1.
Hérion  P.  Portetelle  D.  Franssen  J. -D.  Urbain  J.  Bollen  A. 《Bioscience reports》1983,3(4):381-388
Using two monoclonal antibodies directed against urokinase, we have developed a micro enzyme-linked immunosorbant assay (ELISA) to detect and measure urokinase in biological fluids. The system presents the following characteristics: simple and rapid procedure, reproducibility, sensitivity (urokinase levels down to 1 ng/ml) and evaluation of the enzyme in biological fluids such as urine, pleural effusions, and ascitic fluids without preliminary purification.  相似文献   

2.
Oleamide is a putative endogenous sleep-inducing lipid which potently enhances currents mediated by GABAA and serotonin receptors. While a quantitative assay would aid in determining the role of oleamide in physiological processes, most of the available assays are lacking in sensitivity. We now describe a quantitative assay for measuring low nanogram amounts of oleamide in biological fluids using GC/MS in the selective ion-monitoring mode. The internal standard (13C18 oleamide) was added to known concentrations of oleamide, which were converted to the N-trimethylsilyl or N-tert-butyldimethylsilyl derivatives before analysis by GC/MS, yielding linear calibration curves over the range of 1-25 ng of oleamide when monitoring the m/z 338/356 fragments. Using this technique, oleamide levels were determined following solvent extraction of normal rat cerebrospinal fluid and plasma to be 44 and 9.9 ng/ml, respectively. This technique constitutes a sensitive and reliable method for determining low nanogram quantities of oleamide in biological fluids.  相似文献   

3.
The platelet-derived growth factor (PDGF) is the principal mitogen in serum for cultured cells of mesenchymal origin. PDGF also is a potent chemotactic protein for inflammatory cells and for cells required for wound repair. Because activity levels of PDGF in biological fluids are difficult to measure, we attempted to develop a radioimmunoassay for PDGF. Rabbits were immunized with purified PDGF; the antiserum obtained was monospecific for PDGF in immunodiffusion analysis against concentrated platelet lysates, serum, and plasma. A radioimmunoassay for PDGF was developed with a sensitivity of congruent to 0.2 ng/ml. Levels of PDGF in plasma/serum were measured and compared with PDGF levels determined by a receptor-competition assay and by a standard biological assay measuring incorporation of [3H]thymidine into 3T3 cells. Radioimmunoassay showed apparent PDGF levels of 50 ng/ml in human plasma and 103 ng/ml in serum. The 50 ng/ml PDGF in plasma was unexpected because the plasma samples contained little or no platelet release products as determined by very low levels of platelet factor 4. We therefore sought an immunologically reactive PDGF molecule in human plasma. No immunologically reactive protein was detected by immunodiffusion analysis or when plasma was treated with an immunoaffinity gel. Subsequently, a 125I-PDGF-binding protein was identified; the 125I-PDGF-plasma-binding protein complex was not reactive with anti-PDGF immunoglobulin. Correction for 125I-PDGF bound by the plasma-binding protein established serum levels of PDGF of congruent to 50 ng/ml; congruent to 50 ng/ml PDGF was found in serum by radioreceptor-competition assays and by mitogenic assays as well. The plasma-binding protein may serve to clear PDGF released in the circulation, thereby limiting PDGF activity to its local interactions at the site of blood-vessel injury.  相似文献   

4.
Epidermal growth factor-like proteins in breast fluid and human milk   总被引:4,自引:0,他引:4  
J M Connolly  D P Rose 《Life sciences》1988,42(18):1751-1756
Epidermal growth factor (EGF), and the transforming growth factor-alpha (TGF-alpha) family of proteins, which also bind to the EGF receptor, have been associated with human breast cancer. The total EGF-like proteins were determined by a radioreceptor assay, and TGF-alpha by radioimmunoassay, in human milk and breast fluid samples. The breast fluids were collected by nipple aspiration from healthy premenopausal women. Both the 24 milks and 18 breast fluids assayed contained EGF-like proteins, at concentrations ranging from 32-600 ng/ml (median, 140 ng/ml), and 62-654 ng/ml (median, 205 ng/ml) respectively. Immunoreactive TGF-alpha proteins were detected at higher levels in 21 breast fluids (range, 0-50.0; median 5.1 ng/ml) than in 24 milk samples (range, 0-8.4; median, 0.8 ng/ml).  相似文献   

