1.

Purpose

Although the lamina cribrosa (LC) is the primary site of axonal damage in glaucoma, adequate methods to image and measure it are currently lacking. Here, we describe a noninvasive, in vivo method of evaluating the LC, based on swept-source optical coherence tomography (SS-OCT), and determine this method’s ability to quantify LC thickness.

Methods

This study comprised 54 eyes, including normal (n = 18), preperimetric glaucoma (PPG; n = 18), and normal tension glaucoma (NTG; n = 18) eyes. We used SS-OCT to obtain 3 x 3 mm cube scans of an area centered on the optic disc, and then synchronized reconstructed B- and en-face images from this data. We identified the LC in these B-scan images by marking the visible borders of the LC pores. We marked points on the anterior and posterior borders of the LC in 12 B-scan images in order to create a skeleton model of the LC. Finally, we used B-spline interpolation to form a 3D model of the LC, including only reliably measured scan areas. We calculated the average LC thickness (avgLCT) in this model and used Spearman''s rank correlation coefficient to compare it with circumpapillary retinal nerve fiber layer thickness (cpRNFLT).

Results

We found that the correlation coefficient of avgLCT and cpRNFLT was 0.64 (p < 0.01). The coefficient of variation for avgLCT was 5.1%. AvgLCT differed significantly in the groups (normal: 282.6 ± 20.6 μm, PPG: 261.4 ± 15.8 μm, NTG: 232.6 ± 33.3 μm). The normal, PPG and NTG groups did not significantly differ in age, sex, refractive error or intraocular pressure (IOP), although the normal and NTG groups differed significantly in cpRNFLT and Humphrey field analyzer measurements of mean deviation.

Conclusion

Thus, our results indicate that the parameters of our newly developed method of measuring LC thickness with SS-OCT may provide useful and important data for glaucoma diagnosis and research.  相似文献   

2.
PurposeTo investigate the influence of various risk factors on thinning of the lamina cribrosa (LC), as measured with swept-source optical coherence tomography (SS-OCT; Topcon).MethodsThis retrospective study comprised 150 eyes of 150 patients: 22 normal subjects, 28 preperimetric glaucoma (PPG) patients, and 100 open-angle glaucoma patients. Average LC thickness was determined in a 3 x 3 mm cube scan of the optic disc, over which a 4 x 4 grid of 16 points was superimposed (interpoint distance: 175 μm), centered on the circular Bruch’s membrane opening. The borders of the LC were defined as the visible limits of the LC pores. The correlation of LC thickness with Humphrey field analyzer-measured mean deviation (MD; SITA standard 24–2), circumpapillary retinal nerve fiber layer thickness (cpRNFLT), the vertical cup-to-disc (C/D) ratio, and tissue mean blur rate (MBR) was determined with Spearman''s rank correlation coefficient. The relationship of LC thickness with age, axial length, intraocular pressure (IOP), MD, the vertical C/D ratio, central corneal thickness (CCT), and tissue MBR was determined with multiple regression analysis. Average LC thickness and the correlation between LC thickness and MD were compared in patients with the glaucomatous enlargement (GE) optic disc type and those with non-GE disc types, as classified with Nicolela’s method.ResultsWe found that average LC thickness in the 16 grid points was significantly associated with overall LC thickness (r = 0.77, P < 0.001). The measurement time for this area was 12.4 ± 2.4 minutes. Average LC thickness in this area had a correlation coefficient of 0.57 with cpRNFLT (P < 0.001) and 0.46 (P < 0.001) with MD. Average LC thickness differed significantly between the groups (normal: 268 ± 23 μm, PPG: 248 ± 13 μm, OAG: 233 ± 20 μm). Multiple regression analysis showed that MD (β = 0.29, P = 0.013), vertical C/D ratio (β = -0.25, P = 0.020) and tissue MBR (β = 0.20, P = 0.034) were independent variables significantly affecting LC thickness, but age, axial length, IOP, and CCT were not. LC thickness was significantly lower in the GE patients (233.9 ± 17.3 μm) than the non-GE patients (243.6 ± 19.5 μm, P = 0.040). The correlation coefficient between MD and LC thickness was 0.58 (P < 0.001) in the GE patients and 0.39 (P = 0.013) in the non-GE patients.ConclusionCupping formation and tissue blood flow were independently correlated to LC thinning. Glaucoma patients with the GE disc type, who predominantly have large cupping, had lower LC thickness even with similar glaucoma severity.  相似文献   

3.

