首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
The fusion of individual influenza virions with a planar phospholipid membrane was detected by fluorescence video microscopy. Virion envelopes were loaded with the lipophilic fluorescent marker octadecylrhodamine B (R18) to a density at which the fluorescence of the probe was self-quenched. Labeled virions were ejected toward the planar membrane from a micropipette in a custom-built video fluorescence microscope. Once a virion fused with the planar membrane, the marker was free to diffuse, and its fluorescence became dequenched, producing a flash of light. This flash was detected as a transient spot of light which increased and then diminished in brightness. The diffusion constants calculated from the brightness profiles for the flashes are consistent with fusion of virus to the membrane with consequent free diffusion of probe within the planar membrane. Under conditions known to be fusigenic for influenza virus (low pH and 37 degrees C), flashes appeared at a high rate and the planar membrane quickly became fluorescent. To further establish that these flashes were due to fusion, we showed that red blood cells, which normally do not attach to planar membranes, were able to bind to membranes that had been exposed to virus under fusigenic conditions. The amount of binding correlated with the amount of flashing. This indicates that flashes signaled the reconstitution of the hemagglutinin glycoprotein (HA) of influenza virus, a well-known erythrocyte receptor, into the planar membrane, as would be expected in a fusion process. The flash rate on ganglioside-containing asolectin membranes increased as the pH was lowered. This is also consistent with the known fusion behavior of influenza virus with cell membranes and with phospholipid vesicles. We conclude that the flashes result from the fusion of individual virions to the planar membrane.  相似文献   

2.
Video fluorescence microscopy was used to study adsorption and fusion of unilamellar phospholipid vesicles to solvent-free planar bilayer membranes. Large unilamellar vesicles (2-10 microns diam) were loaded with 200 mM of the membrane-impermeant fluorescent dye calcein. Vesicles were ejected from a pipette brought to within 10 microns of the planar membrane, thereby minimizing background fluorescence and diffusion times through the unstirred layer. Vesicle binding to the planar membrane reached a maximum at 20 mM calcium. The vesicles fused when they were osmotically swollen by dissipating a KCl gradient across the vesicular membrane with the channel-forming antibiotic nystatin or, alternatively, by making the cis compartment hyperosmotic. Osmotically induced ruptures appeared as bright flashes of light that lasted several video fields (each 1/60 s). Flashes of light, and therefore swelling, occurred only when channels were present in the vesicular membrane. The flashes were observed when nystatin was added to the cis compartment but not when added to the trans. This demonstrates that the vesicular and planar membranes remain individual bilayers in the region of contact, rather than melding into a single bilayer. Measurements of flash duration in the presence of cobalt (a quencher of calcein fluorescence) were used to determine the side of the planar membrane to which dye was released. In the presence of 20 mM calcium, 50% of the vesicle ruptures were found to result in fusion with the planar membrane. In 100 mM calcium, nearly 70% of the vesicle ruptures resulted in fusion. The methods of this study can be used to increase significantly the efficiency of reconstitution of channels into planar membranes by fusion techniques.  相似文献   

3.
In vitro motility assays, in which fluorescently labeled actin filaments are propelled by myosin molecules adhered to a glass coverslip, require that actin filament velocity be determined. We have developed a computer-assisted filament tracking system that reduced the analysis time, minimized investigator bias, and provided greater accuracy in locating actin filaments in video images. The tracking routine successfully tracked filaments under experimental conditions where filament density, size, and extent of photobleaching varied dramatically. Videotaped images of actin filament motility were digitized and processed to enhance filament image contrast relative to background. Once processed, filament images were cross correlated between frames and a filament path was determined. The changes in filament centroid or center position between video frames were then used to calculate filament velocity. The tracking routine performance was evaluated and the sources of noise that contributed to errors in velocity were identified and quantified. Errors originated in algorithms for filament centroid determination and in the choice of sampling interval between video frames. With knowledge of these error sources, the investigator can maximize the accuracy of the velocity calculation through access to user-definable computer program parameters.  相似文献   

