首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 211 毫秒
1.
This study analyzed the shells of single-lumen silicone gel breast implants within the general context of device durability in vivo. The investigation included the major types of gel-filled implants that were manufactured in the United States in a 30-year period. The implants analyzed were Cronin seamed (two explants and one control), Silastic 0 and Silastic I (18 explants and seven controls), and Silastic II (22 explants and 43 controls). The biodurability of the explants was investigated with measurements of the mechanical and chemical properties of the various types of silicone gel control and explanted shells, with implantation times ranging from 3 months to 32 years. The shell properties measured for the controls and explants included the stress-strain relationships, tensile strength, elongation, tear resistance, moduli, cross-link density, and amount of extractable material in the shell. In addition, the mechanical properties of shells that had been extracted with hexane were analyzed for both explants and control implants. The silicone gel explants investigated in this study included some of the oldest explants of the various major types that have been tested to date. For assessment of long-term implantation effects, the data obtained in this study were combined with all known data from other institutions on the various major types of gel implants. The study also addressed the failure mechanisms associated with silicone gel breast implants. The results of the study demonstrated that silicone gel implants have remained intact for 32 years in vivo and that degradation of the shell mechanical and chemical properties is not a primary mechanism for silicone gel breast implant failure.  相似文献   

2.
Variability in the properties of silicone gel breast implants.   总被引:4,自引:0,他引:4  
Several generations of silicone gel breast implants have been produced by implant manufacturers. The primary material usually viewed as the base material in the manufacture of implants is polydimethylsiloxane. Polymeric reactions are notorious for their variability and nonuniformity. The elastomer used in different types of implants can have vastly different properties. Furthermore, the material properties associated with a particular type of implant can vary considerably from one lot to the next. Considering the various designs, styles, and manufacturing techniques associated with silicone gel implants, knowledge of the original properties of the implants before implantation is important in determining the effects of aging in vivo. This study was conducted to investigate differences in key mechanical and chemical properties of silicone gel breast implant materials. The two types of implants chosen for analysis were Silastic I and Silastic II control implants. Material property data were determined for both types of controls and significant differences were found in their values. Lot-to-lot variability was also investigated and found to be significant.  相似文献   

3.
Spear SL  Elmaraghy M  Hess C 《Plastic and reconstructive surgery》2000,105(4):1542-52; discussion 1553-4
The earliest silicone breast implants were smooth-surface, silicone rubber devices filled with either silicone gel or saline. Because of persistent problems with capsular contracture, polyurethane-covered silicone implants were developed as an alternative. Particularly in the short run, these alternatives proved highly successful at reducing the incidence of capsular contracture. By 1990, polyurethane-covered implants were rapidly becoming the preferred implant choice of many plastic surgeons, but for legal, regulatory, financial, and safety reasons they were withdrawn from the market by Bristol-Myers in 1991. Meanwhile, during the late 1980s, surface texturing and improved materials became available on other silicone breast implants and expanders. Most studies suggest that textured-surface silicone gel-filled implants, saline-filled implants, and tissue expanders have less frequent capsular contracture than their smooth-surface counterparts.  相似文献   

4.
Little has been published regarding the treatment of patients with long-established capsular contracture after previous submuscular or subglandular breast augmentation. This study reviews 7 years of experience in treating established capsular contracture after augmentation mammaplasty by relocating implants to the "dual-plane" or partly subpectoral position. A retrospective chart review was performed on all patients who were treated for capsular contracture using this technique between 1993 and 1999. Data collected included the date of the original augmentation, the original implant location, date of revision and type of implant used, length of follow-up, outcome, and any ensuing complications. Different surgical techniques were used, depending on whether the prior implant was located in a subglandular or submuscular plane. All patients had revisions such that their implants were relocated to a dual plane, with the superior two thirds or so of the implant located beneath the pectoralis major muscle and the inferior one third located subglandularly. Of 85 patients reviewed, 54 had their original implants in a submuscular position and 31 had their initial augmentation in a subglandular position. Of the 54 patients whose implants were initially submuscular, 23 patients (43 percent) had silicone gel implants, 15 patients (28 percent) had double-lumen implants, and the remaining 16 patients (30 percent) had saline implants. Of the 31 patients whose implants were initially subglandular, 20 patients (65 percent) had silicone gel implants, three patients (10 percent) had double-lumen implants, and the remaining eight patients (26 percent) had saline implants. Fifty-one patients (60 percent) had replacement with saline implants (37 smooth saline, 14 textured saline), whereas 34 (40 percent) had silicone gel implants (seven smooth gel, 27 textured gel). The average time from previous augmentation to revision was 9 years 9 months. The average follow-up time after conversion to the dual-plane position was 11.5 months. Only three of 85 patients required reoperation for complications, all of which involved some degree of implant malposition. Of patients converted to the dual plane, 98 percent were free of capsular contracture and were Baker class I at follow-up, whereas 2 percent were judged as Baker class II. There were no Baker level III or IV contractures at follow-up. The dual-plane method of breast augmentation has proved to be an effective technique for correcting established capsular contracture after previous augmentation mammaplasty. This technique appears to be effective when performed with either silicone or saline-filled implants.  相似文献   

