首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 17 毫秒
1.
In order to study the disposition of dimethylamphetamine (DMAP) and its metabolites, DMAP N-oxide, methamphetamine (MA) and amphetamine (AP), from plasma to hair in rats, a simultaneous determination method for these compounds in biological samples using gas chromatography–mass spectrometry with selected ion monitoring (GC–MS-SIM) was developed. As DMAP N-oxide partially degrades to DMAP and MA during GC–MS analysis, it was necessary to avoid conditions which co-extract the N-oxide in the sample preparation so as to assure no contribution of artifactual products from DMAP N-oxide in the detection of the other compounds. For confirmation of the satisfactory separation of DMAP N-oxide from the others, the internal standards used for quantification were labeled with different numbers of deuterium atoms. Determination of unchanged DMAP was performed without any derivatization, that of DMAP N-oxide was carried out after conversion into trifluoroacetyl-MA by reaction with trifluoroacetic anhydride, and MA and AP were quantified after trifluoroacetyl-derivatization.After intraperitoneal administration of DMAP HCl to pigmented hairy rats (5 mg kg−1 day−1, 10 days, n=3), concentrations of DMAP and its metabolites in urine, plasma and hair were measured by GC–MS-SIM. The area under the concentration versus time curves (AUCs) of DMAP, DMAP N-oxide, MA and AP in the plasma were 397.2±97.5, 279.7±68.3, 18.4±1.2 and 15.9±2.2 μg min ml−1, while their concentrations in the hair newly grown for 4 weeks after administration were 4.82±0.67. 0.45±0.09, 3.25±0.36 and 0.89±0.05 ng mg−1, respectively. This fact suggested that the incorporation tendency of DMAP N-oxide from plasma into hair was distinctly low in comparison with the other compounds.  相似文献   

2.
Two human urinary metabolites of the industrial solvent N,N-dimethylformamide (DMF), N-hydroxymethyl-N-methylformamide (HMMF) and N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC), were assayed using a new analytical method (gas chromatography and thermionic sensitive detection). Clean-up of urine samples includes a liquid–liquid extraction step followed by a solid-phase extraction step to separate HMMF and AMCC from other urine components. During clean-up, AMCC is converted into ethyl-N-methylcarbamate (EMC), and during gas chromatography, HMMF is degraded in the injector to N-methylformamide (NMF). All the validation data necessary for a quantitative procedure are given. The method was applied to urine samples from workers exposed to DMF and from the general population. The results were confirmed by mass spectrometric determination. For this purpose a further liquid–liquid extraction step was introduced in the clean-up procedure. Background levels of AMCC in the general population were identified.  相似文献   

3.
We report here the development and validation of an LC–MS method for quantitation of loperamide (LOP) and its N-demethyl metabolite (DMLOP) in human plasma. O-Acetyl-loperamide (A-LOP) was synthesized by us for use as an internal standard in the assay. After addition of the internal standard, the compounds of interest were extracted with methyl tert.-butylether and separated by HPLC on a C18 reversed-phase column using an acetonitrile–water gradient containing 20 mM ammonium acetate. The three compounds were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in plasma. Analytes were quantitated using positive electrospray ionization in a triple quadrupole mass spectrometer operating in the MS–MS mode. Selected reaction monitoring was used to quantify LOP (m/z 477→266), DMLOP (m/z 463→252) and A-LOP (m/z 519→266) on ions formed by loss of the 4-(p-chlorophenyl)-4-hydroxy-piperidyl group upon low energy collision-induced dissociation. Calibration curves, which were linear over the range 1.04 to 41.7 pmol/ml (LOP) and 1.55 to 41.9 pmol/ml (DMLOP), were run contemporaneously with each batch of samples, along with low (4.2 pmol/ml), medium (16.7 pmol/ml) and high (33.4 pmol/ml) quality control samples. The lower limit of quantitation (LLQ) of LOP and DMLOP was about 0.25 pmol/ml in plasma. The extraction efficiency of LOP and DMLOP from human plasma was 72.3±1.50% (range: 70.7–73.7%) and 79.4±12.8% (64.9–88.8%), respectively. The intra- and inter-assay variability of LOP and DMLOP ranged from 2.1 to 14.5% for the low, medium and high quality control samples. The method has been used successfully to study loperamide pharmacokinetics in adult humans.  相似文献   

