首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: Combined analysis of DNA content and immunofluorescence on single cells by flow cytometry provides information on the proliferative response of subpopulations to stimuli in mixed cell preparations; however, in low-viability cell preparations, dead cells interfere with accurate flow cytometric data analysis because of nonspecific binding of antibodies and altered DNA-staining profiles. Light scatter differences between nonviable and viable cells are unreliable, particularly after the cell permeabilization step that is necessary for DNA staining. We developed a method for identification of nonviable cells by fluorescence in cell preparations that are stained simultaneously for cell surface or intracellular immunofluorescence and DNA content. MATERIALS AND METHODS: Nonviable cells that have lost membrane integrity are identified by uptake of 7-amino-actinomycin D (7-AAD). Transfer of 7-AAD from stained nonviable cells to unstained viable cells after permeabilization is prevented by blocking DNA binding with nonfluorescent actinomycin D (AD). Pyronin Y(G) (PY) is used for DNA staining because the orange spectral emission of PY can be separated from the green fluorescein isothiocyanate (FITC) emission and the red emission of 7-AAD, respectively. RESULTS: Application of the method to the analysis of the T-cell leukemia cell line Molt-4f and of cultured human peripheral blood mononuclear cells is presented. In both cell preparations, 7-AAD staining permitted reliable dead cell exclusion. Live, 7-AAD-negative Molt-4f cells showed higher expression levels of cell surface CD4 and of intracellular CD3, showed a higher proportion of cells in the G1 phase of the cell cycle, and showed a lower coefficient of variation of the G1 peak compared with data obtained from all the cells in the preparation. Live, CD8+ lymphocytes from OKT3-stimulated cultures of human peripheral blood mononuclear cells showed a specific proliferative response as measured by DNA content analysis. CONCLUSIONS: The results show that cells stained with FITC-labeled antibodies can be analyzed by single-laser flow cytometry for DNA content combined with dead cell discrimination. Furthermore, they emphasize the need for exclusion of dead cells from the analysis of cell preparations with low viability to obtain reliable data on immunofluorescence and cell-cycle distributions.  相似文献   

2.
Identification of nonviable cells in immunofluorescently stained cell populations is essential for obtaining accurate data. Fluorescent non-vital DNA dyes, particularly propidium iodide (PI), have been used routinely in flow cytometry for discrimination of dead cells from viable cells on the basis of fluorescence. We describe here the use of an alternative DNA dye, 7-amino-actinomycin D (7-AAD), which can replace PI for the exclusion of nonviable cells. As an example, we present in this paper the utilization of 7-AAD on various leukemic cell lines for dead cell exclusion whenever the viable cell population could not be discriminated reliably from nonviable cells on the light scatter histogram; 7-AAD is suitable for dead cell discrimination in lengthy experiments because it is efficiently excluded by intact cells and has a high DNA binding constant. In addition, the dye is valuable in combination with phycoerythrin (PE)-fluorescence dual-color flow cytometry on a single argon laser instrument, since its emission in the far red can easily be separated from the emission of PE; 7-AAD was used on fluoresceinisothiocyanate (FITC) and PE surface-labeled human thymocytes for characterization of the dying subpopulation of cells which is undergoing programmed cell death. In this heterogeneous cell preparation, the spectral properties of the dye permitted the classification of viable and nonviable cell subpopulations by multiparameter analysis.  相似文献   

3.
Flow cytometry and fluorescence activated cell sorting techniques were designed to realize configurable classification and separation of target cells. A number of cell phenotypes with different functionalities have recently been revealed. Before simultaneous selective capture of cells, it is desirable to label different samples with the corresponding dyes in a multiplexing manner to allow for a single analysis. However, few methods to obtain multiple fluorescent colors for various cell types have been developed. Even when restricted laser sources are employed, a small number of color codes can be expressed simultaneously. In this study, we demonstrate the ability to manifest DNA nanostructure-based multifluorescent colors formed by a complex of dyes. Highly precise self-assembly of fluorescent dye-conjugated oligonucleotides gives anisotropic DNA nanostructures, Y- and tree-shaped DNA (Y-DNA and T-DNA, respectively), which may be used as platforms for fluorescent codes. As a proof of concept, we have demonstrated seven different fluorescent codes with only two different fluorescent dyes using T-DNA. This method provides maximum efficiency for current flow cytometry. We are confident that this system will provide highly efficient multiplexed fluorescent detection for bioanalysis compared with one-to-one fluorescent correspondence for specific marker detection.  相似文献   