5.
A gas chromatographic–mass spectrometric (GC–MS) assay was developed for the quantitative analysis of methyl salicylate (MeS), ethyl salicylate (ES) and salicylic acid (SA) from biological fluids. The method was validated from 100-μl rat liver homogenate preparations (5 mg/ml protein) in 70 mM KH2PO4 (pH 7.4) buffer and from 100 μl rat plasma. The samples were extracted with chloroform, derivatized with BSTFA and quantitated by GC–MS in the SIM mode. The standard curves ranged from 31 ng/ml to 800 or 1250 ng/ml. Relative standard deviations and bias were less than 11% in plasma and homogenate for all compounds except SA which evidenced greater variability. The assay was used in preliminary experiments to characterize the pharmacokinetics of MeS in rats.  相似文献   

6.
A sensitive and selective gas chromatographic assay method employing splitless injection, fused-silica capillary columns and electron-capture detection is reported for the quantitation of the tocolytic drug, ritodrine, in a variety of biological fluids obtained from the pregnant ewe and fetus. This method has improved sensitivity and selectivity over previously published assay procedures. A 25 m × 0.31 mm I.D., cross-linked 5% phenylmethylsilicone, fused-silica capillary column was employed for all analyses. Linearity of response was observed over the range 2.5–75 ng of ritodrine base per 0.05–0.5 ml of biological fluid, representing ≈ 1–75 pg at the detector. The coefficient of variation was less than 10% over the range 2.5–75 ng of added ritodrine. The minimum quantifiable amounts is ≈ 2.5 ng from a 0.5-ml biological fluid sample. Applicability of this method to biological fluids, obtained from ovine subjects, is demonstrated by the analysis of samples obtained during the course of ritodrine placental transfer studies.  相似文献   

7.
Size heterogeneity of epidermal growth factor in human body fluids   总被引:2,自引:0,他引:2  
We measured the concentration of immunoreactive (IR) hEGF in various body fluids by radioimmunoassay (RIA) and evaluated its size heterogeneity by size exclusion high performance liquid chromatography combined with RIA or with time-resolved immunoflurometric assay (TR-IFMA). Mean concentration was 80 ng/ml in urine, 65 ng/ml in milk, 50 ng/ml in seminal plasma, 25 ng/ml in armpit sweat, 1 ng/ml in breast sweat, 0.3 ng/ml in third-trimester amniotic fluid, 3 ng/ml in saliva, 1.5 ng/ml in tears and 0.3 ng/ml in gastric juice.

All the fluids except armpit sweat and gastric juice contained two to five molecular sizes of IR-hEGF. As well as the 6200-dalton (6.2kDa) hEGF we found at least four other different molecular sizes with approximate weights of 300, 150, 70 and 20kDa. The authentic 6.2kDa form made up >90% of the total IR-hEGF in all except the amniotic fluid where its proportion was 71%, and the seminal plasma where the proportion could not be determined.  相似文献   


8.
We describe here a competitive hybridization assay using TRACE technology which can be used for real-time monitoring of oligonucleotide hybridization. This assay quantifies all kinds of oligonucleotides in biological fluids without extraction. The assay makes use of two different probes and involves a fluorescent transfer process. As fluorescence measurements are not destructive, they can be sequentially repeated, thereby allowing comparison of the hybridization kinetics and binding strength of chemically modified backbone oligonucleotides (>0.5 nM) in biological media. The assay was validated for pharmacokinetic analysis of phosphodiester and phosphorothioate oligonucleotides in plasma and in different organs (liver, kidneys, lungs, spleen) at low concentrations (0.4 mg/kg, corresponding to clinical doses). Respective sensitivities for phosphodiester and phosphorothioate were 0.2 and 0.8 pmol/ml in plasma and 2 and 8 pmol/g in tissues, which allow to recover intact phosphorothioate sequences in some organs even after 24 h.  相似文献   