4.
Reverse-phase liquid chromatography/electrospray ion trap mass spectrometry (LC-ESI-MSn) was established for identification of the molecular species of lactosylceramides. Lactosylceramides derived from porcine blood cells were separated on a CapcellPak C8 column using a mixture of methanol and 1 mM ammonium formate from the C16 to C26 fatty acyl chains based on the length of total carbon chains and the nature of sphingoid bases (w') and fatty acyl chains (Y0'-w') was identified by MS3 as their [M+H]+ ions. The same number of fatty acyl moieties appeared in the order of unsaturated, (2-)hydroxylated, and saturated components. The molecular species of lactosylceramides derived from porcine blood cells totaled more than 33 and included mainly C24:0-d18:1, Ch24:0-d18:1, Ch24:1-d18:1, C24:1-d18:1, and C22:0-d18:1 in addition to 28 minor species from C16:0 to C26:0 fatty acyl moieties. The molecular species of lactosylceramides in the membrane microdomain fraction of HL-60 cells (70% were differentiated into macrophage-lineage cells) were identified as C24:0-d18:1, C24:1-d18:1, C22:0-d18:1, C16:0-d18:1, and more than 21 other minor species. Our results suggest that reverse-phase LC-ESI-MSn is a useful and simple method for identification of lactosylceramide molecular species.  相似文献   

5.
A simple and rapid quantitative method for 13C-labelled urea ([13C]urea) in human serum was developed by using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS). This method is used to establish and normalize the [13C]urea breath test, which is considered as an effective diagnostic method for Helicobacter pylori infection. HPLC-APCI-MS, involving a simple pretreatment process such as diluting serum with water, was shown to be able to discriminate the extrinsic [13C]urea from intrinsic urea present at high concentration in serum. In addition, a 13C nuclear magnetic resonance spectroscopic quantitative method for [13C]urea in human urine is also described. The precision and accuracy of measured concentrations in these two methods were found to be within the acceptable limit. An application of these methods to investigate the pharmacokinetic profile of orally administered [13C]urea in human serum and urine is also presented.  相似文献   

6.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the determination of paclitaxel (Taxol) and its two major metabolites in human plasma has been developed. Samples were prepared after liquid-liquid extraction and analyzed on a C(18) column interfaced with a Q-Trap tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.05% formic acid) (65:35) at the flow rate of 0.25 mL/min. The analytes and internal standard docetaxel were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 0.5-500.0 ng/mL for paclitaxel, 6α-hydroxypaclitaxel and p-3'-hydroxypaclitaxel, respectively. The lower limit of quantification (LLOQ) was 0.5 ng/mL for paclitaxel, 6α-hydroxypaclitaxel and p-3'-hydroxypaclitaxel, respectively. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 8.18%. The accuracy determined at three concentrations was within ±10.8% in terms of relative error. The total run time was 7.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of paclitaxel and its metabolites in various biological fluids.  相似文献   

7.
A sensitive and specific high-performance liquid chromatographic method with fluorescence detection (excitation wavelength: 280 nm; emission wavelength: 360 nm) was developed and validated for the determination of vinorelbine in plasma and blood samples. The sample pretreatment procedure involved two liquid–liquid extraction steps. Vinblastine served as the internal standard. The system uses a Spherisorb cyano analytical column (250×4.6 mm I.D.) packed with 5 μm diameter particles as the stationary phase and a mobile phase of acetonitrile–80 mM ammonium acetate (50:50, v/v) adjusted to pH 2.5 with hydrochloric acid. The assay showed linearity from 1 to 100 ng/ml in plasma and from 2.5 to 100 ng/ml in blood. The limits of quantitation were 1 ng/ml and 2.5 ng/ml, respectively. Precision expressed as RSD was in the range 3.9 to 20% (limit of quantitation). Accuracy ranged from 92 to 120%. Extraction recoveries from plasma and blood averaged 101 and 75%, respectively. This method was used to follow the time course of the concentration of vinorelbine in human plasma and blood samples after a 10-min infusion period of 20 mg/m2 of this drug in patients with metastatic cancer.  相似文献   

