首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Reduction of the range of motion (ROM) until prosthetic impingement of a total hip replacement may lead to frequent impingement, subluxation and dislocation especially for patients with good hip movement. The ROM until prosthetic impingement can be calculated using the technical ROM (theta) and the cup and neck positions by a previously created mathematical formula. A larger (theta) with proper cup and neck positions results in a larger ROM. However there was only one paper written in English, which revealed the optimum theoretical combination of cup and neck anteversions. ROM of more than 110 degrees flexion, 30 degrees internal-rotation at 90 degrees flexion, 30 degrees extension and 40 degrees external-rotation were defined as the criteria for essential ROM for ADL. The safe-zones for combined cup anteversion (betaanat) and neck anteversion (b) were defined as the areas that fulfill all the criteria of ROM without prosthetic impingement. The safe-zones were created for 35 degrees , 45 degrees and 55 degrees cup abductions (alpha) and for 120 degrees and 135 degrees (theta). The safe-zones for combined (betaanat) and (b) were much larger for a 135 degrees (theta) than a 120 degrees (theta). Their safe-zones showed that (b) should be reduced if (betaanat) is increased and choosing a lower (alpha) requires that the sum of (betaanat) and (b) should be higher and vice versa. A (theta) of more than 135 degrees is recommended as it further increases the size of the safe-zone and provides a larger ROM, and the optimum values of combined cup and neck anteversions can be estimated by the formula: (alpha) + (betaanat) + 0.77(b) = 84.3.  相似文献   

2.
The range of motion (ROM) of total hip prostheses is influenced by a number of parameters. An insufficient ROM may cause impingement, which may result in subluxation, dislocation or material failure of the prostheses. In a three-dimensional CAD simulation, the position of the centre of rotation and the CCD angle of the stem were investigated. Displacement of the centre of rotation of the femoral head may be due to wear (PE cups) or to the design of the prosthesis (ceramic cups). Stems of widely differing design have been developed and implanted. The results of the present study demonstrate that the ROM is clearly reduced by increasing penetration of the femoral head. At an inclination angle of 45 degrees, a depth of penetration of 2 mm restricts flexion by about 15 degrees, and a depth of penetration of 3 mm by about 30 degrees. At smaller angles of inclination the ROM is reduced and flexion and abduction are associated with an increased risk of impingement. With steeper acetabular cup inclinations, the risk of impingement decreases, but dislocation, the risk of rim fractures (ceramic cups), and wear and penetration rates (PE cups) increase. The CCD angle of the stem should be oriented to the anatomical situation. At high CCD angles (> 135 degrees), flexion is clearly limited, in particular when there is penetration of the femoral head. For modern total hip arthroplasty, prosthetic systems characterised by precise positioning of components, minimum wear, slightly recessed inserts, and appropriate CCD angles should be used.  相似文献   

3.
The present investigation focuses on total hip replacement using ceramic acetabular components. The relationship between the position of the cup and the range of motion (ROM) was investigated. A limited range of motion may cause impingement, which is defined as contact between the femoral neck and the rim of the acetabular cup. Impingement may result in wear, chipping, fracture or dislocation of the femoral head. Joint movements were simulated in a three-dimensional CAD program. The results obtained underscore the importance of correct positioning and design of the cup for achieving a ROM as close to the physiological situation as possible. With ceramic cups, the inclination angle should not be more than 45 degrees, and the antetorsion angle between 10 and 15 degrees. If the cup is too vertical, the risk of dislocation and fracture of the ceramic increases. If, on the other hand, the angle of inclination is too small, flexion and abduction will be greatly limited. The study shows that acetabular components with non-recessed ceramic inserts should not be used. Slight recession of the insert helps to avoid impingement. The ROM is reduced and the risk of impingement appreciably increased when mushroom-shaped femoral heads (XL heads) or ceramic inserts protected by a polyethylene ring are used.  相似文献   