5.
Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untreated ruptures are associated with changes over time in magnetic resonance imaging findings, serologic markers, or self-reported breast symptoms. A baseline magnetic resonance imaging examination was performed in 1999 on 271 women who were randomly chosen from a larger cohort of women having cosmetic breast implants for a median period of 12 years (range, 3 to 25 years). A follow-up magnetic resonance imaging examination was carried out in 2001, excluding women who underwent explantation in the period between the two magnetic resonance imaging examinations (n = 44). On the basis of these examinations, the authors identified 64 women who had at least one ruptured implant at the first magnetic resonance imaging examination and, for comparison, all women who had intact implants at both examinations (n = 98). Magnetic resonance images from the two examinations were compared and changes in rupture configuration were evaluated. Comparisons were also made for self-reported breast symptoms occurring during the study period and for changes in serum values of antinuclear antibodies, rheumatoid factor, and cardiolipin antibodies immunoglobulin G and immunoglobulin M. The majority of the women with implant rupture had no visible magnetic resonance imaging changes of their ruptured implants. For 11 implants (11 percent) in 10 women, the authors observed progression of silicone seepage, either as a conversion from intracapsular into extracapsular rupture (n = 7), as progression of extra-capsular silicone (n = 3), or as increasing herniation of the silicone within the fibrous capsule (n = 1); however, in most cases, these changes were minor. Some changes could be ascribed to trauma, but others seemed spontaneous. There was no increase in levels of autoantibodies during the study period in either study group. Women with untreated implant ruptures reported a significant increase in nonspecific breast changes (odds ratio, 2.1; 95 percent confidence interval, 1.2 to 3.8) compared with women without ruptures. On the basis of this first study of women with untreated silicone breast implant rupture, the authors conclude that implant rupture is a relatively harmless condition, which only rarely progresses and gives rise to notable symptoms. Even so, because of a small risk of silicone spread, the authors suggest that women with implant ruptures be followed clinically, if not operated on. Because implant ruptures often occur asymptomatically, any woman with silicone implants, regardless of rupture status, should be evaluated at regular intervals.  相似文献   

6.
The metatolic fate of silicone gel leaked from an intact or ruptured prosthesis is unknown. In this study, serum was blindly assayed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) for elemental silicon in 72 women with silicone gel breast implants and 55 control women (mean age 48 yr, both groups). Blood was drawn and processed using silicon-free materials. The mean silicon level in controls was 0.13±0.07 mg/L (range 0.06–0.35 mg/L), whereas in implant patients, the mean was significantly higher at 0.28±0.22 mg/L (range 0.06–0.87 mg/L) (P<0.01, Student'st-test with correction for unequal variances). Using the mean of the control group +2 SD as a cutoff for normal range (0.27 mg/L), 25/72 (34.7%) implant patients exceeded this value, compared with 2/55 (3.6%) controls. There was no significant correlation between past rupture of one or both implants, current rupture at the time of the blood draw, or the number of years with implants and silicon levels. The results suggest that serum silicon levels are elevated in many women with silicone gel breast implants. The chemical species involved and kinetics of this elevation remain to be determined.  相似文献   