9.
A modified gas chromatographic—mass spectrometric (GC—MS) assay has been developed to quantitate metoclopramide (MCP) and two of its metabolites [monodeethylated-MCP (mdMCP), dideethylated-MCP (ddMCP)] in the plasma, bile and urine of sheep. The heptafluorobutyryl derivatives of the compounds were formed and quantitated using electron-impact ionization in the selected-ion monitoring mode (MCP, m/z 86, 380; mdMCP, m/z 380 and ddMCP, m/z 380). No interference was observed from endogenous compounds following the extraction of various biological fluids obtained from non-pregnant sheep. Sample preparation has been simplified and the method is more selective and sensitive (2 fold) than our previous assay using electron-capture detection. The limit of quantitation for MCP, mdMCP and ddMCP was 1 ng/ml in plasma, urine and bile, requiring 0.5 ml of sample. This represents 2.5 pg of the analytes at the detector. The standard curves were linear over a working range of 1–40 ng/ml. Absolute recoveries in plasma ranged from 76.5–94.7%, 79.2–96.8%, 80.3–102.2% for MCP, mdMCP and ddMCP, respectively. In urine, recoveries ranged from 56.5–87.8%, 61.5–87.5%, 62.6–90.2% for MCP, mdMCP and ddMCP, respectively. Recoveries in bile ranged from 83.5–100.9%, 78.5–90.5%, 66.9–79.2% for MCP, mdMCP and ddMCP, respectively. Overall intra-day precision ranged from 2.9% for MCP in plasma to 12.6% for mdMCP in bile. Overall inter-day precision ranged from 5.9% for MCP in urine to 14.9% for ddMCP in bile. Bias was the greatest at the 1 ng/ml concentration in all biological fluids ranging from a low of 2.4% for mdMCP in plasma to a high of 11.9% for ddMCP in urine. Applicability of the assay for pharmacokinetic studies of MCP, mdMCP and ddMCP in the plasma and urine of a non-pregnant ewe is demonstrated.  相似文献   

10.
A new method, thermometric enzyme linked immunosorbent assay (TELISA), for the assay of endogenous and exogenous compounds in biological fluids is described. It is based on the previously described enzyme linked immunosorbent assay technique, ELISA, but utilizes enzymic heat formation which is measured in an enzyme thermistor unit. In the model system studied determination of human serum albumin down to a concentration of 10(-10) M (5 ng/ml) was achieved, with both normal and catalase labelled human serum albumin competing for the binding sites on the immunosorbent, which was rabbit antihuman serum albumin immobilized onto Sepharose CL-4B.  相似文献   

11.
A direct plasma injection method has been developed for the rapid analysis of drugs in biological fluids. A new generation restricted access media column specifically designed to accommodate direct injection of plasma and other fluids is utilized for on-line HPLC–ESI-MS analysis. For rapid analysis the on-line extraction column is linked to a HPLC–ESI-MS system. Good results are obtained for the quantitation of CP-93 393 and deuterated internal standard over the range of 10–1000 ng/ml. The lower limit of detection for the assay was 58 pg injected on column. Accuracy and precision values are 9.0% or better over the entire range of the assay. In addition, more than 200 injections (100 μl) were performed per column with unattended, automated analysis.  相似文献   

12.
A two-site enzyme immunoassay for lipocortin 1 (LC1) has been developed. The detection limit of LC1 was 0.2 ng/tube and the optimal assay range was 1 to 100 ng/tube. The assay system enabled us to identify immunoreactive lipocortin 1-like molecules (IR-LC1) in human serum and plasma. Normal human serum and plasma IR-LC1 concentrations were 44.6 ng/ml for males and 43.1 ng/ml for females with no significant difference between both sexes. The age-related analysis among nine age groups from newborn to 69 years old revealed that the serum or plasma level was high in infants (77.5 ng/ml for newborn and 75.6 ng/ml for 1 month-1 year group), and the 40-year-old (52.2 ng/ml) and 50-year-old (51.3 ng/ml) groups. The major population of plasma IR-LC1 was of 70 kDa in size corresponding to that of the LC1 homodimer. The present enzyme immunoassay system is sufficiently sensitive for the clinical study of LC1 in human body fluids, tissues and organs.  相似文献   

