首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Fluorescence microscopy (FM) has not been implemented widely in TB endemic settings and little evaluation has been done in HIV-infected patients. We evaluated diagnostic performance, time and costs of FM with light-emitting diodes technology (LED-FM), compared with conventional (Zieh-Neelsen) microscopy in a hospital in Indonesia which acts as referral centre for HIV-infected patients.

Method

We included pulmonary tuberculosis suspects from the outpatient and HIV clinic. Direct and concentrated sputum smears were examined using LED-FM and ZN microscopy by two technicians who were blinded for the HIV-status and the result of the comparative test. Mean reading time per slide was recorded and cost of each slide was calculated. Mycobacteria culture served as the reference standard.

Results

Among 404 tuberculosis suspects from the outpatient clinic and 256 from the HIV clinic, mycobacteria culture was positive in 12.6% and 27%, respectively. The optimal sensitivity of LED-FM was achieved by using a threshold of ≥2 AFB/length. LED-FM had a higher sensitivity (75.5% vs. 54.9%, P<0.01) but lower specificity (90.0% vs 96.6%, P<0.01) compared to ZN microscopy. HIV was associated with a lower sensitivity but similar specificity. The average reading time using LED-FM was significantly shorter (2.23±0.78 vs 5.82±1.60 minutes, P<0.01), while costs per slide were similar.

Conclusion

High sensitivity of LED-FM combined with shorter reading time of sputum smear slides make this method a potential alternative to ZN microscopy. Additional data on specificity are needed for effective implementation of this technique in high burden TB laboratories.  相似文献   

2.

Background

Sputum microscopy is the only diagnostic for tuberculosis (TB) available at peripheral levels of health service in resource-poor countries. Its sensitivity is reduced in high HIV-prevalence settings. Sodium hypochlorite (NaOCl) specimen sedimentation prior microscopy and light-emitting diode (LED)-fluorescence microscopy (FM) can individually improve performance of microscopy. This study aimed to evaluate the performance of combined LED-FM and NaOCl sputum sedimentation for TB detection at peripheral level of health services.

Methods

A prospective study was conducted in an urban health clinic in Nairobi, Kenya. Three sputum specimens were collected over 2 days from consecutive TB suspects. Smears were prepared and stained with auramine O and Ziehl-Neelsen (ZN) methods. Bleach (3.5%) was added to the remaining specimen before overnight sedimentation at room temperature. Auramine O staining was performed on smears of sediment. A 4th specimen was collected for TB culture. Auramine smears were read under the same microscope as used for ZN smears, but equipped with the LED FluoLED™ fluorescence illuminator.

Results

497 patients were included, and 1394 specimens collected. The yield of positive specimen was significantly increased after NaOCl sedimentation (24.9%) compared to direct LED-FM (20.6%) and direct ZN (20.3%). In detecting smear-positive patients, sensitivity was 78.5% for LED-FM after NaOCl sedimentation compared to 73.2% and 72.0% for direct LED-FM (P = 0.06) and direct ZN (P = 0.06), respectively. Specificity was 87.8% for LED-FM after NaOCl sedimentation compared to 96.7% and 95.9% for direct LED-FM (P<0.01) and direct ZN (P<0.01), respectively. Inter-reading agreement (kappa = 0.7) and technicians'' acceptability were good.

Conclusion

NaOCl sedimentation did not improve the performance of LED-FM in the diagnosis of pulmonary TB at peripheral health service level.  相似文献   

3.

Background

Sputum microscopy is the only tuberculosis (TB) diagnostic available at peripheral levels of care in resource limited countries. Its sensitivity is low, particularly in high HIV prevalence settings. Fluorescence microscopy (FM) can improve performance of microscopy and with the new light emitting diode (LED) technologies could be appropriate for peripheral settings. The study aimed to compare the performance of LED-FM versus Ziehl-Neelsen (ZN) microscopy and to assess feasibility of LED-FM at a low level of care in a high HIV prevalence country.

Methods

A prospective study was conducted in an urban health clinic in Nairobi, Kenya. Three sputum specimens were collected over 2 days from suspected TB patients. Each sample was processed with Auramine O and ZN methods and a 4th specimen was collected for TB culture reference standard. Auramine smears were read using the same microscope, equipped with the FluoLED™ fluorescence illuminator. Inter-reader agreement, reading time and technicians'' acceptability assessed feasibility.