4.
The fusion of sea urchin egg secretory vesicles to planar phospholipid bilayer membranes was studied by differential interference contrast (DIC) and fluorescent microscopy, in combination with electrical recordings of membrane conductance. A strong binding of vesicles to protein-free planar membranes was observed in the absence of calcium. Calcium-induced fusion of vesicles was detected using two independent assays: loss of the contents of individual vesicles visible by DIC microscopy: and vesicle content discharge across the planar membrane detected by an increase in the fluorescence of a dye. In both cases, no increase in the membrane conductance was observed unless vesicles were incubated with either Amphotericin B or digitonin prior to applying them to the planar membrane, an indication that native vesicles are devoid of open channels. Pre-incubation of vesicles with n-ethylmaleimide (NEM) abolished calcium-induced fusion. Fusion was also detected when vesicles were osmotically swollen to the point of lysis. In contrast, no fusion of vesicles to planar bilayers was seen when vesicles on plasma membrane (native cortices) were applied to a phospholipid membrane, despite good binding of vesicles to the planar membrane and fusion of vesicles to plasma membrane. It is suggested that cortical vesicles (CVs) have sufficient calcium-sensitive proteins for fusion to lipid membranes, but in native cortices granular fusion sites are oriented toward the plasma membrane. Removal of vesicles from the plasma membrane may allow fusion sites on vesicles access to new membranes.  相似文献   

5.
The fusion of sea urchin egg secretory vesicles to planar phospholipid bilayer membranes was studied by differential interference contrast (DIC) and fluorescent microscopy, in combination with electrical recordings of membrane conductance. A strong binding of vesicles to protein-free planar membranes was observed in the absence of calcium. Calciuminduced fusion of vesicles was detected using two independent assays: loss of the contents of individual vesicles visible by DIC microscopy; and vesicle content discharge across the planar membrane detected by an increase in the fluorescence of a dye. In both cases, no increase in the membrane conductance was observed unless vesicles were incubated with either Amphotericin B or digitonin prior to applying them to the planar membrane, an indication that native vesicles are devoid of open channels. Pre-incubation of vesicles with n-ethylmaleimide (NEM) abolished calcium-induced fusion. Fusion was also detected when vesicles were osmotically swollen to the point of lysis. In contrast, no fusion of vesicles to planar bilayers was seen when vesicles on plasma membrane (native cortices) were applied to a phospholipid membrane, despite good binding of vesicles to the planar membrane and fusion of vesicles to plasma membrane. It is suggested that cortical vesicles (CVs) have sufficient calcium-sensitive proteins for fusion to lipid membranes, but in native cortices granular fusion sites are oriented toward the plasma membrane. Removal of vesicles from the plasma membrane may allow fusion sites on vesicles access to new membranes.  相似文献   

6.
Multilamellar phospholipid vesicles are introduced into the cis compartment on one side of a planar phospholipid bilayer membrane. The vesicles contain a water-soluble fluorescent dye trapped in the aqueous phases between the lamellae. If a vesicle containing n lamellae fuses with a planar membrane, an n-1 lamellar vesicle should be discharged into the opposite trans compartment, where it would appear as a discernible fluorescent particle. Thus, fusion events can be assayed by counting the number of fluorescent particles appearing in the trans compartment. In the absence of divalent cation, fusion does not occur, even after vesicles have been in the cis compartment for 40 min. When CaCl2 is introduced into the cis compartment to a concentration of greater than or equal to 20 mM, fusion occurs within the next 20 min; it generally ceases thereafter because of vesicle aggregation in the cis compartment. With approximately 3 x 10(8) vesicles/cm3 in the cis compartment, about 25-50 fusion events occur following CaCl2 addition. The discharge of vesicular contents across the planar membrane is the most convincing evidence of vesicle-membrane fusion and serves as a model for that ubiquitous biological phenomenon--exocytosis.  相似文献   

