首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A sensitive label-free electrochemical aptasensor was successfully fabricated for thrombin detection with nafion@graphene as platform. With electrostatic interaction between nafion and methylene blue (MB), positive charged MB was successfully assembled on nafion@graphene modified electrode surface, which provided amounts of redox probes for electrochemical aptasensor. In the presence of thrombin, the thrombin aptamer (TBA) on the electrode surface would catch the target on the electrode interface, which made a barrier for electrons and inhibits the electro-transfer, resulting in the decreased differential pulse voltammetry signals of MB. As a result, the proposed approach showed a high sensitivity and a wider linearity to thrombin in the range 0.01–50 nM with a detection limit of 6 pM.  相似文献   

2.
A label-free and sensitive faradic impedance spectroscopy (FIS) aptasensor based on target-induced aptamer displacement was developed for the determination of lysozyme as a model system. The aptasensor was fabricated by self-assembling the partial complementary single strand DNA (pcDNA)–lysozyme binding aptamer (LBA) duplex on the surface of a gold electrode. To measure lysozyme, the change in interfacial electron transfer resistance of the aptasensor using a redox couple of [Fe(CN)6]3−/4− as the probe was monitored. The introduction of target lysozyme induced the displacement of the LBA from the pcDNA–LBA duplex on the electrode into the solution, decreasing the electron transfer resistance of the aptasensor. The decrease in the FIS signal is linear with the concentration of lysozyme in the range from 0.2 nM to 4.0 nM, with a detection limit of 0.07 nM. The fabricated aptasensor shows a high sensitivity, good selectivity and satisfactory regeneration. This work demonstrates that a high sensitivity of the fabricated aptasensor can be obtained using a relatively short pcDNA. This work also demonstrates that the target-induced aptamer displacement strategy is promising in the design of an electrochemical aptasensor for the determination of lysozyme with good selectivity and high sensitivity.  相似文献   

3.
A novel electrochemical aptasensor based on hybridization chain reaction (HCR) with enzyme-signal amplification was constructed for the detection of interferon-gamma (IFN-γ). In this aptasensor, the recognition probes which contained the sequence of IFN-γ aptamer were initially binded to IFN-γ, and the unbound recognition probes were captured on the electrode as an initiator to trigger the HCR. The two DNA hairpins bio-H1 and bio-H2 were opened by the recognition probe, and bound one by one on the electrode. The biotin was used as a tracer in the hairpins and streptavidin-alkaline phosphatase (SA-ALP) as a reporter molecule. Then, SA-ALP converted its electro-inactive substrate 1-naphthyl phosphate into an electroactive derivative 1-naphthol generating amplified electrochemical signal by differential pulse voltammetry (DPV). The activity of the immobilized enzyme was voltammetrically determined by measuring the amount of 1-naphthol generated for enzymatic dephosphorylation of 1-naphthyl phosphate. The electrochemical signal observed was inversely related to the concentration of IFN-γ. The proposed approach showed a high sensitivity for IFN-γ in a concentration range of 0.5-300 nM with a detection limit of 0.3 nM. The sensing system also provided satisfactory results for the detection of IFN-γ in the cell media.  相似文献   

4.
A well-designed three-way junction (TWJ) aptasensor for lysozyme detection was developed based on target-binding-induced conformational change of aptamer-complementary DNA (cDNA) as probe. A ferrocene (Fc)-tagged cDNA is partially hybridized with an anti-lysozyme aptamer to form a folded structure where there is a coaxial stacking of two helices and the third one at an acute angle. In addition, the fabrication of the sensor was achieved via the single-step method, which offered a good condition for sensing. In the absence of lysozyme, electron transfer (eT), through the coaxial two helices called "conductive path", is allowed between Fc-labeled moiety and the electrode. The binding of lysozyme to the aptamer blocks eT, leading to diminished redox signal. This aptasensor with an instinct signal attenuation factor shows a high sensitivity to lysozyme, and the response data is fitted by nonlinear least-squares to Hill equation. Detection limit is 0.2nM with a dynamic range extending to 100nM. Compared with existing electrochemical impedance spectroscopy (EIS)-based approaches, TWJ-DNA aptasensor was demonstrated to be more specific for detection and simpler for regeneration procedure.  相似文献   

