首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
3-Nitrotyrosine (NO(2)Tyr) is a potential biomarker of reactive-nitrogen species (RNS) including peroxynitrite. 3-Nitrotyrosine occurs in human plasma in its free and protein-associated forms and is excreted in the urine. Measurement of 3-nitrotyrosine in human plasma is invasive and associated with numerous methodological problems. Recently, we have described an accurate method based on gas chromatography (GC)-tandem mass spectrometry (MS) for circulating 3-nitrotyrosine. The present article describes the extension of this method to urinary 3-nitrotyrosine. The method involves separation of urinary 3-nitrotyrosine from nitrite, nitrate and l-tyrosine by HPLC, preparation of the n-propyl-pentafluoropropionyltrimethylsilyl ether derivatives of endogenous 3-nitrotyrosine and the internal standard 3-nitro-l-[(2)H(3)]tyrosine, and GC-tandem MS quantification in the selected-reaction monitoring mode under negative-ion chemical ionization conditions. In urine of ten apparently healthy volunteers (years of age, 36.5+/-7.2) 3-nitrotyrosine levels were determined to be 8.4+/-10.4 nM (range, 1.6-33.2 nM) or 0.46+/-0.49 nmol/mmol creatinine (range, 0.05-1.30 nmol/mmol creatinine). The present GC-tandem MS method provides accurate values of 3-nitrotyrosine in human urine at the basal state. After oral intake of 3-nitro-l-tyrosine by a healthy volunteer (27.6 microg/kg body weight) 3-nitro-l-tyrosine appeared rapidly in the urine and was excreted following a biphasic pharmacokinetic profile. Approximately one third of administered 3-nitro-l-tyrosine was excreted within the first 8 h. The suitability of the non-invasive measurement of urinary 3-nitrotyrosine as a method of assessment of oxidative stress in humans remains to be established.  相似文献   

2.
Measurement of 3-nitro-L-tyrosine (NO(2)Tyr) and protein-related 3-nitro-L-tyrosine in human plasma is associated with numerous methodological problems which result in highly divergent basal plasma levels often ranging within two orders of magnitude. Recently, we have described an interference-free GC-tandem MS-based method for NO(2)Tyr which yielded the lowest basal plasma NO(2)Tyr levels reported thus far. This method was extended to quantify protein-associated 3-nitrotyrosine and in particular 3-nitrotyrosinated albumin (NO(2)TyrALB) in human plasma. NO(2)TyrALB and albumin (ALB) were extracted from plasma by affinity column extraction and digested enzymatically at neutral pH. 3-Nitro- L-[2H(3)]tyrosine was used as internal standard. In plasma of 18 healthy young volunteers the molar ratio of NO(2)TyrALB to albumin-derived tyrosine (TyrALB), i.e. NO(2)TyrALB/TyrALB, was determined to be 1.55+/-0.54x1:10(6) (mean+/-SD). The plasma concentration of NO(2)TyrALB was estimated as 24+/-4 nM. The NO(2)Tyr plasma levels in these volunteers were determined to be 0.73+/-0.53 nM. In the same volunteers, NO(2)TyrALB/TyrALB, NO(2)TyrALB and NO(2)Tyr were measured 15 days later and the corresponding values were determined to be 1.25+/-0.58x1:10(6), 25+/-6 nM and 0.69+/-0.16 nM. For comparison, NO(2)Tyr and NO(2)TyrALB were measured in six plasma samples from healthy volunteers by GC-MS and GC-tandem MS. Different values were found for NO(2)Tyr, i.e. 5.4+/-2.8 versus 2.7+/-1.5 nM, and comparable values for NO(2)TyrALB/TyrALB, i.e. 0.5+/-0.2x1:10(6) versus 0.4+/-0.1x1:10(6), by these methods. The ratio of the values measured by GC-MS to those measured by GC-tandem MS were 2.9+/-3.1 for NO(2)Tyr and 1.2+/-0.2 for NO(2)TyrALB/TyrALB. The present GC-tandem MS method provides accurate values of NO(2)Tyr and NO(2)TyrALB in human plasma.  相似文献   

