首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Diagnosis followed by effective treatment of tuberculosis (TB) reduces transmission and saves lives in persons living with HIV (PLHIV). Sputum smear microscopy is widely used for diagnosis, despite limited sensitivity in PLHIV. Evidence is needed to determine the optimal diagnostic approach for these patients.

Methods

From May 2011 through June 2012, we recruited PLHIV from 15 HIV treatment centers in western Kenya. We collected up to three sputum specimens for Ziehl-Neelsen (ZN) and fluorescence microscopy (FM), GeneXpert MTB/RIF (Xpert), and culture, regardless of symptoms. We calculated the incremental yield of each test, stratifying results by CD4 cell count and specimen type; data were analyzed to account for complex sampling.

Results

From 778 enrolled patients, we identified 88 (11.3%) laboratory-confirmed TB cases. Of the 74 cases who submitted 2 specimens for microscopy and Xpert testing, ZN microscopy identified 25 (33.6%); Xpert identified those plus an additional 18 (incremental yield = 24.4%). Xpert testing of spot specimens identified 48 (57.0%) of 84 cases; whereas Xpert testing of morning specimens identified 50 (66.0%) of 76 cases. Two Xpert tests detected 22/24 (92.0%) TB cases with CD4 counts <100 cells/μL and 30/45 (67.0%) of cases with CD4 counts ≥100 cells/μl.

Conclusions

In PLHIV, Xpert substantially increased diagnostic yield compared to smear microscopy and had the highest yield when used to test morning specimens and specimens from PLHIV with CD4 count <100 cells/μL. TB programs unable to replace smear microscopy with Xpert for all symptomatic PLHIV should consider targeted replacement and using morning specimens.  相似文献   

2.

Background

Detection of the mycobacterial cell wall antigen lipoarabinomannan (LAM) in urine can be used to diagnose HIV-associated tuberculosis (TB) using a qualitative (positive/negative) read-out. However, it is not known whether the quantity of LAM present in urine provides additional prognostic information.

Methods/Findings

Consecutively recruited adult outpatients initiating antiretroviral therapy (ART) in South Africa were investigated for TB regardless of clinical symptoms using sputum smear microscopy and liquid culture (reference standard). Urine samples were tested using the Clearview TB-ELISA for LAM and the Xpert MTB/RIF assay. The ELISA optical densities (OD) were used as a quantitative assessment of urine LAM. Among 514 patients with complete sputum and urine LAM OD results, culture-confirmed TB was diagnosed in 84 patients. Twenty-three (27.3%) were LAM-positive with a median LAM OD of 0.68 (IQR 0.16–2.43; range, 0.10–3.29) and 61 (72.6%) were LAM negative (LAM OD <0.1 above background). Higher LAM ODs were associated with a range of prognostic indices, including lower CD4 cell counts, lower haemoglobin levels, higher blood neutrophil counts and higher mycobacterial load as assessed using both sputum and urine samples. The median LAM OD among patients who died was more than 6.8-fold higher than that of patients who remained alive at 3 months (P<0.001). The small number of deaths, however, precluded adequate assessment of mortality risk stratified according to urine LAM OD.

Conclusions

In patients with HIV-associated TB, concentrations of LAM in urine were strongly associated with a range of poor prognostic characteristics known to be associated with mortality risk. Urine LAM assays with a semi-quantitative (negative vs. low-positive vs. high-positive) read-out may have improved clinical utility over assays with a simple binary result.  相似文献   

3.

Background

Undiagnosed and misdiagnosed tuberculosis (TB) drives the epidemic in India. Serological (antibody detection) TB tests are not recommended by any agency, but widely used in many countries, including the Indian private sector. The cost and impact of using serology compared with other diagnostic techniques is unknown.