Results

497 patients were included and 1394 specimens were collected. The detection yields of LED-FM and ZN microscopy were 20.3% and 20.6% (p = 0.64), respectively. Sensitivity was 73.2% for LED-FM and 72% for ZN microscopy, p = 0.32. It was 96.7% and 95.9% for specificity, p = 0.53. Inter-reader agreement was high (kappa = 0.9). Mean reading time was three times faster than ZN microscopy with very good acceptance by technicians.

Conclusions

Although it did not increase sensitivity, the faster reading time combined with very good acceptance and ease of use supports the introduction of LED-FM at the peripheral laboratory level of high TB and HIV burden countries.  相似文献   

4.

Background

Direct sputum smear microscopy for tuberculosis (TB) lacks sensitivity for the detection of acid fast bacilli. Sputum pretreatment procedures may enhance sensitivity. We did a pilot study to compare the diagnostic accuracy and incremental yield of two short-duration (<1 hour) sputum pretreatment procedures to optimize direct smears among patients with suspected TB at a referral hospital in India.

Methodology/Findings

Blinded laboratory comparison of bleach and universal sediment processing (USP) pretreated centrifuged auramine smears to direct Ziehl-Neelsen (ZN) and direct auramine smears and to solid (Loweinstein-Jensen (LJ)) and liquid (BACTEC 460) culture. 178 pulmonary and extrapulmonary TB suspects were prospectively recruited during a one year period. Thirty six (20.2%) were positive by either solid or liquid culture. Direct ZN smear detected 22 of 36 cases and direct auramine smears detected 26 of 36 cases. Bleach and USP centrifugation detected 24 cases each, providing no incremental yield beyond direct smears. When compared to combined culture, pretreated smears were not more sensitive than direct smears (66.6% vs 61.1 (ZN) or 72.2 (auramine)), and were not more specific (92.3% vs 93.0 (ZN) or 97.2 (auramine).

Conclusions/Significance

Short duration sputum pretreatment with bleach and USP centrifugation did not increase yield as compared to direct sputum smears. Further work is needed to confirm this in a larger study and also determine if longer duration pre-treatment might be effective in optimizing smear microscopy for TB.  相似文献   

5.

Background

The diagnosis of tuberculosis (TB) in resource-limited settings relies on Ziehl-Neelsen (ZN) smear microscopy. LED fluorescence microscopy (LED-FM) has many potential advantages over ZN smear microscopy, but requires evaluation in the field. The aim of this study was to assess the sensitivity/specificity of LED-FM for the diagnosis of pulmonary TB and whether its performance varies with the timing of specimen collection.

Methods and Findings

Adults with cough ≥2 wk were enrolled consecutively in Ethiopia, Nepal, Nigeria, and Yemen. Sputum specimens were examined by ZN smear microscopy and LED-FM and compared with culture as the reference standard. Specimens were collected using a spot-morning-spot (SMS) or spot-spot-morning (SSM) scheme to explore whether the collection of the first two smears at the health care facility (i.e., “on the spot”) the first day of consultation followed by a morning sample the next day (SSM) would identify similar numbers of smear-positive patients as smears collected via the SMS scheme (i.e., one on-the-spot-smear the first day, followed by a morning specimen collected at home and a second on-the-spot sample the second day). In total, 529 (21.6%) culture-positive and 1,826 (74.6%) culture-negative patients were enrolled, of which 1,156 (49%) submitted SSM specimens and 1,199 (51%) submitted SMS specimens. Single LED-FM smears had higher sensitivity but lower specificity than single ZN smears. Using two LED-FM or two ZN smears per patient was 72.8% (385/529, 95% CI 68.8%–76.5%) and 65.8% (348/529, 95% CI 61.6%–69.8%) sensitive (p<0.001) and 90.9% (1,660/1,826, 95% CI 89.5%–92.2%) and 98% (1,790/1,826, 95% CI 97.3%–98.6%) specific (p<0.001). Using three LED-FM or three ZN smears per patient was 77% (408/529, 95% CI 73.3%–80.6%) and 70.5% (373/529, 95% CI 66.4%–74.4%, p<0.001) sensitive and 88.1% (95% CI 86.5%–89.6%) and 96.5% (95% CI 96.8%–98.2%, p<0.001) specific. The sensitivity/specificity of ZN smear microscopy and LED-FM did not vary between SMS and SSM.

