首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new simple, accurate and sensitive sequential injection analysis chemiluminescence (CL) detection method for the determination of cefditoren pivoxil (CTP) has been developed. The developed method was based on the enhancement effect of silver nanoparticles on the CL signal arising from a luminol–potassium ferricyanide reaction in the presence of CTP. The optimum conditions relevant to the effect of luminol, potassium ferricyanide and silver nanoparticle concentrations were investigated. The proposed method showed linear relationships between relative CL intensity and the investigated drug concentration at the range 0.001–5000 ng/mL, (r = 0.9998, n = 12) with a detection limit of 0.5 pg/mL and quantification limit of 0.001 ng/mL. The relative standard deviation was 1.6%. The proposed method was employed for the determination of CTP in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. In addition, the interference of some related cephalosporins was tested. No interference was recorded. The obtained sequential injection analysis‐CL results were statistically compared with those from a reported method and did not show any significant differences. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
《Luminescence》2002,17(3):165-167
A new flow injection chemiluminescence method is described for the determination of captopril. It is based on the enhancing effect of captopril on the chemiluminescence reaction of luminol with potassium ferricyanide in alkaline solution in the presence of potassium ferrocyanide. The method allows the determination of captopril over 0.1–40 µg/mL range, with a relative standard deviation (SD) of 1.0% for the determination of 0.5 µg/mL captopril solution in 11 repeated measurements. The method was satisfactorily applied to the determination of captopril in commercial captopril tablets. The possible reaction mechanism is also discussed briefly. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

3.
A post‐chemiluminescence (PCL) phenomenon was observed when chloramphenicol was injected into a mixture of luminol and potassium periodate after the chemiluminescence (CL) reaction of luminol–potassium periodate had finished. The possible reaction mechanism was proposed based on studies of the CL kinetic characteristics, the CL spectra, the fluorescence spectra and the UV‐vis absorption spectra of the related substances. Based on the PCL reaction, a rapid and sensitive method for the determination of chloramphenicol was established. The linear response range was 6.0 × 10?7–1.0 × 10?5 mol/L, with a correlation coefficient of 0.9986. The relative standard deviation (RSD) for 5.0 × 10?6 mol/L chloramphenicol was 2.3% (n = 11). The detection limit was 1.6 × 10?7 mol/L. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
2-Naphthyl acetate acts as a pro-enhancer of the luminol–H2O2–horseradish peroxidase reaction. Cholinesterase hydrolyses the bound acetyl group and produces 2-naphthol, and this compound is an enhancer of the chemiluminescent reaction. We studied the kinetics of chemiluminescent emission and the influence of 2-naphthyl acetate and cholinesterase enzyme concentration. The cholinesterase concentration versus chemiluminescence intensity maximum was linear for cholinesterase between 0 and 181 μU/mL, with a detection limit of 8 μU/mL and a relative standard deviation of 9.5% (n = 3), for a sample containing 90.67 μU/mL of cholinesterase.  相似文献   

5.
The chemiluminescence of the luminol–H2O2–horseradish peroxidase system is increased by fluorescein. Fluorescein produces an enhancement of the luminol chemiluminescence similar to that of phenolphthalein, by an energy transfer process from luminol to fluorescein. The maximum intesity and the total chemiluminescence emission (between 380 and 580 nm) of luminol with fluorescein was more than three times greater than without fluorescein; however, the emission duration was shorter. The emission spectra in the presence of fluorescein had two maxima (425 and 535 nm) and the enhancement was dependent on pH and fluorescein concentration. A mechanism is proposed to explain these effects. © 1997 John Wiley & Sons, Ltd.  相似文献   