13.
A solid-phase radioimmunoassay for measuring neutrophil elastase in the range 0.08-4 ng/ml has been developed. A monospecific, precipitating antibody capable of inhibiting elastinolysis was produced by repeated immunizations of a goat. The IgG fraction and affinity-purified antibodies of this serum were then obtained and used to develop this radioimmunoassay. There was no cross-reactivity in binding of the radiolabeled antisera with lactoferrin, cathepsin G, or serine proteinases with amino-terminal amino acid sequence homology. Although serum influences the measurement of catalytically active neutrophil elastase when compared to diisopropylfluorophosphate-treated neutrophil elastase, antigenic elastase may still be measured in body fluids. Furthermore, this assay is more sensitive than commercially available substrates used for quantitating neutrophil elastase by functional activity. We have found this quantitative assay extremely useful in balance studies to measure secreted and cell-associated elastase and in screening of biological fluids for the presence of the enzyme.  相似文献   

14.
The development of the HIV protease inhibitor saquinavir (Ro 31-8959) required a range of analytical methods for its measurement in biological fluids. This paper describes the development of isocratic, reverse-phase HPLC/UV methods for the routine measurement of plasma levels of the drug together with a more sensitive radioimmunoassay. The performance of the two assays is compared with that of an HPLC/MS/MS method previously published and has been shown to be satisfactory, with coefficients of variation of calibration standards and quality control samples within the usual outside limits of +/- 15%. The HPLC/UV method can be routinely applied for concentrations down to 10-20 ng/ml and a lower limit of quantification of 1 ng/ml from 1 ml of human plasma is possible. The radioimmunoassay was developed for the specific measurement of saquinavir concentrations in human, HIV-positive plasma samples and has a lower limit of quantification of 0.5-1.0 ng/ml. Some preliminary findings suggested that it might not be specific in rat plasma and no attempts have been made to quantify any nonclinical samples with this technique. If still greater sensitivity is required, recourse can be made to the HPLC/MS/MS assay.  相似文献   

15.
Two enzyme-linked immunosorbent assays (ELISAs) have been developed for the quantification of soluble human glial fibrillary acidic protein (GFAP). The specificity of the assays for GFAP is ensured by the use of a monoclonal antibody directed against a GFAP-specific antigenic determinant. One ELISA is a four-layer system working in the concentration range 5-600 ng GFAP/ml. The other ELISA is a five-layer system and includes a biotin/avidin binding reaction. The latter assay has a working range of 0.5-60 ng GFAP/ml. The assays may be used for quantification of GFAP in CSFs, amniotic fluids, and extracts or homogenates of normal and pathological brain material. GFAP in serum could not be quantified because of unidentified interference. CSFs from 18 nonneurological subjects were found to contain 2-14 ng GFAP/ml (mean 4.1 ng/ml), whereas amniotic fluids from 50 normal pregnant women contained up to 24 ng GFAP/ml (mean 12.4 ng/ml). GFAP concentrations in CSFs from 32 multiple sclerosis patients were found not to be elevated compared to the control group.  相似文献   

16.
High sensitivity immunoassays using particulate fluorescent labels.   总被引:7,自引:0,他引:7  
The use of polystyrene fluorescent microspheres as sensitive labels in direct-detection (not enzymatically amplified) heterogeneous equilibrium "sandwich" immunoassays in 96-well plates is described. With mouse IgG as a model antigen, a fluorescent particulate label is more sensitive than a corresponding soluble reporter. The limit of detection of mouse IgG in the multiparametrically optimized assay was 0.2 ng/ml (7.6 x 10(8) antigens/ml) for the particulate reporter and 50 ng/ml (1.9 x 10(11) antigens/ml) for the soluble reporter. The sensitivities of assays using the particulate label were dependent on the surface densities of the capture and reporter antibodies and the concentration of reporter beads. Sensitivity was improved by adding the preformed reporter antibody/fluorescent microsphere complex to trapped antigen on the well surfaces instead of sequentially adding the reporter antibody and then the fluorescent microspheres. Maximal (equilibrium) binding of the particulate reporter to captured antigen occurred after 20 h with a concentration of 1.4 x 10(9) reporter beads/ml. Thus, particulate fluorescent labels provide high sensitivity in direct-detection immunoassays.  相似文献   