5.
Angiogenin (Ang), one of the most potent angiogenic factor, is related with the growth and metastasis of numerous tumors. This paper presents a very simple and label-free square-wave voltammetry (SWV) aptasensor to detect angiogenin, in which an anti-angiogenin-aptamer was used as a molecular recognition element, and the couple ferro/ferricyanide as a redox probe. At the bare gold electrode, the redox couple (K4[Fe(CN)6]/K3[Fe(CN)6]) can be very easily accessed to the electrode surface to give a very strong SWV signal. At the anti-angiogenin/Au electrode surface, when angiogenin was added to the electrochemical cell, the binding of the analyte results in less availability for a redox reaction, which led to smaller SWV current. To quantify the amount of angiogenin, current suppressions of SWV peak were monitored using the redox couple of an [Fe(CN)6]4−/3− probe. The plot of signal suppression against the logarithm of angiogenin concentration is linear with over the range from 0.01 nM to 30 nM with a detection limit of 1 pM. The aptasensor also showed very good selectivity for angiogenin without being affected by the presence of other proteins in serum. It is the first time to use a very simple method to detect the cancer marker. Such an aptasensor opens a rapid, selective and sensitive route for angiogenin detection and provides a promising strategy for other protein detections.  相似文献   

6.
Here, an ultrasensitive label-free electrochemical aptasensor was developed for dopamine (DA) detection. Construction of the aptasensor was carried out by electrodeposition of gold–platinum nanoparticles (Au–PtNPs) on glassy carbon (GC) electrode modified with acid-oxidized carbon nanotubes (CNTs–COOH). A designed complementary amine-capped capture probe (ssDNA1) was immobilized at the surface of PtNPs/CNTs–COOH/GC electrode through the covalent amide bonds formed by the carboxyl groups on the nanotubes and the amino groups on the oligonucleotides. DA-specific aptamer was attached onto the electrode surface through hybridization with the ssDNA1. Methylene blue (MB) was used as an electrochemical indicator that was intercalated into the aptamer through the specific interaction with its guanine bases. In the presence of DA, the interaction between aptamer and DA displaced the MB from the electrode surface, rendering a lowered electrochemical signal attributed to a decreased amount of adsorbed MB. This phenomenon can be applied for DA detection. The peak current of probe (MB) linearly decreased over a DA concentration range of 1–30 nM with a detection limit of 0.22 nM.  相似文献   

7.
Yuan Y  Gou X  Yuan R  Chai Y  Zhuo Y  Mao L  Gan X 《Biosensors & bioelectronics》2011,26(10):4236-4240
A simple electrochemical aptasensor for sensitive detection of thrombin was fabricated with G-quadruplex horseradish peroxidase-mimicking DNAzyme (hemin/G-quadruplex system) and blocking reagent-horseradish peroxidase as dual signal-amplification scheme. Gold nanoparticles (nano-Au) were firstly electrodeposited onto single wall nanotube (SWNT)-graphene modified electrode surface for the immobilization of electrochemical probe of nickel hexacyanoferrates nanoparticles (NiHCFNPs). Subsequently, another nano-Au layer was electrodeposited for further immobilization of thrombin aptamer (TBA), which later formed hemin/G-quadruplex system with hemin. Horseradish peroxidases (HRP) then served as blocking reagent to block possible remaining active sites and avoided the non-specific adsorption. In the presence of thrombin, the TBA binded to thrombin and the hemin released from the hemin/G-quadruplex electrocatalytic structure, increasing steric hindrance of the aptasensor and decomposing hemin/G-quadruplex electrocatalytic structure, which finally decreased the electrocatalytic efficiency of aptasensor toward H(2)O(2) in the presence of NiHCFNPs with a decreased electrochemical signal. On the basis of the synergistic amplifying action, a detection limit as low as 2 pM for thrombin was obtained.  相似文献   

8.
In this paper, dendritic gold nanostructure (DenAu) modified electrode was obtained by direct electrodeposition of planar electrode into 2.8 mM HAuCl(4) and 0.1 M H(2)SO(4) solution under a very negative potential of -1.5 V. Scanning electron microscopy was used to characterize the growth evolution of DenAu with time. The whole DNA biosensor fabrication process based on the DenAu modified electrode was characterized by cyclic voltammetry and electrochemical impedance spectroscopy methods with the use of ferricyanide as an electrochemical redox indicator. The probe DNA immobilization and hybridization with target DNA on the modified electrode could be well distinguished by using methylene blue as an electrochemical hybridization indicator. The DenAu modified electrode could realize an ultra sensitivity of 1 fM toward complementary target DNA and a very wide dynamic detection range (from 1 fM to 1 nM).  相似文献   

