首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
转盘共聚焦显微镜是快速激光共聚焦显微镜的一种,与传统的激光共聚焦显微镜相比具有一些相同点,也有其特有的优势。本文主要介绍转盘共聚焦显微镜的基本原理及如何利用转盘共聚焦显微镜进行快速实验及应用实例,并与传统激光共聚焦显微镜进行比较。转盘共聚焦显微镜具有速度快、灵敏度高、对样品光损伤和光淬灭程度低、操作灵活简单,是随着实验技术发展使用越来越广泛的实验仪器。  相似文献   

2.
We develop an extension of fluorescence correlation spectroscopy (FCS) using a spinning disk confocal microscope. This approach can spatially map diffusion coefficients or flow velocities at up to approximately 10(5) independent locations simultaneously. Commercially available cameras with frame rates of 1000 Hz allow FCS measurements of systems with diffusion coefficients D~10(-7) cm(2)/s or smaller. This speed is adequate to measure small microspheres (200-nm diameter) diffusing in water, or hindered diffusion of macromolecules in complex media (e.g., tumors, cell nuclei, or the extracellular matrix). There have been a number of recent extensions to FCS based on laser scanning microscopy. Spinning disk confocal microscopy, however, has the potential for significantly higher speed at high spatial resolution. We show how to account for a pixel size effect encountered with spinning disk confocal FCS that is not present in standard or scanning FCS, and we introduce a new method to correct for photobleaching. Finally, we apply spinning disk confocal FCS to microspheres diffusing in Type I collagen, which show complex spatially varying diffusion caused by hydrodynamic and steric interactions with the collagen matrix.  相似文献   

3.
Most current superresolution (SR) microscope techniques surpass the diffraction limit at the expense of temporal resolution, compromising their applications to live-cell imaging. Here we describe a new SR fluorescence microscope based on confocal microscope optics, which we name the spinning disk superresolution microscope (SDSRM). Theoretically, the SDSRM is equivalent to a structured illumination microscope (SIM) and achieves a spatial resolution of 120 nm, double that of the diffraction limit of wide-field fluorescence microscopy. However, the SDSRM is 10 times faster than a conventional SIM because SR signals are recovered by optical demodulation through the stripe pattern of the disk. Therefore a single SR image requires only a single averaged image through the rotating disk. On the basis of this theory, we modified a commercial spinning disk confocal microscope. The improved resolution around 120 nm was confirmed with biological samples. The rapid dynamics of micro­tubules, mitochondria, lysosomes, and endosomes were observed with temporal resolutions of 30–100 frames/s. Because our method requires only small optical modifications, it will enable an easy upgrade from an existing spinning disk confocal to a SR microscope for live-cell imaging.  相似文献   

4.
FP Martial  NA Hartell 《PloS one》2012,7(8):e43942
Confocal microscopy is routinely used for high-resolution fluorescence imaging of biological specimens. Most standard confocal systems scan a laser across a specimen and collect emitted light passing through a single pinhole to produce an optical section of the sample. Sequential scanning on a point-by-point basis limits the speed of image acquisition and even the fastest commercial instruments struggle to resolve the temporal dynamics of rapid cellular events such as calcium signals. Various approaches have been introduced that increase the speed of confocal imaging. Nipkov disk microscopes, for example, use arrays of pinholes or slits on a spinning disk to achieve parallel scanning which significantly increases the speed of acquisition. Here we report the development of a microscope module that utilises a digital micromirror device as a spatial light modulator to provide programmable confocal optical sectioning with a single camera, at high spatial and axial resolution at speeds limited by the frame rate of the camera. The digital micromirror acts as a solid state Nipkov disk but with the added ability to change the pinholes size and separation and to control the light intensity on a mirror-by-mirror basis. The use of an arrangement of concave and convex mirrors in the emission pathway instead of lenses overcomes the astigmatism inherent with DMD devices, increases light collection efficiency and ensures image collection is achromatic so that images are perfectly aligned at different wavelengths. Combined with non-laser light sources, this allows low cost, high-speed, multi-wavelength image acquisition without the need for complex wavelength-dependent image alignment. The micromirror can also be used for programmable illumination allowing spatially defined photoactivation of fluorescent proteins. We demonstrate the use of this system for high-speed calcium imaging using both a single wavelength calcium indicator and a genetically encoded, ratiometric, calcium sensor.  相似文献   