17.
Mianserin is a tetracyclic antidepressant drug and administered as racemate of R (-) and S (+) mianserin hydrochloride in a dose of 30-90 mg/day in divided doses. Liquid chromatography-mass spectroscopy (LC-MS) is a tool, which is widely used for determination of drug and their metabolites in biological fluids because of its high sensitivity and precision. Here we describe a liquid chromatography mass spectroscopy method for simultaneous determination of mianserin and its metabolite, N-desmethylmianserin, from human plasma using a liquid-liquid extraction with hexane:isoamylalcohol (98:2) and back extraction with 0.005 M formic acid solution. This method is specific and linear over the concentration range of 1.00-60.00 ng/ml for mianserin and 0.50-14.00 ng/ml for N-desmethylmianserin in human plasma. The lowest limits of quantification (LLQ) is 1.00 ng/ml for mianserin and 0.50 ng/ml for N-desmethylmianserin. Intraday and interday precision (%C.V.) is <10% for both mianserin and N-desmethylmianserin. The accuracy ranges from 94.44 to 112.33% for mianserin and 91.85-100.13% for N-desmethylmianserin. The stability studies showed that mianserin and N-desmethylmianserin in human plasma are stable during short-term period for sample preparation and analysis. The method was used to assay mianserin and its metabolite, N-desmethylmianserin, in human plasma samples obtained from subjects who had been given an oral tablet of 30 mg of mianserin.  相似文献   

18.
The development of an immunochromatographic technique suitable for rapid analysis of biological fluids is described. Quasi-one-dimensional antibody lattices specific for theophylline were constructed by packing Sepharose beads conjugated with specific antibody into specially designed narrow capillary tubes. The design of these capillary columns was such that they would subtract a preset threshold quantity of antigen (label and analyte) from the total amount presented. Labeled antigen, which appeared in the flowthrough, could then be used to precisely quantitate the analyte present. The ideal format would permit very precise subtraction of 100% of the available antigen up to the threshold amount and none of the remainder. The microcolumn described here comes close to this ideal behavior through the attainment of very high ratios of bound/free antigen. The elevated bound/free ratio could be explained by theoretical analysis of the effect on equilibria of the high antibody concentration in this quasi-one-dimensional system. Lattices containing anti-theophylline antibodies were used to develop a competitive enzyme immunoassay for theophylline which demonstrated a dose-response that was closely similar to that predicted by theoretical treatment. The entire assay procedure was performed in less than 30 min and demonstrated a sensitivity limit of approximately 20 ng/ml. Preliminary studies on clinical serum samples suggest that this assay has potential for the routine analysis of biological fluids.  相似文献   

19.
The sensitivity limits for an in-line interferometric (IL)/fluorescent (FL) dual-channel BioCD are established as a function of spatial averaging. Forward-phase and sandwich assays at 10ng/ml were performed on large-scale antibody microarrays (6800-spot) and detected using in-line interferometry and fluorescence channels. The interferometric channel has an extrapolated label-free limit-of-detection (LOD) of 250pg/ml in a forward-phase assay for which the fluorescent channel is inapplicable. In the sandwich assay, the extrapolated limit-of-detection is 70pg/ml for the interferometric channel, and for the fluorescent channel it is 30pg/ml. Intrinsic scale-free sensitivities for the detection channels are defined assuming spatially uncorrelated fluctuations with sensitivities of S'=13pg/mm for interferometric detection and 7pg/mm for sandwich fluorescent detection. The intrinsic sensitivities become weakly scale dependent in the presence of fractal spatial correlations among the antibody spots.  相似文献   

20.
A method for the quantitative determination of chlorpromazine and five of its major metabolites in a single sample of biological fluid in the ng/ml range has been developed utilizing gas chromatography/mass spectrometry with selected ion recording. The assay is highly specific and quantification is accomplished by an inverse stable isotope dilution technique, using deuterium-labeled variants of the compounds as internal standards. In this way the concentrations of chlorpromazine and five of its major metabolites (the sulfoxide, the N-oxide, the monodemethylated, the didemethylated, and the 7-hydroxylated compounds) can be determined in biological fluids. Levels in humans have been measured both in plasma and in red blood cells and are compared to those found in related in vitro studies.  相似文献   