Methods and Findings

Taking a patient cohort conservatively equal to the annual number of serological tests done in India (1.5 million adults suspected of having active TB), we used decision analysis to estimate costs and effectiveness of sputum smear microscopy (US$3.62 for two smears), microscopy plus automated liquid culture (mycobacterium growth indicator tube [MGIT], US$20/test), and serological testing (anda-tb ELISA, US$20/test). Data on test accuracy and costs were obtained from published literature. We adopted the perspective of the Indian TB control sector and an analysis frame of 1 year. Our primary outcome was the incremental cost per disability-adjusted life year (DALY) averted. We performed one-way sensitivity analysis on all model parameters, with multiway sensitivity analysis on variables to which the model was most sensitive.If used instead of sputum microscopy, serology generated an estimated 14,000 more TB diagnoses, but also 121,000 more false-positive diagnoses, 102,000 fewer DALYs averted, and 32,000 more secondary TB cases than microscopy, at approximately four times the incremental cost (US$47.5 million versus US$11.9 million). When added to high-quality sputum smears, MGIT culture was estimated to avert 130,000 incremental DALYs at an incremental cost of US$213 per DALY averted. Serology was dominated by (i.e., more costly and less effective than) MGIT culture and remained less economically favorable than sputum smear or TB culture in one-way and multiway sensitivity analyses.

Conclusions

In India, sputum smear microscopy remains the most cost-effective diagnostic test available for active TB; efforts to increase access to quality-assured microscopy should take priority. In areas where high-quality microscopy exists and resources are sufficient, MGIT culture is more cost-effective than serology as an additional diagnostic test for TB. These data informed a recently published World Health Organization policy statement against serological tests. Please see later in the article for the Editors'' Summary  相似文献   

4.

Background

Low income, high-tuberculosis burden, countries are considering selective deployment of Xpert MTB/RIF assay (Xpert) due to high cost per test. We compared the diagnostic gain of the Xpert add-on strategy with Xpert replacement strategy for pulmonary tuberculosis diagnosis among HIV-infected adults to inform its implementation.

Methods

The first diagnostic sputum sample of 424 HIV-infected adults (67% with CD4 counts ≤200/mm3) suspected for tuberculosis was tested by direct Ziehl-Neelsen (DZN) and direct fluorescent microscopy (DFM); concentrated fluorescent microscopy (CFM); Lowenstein-Jensen (LJ) and Mycobacterial Growth Indicator Tube (MGIT) culture; and Xpert. Overall diagnostic yield and sensitivity were calculated using MGIT as reference comparator. The sensitivity of Xpert in an add-on strategy was calculated as the number of smear negative but Xpert positive participants among MGIT positive participants.

Results

A total of 123 (29.0%) participants were MGIT culture positive for Mycobacterium tuberculosis. The sensitivity (95% confidence interval) was 31.7% (23.6–40.7%) for DZN, 35.0% (26.5–44.0%) for DFM, 43.9% (34.9–53.1%) for CFM, 76.4% (67.9–83.6) for Xpert and 81.3% (73.2–87.7%) for LJ culture. Add-on strategy Xpert showed an incremental sensitivity of 44.7% (35.7–53.9%) when added to DZN, 42.3% (33.4–51.5%) to DFM and 35.0% (26.5–44.0%) to CFM. This translated to an overall sensitivity of 76.4%, 77.3% and 79.0% for add-on strategies based on DZN, DFM and CFM, respectively, compared to 76.4% for Xpert done independently. From replacement to add-on strategy, the number of Xpert cartridges needed was reduced by approximately 10%.

Conclusions

Among HIV-infected TB suspects, doing smear microscopy prior to Xpert assay in add-on fashion only identifies a few additional TB cases.  相似文献   

5.

Background

Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients.

Methodology/Principal Findings

281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity).

Conclusions/Significance

This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity.  相似文献   

6.

Background

The World Health Organization has endorsed the Xpert MTB/RIF assay for investigation of patients suspected of having tuberculosis (TB). However, its utility for routine TB screening and detection of rifampicin resistance among HIV-infected patients with advanced immunodeficiency enrolling in antiretroviral therapy (ART) services is unknown.

