首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Song JF  He P  Guo W 《Analytical biochemistry》2002,304(2):212-219
The polarographic catalytic wave of vitamin P in the presence of persulfate was studied by linear potential scan polarography and cyclic voltammetry. Vitamin P yielded a single reduction wave in acidic aqueous solution, which was ascribed to a 2e(-), 2H(+) reduction of the carbonyl group in the C-4 position. Actually, the carbonyl group C=O first underwent a 1e(-), 1H(+) reduction to form a neutral free radical, and the further 1e(-), 1H(+) reduction of the free radical was simultaneous with its following chemical reactions. When S(2)O(2-)(8) was present, the free radical of vitamin P was oxidized by both S(2)O(2-)(8) and its reduction intermediate, the sulfate radical anion SO(*-)(4), to regenerate the original, which resulted in the production of a polarographic catalytic wave of vitamin P. Based on this catalytic wave, a novel method for the determination of vitamin P was proposed. In 0.02 M tartaric acid-sodium tartrate (pH 3.3) buffer containing 5.0 x 10(-3) M K(2)S(2)O(8), the peak potential of the catalytic wave was -1.42 V (vs SCE) and the peak current was rectilinear to the vitamin P concentration in the range of 8.0 x 10(-9)-1.0 x 10(-6) M (r = 0.9994, n = 13). The catalytic wave of 2.0 x 10(-7) M vitamin P enhanced the polarographic current 70 times compared with the corresponding reduction wave. The detection limit was 2.0 x 10(-9) M, and the relative standard deviation at the 2.0 x 10(-7) M level was 0.7% (n = 15). The proposed method was used for the determination of vitamin P content in the pharmaceutical preparation of tablets and the medicinal plant Sophora japonica L. without previous separation.  相似文献   

2.
We discovered that 4-(2-pyridylazo) resorcinol (PAR) has a strong catalytic effect on luminol-potassium ferricyanide chemiluminescence (CL). Results indicated that the chemiluminescence intensities at maximum light emission were linearly corrected with the concentration of PAR over the range 1.0 x 10(-5)-1.0 x 10(-7) mol/L. A detection limit of 5.7 x 10(-8) mol/L for PAR was achieved. It was found that some metal ions strongly affected this catalytic reaction. Based on this finding, the luminol-potassium ferricyanide-PAR reaction was developed for the determination of metal ions. The detection limits (S/N = 3) for Ni2+, Cr3+, Zn2+, Co2+ and Mn2+ were determined to be 1.0 x 10(-9) mol/L, 5.0 x 10(-9) mol/L, 5.0 x 10(-8) mol/L, 1.0 x 10(-9) mol/L and 1.0 x 10(-8) mol/L, respectively. In addition, the relative standard deviation values for these metal ion assays were in the range 0.82-2.72% (n = 6).  相似文献   

3.
On the top of a multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (MWNTs/GCE), Pt nanoclusters were electrochemically deposited, fabricating a Pt/MWNTs composite modified electrode, Pt/MWNTs/GCE. X-ray photoelectron spectroscopy, powder X-ray diffraction and field emission scanning electron microscope were used for the surface characterization of the electrode, and demonstrated the formation and distribution of Pt clusters of Pt nanoparticles of 8.4 nm in averaged size in the MWNTs matrix. The preliminary study found that this composite modified electrode has strong electrocatalytic activity toward the oxidation of estrogens involving estradiol, estrone and estriol. The voltammetric behavior of estrogens on this electrode was investigated by cyclic voltammetry, linear sweep voltammetry and square-wave voltammetry. In comparison with the MWNTs/GCE or a Pt nanoparticles modified GCE prepared in the similar way, this composite modified electrode exhibited much higher current sensitivity and catalytic activity. This electrode is also stable. The linear range of square-wave voltammetric determination was 5.0 x 10(-7)-1.5 x 10(-5)mol/L for estradiol, 2.0 x 10(-6)-5.0 x 10(-5)mol/L for estrone, and 1.0 x 10(-6)-7.5 x 10(-5)mol/L for estriol. Under an assumption that the concentration ratio of estradiol:estrone:estriol is 2:2:1, the real sample of blood serums was tested for the determination using this electrode. Satisfactory result was obtained with averaged recovery of 105%.  相似文献   