9.
A sensitive label-free electrochemical aptasensor was successfully fabricated for thrombin detection with platinum nanoparticles (Pt) and blocking reagent horseradish peroxidase (HRP) as enhancers. A Nafion?-graphene-coated electrode was first modified with an electrochemical probe of methylene blue (MB) through electrostatic interaction. Then Pt was electrodeposited onto an electrode for immobilization of the thrombin aptamer (TBA). Subsequently, HRP served as blocking reagent instead of bovine serum albumin (BSA). With the synergistic effect between Pt and HRP, the prepared aptasensor showed a superior catalytic efficiency toward H(2) O(2) in the presence of MB. After the combination of target thrombin on electrode surface, the TBA-thrombin complex made a barrier for electrocatalysis of Pt and HRP and inhibited the electrotransfer, resulting in a greater decrease in MB signals. As a result, the proposed approach showed a high sensitivity and a much wider linearity to thrombin in the range from 0.005 to 50 nM with a detection limit of 1 pM.  相似文献   

10.
A direct electrochemical DNA biosensor based on zero current potentiometry was fabricated by immobilization of ssDNA onto gold nanoparticles (AuNPs) coated pencil graphite electrode (PGE). One ssDNA/AuNPs/PGE was connected in series between clips of working and counter electrodes of a potentiostat, and then immersed into the solution together with a reference electrode, establishing a novel DNA biosensor for specific DNA detection. The variation of zero current potential difference (ΔE(zcp)) before and after hybridization of the self-assembled probe DNA with the target DNA was used as a signal to characterize and quantify the target DNA sequence. The whole DNA biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the use of ferricyanide as an electrochemical redox indicator. Under the optimized conditions, ΔE(zcp) was linear with the concentrations of the complementary target DNA in the range from 10nM to 1μM, with a detection limit of 6.9nM. The DNA biosensor showed a good reproducibility and selectivity. Prepared DNA biosensor is facile and sensitive, and it eliminates the need of using exogenous reagents to monitor the oligonucleotides hybridization.  相似文献   

11.
In this study, we developed an ultrasensitive label-free aptamer-based electrochemical biosensor, featuring a highly specific anti-human immunoglobulin E (IgE) aptamer as a capture probe, for human IgE detection. Construction of the aptasensor began with the electrodeposition of gold nanoparticles (AuNPs) onto a graphite-based screen-printed electrode (SPE). After immobilizing the thiol-capped anti-human IgE aptamer onto the AuNPs through self-assembly, we treated the electrode with mercaptohexanol (MCH) to ensure that the remaining unoccupied surfaces of the AuNPs would not undergo nonspecific binding. We employed a designed complementary DNA featuring a guanine-rich section in its sequence (cDNA G1) as a detection probe to bind with the unbound anti-human IgE aptamer. We measured the redox current of methylene blue (MB) to determine the concentration of human IgE in the sample. When the aptamer captured human IgE, the binding of cDNA G1 to the aptamer was inhibited. Using cDNA G1 in the assay greatly amplified the redox signal of MB bound to the detection probe. Accordingly, this approach allowed the linear range (coefficient of determination: 0.996) for the analysis of human IgE to extend from 1 to 100,000pM; the limit of detection was 0.16pM. The fabricated aptasensor exhibited good selectivity toward human IgE even when human IgG, thrombin, and human serum albumin were present at 100-fold concentrations. This method should be readily applicable to the detection of other analytes, merely by replacing the anti-human IgE aptamer/cDNA G1 pair with a suitable anti-target molecule aptamer and cDNA.  相似文献   

12.
Hu Y  Hua S  Li F  Jiang Y  Bai X  Li D  Niu L 《Biosensors & bioelectronics》2011,26(11):4355-4361
Sensitive electrochemical impedance assay of DNA hybridization by using a novel graphene sheets platform was achieved. The graphene sheets were firstly functionalized with 3,4,9,10-perylene tetracarboxylic acid (PTCA). PTCA molecules separated graphene sheets efficiently and introduced more negatively-charged -COOH sites, both of which were beneficial to the decoration of graphene with gold nanoparticles. Then amine-terminated ionic liquid (NH?-IL) was applied to the reduction of HAuCl? to gold nanoparticles. The green-synthesized gold nanoparticles, with the mean diameter of 3 nm, dispersed uniformly on graphene sheets and its outer layer was positively charged imidazole termini. Due to the presence of large graphene sheets and NH?-IL protected gold nanoparticles, DNA probes could be immobilized via electrostatic interaction and adsorption effect. Electrochemical impedance value increased after DNA probes immobilization and hybridization, which was adopted as the signal for label-free DNA hybridization detection. Unlike previously anchoring DNA to gold nanoparticles, this label-free method was simple and noninvasive. The conserved sequence of the pol gene of human immunodeficiency virus 1 was satisfactorily detected via this strategy.  相似文献   