3.
L-Tyrosine and L-tyrosine residues in proteins are attacked by various reactive-nitrogen species (RNS) including peroxynitrite to form 3-nitrotyrosine (NO(2)Tyr) and protein-associated 3-nitrotyrosine (NO(2)TyrProt). Circulating NO(2)Tyr and NO(2)TyrProt have been suggested and are widely used as biomarkers of oxidative stress in humans. In this article the mass spectrometry (MS)-based analytical methods recently reported for the quantification of circulating levels of NO(2)Tyr and NO(2)TyrProt are discussed. These methodologies differ in sensitivity, selectivity, specificity and accessibility to interferences with the latter mainly arising from artifactual formation of NO(2)Tyr and NO(2)TyrProt during sample treatment such as acidification and chemical derivatization. Application of these methodologies to healthy normal humans revealed basal circulating levels for NO(2)Tyr which range between 0.7 and 64 nM, i.e. by two orders of magnitude. Application of gas chromatography-tandem mass spectrometry (GC-tandem MS) methods by two independent research groups by using two different protocols to avoid artifactual nitration of L-tyrosine revealed almost identical mean plasma levels of the order of 1.0 nM in healthy humans. The lower limits of quantitation (LOQ) of these methods were 0.125 and 0.3n M, respectively. This order of magnitude for basal NO(2)Tyr is supported by two liquid chromatography-tandem mass spectrometry (LC-tandem MS) methods with LOQ values of 4.4 and 1.4 nM. On the basis of the data provided by GC-tandem MS and LC-tandem MS the use of a range of 0.5-3 nM for NO(2)Tyr and of 0.6 pmol/mg plasma protein or a molar ratio of 3-nitrotyrosine to tyrosine in plasma proteins of the order of 1:10(6) for NO(2)TyrProt in plasma of healthy humans as reference values appear reasonably justified. Recently reported clinical studies involving 3-nitrotyrosine as a biomarker of oxidative stress are discussed in particular from the analytical point of view.  相似文献   

4.
Cytochrome P450 dependent epoxidation and non-enzymic lipid peroxidation of oleic acid (cis-9-octadecenoic acid) result in the formation of cis-9,10-epoxyoctadecanoic acid (cis-EODA). This oleic acid oxide has been identified indirectly in blood and urine of humans. Reliable concentrations of circulating cis-EODA have not been reported thus far. In the present article, we report on the first GC-tandem MS method for the accurate quantitative determination in human plasma of authentic cis-EODA as its pentafluorobenzyl (PFB) ester. cis-[9,10-2H2]-EODA (cis-d2-EODA) was synthesized by chemical epoxidation of commercially available cis-[9,10-2H2]-9-octadecenoic acid and used as an internal standard for quantification. Endogenous cis-EODA and externally added cis-[9,10-2H2]-EODA were isolated from acidified plasma samples (1 ml; pH 4.5) by solvent or solid-phase extraction, converted into their PFB esters, isolated by HPLC and quantified by selected reaction monitoring. The parent ions [M-PFB]- at mass-to-charge ratio (m/z) 297 for cis-EODA and m/z 299 for (cis-d2-EODA) were subjected to collisionally-activated dissociation and the corresponding characteristic product ions at m/z 171 and 172 were monitored. In plasma of nine healthy humans (5 females, 4 males), cis-EODA was found to be present at 47.6+/-7.4 nM (mean+/-S.D.). Plasma cis-EODA levels were statistically insignificantly different (P=0.10403, t-test) in females (51.1+/-3.4 nM) and males (43.1+/-2.2 nM). cis-EODA was identified as a considerable contamination in laboratory plastic ware and found to contribute to endogenous cis-EODA by approximately 2 nM. The present GC-tandem MS method should be useful in investigating the physiological role(s) of cis-EODA in humans.  相似文献   

