首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Three extraction procedures were developed for the quantitative determination of a carboxylic acid containing analyte (I) in human plasma by high-performance liquid chromatography (HPLC) with negative ion electrospray tandem mass spectrometry (MS–MS). The first procedure was based on the manual liquid–liquid extraction (LLE) of the acidified plasma samples with methyl tert.-butyl ether. The second procedure was based on the automation of the manual LLE procedure using 96-well collection plates and a robotic liquid handling system. The third approach was based on automated solid-phase extraction (SPE) using 96-well SPE plates and a robotic liquid handling system. A lower limit of quantitation of 50 pg/ml was achieved using all three extraction procedures. The total time required to prepare calibration curve standards, aliquot the standards and plasma samples, and process a total of 96 standards and samples by manual LLE was three-times longer than the time required for 96-well SPE or 96-well LLE (4 h, 50 min vs. 1 h, 43 min). Even more importantly, the time the bioanalyst physically spent on the 96-well LLE or 96-well SPE procedure was only a small fraction of the time spent on the manual LLE procedure (<10 min vs. 4 h, 10 min). It should be noted that the 96-well SPE procedure incorporated the two steps of evaporation of the eluates to dryness and subsequent reconstitution of the dried extract. The total time required for the 96-well SPE could be reduced by 50% if the eluates were injected directly, eliminating the drying and reconstitution steps, which is achievable when sensitivity is less of an issue.  相似文献   

2.
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography–negative chemical ionization tandem mass spectrometry (GC–NCI-MS–MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC–NCI-MS–MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90–106% with a precision of 2.4–12.9%.  相似文献   

3.
F(2)-isoprostanes (F(2)-iPs), established markers of oxidative stress, exist as four sets of regioisomers. Simultaneous and specific determination of F(2)-iPs can be achieved by liquid chromatography-tandem mass spectrometry (LC-MS/MS). We developed novel methods for urine sample preparation and HPLC to control matrix-related ion suppression effects in the LC-MS/MS analysis of F(2)-iPs. A selective solid-phase extraction (SPE) wash protocol was developed with an Oasis HLB (hydrophilic-lipophilic balance) SPE cartridge using an elution profile of [(3)H]8-iso-prostaglandin (PG)F(2alpha) (iPF(2alpha)-III) when the methanol concentration was increased under acidic, neutral, and base wash conditions. A multidimensional (MD)-SPE method that incorporated size exclusion chromatography [corrected] reverse-phase chromatography, and normal-phase chromatography was developed using an Oasis HLB SPE cartridge and an HLB microElution SPE plate. Average extraction recoveries of the deuterated internal standards of iPF(2alpha)-III and iPF(2alpha)-VI were 62 +/- 8% and 60 +/- 10%. A buffer-free HPLC method for the separation of F(2)-iP isomers was developed on base-deactivated C8 columns. Average matrix effects for iPF(2alpha)-III and iPF(2alpha)-VI were 95 +/- 6% and 103 +/- 5%. The clean extraction of urine F(2)-iPs using MD-SPE and the separation of F(2)-iP isomers using a novel HPLC method did not cause apparent ion suppression in the analysis of iPF(2alpha)-III and iPF(2alpha)-VI using LC-MS/MS. These findings should be useful for establishing a routine LC-MS/MS method for the analysis of F(2)-iPs.  相似文献   

4.
In order to overcome many limitations of immunoassays, high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has the potential to find its place in the clinical laboratory medicine for quantification of steroid hormones. A prerequisite for the application of a new analytical procedure in clinical diagnostics is standardization to minimize analytical intra- and interlaboratory variability and inaccuracy. We evaluate a newly standardized HPLC-MS/MS assay in kit-format, developed for routine determination of 16 steroid hormones in human serum samples. Fifteen metabolites can be measured quantitatively, which include aldosterone, androstenedione, androsterone, corticosterone, cortisol, cortisone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), 17β-estradiol (E2), estrone (E1), etiocholanolone, 17α-hydroxyprogesterone (17OHP), progesterone, and testosterone. 11-Deoxycorticosterone is the only compound rated as semi-quantitative in this kit. The sample preparation is performed by solid phase extraction (SPE) on a 96-well plate. The standardized assay has been validated for human serum in terms of lower and upper limit of quantification (LLOQ 0.01-32 ng/mL, ULOQ 5-8000 ng/mL), linear correlation coefficient of calibration (R(2)>0.9966), intra- and inter-day precision (intra-day 1.1-8.8%, inter-day 5.2-14.8% and 8.2-18.6% for 11-deoxycorticosterone), accuracy (intra-day 88.3-115.5% and 109.3-128.2% for 11-deoxycorticosterone, inter-day 91.4-117.2% and 102.3-137.1% for 11-deoxycorticosterone), analytical total error (3.6-17.8%), proficiency test accuracy (85.4-113.4%), recovery (68-99%), and metabolite stability (freeze/thaw stability 95.5-108.1%, short term stability 86.9-107.2%). Inter-assay comparison with a routine reference HPLC-MS/MS assay and seven immunoassays demonstrates the outstanding high performance of this HPLC-MS/MS based kit by improvements in accuracy for progesterone, androstenedione, and 17OHP. Finally, results of two metyrapone tests demonstrate the potential of the standardized HPLC-MS/MS assay for the analysis of a comprehensive steroid hormone profile in clinical diagnostics.  相似文献   

