首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The objectives of this study were to determine the longitudinal and transverse material properties of the human medial collateral ligament (MCL) and to evaluate the ability of three existing constitutive models to describe the material behavior of MCL. Uniaxial test specimens were punched from ten human cadaveric MCLs and tensile tested along and transverse to the collagen fiber direction. Using load and optical strain analysis information, the tangent modulus, tensile strength and ultimate strain were determined. The material coefficients for each constitutive model were determined using nonlinear regression. All specimens failed within the substance of the tissue. Specimens tested along the collagen fiber direction exhibited the typical nonlinear behavior reported for ligaments. This behavior was absent from the stress-strain curves of the transverse specimens. The average tensile strength, ultimate strain, and tangent modulus for the longitudinal specimens was 38.6 +/- 4.8 MPa, 17.1 +/- 1.5 percent, and 332.2 +/- 58.3 MPa, respectively. The average tensile strength, ultimate strain, and tangent modulus for the transverse specimens was 1.7 +/- 0.5 MPa, 11.7 +/- 0.9 percent, and 11.0 +/- 3.6 MPa, respectively. All three constitutive models described the longitudinal behavior of the ligament equally well. However, the ability of the models to describe the transverse behavior of the ligament varied.  相似文献   

2.
The objective of this study was to determine the mechanical properties of the axillary pouch of the inferior glenohumeral ligament in the directions perpendicular (transverse) and parallel (longitudinal) to the longitudinal axis of the anterior band of the inferior glenohumeral ligament. A punch was used to excise one transverse and one longitudinal tissue sample from the axillary pouch of each cadaveric shoulder (n = 10). Each tissue sample was preconditioned and then a load-to-failure test was performed. All tissue samples exhibited the typical nonlinear behavior reported for ligaments and tendons. Significant differences (p < 0.05) were detected between the transverse and longitudinal tissue samples for ultimate stress (0.8 +/- 0.4 MPa and 2.0 +/- 1.0 MPa, respectively) and tangent modulus (5.4 +/- 2.9 MPa and 14.8 +/- 13.1 MPa, respectively). No significant differences (p > 0.05) were observed between the ultimate strain (transverse: 23.5 +/- 11.5%, longitudinal: 33.3 +/- 23.6%) and strain energy density (transverse: 10.8 +/- 8.5 MPa, longitudinal: 21.1 +/- 15.4 MPa) of the transverse and longitudinal tissue samples. The ultimate stress determined for the longitudinal axillary pouch tissue samples was comparable to a previous study that reported it to be 5.5 +/- 2.0 MPa. The ratio of the longitudinal to transverse moduli (3.3 +/- 2.8) is considerably less than that of the medial collateral ligament of the knee (30) and interosseous ligament of the forearm (385), suggesting that the axillary pouch functions to stabilize the joint in more than just one direction. Future models of the glenohumeral joint and surgical repair procedures should consider the properties of the axillary pouch in its transverse and longitudinal directions to fully describe the behavior of the inferior glenohumeral ligament.  相似文献   

3.
The objective of this study was to determine the mechanical properties of the posterior region of the glenohumeral capsule in the directions perpendicular (transverse) and parallel (longitudinal) to the longitudinal axis of the posterior band of the inferior glenohumeral ligament. A punch was used to excise one transverse and one longitudinal tissue sample from the posterior capsule of 11 cadaveric shoulders. All tissue samples exhibited the typical nonlinear behavior reported for ligaments and tendons. Significant differences (p < 0.05) were detected between the transverse and longitudinal tissue samples for ultimate stress (1.5+/-1.4 and 4.9+/-2.9 MPa, respectively) and tangent modulus (10.3+/-6.6 and 31.5+/-12.7 MPa, respectively). No significant differences (p > 0.05) were observed between the ultimate strain (transverse: 22.3+/-12.5%, longitudinal: 22.8+/-11.1%) and strain energy density (transverse: 27.2+/-52.8 MPa, longitudinal: 67.5+/-88.2 MPa) of the transverse and longitudinal tissue samples. The ratio of the longitudinal to transverse moduli (4.8+/-4.2) was similar to that found for the axillary pouch (3.3+/-2.8) in a previous study. Thus, both the axillary pouch and the posterior capsule function to stabilize the joint multi-axially. Future analytical models of the glenohumeral joint should consider the properties of the posterior capsule in its transverse and longitudinal directions to fully describe the behavior of the glenohumeral capsule. These models will be clinically important by providing a more accurate representation of the intact capsule as well as simulated capsular injuries and surgical repair procedures.  相似文献   