Purpose

To compare the abilities of spectral-domain optical coherence tomography (OCT) (SD-OCT; Spectralis, Heidelberg Engineering) and swept-source OCT (SS-OCT; DRI-OCT1 Atlantis system, Topcon) for analyzing the macular inner retinal layers in diagnosing glaucoma.

Methods

The study included 60 patients with primary open-angle glaucoma (POAG) and 60 healthy control subjects. Macular cube area was scanned using SD-OCT and SS-OCT on the same day to assess the thicknesses of the macular retinal nerve fiber layer (mRNFL), ganglion cell layer plus inner plexiform layer (GCIPL), and total retinal layer in nine subfields defined by the Early Treatment Diabetic Retinopathy Study (ETDRS). The abilities of the parameters to discriminate between the POAG and control groups were assessed using areas under the receiver operating characteristic curves (AUCs).

Results

Glaucoma-associated mRNFL and GCIPL thinning was more common in the outer zones than inner zones for both SD-OCT and SS-OCT. The mRNFL and GCIPL measurements showed distinct pattern differences between SD-OCT and SS-OCT in each ETDRS subfield. Although the glaucoma-diagnosis ability was comparable between SD-OCT and SS-OCT for most of the parameters, AUC was significantly larger for SD-OCT measurements of the GCIPL thickness in the outer temporal zones (p = 0.003) and of the mRNFL thickness in the outer nasal zones (p = 0.001), with the former having the largest AUC for discriminating POAG from healthy eyes (AUC = 0.894).

Conclusion

Spectralis SD-OCT and DRI SS-OCT have similar glaucoma-diagnosis abilities based on macular inner layer thickness analysis. However, Spectralis SD-OCT was potentially superior to DRI SS-OCT in detecting GCIPL thinning in the outer temporal zone, where the glaucomatous damage predominantly occurs.  相似文献   

4.
This study was designed to evaluate iVue Spectral-domain optical coherence tomography (SD-OCT) effectiveness in screening for eye disease compared to clinical examination. Subjects were recruited from the Casey Eye Community Outreach Program Mobile Clinic during its routinely scheduled outreach clinics to indigent, underserved populations throughout Oregon. Macular optical coherence tomography interpretation and automated optical coherence tomography analysis were compared to the clinical examination, with specific attention to findings indicative of retinal abnormalities, risks for glaucoma, and narrow angles. As a result, a total of 114 subjects were included in this study. In diabetics, optical coherence tomography and clinical exam were in fair agreement (kappa = 0.39), with 22% of eyes having abnormal findings on macular optical coherence tomography and 26% of eyes having diabetic retinopathy or diabetic macular edema on fundus exam. In non-diabetics, optical coherence tomography and clinical exam were in fair agreement (kappa = 0.28), with 11% of eyes having abnormal findings on macular optical coherence tomography and 9% on fundus exam. Using optical coherence tomography ganglion cell complex and retinal nerve fiber layer analysis, 18% of eyes were found to be glaucoma suspects, whereas clinical exam of cup-to-disc ratio detected 8% and intraocular pressure 5%. Agreements between optical coherence tomography and other methods were poor (kappa < 0.11) for glaucoma suspect. Anterior segment optical coherence tomography of the angle found 8% of eyes to have occludable angles, whereas slit lamp and gonioscopy found 5% of eyes to have narrow angles, with moderate agreement (kappa = 0.57). In summary, optical coherence tomography detected additional retinal abnormalities, glaucoma suspects, and narrow angles compared to clinical exam alone and may serve as a useful adjunct to the clinical exam in screening for eye disease in a low-risk, medically underserved, ethnically diverse population.  相似文献   

5.

