首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Recent advances in mass spectrometry approaches to the analysis of lipids include the ability to incorporate both lipid class identification with lipid structural information for increased characterization capabilities. The detailed examination of lipids and their biosynthetic and biochemical pathways made possible by novel instrumental and bioinformatics approaches is advancing research in fundamental cellular and medical studies. Recently, high-throughput structural analysis has been demonstrated through the use of rapid gas-phase separation on the basis of the ion mobility (IM) analytical technique combined with mass spectrometry (IM-MS). While IM-MS has been extensively utilized in biochemical research for peptide, protein and small molecule analysis, the role of IM-MS in lipid research is still an active area of development. In this review of lipid-based IM-MS research, we begin with an overview of three contemporary IM techniques which show great promise in being applied towards the analysis of lipids. Fundamental concepts regarding the integration of IM-MS are reviewed with emphasis on the applications of IM-MS towards simplifying and enhancing complex biological sample analysis. Finally, several recent IM-MS lipid studies are highlighted and the future prospects of IM-MS for integrated omics studies and enhanced spatial profiling through imaging IM-MS are briefly described.  相似文献   

2.
Mass spectrometry has become an indispensable tool in identifying post-translationally modified proteins, but multiple peptide mass-mapping/peptide-sequencing experiments are required to answer questions involving the site and type of modification present. Here, we apply ion mobility-mass spectrometry (IM-MS), a high-throughput analysis method having high selectivity and sensitivity, to the challenge of identifying phosphorylated peptides. Ion mobility separation is based on the collision cross-section of the ion. Phosphorylation can result in a conformational change in gas-phase peptide ions, which can be detected by IM. To demonstrate this point, a peptide mixture containing a variety of peptide sequences is examined with IM-MS and molecular dynamics calculations. During the course of these studies, two classes of phosphopeptide were identified: (i) phosphorylated peptide ions that have conformers that differ from the nonphosphorylated ion and (ii) phosphorylated peptide ions that have conformations that are very similar to the nonphosphorylated peptide. The utility of IM-MS peptide mass mapping for identifying both types of phosphorylated peptides is discussed.  相似文献   

3.
The potential of drift tube ion mobility (IM) spectrometry in combination with high performance liquid chromatography (LC) and mass spectrometry (MS) for the metabonomic analysis of rat urine is reported. The combined LC-IM-MS approach using quadrupole/time-of-flight mass spectrometry with electrospray ionisation, uses gas-phase analyte characterisation based on both mass-to-charge (m/z) ratio and relative gas-phase mobility (drift time) following LC separation. The technique allowed the acquisition of nested data sets, with mass spectra acquired at regular intervals (65 micros) during each IMS separation (approximately 13 ms) and several IMS spectra acquired during the elution of a single LC peak, without increasing the overall analysis time compared to LC-MS. Preliminary results indicate that spectral quality is improved when using LC-IM-MS, compared to direct injection IM-MS, for which significant ion suppression effects were observed in the electrospray ion source. The use of reversed-phase LC employing fast gradient elution reduced sample preparation to a minimum, whilst maintaining the potential for high throughput analysis. Data mining allowed information on specific analytes to be extracted from the complex metabonomic data set. LC-IM-MS based approaches may have a useful role in metabonomic analyses by introducing an additional discriminatory dimension of ion mobility (drift time).  相似文献   

4.
Advances in the field of proteomics depend upon the development of high-throughput separation methods. Ion mobility-mass spectrometry is a fast separation method (separations on the millisecond time-scale), which has potential for peptide complex mixture analysis. Possible disadvantages of this technique center around the lack of orthogonality between separation based on ion mobility and separation based on mass. In order to examine the utility of ion mobility-mass spectrometry, the peak capacity (phi) of the technique was estimated by subjecting a large dataset of peptides to linear regression analysis to determine an average trend for tryptic peptides. This trend-line, along with the deviation from a linear relationship observed for this dataset, was used to define the separation space for ion mobility-mass spectrometry. Using the maximum deviation found in the dataset (+/-11%) the peak capacity of ion mobility-mass spectrometry is approximately 2600 peptides. These results are discussed in light of other factors that may increase the peak capacity of ion mobility-mass spectrometry (i.e. multiple trends in the data resulting from multiple classes of compounds present in a sample) and current liquid chromatography approaches to complex peptide mixture analysis.  相似文献   

