of the dose were made with the use of a solid water cylindrical phantom - Cheese Phantom. Two bolus phantoms were used: 5 mm and 10 mm Six different planning treatments were generated. The doses were measured using TL detectors.ResultsIn the case of a tumor located near the surface of the skin, the mean dose for 0.5 cm bolus was - 1.94 Gy, and for 1 cm bolus - 2.03 Gy. For the tumor located inside the phantom and organ at risk on the same side that TL detectors, for a 0.5 cm bolus, mean dose was 0.658 Gy, and for a 1 cm bolus, 0.62 Gy.ConclusionThe analysis of results showed that the relative percentage difference between measured and planned dose in the field of irradiation was less than 10%, while the largest differences were on the board of the field of radiation and outside of the field of irradiation, where the dose was 0.08 Gy to 1 Gy.  相似文献   

18.
PurposePoint detectors are frequently used to measure patient's maximum skin dose (MSD) in fluoroscopically-guided interventional procedures (IP). However, their performance and ability to detect the actual MSD are rarely evaluated. The present study investigates the sampling uncertainty associated with the use of grids of point detectors to measure MSD in IP.MethodChemoembolisation of the liver (CE), percutaneous coronary intervention (PCI) and neuroembolisation (NE) procedures were studied. Spatial dose distributions were measured with XR-RV3 Gafchromic® films for 176 procedures. These distributions were used to simulate measurements performed using grids of detectors such as thermoluminescence detectors, with detector spacing from 1.4 up to 10 cm.ResultsThe sampling uncertainty was the highest in PCI and NE procedures. With 40 detectors covering the film area (36 cm × 44 cm), the maximum dose would be on average 86% and 63% of the MSD measured with Gafchromic® films in CE and PCI procedures, respectively. In NE procedures, with 27 detectors covering the film area (14 cm × 35 cm), the maximum dose measured would be on average 82% of the MSD obtained with the Gafchromic® films.ConclusionThermoluminescence detectors show good energy and dose response in clinical beam qualities. However the poor spatial resolution of such point-like dosimeters may far outweigh their good dosimetric properties. The uncertainty from the sampling procedure should be estimated when point detectors are used in IP because it may lead to strong underestimation of the MSD.  相似文献   

19.
PurposeIndividual dosimetry is undoubtedly one of the best methods of assessing the exposure of personnel to ionizing radiation, however in case of nuclear medicine, the method applied to measure the dose does not always present a picture of the worker’s actual exposure. The highly non-homogeneous dose distribution on the hand means that the ring dosimeter, routinely used to measure the Hp(0.07), provides only approximate dose values received by fingertips, the body part most exposed to ionizing radiation. This paper is an attempt to answer the question whether the wrist dosimeter used as a replacement for the ring dosimeter is able to provide information on doses for the most exposed fragments of the hand of an employee during handling procedures with the use of radiopharmaceuticals.MaterialsThroughout measurements performed in five nuclear medicine facilities, high-sensitivity thermoluminescent detectors were used.ResultsCorrection coefficients have been determined, which constitute an amendment to be made to move from the dose recorded by the wrist dosimeter to the doses received by the most exposed hand fragments. The fingertips received on average 25 times higher doses, compared to the values recorded by the wrist dosimeter.ConclusionsA wrist dosimeter can be used to measure the Hp(0.07) in nuclear medicine, including as a gauge of the most exposed parts of the hand – the fingertips. However, the applicability of correction coefficients makes it necessary to ensure a stable position of the wrist dosimeter during routine procedures.  相似文献   

20.
LET spectra of cosmic-ray nuclei for near earth orbits   总被引:1,自引:0,他引:1  
Measurements of cosmic-ray LET spectra were part of the radiobiological space research programs during the Spacelab 1 (SL-1) and the D1 missions. We analyzed CR-39 plastic nuclear track detectors of the Advanced Biostack experiment of SL-1 and of the Dosimetric Mapping and Carausius morosus experiments in the BIORACK on D1. The particle tracks in the CR-39 were detected and measured by an automatic scanning and measuring system. An in-flight calibration was derived from track measurements of minimum ionizing oxygen and iron nuclei and of stopping nuclei as a function of the residual range. LET spectra measured at different locations in the space shuttle are presented and discussed for both missions. A model describing the effects of the geomagnetic field of the earth on charged cosmic-ray particles and the shielding by matter is used to calculate LET spectra for the two missions and for typical space station orbits at low inclinations. A comparison of measured LET spectra and LET spectra calculated for different flight parameters shows that besides geomagnetic shielding the shielding by matter is most important in comparison to solar modulation and to variation of particle flux with flight altitude. Model calculations must be improved and must consider more detailed sectored shielding by matter and the influence of trapped radiation. The last item is of importance in the case of low-inclination orbits.  相似文献   