Conclusions

LED-FM had higher sensitivity but, in this study, lower specificity than ZN smear microscopy for diagnosis of pulmonary TB. Performance was independent of the scheme used for collecting specimens. The introduction of LED-FM needs to be accompanied by appropriate training, quality management, and monitoring of performance in the field.

Trial Registration

Current Controlled Trials ISRCTN53339491 Please see later in the article for the Editors'' Summary  相似文献   

6.

Background

Each follow-up during the course of tuberculosis treatment currently requires two sputum examinations. However, the incremental yield of the second sputum sample during follow-up of different types of tuberculosis patients has never been determined precisely.

Objectives

To assess the incremental yield of the second sputum sample in the follow-up of tuberculosis patients under the Revised National Tuberculosis Control Programme (RNTCP) in Chhattisgarh, India.

Methodology

A record review of tuberculosis (TB) patients registered in 2009 using a structured proforma from two sources, Tuberculosis and Laboratory Register, was undertaken in the six districts of Chhattisgarh, India.

Results

In smear positive cases, of 10,048 follow-up examinations, 45 (0.5%) were found to be smear positive only on the second sputum when the result of the first sample was negative. In smear negative pulmonary and extra pulmonary TB patients, of 6,206 follow-up smear examinations, 11(0.2%) were found to be smear positive.

Conclusions

The incremental yield of a second smear examination was very low, indicating that examination of one sputum sample is enough during follow-up among TB patients. There is insufficient yield to support sputum smear microscopy for monitoring smear negative pulmonary TB and extra pulmonary TB patients. These results indicate that the follow-up smear microscopy can be substantially simplified with favourable resource implications.  相似文献   

7.

Background

Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings.

Methods

We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primostar™ iLED, Lumin™ and AFTER®) for fluorescent detection of Mycobacterium tuberculosis with ZN microscopy on slides prepared from sputum of TB suspects. Examination time for LED-based fluorescent microscopy (LED FM) and ZN slides was also compared, and a qualitative user appraisal of the LED FM systems was carried out.

Results

LED FM was between 5.6 and 9.4% more sensitive than ZN microscopy, although the difference was not statistically significant. There was no significant difference in the sensitivity or specificity of the three LED FM systems, although the specificity of Fraen AFTER was somewhat lower than the other LED FM methods. Examination time for LED FM was 2 and 4 times less than for ZN microscopy. LED FM was highly acceptable to Ugandan technologists, although differences in operational performance of the three systems were reported.

Conclusions

LED FM compares favourably with ZN microscopy, with equivalent specificity and a modest increase in sensitivity. Screening of slides was substantially quicker using LED FM than ZN, and LED FM was rated highly by laboratory technologists. Available commercial systems have different operational characteristics which should be considered prior to programmatic implementation.  相似文献   

8.

Background

Improving childhood tuberculosis (TB) evaluation and care is a global priority, but data on performance at community health centers in TB endemic regions are sparse.

Objective

To describe the current practices and quality of TB evaluation for children with cough ≥2 weeks'' duration presenting to community health centers in Uganda.

Methods

Cross-sectional analysis of children (<15 years) receiving care at five Level IV community health centers in rural Uganda for any reason between 2009–2012. Quality of TB care was assessed using indicators derived from the International Standards of Tuberculosis Care (ISTC).

Results

From 2009–2012, 1713 of 187,601 (0.9%, 95% CI: 0.4–1.4%) children presenting to community health centers had cough ≥ 2 weeks'' duration. Of those children, only 299 (17.5%, 95% CI: 15.7–19.3%) were referred for sputum microscopy, but 251 (84%, 95% CI: 79.8–88.1%) completed sputum examination if referred. The yield of sputum microscopy was only 3.6% (95% CI: 1.3–5.9%), and only 55.6% (95% CI: 21.2–86.3%) of children with acid-fast bacilli positive sputum were started on treatment. Children under age 5 were less likely to be referred for sputum examination and to receive care in accordance with ISTC. The proportion of children evaluated in accordance with ISTC increased over time (4.6% in 2009 to 27.9% in 2012, p = 0.03), though this did not result in increased case-detection.