4.
Mechanical properties of metaphyseal bone in the proximal femur   总被引:4,自引:1,他引:3  
We used a three-point bending test to investigate the structural behavior of 123 rectangular flat plate specimens harvested from the metaphyseal shell of the cervical and intertrochanteric regions of five fresh/frozen human proximal femora. For comparison purposes, 36 specimens of similar geometry were also fabricated from bone of the femoral diaphysis. All specimens were oriented in either the local longitudinal or transverse directions. The mean longitudinal elastic modulus was 9650 +/- 2410 (SD) MPa and demonstrated a 24% decrease from that measured for the diaphysis (12500 +/- 2140 MPa) using the same testing technique. However, the transverse elastic moduli did not differ significantly between the proximal (5470 +/- 1720 MPa) and diaphyseal (5990 +/- 1520 MPa) specimens. The globally averaged values for the ultimate tensile strengths of the metaphyseal shell were 101 +/- 26 MPa in the longitudinal and 50 +/- 12 MPa in the transverse directions. These compared with diaphyseal values of 128 +/- 16 MPa and 47 +/- 12 MPa, respectively. While these differences were largely due to the reduced density of the proximal specimens, a slight decrease in transverse anisotropy for the proximal specimens was also noted by comparing the ratio of longitudinal to transverse moduli (1.76) and tensile strength (2.02) to the diaphyseal values (2.09 and 2.71, respectively). Use of these data should lead to improved performance of analytical models for the proximal femur, and thus help focus increased attention on the structural contribution of trabecular bone to the strength and rigidity of the proximal femur.  相似文献   

5.
Samples of male and female mice skin were tested under monotonic and cyclic loading to mechanically characterize the tissue for large deformations. Cyclic tests have shown a typical Mullins effect widely known for elastomers and other soft tissues. No statistical difference was found in the maximum stretch of the sample after the fifth loading cycle for male (1.26 +/- 0.035) and female (1.18 +/- 0.083). However, larger dispersion was obtained for the maximum stress for both genders, 0.61 +/- 0.16 MPa for male and 0.78 +/- 0.32 MPa for female. Results show the presence of inelastic strain and stress softening in the skin at large deformations. They also have shown how stress softening and residual strain change with the magnitude of the applied load. Good correlation was observed between the residual strain and the maximum strain previously attained by the sample during loading for all samples. However, the correlation was different between genders.  相似文献   

6.
Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The purpose of this study was to use imaging techniques to measure the strains around the circumference of 11 mm wide Achilles tendon grafts during a uniaxial tensile test. Pairs of radiopaque beads with a diameter of 2mm were affixed around the mid-substance of the tendon in four different locations. The motion of the beads was recorded using a cine fluoroscope. This system was shown to measure the displacement of the beads with an accuracy of 0.02 mm. During the uniaxial tensile test, large variations in local tissue strains were observed. At 10 MPa of applied stress, the local tissue strain varied from an average of 2.5-8.7%, an increase in strain of more than three times. As a result of these large variations, the modulus calculated from the stress-strain data varied from an average of 217 to 897 MPa, an increase of approximately 4 times. Furthermore, these data suggest that underestimates of the elastic modulus may result if a uniform strain distribution is assumed. These results indicate that during uniaxial tensile tests, the assumption of uniform stress and strain distributions should be carefully considered and small, uniform specimens should be used when measuring the material properties of soft tissues.  相似文献   

7.
Mechanics of carpal tunnel soft tissue, such as fat, muscle and transverse carpal ligament (TCL), around the median nerve may render the median nerve vulnerable to compression neuropathy. The purpose of this study was to understand the roles of carpal tunnel soft tissue mechanical properties and intratunnel pressure on the TCL tensile strain and carpal arch area (CAA) using finite element analysis (FEA). Manual segmentation of the thenar muscles, skin, fat, TCL, hamate bone, and trapezium bone in the transverse plane at distal carpal tunnel were obtained from B-mode ultrasound images of one cadaveric hand. Sensitivity analyses were conducted to examine the dependence of TCL tensile strain and CAA on TCL elastic modulus (0.125–10 MPa volar-dorsally; 1.375–110 MPa transversely), skin-fat and thenar muscle initial shear modulus (1.6–160 kPa for skin-fat; 0.425–42.5 kPa for muscle), and intratunnel pressure (60–480 mmHg). Predictions of TCL tensile strain under different intratunnel pressures were validated with the experimental data obtained on the same cadaveric hand. Results showed that skin, fat and muscles had little effect on the TCL tensile strain and CAA changes. However, TCL tensile strain and CAA increased with decreased elastic modulus of TCL and increased intratunnel pressure. The TCL tensile strain and CAA increased linearly with increased pressure while increased exponentially with decreased elastic modulus of TCL. Softening the TCL by decreasing the elastic modulus may be an alternative clinical approach to carpal tunnel expansion to accommodate elevated intratunnel pressure and alleviate median nerve compression neuropathy.  相似文献   