5.
BackgroundDiverse varieties of often heterogeneous glycans are ubiquitous in nature. They play critical roles in recognition events, act as energy stores and provide structural stability at both molecular and cellular levels. Technologies capable of fully elucidating the structures of glycans are far behind the other ‘-omic’ fields. Liquid chromatography (LC) and mass spectrometry (MS) are currently the most useful techniques for high-throughput analysis of glycans. However, these techniques do not provide full unambiguous structural information and instead the gap in full sequence assignment is frequently filled by a priori knowledge of the biosynthetic pathways and the assumption that these pathways are highly conserved.Scope of the reviewThis comprehensive review details the rise of the emerging analytical technique ion mobility spectrometry (IMS) (coupled to MS) to facilitate the determination of three-dimensional shape: the separation and characterization of isobaric glycans, glyco(peptides/proteins), glycolipids, glycosaminoglycans and other polysaccharides; localization of sites of glycosylation; or interpretation of the conformational change to proteins upon glycan binding.Major conclusionsIMS is a highly promising new analytical route, able to provide rapid isomeric separation (ms timescale) of either precursor or product ions facilitating MS characterization. This additional separation also enables the deconvolution of carbohydrate MS(/MS) information from contaminating ions, improving sensitivity and reducing chemical noise. Derivation of collision cross sections (CCS) from IM-MS(/MS) data and subsequent calculations validate putative structures of carbohydrates from ab initio derived candidates. IM-MS has demonstrated that amounts of specific glycan isomers vary between disease states, which would be challenging to detect using standard analytical approaches.General significanceIM-MS is a promising technique that fills an important gap within the Glycomics toolbox, namely identifying and differentiating the three-dimensional structure of chemically similar carbohydrates and glycoconjugates. This article is part of a Special Issue entitled "Glycans in personalised medicine" Guest Editor: Professor Gordan Lauc.  相似文献   

6.
7.
Antibody–drug conjugates (ADCs) are biochemotherapeutics consisting of a cytotoxic chemical drug linked covalently to a monoclonal antibody. Two main classes of ADCs, namely cysteine and lysine conjugates, are currently available on the market or involved in clinical trials. The complex structure and heterogeneity of ADCs makes their biophysical characterization challenging. For cysteine conjugates, hydrophobic interaction chromatography is the gold standard technique for studying drug distribution, the naked antibody content, and the average drug to antibody ratio (DAR). For lysine ADC conjugates on the other hand, which are not amenable to hydrophobic interaction chromatography because of their higher heterogeneity, denaturing mass spectrometry (MS) and UV/Vis spectroscopy are the most powerful approaches. We report here the use of native MS and ion mobility (IM-MS) for the characterization of trastuzumab emtansine (T-DM1, Kadcyla®). This lysine conjugate is currently being considered for the treatment of human epidermal growth factor receptor 2 (HER2)-positive breast cancer, and combines the anti-HER2 antibody trastuzumab (Herceptin®), with the cytotoxic microtubule-inhibiting maytansine derivative, DM1. We show that native MS combined with high-resolution measurements and/or charge reduction is beneficial in terms of the accurate values it provides of the average DAR and the drug load profiles. The use of spectral deconvolution is discussed in detail. We report furthermore the use of native IM-MS to directly determine DAR distribution profiles and average DAR values, as well as a molecular modeling investigation of positional isomers in T-DM1.  相似文献   