4.
The reduced range of motion (ROM) resulting from total hip replacement (THR) leads to frequent prosthetic impingement, which may restrict activities of daily living and cause subluxation and dislocation. Therefore, to know the ROM of THR is very important in clinical situations and in the design of prostheses. THR involves a pure ball and socket joint. We created a mathematical formula to calculate the theoretical ROM of THR limited by the prosthetic impingement. The ROM of THR is governed by the following five factors, (1) The prosthetic ROM (oscillation angle: obtained from company data), (2) cup abduction (3) cup anterior opening, (4) the angle of the femoral neck component from the horizontal plane, and (5) the femoral neck anteversion. The last 4 factors are able to be obtained from anterior-posterior, axial X-rays and CT of the patient's THR. The objective was to create mathematical formulas that could accurately and quickly calculate the ROM of THR. By entering the five values into a computer programmed with the formulas, one could obtain the ROM for the THR. This reveals the effect on ROM of the oscillation angle and the interaction of ROM with cup abduction, anterior opening and neck anteversion. Furthermore this readily would enable a clinical evaluation of the possibility of postoperative dislocation and help in postoperative rehabilitation. The calculated numerical values of ROM by these mathematical formulas were successfully compared with the ROMs obtained from 3-dimensional computer graphics (3D-CG).  相似文献   

5.
Quantifying soft-tissue tension around the hip joint during total hip arthroplasty remains difficult. In this study, a three-dimensional computer-aided design model was developed to clarify how component position in total hip arthroplasty contributes to the primary cause of posterior dislocation in cases of flexion, adduction and internal rotation. To better understand the influences of anteversion angle of the acetabular component, its effects on the primary causes of dislocations and the range of motion were investigated. Three different primary dislocation mechanisms were noted: impingement of the prosthetic femoral neck on the cup liner; impingement of the osseous femur on the osseous pelvis; and spontaneous dislocation caused by soft-tissue traction without impingement. Spontaneous dislocation could be detected by calculating hip forces at any thigh position using the computer-aided design model developed. In computer analysis, a transition from prosthetic impingement rate to osseous impingement rate occurred with increasing anteversion angle of the acetabular component. Spontaneous dislocation was detected at angles > 10° of anteversion of the acetabular component when flexion occurred with extreme adduction and internal rotation. This study demonstrated the possibility of spontaneous dislocation that results not from prosthetic or bony impingement but from muscle traction with increased range of motion.  相似文献   

6.
Proper cup alignment is crucial in total hip arthroplasty for reducing impingement risks, dislocations and wear. The Lewinnek “safe zone” is often used in clinical routine. This safe zone does not consider functional aspects and dislocation can occur even when the cup is oriented within the safe zone. Functional safe zones based on the hip range of motion (ROM) were introduced but are not commonly used in clinical routine. The reason might be that these methods are time-consuming due to complex simulations. A relatively fast method based on analytical mathematical formulas was proposed, but it is difficult to consider arbitrary motion. This work introduces an efficient algorithm for calculating a patient-specific target zone based on the target ROM which can consider any set of motions. The method is based on matrix transformations and trigonometric formulas. The resulting target zone which contains all impingement-free cup orientations is dependent on the patient-specific pelvic tilt, the 3D angular neck and stem orientation within the femur, and the technical prosthesis ROM. This method could be integrated into computer-assisted preoperative planning and intra-operative navigation tools. As pelvic tilt and stem orientation influence the optimal cup orientation they need to be acquired from the patient to derive a patient-specific ROM-based target zone.  相似文献   