7.
Calcification properties of saline-filled breast implants   总被引:1,自引:0,他引:1  
Three patients requested explantation of their saline-filled breast implants. Bilateral calcification had occurred in all six implants. Four of the implants were manufactured by McGhan Corporation (Santa Barbara, Calif.), and two, by the Simaplast Company (Toulon, France). All implants had been inserted in the subglandular plane and had been in place for 7 to 23 years. At the time of explantation, patients were 32, 34, and 44 years old. Calcification on the surface of the implants and capsules was analyzed. Implant surface calcification was clinically evident on all six implants, appearing as ivory-colored, tenaciously adherent deposits, only on the anterior surface of the implant. Capsular calcification, which was observed only microscopically, was characterized by poorly organized, irregularly shaped, calcified agglomerates; this calcification also occurred only on the anterior surface of the capsule, adjacent to the area of calcification on the implant. Ultrastructural analysis of scrapings from the implant surface showed large, electron-dense aggregates of crystals, with individual crystals measuring approximately 40 x 10 x 10 nm. In contrast, capsular calcification was characterized by two patterns of deposition, spherulitic aggregates of needle-shaped crystals and areas of metaplastic bone. The individual crystals were approximately 40 x 10 x 10 nm. Energy-dispersive x-ray spectroscopy of specimens from the areas of calcification on the implant and capsule surfaces demonstrated calcium and phosphorus. Electron diffraction of crystals from the implant and capsule surfaces demonstrated the D-spacings characteristic of calcium apatite. There were many differences between the calcification properties of these six saline implants and those of silicone gel implants. For example, mineralization has not been observed on the surface of gel implants, but in these saline implants it occurred primarily on the implant surface. Also, capsular calcification has been observed clinically in gel implants across the surface of the capsule (except at the site of attachment of a Dacron patch), but in this study it was observed only microscopically and was located on the anterior surface of the capsule, adjacent to the area of calcification on the implant. In addition, crystals 100 times larger than those observed on the six saline implant capsules have been observed on the surface of gel implant capsules. A model is presented to explain the mechanism of calcification associated with breast implants and to explain the observed differences between saline-filled and gel-filled implants.  相似文献   

8.
We present evidence of the following. 1. Modern silicone bag-gel breast implants leak silicone gel through the bag. 2. The amount of silicone leaked by an intact implant varies from one implant to another, and is not constant for any type or brand. 3. The leaked silicone, together with fibrous thickening and various degrees of inflammation will be found in capsules surrounding the implants if extensive biopsies are taken and many sections are examined.  相似文献   

9.
Long-term use of polyurethane breast prostheses: a 14-year experience   总被引:1,自引:0,他引:1  
I have used polyurethane prostheses for the past 14 years, implanting 220 implants into 130 patients who desired breast reconstruction after subcutaneous mastectomy or cancer ablation or simply breast augmentation. I theorize that a polyurethane-covered implant resists contracture, retaining its compressibility because the fibroblasts proliferate into the polyurethane in many different directions. When the fibrils contract, the forces of contracture counterbalance one another, resisting contracture. However, when smooth prostheses are implanted, fibrils are directed in a circular fashion around the implant and naturally contract, leading to firmer breasts. There were 115 prostheses inserted following subcutaneous mastectomy, and 22 percent developed contracted capsules. Seven implants became exposed because of skin necroses; one was removed because of a Staphylococcus infection; and two patients developed a combination of polyurethane and silicone granulomas. These developed only with the earlier implant, where there was shedding of the polyurethane sponge layer and silicone bled from the low-viscosity silicone used in the earlier implants. No granulomas were noted with the currently used Surgitek Replicon implant. Eighty-five breasts were reconstructed after cancer ablation with polyurethane implants, and the contracture rate was 2.3 percent. Other complications were minimal. A smaller group of patients had augmentation mammaplasty, and 20 prostheses were placed in 10 patients. A 15 percent contracture rate was noted in this group. In this study, 82 percent of patients were followed for up to 14 years. Capsular contractures occurred in 30 implants between 1 and 11 years, for an average recurrence at 6.3 years. The overall contracture rate was 13 percent. Other complications were minimal. All implants were placed subcutaneously or subglandularly, and all were drained.  相似文献   