8.
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.  相似文献   

9.
The development of a multidimensional approach involving high-performance liquid chromatography (LC), ion mobility spectrometry (IMS) and tandem mass spectrometry is described for the analysis of complex peptide mixtures. In this approach, peptides are separated based on differences in their LC retention times and mobilities (as ions drift through He) prior to being introduced into a quadrupole/octopole/time-of-flight mass spectrometer. The initial LC separation and IMS dispersion of ions is used to label ions for subsequent fragmentation studies that are carried out for mixtures of ions. The approach is demonstrated by examining a mixture of peptides generated from tryptic digestion of 18 commercially available proteins. Current limitations of this initial study and potential advantages of the experimental approach are discussed.  相似文献   

10.
Native mass spectrometry (MS) methods permit the study of multiple protein species within solution equilibria, whereas ion mobility (IM)-MS can report on conformational behavior of specific states. We used IM-MS to study a conformationally labile protein (α1-antitrypsin) that undergoes pathological polymerization in the context of point mutations. The folded, native state of the Z-variant remains highly polymerogenic in physiological conditions despite only minor thermodynamic destabilization relative to the wild-type variant. Various data implicate kinetic instability (conformational lability within a native state ensemble) as the basis of Z α1-antitrypsin polymerogenicity. We show the ability of IM-MS to track such disease-relevant conformational behavior in detail by studying the effects of peptide binding on α1-antitrypsin conformation and dynamics. IM-MS is, therefore, an ideal platform for the screening of compounds that result in therapeutically beneficial kinetic stabilization of native α1-antitrypsin. Our findings are confirmed with high-resolution X-ray crystallographic and nuclear magnetic resonance spectroscopic studies of the same event, which together dissect structural changes from dynamic effects caused by peptide binding at a residue-specific level. IM-MS methods, therefore, have great potential for further study of biologically relevant thermodynamic and kinetic instability of proteins and provide rapid and multidimensional characterization of ligand interactions of therapeutic interest.PDB Code(s): 4PYW  相似文献   

11.
The analytical scale of most mass‐spectrometry‐based targeted proteomics assays is usually limited by assay performance and instrument utilization. A recently introduced method, called triggered by offset, multiplexed, accurate mass, high resolution, and absolute quantitation (TOMAHAQ), combines both peptide and sample multiplexing to simultaneously improve analytical scale and quantitative performance. In the present work, critical technical requirements and data analysis considerations for successful implementation of the TOMAHAQ technique based on the study of a total of 185 target peptides across over 200 clinical plasma samples are discussed. Importantly, it is observed that significant interference originate from the TMTzero reporter ion used for the synthetic trigger peptides. This interference is not expected because only TMT10plex reporter ions from the target peptides should be observed under typical TOMAHAQ conditions. In order to unlock the great promise of the technique for high throughput quantification, here a post‐acquisition data correction strategy to deconvolute the reporter ion superposition and recover reliable data is proposed.  相似文献   

12.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve the detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, the authors review recent developments in LC-FAIMS-MS and its application to MS-based proteomics.  相似文献   

13.
Antibody-drug conjugates (ADCs) have emerged as a family of compounds with promise as efficient immunotherapies. First-generation ADCs were generated mostly via reactions on either lysine side-chain amines or cysteine thiol groups after reduction of the interchain disulfide bonds, resulting in heterogeneous populations with a variable number of drug loads per antibody. To control the position and the number of drug loads, new conjugation strategies aiming at the generation of more homogeneous site-specific conjugates have been developed. We report here the first multi-level characterization of a site-specific ADC by state-of-the-art mass spectrometry (MS) methods, including native MS and its hyphenation to ion mobility (IM-MS). We demonstrate the versatility of native MS methodologies for site-specific ADC analysis, with the unique ability to provide several critical quality attributes within one single run, along with a direct snapshot of ADC homogeneity/heterogeneity without extensive data interpretation. The capabilities of native IM-MS to directly access site-specific ADC conformational information are also highlighted. Finally, the potential of these techniques for assessing an ADC's heterogeneity/homogeneity is illustrated by comparing the analytical characterization of a site-specific DAR4 ADC to that of first-generation ADCs. Altogether, our results highlight the compatibility, versatility, and benefits of native MS approaches for the analytical characterization of all types of ADCs, including site-specific conjugates. Thus, we envision integrating native MS and IM-MS approaches, even in their latest state-of-the-art forms, into workflows that benchmark bioconjugation strategies.  相似文献   