8.
A column switching system for the determination of some polar pesticides and their main metabolites, such as aldicarb, aldicarb sulphoxide, aldicarb sulphone, carbofuran and 3-hydroxicarbofuran, in human urine has been developed. The limits of detection were between 0.3 and 1 μg/l. We used a simple solid-phase extraction with graphite carbon and a RPLC–LC analysis with UV detection yielding average recoveries between 84 and 110% (N=5) with RSD between 4 and 8%.  相似文献   

9.
A highly sensitive and specific quantification method of estrone and estradiol in human serum was described based upon the use of picolinoyl derivatization and liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) in a positive mode. Estrogens were treated with picolinoyl chloride hydrochloride or picolinic acid and 2-methyl-6-nitrobenzoic anhydride followed by a solid-phase extraction with ODS cartridge. Picolinoyl derivatization proceeded quantitatively even in a microscale, and the picolinoyl esters provided simple positive ESI-mass spectra showing [M+H](+) as base peaks for these estrogens. The picolinoyl derivatives of these estrogens showed 100-fold higher detection response compared to underivatized intact molecules by LC-ESI-MS (selected reaction monitoring). Using this derivatization, estrogens spiked in the charcoal treated human serum samples were analyzed with limit of quantification (LOQ), intra-day accuracy and precision of 1.0pg/ml, 96.0% and 9.9% for estrone, and 0.5pg/ml, 84.4% and 12.8% for estradiol, respectively. Estrone and estradiol added to the crude serum samples were recovered with comparable LOQ and accuracy obtained for the charcoal treated serum samples as well.  相似文献   

10.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

11.
A method was developed for the separation and quantification of the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate), its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate) and TCP (3,5,6-trichloro-2-pyridinol), the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide), its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), and its metabolites m-toluamide and m-toluic acid in rat plasma and urine. The method is based on using solid-phase extraction and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 210 and 280 nm. The compounds were separated using a gradient of 1–85% acetonitrile in water (pH 3.20) at a flow-rate ranging between 1 and 1.7 ml/min over a period of 15 min. The retention times ranged from 5.4 to 13.2 min. The limits of detection ranged between 20 and 150 ng/ml, while the limits of quantitation were between 150 and 200 ng/ml. Average percentage recovery of five spiked plasma samples was 80.2±7.9, 74.9±8.5, 81.7±6.9, 73.1±7.8, 74.3±8.3, 80.8±6.6, 81.6±7.3 and 81.4±6.5, and from urine 79.4±6.9, 77.8±8.4, 83.3±6.6, 72.8±9.0, 76.3±7.7, 83.4±7.9, 81.6±7.9 and 81.8±6.8 for chlorpyrifos, chlorpyrifos-oxon, TCP, pyridostigmine bromide, N-methyl-3-hydroxypyridinium bromide, DEET, m-toluamide and m-toluic acid, respectively. The relationship between peak areas and concentration was linear over a range between 200 and 2000 ng/ml.  相似文献   

12.
In this report, we introduce a liquid chromatography single-mass spectrometry method for metabolome quantification, using the LTQ Orbitrap high-resolution mass spectrometer. Analytes were separated with hydrophilic interaction liquid chromatography. At a working resolution of 30,000 (at m/z 400), the limit of detection varied from 50 fmol to 5 pmol for 25 metabolites tested. In terms of metabolite concentration, the linearity was about 2 to 3 orders of magnitude for most compounds (R2 > 0.99). To determine the accuracy of the system in complex sample matrices, the isotope dilution method was evaluated from mixtures of pure compounds and uniformly 13C-labeled cell extracts. With the application of this method, quantification was possible within single runs even when the pool sizes of individual metabolites varied from 0.13 to 55.6 μM. As a case study, intracellular concentrations of central metabolites were determined for Methylobacterium extorquens AM1 during growth on two different carbon sources, methanol and succinate. Reproducible results from technical and biological repetitions were obtained that revealed significant variations of intracellular metabolite pool sizes, depending on the carbon source. The LTQ Obitrap offers new perspectives and strategies for metabolome quantification.  相似文献   

