The stress distribution within the components and the micromotion of the interface significantly influence the long-term function of the taper lock joint in a modular segmental bone replacement prosthesis. Bending-induced gap opening between the cone and the sleeve can lead to an inflow of biological fluids, and thus accelerate implant corrosion. Local areas of high stress can also accelerate the corrosive processes and initiate local yielding, which may lead to a fracture in one of the components. In this study, a 3-D finite element (FE) model of a modular segmental bone replacement prosthesis was developed to study the interface micromotion and component stress distribution under the maximum loads applied during gait for a taper lock joint with multiple material combinations. Bending was the main cause of the local high stresses and interface separation within the taper joint. For Ti6A14V components, cortical bone bridging and ingrowth across the taper lock gap reduced the peak stress by 45% and reduced the contact interface separation by 55%. Such tissue formation around the taper lock joint could also form a closed capsule to restrict the migration of potential wear particles and thus prevent the biologic process of bone resorption induced by metal debris.  相似文献   

2.
Failure of total knee arthroplasty is relatively often caused by problems of the patellofemoral replacement. The purpose of this study was to analyze the distribution of stresses within an anatomical patella and the changes in stress distribution after patellar resurfacing with a Miller-Galante I patellar implant using two- and three dimensional finite element models (FEM). To assess validity, FEM results were compared with morphological findings from contact radiographs and densitographs. Internal orientation of bone trabeculae is in good agreement with the orientation of theoretically calculated principal stresses. Almost unchanged principal tensile stresses after implantation, together with the lack of extreme stress peaks within the cancellous bone ensure stress compatibility of the implant. In the case of a firmly seated implant with good bone ingrowth, increased von Mises stresses are found near the fixation peg/plate junction. Their relevance for improved bone ingrowth near this part of the interface is emphasized. At the same time, material failure at the peg/plate junction can be better understood. An analysis of the early postoperative period assuming nonlinear interface conditions failed to demonstrate an uniform distribution of normal and tangential interface forces.  相似文献   

3.
After total hip replacement (THR) impingement of the implant components causes shear stresses at the acetabular implant-bone interface. In the current study the finite element method (FEM) was applied to analyse the shear stresses at a fully bonded implant-bone interface assuming total ingrowth of the cup. The FE model of a press-fit acetabular component and the proximal part of the femoral component incorporates non-linear material and large sliding contact. The model was loaded with a superior-medial joint load of 435 N simulating a two-legged stance. Starting at initial impingement, the femoral component was medially rotated by 20 degrees . The peak tilting shear stress of -2.6 MPa at the impingement site takes effect towards the pole of the cup. The torsional shear stress at the impingement site is zero. On each side of the impingement site, there are extrema of torsional shear stress reaching -1.8 and 1.8 MPa, respectively. The global peak shear stress during impingement may indicate a possible starting point for cup loosening. The pattern of the torsional shear stresses suggests that besides the symmetric lever-out, an additional asymmetrical tilting of the cup occurs that can be explained by the orientation of the applied joint load.  相似文献   

4.
Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 microns in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo.  相似文献   

5.
A two-dimensional, finite element study was undertaken to establish the stresses in the proximal tibia before and after total knee arthroplasty. Equivalent-thickness models in a sagittal plane were created for the natural, proximal tibia and for the proximal tibia with two different types of tibial plateau components. All components simulated bony ingrowth fixation, i.e. no cement layer existed between component and bone. In addition, the interface between component and bone was assumed to be intimately connected, representing complete bony ingrowth and a rigid state of fixation. Two load cases were considered: a joint reaction force acting in conjunction with a patellar ligament force, simulating the knee at 40 degrees of flexion; and a joint reaction force directed along the long axis of the tibia. For the natural tibia model, the pattern of principal stresses for loadcase 1 more closely corresponds to the epiphyseal plate geometry and trabecular morphology than do the principal stress patterns for loadcase 2. Judging from the distribution of principal stresses, loadcase 1 represents a more severe test of implant design than does loadcase 2. The model of the component with a peg predicted that the trabecular bone near the tip of the peg will experience higher than normal stresses, while the bone stresses near the posterior aspect adjacent to the metal tray will be reduced. A component without pegs that incorporates a posterior chamfer and an anterior lip lead to stress distributions closer to those existing in the natural tibia. The interface geometry for this design is based upon the contour of the epiphyseal plate.  相似文献   