4.
The reaction of soluble manganese (IV) with sulphite in acidic condition was found to elicit weak chemiluminescence (CL). The CL signal was remarkably enhanced in the presence of three fluoroquinolones, viz. norfloxacin, ofloxacin and ciprofloxacin. Based on these observations, a new flow-injection CL method was developed for the determination of these fluoroquinolones. The method allows determination in the range 5.0 x 10(-8)-1.0 x 10(-6) mol/L for norfloxacin, 1.0 x 10(-7)-8.0 x 10(-6) mol/L for ofloxacin and 1.0 x 10(-7)-3.0 x 10(-5) mol/L for ciprofloxacin, with detection limits of 3 x 10(-8) mol/L, 5 x 10(-8) mol/L and 3 x 10(-8) mol/L, respectively. The method was applied to the determination of fluoroquinolones in pharmaceutical preparations.  相似文献   

5.
A novel method for the determination of fluorene and acenaphthene on solid phase extraction-room-temperature phosphorescence (SPE-RTP) was studied. beta-cyclodextrin (beta-CD) was chemically bonded onto chromatography paper by reaction with epichorohydrin in an ultrasonic bath. The RTP signal of fluorene and acenaphthene included on the beta-CD-modified paper was increased more than 10 times compared with non-modified filter paper, indicating the formation of the inclusion complex. The conditions for the of RTP of compounds were studied in detail. The linear ranges of fluorene and acenaphthene concentrations to the RTP intensity were over two orders of magnitude (8.0 x 10(-7)-4.0 x 10(-5) mol/L for fluorene) with a correlation coefficient of 0.999. The concentration limits of detection for fluorene and acenaphthene were 1.11 x 10(-8) mol/L and 3.8 x 10(-7) mo/L, respectively. When the sampling volume was 10 microL, the absolute LODs for fluorene and acenaphthene were 18.4 pg/spot and 0.58 ng/spot, respectively. The modified filter paper was used for solid phase extraction (SPE) and the retention behaviour of fluorene and acenaphthene was examined. The enrichment efficiency of the analytes was higher than 100-fold. The SPE-RTP coupling technique was applied directly to the determination of fluorene and acenaphthnene in environmental water samples.  相似文献   

6.
Voltammetric behavior of 4',7-dimethoxy-3'-isoflavone sulfonic sodium (DISS) was studied by linear sweep voltammetry and cyclic voltammetry. DISS caused two waves between pH 8.0 and 12.0. Above pH 8.0, the peak current of first wave Pc1 of DISS was enhanced in the presence of cetyltrimethylammonium bromide (CTAB). Based on this, a novel method for the determination of DISS was proposed. In Britton-Robinson buffer solution (pH 11.7) containing 9.4 x 10(-6)mol L(-1) CTAB, the peak potential of first wave Pc1 of DISS was -1.59 V (vs standard saturated calomel electrode) and its first-order derivative peak current was proportional to the concentration of DISS in the range 5.0 x 10(-8)-6.0 x 10(-7)mol L(-1) (r=0.998). The detection limit was 1 x 10(-8)mol L(-1), which was 10 times lower than that of the corresponding reduction wave. The method was applied to the determination of DISS in synthetic samples.  相似文献   

7.
An ECL approach was developed for the determination of codeine or morphine based on tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)(2+)) immobilized in organically modified silicates (ORMOSILs). Tetramethoxysilane (TMOS) and dimethyldimethoxysilane (DiMe-DiMOS) were selected as co-precursors for ORMOSILs, which were then immobilized on a surface of glassy carbon electrode (GCE) by a dip-coating process. Ru(bpy)(3)(2+) was immobilized in the ORMOSIL film via ion-association with poly(p-styrenesulphonate). The ORMOSIL-modified GCE presented good electrochemical and photochemical activities. In a flow system, the eluted codeine or morphine was oxidized on the modified GCE and reacted with immobilized Ru(bpy)(3)(2+) at a potential of +1.20 V (vs. Ag/AgCl). The modified electrode was used for the ECL determination of codeine or morphine and showed high sensitivity. The calibration curves were linear in the range 2 x 10(-8)-5 x 10(-5) mol/L for codeine and 1 x 10(-7)-3 x 10(-4) mol/L for morphine. The detection limit was 5 x 10(-9) mol/L for codeine and 3 x 10(-8) mol/L for morphine, at signal:noise ratio (S:N)=3. Both codeine and morphine showed reproducibility with RSD values <2.5% at 1.0 x 10(-6) mol/L. Furthermore, the modified electrode immobilized Ru(bpy)(3)(2+) was applied to the ECL determination of codeine or morphine in incitant samples.  相似文献   