7.
Reduced range of motion, prosthetic impingement, and joint dislocation can all result from misalignment of the acetabular component (i.e. cup alignment) in patients undergoing total hip arthroplasty. Most methods for acetabular component alignment are designed to provide 45-50 degrees abduction and 15-25 degrees of operative anteversion (also known as flexion) with respect to the anterior pelvic plane coordinate system. Yet in most cases, this coordinate system is not assigned properly, due to differences in patient anatomy and improper positioning in the operating room. This misalignment can result in an error in the cup alignment, which can cause the above-mentioned consequences. This work presents a complete mathematical formulation for the analysis of the inaccuracies related to the anterior pelvic plane axes (APPA) definition and their effect on final cup orientation. We do this by introducing a method taken from Kinematics of Mechanisms, and by representing the errors in the APPA as three concurrent axes of rotation, followed by the version and abduction rotations which are defined relative to the previous rotations. We also present a sensitivity analysis of the results by introducing differential changes between sequential coordinate frames, which simulates the errors in the APPA and their effect on cup orientation. Finally, we demonstrate a computational method which provides corrected version and abduction angles to achieve the desired cup orientation, given that the actual measurement errors are known.  相似文献   

8.
After total hip replacement (THR) impingement of the implant components causes shear stresses at the acetabular implant-bone interface. In the current study the finite element method (FEM) was applied to analyse the shear stresses at a fully bonded implant-bone interface assuming total ingrowth of the cup. The FE model of a press-fit acetabular component and the proximal part of the femoral component incorporates non-linear material and large sliding contact. The model was loaded with a superior-medial joint load of 435 N simulating a two-legged stance. Starting at initial impingement, the femoral component was medially rotated by 20 degrees . The peak tilting shear stress of -2.6 MPa at the impingement site takes effect towards the pole of the cup. The torsional shear stress at the impingement site is zero. On each side of the impingement site, there are extrema of torsional shear stress reaching -1.8 and 1.8 MPa, respectively. The global peak shear stress during impingement may indicate a possible starting point for cup loosening. The pattern of the torsional shear stresses suggests that besides the symmetric lever-out, an additional asymmetrical tilting of the cup occurs that can be explained by the orientation of the applied joint load.  相似文献   

9.
Stretching exercise is effective for increasing joint range of motion (ROM). However, the Surgeon General's Report and the American College of Sports Medicine cite a lack of studies identifying strategies capable of increasing the effectiveness of stretching exercise. This investigation evaluated adding modest weight (0.45-1.35 kg) to a stretching exercise routine (Body Recall [BR]) on joint ROM. Forty-three subjects ages 55-83 years participated in 1 of 2 training groups, BR, BR with weights (BR+W), or a control group (C). ROM was evaluated at the neck, shoulder, hip, knee, and ankle before and after 10 weeks of exercise. Using ANCOVA, significant differences (p < 0.01) were observed for right and left cervical rotation, hip extension, ankle dorsiflexion, ankle plantar flexion, and shoulder flexion. Post hoc analysis revealed that cervical rotation (left and right), hip extension, and ankle dorsiflexion for BR+W subjects differed significantly from BR and C (p < 0.01). Significant differences with shoulder flexion and ankle plantar flexion were found for both BR and BR+W in comparison to C (p < 0.01). Results indicate that addition of weights enhanced the effectiveness of stretching exercise for increasing joint ROM with 4 of the 6 selected measurements. Thus, a modest intensity exercise program that is within the reach of most elderly may significantly affect joint ROM and flexibility.  相似文献   

10.
After total hip arthroplasty, impingement of implant components may occur during every-day patient activities causing increased shear stresses at the acetabular implant-bone interface. In the literature, impingement related lever-out moments were noted for a number of acetabular components. But there is little information about pelvic load transfer. The aim of the current study was to measure the three-dimensional strain distribution at the macrostructured hemispherical interface and in the periphery of a standard acetabular press-fit cup in an experimental implant-bone substitute model. An experimental setup was developed to simulate impingement loading via a lever arm representing the femoral component and the lower limb. In one experimental setup 12 strain gauges were embedded at predefined positions in the periphery of the acetabular cup implant inside a tray, using polyurethane composite resin as a bone substitute material. By incremental rotation of the implant tray in steps of 10 and 30 deg, respectively, the strains were measured at evenly distributed positions. With the described method 288 genuine strain values were measured in the periphery of an embedded acetabular cup implant in one experimental setup. In two additional setups the strains were evaluated at different distances from the implant interface. Both in radial and meridional interface directions strain magnitudes reach their peak near the rim of the cup below the impingement site. Values of equatorial strains vary near zero and reach their peaks near the rim of the cup on either side and in some distance from the impingement site. Interestingly, the maximum of averaged radial strains does not occur, as expected, close to the interface but at an interface offset of 5.6 mm. With the described experimental setup it is now possible to measure and display the three-dimensional strain distribution in the interface and the periphery of an embedded acetabular cup implant. The current study provides the first experimental proof of the high local stresses gradients in the direct vicinity of the impingement site. The results of the current study help for a better understanding of the impingement mechanism and its impact on acetabular cup stability.  相似文献   

