首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The DF-4 is a new defibrillator lead technology. We present two cases of non-physiological transient ventricular over-sensing in patients who underwent implantation of an ICD for secondary prevention. Case 1 had ventricular over-sensing during pacing threshold evaluation post defibrillation testing while Case 2 had the lead integrity alert triggered immediately post discharge with transient over-sensing. No lead-connector issues were found. Case 1 was likely due to improper venting of the header and trapped air. Case 2 was hypothesized to be due to intermittent header pin non-contact secondary to blood in the header. These cases reveal that DF-4 leads are subject to both reported and potentially novel causes of transient acute ventricular over-sensing.  相似文献   

2.
3.
Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.  相似文献   

4.
Electromagnetic interferences (EMI) deriving from electrical devices may affect implantable cardioverter defibrillators (ICD). Improved algorithms have been developed in order to minimize adverse effects. However, caution should be still recommended in ICD recipients when handling electrical devices. Here we describe the case of an ICD patient with recurrent syncopal episodes due to inhibition of pacing by oversensing of electrical noise from a not properly grounded washing machine.  相似文献   

5.

Aims

Atrial fibrillation (AF) and heart failure are conditions that often coexist. Consequently, many patients with an implantable cardioverter-defibrillator (ICD) present with AF. We evaluated the effectiveness of internal cardioversion of AF in patients with an ICD.

Methods

Retrospectively, we included 27 consecutive ICD patients with persistent AF who underwent internal cardioversion using the ICD. When ICD cardioversion failed, external cardioversion was performed.

Results

Patients were predominantly male (89 %) with a mean (SD) age of 65 ± 9 years and left ventricular ejection fraction of 36 ± 17 %. Only nine (33 %) patients had successful internal cardioversion after one, two or three shocks. The remaining 18 patients underwent external cardioversion after they failed internal cardioversion, which resulted in sinus rhythm in all. A smaller left atrial volume (99 ± 36 ml vs. 146 ± 44 ml; p = 0.019), a longer right atrial cycle length (227 (186–255) vs. 169 (152–183) ms, p = 0.030), a shorter total AF history (2 (0–17) months vs. 40 (5–75) months, p = 0.025) and dual-coil ICD shock (75 % vs. 26 %, p = 0.093) were associated with successful ICD cardioversion.

Conclusion

Internal cardioversion of AF in ICD patients has a low success rate but may be attempted in those with small atria, a long right atrial fibrillatory cycle length and a short total AF history, especially when a dual-coil ICD is present. Otherwise, it seems reasonable to prefer external over internal cardioversion when it comes to termination of persistent AF.  相似文献   

6.
The cutdown technique for the cephalic vein is a common access route for transvenous cardiac device leads (TVLs), and sometimes one cephalic vein can accomodate two TVLs. We examined a novel ligation technique to balance the hemostasis and lead maneuverability for this two-in-one insertion. A total of 22 patients scheduled for cardiac device implantations with two or more leads were enrolled. The ipsilateral cephalic vein was identified for inserting the TVLs with a cutdown. If two TVLs could be introduced into one cephalic vein, hemostasis was established by ligating the venous wall between the TVLs. We measured the amount of hemorrhaging per minute and the operators assessed the lead maneuverability before and after the ligation. We successfully implanted cardiac devices in 15 patients (68%) with this novel method, whereas only one TVL could be introduced via the cephalic vein in 7 patients. As for the successful patients, hemorrhaging from the gap was significantly reduced (5.6?±?7.3 to 0.41?±?0.36g/min, p?=?0.016) after the novel ligation. The lead maneuverability was well maintained so there was no difficulty placing the leads into the cardiac chambers in all cases. No major complications were observed. In the present study, the novel ligation method provided significant hemostasis as well as a preserved maneuverability. It could be an optional choice for insertion of multiple TVLs.  相似文献   