6.
Two-dimensional, finite element studies were conducted of the proximal tibia before and after joint arthroplasty. Equivalent-thickness models projected onto the mid-frontal plane were created for the natural, proximal tibia and for the proximal tibia with four different types of tibial plateau components. All components simulated bony ingrowth fixation, i.e. no cement layer existed between component and bone. In addition, the interface between component and bone was assumed to be intimately connected, representing complete bony ingrowth and a rigid state of fixation. Loads consisted of bi-condylar and uni-condylar forces. Results indicated that conventional plateau designs with central posts or multiple pegs led to higher stress magnitudes in the trabecular bone near the distal ends of the post/pegs and stress shielding at more proximal locations. A design without posts or pegs whose interface geometry mimics the epiphyseal plate minimizes bone stress shielding. An implant consisting of separate components covering each condyle was found effective in limiting component tilting and the consequent tensile stresses caused by non-symmetrical, uni-condylar loading.  相似文献   

7.
The calcaneus is a desirable site for harvesting autologous bone for use in foot surgery. However, fracture of the calcaneus is a serious complication associated with bone harvesting from this site. Currently it is unknown how much bone may be safely harvested from the calcaneus without inducing a fracture. The purpose of this study was to investigate the effect of progressive bone removal from the calcaneus onto the mechanical stress redistribution of the foot, and therefore on the increase in fracture risk. Different loads were applied on the talus to evaluate the calcaneus stress distribution at different situations. Because of the potential increase in mechanical stress in the calcaneus, secondary to contraction of the Achilles tendon, we also evaluated the mechanical behavior properties of the foot with increasing traction force in the Achilles tendon. A three-dimensional (3D) finite element (FE) model developed from CT images obtained from a healthy individual was used to compute displacement, tension and compression stresses in six situations, including intact foot, and five depth of the bone block removed, with a maximum depth of 7.5 mm. The results from these simulations indicated that when the maximum load was applied at the Achilles tendon, the tension stress increased from 42.16 MPa in the intact foot to 86.28 MPa with maximum bone harvesting. Furthermore, as the volume of bone extracted from the calcaneus increases, there is a redistribution of stresses that differs significantly from the intact foot. In fact, although the maximum stress was not significantly affected by increasing the volume of bone harvested-except when increasing the Achilles tendon force-, stresses did increase in areas of the calcaneus is vulnerable to injury, leading to an increase in fracture risk.  相似文献   

8.
Finite element analysis is a useful analytical tool for the design of biomedical implants. The aim of this study was to investigate the behavior of temporomandibular joint implants with multiple design variables of the screws used for fixation of the implant. A commercially available implant with full mandible was analyzed using a finite element software package. The effects of different design variables such as orientation, diameter and stem length of the screws on the stress distribution in bone for two different surgical procedures were investigated. Considering the microstrain in bone as a principal factor, the acceptable ranges for screw diameter and length were determined. Parallel orientation of the screws performed better from a stress point of view when compared to the zig-zag orientation. Sufficient contact between the implant collar and mandibular condyle was shown to reduce the peak stresses which may lead to long term success. The distance between screw holes in the parallel orientation was much closer when compared to the zig-zag orientation. However, the stresses in bone near the screw hole area for the parallel orientation were within acceptable limits.  相似文献   

9.
High-energy synchrotron X-ray diffraction was used to study internal stresses in bone under in situ compressive loading. A transverse cross-section of a 12-14 year old beagle fibula was studied with 80.7 keV radiation, and the transmission geometry was used to quantify internal strains and corresponding stresses in the mineral phase, carbonated hydroxyapatite. The diffraction patterns agreed with tabulated patterns, and the distribution of diffracted intensity around 00.2/00.4 and 22.2 diffraction rings was consistent with the imperfect 00.1 fiber texture expected along the axis of a long bone. Residual compressive stress along the bone's longitudinal axis was observed in the specimen prior to testing: for 22.2 this stress equaled -95 MPa and for 00.2/00.4 was between -160 and -240 MPa. Diffraction patterns were collected for applied compressive stresses up to -110 MPa, and, up to about -100 MPa, internal stresses rose proportionally with applied stress but at a higher rate, corresponding to stress concentration in the mineral of 2.8 times the stress applied. The widths of the 00.2 and 00.4 diffraction peaks indicated that crystallite size perpendicular to the 00.1 planes increased from t=41 nm before stress was applied to t=44 nm at -118 MPa applied stress and that rms strain epsilon(rms) rose from 2200 muepsilon before loading to 4600 muepsilon at the maximum applied stress. Small angle X-ray scattering of the unloaded sample, recorded after deformation was complete, showed a collagen D-period of 66.4 nm (along the bone axis).  相似文献   