11.
Accuracy of an image-free cup navigation system--an anatomical study]   总被引:2,自引:0,他引:2  
The position of the acetabular cup is of decisive importance for the function of a total hip replacement (THR). Using the conventional surgical technique, correct placement of the cup often fails due to a lack of information about pelvic tilt. With CT-based and fluoroscopically-assisted navigation procedures the accuracy of implantation has been significantly improved. However, additional radiation exposure, high cost and the increased time requirement have hampered the acceptance of these techniques. The present anatomical study evaluates the accuracy of an alternative procedure--image-free navigation. This method requires little extra effort, does not substantially delay surgery, and needs no additional imaging. Press-fit cups were implanted in 10 human cadaveric hips with the help of the image-free navigation system, and the position of the cups was checked intraoperatively with a CT-based navigation system and postoperatively by computed tomography. All cups were implanted within the targeted safe zone with an average inclination of 44 degrees (range 40 degrees-48 degrees, SABW 2.7 degrees) and an average anteversion of 18 degrees (range 12-24 degrees, SABW 4.1 degrees). Analysis of accuracy of the image-free navigation software revealed only a small, clinically tolerable deviation in cup anteversion and cup inclination in comparison with the CT-based navigation system and the post operative CT scans. The evaluated image-free navigation system appears to be a practicable and reliable alternative to the computer-assisted implantation of acetabular cups in total hip arthroplasty.  相似文献   

12.
Limited plantar flexor strength and hip extension range of motion (ROM) in older adults are believed to underlie common age-related differences in gait. However, no studies of age-related differences in gait have quantified the percentage of strength and ROM used during gait. We examined peak hip angles, hip torques and plantar flexor torques, and corresponding estimates of functional capacity utilized (FCU), which we define as the percentage of available strength or joint ROM used, in 10 young and 10 older healthy adults walking under self-selected and controlled (slow and fast) conditions. Older adults walked with about 30% smaller hip extension angle, 28% larger hip flexion angle, 34% more hip extensor torque in the slow condition, and 12% less plantar flexor torque in the fast condition than young adults. Older adults had higher FCU than young adults for hip flexion angle (47% vs. 34%) and hip extensor torque (48% vs. 27%). FCUs for plantar flexor torque (both age groups) and hip extension angle (older adults in all conditions; young adults in self-selected gait) were not significantly <100%, and were higher than for other measures examined. Older adults lacked sufficient hip extension ROM to walk with a hip extension angle as large as that of young adults. Similarly, in the fast gait condition older adults lacked the strength to match the plantar flexor torque produced by young adults. This supports the hypothesis that hip extension ROM and plantar flexor strength are limiting factors in gait and contribute to age-related differences in gait.  相似文献   

