首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Enrichment is essential for phosphoproteome analysis because phosphorylated proteins are usually present in cells in low abundance. Recently, titanium dioxide (TiO2) has been demonstrated to enrich phosphopeptides from simple peptide mixtures with high specificity; however, the technology has not been optimized. In the present study, significant non-specific bindings were observed when proteome samples were applied to TiO2 columns. Column wash with an NH4Glu solution after loading peptide mixtures significantly increased the efficiency of TiO2 phosphopeptide enrichment with a recovery of up to 84%. Also, for proteome samples, more than a 2-fold increase in unique phosphopeptide identifications has been achieved. The use of NH4Glu for a TiO2 column wash does not significantly reduce the phosphopeptide recovery. A total of 858 phosphopeptides corresponding to 1034 distinct phosphosites has been identified from HeLa cells using the improved TiO2 enrichment procedure in combination with data-dependent neutral loss nano-RPLC-MS2-MS3 analysis. While 41 and 35% of the phosphopeptides were identified only by MS2 and MS3, respectively, 24% was identified by both MS2 and MS3. Cross-validation of the phosphopeptide assignment by MS2 and MS3 scans resulted in the highest confidence in identification (99.5%). Many phosphosites identified in this study appear to be novel, including sites from antigen Ki-67, nucleolar phosphoprotein p130, and Treacle protein. The study also indicates that evaluation of confidence levels for phosphopeptide identification via the reversed sequence database searching strategy might underestimate the false positive rate.  相似文献   

2.
IMAC in combination with mass spectrometry is a promising approach for global analysis of protein phosphorylation. Nevertheless this approach suffers from two shortcomings: inadequate efficiency of IMAC and poor fragmentation of phosphopeptides in the mass spectrometer. Here we report optimization of the IMAC procedure using (32)P-labeled tryptic peptides and development of MS/MS/MS (MS3) for identifying phosphopeptide sequences and phosphorylation sites. The improved IMAC method allowed recovery of phosphorylated tryptic peptides up to approximately 77% with only minor retention of unphosphorylated peptides. MS3 led to efficient fragmentation of the peptide backbone in phosphopeptides for sequence assignment. Proteomics of mitochondrial phosphoproteins using the resulting IMAC protocol and MS3 revealed 84 phosphorylation sites in 62 proteins, most of which have not been reported before. These results revealed diverse phosphorylation pathways involved in the regulation of mitochondrial functions. Integration of the optimized batchwise IMAC protocol with MS3 offers a relatively simple and more efficient approach for proteomics of protein phosphorylation.  相似文献   

3.
4.
An overview is presented of gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), the two major hyphenated techniques employed in metabolic profiling that complement direct 'fingerprinting' methods such as atmospheric pressure ionization (API) quadrupole time-of-flight MS, API Fourier transform MS, and NMR. In GC/MS, the analytes are normally derivatized prior to analysis in order to reduce their polarity and facilitate chromatographic separation. The electron ionization mass spectra obtained are reproducible and suitable for library matching, mass spectral collections being readily available. In LC/MS, derivatization and library matching are at an early stage of development and mini-reviews are provided. Chemical derivatization can dramatically increase the sensitivity and specificity of LC/MS methods for less polar compounds and provides additional structural information. The potential of derivatization for metabolic profiling in LC/MS is demonstrated by the enhanced analysis of plant extracts, including the potential to measure volatile acids such as formic acid, difficult to achieve by GC/MS. The important role of mass spectral library creation and usage in these techniques is discussed and illustrated by examples.  相似文献   