14.
15.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that can be used to reduce sample complexity and increase dynamic range in tandem mass spectrometry experiments. FAIMS fractionates ions in the gas-phase according to characteristic differences in mobilities in electric fields of different strengths. Undesired ion species such as solvated clusters and singly charged chemical background ions can be prevented from reaching the mass analyzer, thus decreasing chemical noise. To date, there has been limited success using the commercially available Thermo Fisher FAIMS device with both standard ESI and nanoLC-MS. We have modified a Thermo Fisher electrospray source to accommodate a fused silica pulled tip capillary column for nanospray ionization, which will enable standard laboratories access to FAIMS technology. Our modified source allows easily obtainable stable spray at flow rates of 300 nL/min when coupled with FAIMS. The modified electrospray source allows the use of sheath gas, which provides a fivefold increase in signal obtained when nanoLC is coupled to FAIMS. In this work, nanoLC-FAIMS-MS and nanoLC-MS were compared by analyzing a tryptic digest of a 1:1 mixture of SILAC-labeled haploid and diploid yeast to demonstrate the performance of nanoLC-FAIMS-MS, at different compensation voltages, for post-column fractionation of complex protein digests. The effective dynamic range more than doubled when FAIMS was used. In total, 10,377 unique stripped peptides and 1649 unique proteins with SILAC ratios were identified from the combined nanoLC-FAIMS-MS experiments, compared with 6908 unique stripped peptides and 1003 unique proteins with SILAC ratios identified from the combined nanoLC-MS experiments. This work demonstrates how a commercially available FAIMS device can be combined with nanoLC to improve proteome coverage in shotgun and targeted type proteomics experiments.  相似文献   

16.
Element-coded affinity tags for peptides and proteins   总被引:2,自引:0,他引:2  
Isotope-coded affinity tags (ICAT) represent an important new tool for the analysis of complex mixtures of proteins in living systems [Aebersold, R., and Mann, M. (2003) Nature, 422, 198-207]. We envisage an alternative protein-labeling technique based on tagging with different element-coded metal chelates, which affords affinity chromatography, quantification, and identification of a tagged peptide from a complex mixture. As proof of concept, a synthetic peptide was modified at a cysteine side chain with either a carboxymethyl group or acetamidobenzyl-1,4,7,10-tetraazacyclododecane-N,N',N' ',N' "-tetraacetic acid (AcBD) chelates of terbium or yttrium. A mixture of the three modified peptides in a mole ratio of 100:1.0:0.83 carboxymethyl:AcBD-Tb:AcBD-Y was trypsinized, purified on a new affinity column that binds rare-earth DOTA chelates, and analyzed by LC-MS/MS. Chelate-tagged tryptic peptides eluted cleanly from the affinity column; the tagged peptides chromatographically coeluted during LC-MS analysis, were present in the expected ratio as indicated by MS ion intensity, and were sequence-identified by tandem mass spectrometry. DOTA-rare earth chelates have exceptional properties for use as affinity tags. They are highly polar and water-soluble. Many of the rare earth elements are naturally monoisotopic, providing a variety of simple choices for preparing mass tags. Further, the rare earths are heavy elements, whose mass defects give the masses of tagged peptides exact values not normally shared by molecules that contain only light elements.  相似文献   