13.
Dislocation of the artificial joint is a serious complication of total hip replacement. Various factors with an influence on dislocation stability were determined clinically. Our goal was to develop a method for evaluating experimentally the parameters implant design, position and the load situation for their influence on joint stability. With the newly developed testing device the range of motion to impingement and to dislocation can be determined at different implant positions. In addition, the rotational moments on subluxation, i.e. the "levering out" of the femoral head, can be determined. By way of example several hip implants were examined during movements associated with dislocation, e.g. (internal-)rotation in 90 degrees flexion and 0 degrees adduction as well as with (external-)rotation in combination with 10 degrees extension and 15 degrees adduction. Irrespective of implant design and position, the following movement phases can be differentiated: undisturbed motion, impingement, subluxation and, finally, complete dislocation of the head. On the basis of the range of motion of the specific phases, the moments occurring and the direction of dislocation, different implant systems can be compared. In this study the influence of the head diameter on the dislocation stability of the hip endoprosthesis is shown. With the aid of the model presented herein, a data set showing the most favourable and/or most dislocation stable implant position can be acquired for different combinations of the implant components. Additionally, useful information for implant design can be deduced and applied to new developments and/or modifications of existing implant components.  相似文献   

14.
The joint fluid mechanics and transport of wear particles in the prosthetic hip joint were analyzed for subluxation and flexion motion using computational fluid dynamics (CFD). The entire joint space including a moving capsule boundary was considered. It was found that particles suspended in the joint space are drawn into the joint gap between prosthesis cup and head during subluxation, which was also documented by Lundberg et al. (2007; Journal of Biomechanics 40, 1676-1685), however, wear particles remain in the joint gap. Wear particles leave the joint gap during flexion and can finally migrate to the proximal boundaries including the acetabular bone, where the particle deposition can cause osteolysis according to the established literature. Thus, the present study supports the theory of polyethylene wear particle induced osteolysis of the acetabular bone as a major factor in the loosening of hip prosthesis cups.  相似文献   

15.
The patella groove of total knee replacements has evolved from a groove with a neutral orientation to a groove with a lateral (also referred to as valgus) orientation. In this study the authors questioned whether femoral components with a lateral groove orientation more closely approximate the configuration in the natural knee. The groove orientations of an implanted CKS femoral component, available in different sizes and with different groove orientations, were determined and compared with formerly published measurements of the natural trochlear orientation. It was found that the prosthetic groove orientations differed considerably from human anatomy, up to a maximum deviation of 6.4 degrees. The orientations of the prosthetic grooves were all equal within the area of the natural trochlea. The area of the natural trochlea guides the patella between about 30 degrees and 120 degrees of knee flexion. The orientations of the prosthetic grooves were different in the area of the supracondylar pouch/proximal anterior flange. This area guides the patella between about 0 degrees and 30 degrees of knee flexion. As this study showed a considerable deviation between natural and prosthetic groove orientation, an optimal prosthetic groove orientation, matching the average orientation in the natural knee, was mathematically determined.  相似文献   

16.
The objective of this study was to test the hypothesis that the human lumbosacral joint behaves differently from L1-L5 joints and provides primary moment-rotation responses under pure moment flexion and extension and left and right lateral bending on a level-by-level basis. In addition, range of motion (ROM) and stiffness data were extracted from the moment-rotation responses. Ten T12-S1 column specimens with ages ranging from 27 to 68 years (mean: 50.6+/-13.2) were tested at a load level of 4.0 N m. Nonlinear flexion and extension and left and right lateral bending moment-rotation responses at each spinal level are reported in the form of a logarithmic function. The mean ROM was the greatest at the L5-S1 level under flexion (7.37+/-3.69 degrees) and extension (4.62+/-2.56 degrees) and at the L3-L4 level under lateral bending (4.04+/-1.11 degrees). The mean ROM was the least at the L1-L2 level under flexion (2.42+/-0.90 degrees), L2-L3 level under extension (1.58+/-0.63 degrees), and L1-L2 level under lateral bending (2.50+/-0.75 degrees). The present study proved the hypothesis that L5-S1 motions are significantly greater than L1-L5 motions under flexion and extension loadings, but the hypothesis was found to be untrue under the lateral bending mode. These experimental data are useful in the improved validation of FE models, which will increase the confidence of stress analysis and other modeling applications.  相似文献   