5.
Summary— Confocal scanning optical microscopy has significant advantages over conventional fluorescence microscopy: it rejects the out-of-locus light and provides a greater resolution than the wide-field microscope. In laser scanning optical microscopy, the specimen is scanned by a diffraction-limited spot of laser light and the fluorescence emission (or the reflected light) is focused onto a photodetector. The imaged point is then digitized, stored into the memory of a computer and displayed at the appropriate spatial position on a graphic device as a part of a two-dimensional image. Thus, confocal scanning optical microscopy allows accurate non-invasive optical sectioning and further three-dimensional reconstruction of biological specimens. Here we review the recent technological aspects of the principles and uses of the confocal microscope, and we introduce the different methods of three-dimensional imaging.  相似文献   

6.
Significant advances in fluorescence microscopy tend be a balance between two competing qualities wherein improvements in resolution and low light detection are typically accompanied by losses in acquisition rate and signal-to-noise, respectively. These trade-offs are becoming less of a barrier to biomedical research as recent advances in optoelectronic microscopy and developments in fluorophore chemistry have enabled scientists to see beyond the diffraction barrier, image deeper into live specimens, and acquire images at unprecedented speed. Selective plane illumination microscopy has provided significant gains in the spatial and temporal acquisition of fluorescence specimens several mm in thickness. With commercial systems now available, this method promises to expand on recent advances in 2-photon deep-tissue imaging with improved speed and reduced photobleaching compared to laser scanning confocal microscopy. Superresolution microscopes are also available in several modalities and can be coupled with selective plane illumination techniques. The combination of methods to increase resolution, acquisition speed, and depth of collection are now being married to common microscope systems, enabling scientists to make significant advances in live cell and in situ imaging in real time. We show that light sheet microscopy provides significant advantages for imaging live zebrafish embryos compared to laser scanning confocal microscopy.  相似文献   

7.
We present a truly quantitative fluorescence recovery after photobleaching (FRAP) model for use with the confocal laser scanning microscope based on the photobleaching of a long line segment. The line FRAP method is developed to complement the disk FRAP method reported before. Although being more subject to the influence of noise, the line FRAP model has the advantage of a smaller bleach region, thus allowing for faster and more localized measurements of the diffusion coefficient and mobile fraction. The line FRAP model is also very well suited to examine directly the influence of the bleaching power on the effective bleaching resolution. We present the outline of the mathematical derivation, leading to a final analytical expression to calculate the fluorescence recovery. We examine the influence of the confocal aperture and the bleaching power on the measured diffusion coefficient to find the optimal experimental conditions for the line FRAP method. This will be done for R-phycoerythrin and FITC-dextrans of various molecular weights. The ability of the line FRAP method to measure correctly absolute diffusion coefficients in three-dimensional samples will be evaluated as well. Finally we show the application of the method to the simultaneous measurement of free green fluorescent protein diffusion in the cytoplasm and nucleus of living A549 cells.  相似文献   

8.
In brain slices, resolving fast Ca2+ fluorescence signals from submicron structures is typically achieved using 2‐photon or confocal scanning microscopy, an approach that limits the number of scanned points. The novel multiplexing confocal system presented here overcomes this limitation. This system is based on a fast spinning disk, a multimode diode laser and a novel high‐resolution CMOS camera. The spinning disk, running at 20 000 rpm, has custom‐designed spiral pattern that maximises light collection, while rejecting out‐of‐focus fluorescence to resolve signals from small neuronal compartments. Using a 60× objective, the camera permits acquisitions of tens of thousands of pixels at resolutions of ~250 nm per pixel in the kHz range with 14 bits of digital depth. The system can resolve physiological Ca2+ transients from submicron structures at 20 to 40 μm below the slice surface, using the low‐affinity Ca2+ indicator Oregon Green BAPTA‐5N. In particular, signals at 0.25 to 1.25 kHz were resolved in single trials, or through averages of a few recordings, from dendritic spines and small parent dendrites in cerebellar Purkinje neurons. Thanks to an unprecedented combination of temporal and spatial resolution with relatively simple implementation, it is expected that this system will be widely adopted for multisite monitoring of Ca2+ signals.   相似文献   