Conclusion

The quality of TB evaluation was poor for children with cough ≥2 weeks'' duration presenting for health care. Referrals for sputum smear microscopy and linkage to TB treatment were key gaps in the TB evaluation process, especially for children under the age of five.  相似文献   

9.

Background

To quantify the likely impact of recent WHO policy recommendations regarding smear microscopy and the introduction of appropriate low-cost fluorescence microscopy on a) case detection and b) laboratory workload.

Methodology/Principal Findings

An audit of the laboratory register in an urban hospital, Lilongwe, Malawi, and the application of a simple modelling framework. The adoption of the new definition of a smear-positive case could directly increase case detection by up to 28%. Examining Ziehl-Neelsen (ZN) sputum smears for up to 10 minutes before declaring them negative has previously been shown to increase case detection (over and above that gained by the adoption of the new case definition) by 70% compared with examination times in routine practice. Three times the number of staff would be required to adequately examine the current workload of smears using ZN microscopy. Through implementing new policy recommendations and LED-based fluorescence microscopy the current laboratory staff complement could investigate the same number of patients, examining auramine-stained smears to an extent that is equivalent to a 10 minutes ZN smear examination.

Conclusions/Significance

Combined implementation of the new WHO recommendations on smear microscopy and LED-based fluorescence microscopy could result in substantial increases in smear positive case-detection using existing human resources and minimal additional equipment.  相似文献   

10.

Setting

National Tuberculosis Programme, Cambodia.

Objective

In a cohort of TB patients, to ascertain the proportion of patients who fulfil the criteria for presumptive MDR-TB, assess whether they underwent investigation for MDR-TB, and the results of the culture and drug susceptibility testing (DST).

Methods

A cross sectional record review of TB patients registered for treatment between July-December 2011.

Results

Of 19,236 TB patients registered, 409 (2%) fulfilled the criteria of presumptive MDR-TB; of these, 187 (46%) were examined for culture. This proportion was higher among relapse, failure, return after default (RAD) and non-converters at 3 months of new smear positive TB patients (>60%) as compared to non-converters at 2 months of new TB cases (<20%). Nearly two thirds (n = 113) of the samples were culture positive; of these, three-fourth (n = 85) grew Mycobacterium tuberculosis complex (MTBc) and one-fourth (n = 28) grew non-tuberculous Mycobacteria. DST results were available for 96% of the MTBc isolates. Overall, 21 patients were diagnosed as MDR-TB (all diagnosed among retreatment TB cases and none from non-converters) and all of them were initiated on MDR-TB treatment.

Conclusion

There is a need to strengthen mechanisms for linking patients with presumptive MDR-TB to culture centers. The policy of testing non-converters for culture and DST needs to be reviewed.  相似文献   

11.

Background

We aimed to determine the prevalence of pulmonary tuberculosis (TB) amongst the adult population in 2010–2011 in Pakistan.

Method

A nationwide cross-sectional survey with multistage cluster sampling was conducted among adults (≥15 years) in 95 clusters in 2010–2011. All consenting participants were screened for cough and by chest X-ray. Participants with presumptive TB submitted two sputum samples for smear microscopy, culture, and molecular testing if needed. The TB prevalence estimates were adjusted for missing data and the cluster design.

Result

Of 131,329 eligible individuals, 105,913 (81%) participated in the survey, of whom 10,471 (9.9%) were eligible for sputum examination. We found 341 bacteriologically positive TB cases of whom 233 had sputum smear-positive TB. The adjusted prevalence estimates for smear and bacteriologically positive TB were 270/100,000 (95% confidence interval (CI) 217–323), and 398/100,000 (95% CI 333–463), respectively. Only 61% of the diagnosed TB cases screened positive on symptoms (cough >2wks), whereas the other TB cases were detected based on X-ray abnormalities. The TB prevalence increased with age and was 1.8 times higher among men than women. The prevalence-to-notification ratio of smear-positive TB was 3.1 (95% CI 2.5–3.7), was higher among men than women, and increased with age.