4.
BACKGROUND: Internal standards have been used in flow cytometry methods to enumerate lymphoid subsets and hemopoietic progenitor cells ex vivo. However, the currently available methods cannot be readily applied to the analysis of cultured cells because of the frequent occurrence of cell death during in vitro assays. METHODS: This paper reports a new method for the enumeration of both viable and nonviable cells in culture. Cells were counted with the aid of an internal reference standard of microbeads, and live versus dead cell discrimination was performed using 7-amino-actinomycin D which allows the double staining of surface antigens. RESULTS: The method is more precise, accurate and sensitive than either conventional light microscopy-based or automated cell counting. Additionally, it may be used to accurately measure the number of apoptotic cells in a culture. RESULTS: Through the enumeration of surviving cells it is demonstrated that, when applied to the study of mitogen-activated T lymphocytes, current flow cytometry techniques (which do not use internal standards) for the study of the viability and apoptosis overestimate the fraction of viable cells and underestimate both the fraction of dead and apoptotic cells. CONCLUSIONS: The new method overcomes these limitations and is of use in the in vitro study of cell growth and apoptosis.  相似文献   

5.
BACKGROUND: Cytomics aims at understanding the function of cellular systems by analysis of single cells. Recently, there has been a growing interest in single cell measurements being performed in microfluidic systems. These systems promise to integrate staining, measurement, and analysis in a single system. One important aspect is the limitation of allowable cell sizes due to microfluidic channel dimensions. Here we want to demonstrate the broad applicability of microfluidic chip technology for the analysis of many different cell types. METHODS: We have developed a microfluidic chip and measurement system that allows flow cytometric analysis of fluorescently stained cells from different organisms. In this setup, the cells are moved by pressure-driven flow inside a network of microfluidic channels and are analyzed individually by fluorescence detection. RESULTS: We have successfully applied the system to develop a methodology to detect viable and dead cells in yeast cell populations. Also, we have measured short interfering RNA (siRNA) mediated silencing of protein expression in mammalian cells. In addition, we have characterized the infection state of Magnaportae grisea fungal spores. CONCLUSIONS: Results obtained with the microfluidic system demonstrate a broad applicability of microfluidic flow cytometry to measurement of various cell types.  相似文献   

6.
BACKGROUND: Methods widely used to detect apoptosis do not allow us to easily distinguish between nuclei from viable or necrotic cells. Even if apoptosis and necrosis seem to occur as alternatives at the single cell level, they could be present simultaneously in a cell population much more frequently than expected. For this reason, attention was focused on attempting to recognize, by multiparameter flow cytometry, the characteristics of viable cells and of apoptotic or necrotic dead cells. METHODS: Apoptosis and necrosis were induced in vitro in murine thymocytes and lymphocytes from adult peripheral blood by using dexamethasone or prostaglandin E2 treatment and heat shock at 60 degrees C or hydrogen peroxide, respectively. Traditional methods, such as DNA gel electrophoresis and propidium iodide staining followed by single-fluorescence analysis or annexin-V-fluorescein isothiocyanate plus propidium iodide staining by using flow cytometry, were compared with a new method. This method consisted of combined light-scatter and red fluorescence analysis by flow cytometry after isolation of nuclei by hypotonic solution as well as high-dose detergent treatment and DNA staining with propidium iodide. RESULTS: Results showed that, although traditional methods such as DNA-gel electrophoresis and single-parameter fluorescence flow cytometry analysis were unable, as expected, to discriminate among viability, apoptosis, and necrosis, our new method has enabled us to easily identify nuclei from viable, apoptotic, and necrotic cells. Results obtained by using our method were comparable to those obtained by using two-color analysis of cells after propidium iodide/annexin V staining. CONCLUSIONS: A highly reproducible, inexpensive, rapid, and easily accessible method of analysis has been developed for simultaneously detecting apoptosis and necro sis.  相似文献   