7.
Single particle tracking has seen numerous applications in biophysics, ranging from the diffusion of proteins in cell membranes to the movement of molecular motors. A plethora of computer algorithms have been developed to monitor the sub-pixel displacement of fluorescent objects between successive video frames, and some have been claimed to have "nanometer" resolution. To date, there has been no rigorous comparison of these algorithms under realistic conditions. In this paper, we quantitatively compare specific implementations of four commonly used tracking algorithms: cross-correlation, sum-absolute difference, centroid, and direct Gaussian fit. Images of fluorescent objects ranging in size from point sources to 5 microm were computer generated with known sub-pixel displacements. Realistic noise was added and the above four algorithms were compared for accuracy and precision. We found that cross-correlation is the most accurate algorithm for large particles. However, for point sources, direct Gaussian fit to the intensity distribution is the superior algorithm in terms of both accuracy and precision, and is the most robust at low signal-to-noise. Most significantly, all four algorithms fail as the signal-to-noise ratio approaches 4. We judge direct Gaussian fit to be the best algorithm when tracking single fluorophores, where the signal-to-noise is frequently near 4.  相似文献   

8.
Real-time multi-wavelength fluorescence imaging of living cells   总被引:4,自引:0,他引:4  
S J Morris 《BioTechniques》1990,8(3):296-308
We describe a new real-time fluorescence video microscope design for capturing intensified images of cells containing dual wavelength "ratio" dyes or multiple dyes. The microscope will perform real-time capture of two separate fluorescence emission images simultaneously, improving the time resolution of spatial distribution of fluorescence to video frame rates (30 frames/s or faster). Each emission wavelength is imaged simultaneously by one of two cameras, then digitized, background corrected and appropriately combined at standard video frame rates to be stored at high resolution on tape or digital video disk for further off-line analysis. Use of low noise, high sensitivity image intensifiers, coupled to CCD cameras produce stable, high contrast images using ultra low light levels with little persistence or bloom. The design has no moving parts in its optical train, which overcomes a number of technical difficulties encountered in the present filter wheel designs for multiple imaging. Coupled to compatible image processing software utilizing PC-AT computers, the new design can be built for a significantly lower cost than many presently available commercial machines. The system is ideal for ratio imaging applications; the software can calculate the ratio of fluorescence intensities pixel by pixel and provide the information to generate false-color images of the intensity data as well as other calculations based on the two images. Thus, it provides a powerful, inexpensive tool for studying the real-time kinetics of changes in living cells. Examples are presented for the kinetics of rapidly changing intracellular calcium detected by the calcium indicator probe indo-1 and the redistribution kinetics of multiple vital dyes placed in cells undergoing cell fusion.  相似文献   

9.
The accurate measurement of bacterial and protistan cell biomass is necessary for understanding their population and trophic dynamics in nature. Direct measurement of fluorescently stained cells is often the method of choice. The tedium of making such measurements visually on the large numbers of cells required has prompted the use of automatic image analysis for this purpose. Accurate measurements by image analysis require an accurate, reliable method of segmenting the image, that is, distinguishing the brightly fluorescing cells from a dark background. This is commonly done by visually choosing a threshold intensity value which most closely coincides with the outline of the cells as perceived by the operator. Ideally, an automated method based on the cell image characteristics should be used. Since the optical nature of edges in images of light-emitting, microscopic fluorescent objects is different from that of images generated by transmitted or reflected light, it seemed that automatic segmentation of such images may require special considerations. We tested nine automated threshold selection methods using standard fluorescent microspheres ranging in size and fluorescence intensity and fluorochrome-stained samples of cells from cultures of cyanobacteria, flagellates, and ciliates. The methods included several variations based on the maximum intensity gradient of the sphere profile (first derivative), the minimum in the second derivative of the sphere profile, the minimum of the image histogram, and the midpoint intensity. Our results indicated that thresholds determined visually and by first-derivative methods tended to overestimate the threshold, causing an underestimation of microsphere size. The method based on the minimum of the second derivative of the profile yielded the most accurate area estimates for spheres of different sizes and brightnesses and for four of the five cell types tested. A simple model of the optical properties of fluorescing objects and the video acquisition system is described which explains how the second derivative best approximates the position of the edge.  相似文献   