10.
Current implants for breast augmentation containing silicone gel, saline, or both can totally obscure mammographic detection of microcalcifications and soft-tissue masses. To investigate the possibility of developing a more radiolucent implant, radiographs were obtained of silicone shells that contained silicone gel, saline, silicone gel and saline, polyurethane-covered silicone gel, gelatin, sunflower oil, and peanut oil. All radiographs were obtained using a Siemens Mammomat by placing the implant over an American College of Radiology mammography phantom. Results were measured by the ability to visualize or resolve the artifacts in the mammography phantom. The silicone shell alone minimally altered artifact resolution. Silicone shells filled with silicone gel, silicone gel and saline, saline alone, polyurethane-covered silicone gel, and gelatin were equal in radiodensity and completely obscured all phantom artifacts. Silicone shells filled with peanut oil and sunflower oil had equal radiodensity and allowed visualization of large microcalcifications and some soft-tissue masses. Current implants used for augmentation mammaplasty can totally obscure mammographic detection of microcalcifications and soft-tissue masses. A more radiolucent breast implant is possible, and further research is needed to define the best filler material and test its biocompatibility.  相似文献   

11.
Although textured silicone breast implants have been shown to reduce the incidence of capsular contracture, there is little evidence if this effect is maintained in the long term. It has been 10 years since the double-blind randomized trial in which 53 patients received either Mentor smooth (26) or textured silicone gel implants (27). Of the 14 patients who were not known to have developed a contracture in the smooth group, 11 were reviewed. Three had bilateral contractures. In the textured group, 18 of the 24 patients not known to have contractures were reviewed. None had developed contractures. At 10 years, the incidence of capsular contracture was 65 percent of patients with smooth implants (an increase of 6 percent on the 3-year results) and 11 percent for the textured implant patients (no change on the 3-year results). A database containing the details of 1100 patients reinforces these results by examining the differences in contracture rates of textured, smooth, and polyurethane-coated implants. The effect of submuscular placement on reducing contracture rates regardless of texturing is discussed, as is the apparent increase in capsular contracture in patients who smoke.  相似文献   

12.
Current implants for breast augmentation containing silicone gel, saline, or both are radiopaque on mammographic examination and can totally obscure microcalcifications and soft-tissue masses. The effect of these implants on the detection of early breast cancers in patients who have undergone augmentation mammaplasty remains unproven and controversial. Implants filled with medium-chain triglycerides (peanut oil) are radiolucent on mammographic examination and allow visualization of both soft-tissue masses and microcalcifications. To investigate the biocompatibility of radiolucent implants, 10 cc of sterile, nonpyrogenic peanut oil was injected subcutaneously into rats using silicone gel as a control. Twenty-one rabbits had two 125-cc silicone shell implants inserted on either side of the chest wall. The right-sided shell was filled with 125 cc of sterile saline, and the left-sided shell was filled with 125 cc of sterile, nonpyrogenic peanut oil. Results were determined by both histologic and radiographic examination. Rats injected with peanut oil equivalent to 7 percent of their body weight rapidly absorbed the freely injected oil without detriment. Histologic examination of the lungs, liver, kidneys, and tissues adjacent to the injection sites demonstrated no abnormalities. There was no evidence of allergic, toxic, inflammatory, or neoplastic response. Eighteen of 21 rabbits survived more than 3 months. Radiographs showed the oil-filled implants to be radiolucent, whereas the saline-filled controls obscured the surrounding soft and bony tissues. Histologic examination demonstrated a fibrous capsule surrounding both types of implants. Histologic examination of the lungs, liver, and kidneys showed no significant abnormalities. These and previous studies have shown peanut oil to be biocompatible when freely injected either intramuscularly or subcutaneously. This study demonstrates that a radiolucent, peanut oil-filled implant is biocompatible in animals and that further long-term studies for its use in humans are merited.  相似文献   