5.
Benzene, an environmental pollutant, is myelotoxic and leukemogenic in humans. The molecular mechanisms that can account for its biological effects have not been fully elucidated. We hypothesize that one of the underlying mechanism involves nitration of proteins by peroxynitrite and/or by bone marrow myeloperoxidase-dependent pathways in nitric oxide (NO) metabolism. Using 3-nitrotyrosine [Tyr(NO(2))] as a biomarker for NO-induced damage to proteins, we examined the effects of benzene on the levels of Tyr(NO(2)) in bone marrow in vivo. Groups of 8 weeks old B6C3F(1) male mice were given a single i.p. injection of benzene (50, 100, 200 or 400mg/kg bodyweight) in corn oil. The mice in control groups received either no treatment or a single injection of the vehicle. The mice were killed 1h after treatment and proteins were isolated from bone marrow, lung, liver and plasma. The proteins were enzymatically hydrolyzed; amino acids were separated and purified by high pressure liquid chromatography, derivatized, and quantified by electron capture-negative chemical ionization-gas chromatography/mass spectrometry (EC-NCI-GC/MS). In the GC/MS assay, 3-nitro-l-[(13)C(9)]tyrosine was used as an internal standard and l-[(2)H(4)]tyrosine served to monitor artifactual formation of 3-nitrotyrosine during sample preparation and analysis. We found that treatment of mice with benzene elevates nitration of tyrosine residues in bone marrow proteins. There was a dose (50-200mg benzene/kg b.w.)-dependent increase in protein-bound Tyr(NO(2)) formation (1.5- to 4.5-fold); however, the levels of Tyr(NO(2)) at 400mg benzene/kg b.w. were significantly higher than control but lower than that formed at 200mg benzene/kg b.w. The results of this study, for the first time, indicate that benzene increases protein-bound 3-Tyr(NO(2)) in bone marrow in vivo, and support our previous finding that benzene is metabolized to nitrated products in bone marrow of mice; collectively, these results may in part account for benzene-induced myelotoxicity.  相似文献   

6.
We developed an isotope dilution HPLC-atmospheric pressure chemical ionization-tandem mass spectrometry (HPLC-APCI-MS/MS) method for the simultaneous determination of p-tyrosine, phenylalanine, o,o'-dityrosine, m-tyrosine, o-tyrosine, 3-chlorotyrosine and 3-nitrotyrosine and 8-hydroxy-2'-deoxyguanosine (8-OHdG) that requires no extensive sample pre-treatment. p-[(2)H(4)]Tyrosine and o,o'-[(2)H(6)]dityrosine were used as internal standards. Calibration curves of the method were linear (r(2)=0.990-0.999) over a concentration range of 0.03-10 microM for o-tyrosine; 0.04-10 microM for 3-nitrotyrosine and 3-chlorotyrosine; 0.05-10 microM for o,o'-dityrosine; and for m-tyrosine; 1.0-100 microM for p-tyrosine and for phenylalanine; and 0.01-10 microM for 8-OHdG. The detection limits were from 0.025 to 0.05 microM for the tyrosine derivatives; 0.01 microM for 8-OHdG; and 0.5 microM for p-tyrosine and for phenylalanine, respectively. Within-day coefficients of variation (CV) for spiked human urine samples ranged from 2.7 to 7.0%, except for 8-OHdG (13.7%). Between-day variations ranged from 7.9 to 13.0%, except for o-tyrosine (CV = 18.2%), and for 8-OHdG (CV = 24.7%).The background levels of p-tyrosine, phenylalanine, o,o'-dityrosine, and o-tyrosine in morning urine of eight healthy volunteers were 3890+/-590, 3420+/-730, 5.8+/-0.3, and 9.2+/-1.5 micromol/mol creatinine, respectively. Using the present HPLC-APCI-MS/MS method, the urinary background levels of m-tyrosine, 3-chlorotyrosine, 3-nitrotyrosine and 8-OHdG were below the limit of detection.  相似文献   

7.
Measurement of nitrotyrosine levels in biological fluids can serve as a biomarker for oxidative/nitrative damage arising from formation of reactive nitrogen species, including peroxynitrite. Peroxynitrite is formed by the reaction of the superoxide radical (O2.-) with the nitric oxide radical (.NO) that is generated by nitric oxide synthase (NOS). This article describes an immunoaffinity liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to measure 3-nitrotyrosine at very low (picomolar) levels. Incorporation of a pronase digestion step prior to the immunoaffinity LC-MS/MS allowed for measuring not only free amino acid but also protein 3-nitrotyrosine in biological fluids. The use of an in-line antibody column allowed for increased specificity as compared with previously reported assays. The assay is linear over a range of 5 to 500 pg/ml (0.022-2.20 nM, r(2)=0.9987), with the lower detection limit being 5 pg/ml. In addition to its increased sensitivity and specificity, this assay showed great nitrotyrosine recovery from biological fluids when either nitrotyrosine or nitrotyrosine-containing peptides were added exogenously. The utility of this assay for nitrotyrosine as a clinically translatable biomarker was demonstrated by quantifying both free and total nitrotyrosine levels in various biological fluids, including urine, plasma, serum, cerebrospinal fluid (CSF), and synovial fluid (SF) from both preclinical species and human subjects. Thus, whether in an animal model of human disease or in a clinical setting, the quantification of nitrotyrosine levels should provide support for NOS-driven pathology and its blockade following therapeutic intervention.  相似文献   