6.
The oxidation reaction of luminol with AgNO3 can produce chemiluminescence (CL) in the presence of silver nanoparticles (NPs) in alkaline solution. Based on the studies of UV‐vis absorption spectra, photoluminescence (PL) spectra and CL spectra, a CL enhancement mechanism is proposed. The CL emission spectrum of the luminol–AgNO3–Ag NPs system indicated that the luminophore was still 3‐aminophthalate. On injection of silver nanoparticles into the mixture of luminol and AgNO3, they catalysed the reduction of AgNO3 by luminol. The product luminol radicals reacted with the dissolved oxygen, to produce a strong CL emission. As a result, the CL intensity was substantially increased. Moreover, the influences of 18 amino acids, e.g. cystine, tyrosine and asparagine, and 25 organic compounds, including gallic acid, tannic acid and hydroquinone, on the luminol–AgNO3–Ag NPs CL system were studied by a flow‐injection procedure, which led to an effective method for detecting these compounds. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
《Luminescence》2003,18(1):42-48
Oscillating chemical reactions are complex systems involving a large number of chemical species. In oscillating chemical reactions some species, usually reaction intermediates, exhibit fluctuation in concentration. Visible oscillating chemiluminescence, produced by the addition of luminol (3‐aminophthalhydrazide) to the oscillating system H2O2–KSCN–CuSO4–NaOH, was investigated. In this study the effect of varying the concentration of H2O2, KSCN, CuSO4, NaOH and luminol was investigated in a batch reactor. We showed that the concentration of all components involved in the oscillating chemilumenscent reaction influenced the light intensity and the oscillation period. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

8.
The chemiluminescence (CL) behaviour of the luminol–potassium periodate system enhanced by CdTe quantum dots capped with thioglycolic acid (TGA–CdTe QDs) was studied using kinetic experiments, CL spectra, UV–vis absorption spectra and fluorescence spectra. The production of oxygen‐containing reactant intermediates (O2?? and OH?) in the present CL system was verified by CL. The possible CL mechanism was discussed in detail. Furthermore, theophylline (THP) was determined based on its enhancement of the CL intensity of the CdTe QDs–luminol–potassium periodate system coupled with a flow‐injection technique. Under these optimized conditions, the linear range was found to be from 1.0 × 10?8 to 1.0 × 10?5 g/mL with a detection limit of 2.8 × 10?9 g/mL (3σ). The recoveries for the determination of THP in tablets were from 98.2 to 99.6%.  相似文献   

9.
A simple and highly sensitive chemiluminescence (CL) method is reported for the determination of naphazoline hydrochloride (NH). It was found that the weak CL from the reaction of luminol and KIO4 in an alkaline medium could be highly amplified by cysteine‐capped cadmium telluride quantum dots (QDs) and the enhanced CL was effectively quenched by NH and this finding was utilized as a basis for the determination of NH. The QDs were synthesized in aqueous medium and characterized by X‐ray diffraction (XRD), transmission electron microscopy (TEM), and UV‐vis and photoluminescence spectroscopy. A possible mechanism was proposed for the CL system based on radical identification experiments, along with CL spectrum of the system. The experimental parameters were optimized by the reliable response surface methodology (RSM). Under the optimized experimental conditions, the proposed method allowed the determination of NH over the range of 5.0 × 10‐10–2.0 × 10‐7 mol/L (r2 = 0.9993, n = 10). The precision (RSD%) of the method, obtained from five replicate determinations of 2.0 and 150 nmol/L NH, was found to be 1.0% and 1.3%, respectively. The method was successfully applied to the determination of NH in pharmaceutical formulations and human urine and serum samples with results corroborated with the aid of those obtained from a standard method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
A rapid and sensitive flow injection chemiluminescence (FI–CL) method is described for the determination of 2‐methoxyestradiol (2ME) based on enhancement of the CL intensity from a potassium ferricyanide–calcein system in sodium hydroxide medium. The optimum conditions for the CL emission were investigated. Under optimized conditions, a linear calibration graph was obtained over the range 1.0 × 10‐8 to 1.0 × 10‐6 mol/L (r = 0.998) 2ME with a detection limit (3σ) of 5.4 × 10‐9 mol/L. The relative standard deviation (RSD) for 5.0 × 10‐7 mol/L 2ME was 1.7%. As a preliminary application, the proposed method was successfully applied to the determination of 2ME in injection solutions and serum samples. The possible CL mechanism was also proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
We report herein an effective strategy for encapsulating Escherichia coli in polyethylene glycol diacrylate (PEGDA) microdroplets using a microfluidic device and chemical polymerization. PEGDA was employed as a reactant due to the biocompatibility, high porosity, and hydrophilic property. The uniform size and shape of microdroplets are obtained in a single‐step process using microfluidic device. The size of microdroplets can be controlled through the changing continuous flow rate. The combination of microdroplet generation and chemical polymerization techniques provide unique environment to produce non‐toxic ways of fabricating microorganism‐encapsulated hydrogel microbeads. Due to these unique properties of micro‐sized hydrogel microbeads, the encapsulated E. coli can maintain viability inside of microbeads and green fluorescent protein (GFP) and red fluorescent protein (RFP) genes are efficiently expressed inside of microbeads after isopropyl‐β‐D ‐thiogalactopyranoside induction, suggesting that there is no low‐molecular weight substrate transfer limitation inside of microbeads. Furthermore, non‐toxic, gentle, and outstanding biocompatibility of microbeads, the encapsulated E. coli can be used in various applications including biotransformation, biosensing, bioremediation, and engineering of artificial cells. Biotechnol. Bioeng. 2010;107:747–751. © 2010 Wiley Periodicals, Inc.  相似文献   