8.
Gao D  Hu J  Yang M  Li Q 《Analytical biochemistry》2006,358(1):70-75
A novel COOH+ ion implantation-modified indium tin oxide (COOH/ITO) electrode was prepared for the first time and applied for determination of daunomycin (or daunorubicin [DNR]). The electrode showed higher catalytic activity than bare ITO electrode with good reproducibility and stability. The determination condition of linear voltammetry was optimized. A calibration curve was obtained over the range 2.0 x 10(-7) to 5.0 x 10(-6)mol/L, with a correlation coefficient of 0.9909 and a limit of detection of 1.0 x 10(-7)mol/L. The selectivity of the electrode was illustrated by determination of DNR in samples prepared of urine. X-ray photoelectron spectroscopy (XPS) analysis results showed that the implanted COOH+ maintained characteristics of organic group -COOH. A field emission-scanning electron microscope (FSEM) result showed that the implanted surface caused defects and partial dislocations and formed many active centers.  相似文献   

9.
Human serum albumin (HSA) or anti-human serum albumin (anti-HSA) yields a catalytic hydrogen wave at about -1.85V (vs Ag/AgCl) in 0.25M NH(3).H(2)O-NH(4)Cl (pH 8.58) buffer. When 1.0 x 10(-2)M K(2)S(2)O(8) is present, the catalytic hydrogen wave is further catalyzed, producing a parallel catalytic wave of hydrogen as catalyst in nature, termed the parallel catalytic hydrogen wave. The sensitivity of the parallel catalytic hydrogen wave is higher by two orders of magnitude than that of the catalytic hydrogen wave. Using the parallel catalytic hydrogen wave of anti-HSA or HSA in the presence of K(2)S(2)O(8), two sensitive methods for the determination of anti-HSA were developed. One is a direct determination based on the parallel catalytic hydrogen wave of anti-HAS itself, and the other is a homogeneous immunoassay based on measuring the decrease of the peak current of the parallel catalytic hydrogen wave of HSA after homogeneous immunoreaction of HSA with anti-HSA. In the direct determination, the second-order derivative peak current of the parallel catalytic hydrogen wave of anti-HSA itself is rectilinear to its titer in the range from 1:1.0 x 10(7) to 1:8.4 x 10(6). In the homogeneous immunoassay, the decrease in the second-order derivative peak current of the parallel catalytic hydrogen wave of HSA is linearly related to the added anti-HSA in the titer range from 1:3.0 x 10(7) to 1:6.0 x 10(6). These assays are highly sensitive and rapid in operation and can be used to evaluate such antigens and their antibodies as those that could yield the parallel catalytic hydrogen wave.  相似文献   

10.
In this article, a composite paste electrode consisted of multiwall carbon nanotube (MWCNT) and room temperature ionic liquids (RTILs) was developed for fabrication of electrochemiluminescence (ECL) sensor. The electrochemical and ECL behaviors of this sensor were investigated in detail. This ECL sensor exhibited extraordinary stability during long-term potential cycling. It was found that the light emission of this ECL sensor could be enhanced by methamphetamine hydrochloride (MA.HCl) dramatically. Based on which, a new method based on this ECL sensor has been developed for determination of MA.HCl. The method exhibited a good reproducibility, wide-range linearity, high sensitivity and stability with a detection limit (signal-to-noise ratio=3) of 8.0 x 10(-9)mol/L, and the relative standard deviation was 3.1% for 1 x 10(-5)mol/L MA.HCl (n=10).  相似文献   