Methods and Findings

Consecutive adult HIV-infected patients with no current TB diagnosis enrolling in an ART clinic in a South African township were recruited regardless of symptoms. They were clinically characterised and invited to provide two sputum samples at a single visit. The accuracy of the Xpert MTB/RIF assay for diagnosing TB and drug resistance was assessed in comparison with other tests, including fluorescence smear microscopy and automated liquid culture (gold standard) and drug susceptibility testing. Of 515 patients enrolled, 468 patients (median CD4 cell count, 171 cells/µl; interquartile range, 102–236) produced at least one sputum sample, yielding complete sets of results from 839 samples. Mycobacterium tuberculosis was cultured from 81 patients (TB prevalence, 17.3%). The overall sensitivity of the Xpert MTB/RIF assay for culture-positive TB was 73.3% (specificity, 99.2%) compared to 28.0% (specificity, 100%) using smear microscopy. All smear-positive, culture-positive disease was detected by Xpert MTB/RIF from a single sample (sensitivity, 100%), whereas the sensitivity for smear-negative, culture-positive TB was 43.4% from one sputum sample and 62.3% from two samples. Xpert correctly identified rifampicin resistance in all four cases of multidrug-resistant TB but incorrectly identified resistance in three other patients whose disease was confirmed to be drug sensitive by gene sequencing (specificity, 94.1%; positive predictive value, 57%).

Conclusions

In this population of individuals at high risk of TB, intensive screening using the Xpert MTB/RIF assay increased case detection by 45% compared with smear microscopy, strongly supporting replacement of microscopy for this indication. However, despite the ability of the assay to rapidly detect rifampicin-resistant disease, the specificity for drug-resistant TB was sub-optimal. Please see later in the article for the Editors'' Summary  相似文献   

7.

Background

Respiratory isolation of inpatients during evaluation for TB is a slow and costly process in low-burden settings. Xpert MTB/RIF (Xpert) is a novel molecular test for tuberculosis (TB) that is faster and more sensitive but substantially more expensive than smear microscopy. No previous studies have examined the costs of molecular testing as a replacement for smear microscopy in this setting.

Methods

We conducted an incremental cost–benefit analysis comparing the use of a single negative Xpert versus two negative sputum smears to release consecutive adult inpatients with presumed TB from respiratory isolation at an urban public hospital in the United States. We estimated all health-system costs and patient outcomes related to Xpert implementation, diagnostic evaluation, isolation, hospitalization, and treatment. We performed sensitivity and probabilistic uncertainty analyses to determine at what threshold the Xpert strategy would become cost-saving.

Results

Among a hypothetical cohort of 234 individuals undergoing evaluation for presumed active TB annually, 6.4% had culture-positive TB. Compared to smear microscopy, Xpert reduced isolation bed utilization from an average of 2.7 to 1.4 days per patient, leading to a 48% reduction in total annual isolation bed usage from 632 to 328 bed-days. Xpert saved an average of $2,278 (95% uncertainty range $1582–4570) per admission, or $533,520 per year, compared with smear microscopy.

Conclusions

Molecular testing for TB could provide substantial savings to hospitals in high-income countries by reducing respiratory isolation usage and overall length of stay.  相似文献   

8.
George G  Mony P  Kenneth J 《PloS one》2011,6(6):e21007

Background

Despite the advent of novel diagnostic techniques, smear microscopy remains as the most practical test available in resource-limited settings for tuberculosis (TB) diagnosis. Due to the low sensitivity of microscopy and the long time required for culture, feasible and accessible rapid diagnostic methods are urgently needed. Loop-mediated Isothermal Amplification (LAMP) is a promising nucleic-acid amplification assay, which could be accessible, cost-effective and more suited for use with unpurified samples.