9.
Light sheet microscopy is an easy to implement and extremely powerful alternative to established fluorescence imaging techniques such as laser scanning confocal, multi-photon and spinning disk microscopy. By illuminating the sample only with a thin slice of light, photo-bleaching is reduced to a minimum, making light sheet microscopy ideal for non-destructive imaging of fragile samples over extended periods of time. Millimeter-sized samples can be imaged rapidly with high resolution and high depth penetration. A large variety of instruments have been developed and optimized for a number of different samples: Bessel beams form thin light sheets for single cells, and selective plane illumination microscopy (SPIM) offers multi-view acquisition to image entire embryos with isotropic resolution. This review explains how light sheet microscopy involves a conceptually new microscope design and how it changes modern imaging in biology.  相似文献   

10.
High-performance confocal system for microscopic or endoscopic applications   总被引:1,自引:0,他引:1  
We designed a high-performance confocal system that can be easily adapted to an existing light microscope or coupled with an endoscope for remote imaging. The system employs spatially and temporally patterned illumination produced by one of several mechanisms, including a micromirror array video projection device driven by a computer video source or a microlens array scanned by a piezo actuator in the microscope illumination path. A series of subsampled "component" video images are acquired from a solid-state video camera. Confocal images are digitally reconstructed using "virtual pinhole" synthetic aperture techniques applied to the collection of component images. Unlike conventional confocal techniques that raster scan a single detector and illumination point, our system samples multiple locations in parallel, with particular advantages for monitoring fast dynamic processes. We compared methods of patterned illumination and confocal image reconstruction by characterizing the point spread function, contrast, and intensity of imaged objects. Sample 3D reconstructions include a diatom and a Golgi-stained nerve cell collected in transmission.  相似文献   

11.
Multi-point scanning confocal microscopy using a Nipkow disk enables the acquisition of fluorescent images with high spatial and temporal resolutions. Like other single-point scanning confocal systems that use Galvano meter mirrors, a commercially available Nipkow spinning disk confocal unit, Yokogawa CSU10, requires lasers as the excitation light source. The choice of fluorescent dyes is strongly restricted, however, because only a limited number of laser lines can be introduced into a single confocal system. To overcome this problem, we developed an illumination system in which light from a mercury arc lamp is scrambled to make homogeneous light by passing it through a multi-mode optical fiber. This illumination system provides incoherent light with continuous wavelengths, enabling the observation of a wide range of fluorophores. Using this optical system, we demonstrate both the high-speed imaging (up to 100 Hz) of intracellular Ca(2+) propagation, and the multi-color imaging of Ca(2+) and PKC-gamma dynamics in living cells.  相似文献   

12.
Primary rat neonatal cardiomyocytes are useful in basic in vitro cardiovascular research because they can be easily isolated in large numbers in a single procedure. Due to advances in microscope technology it is relatively easy to capture live cell images for the purpose of investigating cellular events in real time with minimal concern regarding phototoxicity to the cells. This protocol describes how to take live cell timelapse images of primary rat neonatal cardiomyocytes using a confocal spinning disk microscope following lentiviral and adenoviral transduction to modulate properties of the cell. The application of two different types of viruses makes it easier to achieve an appropriate transduction rate and expression levels for two different genes. Well focused live cell images can be obtained using the microscope’s autofocus system, which maintains stable focus for long time periods. Applying this method, the functions of exogenously engineered proteins expressed in cultured primary cells can be analyzed. Additionally, this system can be used to examine the functions of genes through the use of siRNAs as well as of chemical modulators.  相似文献   