12.
A simple and sensitive chemiluminescence (CL) method has been developed for the determination of ampicillin sodium at submicromolar levels. The method is based on the inhibitory effect of ampicillin sodium on the cupric oxide nanoparticles (CuO NPs)–luminol–H2O2 CL reaction. Experimental parameters affecting CL inhibition including concentrations of CuO NPs, luminol, H2O2 and NaOH were optimized. Under optimum conditions, the calibration plot was linear in the analyte concentration range 4.0 × 10‐7–4.0 × 10‐6 mol/L. The limit of detection was 2.6 × 10‐7 mol/L and the relative standard deviation (RSD) for six replicate determinations of 1 × 10‐6 mol/L ampicillin sodium was 4.71%. Also, X–ray diffraction (XRD) and transmission electron microscopy (TEM) analysis were employed to characterize the CuO NPs. The utility of the proposed method was demonstrated by determining ampicillin sodium in pharmaceutical preparation. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid, novel and cost-effective spectrofluorimetric method developed to determine moxifloxacin (MFX) in pharmaceutical preparations because MFX in a pH 10 medium could reduce the fluorescence intensity of l -tryptophan. The maximum fluorescence excitation and emission wavelengths were found to be 280 and 363 nm respectively. A range of factors affecting fluorescence quenching and the effect of co-existing substances were investigated. Fluorescence quenching values (ΔF = FL-tryptophanFMoxi-L-tryptophan) displayed a strong linear relationship with the MFX concentration ranging from 0.2 to 8.0 μg/ml under optimum conditions. The limit of detection was found to be 6.1 × 10−4 μg/ml. The proposed method was shown to be suitable for MFX determination in pharmaceutical tablets and biological fluids by the linearity, recovery and limit of detection. The spectrofluorimetric approach that has been developed is extremely eco-friendly, as evidenced by the fact that all the experimental components and solvents were safe for the environment.  相似文献   

14.
近年来,随着微流体技术和生物微电子机械系统技术的不断发展,人类中枢神经系统(CNS)的微流体平台及相关疾病的体外模型逐渐得到了广泛的研究。微流体平台可以更好地模拟体内环境,同时能够控制结构、微环境和外来刺激。文中总结了微流控芯片在CNS的基本技术和CNS疾病中的应用。此外,文中对微流控芯片在CNS中的研究进行了展望,强调了通过跨学科的共同努力能够实现更高程度的仿生学挑战。  相似文献   