Methodology/Principal Findings

In the current study, the objective was to assess the efficacy of a LAMP assay for tuberculosis compared with fluorescence smear microscopy as well as Löwenstein-Jensen (LJ) and Mycobacteria Growth Indicator Tube (MGIT) cultures for the diagnosis of pulmonary tuberculosis using sputum samples. Smear microscopy and culture were performed for decontaminated and concentrated sputum from TB suspects and the LAMP was also performed on these specimens. The LAMP and smear microscopy were compared, in series and in parallel, to culture. LAMP and smear microscopy showed sensitivities of 79.5% and 82.1% respectively and specificities of 93.8% and 96.9% respectively, compared to culture. LAMP and smear in series had sensitivity and specificity of 79.5% and 100.0% respectively. LAMP and smear in parallel had sensitivity and specificity of 82.1% and 90.6% respectively.

Conclusions/Significance

The overall efficacies of LAMP and fluorescence smear microscopy in the current study were high and broadly similar. LAMP and smear in series had high specificity (100.0%) and can be used as a rule-in test combination. However, the performance of LAMP in smear negative samples was found to be insufficient.  相似文献   

9.
CD4+/CD8+ T cells play a major role in conferring immune protection against tuberculosis (TB), but it remains unknown how the immune responses of CD4+/CD8+ T cells exactly correlate with the clinical variables and disease statuses during anti-TB chemotherapy. To address this, several major immune parameters of CD4+/CD8+ T cells in peripheral blood derived from pulmonary TB patients and healthy volunteers were evaluated. We observed that active TB infection induced lower CD3+ T cell and CD4+ T cell levels but higher CD8+T cell levels, while anti-TB chemotherapy reversed these effects. Also, anti-TB treatment induced enhanced production of IL-2 and IFN-γ but reduced expression of IL-10 and IL-6. Moreover, the dynamic changes of CD3, CD4, and CD8 levels did not show a significant association with sputum smear positivity. However, the frequencies of IL-2+CD4+ or IL-10 + CD4+ T effector subpopulation or IL-1β production in peripheral blood showed significant difference between patients positive for sputum smear and patients negative for sputum smear after anti-TB treatment. These findings implicated that recovery of Th1/CD8+T cell effector levels might be critical immunological events in pulmonary TB patients after treatment and further suggested the importance of these immunological parameters as potential biomarkers for prediction of TB progress and prognosis.  相似文献   

10.
Ethiopia adopted Public-Private Mix Directly Observed Treatment Short Course Chemotherapy (PPM-DOTS) strategy for tuberculosis (TB) control program. Quality of sputum smear microscopy has paramount importance for tuberculosis control program in resource-poor countries like Ethiopia. A cross-sectional study was conducted to assess the quality of sputum smear microscopy in 37 Public-Private Mix laboratories in West Amhara, Ethiopia. The three external quality assessment methods (onsite evaluation, panel testing and blind rechecking) were employed. Onsite assessment revealed that 67.6% of PPM-DOTS laboratories were below the standard physical space (5 X 6) m2. The average monthly workload per laboratory technician was 19.5 (SD±2.9) slides with 12.8% positivity rate. The quality of Acid Fast Bacilli (AFB) staining reagents was sub-standard. The overall agreement for blind rechecking of 1,123 AFB slides was 99.4% (Kappa = 0.97). Reading of 370 AFB panel slides showed 3.5% false reading (Kappa = 0.92). Moreover, the consistency of reading scanty bacilli slides was lower (93%) compared to 1+, 2+ and 3+ bacilli. Based on blind rechecking and panel testing results, PPM-DOTS site laboratories showed good agreement with the reference laboratory. Physical space and qualities of AFB reagents would be areas of intervention to sustain the quality of sputum smear microscopy. Therefore, regular external quality assessment and provision of basic laboratory supplies for TB diagnosis would be the way forward to improve the quality of sputum smear microscopy services in PPM-DOTS laboratories.  相似文献   

11.

Background

Each follow-up during the course of tuberculosis treatment currently requires two sputum examinations. However, the incremental yield of the second sputum sample during follow-up of different types of tuberculosis patients has never been determined precisely.