8.
A highly sensitive and simple isocratic high-performance liquid chromatography method was developed for determination of 3-nitrotyrosine in human plasma with precolumn derivatization with 4-fluoro-7-nitrobenzo-2-oxa-1,3-diazole. The precision of the method was satisfactory (coefficient of variation 4.8%), and the detection limit was established at 0.1 pmol of 3-nitrotyrosine allowing the determination at the level of 6 pmol/ml in human plasma. The recoveries of 3-nitrotyrosine and α-methyltyrosine, an internal standard, were 89.3 +-7.1 and 85.7±7.6%, respectively. The 3-nitrotyrosine level was 31±6 pmol/ml (mean±S.D., n=9) in plasma from healthy volunteers. Since 3-nitrotyrosine is a stable product of peroxynitrite, an oxidant formed by a reaction of nitric oxide and superoxide radicals, the measurement of its plasma concentration may be useful as a marker of nitric oxide-dependent oxidative damage.  相似文献   

9.
Nitric oxide (NO), the endogenous modulator of vascular tone and structure, originates from oxidation of L-arginine catalysed by NO synthase (NOS). The L-arginine derivative L-homoarginine serves as an alternative NOS substrate releasing NO, competing with L-arginine for NOS, arginase, and arginine transport. In the present article we report a liquid chromatography-tandem mass spectrometric (LC-tandem MS) method for the determination of L-homoarginine in human plasma by stable-isotope dilution. L-[(13)C(6)]-Homoarginine was used as internal standard. This method provides high sample throughput of 25-μl aliquots of plasma with an analysis time of 4 min using LC-tandem MS electrospray ionisation in the positive mode (ESI+). Specific transitions for L-homoarginine and L-[(13)C(6)]-homoarginine were m/z 245 → m/z 211 and m/z 251 → m/z 217, respectively. The mean intra- and interassay CVs were 7.4 ± 4.5% (±SD) for 0.1-50 μmol/L and 7.5 ± 2.0% for 2 and 5 μmol/L, respectively. Applying this method, a mean plasma concentration of L-homoarginine of 2.5 ± 1.0 μmol/L was determined in 136 healthy humans.  相似文献   

10.
Halogenation and nitration of biomolecules have been proposed as key mechanisms of host defense against bacteria, fungi, and viruses. Reactive oxidants also have the potential to damage host tissue, and they have been implicated in disease. In the current studies, we describe specific, sensitive, and quantitative methods for detecting three stable markers of oxidative damage: 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine. Our results indicate that electron capture-negative chemical ionization-gas chromatography/mass spectrometry (EC-NCI GC/MS) is 100-fold more sensitive than liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS) for analyzing authentic 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine. Using an isotopomer of tyrosine to evaluate artifactual production of the analytes during sample preparation and analysis, we found that artifact generation was negligible with either technique. However, LC-MS/MS proved cumbersome for analyzing multiple samples because it required 1.5 h of run and equilibration time per analysis. In contrast, EC-NCI GC/MS required only 5 min of run time per analysis. Using EC-NCI GC/MS, we were able to detect and quantify attomole levels of free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in human plasma. Our results indicate that EC-NCI GC/MS is a sensitive and specific method for quantifying free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in biological fluids in a single, rapid analysis and that it avoids generating any of the analytes ex vivo.  相似文献   

11.
A novel, sensitive, and specific method is presented for the quantification of endogenous 3-nitrotyrosine in rat plasma based on isotope dilution liquid chromatography-electrospray ionization tandem mass spectrometry, using 3-nitro-2,5,6-d(3)-l-tyrosine as an internal standard. The extraction and cleanup method entails three major steps: protein precipitation, solid-phase extraction with an aminopropyl cartridge, followed by derivatization of 3-nitrotyrosine to the corresponding butyl ester. The analysis of the stable butyl ester derivative circumvented matrix interferences, which were encountered on the analysis of the nonderivatized analyte in plasma, and thus significantly improved sensitivity. The mass spectral acquisition of 3-nitrotyrosine butyl ester was done in the positive ion mode using selected reaction monitoring of two specific transitions. The response was linear over the concentration range 1.4-28.5 nM, and the recoveries of spiked 3-nitrotyrosine in rat plasma exceeded 75%. The detection and quantification limits of 3-nitrotyrosine in rat plasma (165 microL equivalent injected) approached 0.43 and 1.4 nM (0.07 and 0.23 pmol, on column), respectively. This study also addresses the potential artifactual formation of 3-nitrotyrosine, which may lead to an overestimation of the background levels of the biomarker. Solid-phase extraction of 3-nitrotyrosine was required prior to esterification to avoid artifactual nitration of tyrosine. In this context, analysis of eight rat plasma samples showed quantifiable levels in only four of the samples of the order of 1.4-1.5 nM.  相似文献   