Conclusion

Our data suggest that there is under-detection and/or -notification of TB, especially among men and elderly. TB control should be strengthened specifically in these risk groups. X-ray examination should be combined with symptom screening to enhance case detection.  相似文献   

12.

Background

Diagnosis followed by effective treatment of tuberculosis (TB) reduces transmission and saves lives in persons living with HIV (PLHIV). Sputum smear microscopy is widely used for diagnosis, despite limited sensitivity in PLHIV. Evidence is needed to determine the optimal diagnostic approach for these patients.

Methods

From May 2011 through June 2012, we recruited PLHIV from 15 HIV treatment centers in western Kenya. We collected up to three sputum specimens for Ziehl-Neelsen (ZN) and fluorescence microscopy (FM), GeneXpert MTB/RIF (Xpert), and culture, regardless of symptoms. We calculated the incremental yield of each test, stratifying results by CD4 cell count and specimen type; data were analyzed to account for complex sampling.

Results

From 778 enrolled patients, we identified 88 (11.3%) laboratory-confirmed TB cases. Of the 74 cases who submitted 2 specimens for microscopy and Xpert testing, ZN microscopy identified 25 (33.6%); Xpert identified those plus an additional 18 (incremental yield = 24.4%). Xpert testing of spot specimens identified 48 (57.0%) of 84 cases; whereas Xpert testing of morning specimens identified 50 (66.0%) of 76 cases. Two Xpert tests detected 22/24 (92.0%) TB cases with CD4 counts <100 cells/μL and 30/45 (67.0%) of cases with CD4 counts ≥100 cells/μl.

Conclusions

In PLHIV, Xpert substantially increased diagnostic yield compared to smear microscopy and had the highest yield when used to test morning specimens and specimens from PLHIV with CD4 count <100 cells/μL. TB programs unable to replace smear microscopy with Xpert for all symptomatic PLHIV should consider targeted replacement and using morning specimens.  相似文献   

13.

Background

Tuberculosis (TB) causes 1.45 million deaths annually world wide, the majority of which occur in the developing world. Active TB disease represents immune failure to control latent infection from airborne spread. Acid-fast bacillus (AFB) seen on sputum smear is a biomarker for contagiousness.

Methods

We enrolled 73 tuberculosis patients with extensive infiltrates into a research study using bronchoalveolar lavage (BAL) to sample lung immune cells and assay BAL cell cytokine production. All patients had sputum culture demonstrating Mycobacterium tuberculosis and 59/73 (81%) had AFB identified by microscopy of the sputum. Compared with smear negative patients, smear positive patients at presentation had a higher proportion with smoking history, a higher proportion with temperature >38.50 C, higher BAL cells/ml, lower percent lymphocytes in BAL, higher IL-4 and IL-12p40 in BAL cell supernatants. There was no correlation between AFB smear and other BAL or serum cytokines. Increasing IL-4 was associated with BAL PMN and negatively associated with BAL lymphocytes. Each 10-fold increase in BAL IL-4 and IL-12p40 increased the odds of AFB smear positivity by 7.4 and 2.2-fold, respectively, in a multi-variable logistic model.

Conclusion

Increasing IL-4 and IL-12p40 production by BAL cells are biomarkers for AFB in sputum of patients who present with radiographically advanced TB. They likely reflect less effective immune control of pathways for controlling TB, leading to patients with increased infectiousness.  相似文献   

14.

Introduction

To understand better the risk of tuberculosis transmission with increasing delay in tuberculosis treatment, we undertook a retrospective cohort study in Shenzhen, China.

Methods

All pulmonary tuberculosis cases in the Shenzhen tuberculosis surveillance database from 1993–2010 were included. Sputum smear positivity and presence of pulmonary cavity were used as proxies for risk of tuberculosis transmission.

Results

Among 48,441pulmonary tuberculosis cases, 70% presented with symptoms of pulmonary TB, 62% were sputum smear positive, and 21% had a pulmonary cavity on chest x-ray. 95.3% of patients self-presented for evaluation of illness after a median 58 days of delay after symptoms began. The proportion presenting sputum smear positive (p<0.001) and with a pulmonary cavity (p<0.001) increased significantly with increasing duration of delay.