10.
To assess the potential of a porous hydroxyapatite matrix to serve as a bone graft substitute, bilateral 15 X 20 mm craniectomy defects were reconstructed in 17 dogs with blocks of implant and split-rib autografts. Specimens were retrieved at 3, 6, 12, 24, and 48 months, and undecalcified sections were prepared for microscopy and histometry. The implant and graft cross-sectional areas did not change with time, documenting their equivalent ability to maintain cranial contour. Bone ingrowth extended across the implant from one cranial shelf to the other in 15 specimens. Little apparent bone ingrowth was seen in most graft specimens. Two implants and three grafts were nonunited, possibly due to lack of fixation or the orientation of the histology sections. The implant specimens were composed of 39.3 percent hydroxyapatite matrix, 17.2 percent bone ingrowth, and 43.5 percent soft-tissue ingrowth. The graft specimens were composed of 43.7 percent bone and 56.3 percent soft tissue. This study supported the thesis that a porous hydroxyapatite matrix may function in part as a bone graft substitute. The brittle hydroxyapatite matrix undoubtedly became stronger with bone ingrowth, but the degree of cranial protection achieved was not measured in this study. The size of the cranial defect used in this study did not permit estimation of the distance over which bone ingrowth may be reliably expected. There remains a need for greater understanding of the causes of nonunion, the extent of predictable ingrowth depth, and the strength of the resultant implant-bone composite.  相似文献   

11.
Assuming that high stress peaks in the bone can trigger bone resorption a screw-shaped bone implant should be given such a design that the peak stresses arising in the bone, as a result of a certain load, are minimized. Using idealized assumptions the aim of the study was to analyse the effect of variations of the size and the profile of the thread of an axially loaded, screw-shaped, bone implant upon the magnitude of the stress peaks in cortical bone. The investigation was performed by means of axisymmetric finite element analysis. It was found that the shape of the thread profile has a profound effect upon the magnitude of the stresses in the bone and that very small threads of a favourable profile can be quite effective.  相似文献   

12.
Finite element stress analyses were conducted of the canine femoral head before and after implantation of various surface replacement-type components. The femoral head was replaced by four implant geometries; (a) shell, (b) shell with peg, (c) shell with rod, and (d) a new epiphyseal replacement design. All implants were modelled to simulate bony ingrowth along the underside of the shell and along the surfaces of the peg and rod. The results indicated that in the normal femur the forces are transferred from the articular surface through the femoral head cancellous bone to the inferior cortical shell of the femoral neck. After shell-type surface replacement, forces were transferred more distally at the rim of the shell and at the end of the peg or rod, thereby reducing the stresses in the proximal head cancellous bone. Computer simulation of bone remodelling due to proximal bone stress reduction was shown to accentuate the abnormality of the stress fields. Surface replacement with a lower modulus material created a less abnormal redistribution of bone stresses. The new epiphyseal replacement design resulted in stress distributions similar to those in the normal femoral head and minimal shear stresses at the implant/bone interface. These findings suggest that the epiphyseal replacement concept may provide better initial mechanical integrity and create a more benign milieu for adaptive bone remodelling than conventional, shell-type surface replacement components.  相似文献   