12.
Asymmetric dimethylarginine (ADMA; N(G),N(G)-dimethyl-L-arginine) is the most important endogenous inhibitor of nitric oxide synthase and a potential risk factor for cardiovascular diseases. This article describes a gas chromatographic-tandem mass spectrometric (GC-tandem MS) method for the accurate quantification of ADMA in human plasma or serum and urine using de novo synthesized [2H(3)]-methyl ester ADMA (d(3)Me-ADMA) as the internal standard. Aliquots (100 microl) of plasma/serum ultrafiltrate or native urine and of aqueous solutions of synthetic ADMA (1 microM for plasma and serum; 20 microM for urine) are evaporated to dryness. The residue from plasma/serum ultrafiltrate or urine is treated with a 100 microl aliquot of 2M HCl in methanol, whereas the residue of the ADMA solution is treated with a 100 microl aliquot of 2M HCl in tetradeuterated methanol. Methyl esters are prepared by heating for 60 min at 80 degrees C. After cooling to room temperature, the plasma or urine sample is combined with the d(3)Me-ADMA sample, the mixture is evaporated to dryness, the residue treated with a solution of pentafluoropropionic (PFP) anhydride in ethyl acetate (1:4, v/v) and the sample is incubated for 30 min at 65 degrees C. Solvent and reagents are evaporated under a stream of nitrogen gas, the residue is treated with a 200 microl aliquot of 0.4M borate buffer, pH 8.5, and toluene (0.2 ml for plasma, 1 ml for urine). Reaction products are extracted by vortexing for 1 min, the toluene phase is decanted, and a 1 microl aliquot is injected into the GC-tandem MS instrument. Quantitation is performed by selected reaction monitoring (SRM) of the common product ion at m/z 378 which is produced by collision-induced dissociation of the ions at m/z 634 for endogenous ADMA and m/z 637 for d(3)Me-ADMA. In plasma and urine of healthy humans ADMA was measured at concentrations of 0.39+/-0.06 microM (n=12) and 3.4+/-1.1 micromol/mmol creatinine (n=9), respectively. The limits of detection and quantitation of the method are approximately 10 amol and 320 pM of d(3)Me-ADMA, respectively.  相似文献   

13.
We established a method for the detection of free and total (free and bound) malondialdehyde (MDA) in human plasma samples after derivatisation with 2,4-dinitrophenylhydrazine (DNPH). Free MDA was prepared by perchloric acid deproteinisation whereas an alkaline hydrolysation step for 30 min at 60°C was introduced prior to protein precipitation for the determination of total MDA. Derivatisation was accomplished in 10 min at room temperature subsequently chromatographed by HPLC on a reversed-phase 3 μm C18 column with UV detection (310 nm). The detection limit was 25 pmol/ml for free and 0.3 nmol/ml for total MDA. The recovery of MDA added to different human plasma samples was 93.6% (n=11; RSD 7.1%) for the hydrolysation procedure. In samples from 12 healthy volunteers who underwent a hypoxic treatment (13% O2 for 6 h) we estimated a baseline value of total MDA of 2.16 nmol/ml (SD 0.29) (ambient air) with a significant increase to 2.92 (nmol/ml, SD 0.57; P=0.01) after the end of this physiological oxidative stress challenge. Plasma values of free MDA in these samples were close to our detection limit. The presented technique can easily performed with an isocratic HPLC apparatus and provides highly specific results for MDA as do sophisticated GC–MS methods.  相似文献   