Conclusions

Delayed diagnosis and treatment of tuberculosis is associated with a significantly increased risk of pulmonary sputum smear positivity and pulmonary cavity. To decrease risk of transmission, treatment delay needs to be reduced further.  相似文献   

15.

Background

Early and effective detection of Mycobacterium tuberculosis (MTB), particularly in smear-negative tuberculosis (TB), is a priority for global TB control. Loop-mediated isothermal amplification with a procedure for ultra rapid DNA extraction (PURE-LAMP) can detect TB in sputum samples rapidly and with high sensitivity and specificity. However, the PURE-LAMP test has not been effectively evaluated, especially in resource-limited laboratories. In this study, we evaluated the performance of the PURE-LAMP test for TB detection in TB suspects from two county-level TB dispensaries in China.

Methodology/Principal Findings

From April 2011 to February 2012, patients with suspected TB were continuously enrolled from two county-level TB laboratories in China. Three sputum samples (spot, night, and morning sputum) were collected from each recruited patient. Detection of MTB by PURE-LAMP was compared to a reference standard L-J culture. The results showed that the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection was 70.67%, while the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection in smear positive and culture positive patients and smear negative and culture positive patients was 92.12% and 53.81%, respectively. The specificity of PURE-LAMP based on spot sputum for MTB detection was 98.32%. The sensitivity and specificity of the PURE-LAMP test based on three sputa combination for MTB detection was 88.80% and 96.86%, respectively. The results also showed that the PURE-LAMP test had a significantly lower contamination rate than did solid culture.

Conclusions/Significance

The study suggested that, in peripheral-level TB laboratories in China, the PURE-LAMP test showed high sensitivity and specificity for TB detection in TB suspects, making it a more effective, rapid, and safe method worthy of broader use in the future.  相似文献   

16.

Introduction

The culture-negative conversion rate of sputum after 2 months of treatment in patients with pulmonary tuberculosis (TB) is used as a reliable surrogate marker for relapse after completion of treatment. We hypothesized that culture conversion of sputum at 2 months of anti-TB treatment and the time to culture conversion are different among pulmonary TB patients who are diagnosed using different methods.

Methods

Culture-confirmed pulmonary TB patients who were diagnosed between 1 January, 2011 and 31 December, 2012 were classified into three groups based on the diagnostic method that prompted treatment initiation: positive acid-fast bacilli (AFB) staining of sputum (smear-positive group), negative AFB staining, but Mycobacterium tuberculosis was cultured from sputum (culture-positive group), and positive AFB staining, positive polymerase chain reaction (PCR) for M. tuberculosis, or culture of M. tuberculosis from a bronchoscopic specimen (bronchoscopy group). Rates of negative mycobacterial culture conversion at 2 months of anti-TB treatment and the time to negative culture conversion of sputum were compared among the three groups.

Results

A total of 203 patients with culture-confirmed pulmonary TB were included in the final analysis. TB patients in the culture-positive group (94.1%) and the bronchoscopy group (97.6%) showed a higher culture conversion rate at 2 months of treatment than those in the smear-positive group (78.7%, P = 0.001). Additionally, the time to culture conversion was longer in the smear-positive group (median, 40 days) than in the culture-positive (median, 19 days; P = 0.009) and bronchoscopy groups (median, 29 days; P = 0.004).

Conclusions

The higher culture conversion rate at 2 months and the shorter time to culture conversion among pulmonary TB patients with a negative AFB smear suggests the feasibility of shortening treatment duration and isolation in these patients.  相似文献   

17.
18.

Background

Respiratory isolation of inpatients during evaluation for TB is a slow and costly process in low-burden settings. Xpert MTB/RIF (Xpert) is a novel molecular test for tuberculosis (TB) that is faster and more sensitive but substantially more expensive than smear microscopy. No previous studies have examined the costs of molecular testing as a replacement for smear microscopy in this setting.

Methods

We conducted an incremental cost–benefit analysis comparing the use of a single negative Xpert versus two negative sputum smears to release consecutive adult inpatients with presumed TB from respiratory isolation at an urban public hospital in the United States. We estimated all health-system costs and patient outcomes related to Xpert implementation, diagnostic evaluation, isolation, hospitalization, and treatment. We performed sensitivity and probabilistic uncertainty analyses to determine at what threshold the Xpert strategy would become cost-saving.