13.
A variety of bone chambers are used in orthopedic research to study bone and tissue ingrowth in small and large animals. If different bone chambers are placed in one species, differences in bone ingrowth are observed. For instance, bone ingrowth in the bone conduction chamber (BCC) is high, but is low or absent in the repeated sampling bone chamber (RSBC). This difference may be explained by the design and fixation of these chambers. It is known that stress shielding and micromovement can influence bone formation. The objective of the study reported here was to determine whether stress shielding or soft tissue movement affected bone ingrowth in the BCC in the goat. Two types of caps were made, with fixation similar to that of the fixation plate of the RSBC. By placing the caps over the BCCs and fixating the caps directly to the tibial bone, the effect of stress shielding was studied. One cap was in direct contact with the bone chamber underneath, the other cap did not touch the chamber. This difference was used to observe whether movement of the soft tissue on top of the chamber and cap would affect bone ingrowth. Each limb received one control chamber without a cap and a chamber with a cap, either with or without contacting the BCC, yielding four implants per goat. After 12 weeks, bone and total tissue ingrowths were measured. Bone ingrowth was seen in 38 of 40 chambers. Total tissue and bone ingrowths were comparable between control chambers and BCCs with a cap, irrespective of type. Neither stress shielding, nor lack of movement of soft tissue affected bone ingrowth. Other factors in the design of the chambers were responsible for the difference in bone ingrowth between the BCC and the RSBC.  相似文献   

14.
The objective of this investigation was to examine the stress-morphology relationships for trabecular bone around implants with different surface characteristics. Stainless steel spheres with either a polished surface or a sintered-bead porous coating were implanted unilaterally into equine patellae and maintained for a 6 month period. Stereological methods were used to quantify the trabecular bone morphology and finite element analyses were performed to predict the trabecular bone stresses. In general, the remodeling response around the smooth implants was greater than that around those porous implants that exhibited bone ingrowth. In accordance with these differences, the finite element models predicted greater changes in the stresses adjacent to the smooth implants due to the nonlinear boundary conditions. However, it did not appear that the trajectorial theory, in its simplest form, was applicable to the remodeling induced by the implants. A linear relationship between the change in bone areal density and the change in von Mises effective stress provides support for the hypothesis that the architecture of trabecular bone corresponds to an optimal structure. The results also demonstrated that, under certain circumstances, small changes in the stress state may result in large changes in the principal material orientation.  相似文献   

15.
Optimized experimental conditions for extracting accurate information at subpixel length scales from analyzer-based X-ray imaging were obtained and applied to investigate bone regeneration by means of synthetic β-TCP grafting materials in a rat calvaria model. The results showed a 30% growth in the particulate size due to bone ongrowth/ingrowth within the critical size defect over a 1-month healing period.  相似文献   

16.
We measured the lengths and diameters of four long bones from 118 terrestrial carnivoran species using museum specimens. Though intrafamilial regressions scaled linearly, nearly all intraordinal regressions scaled non-linearly. The observed non-linear scaling of bone dimensions within this order results from a systematic decrease in intrafamilial allometric slope with increasing body size. A change in limb posture (more upright in larger species) to maintain similar peak bone stresses may allow the nearly isometric scaling of skeletal dimensions observed in smaller sized mammals (below about 100 kg). However, strong positive allometry is consistently observed in a number of large terrestrial mammals (the largest Carnivora, the large Bovidae, and the Ceratomorpha). This suggests that the capacity to compensate for size increases through alteration of limb posture is limited in extremely large-sized mammals, such that radical changes in bone shape are required to maintain similar levels of peak bone stress.  相似文献   

17.
This study aims to investigate the influence of the presence, shape and depth of NCCLs on the mechanical response of a maxillary second premolar subjected to functional and non-functional occlusal loadings using 3-D finite element (FE) analysis. A three-dimensional model of a maxillary second premolar and its supporting bone was constructed based on the contours of their cross-sections. From the sound model, cervical defects having either V- or U-shapes, as found clinically, were subtracted in three different depths. The models were loaded with 105 N to simulate normal chewing forces according to a functional occlusal loading (F1) vertically applied and two non-functional loadings (F2 and F3) obliquely oriented. Two alveolar bone crest heights were tested. Ansys™ FE software was used to compute stress distributions and maximum principal stress for each of the models. The presence of a lesion had no effect on the overall stress distribution of the system, but affected local stress concentrations. Non-functional loadings exhibited tensile stresses concentrating at the cervical areas and root surfaces, while the functional loading resulted in homogeneous stress distributions within the tooth. V-shaped lesions showed higher stress levels concentrated at the zenith of the lesion, whereas in U-shaped defect stresses concentrated over a wider area. As the lesions advanced in depth, the stress was amplified at their deepest part. A trend of stress amplification was observed with decreasing bone height. These results suggest a non-linear lesion progression with time, with the progression rate increasing with patient's age (deeper lesions and lower bone support).  相似文献   