Purpose

To assess the correlation and agreement between the Topcon built-in algorithm and our graph-based algorithm in measuring the total and regional macular thickness for normal and glaucoma subjects.

Methods

A total of 228 normal eyes and 93 glaucomatous eyes were enrolled in our study. All patients underwent comprehensive ophthalmic examination and Topcon 3D-OCT 2000 scan. One eye was randomly selected for each subject. The thickness of each layer and the total and regional macular thickness on an Early Treatment of Diabetic Retinopathy Study (ETDRS) chart were measured using the Topcon algorithm and our three-dimensional graph-based algorithm. Correlation and agreement analyses between these two algorithms were performed.

Results

Our graph search algorithm exhibited a strong correlation with Topcon algorithm. The macular GCC thickness values for normal and glaucoma subjects ranged from 0.86 to 0.91 and from 0.78 to 0.90, and the regional macular thickness values ranged from 0.79 to 0.96 and 0.70 to 0.95, respectively. Small differences were observed between the Topcon algorithm and our graph-based algorithm. The span of 95% limits of agreement of macular GCC thickness was less than 28 μm in both normal and glaucoma subjects, respectively. These limits of total and regional macular thickness were 15.5 μm and 23.1 μm for normal subjects and 29.1 μm and 46.4 μm for glaucoma subjects, respectively.

Conclusion

Our graph-based algorithm exhibited a high degree of agreement with the Topcon algorithm with respect to thickness measurements in normal and glaucoma subjects. Moreover, our graph-based algorithm can segment the retina into more layers than the Topcon algorithm does.  相似文献   

6.
BackgroundGlaucoma is the leading cause of irreversible blindness worldwide and primary open-angle glaucoma (POAG) is the most common type of glaucoma. An association between POAG and the subsequent risk of Alzheimer''s disease (AD) and Parkinson''s disease (PD) was unclear.ObjectiveTo investigate the association between POAG (including normal-tension glaucoma) and the subsequent risk of AD or PD 8 years following a diagnosis of POAG.MethodsWe performed a retrospective, propensity-score-matched analysis of a population-based cohort consisting of patients with and without POAG aged 60 years and older. Control patients without POAG were propensity-score matched to POAG patients based on their baseline characteristics.ResultsThe incidence rates and confidence intervals (CIs) of AD among the patients with and without POAG were 2.85 (95% CI: 2.19–3.70) and 1.98 (95% CI: 1.68–2.31) per 1000 person-years, respectively. The incidence rates of PD among the POAG and non-POAG cohorts were 4.36 (95% CI: 3.52–5.39) and 4.37 (95% CI: 3.92–4.86) per 1000 person-years, respectively. Kaplan-Meier failure curves showed that the POAG patients had a higher risk of AD than the control patients did (log-rank test, P = .0189). However, the cumulative PD hazard ratios for the POAG and non-POAG patients did not differ significantly (log-rank test, P = .9953).ConclusionIn elderly patients, POAG is a significant predictor of AD, but POAG is not a predictor of PD.  相似文献   

7.

Purpose

To diagnose glaucoma based on spectral domain optical coherence tomography (SD-OCT) measurements using the ‘Random Forests’ method.

Methods

SD-OCT was conducted in 126 eyes of 126 open angle glaucoma (OAG) patients and 84 eyes of 84 normal subjects. The Random Forests method was then applied to discriminate between glaucoma and normal eyes using 151 OCT parameters including thickness measurements of circumpapillary retinal nerve fiber layer (cpRNFL), the macular RNFL (mRNFL) and the ganglion cell layer-inner plexiform layer combined (GCIPL). The area under the receiver operating characteristic curve (AROC) was calculated using the Random Forests method adopting leave-one-out cross validation. For comparison, AROCs were calculated based on each one of the 151 OCT parameters.