Objectives

To assess the incremental yield of the second sputum sample in the follow-up of tuberculosis patients under the Revised National Tuberculosis Control Programme (RNTCP) in Chhattisgarh, India.

Methodology

A record review of tuberculosis (TB) patients registered in 2009 using a structured proforma from two sources, Tuberculosis and Laboratory Register, was undertaken in the six districts of Chhattisgarh, India.

Results

In smear positive cases, of 10,048 follow-up examinations, 45 (0.5%) were found to be smear positive only on the second sputum when the result of the first sample was negative. In smear negative pulmonary and extra pulmonary TB patients, of 6,206 follow-up smear examinations, 11(0.2%) were found to be smear positive.

Conclusions

The incremental yield of a second smear examination was very low, indicating that examination of one sputum sample is enough during follow-up among TB patients. There is insufficient yield to support sputum smear microscopy for monitoring smear negative pulmonary TB and extra pulmonary TB patients. These results indicate that the follow-up smear microscopy can be substantially simplified with favourable resource implications.  相似文献   

12.

Background

Direct sputum smear microscopy for tuberculosis (TB) lacks sensitivity for the detection of acid fast bacilli. Sputum pretreatment procedures may enhance sensitivity. We did a pilot study to compare the diagnostic accuracy and incremental yield of two short-duration (<1 hour) sputum pretreatment procedures to optimize direct smears among patients with suspected TB at a referral hospital in India.

Methodology/Findings

Blinded laboratory comparison of bleach and universal sediment processing (USP) pretreated centrifuged auramine smears to direct Ziehl-Neelsen (ZN) and direct auramine smears and to solid (Loweinstein-Jensen (LJ)) and liquid (BACTEC 460) culture. 178 pulmonary and extrapulmonary TB suspects were prospectively recruited during a one year period. Thirty six (20.2%) were positive by either solid or liquid culture. Direct ZN smear detected 22 of 36 cases and direct auramine smears detected 26 of 36 cases. Bleach and USP centrifugation detected 24 cases each, providing no incremental yield beyond direct smears. When compared to combined culture, pretreated smears were not more sensitive than direct smears (66.6% vs 61.1 (ZN) or 72.2 (auramine)), and were not more specific (92.3% vs 93.0 (ZN) or 97.2 (auramine).

Conclusions/Significance

Short duration sputum pretreatment with bleach and USP centrifugation did not increase yield as compared to direct sputum smears. Further work is needed to confirm this in a larger study and also determine if longer duration pre-treatment might be effective in optimizing smear microscopy for TB.  相似文献   

13.

Background

Fluorescence microscopy (FM) has not been implemented widely in TB endemic settings and little evaluation has been done in HIV-infected patients. We evaluated diagnostic performance, time and costs of FM with light-emitting diodes technology (LED-FM), compared with conventional (Zieh-Neelsen) microscopy in a hospital in Indonesia which acts as referral centre for HIV-infected patients.

Method

We included pulmonary tuberculosis suspects from the outpatient and HIV clinic. Direct and concentrated sputum smears were examined using LED-FM and ZN microscopy by two technicians who were blinded for the HIV-status and the result of the comparative test. Mean reading time per slide was recorded and cost of each slide was calculated. Mycobacteria culture served as the reference standard.

Results

Among 404 tuberculosis suspects from the outpatient clinic and 256 from the HIV clinic, mycobacteria culture was positive in 12.6% and 27%, respectively. The optimal sensitivity of LED-FM was achieved by using a threshold of ≥2 AFB/length. LED-FM had a higher sensitivity (75.5% vs. 54.9%, P<0.01) but lower specificity (90.0% vs 96.6%, P<0.01) compared to ZN microscopy. HIV was associated with a lower sensitivity but similar specificity. The average reading time using LED-FM was significantly shorter (2.23±0.78 vs 5.82±1.60 minutes, P<0.01), while costs per slide were similar.

Conclusion

High sensitivity of LED-FM combined with shorter reading time of sputum smear slides make this method a potential alternative to ZN microscopy. Additional data on specificity are needed for effective implementation of this technique in high burden TB laboratories.  相似文献   

14.