7.
Schistosoma mansoni eggs are classified, according to morphological characteristics, as follows: viable mature and immature eggs; dead mature and immature eggs, shells and granulomas. The scope of this study was to compare the staining characteristics of different morphological types of eggs in the presence of fluorescent labels and vital dyes, aiming at differentiating live and dead eggs. The eggs were obtained from the intestines of infected mice, and put into saline 0.85%. The fluorescent labels were Hoechst 33258 and Acridine Orange + Ethidium Bromide and vital dyes (Trypan Blue 0.4% and Neutral Red 1%). When labelled with the probe Hoechst 33258, some immature eggs, morphologically considered viable, presented fluorescence (a staining characteristic detected only in dead eggs); mature eggs did not present fluorescence, and the other types of dead eggs, morphologically defined, showed fluorescence. As far as Acridine Orange + Ethidium Bromide are concerned, either the eggs considered to be live, or the dead ones, presented staining with green color, and only the hatched and motionless miracidium was stained with an orange color. Trypan Blue was not able to stain the eggs, considered to be dead but only dead miracidia which had emerged out of the shell. Neutral Red stained both live and dead eggs. Only the fluorescent Hoechst 33258 can be considered a useful tool for differentiation between dead and live eggs.  相似文献   

8.
K Toba  E F Winton  R A Bray 《Cytometry》1992,13(1):60-67
We have developed an improved technique for triple staining that permits the simultaneous flow cytofluorometric analysis of cell surface antigens, bromodeoxyuridine incorporation into DNA, and DNA quantification using 7-amino-actinomycin D. PHA-activated human peripheral blood lymphocytes were incubated with bromodeoxyuridine and stained for cell surface phenotype with phycoerythrin-labeled monoclonal antibodies. Stained cells were fixed serially with 1% paraformaldehyde and 45% ethanol. Fixed cells were sequentially stained with an anti-BrdUrd monoclonal antibody followed by a FITC-conjugated goat anti-mouse antibody and incubated with 7-amino-actinomycin D. Hypotonic buffer was employed for all procedures after fixation. Stained-fixed cells were analyzed by flow cytofluorometry for simultaneous green (525 nm), orange (570 nm), and red (greater than 650 nm) fluorescence. Utilizing this staining technique, we were able to analyze simultaneously cell phenotype, DNA synthesis, and total cellular DNA content with single laser excitation.  相似文献   

9.
BACKGROUND: Several staining protocols have been developed for flow cytometric analysis of bacterial viability. One promising method is dual staining with the LIVE/DEAD BacLight bacterial viability kit. In this procedure, cells are treated with two different DNA-binding dyes (SYTO9 and PI), and viability is estimated according to the proportion of bound stain. SYTO9 diffuses through the intact cell membrane and binds cellular DNA, while PI binds DNA of damaged cells only. This dual-staining method allows effective separation between viable and dead cells, which is far more difficult to achieve with single staining. Although SYTO9-PI dual staining is practical for various bacterial viability analyses, the method has a number of disadvantages. Specifically, the passage of SYTO9 through the cell membrane is a slow process, which is significantly accelerated when the integrity of the cell membrane is disrupted. As a result, SYTO9 binding to DNA is considerably enhanced. PI competes for binding sites with SYTO9 and may displace the bound dye. These properties diminish the reliability of the LIVE/DEAD viability kit. In this study, we investigate an alternative method for measuring bacterial viability using a combination of green fluorescent protein (GFP) and PI, with a view to improving data reliability. METHODS: Recombinant Escherichia coli cells with a plasmid containing the gene for jellyfish GFP were stained with PI, and green and red fluorescence were measured by FCM. For comparison, cells containing the plasmid from which gfp was removed were stained with SYTO9 and PI, and analyzed by FCM. Viability was estimated according to the proportion of green and red fluorescence. In addition, bioluminescence and plate counting (other methods to assess viability) were used as reference procedures. RESULTS: SYTO9-PI dual staining of bacterial cells revealed three different cell populations: living, compromised, and dead cells. These cell populations were more distinct when the GFP-PI combination was used instead of dual staining. No differences in sensitivity were observed between the two methods. However, substitution of SYTO9 with GFP accelerated the procedure. Bioluminescence and plate counting results were in agreement with flow cytometric viability data. CONCLUSIONS: In bacterial viability analyses, the GFP-PI combination provided better distinction between current viability stages of E. coli cells than SYTO9-PI dual staining. Additionally, the overall procedure was more rapid. No marked differences in sensitivity were observed.  相似文献   