10.
The accurate measurement of bacterial and protistan cell biomass is necessary for understanding their population and trophic dynamics in nature. Direct measurement of fluorescently stained cells is often the method of choice. The tedium of making such measurements visually on the large numbers of cells required has prompted the use of automatic image analysis for this purpose. Accurate measurements by image analysis require an accurate, reliable method of segmenting the image, that is, distinguishing the brightly fluorescing cells from a dark background. This is commonly done by visually choosing a threshold intensity value which most closely coincides with the outline of the cells as perceived by the operator. Ideally, an automated method based on the cell image characteristics should be used. Since the optical nature of edges in images of light-emitting, microscopic fluorescent objects is different from that of images generated by transmitted or reflected light, it seemed that automatic segmentation of such images may require special considerations. We tested nine automated threshold selection methods using standard fluorescent microspheres ranging in size and fluorescence intensity and fluorochrome-stained samples of cells from cultures of cyanobacteria, flagellates, and ciliates. The methods included several variations based on the maximum intensity gradient of the sphere profile (first derivative), the minimum in the second derivative of the sphere profile, the minimum of the image histogram, and the midpoint intensity. Our results indicated that thresholds determined visually and by first-derivative methods tended to overestimate the threshold, causing an underestimation of microsphere size. The method based on the minimum of the second derivative of the profile yielded the most accurate area estimates for spheres of different sizes and brightnesses and for four of the five cell types tested. A simple model of the optical properties of fluorescing objects and the video acquisition system is described which explains how the second derivative best approximates the position of the edge.  相似文献   

11.
Synaptic transmission is achieved by exocytosis of small, synaptic vesicles containing neurotransmitters across the plasma membrane. Here, we use a DNA-tethered freestanding bilayer as a target architecture that allows observation of content transfer of individual vesicles across the tethered planar bilayer. Tethering and fusion are mediated by hybridization of complementary DNA-lipid conjugates inserted into the two membranes, and content transfer is monitored by the dequenching of an aqueous content dye. By analyzing the diffusion profile of the aqueous dye after vesicle fusion, we are able to distinguish content transfer across the tethered bilayer patch from vesicle leakage above the patch.  相似文献   

12.
Fusion of multilamellar phospholipid vesicles with planar phospholipid bilayer membranes was monitored by the rate of appearance in the planar membrane of an intrinsic membrane protein present in the vesicle membranes. An essential requirement for fusion is an osmotic gradient across the planar membrane, with the cis side (the side containing the vesicles) hyperosmotic to the opposite (trans) side; for substantial fusion rates, divalent cation must also be present on the cis side. Thus, the low fusion rates obtained with 100 mM excess glucose in the cis compartment are enhanced orders of magnitude by the addition of 5-10 mM CaCl2 to the cis compartment. Conversely, the rapid fusion rates induced by 40 mM CaCl2 in the cis compartment are completely suppressed when the osmotic gradient (created by the 40 mM CaCl2) is abolished by addition of an equivalent amount of either CaCl2, NaCl, urea, or glucose to the trans compartment. We propose that fusion occurs by the osmotic swelling of vesicles in contact with the planar membrane, with subsequent rupture of the vesicular and planar membranes in the region of contact. Divalent cations catalyze this process by increasing the frequency and duration of vesicle-planar membrane contact. We argue that essentially this same osmotic mechanism drives biological fusion processes, such as exocytosis. Our fusion procedure provides a general method for incorporating and reconstituting transport proteins into planar phospholipid bilayer membranes.  相似文献   

13.
Fusion of phospholipid vesicles with planar bilayer membranes occurs provided there is an intermembrane contact, which can be mediated by phospholipid-binding proteins, even in the absence of calcium. The firm attachment phase is then followed by the osmotically-driven fusion. These results show that hydrophobic proteins (not necessarily Ca2+-binding proteins) may enhance fusion by promoting contact of membranes. Such proteins may operate synergistically with Ca2+ to reduce the threshold concentration of Ca2+ needed for fusion of biological membranes. Protein-mediated intermembrane contact resulting in fusion may play a crucial role in the regulation and catalysis of biological fusion events.  相似文献   