7.
Central venous obstruction following pacemaker implantation is not uncommon, and can prove challenging in the case of system upgrade. We report a case of DDDR to CRT-P (with multi-site pacing) upgrade, where a subclavian occlusion was overcome resorting to an atrial lead extraction (using only a locking stylet). This allowed regaining of the venous access with subsequent implantation of not just one, but two new leads and subsequent successful upgrade.  相似文献   

8.
The lifesaving benefits of implantable cardioverter defibrillator (ICD) therapy are more and more weighted against possible harm (e.g. unnecessary device therapy, procedural complications, device malfunction etc.) which might have adverse effects on patients’ perceived health status and quality of life. Hence, there has been an increasing interest in the optimisation of ICD programming to prevent inappropriate and appropriate but unnecessary device therapy. The purpose of the current report is to give an overview of research into the optimisation of ICD programming and present the design of the on-going ENHANCED-ICD study. The ENHANCED-ICD study is a prospective, safety monitoring study enrolling 60 primary and secondary prophylactic ICD patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technologyTM, and between 18–80 years of age, were eligible to participate. In all patients a prolonged detection of 60/80 intervals was programmed. The primary objective of the study is to investigate whether enhanced programming to further reduce ICD therapies is safe. The secondary objective is to examine the impact of enhanced programming on (i) antitachycardia pacing and shocks (both appropriate and inappropriate) and (ii) quality of life and distress. The first results of the ENHANCED-ICD study are expected in 2015.  相似文献   

9.
Background/PurposeTransarterial lead implantation in the left ventricle or aorta is a rare complication. Percutaneous lead removal is associated with significant thromboembolic and bleeding risk. We present two cases of lead removal from the left ventricle via the left subclavian artery with concurrent carotid embolic protection followed by stent graft placement in the subclavian artery.Methods/ResultsPatient 1 underwent prior pacemaker implant with atrial and ventricular active fixation leads positioned in the right coronary cusp and the left ventricle, respectively. Patient 2 had prior ICD implant with a single active fixation lead positioned in the left ventricular apex. Lead removal was performed in a hybrid operating room. Distal embolic filter wires were deployed in the carotid arteries following anticoagulation. Intravascular ultrasound of the left subclavian artery was performed and as the leads were withdrawn, a covered stent was deployed at the removal site. Final angiography demonstrated no evidence of embolic phenomena. Both patients underwent transvenous lead implantation followed by an uneventful postoperative clinical course.ConclusionsTransarterial percutaneous lead removal may be safely performed using embolic filter protection of the cerebral circulation and stent graft placement of the arterial entry site.  相似文献   

10.
With the increasing number of cardiovascular implantable electronic device upgrade and vein obstruction caused by previous leads, it is important to have alternative techniques to upgrade the device with the maintenance of functioning leads.We report an 83-year old male with 13-year old one-lead dual-chamber pacemaker, ischemic cardiac disease and pre-dialytic chronic kidney disease submitted to an upgrade to cardiac resynchronization therapy. A sub-occlusion in the transition of left brachiocephalic vein and the superior vena cava was documented. Re-permeabilization was only achieved with a TightRail? rotating dilator sheath over a guidewire with successful left ventricle lead implant.  相似文献   

11.

Background

The benefit of implantable defibrillators (ICDs) for primary prevention remains debated. We analysed the implications of prophylactic ICD implantation according to the guidelines in 2 tertiary hospitals, and made a healthcare utilisation inventory.

Methods

The cohort consisted of all consecutive patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM) receiving a primary prophylactic ICD in a contemporary setting (2004–2008). Follow-up was obtained from hospital databases, and mortality checked at the civil registry. Additional data came from questionnaires sent to general practitioners.

Results

There were no demographic differences between the 2 centres; one had proportionally more CAD patients and more resynchronisation therapy (CRT-D). The 587 patients were followed over a median of 28 months, and 50 (8.5%) patients died. Appropriate ICD intervention occurred in 123 patients (21%). There was a small difference in intervention-free survival between the 2 centres. The questionnaires revealed 338 hospital admissions in 52% of the responders. Device-related admissions happened on 68 occasions, in 49/276 responders. The most frequently reported ICD-related admission was due to shocks (20/49 patients); for other cardiac problems it was mainly heart failure (52/99). Additional outpatient visits occurred in 19%.