5.
6.
Recent technological advances have made available reverse phase chromatographic media with a 1.7 microm particle size along with a liquid handling system that can operate such columns at much higher pressures. This technology, termed ultra performance liquid chromatography (UPLC), offers significant theoretical advantages in resolution, speed, and sensitivity for analytical determinations, particularly when coupled with mass spectrometers capable of high-speed acquisitions. This paper explores the differences in LC-MS performance by conducting a side-by-side comparison of UPLC for several methods previously optimized for HPLC-based separation and quantification of multiple analytes with maximum throughput. In general, UPLC produced significant improvements in method sensitivity, speed, and resolution. Sensitivity increases with UPLC, which were found to be analyte-dependent, were as large as 10-fold and improvements in method speed were as large as 5-fold under conditions of comparable peak separations. Improvements in chromatographic resolution with UPLC were apparent from generally narrower peak widths and from a separation of diastereomers not possible using HPLC. Overall, the improvements in LC-MS method sensitivity, speed, and resolution provided by UPLC show that further advances can be made in analytical methodology to add significant value to hypothesis-driven research.  相似文献   

7.
Lisacek F 《Proteomics》2006,6(Z2):22-32
This tutorial focuses on three MS/MS data analysis programs currently available via a web interface: Mascot, Phenyx and X!Tandem. Although these programs process the same input and often produce comparable outputs, subtle differences remain. The use of parameters that are requested in the on-line forms and the subsequent interpretation of results are illustrated and explained via a single example.  相似文献   

8.
Characterization of betaines using electrospray MS/MS   总被引:3,自引:0,他引:3  
Betaines are an important class of naturally occurring compounds that function as compatible solutes or osmoprotectants. Because of the permanent positive charge on the quaternary ammonium moiety, mass spectrometric analysis has been approached by desorption methods, including fast atom bombardment and plasma desorption mass spectrometry. Here we show that electrospray ionization MS gives comparable results to plasma desorption MS for a range of authentic betaine standards and betaines purified from plant extracts by ion exchange chromatography. A distinct advantage of electrospray ionization MS over plasma desorption MS is the capability of obtaining product ion spectra via MS/MS of selected parent ions, and hence structural information to discriminate between ions of identical mass.  相似文献   

9.
Biological monitoring is a necessary process for risk assessment of endocrine disrupting chemicals (EDCs), particularly, bisphenol A (BPA), in breast milk, because its human risks are not clear yet, and infants, who feed on breast milk, are highly susceptible for EDCs. Concerning biological monitoring of BPA, the HPLC/FLD has been widely used before the LC/MS/MS. However, there was no report, which simultaneously evaluated the two methods in real analyses. Therefore, we analyzed BPA with LC/MS/MS and HPLC/FLD in human breast milk and conducted comparison of two methods in analyzed BPA levels. After establishing optimal condition, e.g. linearity, recovery, reproducibility and free BPA system, we analyzed BPA levels in human breast milk samples (N = 100). The LOQs were similar in the two methods, i.e. 1.8 and 1.3 ng/mL for the HPLC/FLD and LC/MS/MS assays, respectively. There were strong associations between total BPA levels with the two methods (R2 = 0.40, p < 0.01), however, only 11% of them were analyzed as similar levels with 15% CVs. In addition, the detection range of BPA was broader in the HPLC method than the LC/MS/MS method. However, the BPA levels in the HPLC/FLD analysis were lower than those in the LC/MS/MS analysis (p < 0.01). Thus, the differences in BPA levels between the two methods may come from mainly over-estimation with the LC/MS/MS method in low BPA samples and some of poor resolution with the HPLC/FLD in high BPA samples.  相似文献   

10.
Determination of eprosartan in human plasma and urine by LC/MS/MS   总被引:1,自引:0,他引:1  
A protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of eprosartan in human plasma and urine. The solvent system also served as a protein precipitation reagent. The chromatographic separation was achieved on a CAPCELL PAK C18 column (50 mmx2.0 mm, 5 microm, Shiseido). A mobile phase was consisted of 0.5% formic acid in water and 0.5% formic acid in acetonitrile (72:28). Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API3000. The standard curves, which ranged from 5 to 2000 ng/mL in human plasma and from 0.25 to 50 microg/mL in urine, were fitted to a 1/x weighted quadratic regression model. The method proved to be accurate, specific and sensitive enough to be successfully applied to a pharmacokinetic study.  相似文献   