14.
BACKGROUND: We developed the CellTracks cell analysis system that, similar to flow cytometry, yields multiparameter information by which the cells can be differentiated. We describe the implementation of a laser scanning imaging method in the system. Image analysis of the cells improves the specificity of cell classification, especially in cases where the particular cells are found relatively infrequently and one has to discriminate between artifacts and real events. METHODS: Fluorescent images of immunomagnetically labeled and aligned cells are obtained by passing the cells through a laser focus. The laser focus is smaller than the objects and subsequent frames captured by a regular surveillance CCD camera with a frame grabber board represent different parts of the cells. Complete images of the cells are constructed by shifting each image with respect to each other and adding individual pixel values. RESULTS: The power of combining a fluorescent image with multiparametric data is demonstrated by imaging fluorescent and magnetically labeled beads and cells. The image gives additional information about the dye distribution across the objects. Changes in dye distribution as a function of time were observed in leukocytes labeled with the red fluorescent label, Oxazine750, which are imaged at different time intervals. CONCLUSIONS: An imaging technique implemented in the CellTracks system provides high-resolution fluorescent images of events previously identified by the system. The images of the fluorescent cells enhance the ability to classify rare events.  相似文献   

15.
Voltage was investigated as a factor in the fusion of virions. Virions, pseudotyped with a class II, SFV E1 or VEEV E, or a class III protein, VSV G, were prepared with GFP within the core and a fluorescent lipid. This allowed both hemifusion and fusion to be monitored. Voltage clamping the target cell showed that fusion is promoted by a negative potential and hindered by a positive potential. Hemifusion occurred independent of polarity. Lipid dye movement, in the absence of content mixing, ceased before complete transfer for positive potentials, indicating that reversion of hemifused membranes into two distinct membranes is responsible for voltage dependence and inhibition of fusion. Content mixing quickly followed lipid dye transfer for a negative potential, providing a direct demonstration that hemifusion induced by class II and class III viral proteins is a functional intermediate of fusion. In the hemifused state, virions that fused exhibited slower lipid transfer than did nonfusing virions. All viruses with class II or III fusion proteins may utilize voltage to achieve infection.  相似文献   

16.
Algorithms are presented for effective suppression of the quantum noise artifact that is inherent to three-dimensional confocal fluorescence microscopy images of extended spatial objects such as neurons. The specific advances embodied in these algorithms are as follows: (i) they incorporate an automatic and pattern-constrained three-dimensional segmentation of the image field, and use it to limit any smoothing to the interiors of specified image regions and hence avoid the blurring that is inevitably associated with conventional noise removal algorithms; (ii) they are ‘unsupervised’ in the sense that they automatically estimate and adapt to the unknown spatially and temporally varying noise level in the microscopy data. Fast computation is achieved by parallel computation methods, rather than by algorithmic or modelling compromises.The quantum noise artifact is modelled using a mixture of spatially non-homogeneous Poisson point processes. The intensity of each component process is constrained to lie in specific intervals. A set of segmentation and edge-site variables are used to determine the intensity of the mixture process. Using this model, the noise-removal process is formulated as the joint optimal estimation of the segmentation labels, edge-sites and intensity of the mixture Poisson point process, subject to a combination of stochastic priors and syntactic pattern constraints. The computations proceed iteratively, starting from a set of approximate user-supplied, or default initial guesses of the underlying random process parameters. An Expectation Maximization algorithm is used to obtain a more precise characterization of these parameters, that are then input to a joint estimation algorithm.Stereoscopic renderings of processed three-dimensional images of murine hippocampal neurons are presented to demonstrate the effectiveness of the method. The processed images exhibit increased contrast and significant smoothing and reduction of the background intensity while avoiding any blurring of the foreground neuronal structures.  相似文献   

17.
High-performance confocal system for microscopic or endoscopic applications   总被引:1,自引:0,他引:1  
We designed a high-performance confocal system that can be easily adapted to an existing light microscope or coupled with an endoscope for remote imaging. The system employs spatially and temporally patterned illumination produced by one of several mechanisms, including a micromirror array video projection device driven by a computer video source or a microlens array scanned by a piezo actuator in the microscope illumination path. A series of subsampled "component" video images are acquired from a solid-state video camera. Confocal images are digitally reconstructed using "virtual pinhole" synthetic aperture techniques applied to the collection of component images. Unlike conventional confocal techniques that raster scan a single detector and illumination point, our system samples multiple locations in parallel, with particular advantages for monitoring fast dynamic processes. We compared methods of patterned illumination and confocal image reconstruction by characterizing the point spread function, contrast, and intensity of imaged objects. Sample 3D reconstructions include a diatom and a Golgi-stained nerve cell collected in transmission.  相似文献   