Results

The AROC obtained with the Random Forests method was 98.5% [95% Confidence interval (CI): 97.1–99.9%], which was significantly larger than the AROCs derived from any single OCT parameter (maxima were: 92.8 [CI: 89.4–96.2] %, 94.3 [CI: 91.1–97.6] % and 91.8 [CI: 88.2–95.4] % for cpRNFL-, mRNFL- and GCIPL-related parameters, respectively; P<0.05, DeLong’s method with Holm’s correction for multiple comparisons). The partial AROC above specificity of 80%, for the Random Forests method was equal to 18.5 [CI: 16.8–19.6] %, which was also significantly larger than the AROCs of any single OCT parameter (P<0.05, Bootstrap method with Holm’s correction for multiple comparisons).

Conclusions

The Random Forests method, analyzing multiple SD-OCT parameters concurrently, significantly improves the diagnosis of glaucoma compared with using any single SD-OCT measurement.  相似文献   

8.

Purpose

To evaluate choroidal thickness (CT) in healthy and glaucomatous eyes using Swept Source Optical Coherence Tomography (SS-OCT).

Methods

A cross-sectional observational study of 216 eyes of 140 subjects with glaucoma and 106 eyes of 67 healthy subjects enrolled in the Diagnostic Innovations in Glaucoma Study. CT was assessed from wide-field (12×9 mm) SS-OCT scans. The association between CT and potential confounding variables including age, gender, axial length, intraocular pressure, central corneal thickness and ocular perfusion pressure was examined using univariable and multivariable regression analyses.

Results

Overall CT was thinner in glaucomatous eyes with a mean (± standard deviation) of 157.7±48.5 µm in glaucoma compared to 179.9±36.1 µm in healthy eyes (P<0.001). The choroid was thinner in both the peripapillary and macular regions in glaucoma compared to controls. Mean peripapillary CT was 154.1±44.1 µm and 134.0±56.9 µm (P<0.001) and macular CT 199.3±46.1 µm and 176.2±57.5 µm (P<0.001) for healthy and glaucomatous eyes respectively. However, older age (P<0.001) and longer axial length (P<0.001) were also associated with thinner choroid and when differences in age and axial length between glaucomatous and healthy subjects were accounted for, glaucoma was not significantly associated with CT. There was also no association between glaucoma severity and CT.

Conclusions

Glaucoma was not associated with CT measured using SS-OCT; however, older age and longer axial length were associated with thinner choroid so should be considered when interpreting CT measurements.  相似文献   

9.

Purpose

To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT).

Methods

Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter.

Results

The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively.

Conclusions

Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters.  相似文献   

10.

Purpose

Quantitative evaluation of lamina cribrosa (LC) posterior bowing in primary open-angle glaucoma (POAG) eyes using swept-source optical coherence tomography.

Methods

Patients with POAG (n = 123 eyes) and healthy individuals of a similar age (n = 92 eyes) were prospectively recruited. Anterior laminar insertion depth (ALID) was defined as the vertical distance between the anterior laminar insertion and a reference plane connecting the Bruch’s membrane openings (BMO). The mean LC depth (mLCD) was approximated by dividing the area enclosed by the anterior LC, the BMO reference plane, and the two vertical lines for ALID measurement by the length between those two vertical lines. The LC curvature index was defined as the difference between the mLCD and the ALID. The factors influencing the LC curvature index were evaluated.

Results

The ALID and mLCD were significantly larger in POAG eyes than in healthy controls (P < 0.05). The LC curvature index was significantly larger in POAG eyes than in healthy controls on both the horizontal (85.8 ± 34.1 vs. 68.2 ± 32.3 μm) and vertical meridians (49.8 ± 38.5 vs. 32.2 ± 31.1 μm, all P < 0.001). Multivariate regression showed significant associations of greater disc area (P < 0.001), vertical C/D ratio (P < 0.001) and mLCD (P < 0.001), smaller rim area (P = 0.001), thinner average RNFLT (P < 0.001), and myopic refraction (P = 0.049) with increased LC curvature index. There was no difference in the LC curvature index between mild (MD > –6 dB) and moderate-to-advanced glaucoma (MD < –6 dB, P = 0.95).