11.
HPLC coupled with normal phase electron ionisation (EI) and atmospheric pressure chemical ionisation (APCI)/ mass spectrometry methods has been applied to identify 17 known neutral limonoid aglycones from Citrus sources. The HPLC-MS data from the known limonoids provided chromatographic characteristics, APCI-derived molecular weight data and EI fragmentation data for each limonoid. EI fragmentation patterns for the limonoids were correlated with structural characteristics. The EI fragmentation patterns coupled with APCI-derived molecular weights were utilised as a potential method by which to discern the structural character of unknown citrus limonoids.  相似文献   

12.
The subject of this tutorial is protein identification and characterisation by database searching of MS/MS Data. Peptide Mass Fingerprinting is excluded because it is covered in a separate tutorial. Practical aspects of database searching are emphasised, such as choice of sequence database, effect of mass tolerance, and how to identify post-translational modifications. The relationship between sensitivity and specificity is discussed, as is the challenge of using peptide match information to infer which proteins were present in the sample. Since these tutorials are introductory in nature, most references are to reviews, rather than primary research papers. Some familiarity with mass spectrometry and protein chemistry is assumed. There is an accompanying slide presentation, including speaker notes, and a collection of web-based, practical exercises, designed to reinforce key points. This Tutorial is part of the International Proteomics Tutorial Programme (IPTP 6).  相似文献   

13.
14.
目的:建立同时测定大鼠血浆中阿霉素和塞来昔布的液相色谱-串联质谱(LC/MS/MS)方法,研究这两种药物联合应用的药代动力学.方法:大鼠尾静脉注射阿霉素和塞来昔布,眼眶取血并抗凝,离心分离血浆,采用乙酸乙酯提取血浆中的阿霉素和塞来昔布,N2吹干乙酸乙酯,残留物用50μL甲醇溶解,取20μL用于LC/MS/MS分析.结果:用LC/MS/MS法检测大鼠血浆中阿霉素和塞来昔布的线性范围为1-800ng/mL,日内、日间精密度(RSD)均小于15%,检测血浆低、中、高三个浓度(8、50、500ng/mL)阿霉素的回收率分别为101.2%、95.1%和91.4%,检测血浆低、中、高三个浓度(8、50、500ng/mL)塞来昔布的回收率分别为105.6%、106.8%和93.7%.大鼠尾静脉注射5.8mg/kg阿霉素和3.8mg/kg塞来昔布的半衰期分别为2.3 h和3.6h,曲线下面积分别为670 ng·h·mL-1和1480ng·h·mL-1.结论:建立的方法灵敏、准确、快速,适甩于阿霉素和塞来昔布的药代动力学研究.  相似文献   

15.
Misuse of numerous beta-agonist drugs for their growth promoting effects in livestock production requires significant regulatory enforcement activities worldwide. The proof of illegal drug use needed for regulatory action usually requires the high degree of specificity derived from mass spectrometric analysis of suspect tissues and body fluids. In this paper, we describe a multiresidue screening method for confirmation of nine beta-agonist compounds in bovine liver and retina. A wide range of analyte structures was selected in order to demonstrate applicability to other chemically related beta-agonists for which standards are not currently available. The class-specific method, which is based on mixed mode cation exchange/reverse phase solid phase extraction, reverse phase gradient LC separation using a cyanopropyl-silica phase, and tandem mass spectrometry (MS/MS) in the multiple reaction monitoring (MRM) mode, yields high analyte recoveries at the target level of 1 ppb (ng/g). In addition, acquisition of multiple MRM transitions for each analyte permits simultaneous confirmation of beta-agonists at the level of 1 ppb in liver and retina by using intensity ratios between fragment ions and protonated molecules. Estimated values for the limit of quantification (LOQ) for individual beta-agonists were 0.08-0.3 ppb in liver and 0.02-0.5 in retina; the estimated limits of confirmation, using accepted criteria from international regulatory agencies, were 0.25-0.8 ppb in liver and 0.1-1 ppb in retina. This method should be useful in supporting regulatory enforcement programs that monitor beta-agonist misuse.  相似文献   