13.
Zambacos GJ  Nguyen D  Morris RJ 《Plastic and reconstructive surgery》2004,114(3):706-10; discussion 711-2
Irrigation of breast implants and breast implant pockets with various solutions, including povidone iodine, has been a common practice among plastic surgeons for many years. Recent reports of potential weakening of silicone tubing have led the Food and Drug Administration to pronounce any contact of povidone iodine with breast implants a contraindication. An in vitro experimental study was undertaken to assess the effect of povidone iodine on the physical properties of silicone breast implant shells. Identical specimens were obtained from the shells of silicone breast implants according to published standards. The specimens were randomly assigned to eight groups of five and incubated in various solutions of decreasing concentration of povidone iodine (10% to 0.01%), and a control group (0.9% saline) was used. The containers were stored in a warming cabinet at 37 degrees C for 4 weeks. Testing of the specimens for tensile strength following 4 weeks of incubation showed no significant difference among any of the groups, including the control group. In addition, no correlation was shown between the concentration of the solution used and the tensile strength of the specimens.  相似文献   

14.
During the U.S. Food and Drug Administration's advisory panel hearings to evaluate the premarket approval for conventional silicone gel implants on October 14 and 15, 2003, panel members and patient advocate representatives focused on four specific areas of concern: reoperation rates in primary breast augmentation; levels, depth, and methods of patient education and informed consent; modes, frequency, and management of silicone gel implant device failures, including management of "silent" ruptures; and methods of monitoring and managing symptoms or symptom complexes that may or may not be associated with connective tissue disease or other undefined symptom complexes. These concerns, with a reported 20 percent reoperation rate for primary augmentation within just 3 years, and a lack of concise, definitive management protocols addressing these areas of concern may have contributed to the Food and Drug Administration's rejection of the premarket approval, despite the panel's recommendation for approval. This article presents decision and management algorithms that have been used successfully for 7 years in a busy breast augmentation practice (Tebbetts and Tebbetts). The algorithms have been further expanded and refined by a group of surgeons with diverse experiences and expertise to address the following clinical situations that coincide with concerns expressed by patients and the Food and Drug Administration: implant size exchange, grade III to IV capsular contracture, infection, stretch deformities (implant bottoming or displacement), silent rupture of gel implants, and undefined symptom complexes (connective tissue disease or other). In one practice (Tebbetts and Tebbetts) that uses the TEPID system (tissue characteristics of the envelope, parenchyma, and implant and the dimensions and fill distribution dynamics of the implant), implant selection is based on quantified patient tissue characteristics, pocket selection is based on quantified soft-tissue coverage, and anatomic saline implants have fill volumes that are designed to minimize shell collapse and fold fatigue; in this practice, the algorithms contributed to a 3 percent overall reoperation rate in 1662 reported cases with up to 7 years of follow-up, compared with a 20 percent reoperation rate at 3 years in the 2003 premarket approval study.  相似文献   

15.
Hidalgo DA 《Plastic and reconstructive surgery》2000,105(6):2202-16; discussion 2217-8
A retrospective study of 220 patients was performed to review surgical design in breast augmentation. Three specific issues were studied: incision site, implant variables, and pocket plane selection. The influence of these three factors on aesthetic results in both primary and secondary cases was the focus of the analysis. No attempt was made to address long-term issues such as capsular contracture or saline implant deflation rates. In 77 primary augmentation patients and 80 unilateral augmentations for symmetry in breast reconstruction, there were the following untoward results: 11 revisions for unilateral malposition, change to a different implant shape, or change to a larger implant size; four deflations of saline implants requiring replacement; and four conversions of saline to silicone gel implants. In 63 secondary cases, there were two hematomas and two infections requiring implant removal and subsequent replacement. Operative technique in breast augmentation is described, as are recommendations for each of the options associated with the three variables studied.  相似文献   