8.
At autopsy, 13 nonstenotic human left anterior descending coronary arteries [71.5 +/- 7.3 (mean +/- SD) yr old] were harvested, and related anamnesis was documented. Preconditioned prepared strips (n = 78) of segments from the midregion of the left anterior descending coronary artery from the individual layers in axial and circumferential directions were subjected to cyclic quasi-static uniaxial tension tests, and ultimate tensile stresses and stretches were documented. The ratio of outer diameter to total wall thickness was 0.189 +/- 0.014; ratios of adventitia, media, and intima thickness to total wall thickness were 0.4 +/- 0.03, 0.36 +/- 0.03, and 0.27 +/- 0.02, respectively; axial in situ stretch of 1.044 +/- 0.06 decreased with age. Stress-stretch responses for the individual tissues showed pronounced mechanical heterogeneity. The intima is the stiffest layer over the whole deformation domain, whereas the media in the longitudinal direction is the softest. All specimens exhibited small hysteresis and anisotropic and strong nonlinear behavior in both loading directions. The media and intima showed similar ultimate tensile stresses, which are on average three times smaller than ultimate tensile stresses in the adventitia (1,430 +/- 604 kPa circumferential and 1,300 +/- 692 kPa longitudinal). The ultimate tensile stretches are similar for all tissue layers. A recently proposed constitutive model was extended and used to represent the deformation behavior for each tissue type over the entire loading range. The study showed the need to model nonstenotic human coronary arteries with nonatherosclerotic intimal thickening as a composite structure composed of three solid mechanically relevant layers with different mechanical properties. The intima showed significant thickness, load-bearing capacity, and mechanical strength compared with the media and adventitia.  相似文献   

9.
As local drug delivery continues to emerge as a clinical force, so does understanding of its potentially narrow therapeutic window. Classic molecular transport studies are of value but do not typically account for the local nature of drug transport or the effects of regional dynamic function in target tissues like muscle that may undergo cyclical and variable mechanical motion and loading. We examined the impact of dynamic architecture on intramuscular drug distribution. We designed a tissue mounting technique and mechanical loading system that uniquely enables pharmacokinetics investigations in association with control of muscle biomechanics while preserving physiologic tissue architecture. The system was validated and used to elucidate the influence of architecture and controlled cyclic strain on intramuscular drug distribution. Rat soleus muscles underwent controlled deformations within a drug delivery chamber that preserved in vivo physiology. Penetration of 1mM 20kDa FITC-dextran at planar surfaces of the soleus axial cross-section increased significantly from 0.52+/-0.09mm under 80min of static (0%) strain to 0.81+/-0.09mm under cyclic (3Hz, 0-20% peak-to-peak) strain, demonstrating the driving effect of cyclic loading on transport. Penetration at curved margins was 1.57- and 2.53-fold greater than at planar surfaces under static and cyclic strain, respectively, and was enhanced 1.6-fold more by cyclic strain, revealing architecturally dictated spatial heterogeneity in transport and modulation of motion dynamics. Architectural geometry and dynamics modulate the impact of mechanical loading on local drug penetration and intramuscular distribution. Future work will use the biomechanical test system to investigate mechanisms underlying transport effects of specific loading regimens. It is hoped that this work will initiate a broader understanding of intramuscular pharmacokinetics and guide local drug delivery strategies.  相似文献   

10.

Introduction

Though xenogeneic acellular scaffolds are frequently used for surgical reconstruction, knowledge of their mechanical properties is lacking. This study compared the mechanical, histological and ultrastructural properties of various native and acellular specimens.

Materials and Methods

Porcine esophagi, ureters and skin were tested mechanically in a native or acellular condition, focusing on the elastic modulus, ultimate tensile stress and maximum strain. The testing protocol for soft tissues was standardized, including the adaption of the tissue’s water content and partial plastination to minimize material slippage as well as templates for normed sample dimensions and precise cross-section measurements. The native and acellular tissues were compared at the microscopic and ultrastructural level with a focus on type I collagens.