Conclusions

LC posterior bowing was increased in POAG eyes, and was significantly associated with structural optic nerve head (ONH) changes but not with functional glaucoma severity. Quantitative evaluation of LC curvature can facilitate assessment of glaucomatous ONH change.  相似文献   

11.

Purpose

This study was conducted in order to compare relationships between the macular visual field (VF) mean sensitivity measured by MAIATM (Macular Integrity Assessment), MP-3, or Humphry field analyzer (HFA) and the ganglion cell and inner plexiform layer (GCA) thicknesses.

Methods

This cross-sectional study examined 73 glaucoma patients and 19 normal subjects. All subjects underwent measurements for GCA thickness by Cirrus HD-OCT and static threshold perimetry using MAIATM, MP-3, or HFA. VF and OCT in the retinal view were used to examine both the global relationship between the VF sensitivity and GCA thickness, and the superior hemiretina and inferior hemiretina. The relationship between the GCA thickness and macular sensitivity was examined by Spearman correlation analysis.

Results

For each instrument, statistically significant macular VF sensitivity (dB) and GCA thickness relationships were observed using the decibel scale (R = 0.547–0.687, all P < 0.001). The highest correlation for the global (R = 0.682) and the superior hemiretina (R = 0.594) GCA thickness-VF mean sensitivity was observed by the HFA. The highest correlation for the inferior hemiretina (R = 0.687) GCA thickness-VF mean sensitivity was observed by the MP-3. Among the three VF measurement instruments, however, no significant differences were found for the structure-function relationships.

Conclusions

All three VF measurement instruments found similar structure-function relationships in the central VF.  相似文献   

12.

Objective

To investigate the 5-year incidence and progression rate of primary open-angle glaucoma (POAG) in a health-center-based Korean population.

Methods

The study population comprised 5,021 subjects who participated in standardized health screening (including non-contact tonometry and fundus photography) at the Gangnam Healthcare Center during the period from January 2005 to December 2006 and again from January 2010 to December 2011. Among these subjects, 948 (18.9%) with findings suggestive of glaucoma were subjected to a comprehensive glaucoma evaluation, which included applanation tonometry and standard automated perimetry. Based on the results, the subjects were diagnosed as POAG suspect or definite POAG.

Results

The 5-year incidences of POAG suspect and definite POAG were 0.84% (42 subjects) and 0.72% (36 subjects), respectively. The rate of progression from POAG suspect to definite POAG was 4.75% per year. In subjects with a baseline intraocular pressure (IOP) >21 mmHg, the incidence of POAG suspect or definite POAG was significantly higher than in those with a baseline IOP≤21 mmHg (32% vs. 1.05%; P<0.001). A multivariate analysis showed that the progression from POAG suspect to definite POAG was significantly associated with older age (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.03–1.10), higher baseline IOP (OR, 1.10; 95% CI, 1.01–1.24), higher body mass index (BMI) (OR, 1.15; 95% CI, 1.03–1.31), higher education level (OR, 1.57; 95% CI, 1.05–2.17), and higher hematocrit level (OR, 1.22; 95% CI, 1.08–1.43).

Conclusions

In the health-center-based Korean population, the 5-year incidence of POAG was 0.72%, and the rate of progression from POAG suspect to definite POAG was 4.75% per year. This study identified old age, high baseline IOP, high BMI, high level of education, and high hematocrit level as significant risk factors for incident POAG.  相似文献   

13.

Purpose

To compare the reproducibility of SD-OCT (spectral-domain optical coherence tomography) measurements of RNFL (retinal nerve fiber layer) and macular thickness between children and adults.