17.
Most biomechanical studies of the knee have focused on knee flexion angles between 0 degrees and 120 degrees. The posterior cruciate ligament (PCL) has been shown to constrain posterior laxity of the knee in this range of flexion. However, little is known about PCL function in higher flexion angles (greater than 120 degrees ). This in vitro study examined knee kinematics before and after cutting the PCL at high flexion under a posterior tibial load and various muscle loads. The results demonstrated that although the PCL plays an important role in constraining posterior tibial translation at low flexion angles, the PCL had little effect in constraining tibial translation at 150 degrees of flexion under the applied loads.  相似文献   

18.
The aim of this study was to compare the effects of static stretching, proprioceptive neuromuscular facilitation (PNF) stretching and Mulligan technique on hip flexion range of motion (ROM) in subjects with bilateral hamstring tightness. A total of 40 students (mean age: 21.5±1.3 years, mean body height: 172.8±8.2 cm, mean body mass index: 21.9±3.0 kg · m-2) with bilateral hamstring tightness were enrolled in this randomized trial, of whom 26 completed the study. Subjects were divided into 4 groups performing (I) typical static stretching, (II) PNF stretching, (III) Mulligan traction straight leg raise (TSLR) technique, (IV) no intervention. Hip flexion ROM was measured using a digital goniometer with the passive straight leg raise test before and after 4 weeks by two physiotherapists blinded to the groups. 52 extremities of 26 subjects were analyzed. Hip flexion ROM increased in all three intervention groups (p<0.05) but not in the no-intervention group after 4 weeks. A statistically significant change in initial–final assessment differences of hip flexion ROM was found between groups (p<0.001) in favour of PNF stretching and Mulligan TSLR technique in comparison to typical static stretching (p=0.016 and p=0.02, respectively). No significant difference was found between Mulligan TSLR technique and PNF stretching (p=0.920). The initial–final assessment difference of hip flexion ROM was similar in typical static stretching and no intervention (p=0.491). A 4-week stretching intervention is beneficial for increasing hip flexion ROM in bilateral hamstring tightness. However, PNF stretching and Mulligan TSLR technique are superior to typical static stretching. These two interventions can be alternatively used for stretching in hamstring tightness.  相似文献   

19.
In 17 patients with unilateral hip disease who underwent total hip arthroplasty (THA), the gait was analyzed preoperatively and 1, 3, 6, and 12 months after unilateral THA using a Vicon system to assess the recovery of walking speed and symmetrical movement of the hip, knee, ankle, and pelvis. The walking speed of these patients reached that of normal Japanese persons by 12 months after surgery. Walking speed was correlated with the range of hip motion on the operated side at 1 month postoperatively, and was correlated with the hip joint extension moment of force on both sides from 3 to 6 months after surgery. Before THA, asymmetry was observed in the range of the hip motion, maximum hip flexion, maximum hip extension, maximum knee flexion, as well as in pelvic obliquity, pelvic tilt, and pelvic rotation. There were no differences of the stride length or step length between both sides throughout the observation period. The preoperative range of hip flexion on the operated side during a gait cycle (21.3+/-7.9 degrees ) was significantly smaller than on the non-operated side (46.7+/-7.1 degrees ), and the difference between sides was still significant at 12 months after surgery (35.1+/-6.2 degrees on the operated side and 43.6+/-5.7 degrees on the non-operated side). The majority (74%) of the difference in hip motion range during this period was due to the difference in maximum extension of the hip. The increase in the range of pelvic tilt and the range of motion of the opposite hip showed an inverse correlation with the range of motion of the operated hip, suggesting a compensatory preoperative role. However, this correlation became insignificant after 6 months postoperatively. Asymmetry of the range of hip motion persisted at 12 months after THA in patients with unilateral coxoarthropathy during free level walking, while the operation normalized the spatial asymmetry of other joints and the walking speed prior to the recovery of hip motion.  相似文献   

20.
Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号