Results

Increased elastic modulus and ultimate tensile stress values were quantified in acellular esophagi and ureters compared to the native condition. In contrast, these values were strongly decreased in the skin after acellularization. Acellularization-related decreases in maximum strain were found in all tissues. Type I collagens were well-preserved in these samples; however, clotting and a loss of cross-linking type I collagens was observed ultrastructurally. Elastins and fibronectins were preserved in the esophagi and ureters. A loss of the epidermal layer and decreased fibronectin content was present in the skin.

Discussion

Acellularization induces changes in the tensile properties of soft tissues. Some of these changes appear to be organ specific. Loss of cross-linking type I collagen may indicate increased mechanical strength due to decreasing transverse forces acting upon the scaffolds, whereas fibronectin loss may be related to decreased load-bearing capacity. Potentially, the alterations in tissue mechanics are linked to organ function and to the interplay of cells and the extracellular matrix, which is different in hollow organs when compared to skin.  相似文献   

11.
Mechanical deformation applied at the joint or tissue level is transmitted through the macroscale extracellular matrix to the microscale local matrix, where it is transduced to cells within these tissues and modulates tissue growth, maintenance, and repair. The objective of this study was to investigate how applied tissue strain is transferred through the local matrix to the cell and nucleus in meniscus, tendon, and the annulus fibrosus, as well as in stem cell-seeded scaffolds engineered to reproduce the organized microstructure of these native tissues. To carry out this study, we developed a custom confocal microscope-mounted tensile testing device and simultaneously monitored strain across multiple length scales. Results showed that mean strain was heterogeneous and significantly attenuated, but coordinated, at the local matrix level in native tissues (35–70% strain attenuation). Conversely, freshly seeded scaffolds exhibited very direct and uniform strain transfer from the tissue to the local matrix level (15–25% strain attenuation). In addition, strain transfer from local matrix to cells and nuclei was dependent on fiber orientation and tissue type. Histological analysis suggested that different domains exist within these fibrous tissues, with most of the tissue being fibrous, characterized by an aligned collagen structure and elongated cells, and other regions being proteoglycan (PG)-rich, characterized by a dense accumulation of PGs and rounder cells. In meniscus, the observed heterogeneity in strain transfer correlated strongly with cellular morphology, where rounder cells located in PG-rich microdomains were shielded from deformation, while elongated cells in fibrous microdomains deformed readily. Collectively, these findings suggest that different tissues utilize distinct strain-attenuating mechanisms according to their unique structure and cellular phenotype, and these differences likely alter the local biologic response of such tissues and constructs in response to mechanical perturbation.  相似文献   

12.
Nanofibrous biocomposite scaffolds of type I collagen and nanohydroxyapatite (nanoHA) of varying compositions (wt %) were prepared by electrostatic cospinning. The scaffolds were characterized for structure and morphology by Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), atomic force microscopy (AFM) and X-ray diffraction (XRD) techniques. The scaffolds have a porous nanofibrous morphology with random fibers in the range of 500-700 nm diameters, depending on the composition. FT-IR and XRD showed the presence of nanoHA in the fibers. The surface roughness and diameter of the fibers increased with the presence of nanoHA in biocomposite fiber as evident from AFM images. Tensile testing and nanoindendation were used for the mechanical characterization. The pure collagen fibrous matrix (without nanoHA) showed a tensile strength of 1.68 +/- 0.10 MPa and a modulus of 6.21 +/- 0.8 MPa with a strain to failure value of 55 +/- 10%. As the nanoHA content in the randomly oriented collagen nanofibers increased to 10%, the ultimate strength increased to 5 +/- 0.5 MPa and the modulus increased to 230 +/- 30 MPa. The increase in tensile modulus may be attributed to an increase in rigidity over the pure polymer when the hydroxyapatite is added and/or the resulting strong adhesion between the two materials. The vapor phase chemical crosslinking of collagens using glutaraldehyde further increased the mechanical properties as evident from nanoindentation results. A combination of nanofibrous collagen and nanohydroxyapatite that mimics the nanoscale features of the extra cellular matrix could be promising for application as scaffolds for hard tissue regeneration, especially in low or nonload bearing areas.  相似文献   