Conclusion

Over a median follow-up of 2 years, one fifth of prophylactic ICD patients receive appropriate interventions. A substantial group undergoes readmission and additional visits. The high number of admissions points to a very ill population. Overall mortality was 8.5%. The 2 centres employed a similar procedure with respect to patient selection. One centre used more CRT-D, and observed more appropriate ICD interventions.  相似文献   

12.
This case report describes how new tools and technologies can drive a different approach in the management of arrhythmic patients. An unknown and asymptomatic atrial flutter was detected by the atrial sensor mounted in a single lead implantable cardioverter defibrillator. Moreover daily remote monitoring of the device allowed early notification and prompt clinical reaction. Anticoagulant therapy onset, radiofrequency ablation and the following anticoagulant therapy removal were driven by the device data transmissions.  相似文献   

13.

Introduction

Survival benefit from ICD implantation is relatively low in primary prevention patients. Better patient selection is important to maintain maximum survival benefit while reducing the number of unnecessary implants. Microvolt T-wave alternans (MTWA) is a promising risk marker. In this study, we aimed to evaluate the predictive value of MTWA in ICD patients.

Methods and results

This study was a substudy of the Twente ICD Cohort Study (TICS). Patients with ischaemic or non-ischaemic left ventricular dysfunction who received an ICD following current ESC guidelines were eligible for inclusion. Exercise-MTWA was performed and classified as non-negative or negative. The primary endpoint was the composite of mortality and appropriate shock therapy. Analysis was performed in 134 patients (81 % male, mean age 62 years, mean ejection fraction 26.5 %). MTWA was non-negative in 64 %. There was no relation between non-negative MTWA testing and mortality and/or appropriate shock therapy (all p-values >0.15). Due to clinical conditions, 24 % were ineligible for testing. These patients experienced the highest risk for mortality (p < 0.01).

Conclusion

Non-negative MTWA testing did not predict mortality and/or appropriate shock therapy. Furthermore, MTWA testing is not feasible in a large percentage of patients. These ineligible patients experience the highest risk for mortality.  相似文献   

14.
Although the conventional methods for endo-cardial pacemaker lead implantation via subclavian or cephalic or axillary vein routes is common, but sometimes due to anatomical variations it is not feasible to access these veins Emergence of newer techniques are useful for lead implantation. This case report focuses on a hybrid approach of combined mini-thoracotomy for endocardial pacemaker lead implantation. This fluoroscopy guided minimal thoracotomy approach with endocardial MRI compatible lead placement had the benefits of simple procedural, minimal hospital stay, low early complication rates and economically viable to the patient.  相似文献   

15.
Summary A compartment model is derived for the kinetics of lead in the human body. The parameters are estimated from field data. Numerical solutions of the equations are obtained. They are used to discuss recent theories on lead intake, in particular from the atmosphere.  相似文献   

16.
The helicoidal plane of dental occlusion is a composite feature involving axial inclination of teeth and effects of dental attrition. Recent studies disagree on its distribution and significance in hominoid primates. The distribution, development, and functional basis of the helicoidal plane are investigated here, based on quantitative analysis of dental morphology and attrition in 667 human and 60 chimpanzee dentitions. Helicoidal planes are nearly universal in the human and chimpanzee dentitions studied. Increasing axial inclination of molars from M1 to M3 is primarily responsible for the helicoidal plane, although attrition acts to increase its expression. In hominoids, increased molar axial tilt appears to be associated with facial shortening and dental reduction. Population and species comparisons suggest a functional relationship with cranial structure. Progressive axial tilt of molars producing a helicoidal plane is found consistently in mammals with cheek teeth positioned partly under the cranium, as in hominids, pongids, some cebids, macropodids, ursids, and sciurids. Facial shortening is an important trend in hominid evolution and axial inclination of molars might be expected to show progressive change from Australopithecus afarensis to recent Homo sapiens.  相似文献   