Results

Among a hypothetical cohort of 234 individuals undergoing evaluation for presumed active TB annually, 6.4% had culture-positive TB. Compared to smear microscopy, Xpert reduced isolation bed utilization from an average of 2.7 to 1.4 days per patient, leading to a 48% reduction in total annual isolation bed usage from 632 to 328 bed-days. Xpert saved an average of $2,278 (95% uncertainty range $1582–4570) per admission, or $533,520 per year, compared with smear microscopy.

Conclusions

Molecular testing for TB could provide substantial savings to hospitals in high-income countries by reducing respiratory isolation usage and overall length of stay.  相似文献   

19.

Background

In South Africa the estimated incidence of all forms of tuberculosis (TB) for 2008 was 960/100000. It was reported that all South Africans lived in districts with Directly Observed Therapy, Short-course. However, the 2011 WHO report indicated South Africa as the only country in the world where the TB incidence is still rising.

Aims

To report the results of a TB prevalence survey and to determine the speed of TB case detection in the study communities.

Methods

In 2005 a TB prevalence survey was done to inform the sample size calculation for the ZAMSTAR (Zambia South Africa TB and AIDS Reduction) trial. It was a cluster survey with clustering by enumeration area; all households were visited within enumeration areas and informed consent obtained from eligible adults. A questionnaire was completed and a sputum sample collected from each adult. Samples were inoculated on both liquid mycobacterium growth indicator tube (MGIT) and Löwenstein-Jensen media. A follow-up HIV prevalence survey was done in 2007.

Results

In Community A, the adjusted prevalence of culture positive TB was 32/1000 (95%CI 25–41/1000) and of smear positive TB 8/1000 (95%CI 5–13/1000). In Community B, the adjusted prevalence of culture positive TB was 24/1000 (95%CI 17–32/1000) and of smear positive TB 9/1000 (95%CI 6–15/1000). In Community A the patient diagnostic rate was 0.38/person-year while in community B it was 0.30/person-year. In both communities the adjusted HIV prevalence was 25% (19–30%).

Discussion

In both communities a higher TB prevalence than national estimates and a low patient diagnostic rate was calculated, suggesting that cases are not detected at a sufficient rate to interrupt transmission. These findings may contribute to the rising TB incidence in South Africa. The TB epidemic should therefore be addressed rapidly and effectively, especially in the presence of the concurrently high HIV prevalence.  相似文献   

20.
George G  Mony P  Kenneth J 《PloS one》2011,6(6):e21007

Background

Despite the advent of novel diagnostic techniques, smear microscopy remains as the most practical test available in resource-limited settings for tuberculosis (TB) diagnosis. Due to the low sensitivity of microscopy and the long time required for culture, feasible and accessible rapid diagnostic methods are urgently needed. Loop-mediated Isothermal Amplification (LAMP) is a promising nucleic-acid amplification assay, which could be accessible, cost-effective and more suited for use with unpurified samples.

Methodology/Principal Findings

In the current study, the objective was to assess the efficacy of a LAMP assay for tuberculosis compared with fluorescence smear microscopy as well as Löwenstein-Jensen (LJ) and Mycobacteria Growth Indicator Tube (MGIT) cultures for the diagnosis of pulmonary tuberculosis using sputum samples. Smear microscopy and culture were performed for decontaminated and concentrated sputum from TB suspects and the LAMP was also performed on these specimens. The LAMP and smear microscopy were compared, in series and in parallel, to culture. LAMP and smear microscopy showed sensitivities of 79.5% and 82.1% respectively and specificities of 93.8% and 96.9% respectively, compared to culture. LAMP and smear in series had sensitivity and specificity of 79.5% and 100.0% respectively. LAMP and smear in parallel had sensitivity and specificity of 82.1% and 90.6% respectively.

Conclusions/Significance

The overall efficacies of LAMP and fluorescence smear microscopy in the current study were high and broadly similar. LAMP and smear in series had high specificity (100.0%) and can be used as a rule-in test combination. However, the performance of LAMP in smear negative samples was found to be insufficient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