18.
In this paper the variation of normal and shear stresses along a path defined on the bone–dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibular incisor and the surrounding bone. The bone and the implant are assumed to be perfectly bonded. The finite element method with 2D plane strain assumption is used to compute interfacial stresses. Highest continuous interfacial stresses are encountered in the region where the implant collar engages the cortical region, and near the apex of the implant in the subcortical region. Stress concentrations in the interfacial stresses occur near the geometric discontinuities on the implant contour, and jumps in stress values occur where the elastic modulus of the bone transitions between the cortical and trabecular bone values. Among the six contour parameters, the slope and the length of the implant collar, and the implant diameter influence the interfacial stress levels the most, and the effects of changing these parameters are significantly noticed only in the cortical bone (alveolar ridge) area. External threads cause significant stress concentrations in interfacial stresses in otherwise smoothly varying regions. This work shows that the presence of external threads could cause significant variations in both normal and shear stresses along the bone–implant interface, but not reduction in shear stress as previously thought.  相似文献   

19.
Captorhinids are a speciose clade of sauropsids that are crucial to understand several aspects of basal amniote general biology. Members of the Captorhinidae explored different diets and, amongst basal amniotes, were one of the first groups to demonstrate high‐fibre herbivory. Several papers have been published on the cranial anatomy of captorhinids, but there are relatively few studies which focus on the post‐cranium, especially on the appendicular skeleton and long bones. This contribution presents the first quantitative long bone scaling in Captorhinidae performed through morphometric analyses. From classical biomechanical research, it is well‐established that to accommodate an increase in size, gravity will result in elastic deformation of long bones. This outcome is especially significant in terrestrial tetrapods with a sprawling limb posture such as captorhinids, where great torsional stresses are applied to long bones, both during locomotion and in the resting phase. In this paper, we test whether the consistent evolutionary size increase in captorhinids led to major re‐patterning in long bone structure as theoretically expected, based on the theory of elastic similarity. Morphometric analysis shows that, apart from a small positive allometry in the humerus, captorhinid long bones scale geometrically as body size increases. Thus, the predicted elastic similarity to maintain similar levels in peak stress with an increase in dimensions does not seem not to apply to long bone evolution in captorhinids. We propose that, as already observed experimentally in larger‐bodied varanid lizards, large captorhinids could also mitigate size‐related increases in stress by reducing femur rotation and increasing the percentage of the stride cycle during which the right hindfoot was on the ground (i.e. the duty factor). In this way, large captorhinids could avoid reaching peak stress thresholds by sacrificing speed during locomotion and without a substantial long bone re‐patterning or postural change.  相似文献   

20.
Cementless hip prostheses with porous outer coating are commonly used to repair the proximally damaged femurs. It has been demonstrated that stability of prosthesis is also highly dependent on the bone ingrowth into the porous texture. Bone ingrowth is influenced by the mechanical environment produced in the callus. In this study, bone ingrowth into the porous structure was predicted by using a mechano-regulatory model. Homogenously distributed pores (200 and 800 \(\upmu \)m in diameter) and functionally graded pores along the length of the prosthesis were introduced as a porous coating. Bone ingrowth was simulated using 25 and 12 \(\upmu \)m micromovements. Load control simulations were carried out instead of traditionally used displacement control. Spatial and temporal distributions of tissues were predicted in all cases. Functionally graded pore decreasing models gave the most homogenous bone distribution, the highest bone ingrowth (98%) with highest average Young’s modulus of all tissue phenotypes approximately 4.1 GPa. Besides this, the volume of the initial callus increased to 8.33% in functionally graded pores as compared to the 200 \(\upmu \)m pore size models which increased the bone volume. These findings indicate that functionally graded porous surface promote bone ingrowth efficiently which can be considered to design of surface texture of hip prosthesis.  相似文献   