13.
Mechanical deformation applied at the joint or tissue level is transmitted through the macroscale extracellular matrix to the microscale local matrix, where it is transduced to cells within these tissues and modulates tissue growth, maintenance, and repair. The objective of this study was to investigate how applied tissue strain is transferred through the local matrix to the cell and nucleus in meniscus, tendon, and the annulus fibrosus, as well as in stem cell-seeded scaffolds engineered to reproduce the organized microstructure of these native tissues. To carry out this study, we developed a custom confocal microscope-mounted tensile testing device and simultaneously monitored strain across multiple length scales. Results showed that mean strain was heterogeneous and significantly attenuated, but coordinated, at the local matrix level in native tissues (35–70% strain attenuation). Conversely, freshly seeded scaffolds exhibited very direct and uniform strain transfer from the tissue to the local matrix level (15–25% strain attenuation). In addition, strain transfer from local matrix to cells and nuclei was dependent on fiber orientation and tissue type. Histological analysis suggested that different domains exist within these fibrous tissues, with most of the tissue being fibrous, characterized by an aligned collagen structure and elongated cells, and other regions being proteoglycan (PG)-rich, characterized by a dense accumulation of PGs and rounder cells. In meniscus, the observed heterogeneity in strain transfer correlated strongly with cellular morphology, where rounder cells located in PG-rich microdomains were shielded from deformation, while elongated cells in fibrous microdomains deformed readily. Collectively, these findings suggest that different tissues utilize distinct strain-attenuating mechanisms according to their unique structure and cellular phenotype, and these differences likely alter the local biologic response of such tissues and constructs in response to mechanical perturbation.  相似文献   

14.
15.
This study examined the effect of loading (displacement) rate on the tensile mechanics of cervical spine functional spinal units. A total of 40 isolated functional spinal units (two vertebrae and the adjoining soft tissues) from juvenile male baboons (10+/-0.6-human equivalent years old) were subjected to tensile loading spanning four orders of magnitude from 0.5 to 5000 mm/s. The stiffness, ultimate failure load, and corresponding displacement at failure were measured for each specimen and normalized by spinal geometry to examine the material properties as well as the structural properties. The tensile stiffness, failure load, normalized stiffness, and normalized failure load significantly increased (ANOVA, p<0.001) with increasing displacement rate. From the slowest to fastest loading rate, a two-fold increase in stiffness and four-fold increase in failure load were observed. The tensile failure strains (1.07+/-0.31 mm/mm strain) were not significantly correlated with loading rate (ANOVA, p=0.146). Both the functional (non-destructive stiffness and normalized stiffness) and failure mechanics of isolated functional spinal units exhibited a power-law relationship with displacement rate. Modeling efforts utilizing these rate-dependent characteristics will enhance our understanding of the tensile viscoelastic response of the spine and enable improved dynamic injury prevention schemes.  相似文献   

16.
Quantification of the mechanical behavior of soft tissues is challenging due to their anisotropic, heterogeneous, and nonlinear nature. We present a method for the ‘computational dissection’ of a tissue, by which we mean the use of computational tools both to identify and to analyze regions within a tissue sample that have different mechanical properties. The approach employs an inverse technique applied to a series of planar biaxial experimental protocols. The aggregated data from multiple protocols provide the basis for (1) segmentation of the tissue into regions of similar properties, (2) linear analysis for the small-strain behavior, assuming uniform, linear, anisotropic behavior within each region, (3) subsequent nonlinear analysis following each individual experimental protocol path and using local linear properties, and (4) construction of a strain energy data set W(E) at every point in the material by integrating the differential stress–strain functions along each strain path. The approach has been applied to simulated data and captures not only the general nonlinear behavior but also the regional differences introduced into the simulated tissue sample.  相似文献   

17.
Arterial subfailure leads to delayed symptomatology and high morbidity and mortality rates, particularly for the thoracic aorta and carotid arteries. Although arterial injuries occur during high-velocity automotive collisions, previous studies of arterial subfailure focused on quasi-static loading. This investigation subjected aortic segments to increasing loading rates to quantify effects on elastic, subfailure, and ultimate vessel mechanics. Sixty-two specimens were axially distracted, and 92% demonstrated subfailure before ultimate failure. With increasing loading rate, stress at initial subfailure and ultimate failure significantly increased, and strain at initial subfailure and ultimate failure significantly decreased. Present results indicate increased susceptibility for arterial subfailure and/or dissection under higher-rate extension. According to the present results, automotive occupants are at greater risk of arterial injury under higher velocity impacts due to greater body segment motions in addition to decreased strain tolerance to subfailure and catastrophic failure.  相似文献   