10.
A dual laser flow system has been proved and used with a novel staining method for simultaneous quantitative DNA and protein analysis. A diamidinophenylindole compound (DAPI) for DNA has been employed in combination with sulforhodamine (SR 101) for protein. With this dye mixture various cell types of the cervical smear could be identified. Despite some overlapping, clusters of leukocytes, endocervicals, (para)basals, intermediates, superficials and dys/neoplastic cells together with artificial events could be discriminated. Up to now the problem of negative cells which create positive signals (false alarms) in the dys/neoplastic region could not be sufficiently solved.  相似文献   

11.
We developed a rapid technique for preservation of Hoechst 33342/propidium iodide-stained cells, using ethanol as a fixative. Combined staining with these dyes makes possible analysis of cell-cycle phase-specific cell death. The technique relies on exclusion of propidium iodide from the viable cells, whereas Hoechst stains all of the cells. The bivariate histograms resulting from the flow cytometric analysis contain the equivalent of two single-parameter DNA histograms, one of the living and the other of the dead cell population. Preservation of staining involved addition of 25% ethanol in PBS after propidium iodide staining and before Hoechst staining. The separation between the living and the dead cell populations was maintained for over 3 days at 4 degrees C. This technique will be valuable for quantitative evaluation of the cell-cycle phase-specific effects of cytostatic or cytotoxic agents, particularly in situations where a lag period between staining and analysis is unavoidable.  相似文献   

12.
Understanding how quiescent and apoptotic populations form in tumors is necessary because these cell types can considerably diminish therapeutic efficacy. Most cancer therapeutics are ineffective against quiescent cells because they target rapidly proliferating cells. Distinguishing apoptosis is important because apoptotic cells are committed to death and do not require treatment. Regrowth of quiescent cell can lead to tumor re-occurrence and metastasis, which are the leading causes of cancer mortality. We hypothesized that cylindroid cultures and acridine orange staining could be used to determine how nutrient diffusion creates apoptotic and quiescent regions in tumors. To test this hypothesis we developed a microscopy technique to measure cellular DNA and RNA content in single cells using thin cylindroids and acridine orange staining. Cell classification was compared to flow cytometry of cells grown in defined monolayer cultures. The presence of apoptosis was confirmed by morphological nuclear analysis. The effect of diffusion was determined by varying incubation time, cylindroid size, and exposing cylindroids to nutrient-deficient media. Four overlapping regions were identified as a function of cylindroid radius: an outer viable/quiescent region; a second quiescent/apoptotic region; a third late-stage apoptotic region; and an inner dead region. In monolayer cultures the absence of glutamine and growth factors induced apoptosis and hypoxia induced quiescence. Treating with nutrient-deficient media suggested that cells became quiescent near the periphery because of glucose and oxygen limitations, and became apoptotic and died further from the edge because of glutamine and growth factor limitations. These results show that cellular microenvironments can be identified in cylindroids using simple acridine orange staining and that single cell fluorescence can be measured in three-dimensional culture. The developed techniques will be useful for developing cancer therapies and determining how cell death and apoptosis are induced in three-dimensional tumor tissue.  相似文献   

13.
Yeast viability can be accurately quantified using BacLight, a kit which so far has been used only for bacterial analysis. Upon staining, viable cells can be differentiated from non-viable ones by either confocal laser scanning microscopy (CLSM), epifluorescence microscopy, or flow cytometry. Using Saccharomyces cerevisiae as a model, viabilities quantified by CLSM deviated an average of 1.7% from the actual data, and those determined by flow-cytometry by 1.4%.  相似文献   

14.
Microarray and RT-PCR based methods are important tools for analysis of gene expression; however, in tissues containing many different cells types, such as the testis, characterization of gene expression in specific cell types can be severely hampered by noise from other cells. The laser microdissection technology allows for enrichment of specific cell types. However, when the cells are not morphologically distinguishable, it is necessary to use a specific staining method for the target cells. In this study we have tested different fixatives, storage conditions for frozen sections and staining protocols, and present two staining protocols for frozen sections, one for fast and specific staining of fetal germ cells, testicular carcinoma in situ cells, and other cells with embryonic stem cell-like properties that express the alkaline phosphatase, and one for specific staining of lipid droplet-containing cells, which is useful for isolation of the androgen-producing Leydig cells. Both protocols retain a morphology that is compatible with laser microdissection and yield RNA of a quality suitable for PCR and microarray analysis.  相似文献   