13.
Zhao J  He X  Bo B  Liu X  Yin Y  Li G 《Biosensors & bioelectronics》2012,34(1):249-252
In this paper, we report a "signal-on" electrochemical aptasensor for simultaneous determination of two tumor markers MUC1 and VEGF(165), by using a ferrocene-labeled aptamer-complementary DNA (cDNA) as probe. Since the cDNA immobilized on an electrode surface can hybridize with both MUC1 aptamer and VEGF(165) aptamer to form a long double strand with ferrocene far away from the electrode surface, the probe cannot give electrochemical signal. Nevertheless, the presence of the two tumor markers will inhibit the hybridization of cDNA with the aptamers, thus the distance between ferrocene and the electrode is changed, and a "signal-on" electrochemical method to detect two tumor markers is developed. Experimental results show that the electrochemical signal increases with the addition of either tumor markers, but the biggest electrochemical signal can only be obtained when both tumor markers are present. Therefore, the proposed electrochemical aptasensor can not only detect the two markers but also distinguish their co-existence. It may also display high selectivity and sensitivity towards the detection of the tumor markers, so it might have potential clinical application in the future.  相似文献   

14.
For the detection of DNA hybridization, a new electrochemical biosensor was developed on the basis of the interaction of hematoxylin with 20-mer deoxyoligonucleotides (from human papilloma virus, HPV). The study was performed based on the interaction of hematoxylin with an alkanethiol DNA probe self-assembled gold electrode (ss-DNA/AuE) and its hybridization form (ds-DNA/AuE). The optimum conditions were found for the immobilization of HPV probe on the gold electrode (AuE) surface and its hybridization with the target DNA. Electrochemical detection of the self-assembled DNA and the hybridization process were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over the potential range where the accumulated hematoxylin at the modified electrode was electroactive. Observing a remarkable difference between the voltammetric signals of the hematoxylin obtained from different hybridization samples (non-complementary, mismatch and complementary DNAs), we confirmed the potential of the developed biosensor in detecting and discriminating the target complementary DNA from non-complementary and mismatch oligonucleotides. Under optimum conditions, the electrochemical signal had a linear relationship with the concentration of the target DNA ranging from 12.5 nM to 350.0 nM, and the detection limit was 3.8 nM.  相似文献   

15.
A simple electrochemical aptasensor was developed for ultrasensitive protein detection by combining a novel strategy of cyclic target-induced primer extension (CTIPE) with an aptamer-hairpin probe and enzyme-amplified electrochemical readout. In the presence of protein target, the immobilized aptamer-hairpin probe recognized the protein to trigger primer extension reaction by target-induced conformational transition, which released the protein from replicated DNA duplex. The released target could cyclically bind with other aptamer-hairpin probes and trigger new primer extension, leading to formation of numerous biotin-tagged DNA duplex, which significantly amplified the protein recognition event and facilitated the subsequent enzymatic signal enhancement, leading to an ultrasensitive electrochemical aptasensor. Using human vascular endothelial growth factor as a model protein, the designed aptasensor could detect protein down to 0.82 pg mL(-1) with a linear range from 1 pg mL(-1) to 1 ng mL(-1). The proposed aptasensor was amenable to quantification of protein in complex biological matrixes, and would become a simple and powerful tool for bioanalysis and clinic diagnostic application.  相似文献   