Methods

Seventy-one eyes of 71 children and 71 eyes of 71 adults were prospectively enrolled. RNFL and macular thicknesses were measured by one operator, with a brief rest between measurements. The two measurements were obtained using the eye tracking and retest function of Spectralis SD-OCT. Reproducibility was evaluated with reference to COVs (coefficients of variation) and ICCs (intraclass correlation coefficients). The ICC values of the RNFL and macular thicknesses were compared, respectively between the two groups, by Fisher’s z-test.

Results

The RNFL and macular thicknesses did not differ between the two groups. The COVs of the RNFL measurements ranged from 0.945 to 4.531% in the children group and from 0.496 to 1.391% in the adults group. In most of the RNFL sectors, the ICCs of the children group (range: 0.731–0.987) were significantly lower than those of the adults group (range: 0.986–0.993). The COVs of the macular measurements ranged from 0.496 to 1.157% in the children group and from 0.275 to 0.656% in the adults group. The ICCs (range: 0.860–0.974) in the children group, significantly lower than for the adults (range: 0.989–0.995), in all of the macular sectors.

Conclusions

The reproducibility of SD-OCT RNFL and macular measurements for children was excellent, albeit statistically lower than that for adults.  相似文献   

14.
Primary open angle glaucoma (POAG) is a leading cause of blindness worldwide. The molecular signaling involved in the pathogenesis of POAG remains unknown. Here, we report that mice lacking the α1 subunit of the nitric oxide receptor soluble guanylate cyclase represent a novel and translatable animal model of POAG, characterized by thinning of the retinal nerve fiber layer and loss of optic nerve axons in the context of an open iridocorneal angle. The optic neuropathy associated with soluble guanylate cyclase α1–deficiency was accompanied by modestly increased intraocular pressure and retinal vascular dysfunction. Moreover, data from a candidate gene association study suggests that a variant in the locus containing the genes encoding for the α1 and β1 subunits of soluble guanylate cyclase is associated with POAG in patients presenting with initial paracentral vision loss, a disease subtype thought to be associated with vascular dysregulation. These findings provide new insights into the pathogenesis and genetics of POAG and suggest new therapeutic strategies for POAG.  相似文献   

15.
PurposeTo evaluate the ability of frequency domain optical coherence tomography (fd-OCT) to estimate retinal neural loss in eyes with Alzheimer’s disease (AD). We also verified the existence of a correlation between AD-related cognitive impairment and macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements.Methodsfd-OCT scans were obtained from 45 eyes of 24 patients with AD and 48 control eyes. Peripapillary RNFL, macular full-thickness and segmented inner macular thickness parameters were calculated. The inner macular parameters included macular retinal nerve fiber layer (mRNFL) thickness, ganglion cell layer (GCL) plus inner plexiform layer thickness (GCL+), and RNFL plus GCL+ thickness (GCL++). The Mini-Mental State Examination (MMSE) was used to assess cognition in all subjects. The two groups were compared and the relationship between MMSE scores and fd-OCT measurements was verified.ResultsAverage, superior and inferior quadrant RNFL thickness parameters and all but one of the nine full-thickness macular measurements were significantly reduced in AD patients compared to controls. The segmented layers, GCL+ and GCL++ were significantly reduced in AD eyes. A significant correlation was found between most fd-OCT parameters (especially macular thickness measurements) and MMSE scores.ConclusionsMost fd-OCT peripapillary RNFL and macular full-thickness and segmented inner retinal layers parameters were reduced in AD eyes compared to controls. Moreover, neuronal loss, especially as reflected in macular parameters, correlated well with cognitive impairment in AD. Our results suggest that fd-OCT could be a potentially useful diagnostic tool in the evaluation and follow-up of AD patients.  相似文献   

16.

Purpose

The current study was undertaken to investigate whether glaucoma affects the sleep quality and whether there is any difference between patients with primary glaucoma (primary open angle glaucoma, POAG and primary angle-closure glaucoma, PACG) and healthy subjects, using a validated self-rated questionnaire, the Pittsburgh Sleep Quality Index (PSQI).