5.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

6.
A systematic, comprehensive strategy that optimizes sample preparation and chromatography to minimize matrix effects in bioanalytical LC/MS/MS assays was developed. Comparisons were made among several sample preparation methods, including protein precipitation (PPT), liquid-liquid extraction (LLE), pure cation exchange solid-phase extraction (SPE), reversed-phase SPE and mixed-mode SPE. The influence of mobile phase pH and gradient duration on the selectivity and sensitivity for both matrix components and basic analytes was investigated. Matrix effects and overall sensitivity and resolution between UPLC technology and HPLC were compared. The amount of specific matrix components, or class of matrix components, was measured in the sample preparation extracts by LC/MS/MS with electrospray ionization (ESI) using both precursor ion scanning mode and multiple reaction monitoring (MRM). PPT is the least effective sample preparation technique, often resulting in significant matrix effects due to the presence of many residual matrix components. Reversed-phase and pure cation exchange SPE methods resulted in cleaner extracts and reduced matrix effects compared to PPT. The cleanest extracts, however, were produced with polymeric mixed-mode SPE (both reversed-phase and ion exchange retention mechanisms). These mixed-mode sorbents dramatically reduced the levels of residual matrix components from biological samples, leading to significant reduction in matrix effects. LLE also provided clean final extracts. However, analyte recovery, particularly for polar analytes, was very low. Mobile phase pH was manipulated to alter the retention of basic compounds relative to phospholipids, whose retention tends to be relatively independent of pH. In addition to the expected resolution, speed and sensitivity benefits of UPLC technology, a paired t-test demonstrated a statistically significant improvement with respect to matrix effects when this technology was chosen over traditional HPLC. The combination of polymeric mixed-mode SPE, the appropriate mobile phase pH and UPLC technology provides significant advantages for reducing matrix effects resulting from plasma matrix components and in improving the ruggedness and sensitivity of bioanalytical methods.  相似文献   

7.
A sensitive and high throughput off-line μElution 96-well solid-phase extraction (SPE) followed by strong cation exchange (SCX) liquid chromatography with tandem mass spectrometry (LC/MS/MS) quantification for determination of cefepime has been developed and validated in mouse plasma. Using the chemical analog, ceftazidime as an internal standard (IS), the linear range of the method for the determination of cefepime in mouse plasma was 4–2048 ng/mL with the lower limit of quantitation level (LLOQ) of 4 ng/mL. The inter- and intra-assay precision and accuracy of the method were below 9.05% and ranged from 95.6 to 113%, respectively, determined by quality control (QC) samples at five concentration levels including LLOQ. After μElution SPE, 71.1% of cefepime was recovered. The application of the validated assay for the determination of cefepime in mouse pharmacokinetics (PK) samples after intravenous (IV) and subcutaneous (SC) doses was demonstrated.  相似文献   

8.
A method for the determination of a prostaglandin D(2) receptor antagonist (I, a compound being evaluated for the prevention of niacin induced flushing) and its acyl glucuronide metabolite (II) in human plasma is presented. The method utilized high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection using an atmospheric pressure chemical ionization (APCI) interface operated in the positive ionization mode. The product ion was a radical cation generated via a homolytic bond cleavage. A chemical analog of the drug was used as internal standard (III). The acyl glucuronide metabolite (II) was detected using the same precursor-to-product ion transition used for the parent compound after chromatographic separation of I and II. Drug and metabolite were extracted using semi-automated, 96-well format solid phase extraction (SPE), and chromatography was performed using a reverse phase analytical column with an isocratic mobile phase. The chromatographic retention factor (k') of II was found to be highly sensitive to mobile phase formic acid concentration. An adjustment in mobile phase formic acid concentration improved the chromatographic separation between II and a mono-hydroxylated metabolite after an unexpected lack of MS/MS selectivity between the two molecules was observed. The dependence of retention factor on formic acid concentration (k' increased as formic acid concentration decreased) was thought to indicate polar interactions between II and the stationary phase. The stability of II in spiked human plasma was determined. The rate of hydrolysis back to parent compound was relatively low (approximately 0.1 and 0.5% per hour at room temperature and 4 degrees C, respectively) indicating that significant changes in analyte concentrations did not occur during sample processing. The concentration range of the assay was 10-2500 ng/mL for both drug and glucuronide metabolite.  相似文献   