13.
Scanning confocal microscopes offer improved rejection of out-of-focus noise and greater resolution than conventional imaging. In such a microscope, the imaging and condenser lenses are identical and confocal. These two lenses are replaced by a single lens when epi-illumination is used, making confocal imaging particularly applicable to incident light microscopy. We describe the results we have obtained with a confocal system in which scanning is performed by moving the light beam, rather than the stage. This system is considerably faster than the scanned stage microscope and is easy to use. We have found that confocal imaging gives greatly enhanced images of biological structures viewed with epifluorescence. The improvements are such that it is possible to optically section thick specimens with little degradation in the image quality of interior sections.  相似文献   

14.
Caenorhabditis elegans has often been used as a model system in studies of early developmental processes. The transparency of the embryos, the genetic resources, and the relative ease of transformation are qualities that make C. elegans an excellent model for early embryogenesis. Laser-based confocal microscopy and fluorescently labeled tags allow researchers to follow specific cellular structures and proteins in the developing embryo. For example, one can follow specific organelles, such as lysosomes or mitochondria, using fluorescently labeled dyes. These dyes can be delivered to the early embryo by means of microinjection into the adult gonad. Also, the localization of specific proteins can be followed using fluorescent protein tags. Examples are presented here demonstrating the use of a fluorescent lysosomal dye as well as fluorescently tagged histone and ubiquitin proteins. The labeled histone is used to visualize the DNA and thus identify the stage of the cell cycle. GFP-tagged ubiquitin reveals the dynamics of ubiquitinated vesicles in the early embryo. Observations of labeled lysosomes and GFP:: ubiquitin can be used to determine if there is colocalization between ubiquitinated vesicles and lysosomes. A technique for the microinjection of the lysosomal dye is presented. Techniques for generating transgenenic strains are presented elsewhere (1, 2). For imaging, embryos are cut out of adult hermaphrodite nematodes and mounted onto 2% agarose pads followed by time-lapse microscopy on a standard laser scanning confocal microscope or a spinning disk confocal microscope. This methodology provides for the high resolution visualization of early embryogenesis.  相似文献   

15.
The use of fluorescent detection methods in association with digital microscopy technologies is an innovative approach for tissue localisation of messenger RNA. The success of such methods relies on the tissue preservation, local availability of the probe and on the existence of high resolution tridimensional analysis systems. Cryostatic sections, mild denaturation, short oligonucleotide probes (20mer) and confocal laser scanning microscopy allow the fulfillment of all these conditions avoiding photobleaching and tissue autofluorescence. In this paper, we describe in detail a method for in situ hybridisation set up with digoxigenin-coupled oligonucleotide complementary to beta-actin mRNA as a probe and an anti-hapten fluorescent antibody as second step for detecting specific hybridisation. Fluorescence was analysed by means of a confocal laser scanning microscope (CLSM) that provides images with low out-of-focus blurring also with relatively low numerical aperture (NA) objectives. We propose also an easy method to perform semi-quantitative thresholding analysis which allows to discriminate between background and specific signal.  相似文献   

16.
Bacillus cereus B-02对Botrytis cinerea 拮抗机理的研究   总被引:1,自引:0,他引:1  
刘婧  马汇泉  刘东武  董瑾  杨晓 《菌物学报》2008,27(6):930-939
采用电子显微镜(扫描、透射)和激光扫描共聚焦显微镜,从细胞形态学和生理学水平上研究蜡样芽孢杆菌Bacillus cereus B-02过滤液对灰葡萄孢菌Botrytis cinerea的拈抗机理.结果表明,处理菌丝表面形态受到严重破坏,发牛强烈变形;荫丝细胞核、线粒体和细胞壁等哑细胞结构发生了明显改变,细胞内出现大量无膜透明内含物,并产生较人液泡.此外,处理菌丝DNA、线粒体膜电位和活性氧荧光强度均低于对照组,且差异极显著;说明B-02菌株对病原真菌菌丝细胞DNA的合成、线粒体膜电位和活性氧水平有重要影响.  相似文献   