11.
人或牛血清白蛋白溶液调至pH10并在4℃左右放置30h,诱导出重复性良好的极谱峰。然后把试样溶液调至适当pH并记录极谱电流。在浓度低于1.0×10-5mol/L时,峰电流对浓度作图是直线,试样浓度可从图上直接读出。对影响白蛋白测定的诸因素作了详细研究和讨论。结果对富含硫的蛋白质的极谱研究有参考价值。  相似文献   

12.
A novel CL method for the determination of tannic acid (TA) was established based on TA inhibition of the chemiluminescence (CL) emission of the luminol-hydrogen peroxide CL system catalysed by tetrasulphonated manganese phthalocyanine (MnTSPc) under alkaline conditions. The peak height is proportional to the natural logarithm of concentration of TA in the range 1.0 x 10(-7)-3.0 x 10(-10) mol/L with a detection limit of 5.6 x 10(-11) mol/L and the relative standard deviation was 2.5% for the determination of 1.0 x 10(-8) mol/L TA (n = 11). The proposed method has been successfully applied to the determination of TA in Chinese gall and industrial wastewater.  相似文献   

13.
A synthesis of beta-cyclodextrin (beta-CD) dimer, containing two beta-CD moieties that are linked through their sides by ethylenediamine, was presented. The dimer was characterized by means of IR, (1)H NMR, (13)C NMR, and elemental analysis. The inclusion complexation behavior of beta-cyclodextrin dimer with tranilast was studied in an aqueous KH(2)PO(4)-citric acid buffer solution of pH 2.00 at room temperature by spectrofluorimetry. Based on the significant enhancement of fluorescence intensity of tranilast, a spectrofluorimetric method with high sensitivity and selectivity was developed for the determination of tranilast in bulk aqueous solution in the presence of ethylenediamine beta-CD dimer. The apparent association constant of the complex was 8.39 x 10(3) L mol(-1), and the linear range was 10.8-1.40 x 10(4) ng mL(-1) with the detection limit 3.2 ng mL(-1). There was no interference from the excipients normally used in tablets and serum constituents. The proposed method was successfully applied to the determination of tranilast in serum.  相似文献   

14.
A sensitive and specific luminescence method for the determination of ibuprofen (IB) in pharmaceutical formulations in aqueous solution is described. The method is based on the luminescence sensitization of terbium (Tb(3+)) by formation of ternary complex with IB in the presence of tri-n-octylphosphine oxide (TOPO) and Tween-20 as surfactant. The luminescence signal for Tb-IB-TOPO is monitored at lambda(ex) = 229 nm and lambda(em) = 545 nm. Optimum conditions for the formation of the complex in aqueous system, were 16 mmol/L TRIS buffer, pH 5.7, TOPO 200 micromol/L and 15 micromol/L of Tb(3+), which allows for the determination of 9.7 x 10(-7) - 9.7 x 10(-6) mol/L IB with a detection limit of 1.2 x 10(-7) mol/L. The relative standard deviations of the method were <1.4%, indicating excellent reproducibility. The proposed method was successfully applied for the assays of IB in pharmaceutical formulations with average recoveries of 100.3-102.5%.  相似文献   

15.
A simple electrogenerated chemiluminescence (ECL) analysis method for the determination of norfloxacin (NFLX) is reported. It is based on ECL produced by Na(2)SO(3), which is sensitized by the Tb-NFLX complex. The relative ECL intensity of the Tb(3+)-NFLX-Na(2)SO(3) system is proportional to the amount of NFLX. The optimized experimental conditions were investigated. The linear range and detection limit for NFLX were 1.0 x 10(-10)-8.0 x 10(-7) mol/L and 2.8 x 10(-11) mol/L, respectively. This method was successfully applied to the determination of NFLX in a capsule. NFLX in urine can be directly detected without pretreatment or separation.  相似文献   