17.
We discuss the theoretical and experimental potential and limitations of protein identification by mass measurement of proteolytic peptides and database searching. For peptides differing in composition by one (or two or three) amino acids, a surprisingly high number turn out to have isomers: 10% (or 29% or 53%), considering the 20 common amino acids with equal relative abundance. Even if isomers differing by leucine/isoleucine are excluded, the latter numbers are 14% and 38%--those isomeric peptides cannot be distinguished based on mass alone, and tandem mass spectrometry and/or other additional constraints are needed. However, for nominally isobaric peptides, the mass accuracy and resolving power of broadband Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry theoretically and experimentally suffice to resolve virtually all peptide doublets differing by up to two amino acids--including the smallest mass difference of 3.4 mDa. We demonstrate experimental resolution of another pair of peptides differing by 11 mDa, even when present in a complex mixture of hundreds of other peptides.  相似文献   

18.
Ihling C  Sinz A 《Proteomics》2005,5(8):2029-2042
The basic problem of complexity poses a significant challenge for proteomic studies. To date two-dimensional gel electrophoresis (2-DE) followed by enzymatic in-gel digestion of the peptides, and subsequent identification by mass spectrometry (MS) is the most commonly used method to analyze complex protein mixtures. However, 2-DE is a slow and labor-intensive technique, which is not able to resolve all proteins of a proteome. To overcome these limitations gel-free approaches are developed based on high performance liquid chromatography (HPLC) and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). The high resolution and excellent mass accuracy of FT-ICR MS provides a basis for simultaneous analysis of numerous compounds. In the present study, a small protein subfraction of an Escherichia coli cell lysate was prepared by size-exclusion chromatography and proteins were analyzed using C4 reversed phase (RP)-HPLC for pre-separation followed by C18 RP nanoHPLC/nanoESI FT-ICR MS for analysis of the peptide mixtures after tryptic digestion of the protein fractions. We identified 231 proteins and thus demonstrated that a combination of two RP separation steps - one on the protein and one on the peptide level - in combination with high-resolution FT-ICR MS has the potential to become a powerful method for global proteomics studies.  相似文献   

19.
Over the past decade peptide sequencing by collision induced dissociation (CID) has become the method of choice in mass spectrometry-based proteomics. The development of alternative fragmentation techniques such as electron transfer dissociation (ETD) has extended the possibilities within tandem mass spectrometry. Recent advances in instrumentation allow peptide fragment ions to be detected with high speed and sensitivity (e.g., in a 2D or 3D ion trap) or at high resolution and high mass accuracy (e.g., an Orbitrap or a ToF). Here, we describe a comprehensive experimental comparison of using ETD, ion-trap CID, and beam type CID (HCD) in combination with either linear ion trap or Orbitrap readout for the large-scale analysis of tryptic peptides. We investigate which combination of fragmentation technique and mass analyzer provides the best performance for the analysis of distinct peptide populations such as N-acetylated, phosphorylated, and tryptic peptides with up to two missed cleavages. We found that HCD provides more peptide identifications than CID and ETD for doubly charged peptides. In terms of Mascot score, ETD FT outperforms the other techniques for peptides with charge states higher than 2. Our data shows that there is a trade-off between spectral quality and speed when using the Orbitrap for fragment ion detection. We conclude that a decision-tree regulated combination of higher-energy collisional dissociation (HCD) and ETD can improve the average Mascot score.  相似文献   

20.
We have developed a novel procedure for concentrating sulfated peptides, as a front end to mass spectrometric analysis, based on ion-selective interaction of sulfate ions with anion exchangers. Ions with a higher charge and smaller solvated ion radius, such as sulfate ions, have higher retention in an ion exchanger due to their greater degree of coulombic interactions. We tested the effectiveness of this approach for enrichment and identification of sulfated peptides using a tryptic digest of bovine serum albumin spiked with model sulfated peptide (molar ratio 20:1) and using a tryptic digest of bovine fibrinogen. Sulfated peptides are identified by mass spectrometry in which both the molecular ion and its specific fragment ion produced by facile loss of SO(3) are detected. In both experiments, sulfated peptides were strongly retained on the anion exchanger and were eluted by higher concentrations of competing ion with minimal contamination of nonsulfated peptides. Using this procedure, we determined that the 13-amino acid C-terminal peptide of the minor gamma'-chain of bovine fibrinogen contains sulfated tyrosine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号