16.
Metaplasia is a reversible phenomenon that usually occurs in response to chronic irritation and/or inflammation. It allows for the substitution of fragile cells with those that are better able to survive under various circumstances. Our study aims to describe the histology of one unusual type of metaplasia results in the formation of a synovial-like membrane typical of joints inside a female patient’s breasts around silicone implants. We analyzed samples from 22 female patients, who underwent delayed-staged breast reconstructions. Attention was paid especially to tissue that was in direct contact with the silicone expander and that was under permanent pressure and friction between the implant and the surrounding tissue. Biopsies of explanted periprosthetic capsules were processed for examination by light microscopy. Immunohistochemical staining (ten different primary antibodies) was performed to examine a variety of cell-specific antigens. At the interface between the tissue capsule and the silicone breast expander, we typically observed a 50–200-μm cellular lining. Thanks to the high cellular density, this cellular layer resembled epithelium. However, there was no basement membrane, and cells were negative for cytokeratin. The cells forming the superficial layer were strongly positive for vimentin and podoplanin and weakly positive for the S100 protein. These cells did not express desmin or smooth muscle actin. Within the most superficial layer (synovial intima), we distinguished two types of cells: phagocytic (CD68-positive) and fibroblast-like synovial cells. We conclude that the cellular lining surrounding silicone breast implants looks like a true synovial membrane resembling a fibrous form of synovium.  相似文献   

17.
Silicone-gel breast implants have been associated with a myriad of autoimmune and connective tissue disorders by anecdotal reports and small observational series. To date, no prospective epidemiologic studies have been done to substantiate these observations, but an increasing body of literature is being developed and older studies are being recognized that point to immunotoxic or inflammatory effects of these breast implant components. The development of disease due to implants would depend on the interaction of genetic host factors so that only a few patients would potentially be at risk. Based on the example of other chemically mediated disorders, such as scleroderma in association with silica exposure, latency periods of more than 30 years before disease develops may be possible. Herein we review studies on silicone and immunity.  相似文献   

18.
Radiolucent prosthetic gel.   总被引:2,自引:0,他引:2  
The successful use of silicone breast implants is complicated by their interference with mammography. We have evaluated clinically available implant filling materials and found that a new Bio-Oncotic gel approximates the radiolucency of normal breast tissue. Silicone implants completely obscure areas of the breast in mammography. Recently proposed as a filler material, peanut oil is significantly more radiolucent than normal tissue. Physiologic saline solution compares favorably as a tissue-density-simulating substance. However, saline's lack of lubricating properties results in leakage, making it less than optimal. Bio-Oncotic gel is biologically compatible. We conclude that this gel is the most appropriate filler for breast prostheses. Clinical studies are indicated.  相似文献   

19.
Epidemiologic evidence does not support an association between silicone breast implants and connective tissue or other rheumatic diseases. However, a recent study has suggested that women with ruptured implants may be at increased risk of developing fibromyalgia. An analysis of adverse health outcomes according to breast implant rupture status was conducted in 238 unselected Danish women with cosmetic silicone breast implants. Ninety-two of the women had definite implant rupture, and 146 had intact implants as determined by magnetic resonance imaging. Before undergoing imaging, the women provided blood samples and completed a self-administered questionnaire. Women with ruptured implants overall, and the subgroup with extracapsular ruptures (n = 23), were compared with women with intact implants regarding a number of self-reported diseases and symptoms and the presence of specific autoantibodies, such as antinuclear antibodies, rheumatoid factor, and cardiolipin immunoglobulin G and M antibodies. Overall, there were no differences in the occurrence of self-reported diseases or symptoms or in the presence of autoantibodies between women with intact implants and women with ruptured implants, including extracapsular rupture. The only exception was capsular contracture, which was reported six times more frequently by women with extracapsular ruptures than by women with intact implants (OR, 6.3; 95 percent CI, 1.7 to 23.5). In conclusion, this study of unselected women with silicone breast implants could establish no association between silicone implant rupture and specific diseases or symptoms related to connective tissue disease or other rheumatic conditions, except for an excess of capsular contracture among women with extracapsular rupture.  相似文献   

20.
An inflatable breast implant having a detachable filling reservoir is described. Once in position, the implant can be filled under controlled conditions postoperatively. The implant functions either as a tissue expander or as a delayed-filling implant in the initial stages of the procedure. Once the desired breast size is achieved, the reservoir is removed, leaving the filled implant in position. This implant has been used successfully in various types of breast reconstructive procedures, including both primary and secondary reconstruction following modified mastectomy, immediate reconstruction following subcutaneous mastectomy, secondary reconstruction following radical mastectomy combined with the latissimus dorsi flap, and following the removal of silicone gel implants with associated capsular contracture. A total of 23 patients, representing 34 breasts, are reported on. The results have been encouraging over a period of 20 months of follow-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