15.
A novel phenomenon of dual chemiluminescence (CL) was observed for the KIO4–luminol–Mn2+ system in strong alkaline solutions using the stopped‐flow technique. Scavenging study of the reactive oxygen species (ROS) suggested that the two CL peaks originated from different CL pathways precipated by distinct ROS (O2? and ?OH for the first peak, mainly 1O2 for the second peak). Generation of these ROS at different time intervals from the reactions involving IO4?, O2, and Mn2+ and their subsequent reactions with luminol induced the intense CL emission. The relative intensity of the two CL peaks can be tuned over a wide range by varying the concentrations of Mn2?, luminol and KIO4. Because of the involvement of different ROS in each pathway, the two CL peaks could respond quite differently to various substances. Moreover, variation of the intensity ratio of the two CL peaks altered the relative proportions of the corresponding ROS, thereby changing their responses to a given substance. The dual CL emission acts like a pair of tunable probes and it is believed that this CL system has great potential in analytical applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Visible oscillating chemiluminescence (CL) of luminol–H2O2–KSCN–CuSO4 was studied using the organic base (2‐hydroxyethyl)trimethylammonium hydroxide. The effect of concentrations of luminol, H2O2, KSCN, CuSO4 and the base were investigated in a batch reactor. This report shows how the concentration of components involved in the oscillating CL system influenced the oscillation period, light amplitude and total time of light emission. The oscillating CL with different bases was also investigated. Results indicated that using 2‐HETMAOH causes regular oscillating CL with nearly the same oscillating period. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
A novel flow‐injection chemiluminescence (FI‐CL) method is described for the determination of 2‐methoxyestradiol (2‐ME). The method is based on the inhibitory effect of 2‐ME on the CL reaction of luminol and potassium ferricyanide in alkaline solution. Under optimal conditions, net CL intensity was proportional to 2‐ME concentration in synthetic and mouse plasma samples. Corresponding linear regression equations were 8.0 x 10‐9‐1.0 x 10‐7g/mL for synthetic samples and 2.0 x 10‐9‐1.0 x 10‐7g/mL for plasma samples. Detection limit for synthetic samples and limits for quantification of plasma samples were 8.4 x 10‐10g/mL (3σ) for synthetic samples and 4.0 x 10‐9g/mL for mouse samples. A complete analysis was performed for 60 s, including washing and sampling, resulting in a throughput of ≈ 60/h. The proposed method was applied for the determination of 2‐ME in synthetic and mouse plasma samples. Percentage recoveries were 101.0‐102.8% and 98.0‐105.0%, respectively. A possible mechanism responsible for CL reaction is proposed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
A sensitive flow‐injection chemiluminescence method for the determination of acetylsalicylic acid is described. It is based on the enhanced chemiluminescent emission of the alkaline lucigenin–H2O2 system by acetylsalicylic acid. The difference in chemiluminescent intensity of alkaline lucigenin–H2O2 in the presence of acetylsalicylic acid from that in the absence of acetylsalicylic acid was linear at acetylsalicylic acid concentrations in the range of 0.0029–47.37 µg/mL, with detection and quantification limits of 0.0011 and 0.0029 µg/mL, respectively. The correlation coefficient of the working curve was 0.9983. The relative standard deviation (n = 10) for 25 µg/mL acetylsalicylic acid is 1.95%. All experimental parameters were optimized. The method was successfully applied to the determination of acetylsalicylic acid in pharmaceutical preparations. The recovery results obtained by the method were satisfactory. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order‐transform second‐chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow‐injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order‐transform second‐chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV‐visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10?7–5.0 × 10?5 mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10?8 mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10?6 mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
A simple and highly selective on‐chip Ru(bpy)32+–oxidant chemiluminescence (CL) approach for estimation of a diuretic drug, hydrochlorothiazide (HCZ), in biological fluids was realized in the presence of other fixed‐dose combination drugs by manipulating simultaneously the method of active species (Ru(bpy)33+) production and type of carrier buffer with pH used for the CL reaction. Chemical oxidation processes involved in the Ru(bpy)32+–Ce(IV) CL system have been successfully miniaturised in this study using a microfabricated device to generate Ru(bpy)33+ instantaneously. The proposed system was then screened using HCZ and other drugs in the presence of various buffers and pH to explore the difference in CL emission. Ammonium formate buffer (0.15 M) at pH 4.5 exhibited excellent selectivity towards HCZ when Ru(bpy)33+ was produced by chemical oxidation using Ce(IV). The newly developed conditions do not involve any kind of prior separation or isolation procedure to remove other combination therapy drugs in formulation and biological samples. The method under fully optimised conditions exhibited wide linearity over the concentration range 0.5–1000 ng ml?1 and low detection and quantification limits of 0.13 and 0.47 ng ml?1 respectively for HCZ. Acceptable levels of recoveries were obtained for HCZ from human plasma using the proposed method (98.9–100.8%) in the presence of other antihypertensive combination therapy drugs. This study postulates that such miniaturised devices may find applications especially for on‐site analysis, such as doping control examinations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