Background

Numerous patient and healthcare system-related delays contribute to the overall delay experienced by patients from onset of TB symptoms to diagnosis and treatment. Such delays are critical as infected individuals remain untreated in the community, providing more opportunities for transmission of the disease and adversely affecting the epidemic.

Methodology/Principal Findings

We present an analysis of the factors that contribute to the overall delay in TB diagnosis and treatment, in a resource-poor setting. Impact on the distribution of diagnostic delay times was assessed for various factors, the sensitivity of the diagnostic method being found to be the most significant. A linear relationship was found between the sensitivity of the test and the predicted mean delay time, with an increase in test sensitivity resulting in a reduced mean delay time and a reduction in the drop-out rate.

Conclusions/Significance

The results show that in a developing country a number of delay factors, particularly the low sensitivity of the initial sputum smear microscopy test, potentially increase total diagnostic delay times experienced by TB patients significantly. The results reinforce the urgent need for novel diagnostic methods, both for smear positive and negative TB, that are highly sensitive, accessible and point of care, in order to reduce mean delay times.  相似文献   

15.

Background

Xpert MTB/RIF (“Xpert”) is a molecular test for detection of Mycobacterium tuberculosis (MTB) in sputum. Performance characteristics have been established for its use during passive tuberculosis (TB) case detection in symptomatic TB suspects, but Xpert performance has not been assessed in other settings. Objectives were to determine Xpert performance and costs in the context of a TB prevalence survey.

Methodology/Principal Findings

This was a diagnostic sub-study of a TB prevalence survey conducted in gold mining companies in South Africa. Sputa (one per participant) were tested using smear microscopy, liquid culture (reference comparator), and Xpert. Costs were collected using an ingredients approach and analyzed using a public health program perspective. 6893 participants provided a sputum specimen. 187/6893 (2.7%) were positive for MTB in culture, 144/6893 (2.1%) were positive for MTB by Xpert, and 91/6893 (1.3%) were positive for acid fast bacilli by microsocopy. Sensitivity, specificity, positive predictive value, and negative predictive value for detection of MTB by Xpert were 62.6% (95% confidence interval [CI] 55.2, 69.5), 99.6% (99.4, 99.7), 81.3% (73.9, 87.3), and 98.9 (98.6, 98.8); agreement between Xpert and culture was 98.5% (98.2, 98.8). Sensitivity of microscopy was 17.6% (12.5, 23.9). When individuals with a history of TB treatment were excluded from the analysis, Xpert specificity was 99.8 (99.7, 99.9) and PPV was 90.6 (83.3, 95.4) for detection of MTB. For the testing scenario of 7000 specimens with 2.7% of specimens culture positive for MTB, costs were $165,690 for Xpert and $115,360 for the package of microscopy plus culture.

Conclusion

In the context of a TB prevalence survey, the Xpert diagnostic yield was substantially higher than that of microscopy yet lower than that of liquid culture. Xpert may be useful as a sole test for TB case detection in prevalence surveys, particularly in settings lacking capacity for liquid culture.  相似文献   

16.

Background

The Xpert MTB/RIF (Cepheid) non-laboratory-based molecular assay has potential to improve the diagnosis of tuberculosis (TB), especially in HIV-infected populations, through increased sensitivity, reduced turnaround time (2 h), and immediate identification of rifampicin (RIF) resistance. In a prospective clinical validation study we compared the performance of Xpert MTB/RIF, MTBDRplus (Hain Lifescience), LightCycler Mycobacterium Detection (LCTB) (Roche), with acid fast bacilli (AFB) smear microscopy and liquid culture on a single sputum specimen.