13.
We have developed a simple, high-throughput batch immunoextraction (IAE) micropurification procedure for extracting a wide range of naturally occurring cytokinins (bases, ribosides, O- and N-glucosides, and nucleotides) from plant tissues in solutions that are compatible with ultra-performance liquid chromatography (UPLC), thereby facilitating sensitive subsequent analysis. The UPLC system was coupled to a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray interface (ESI). Small (mg) amounts of tissues were purified by solid-phase extraction (SPE) followed by an immunoaffinity clean-up step and two fast chromatographic separations of most cytokinin metabolites (bases, ribosides, and 9-glucosides in the first, O-glucosides and nucleotides in the second). Using UPLC, the runs were up to 4-fold faster than in standard cytokinin analyses, and both retention times and injection volumes were less variable (RSDs, 0.15-0.3% and 1.0-5.5%, respectively). In multiple reaction monitoring (MRM) mode, the detection limit for most of the cytokinins analyzed was close to 1 fmol (5-25 fmol for O-glucosides and nucleotides) and the linear range spanned at least five orders of magnitude. The extraction and purification method was optimized using poplar (Populus × canadensis Moench, cv Robusta) leaf samples, and the analytical accuracy was further validated using IAE-purified 10-day-old Arabidopsis thaliana plants spiked with 1 and 10 pmol of cytokinin derivatives. This approach can be used for rapid, sensitive qualitative and/or quantitative analysis of more than 50 natural cytokinins in minute amounts of plant tissues with high performance, robustness, and accuracy.  相似文献   

14.
To compare the trimethylamine N-oxygenase activity of liver microsomes from house musk shrew (Suncus murinus) and rat, a sensitive method for the quantitation of trimethylamine (TMA) N-oxide was developed using gas chromatography with flame thermionic detection. The limit of quantification was 0.5 μM and the calibration curve was linear at least up to 5 μM in incubations containing liver microsomal preparations from Suncus. The intra-day RSD values ranged from 10.4 to 12.8 at 0.5 μM and from 3.5 to 6.7 at 5 μM. The inter-day RSD values were 11.6 and 6.5 at 0.5 and 5 μM, respectively. This method provides a sensitive assay for TMA N-oxygenase activity in liver microsomes. Using this method we found that Suncus was capable of N-oxidizing trimethylamine at a very slow rate.  相似文献   

15.
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves.  相似文献   

16.
To study the use of hair analysis in monitoring drug compliance and historical changes in pharmacokinetics we developed a method for the quantitative determination of the anti-epileptic drug carbamazepine (CBZ) and trans-10,11-dihydro-10,11-dihydroxy-carbamazepine (CBZ-diol) in hair from carbamazepine users. Digestion by 1 M NaOH was found to be the best method for isolating CBZ and CBZ-diol from hair, followed by solid-phase extraction and reversed-phase HPLC with UV detection. Recoveries from spiked hair samples were 76–86%. Within-day precision (C.V.; n=10) for CBZ and CBZ-diol in hair of a CBZ user containing 10.9 μg/g CBZ and 3.2 μg/g CBZ-diol were 1.7 and 5.0%, respectively. Sectional hair analysis of a patient on a constant dosage of CBZ demonstrates an exponential decrease in hair concentrations of CBZ and CBZ-diol with increasing distance from the root, probably caused by shampooing. No CBZ-10,11-epoxide (CBZ-epox) could be detected. However, one component in the chromatogram is probably CBZ-β-hydroxythioether, an adduct of CBZ-epox with cysteine, or acridinethioacetal, its rearrangement product. The concentration of this component does not decrease with increasing distance from the root.  相似文献   

17.
Erythrocytes may affect several physiological processes because they are scavengers, vehicles, and (as recently highlighted) a producer of nitric oxide (NO). NO bioavailability is linked to arginine, its metabolic products ornithine and citrulline, and methylarginines. Here we describe a liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of analytes involved in the Arg/NO metabolic pathway in erythrocytes. Calibration functions were linear, and the interday coefficients of variation were less than 10%. Limit of quantification values make this method suitable for low concentration samples. The method presented here allows easy sample preparation and provides a valuable tool for the evaluation of the Arg/NO metabolic pathway in erythrocytes.  相似文献   