Methods

The sleep quality of patients with POAG and PACG was tested against normal controls. Subjects were divided into three sub-groups according to age. Differences in the frequency of sleep disturbances (PSQI score >7) were assessed. The differences of sleep quality within the three groups and within the POAG group depending on the patients’ intraocular pressure (IOP) and impairment of visual field (VF) were also studied.

Results

92 POAG patients, 48 PACG patients and 199 controls were included. Sleep quality declined with age in control and POAG group (tendency chi-square, P<0.05). The prevalence of sleep disturbances was higher in POAG and PACG group than in the control group, the differences were statistically significant. The prevalence of sleep disturbances was higher in patients with PACG, compared to POAG patients in the age interval of 61–80. In POAG group, the ratio of patients with sleep disorders increased with augmented impairment of VF, but the differences were not statistically significant (χ2-test, P>0.05). No significant differences were found in POAG group between patients with a highest IOP in daytime and at nighttime (χ2-test, P>0.05).

Conclusions

The prevalence of sleep disorders was higher in patients with POAG and PACG than in controls. PACG patients seemed to have a more serious problem of sleep disorders than POAG patients between 61 to 80 years old. No correlation was found between the prevalence of sleep disorders and impairment of VF or the time when POAG patients showed a highest IOP.  相似文献   

17.

Objective

To examine microcystic inner nuclear layer (INL) changes in glaucomatous eyes and to determine associated factors.

Design

Retrospective, cross-sectional, observational study.

Methods

Two hundred seventeen eyes of 133 patients with primary open angle glaucoma (POAG), 41 eyes of 32 patients with preperimetric glaucoma and 181 normal eyes of 117 subjects were ultimately included. Microcystic INL lesions were examined with infrared fundus images and with 19 vertical spectral domain optical coherence tomography (SD-OCT) images in the macular area.

Results

Microcystic INL changes were observed in 6.0% of eyes with POAG, but none of the normal eyes or eyes with preperimetric glaucoma showed microcystic INL changes. The proportion of eyes with advanced glaucoma was significantly larger (P = 0.013) in eyes with microcystic lesions than without. The visual field mean deviation (MD) slope was also significantly worse (P = 0.027) in eyes with microcystic lesions. No significant differences were observed in age, sex, refraction, axial length, intraocular pressure, or MD value between eyes with and without microcystic INL lesions. In several cases, microcystic INL lesions occurred along with glaucomatous visual field progression. The retinal nerve fiber layer (RNFL) thickness (P = 0.013) and ganglion cell layer (GCL) + inner plexiform layer thickness (P = 0.023) were significantly lower in areas with microcystic lesions than without. The INL was also significantly thicker (P = 0.002) in areas with microcystic lesions.

Conclusions

Microcystic INL lesions in glaucomatous eyes are closely associated with RNFL and GCL thinning and correlated with worse MD slope. These INL lesions may indicate focal and progressive damage in glaucoma.  相似文献   

18.
The mechanistic study of glaucoma pathogenesis has shifted to seeking to understand the effects of immune responses on retinal ganglion cell damage and protection. Cytokines mediate the biological effects of the immune system, and our previous study revealed an imbalance of T-helper (Th) 1-derived and Th2-derived cytokines in the serum of patients with glaucoma. In this study, we collected irises from normal individuals and patients with primary open-angle closure (POAG) or chronic angle-closure glaucoma (CACG). We used real-time polymerase chain reaction (PCR) to measure the expression of Th1 (interleukin (IL)-2, interferon-gamma (IFN-γ)), Th2 (IL-4, IL-6, IL-10), and Th3 (transforming growth factor-beta (TGF-β)) cytokines. We then performed immunohistochemical staining to characterize the localization of the upregulated cytokines in iris cryosections. We observed an upward trend in the expression of IL-2 and IFN-γ and a downward trend in IL-6 expression in the iris of POAG and CACG patients. Expression of TGF-β also increased. Immunohistochemistry revealed that IL-2 expression in POAG and CACG patients was localized in the anterior surface of the blood vessel wall in the stroma of the iris, in the cytoplasm of some cells, in the anterior epithelium, and in the posterior pigment epithelium. These findings indicate that immune status differed between the iris tissues of POAG and CACG patients and those of normal individuals. A T-helper cytokine imbalance may modulate the immune microenvironment in glaucomatous eyes and thus influence optic neuropathy.  相似文献   

19.