Methods and Findings

Consecutive adults with suspected TB attending a primary health care clinic in Johannesburg, South Africa, were prospectively enrolled and evaluated for TB according to the guidelines of the National TB Control Programme, including assessment for smear-negative TB by chest X-ray, clinical evaluation, and HIV testing. A single sputum sample underwent routine decontamination, AFB smear microscopy, liquid culture, and phenotypic drug susceptibility testing. Residual sample was batched for molecular testing. For the 311 participants, the HIV prevalence was 70% (n = 215), with 120 (38.5%) culture-positive TB cases. Compared to liquid culture, the sensitivities of all the test methodologies, determined with a limited and potentially underpowered sample size (n = 177), were 59% (47%–71%) for smear microscopy, 76% (64%–85%) for MTBDRplus, 76% (64%–85%) for LCTB, and 86% (76%–93%) for Xpert MTB/RIF, with specificities all >97%. Among HIV+ individuals, the sensitivity of the Xpert MTB/RIF test was 84% (69%–93%), while the other molecular tests had sensitivities reduced by 6%. TB detection among smear-negative, culture-positive samples was 28% (5/18) for MTBDRplus, 22% (4/18) for LCTB, and 61% (11/18) for Xpert MTB/RIF. A few (n = 5) RIF-resistant cases were detected using the phenotypic drug susceptibility testing methodology. Xpert MTB/RIF detected four of these five cases (fifth case not tested) and two additional phenotypically sensitive cases.

Conclusions

The Xpert MTB/RIF test has superior performance for rapid diagnosis of Mycobacterium tuberculosis over existing AFB smear microscopy and other molecular methodologies in an HIV- and TB-endemic region. Its place in the clinical diagnostic algorithm in national health programs needs exploration. Please see later in the article for the Editors'' Summary  相似文献   

17.
The present study analysed the concordance among four different molecular diagnostic methods for tuberculosis (TB) in pulmonary and blood samples from immunocompromised patients. A total of 165 blood and 194 sputum samples were collected from 181 human immunodeficiency virus (HIV)-infected patients with upper respiratory complaints, regardless of suspicious for TB. The samples were submitted for smear microscopy, culture and molecular tests: a laboratory-developed conventional polymerase chain reaction (PCR) and real-time quantitative PCR (qPCR) and the Gen-Probe and Detect-TB Ampligenix kits. The samples were handled blindly by all the technicians involved, from sample processing to results analysis. For sputum, the sensitivity and specificity were 100% and 96.7% for qPCR, 81.8% and 94.5% for Gen-Probe and 100% and 66.3% for Detect-TB, respectively. qPCR presented the best concordance with sputum culture [kappa (k) = 0.864)], followed by Gen-Probe (k = 0.682). For blood samples, qPCR showed 100% sensitivity and 92.3% specificity, with a substantial correlation with sputum culture (k = 0.754) and with the qPCR results obtained from sputum of the corresponding patient (k = 0.630). Conventional PCR demonstrated the worst results for sputa and blood, with a sensitivity of 100% vs. 88.9% and a specificity of 46.3% vs. 32%, respectively. Commercial or laboratory-developed molecular assays can overcome the difficulties in the diagnosis of TB in paucibacillary patients using conventional methods available in most laboratories.  相似文献   

18.
BackgroundThis study established evidence about the diagnostic performance of trained giant African pouched rats for detecting Mycobacterium tuberculosis in sputum of well-characterised patients with presumptive tuberculosis (TB) in a high-burden setting.MethodsThe TB detection rats were evaluated using sputum samples of patients with presumptive TB enrolled in two prospective cohort studies in Bagamoyo, Tanzania. The patients were characterised by sputum smear microscopy and culture, including subsequent antigen or molecular confirmation of Mycobacterium tuberculosis, and by clinical data at enrolment and for at least 5-months of follow-up to determine the reference standard. Seven trained giant African pouched rats were used for the detection of TB in the sputum samples after shipment to the APOPO project in Morogoro, Tanzania.ResultsOf 469 eligible patients, 109 (23.2%) were culture-positive for Mycobacterium tuberculosis and 128 (27.3%) were non-TB controls with sustained recovery after 5 months without anti-TB treatment. The HIV prevalence was 46%. The area under the receiver operating characteristic curve of the seven rats for the detection of culture-positive pulmonary tuberculosis was 0.72 (95% CI 0.66–0.78). An optimal threshold could be defined at ≥2 indications by rats in either sample with a corresponding sensitivity of 56.9% (95% CI 47.0–66.3), specificity of 80.5% (95% CI 72.5–86.9), positive and negative predictive value of 71.3% (95% CI 60.6–80.5) and 68.7% (95% CI 60.6–76.0), and an accuracy for TB diagnosis of 69.6%. The diagnostic performance was negatively influenced by low burden of bacilli, and independent of the HIV status.ConclusionGiant African pouched rats have potential for detection of tuberculosis in sputum samples. However, the diagnostic performance characteristics of TB detection rats do not currently meet the requirements for high-priority, rapid sputum-based TB diagnostics as defined by the World Health Organization.  相似文献   