15.
Real-time PCR is fast, sensitive, specific, and can deliver quantitative data; however, two disadvantages are that this technology is sensitive to inhibition by food and that it does not distinguish between DNA originating from viable, viable nonculturable (VNC), and dead cells. For this reason, real-time PCR has been combined with a novel discontinuous buoyant density gradient method, called flotation, in order to allow detection of only viable and VNC cells of thermotolerant campylobacters in chicken rinse samples. Studying the buoyant densities of different Campylobacter spp. showed that densities changed at different time points during growth; however, all varied between 1.065 and 1.109 g/ml. These data were then used to develop a flotation assay. Results showed that after flotation and real-time PCR, cell concentrations as low as 8.6 x 10(2) CFU/ml could be detected without culture enrichment and amounts as low as 2.6 x 10(3) CFU/ml could be quantified. Furthermore, subjecting viable cells and dead cells to flotation showed that viable cells were recovered after flotation treatment but that dead cells and/or their DNA was not detected. Also, when samples containing VNC cells mixed with dead cells were treated with flotation after storage at 4 or 20 degrees C for 21 days, a similar percentage resembling the VNC cell fraction was detected using real-time PCR and 5-cyano-2,3-ditolyl tetrazolium chloride-4',6'-diamidino-2-phenylindole staining (20% +/- 9% and 23% +/- 4%, respectively, at 4 degrees C; 11% +/- 4% and 10% +/- 2%, respectively, at 20 degrees C). This indicated that viable and VNC Campylobacter cells could be positively selected and quantified using the flotation method.  相似文献   

16.
It has been widely demonstrated that perfusion bioreactors improve in vitro three‐dimensional (3D) cultures in terms of high cell density and uniformity of cell distribution; however, the studies reported in literature were primarily based on qualitative analysis (histology, immunofluorescent staining) or on quantitative data averaged on the whole population (DNA assay, PCR). Studies on the behavior, in terms of cell cycle, of a cell population growing in 3D scaffolds in static or dynamic conditions are still absent. In this work, a perfusion bioreactor suitable to culture C2C12 muscle precursor cells within 3D porous collagen scaffolds was designed and developed and a method based on flowcytometric analyses for analyzing the cell cycle in the cell population was established. Cells were extracted by enzymatic digestion of the collagen scaffolds after 4, 7, and 10 days of culture, and flow cytometric live/dead and cell cycle analyses were performed with Propidium Iodide. A live/dead assay was used for validating the method for cell extraction and staining. Moreover, to investigate spatial heterogeneity of the cell population under perfusion conditions, two stacked scaffolds in the 3D domain, of which only the upstream layer was seeded, were analyzed separately. All results were compared with those obtained from static 3D cultures. The live/dead assay revealed the presence of less than 20% of dead cells, which did not affect the cell cycle analysis. Cell cycle analyses highlighted the increment of cell fractions in proliferating phases (S/G2/M) owing to medium perfusion in long‐term cultures. After 7–10 days, the percentage of proliferating cells was 8–12% for dynamic cultures and 3–5% for the static controls. A higher fraction of proliferating cells was detected in the downstream scaffold. From a general perspective, this method provided data with a small standard deviation and detected the differences between static and dynamic cultures and between upper and lower scaffolds. Our methodology can be extended to other cell types to investigate the influence of 3D culture conditions on the expression of other relevant cell markers. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

17.
Flow cytometric multiparameter analysis of two proliferation-associated nuclear antigens (proliferating cell nuclear antigen (PCNA)/cyclin and Ki-67) was performed on seven human hematopoietic cell lines. PCNA/cyclin, an S phase-related antigen, was detected using an autoantibody and a fluorescein isothiocyanate-labeled anti-human antibody. The Ki-67 antigen, which in cycling cells is expressed with increasing levels during the S phase with a maximum in the M phase, was detected using a monoclonal antibody and a phycoerythrin-conjugated anti-mouse antibody. In some experiments the PCNA/Ki-67 staining was combined with a DNA stain, 7-amino actinomycin D, and simultaneous detection of the three stains was performed by a single laser flow cytometer. Using this technique four distinct cell populations, representing G1, S, G2, and M, respectively, could be demonstrated in cycling cells on the basis of their PCNA/cyclin and Ki-67 levels. The cell cycle phase specificity could be verified using metaphase (vinblastine, colcemide) and G2 phase (mitoxantrone) blocking agents, as well as by stainings with a mitosis-specific antibody (MPM-2). Also, G0 cells could be discriminated from G1 cells in analysis of a mixture of resting peripheral mononuclear blood cells and a proliferating cell line. This technique can be valuable in detailed cell cycle analysis, since all cell cycle phases can be visualized and calculated using a simple double staining procedure.  相似文献   