16.
Single polypyrrole (PPy) nanowire-based microfluidic aptasensors were fabricated using a one-step electrochemical deposition method. The successful incorporation of the aptamers into the PPy nanowire was confirmed by fluorescence microscopy image. The microfluidic aptasensor showed responses to IgE protein solutions in the range from 0.01 nM to 100 nM, and demonstrated excellent specificity and sensitivity with faster response and rapid stabilization times (~20 s). At the lowest examined IgE concentration of 0.01 nM, the microfluidic aptasensor still exhibited ~0.32% change in the conductance. The functionality of this aptasensor was able to be regenerated using an acid treatment with no major change in sensitivity. In addition, the detection of cancer biomarker MUC1 was performed using another microfluidic aptasensor, which showed a very low detection limit of 2.66 nM MUC1 compared to commercially available MUC1 diagnosis assay (800 nM).  相似文献   

17.
We developed a novel electrochemical sensor for Hg(2+) detection using two mercury-specific oligonucleotide probes and streptavidin-horseradish peroxidase (HRP) enzymatic signal amplification. The two mercury-specific oligonucleotide probes comprised a thiolated capture probe and a biotinated signal probe. The thiolated capture probe was immobilized on a gold electrode. In the presence of Hg(2+), the thymine-Hg(2+)-thymine (T-Hg(2+)-T) interaction between the mismatched T-T base pairs directed the biotinated signal probe hybridizing to the capture probe and yielded a biotin-functioned electrode surface. HRP was then immobilized on the biotin-modified substrate via biotin-streptavidin interaction. The immobilized HRP catalyzed the oxidation of hydroquinone (H(2)Q) to benzoquinone (BQ) by hydrogen peroxide (H(2)O(2)) and the generated BQ was further electrochemically reduced at the modified gold electrode, producing a readout signal for quantitative detection of Hg(2+). The results showed that the enzyme-amplified electrochemical sensor system was highly sensitive to Hg(2+) in the concentration of 0.5 nM to 1 μM with a detection limit of 0.3 nM, and it also demonstrated excellent selectivity against other interferential metal ions.  相似文献   

18.
Electrochemical aptasensor for tetracycline detection   总被引:1,自引:0,他引:1  
An electrochemical aptasensor was developed for the detection of tetracycline using ssDNA aptamer that selectively binds to tetracycline as recognition element. The aptamer was highly selective for tetracycline which distinguishes minor structural changes on other tetracycline derivatives. The biotinylated ssDNA aptamer was immobilized on a streptavidin-modified screen-printed gold electrode, and the binding of tetracycline to aptamer was analyzed by cyclic voltammetry and square wave voltammetry. Our results showed that the minimum detection limit of this sensor was 10 nM to micromolar range. The aptasensor showed high selectivity for tetracycline over the other structurally related tetracycline derivatives (oxytetracycline and doxycycline) in a mixture. The aptasensor developed in this study can potentially be used for detection of tetracycline in pharmaceutical preparations, contaminated food products, and drinking water.  相似文献   

19.
Here, we describe the fabrication of an electrochemical immunoglobulin E (IgE) aptasensor using enzyme-linked aptamer in the sandwich assay method and thionine as redox probe. In this protocol, 5′-amine-terminated IgE aptamer and thionine were covalently attached on glassy carbon electrode modified with carbon nanotubes/ionic liquid/chitosan nanocomposite. Furthermore, another IgE aptamer was modified with biotin and enzyme horseradish peroxidase (HRP), which attached to the aptamer via biotin–streptavidin interaction. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry were performed at each stage of the chemical modification process to confirm the resulting surface changes. The presence of IgE induces the formation of a double aptamer sandwich structure on the electrode, and the electrocatalytic reduction current of thionine in the presence of hydrogen peroxide was measured as the sensor response. Under optimized conditions and using differential pulse voltammetry as the measuring technique, the proposed aptasensor showed a low detection limit (6 pM) and high sensitivity (1.88 μA nM−1). This aptasensor also exhibited good stability and high selectivity for IgE detection without an interfering effect of some other proteins such as bovine serum albumin (BSA) and lysozyme. The application of the aptasensor for IgE detection in human serum sample was also investigated. The proposed protocol is quite promising as an alternative sandwich approach for various protein assays.  相似文献   

20.
A novel strategy for the fabrication of an electrochemical aptasensor is proposed; this strategy has been employed in this work to assay thrombin concentration. Two well-designed oligonucleotides were used as the core element. G-quadruplex–hemin complexes can be formed on the surface of the electrode to give a detectable signal only when thrombin is not bound to the aptamers. The detection limit of the biosensor has been lowered to 10 nM. Moreover, since the electroactive probe is not required to be bound to the oligonucleotide, this strategy may integrate the advantages of being both label-free and cost-effective.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号