16.
A new spectrofluorimetric method was developed for the determination of trace amounts of 5-hydroxytryptamine (5-HT). Using chlorosulphonylthenoyltrifluoroacetone (CTTA)-europium (Eu(3+)) ion as a fluorescent probe in a buffer solution at pH 11.0, 5-HT can remarkably enhance the fluorescence intensity of the CTTA-Eu(3+) complex at lambda = 612 nm; the enhanced fluorescence intensity of Eu(3+) is proportional to the concentration of 5-HT. Optimum conditions for the determination of 5-HT were also investigated. The linear range and detection limit for the determination of 5-HT were 1.0 x 10(-7)-1.2 x 10(-5) mol/L and 8.5 x 10(-8) mol/L, respectively. This method is simple, practical and relatively free of interference from coexisting substances, and can be applied to assess 5-HT in urine samples.  相似文献   

17.
Lanthanum hydroxide nanowires modified carbon paste electrode (LNW/CPE) exhibiting an electrocatalytic response toward the oxidation of mefenamic acid (MFA) is described. The catalytic action of the LNW/CPE on the oxidation of MFA via one-electron and one-proton transfer is attributed to the formation of the porous construction and the increase of efficient surface of the electrode due to the adulteration of LNW with carbon powders. Using the LNW/CPE, a linear sweep voltammetric method for the determination of MFA and other drugs with diphenylamine parent is proposed. A linear range of 2.0 x 10(-11) to 4.0 x 10(-9)mol L(-1) is obtained along with a detection limit of 6.0 x 10(-12)mol L(-1).  相似文献   

18.
Glucose-6-phosphate dehydrogenase (G6PD) catalyses the first step of the pentose phosphate pathway which generates NADPH for anabolic pathways and protection systems in liver. G6PD was purified from dog liver with a specific activity of 130 U x mg(-1) and a yield of 18%. PAGE showed two bands on protein staining; only the slower moving band had G6PD activity. The observation of one band on SDS/PAGE with M(r) of 52.5 kDa suggested the faster moving band on native protein staining was the monomeric form of the enzyme.Dog liver G6PD had a pH optimum of 7.8. The activation energy, activation enthalpy, and Q10, for the enzymatic reaction were calculated to be 8.96, 8.34 kcal x mol(-1), and 1.62, respectively.The enzyme obeyed "Rapid Equilibrium Random Bi Bi" kinetic model with Km values of 122 +/- 18 microM for glucose-6-phosphate (G6P) and 10 +/- 1 microM for NADP. G6P and 2-deoxyglucose-6-phosphate were used with catalytic efficiencies (kcat/Km) of 1.86 x 10(6) and 5.55 x 10(6) M(-1) x s(-1), respectively. The intrinsic Km value for 2-deoxyglucose-6-phosphate was 24 +/- 4mM. Deamino-NADP (d-NADP) could replace NADP as coenzyme. With G6P as cosubstrate, Km d-ANADP was 23 +/- 3mM; Km for G6P remained the same as with NADP as coenzyme (122 +/- 18 microM). The catalytic efficiencies of NADP and d-ANADP (G6P as substrate) were 2.28 x 10(7) and 6.76 x 10(6) M(-1) x s(-1), respectively. Dog liver G6PD was inhibited competitively by NADPH (K(i)=12.0 +/- 7.0 microM). Low K(i) indicates tight enzyme:NADPH binding and the importance of NADPH in the regulation of the pentose phosphate pathway.  相似文献   

19.
A novel hydrogen peroxide biosensor was fabricated for the determination of H(2)O(2). The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H(2)O(2) in the linear range from 2.6 x 10(-6) mol/L to 8.8 x 10(-3) mol/L with a detection limit of 6.4 x 10(-7) mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.  相似文献   

20.
A new fluorescent reagent, 1,5-bis(4,6-dichloro-1,3,5-triazinylamino)naphthalene, containing two active chlorines, was synthesized by a one-step reaction. Under the optimum conditions for the determination of dopamine, the enhanced fluorescence intensity is proportional to the dopamine concentration. The fluorescence intensity was measured at lambda(ex/em) = 400/460 nm, with and without dopamine. The linear range and detection limit for the determination of dopamine were 1.0 x 10(-7) mol/L-5.0 x 10(-5) mol/L and 4.0 x 10(-8) mol/L. This method is simple, practical, can afford good precision and accuracy and can be successfully applied to assess dopamine in injections and human serum samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号