18.
Monoclonal antibodies specific for phycoerythrin (PE) were covalently labeled with the fluorescent dye cyanine 5 (Cy5). Excitation at 488 nm of immune complexes obtained by mixing Cy5-anti-PE with PE resulted in a 4-fold reduction of PE fluorescence measured at 565 nm and an increase of fluorescence measured at 655 nm. The observed energy transfer between PE and Cy5-anti-PE was used to develop three color immunofluorescence staining procedures for flow cytometers equipped with an Argon laser tuned at 488 nm. Mouse IgG1 monoclonal antibodies specific for cell surface antigens were cross-linked with either unlabeled or Cy5 labeled mouse IgG1 anti-PE using F(ab')2 fragments of monoclonal rat anti-mouse IgG1. PE was added to these immune complexes in sufficient amounts to saturate all PE binding sites. Cells were incubated with PE-labeled and PE/Cy5-labeled tetrameric antibody complexes together with FITC labeled antibodies and analyzed by flow cytometry. The emission from FITC, PE and PE/Cy5 could be readily separated and bright three color immunofluorescence staining of mononuclear cells from human peripheral blood and bone marrow was observed. The results of these experiments demonstrate that useful probes for single laser three color staining of cell surface antigens can be readily obtained by mixing of selected reagents. Compared to standard procedures for the covalent labeling of PE (tandem) molecules to antibodies, the non-covalent procedures described in this report provide significant advantages in terms of the amount of reagents, time and equipment required to obtain suitable reagents for three color immunofluorescence staining.  相似文献   

19.
A simple trypan blue-neutral red-Giemsa staining procedure for simultaneous evaluation of acrosome, sperm head, and tail membrane integrity and morphology has been used to evaluate equine spermatozoa. Some special characteristics and problems have arisen in evaluating stallion semen. One problem was the differentiation of intact vs. damaged sperm tails primarily in frozen and thawed samples. After freezing and thawing, a high percentage of spermatozoa with an unstained head and stained tail were observed. These cells are considered immotile. Therefore, unambiguous differentiation of intact vs. damaged sperm tail membrane is very important for evaluating semen quality. The aim of our study was to develop a method especially for stallion sperm to distinguish more accurately the different cell types. We compared Chicago sky blue 6B (CSB) to trypan blue (TB) for viability staining. CSB/Giemsa staining showed good repeatability and agreement with TB/Giemsa measurements. For densitometry analysis, individual digital images were taken from smears stained by CSB/Giemsa and by TB/Giemsa. A red-green-blue (RGB) histogram for each area of spermatozoa was drawn. Differences of means of RGB values of live vs. dead tails and separate live vs. dead heads from each photo were used to compare the two staining procedures. CSB produced similar live/dead sperm head differentiation and better tail differentiation. TB can be replaced by CSB and this results in more reliable evaluation. After staining with 0.16% CSB and 4 min fixation, 2-4 h Giemsa staining at 25-40° C is recommended for stallion semen.  相似文献   

20.
In rural areas around the world, people often rely on water filtration plants using activated carbon particles for safe water supply. Depending on the carbon surface, adhering microorganisms die or grow to form a biofilm. Assays to assess the efficacy of activated carbons in bacterial removal do not allow direct observation of bacterial adhesion and the determination of viability. Here we propose to use a parallel plate flow chamber with carbon particles attached to the bottom plate to study bacterial adhesion to individual carbon particles and determine the viability of adhering bacteria. Observation and enumeration is done after live/dead staining in a confocal laser scanning microscope. Escherichiae coli adhered in higher numbers than Raoultella terrigena, except to a coconut-based carbon, which showed low bacterial adhesion compared to other wood-based carbon types. After adhesion, 83-96% of the bacteria adhering to an acidic carbon were dead, while on a basic carbon 54-56% were dead. A positively charged, basic carbon yielded 76-78% bacteria dead, while on a negatively charged coconut-based carbon only 32-37% were killed upon adhesion. The possibility to determine both adhesion as well as the viability of adhering bacteria upon adhesion to carbon particles is most relevant, because if bacteria adhere but remain viable, this still puts the water treatment system at risk, as live bacteria can grow and form a biofilm that can then be shedded to cause contamination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号