19.

Background

Light-emitting diode fluorescence microscopy (LED-FM) has been shown to be more sensitive than conventional bright field microscopy using Ziehl-Neelsen (ZN) stain in detecting sputum smear positive tuberculosis in controlled laboratory conditions. In 2012, Auramine O staining based LED-FM replaced conventional ZN microscopy in 200 designated microscopy centres (DMC) of medical colleges operating in collaboration with India’s Revised National Tuberculosis Control Programme. We aimed to assess the impact of introduction of LED-FM services on sputum smear positive case detection under program conditions.

Methods

This was a before and after comparison study. In 15 randomly selected medical college DMCs, all presumptive TB patients who underwent sputum smear examination in the years 2011 (before LED-FM) and 2012 (after LED-FM) were compared. An additional 15 comparable DMCs that implemented conventional ZN sputum smear microscopy were also selected for comparison between 2011 and 2012.

Results

The proportion of presumptive TB patients (PTP)found sputum smear positive increased by 30%- from 13.6% (3432/25159) in 2011 to 17.8% (4706/26426) in 2012 (P value <0.01) in the sites that implemented LED-FM microscopy, whereas in DMCs where the ZN staining procedure is followed the proportion of sputum smear positive had remained unchanged (13.0%versus 12.6%;P value0.31).

Conclusion

Use of LED-FM significantly increased the proportion of smear positive cases among presumptive TB patients under routine program conditions in high workload laboratories. The study provides operational evidence needed to scale-up the use of LED-FM in similar settings in India and beyond.  相似文献   

20.

Background

Early and effective detection of Mycobacterium tuberculosis (MTB), particularly in smear-negative tuberculosis (TB), is a priority for global TB control. Loop-mediated isothermal amplification with a procedure for ultra rapid DNA extraction (PURE-LAMP) can detect TB in sputum samples rapidly and with high sensitivity and specificity. However, the PURE-LAMP test has not been effectively evaluated, especially in resource-limited laboratories. In this study, we evaluated the performance of the PURE-LAMP test for TB detection in TB suspects from two county-level TB dispensaries in China.

Methodology/Principal Findings

From April 2011 to February 2012, patients with suspected TB were continuously enrolled from two county-level TB laboratories in China. Three sputum samples (spot, night, and morning sputum) were collected from each recruited patient. Detection of MTB by PURE-LAMP was compared to a reference standard L-J culture. The results showed that the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection was 70.67%, while the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection in smear positive and culture positive patients and smear negative and culture positive patients was 92.12% and 53.81%, respectively. The specificity of PURE-LAMP based on spot sputum for MTB detection was 98.32%. The sensitivity and specificity of the PURE-LAMP test based on three sputa combination for MTB detection was 88.80% and 96.86%, respectively. The results also showed that the PURE-LAMP test had a significantly lower contamination rate than did solid culture.

Conclusions/Significance

The study suggested that, in peripheral-level TB laboratories in China, the PURE-LAMP test showed high sensitivity and specificity for TB detection in TB suspects, making it a more effective, rapid, and safe method worthy of broader use in the future.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号