14.
An analytical method is described for the quantification of S-nitrosoglutathione (GSNO), a potent physiological vasodilator and inhibitor of platelet aggregation, in the presence of a high excess of reduced glutathione (GSH). The method is based on the quantitative elimination of GSH by N-ethylmaleimide, the conversion of GSNO by 2-mercaptoethanol to GSH, its reaction with o-phthalaldehyde (OPA) to form a highly fluorescent and UV-absorbing tricyclic isoindole derivative, and subsequent high-performance liquid chromatographic (HPLC) separation with fluorescence and/or UV absorbance detection. The OPA derivatives of GSH and GSNO obtained by this method were found to be identical by mass spectrometry. GSH (up to 50 microM) did not interfere with the analysis of GSNO (up to 1000 nM). The limits of detection of the method for buffered aqueous solutions of GSNO were determined as 3 nM using fluorescence and 70 nM using UV absorbance detection. Isolation of GSNO by HPLC analysis (pH 7.0) of plasma ultrafiltrate samples (200 microl) prior to derivatization allows specific and artifact-free quantification of GSNO in human and rat plasma. Reduced and oxidized glutathione, nitrite, and cysteine did not interfere with the measurement of GSNO in human and rat plasma. The limit of quantitation (LOQ) of the combined method was determined as 100 nM of GSNO in human plasma ultrafiltrate using fluorescence detection. No endogenous GSNO could be detected in ultrafiltrate samples of plasma of 10 healthy humans at concentrations exceeding the LOQ of the method. After iv infusion of GSNO (125 micromol/kg body wt) in a rat for 20 min GSNO and GSH were detected in rat plasma at 60 and 130 microM, respectively. The method should be useful to investigate formation, metabolism, and reactions of GSNO in vitro and in vivo at physiologically relevant concentrations.  相似文献   

15.
Aminoethylcysteine ketimine decarboxylated dimer (AECK-DD; systematic name: 1,2-3,4-5,6-7,8-octahydro-1,8a-diaza-4,6-dithiafluoren-9(8aH)-one) is a previously described metabolite of cysteamine that has been reported to be present in mammalian brain, urine, plasma, and cells in culture and vegetables and to possess potent antioxidative properties. Here, we describe a stable isotope gas chromatography-tandem mass spectrometry (GC-MS/MS) method for specific and sensitive determination of AECK-DD in biological samples. (13)C(2)-labeled AECK-DD was synthesized and used as the internal standard. Derivatization was carried out by N-pentafluorobenzylation with pentafluorobenzyl bromide in acetonitrile. Quantification was performed by selected reaction monitoring of the mass transitions m/z 328 to 268 for AECK-DD and m/z 330 to 270 for [(13)C(2)]AECK-DD in the electron capture negative ion chemical ionization mode. The procedure was systematically validated for human plasma and urine samples. AECK-DD was not detectable in human plasma above approximately 4nM but was present in urine samples of healthy humans at a maximal concentration of 46nM. AECK-DD was detectable in rat brain at very low levels of approximately 8pmol/g wet weight. Higher levels of AECK-DD were detected in mouse brain (~1nmol/g wet weight). Among nine dietary vegetables evaluated, only shallots were found to contain trace amounts of AECK-DD (~6.8pmol/g fresh tissue).  相似文献   

16.
3-Nitrotyrosine (3-NT) is formed by the reaction of peroxynitrite with either free or protein-bound tyrosine residues and has been proposed as a biomarker of oxidative stress caused by reactive nitrogen species. This study describes the development of an HPLC electrochemical detection assay for free 3-NT capable of measuring this metabolite at the very low (nanomolar) levels encountered physiologically. We employed a dual-cell coulometric approach in which 3-NT is first reduced at an upstream cell to 3-aminotyrosine, which itself is then oxidized at the downstream cell. The method was shown to be linear over the range of 1-500 nM (r = 0.999), with a detection limit (signal/noise ratio of 3) of 0.5 nM (25 fmol on column). Ten consecutive injections of 2 and 20 nM 3-NT standards produced coefficients of variation of 5.88 and 1.87%, respectively. Validation of the identity of the 3-NT peak was confirmed by coelution with authentic standards and by the in vitro production of 3-NT by incubation of 3-morpholinylsydnoneimine (SIN-1, 100 microM), a molecule releasing nitric oxide and superoxide in solution at a pH of 7.0 or higher with tyrosine (10 microM). Using this method, 3-NT was detected in human liver microdialysate (levels up to 2.6 nM), although levels in rat spinal cord dialysate were below the limit of detection.  相似文献   