18.
The objective of this study was to assess the precision and accuracy of a nonproprietary, optical three-dimensional (3D) motion analysis system for the simultaneous measurement of soft tissue strains and joint kinematics. The system consisted of two high-resolution digital cameras and software for calculating the 3D coordinates of contrast markers. System precision was assessed by examining the variation in the coordinates of static markers over time. Three-dimensional strain measurement accuracy was assessed by moving contrast markers fixed distances in the field of view and calculating the error in predicted strain. Three-dimensional accuracy for kinematic measurements was assessed by simulating the measurements that are required for recording knee kinematics. The field of view (190 mm) was chosen to allow simultaneous recording of markers for soft tissue strain measurement and knee joint kinematics. Average system precision was between +/-0.004 mm and +/-0.035 mm, depending on marker size and camera angle. Absolute error in strain measurement varied from a minimum of +/-0.025% to a maximum of +/-0.142%, depending on the angle between cameras and the direction of strain with respect to the camera axes. Kinematic accuracy for translations was between +/-0.008 mm and +/-0.034 mm, while rotational accuracy was +/-0.082 deg to +/-0.160 deg. These results demonstrate that simultaneous optical measurement of 3D soft tissue strain and 3D joint kinematics can be performed while achieving excellent accuracy for both sets of measurements.  相似文献   

19.
The heterogeneous composition and mechanical properties of the supraspinatus tendon offer an opportunity for studying the structure-function relationships of fibrous musculoskeletal connective tissues. Previous uniaxial testing has demonstrated a correlation between the collagen fiber angle distribution and tendon mechanics in response to tensile loading both parallel and transverse to the tendon longitudinal axis. However, the planar mechanics of the supraspinatus tendon may be more appropriately characterized through biaxial tensile testing, which avoids the limitation of nonphysiologic traction-free boundary conditions present during uniaxial testing. Combined with a structural constitutive model, biaxial testing can help identify the specific structural mechanisms underlying the tendon's two-dimensional mechanical behavior. Therefore, the objective of this study was to evaluate the contribution of collagen fiber organization to the planar tensile mechanics of the human supraspinatus tendon by fitting biaxial tensile data with a structural constitutive model that incorporates a sample-specific angular distribution of nonlinear fibers. Regional samples were tested under several biaxial boundary conditions while simultaneously measuring the collagen fiber orientations via polarized light imaging. The histograms of fiber angles were fit with a von Mises probability distribution and input into a hyperelastic constitutive model incorporating the contributions of the uncrimped fibers. Samples with a wide fiber angle distribution produced greater transverse stresses than more highly aligned samples. The structural model fit the longitudinal stresses well (median R(2) ≥ 0.96) and was validated by successfully predicting the stress response to a mechanical protocol not used for parameter estimation. The transverse stresses were fit less well with greater errors observed for less aligned samples. Sensitivity analyses and relatively affine fiber kinematics suggest that these errors are not due to inaccuracies in measuring the collagen fiber organization. More likely, additional strain energy terms representing fiber-fiber interactions are necessary to provide a closer approximation of the transverse stresses. Nevertheless, this approach demonstrated that the longitudinal tensile mechanics of the supraspinatus tendon are primarily dependent on the moduli, crimp, and angular distribution of its collagen fibers. These results add to the existing knowledge of structure-function relationships in fibrous musculoskeletal tissue, which is valuable for understanding the etiology of degenerative disease, developing effective tissue engineering design strategies, and predicting outcomes of tissue repair.  相似文献   

20.
Accidentology data showed that liver is often injured in car crashes; three types of injuries occur: hematoma, laceration and vessel failure. This paper focuses on surface laceration, which involves liver capsule and hepatic parenchyma. Liver capsule behavior has been studied but its failure properties are still unclear, particularly on a local point of view. In the present study, tensile quasi-static tests are run on parenchyma and capsule samples until failure to characterize capsule failure. Normalized load as well as failure properties—ultimate load per width unit and ultimate strain—are determined. Digital image correlation is used to measure the full local strain field on the capsule. Mean values of failure characteristics for hepatic capsule are 47±29% for the ultimate local strain and 0.3±0.3 N/mm for the ultimate load per width unit. A comparison between human and porcine tissues is conducted based on Mann–Whitney statistical test; it reveals that capsule characteristics are close between these two species; however, freezing preservation significantly affects porcine capsule failure properties. Therefore using porcine instead of human tissue to determine failure characteristics of liver capsule seems satisfactory only on fresh tissues.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号