17.
采用电子显微镜(扫描、透射)和激光扫描共聚焦显微镜,从细胞形态学和生理学水平上研究蜡样芽孢杆菌Bacillus cereus B-02过滤液对灰葡萄孢菌Botrytis cinerea的拮抗机理。结果表明,处理菌丝表面形态受到严重破坏,发生强烈变形;菌丝细胞核、线粒体和细胞壁等亚细胞结构发生了明显改变,细胞内出现大量无膜透明内含物,并产生较大液泡。此外,处理菌丝DNA、线粒体膜电位和活性氧荧光强度均低于对照组,且差异极显著;说明B-02菌株对病原真菌菌丝细胞DNA的合成、线粒体膜电位和活性氧水平有重要影响。  相似文献   

18.
We have customized a Nipkow spinning disk confocal microscope (SDCM) to acquire three-dimensional (3D) versus time data for live, intraerythrocytic malarial parasites. Since live parasites wiggle within red blood cells, conventional laser scanning confocal microscopy produces blurred 3D images after reconstruction of z stack data. In contrast, since SDCM data sets at high x, y, and z resolution can be acquired in hundreds of milliseconds, key aspects of live parasite cellular biochemistry can be much better resolved on physiologically meaningful times scales. In this paper, we present the first 3D DIC transmittance "z stack" images of live malarial parasites and use those to quantify hemozoin (Hz) produced within the living parasite digestive vacuole, under physiologic conditions. Using live synchronized cultures and voxel analysis of sharpened DIC z stacks, we present the first quantitative in vivo analysis of the rate of Hz growth for chloroquine sensitive (CQS) versus resistant (CQR) malarial parasites. We present data for laboratory strains, as well as pfcrt transfectants expressing a CQR conferring mutant pfcrt gene. We also analyze the rate of Hz growth in the presence and absence of physiologically relevant doses of chloroquine (CQ) and verapamil (VPL) and thereby present the first in vivo quantification of key predictions from the well-known Fitch hypothesis for CQ pharmacology. In the following paper [Gligorijevic, B., et al. (2006) Biochemistry 45, pp 12411-12423], we acquire fluorescent images of live parasite DV via SDCM and use those to quantify DV volume for CQS versus CQR parasites.  相似文献   

19.
Mitosis in Aspergillus nidulans is very rapid, requiring less than 5 min at 37 °C in germlings (Bergen and Morris, 1983). In this time the cytoplasmic microtubules (MTs) must disassemble, the mitotic spindle assemble, function and disassemble, and cytoplasmic MTs reassemble. It follows that cytoplasmic MTs must be extremely dynamic in this period and we were interested, in particular, in examining the processes of MT disassembly in prophase and reassembly in anaphase and telophase. We observed a diploid strain that expressed GFP-α-tubulin. We used a spinning disk confocal microscope that allowed rapid image capture, which proved necessary because microtubule dynamics were extremely rapid. We found, for the first time, that microtubule severing occurs in prophase in a filamentous fungus and that catastrophe rather than nucleation limits astral microtubule growth.  相似文献   

20.
We report methodological advances that extend the current capabilities of ion-abrasion scanning electron microscopy (IA-SEM), also known as focused ion beam scanning electron microscopy, a newly emerging technology for high resolution imaging of large biological specimens in 3D. We establish protocols that enable the routine generation of 3D image stacks of entire plastic-embedded mammalian cells by IA-SEM at resolutions of ∼10–20 nm at high contrast and with minimal artifacts from the focused ion beam. We build on these advances by describing a detailed approach for carrying out correlative live confocal microscopy and IA-SEM on the same cells. Finally, we demonstrate that by combining correlative imaging with newly developed tools for automated image processing, small 100 nm-sized entities such as HIV-1 or gold beads can be localized in SEM image stacks of whole mammalian cells. We anticipate that these methods will add to the arsenal of tools available for investigating mechanisms underlying host-pathogen interactions, and more generally, the 3D subcellular architecture of mammalian cells and tissues.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