18.
A novel method was developed for the direct examination of pairwise encounters between positively and negatively charged phospholipid bilayer vesicles. Giant bilayer vesicles (unilamellar, 4–20 μm in diameter) prepared from 1,2-dioleoyl-sn-glycero-3-ethylphosphocholine, a new cationic phospholipid derivative, were electrophoretically maneuvered into contact with individual anionic phospholipid vesicles. Fluorescence video microscopy revealed that such vesicles commonly underwent fusion within milliseconds (1 video field) after contact, without leakage. Fusion occurred at constant volume and, since flaccid vesicles were rare, the excess membrane was not available after fusion. Hemifusion (the outer monolayers of each vesicle fused while the inner monolayers remained intact) was inferred from membrane-bound dye transfer and a change in the contact area. Hemifusion was observed as a final stable state and as an intermediate to fusion of vesicles composed of charged phospholipids plus zwitterionic phospholipids. Hemifusion occurred in one of three ways following adhesion: either delayed with an abrupt increase in area of contact, immediately with a gradual increase in area of contact, or with retraction during which adherent vesicles dissociated from a flat contact to a point contact. Phosphatidylethanolamine strongly promoted immediate hemifusion; the resultant hemifused state was stable and seldom underwent complete fusion. Although sometimes single contacts between vesicles led to rupture of both, in other cases, a single vesicle underwent multiple fusion events. Direct observation has unequivocally demonstrated the fusion of two, isolated bilayer-bounded bodies to yield a stable, non-leaky product, as occurs in cells, in the absence of proteins. Received: 25 November 1998/Revised: 23 March 1999  相似文献   

19.
In video sequence-based iris recognition system, the problem of making full use of relationship and correlation among frames still remains to be solved. A brand new template level multimodal fusion algorithm inspired by human cognition manner is proposed. In that a non-isolated geometrical manifold, named Hyper Sausage Chain due to its sausage shape, is trained using the frames from a pattern class for representing an iris class in feature space. We can classify any input iris by observing which manifold it locates in. This process is closer to the function of human being, which takes 'matter cognition' instead of 'matter classification' as its basic principle. The experiments on self-developed JLUBR-IRIS dataset with several video sequences per person demonstrate the effectiveness and usability of the proposed algorithm for video sequence-based iris recognition. Fur- thermore, the comparative experiments on public CASIA-I and CASIA-V4-Interval datasets show that our method can also achieve improved performance of image-based iris recognition system, provided enough samples are involved in training stage.  相似文献   

20.
Membrane fusion of a phospholipid vesicle with a planar lipid bilayer is preceded by an initial prefusion stage in which a region of the vesicle membrane adheres to the planar membrane. A resonance energy transfer (RET) imaging microscope, with measured spectral transfer functions and a pair of radiometrically calibrated video cameras, was used to determine both the area of the contact region and the distances between the membranes within this zone. Large vesicles (5-20 microns diam) were labeled with the donor fluorophore coumarin- phosphatidylethanolamine (PE), while the planar membrane was labeled with the acceptor rhodamine-PE. The donor was excited with 390 nm light, and separate images of donor and acceptor emission were formed by the microscope. Distances between the membranes at each location in the image were determined from the RET rate constant (kt) computed from the acceptor:donor emission intensity ratio. In the absence of an osmotic gradient, the vesicles stably adhered to the planar membrane, and the dyes did not migrate between membranes. The region of contact was detected as an area of planar membrane, coincident with the vesicle image, over which rhodamine fluorescence was sensitized by RET. The total area of the contact region depended biphasically on the Ca2+ concentration, but the distance between the bilayers in this zone decreased with increasing [Ca2+]. The changes in area and separation were probably related to divalent cation effects on electrostatic screening and binding to charged membranes. At each [Ca2+], the intermembrane separation varied between 1 and 6 nm within each contact region, indicating membrane undulation prior to adhesion. Intermembrane separation distances < or = 2 nm were localized to discrete sites that formed in an ordered arrangement throughout the contact region. The area of the contact region occupied by these punctate attachment sites was increased at high [Ca2+]. Membrane fusion may be initiated at these sites of closest membrane apposition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号