18.
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of triazolam and its metabolites, alpha-hydroxytriazolam (alpha-OHTRZ) and 4-hydroxytriazolam (4-OHTRZ), was developed and validated. Triazolam-D4 was used as the internal standard (IS). This analysis was carried out on a Thermo((R)) C(18) column and the mobile phase was composed of acetonitrile:H(2)O:formic acid (35:65:0.2, v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) and quantification was performed by multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 343.1-->308.3, 359.0-->308.3, 359.0-->111.2 and 347.0-->312.0 for triazolam, alpha-OHTRZ, 4-OHTRZ and triazolam-D4, respectively. LLOQ of the analytical method was 0.05ng/mL for triazolam and 0.1ng/mL for alpha-OHTRZ and 4-OHTRZ. The within- and between-run precisions were less than 15.26% and accuracy was -8.08% to 13.33%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of triazolam in healthy Chinese volunteers.  相似文献   

19.
A quantitative assay method by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the simultaneous determination of azelnidipine and its two metabolites, M-1 (aromatized form) and M-2 (hydroxylated form), in human plasma was developed and validated. Plasma samples, each of 1.0mL, were extracted by a single step liquid-liquid extraction using a mixture of ethyl acetate and hexane (1:1, v/v), and analyzed by the LC/ESI-MS/MS method. Three analytes were separated by isocratic elution on a C(18) column, and ionized using a positive ion electrospray ionization source. The ion transitions were monitored in selected reaction monitoring (SRM) mode. The chromatographic run time was 11min per injection, with retention time of 3.6, 10.2 and 6.8min for azelnidipine, M-1 and M-2, respectively. The calibration curves for azelnidipine, M-1 and M-2 well fitted to equations by a weighted (1/X(2)) quadratic regression over the range of 0.5-40.0ng/mL (r(2)>0.9979). The intra- and inter-assay precisions (coefficient of variation: C.V.), calculated from quality control (QC) samples, were less than 8.7 and 8.4%, 3.8 and 4.7%, and 11.9 and 13.9%, respectively, for azelnidipine, M-1 and M-2. The accuracy was within +/-9% for azelnidipine, within +/-7% for M-1 and within +/-16% for M-2. The overall recoveries for azelnidipine, M-1 and M-2 were 68.8-78.6%, 54.3-62.9% and 80.4-89.7%, respectively. All analytes evaluated demonstrated acceptable short-term, long-term, auto-sampler and stock solution stabilities. Furthermore, the method developed was successfully applied to pharmacokinetic studies on azelnidipine, M-1 and M-2 after an oral dose of 16mg CALBLOCK tablets (2mgx8mg tablets) to healthy volunteers.  相似文献   

20.
A method is described for the quantitative determination of quinoxaline-2-carboxylic acid (QCA) and methyl-3-quinoxaline-2-carboxylic acid (MQCA), the metabolites that have been designated as the marker residues for the veterinary drugs, carbadox and olaquindox, respectively, in swine tissue. The method is suitable for use as a confirmatory method under EU National Surveillance Schemes. Porcine liver samples were subjected to protease digestion followed by liquid-liquid extraction. Further clean-up was performed by automated solid phase extraction (SPE) and was followed by a final liquid-liquid extraction step. Analysis was performed using a narrow bore column HPLC coupled to electrospray MS/MS, operated in positive ion mode. MS/MS product ions were monitored at m/z 102 and 75 amu for QCA, m/z 145 and 102 amu for MQCA and at m/z 106 and 152 amu for the d(4)-QCA and d(7)-MQCA internal standards, respectively. The method has been validated at 3.0, 10, 50 and 150 microg kg(-1) for both metabolites. The method performance characteristics-the decision limit (CCalpha) and the detection capability (CCbeta) have been determined for QCA at 0.4 and 1.2 microg kg(-1), respectively, and for MQCA at 0.7 and 3.6 microg kg(-1), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号