9.
A high throughput preparation method for the determination of trileptal (oxcarbazepine, OXC) and its mono (MHD) and dihydroxy (DHD) metabolites in human plasma, using 96-well plate technology, has been developed and validated according to international regulatory requirements. Preparation of plasma samples (50 μl) containing the compounds to be analysed involved solid-phase extraction (SPE) on Empore C18 96-well SPE plates. Eluates from the plate were injected onto a reversed-phase column (Hypersil C18, 3 μm) with UV detection at 210 nm. Detector response was linear over the ranges 0.2–10, 0.1–200 and 0.1–20 μmol/l, for OXC, MHD and DHD, respectively, with relative standard deviations from 1 to 10% and mean accuracies within 4% of the nominal values (number of standard curves=3 in duplicate). The limits of quantitation were 0.2, 0.1 and 0.1 μmol/l, respectively. The overall mean accuracies ranged from 96 to 106% and precision was in the range 4 to 11%. Cross validation indicated no significant difference between plasma concentrations obtained using the 96-well method and the previous method using a traditional SPE method with a 50 mg C18 cartridge. About a threefold increase in sample throughput and a twofold decrease of plasma volume required for the assays, were the main advantages obtained from the previous method. The method was applied for the determination of 3000 plasma samples from clinical studies.  相似文献   

10.
To support toxicokinetic assessments, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of BMS-790052 in rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. The drug was isolated from buffered samples using ISOLUTE C8 96-well solid phase extraction (SPE) plates. Chromatographic separation was achieved on a Waters Atlantis dC18 analytical column (2.1 mm × 50 mm, 5 μm) with detection accomplished using an API 4000 tandem mass spectrometer in positive ion electrospray and multiple reaction monitoring (MRM) mode. The standard curves, which ranged from 5.00 to 2000 ng/mL for BMS-790052, were fitted to a 1/x(2) weighted linear regression model. The intra-assay precision (%CV) and inter-assay precision (%CV) were within 8.5%, and the assay accuracy (%Dev) was within ±7.1 for rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. This accurate, precise, and selective SPE/LC-MS/MS method has been successfully applied to analyze several thousands of non-clinical study samples.  相似文献   

11.
Phytoestrogens are currently the subject of intense study owing to their potential protective effects against a number of complex diseases. However, in order to investigate the interactions between phytoestrogens and disease state effectively, it is necessary to have analytical methods which are sensitive, reproducible, and require low sample volumes. We report an assay for three isoflavones (daidzein, genistein, and glycitein), two metabolites of daidzein (equol and O-desmethylangolensin), three lignans (secoisolariciresinol, enterodiol, and enterolactone), and one flavanone (naringenin) in human urine and serum. A high throughput of samples has been achieved via the use of 96-well plate sample extraction and liquid chromatography/tandem mass spectrometry (LC-MS/MS) analysis incorporating column switching, thus making the assay suitable for use on large sample numbers, such as those found in epidemiological studies. The robustness of the assay was proven via the comparison of data generated on two different LC-MS/MS systems, with and without column switching.  相似文献   

12.
The 1,536-well microplate format has widely supplanted the 384-well microplate format for high-throughput screening and for IC(50) assays. Previously, liquid chromatography/mass spectrometry (LC/MS) analyses of such samples required manual transfers of the wells of interest from a 1,536-well plate into a 384-well plate. Because this manual transfer introduced a source of potential error, it became clear that a more appropriate solution would be to sample directly from the 1,536-well plates. Currently, commercially available 1,536-well plate auto samplers are not compatible with Waters LC/MS systems. The authors have modified their CTC PAL autosampler to support injection from up to twenty-four 1,536-well plates. This allows them to cherry-pick any sample from up to 36,864 wells on the autosampler. Because of its success at this Institute, sampling from 1,536-well plates has not only become the preferred method for LC/MS analysis from IC(50) plates but also become the standard format used for the handling of and the sampling from large combinatorial libraries.  相似文献   