17.
18.
生物电子等排原理在药物先导化合物优化中的应用   总被引:4,自引:0,他引:4  
崔永梅  南发俊 《生命科学》2006,18(2):161-167
先导化合物的优化是新药研究和开发的重要环节。由于先导化合物只提供一种具有特定药理作用的新结构类型,往往由于在药理、药效学、药代动力学等方面的缺点或不足而不能直接用于临床。因此,需要对先导化合物进行进一步化学结构改造或修饰,以期优化上述特性。“生物电子等排取代(bioisostericreplacement)”即为对先导化合物进行合理优化的有效策略之一。本文简要综述了生物电子等排原理在药物先导化合物优化中的应用。  相似文献   

19.
Biosynthesis of nanoparticles using microorganisms has attracted a lot of attention in recent years as this route has the potential to lead to synthesis of monodisperse nanoparticles. Here, we report the intracellular synthesis of stable lead sulfide nanoparticles by a marine yeast, Rhodosporidium diobovatum. The PbS nanoparticles were characterized by UV-visible absorption spectroscopy, X-ray diffraction (XRD) and energy dispersive atomic spectroscopy (EDAX). UV-visible absorption scan revealed a peak at 320 nm, a characteristic of the nanosize range. XRD confirmed the presence of PbS nanoparticles of cubic structure. Crystallite size as determined from transmission electron microscopy was found to be in the range of 2-5 nm. Elemental analysis by EDAX revealed the presence of particles composed of lead and sulfur in a 1:2 ratio indicating that PbS nanoparticles were capped by a sulfur-rich peptide. A quantitative study of lead uptake through atomic absorption spectrometry revealed that 55% of lead in the medium was accumulated in the exponential phase, whereas a further 35% was accumulated in the stationary phase; thus, the overall recovery of PbS nanoparticles was 90%. The lead-exposed yeast displayed a marked increase (280% over the control) in nonprotein thiols in the stationary phase.  相似文献   

20.
Triethyl lead is the major metabolite of tetraethyl lead, which is used in industrial processes and as an antiknock additive to gasoline. We tested the hypothesis that low levels of triethyl lead (0.1 nmol/L to 5mol/L) interfere with the normal development of cultured E18 rat hippocampal neurons, possibly through increases in intracellular free calcium ion concentration, [Ca2+]in. The study assessed survival and differentiation using morphometric analysis of individual neurons. We also looked at short-term (up to 3.75-h) changes in intracellular calcium using the calcium-sensitive dye fura-2. Survival of neurons was significantly reduced at 5 mol/L, and overall production of neurites was reduced at 2 mol/L. The length of axons and the number of axons and dendrites were reduced at 1 mol/L. Neurite branching was inhibited at 10 nmol/L for dendrites and 100 nmol/L for axons. Increases in intracellular calcium were observed during a 3.75-h exposure of newly plated neurons to 5 mol/L triethyl lead. These increases were prevented by BAPTA-AM; which clamps [Ca2+]in at about 100 nmol/L. Culturing neurons with BAPTA-AM and 5 mol/L triethyl lead did not reverse the effects of triethyl lead, suggesting that elevation of [Ca2+]in is not responsible for decreases in survival and neurite production. Triethyl lead has been shown to disrupt cytoskeletal elements, particularly neurofilaments, at very low levels, suggesting a possible mechanism for its inhibition of neurite branching at nanomolar concentrations.Abbreviations BAPTA-AM 1,2-bis(2-aminophenoxy)ethane-N,N,N,N-tetraacetic acid acetoxymethyl ester - [Ca2+]in intracellular free calcium ion concentration - DMSO dimethyl sulfoxide - E18 embryonic day 18 - FBS fetal bovine serum - fura-2AM fura-2 acetoxymethyl ester - HBSS Hanks' Balanced Salt Solution - MEM Eagle's Minimum Essential Medium  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号