17.
Because reactive nitrogen species (RNS) have potent inflammatory activity, they may be involved in the inflammatory process in pulmonary diseases. We recently reported increased numbers of 3-nitrotyrosine immunopositive cells, which are evidences of RNS production, in the sputum of patients with chronic obstructive pulmonary disease (COPD) and patients with asthma compared with healthy subjects. In the present study, we attempted to quantify this protein nitration in the airways by means of high-performance liquid chromatography (HPLC) used together with an electrochemical detection system that we developed. Sputum samples were obtained from 15 stable COPD patients, 9 asthmatic patients and 7 healthy subjects by using hypertonic saline inhalation. The values for the molar ratio of protein-bound 3-nitrotyrosine/tyrosine in patients with asthma (4.31 +/- 1.13 x 10(-6), p < 0.05) and patients with COPD (3.04 +/- 0.36 x 10(-6), p < 0.01) were significantly higher than those in healthy subjects (1.37 +/- 0.19 x 10(-6)). The levels of protein-bound 3-nitrotyrosine in the airways were not significantly different in asthmatic patients and COPD patients. A significant negative correlation was found between values for protein-bound 3-nitrotyrosine/tyrosine and % FEV1 values in patients with COPD (r = -0.53, p < 0.05) but not in patients with asthma. These results suggest that our HPLC-electrochemical method is useful for quantifying RNS production in human airways. More importantly, they show that increased RNS production in the airways seems to contribute in a critical way to the pathogenesis of COPD, and that the effects of RNS in airways may differ in asthma and COPD.  相似文献   

18.
A sensitive and specific isotope dilution liquid chromatography-electrospray tandem mass spectrometry method was developed for the determination of the 3-nitrotyrosine residue levels in rat plasma proteins. The assay is based on the cleavage of proteins with concentrated hydrochloric acid to release both 3-nitrotyrosine and tyrosine. To control the potential artifactual nitration of tyrosine residues during the proteolysis, samples are spiked with (13)C(9)-labeled tyrosine and the level of (13)C(9)-labeled 3-nitrotyrosine is measured. The clean-up process entails hydrolysate fortification with 2,5,6-d(3)-3-nitrotyrosine, followed by solid-phase extraction on octadecylsilyl (to isolate tyrosine) and aminopropylsilyl (to isolate 3-nitrotyrosine) cartridges. Tyrosine and 3-nitrotyrosine fractions are mixed in an appropriate ratio prior to the analysis. The method was applied to animals exposed to ferric nitrilotriacetate to induce oxidative stress.  相似文献   

19.
A high-performance liquid chromatographic method for the determination of free reduced cysteine and N-acetylcysteine in human plasma at the basal state and after oral administration of N-acetylcysteine is described. The method is based on acid-catalysed conversion of plasma thiols to the corresponding S-nitroso derivatives by excess of nitrite and their subsequent cation-pairing RP-HPLC with detection at 333 nm. Recovery rates of cysteine and N-acetylcysteine added to human plasma were 94.6 and 99.6%, respectively. Inter- and intra-day precision were below 6%. In healthy humans (n=5), free reduced cysteine was determined to be (mean±S.E.) 10.0±0.96 μM. No N-acetylcysteine was detected in plasma of these subjects above the limit of detection (e.g. 170 nM). The method was successfully applied to a pharmacokinetic study on orally administered N-acetylcysteine to healthy volunteers.  相似文献   

20.
We describe a new method to measure free and total malondialdehyde (MDA) in human plasma or serum, which is based on the derivatization of MDA with diaminonaphtalene (DAN) in an acidic medium at 37 degrees C. Derivatization is complete after 180 min at room temperature. By HPLC separation on a C18 column and diode array detection, the diazepinium thus formed exhibits a highly specific UV spectrum with a sharp maximum at 311 nm, which clearly distinguishes MDA from other short-chain aldehydes. Direct injection of deproteinized plasma avoids the use of an internal standard. The between-run imprecision is 9.1% (141 +/- 13 nM) for plasma and 6.6% (658 +/- 44 nM) for a commercial control. Typical within-day imprecision is 8% (93 +/- 7.5 nM) for total MDA, 3.2% (16 +/- 0.5 nM) for free MDA in plasma, and 1.6% (630 +/- 10 nM) for a commercial control. The recovery of MDA added to 10 different plasmas is 93-108% (mean = 100%). Plasma levels in healthy women (n = 79, 45-51 years) are 162 +/- 51 and 24 +/- 15 nM for total and free MDA, respectively. In younger men (n = 19, 21-37 years) total and free MDA are, respectively, 138 +/- 28 and 19 +/- 9 nM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号