13.
Bioanalytical methods using liquid/liquid extraction (LLE) and liquid chromatography with electrospray tandem mass spectrometry (LC-MS/MS) are widely used. The organic extracts need to be evaporated and reconstituted, hampering further improvement of throughput and automation. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well LLE by using hydrophilic interaction chromatography with MS/MS (HILIC-MS/MS) on silica column with high organic/low aqueous mobile phase. Omeprazole, its metabolite 5-OH omeprazole, and internal standard desoxyomeprazole, were extracted from 0.05 ml of human plasma using 0.5 ml of ethyl acetate in a 96-well plate. A portion (0.1 ml) of the ethyl acetate extract was diluted with 0.4 ml of acetonitrile and 10 microl was injected onto a Betasil silica column (50 mm x 3.0 mm, 5 microm) and detected by API 3000 and 4000 with (+) ESI. Mobile phase with linear gradient elution consists of acetonitrile, water, and formic acid (from 95:5:0.1 to 73.5:26.5:0.1 in 2 min). The flow rate was 1.5 ml/min with total run time of 2.75 min. The method was validated for a low limit of quantitation at 2.5 ng/ml for both analytes. The method was also validated for specificity, reproducibility, stability and recovery. Lack of adverse matrix effect and carry-over was also demonstrated. The inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels were <4.4% relative standard deviation (R.S.D.) and 4.1% relative error (R.E.) for omeprazole, and 4.5% R.S.D. and 5.6% R.E. for 5-OH omeprazole, respectively.  相似文献   

14.
A sensitive, stereoselective assay using solid phase extraction and LC-MS-MS was developed and validated for the analysis of (R)- and (S)-bupropion and its major metabolite (R,R)- and (S,S)-hydroxybupropion in human plasma and urine. Plasma or glucuronidase-hydrolyzed urine was acidified, then extracted using a Waters Oasis MCX solid phase 96-well plate. HPLC separation used an alpha(1)-acid glycoprotein column, a gradient mobile phase of methanol and aqueous ammonium formate, and analytes were detected by electrospray ionization and multiple reaction monitoring with an API 4000 Qtrap. The assay was linear in plasma from 0.5 to 200 ng/ml and 2.5 to 1000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. The assay was linear in urine from 5 to 2000 ng/ml and 25 to 10,000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. Intra- and inter-day accuracy was >98% and intra- and inter-day coefficients of variations were less than 10% for all analytes and concentrations. The assay was applied to a subject dosed with racemic bupropion. The predominant enantiomers in both urine and plasma were (R)-bupropion and (R,R)-hydroxybupropion. This is the first LC-MS/MS assay to analyze the enantiomers of both bupropion and hydroxybupropion in plasma and urine.  相似文献   

15.
To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.  相似文献   

16.
Propofol (2,6-diisopropyl phenol) is widely used for the induction and maintenance of anesthesia. Analyses of its pharmacokinetics require simple and sensitive methods for quantitation of propofol in human plasma. Previously reported HPLC and GC methods are limited by cumbersome extraction steps. We describe a novel method that combines sample preparation by solid-phase extraction (SPE) with hydrophilic-lipophilic balance cartridges and analysis with a sensitive LC-APCI-triple quadrupole mass spectrometry (MS/MS) method for better quantitation. The absolute recovery of the analyte was greater than 96%. The limit of quantification for propofol in plasma at a signal-to-noise ratio of 10 was 5 ng/ml. The precision of the assay yielded coefficients of variation ranging from 2.9 to 5.3% and an accuracies of 99-105%. Our method advances the quantitative analysis of propofol in human plasma by combining simple, rapid and efficient SPE with specific and sensitive quantitation by HPLC with APCI-MS/MS detection.  相似文献   

17.
Organophosphorus nerve agents (OPNA), chemically related to and derived from organophosphate insecticides, constitute a clear and present threat to both military and civilian targets. Military regimes and terrorist organizations have demonstrated the will and ability to produce mass casualties by dispersing organophosphorus nerve agents, which, in turn could terrorize populations and overwhelm healthcare systems. A high throughput, robust and sensitive analytical protocol has been developed for the quantitation of the urinary metabolites of sarin (GB), soman (GD), VX, Russian VX (RVX) and cyclohexylsarin (GF) utilizing solid phase extraction (SPE) followed by High Performance Liquid Chromatography (HPLC)-isotope dilution tandem mass spectrometry (LC/MS/MS). The method has demonstrated linearity and reproducibility (1-200 ng/mL) for all analytes and has a Limit of Quantitation (LOQ)< or =0.5 ng/mL for all analytes (S/N> or =10/1). The method was validated by performing 20 individual analyses over 10 days by five scientists with all values falling within two standard deviations of the mean.  相似文献   