Purpose

To investigate whether lamina cribrosa (LC) defects are associated with optic disc morphology in primary open angle glaucoma (POAG) eyes with high myopia.

Methods

A total of 129 POAG patients and 55 age-matched control subjects with high myopia were evaluated. Three-dimensional scan images obtained by swept source optical coherence tomography were used to detect LC defects. Radial B-scans and infrared images obtained by spectral domain optical coherence tomography were used to measure β-peripapillary atrophy (PPA) lengths with and without Bruch''s membrane (BM) (temporal, nasal, superior, and inferior), tilt angle (vertical and horizontal), and disc diameter (transverse and longitudinal). Peripapillary intrachoroidal cavitations (PICCs), disc area, ovality index, and cyclotorsion of the optic disc were analyzed as well.

Results

LC defects were found in 70 of 129 (54.2%) POAG eyes and 1 of 55 (1.8%) control eyes (P<0.001). Age, sex, spherical equivalent, axial length, intraocular pressure, and central corneal thickness were not significantly different among POAG eyes with LC defects, POAG eyes without LC defects, and control eyes. Temporal PPA lengths without BM in all three groups correlated significantly with vertical and horizontal tilt angles, although no PPA length with BM correlated significantly with any tilt angle. PICCs were detected more frequently in POAG eyes with LC defects than those without LC defects (P = 0.01) and control eyes (P = 0.02). POAG eyes with LC defects showed a smaller ovality index (P = 0.004), longer temporal PPA without BM (P<0.001), and larger vertical/horizontal tilt angles (vertical, P<0.001; horizontal, P = 0.01), and transverse diameter (P = 0.01). In multivariate analysis for the presence of LC defects, presence of POAG (P<0.001) and vertical tilt angle (P<0.001) were identified as significant.

Conclusions

The presence of LC defects was associated with myopic optic disc morphology in POAG eyes with high myopia.  相似文献   

20.

Purpose

To ascertain whether the incidence of ocular dicrotic pulse (ODP) increases with age, it is more pronounced in glaucomatous than in normal eyes and whether it is related to cardiovascular activity.

Methods

261 subjects aged 47 to 78 years were included in the study and classified into four groups: primary open angle glaucoma (POAG), primary angle-closure glaucoma (PACG), glaucoma suspects with glaucomatous optic disc appearance (GODA) and the controls (CG). Additionally, in each group, subjects with ODP were divided into two age subgroups around the median age. A non-contact ultrasonic method was used to measure corneal indentation pulse (CIP) synchronically with the acquisition of electrocardiography (ECG) and blood pulse signals. ODP was assessed from the acquired signals that were numerically processed in a custom written program.

Results

ODP incidence was about 78%, 66%, 66% and 84% for CG, GODA, POAG, and PACG group, respectively. With advancing age, the ODP incidence increased for all subjects (Δ = 12%), the highest being for the PACG and POAG groups (Δ = 30%). GODA group did not show an age-related increase in the incidence of ODP.

Conclusions

The ocular dicrotism, measured with non-contact ultrasonic method, was found to be a common phenomenon in elderly subjects. The increased ODP incidence in PACG and POAG group may correspond to either higher stiffness of glaucoma eyes, biochemical abnormalities in eye tissues, changes in ocular hemodynamics, may reflect the effect of medications or be a combination of all those factors. The results of GODA group suggest different mechanisms governing their ocular pulse that makes them less susceptible to generating ODP and having decreased predisposition to glaucoma.  相似文献   