16.
17.
We demonstrate an approach for global quantitative analysis of protein mixtures using differential stable isotopic labeling of the enzyme-digested peptides combined with microbore liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS). Microbore LC provides higher sample loading, compared to capillary LC, which facilitates the quantification of low abundance proteins in protein mixtures. In this work, microbore LC is combined with MALDI MS via a heated droplet interface. The compatibilities of two global peptide labeling methods (i.e., esterification to carboxylic groups and dimethylation to amine groups of peptides) with this LC-MALDI technique are evaluated. Using a quadrupole-time-of-flight mass spectrometer, MALDI spectra of the peptides in individual sample spots are obtained to determine the abundance ratio among pairs of differential isotopically labeled peptides. MS/MS spectra are subsequently obtained from the peptide pairs showing significant abundance differences to determine the sequences of selected peptides for protein identification. The peptide sequences determined from MS/MS database search are confirmed by using the overlaid fragment ion spectra generated from a pair of differentially labeled peptides. The effectiveness of this microbore LC-MALDI approach is demonstrated in the quantification and identification of peptides from a mixture of standard proteins as well as E. coli whole cell extract of known relative concentrations. It is shown that this approach provides a facile and economical means of comparing relative protein abundances from two proteome samples.  相似文献   

18.
Quaternary ammonium drugs (atracurium, bretylium, edrophonium, ipratropium, mivacurium, neostigmine, pancuronium and rocuronium) and herbicides (difenzoquat, diquat and paraquat) in human whole blood were analysed by LC/MS/MS with positive electrospray ionisation (ESI), following extraction with Bond Elut LRC-CBA cartridges. Internal standards were benzyldimethylphenylammonium chloride monohydrate and ethyl viologen for drug and herbicide analysis, respectively. Ion-pair chromatography used heptafluorobutyric acid (15 mM)-ammonium formate (20 mM) buffer adjusted to pH 3.30 with formic acid and a linear gradient from 5 to 90% methanol run over 18 min. Recoveries ranged from 79.7 to 105.1%, detection limits were between 3.6 and 20.4 ng/ml and the intra- and inter-day precisions were less than 18.6% at a concentration of 10 ng/ml. The method was applied to a case of accidental paraquat poisoning in which the concentration of paraquat in blood was 0.64 mg/l, which is within the range associated with fatal paraquat poisoning.  相似文献   

19.
20.
The promise of mass spectrometry as a tool for probing signal-transduction is predicated on reliable identification of post-translational modifications. Phosphorylations are key mediators of cellular signaling, yet are hard to detect, partly because of unusual fragmentation patterns of phosphopeptides. In addition to being accurate, MS/MS identification software must be robust and efficient to deal with increasingly large spectral data sets. Here, we present a new scoring function for the Inspect software for phosphorylated peptide tandem mass spectra for ion-trap instruments, without the need for manual validation. The scoring function was modeled by learning fragmentation patterns from 7677 validated phosphopeptide spectra. We compare our algorithm against SEQUEST and X!Tandem on testing and training data sets. At a 1% false positive rate, Inspect identified the greatest total number of phosphorylated spectra, 13% more than SEQUEST and 39% more than X!Tandem. Spectra identified by Inspect tended to score better in several spectral quality measures. Furthermore, Inspect runs much faster than either SEQUEST or X!Tandem, making desktop phosphoproteomics feasible. Finally, we used our new models to reanalyze a corpus of 423,000 LTQ spectra acquired for a phosphoproteome analysis of Saccharomyces cerevisiae DNA damage and repair pathways and discovered 43% more phosphopeptides than the previous study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号