18.
A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of muraglitazar, a PPAR alpha/gamma dual agonist, in human plasma. The internal standard, a chemical analogue, was dissolved in acetonitrile containing 0.1% formic acid. The solvent system was also served as a protein precipitation reagent. Human plasma samples (0.1 mL) and the internal standard solution (0.3 mL) were added to a 96-well plate. The plate was vortexed for 1 min and centrifuged for 5 min. Then the supernatant layers were directly injected into the LC/MS/MS system. The chromatographic separation was achieved isocratically on a Phenomenox C18(2) Luna column (2 mm x 50 mm, 5 microm). The mobile phase contained 20/80 (v/v) of water and acetonitrile containing 0.1% formic acid. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 3000. The standard curve, which ranged from 1 to 1000 ng/mL, was fitted to a 1/x weighted quadratic regression model. This single-pot approach effectively eliminated three time consuming sample preparation steps: sample transfer, dry-down, and reconstitution before the injection, while it preserved all the benefits of the traditional protein precipitation. By properly adjusting the autosampler needle offset level, only the supernatant was injected, without disturbing the precipitated proteins in the bottom. As a result, the quality of chromatography and column life were not compromised. After more than 600 injections, there was only slightly increase of column back-pressure. The validation results demonstrated that this method was rugged and provide satisfactory precision and accuracy. The method has been successfully applied to analyze human plasma samples in support of a first-in-man study. This method has also been validated in monkey and mouse plasma for the determination of muraglitazar.  相似文献   

19.
Introduction – Swainsonine, a polyhydroxy indolizidine alkaloid and known glycosidase inhibitor, is found in a number of different plants that cause a lysosomal storage disease known as locoism in the western USA. Most recently swainsonine has been analysed by LC‐MS/MS after sample extraction and preparation from ion‐exchange resins. Objective – To compare previously published sample preparation procedures with several new alternative procedures to provide methods using either commercially available solid‐phase extraction equipment or procedures which significantly reduce sample preparation time. Methodology – A previously reported and validated sample preparation method using ion‐exchange resin was compared with methods using a commercially available solid‐phase extraction cartridge, a solvent partitioning procedure or a single solvent extraction procedure using one of two solvents. Twenty different plant samples of varying swainsonine concentrations were prepared in triplicate and analysed by LC‐MS/MS. The measured concentration of swainsonine was then statistically compared between methods. Results – There were no statistically significant differences found between four of the five different sample preparation methods tested. Conclusion – A commercially available SPE cartridge can be used to replace the previously used ion‐exchange resin for swainsonine analysis. For very rapid analyses the SPE procedure can be eliminated and a simple, single solvent extraction step used for sample preparation. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

20.
Licea-Perez H  Wang S  Szapacs ME  Yang E 《Steroids》2008,73(6):601-610
A highly sensitive and selective quantitative method to accurately determine testosterone (Te) and 5alpha-dihydrotestosterone (DHT) in human serum is crucial to the success of Te replacement therapy for hypogonadism. To this end we have developed and validated a semi-automated and relatively high-throughput method in a 96-well plate format using ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC/MS/MS) for the simultaneous determination of Te and DHT in human serum. Te and DHT along with the internal standards [(2)H(3)]-Te and [(2)H(3)]-DHT were extracted from 300 microL of human serum by liquid-liquid extraction using methyl tertiary-butyl ether (MTBE), followed by derivatization with 2,3-pyridinedicarboxylic anhydride and solid-phase extraction for sample clean up. A novel chemical derivatization approach using 2,3-pyridinedicarboxylic anhydride was employed to achieve the MS sensitivity and selectivity required for DHT. Baseline separation of Te and DHT derivatives from endogenous steroid derivatives was achieved using UPLC technology on a C18 stationary-phase column with 1.7 microm particle size. The validity of using double charcoal-stripped female human serum as surrogate matrix for preparation of calibration standards was demonstrated through standard addition experiments. The method was validated over the concentration ranges of 0.2-40 ng/mL for Te and 0.01-2 ng/mL for DHT. The validation and study sample analysis results show that the method is rugged, precise, accurate, and well suited to support pharmacokinetic studies where approximately 300 samples can be extracted and analyzed in 1 day.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号