首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
2.
This study determined the ratio between glenohumeral and three-dimensional scapular motion during arm elevation and lowering in 91 individuals without shoulder pain. Scapular kinematics were assessed using an electromagnetic tracking device. Individuals performed 3 repetitions of elevation and lowering of the arm in the sagittal plane. Two-way ANOVAs (interval: 30–60°, 60–90°, 90–120° x phase: elevation and lowering) and paired t-tests were used for data analysis. For scapular internal/external rotation, lesser scapular internal rotation contribution was found during the 60–90° interval as compared to the 90–60° interval. Lesser scapular external rotation was identified in the 60–30° interval of arm lowering. The ratio was greater during arm elevation (1.89) compared to lowering (1.74) across the entire motion arc. For scapular upward rotation, greater upward rotation contribution was observed during arm elevation at the 30–60° interval, and less scapular downward rotation contribution in the final range of arm lowering. For scapular tilt, lesser scapular posterior tilt contribution during arm elevation was observed compared to arm lowering. The ratios between glenohumeral elevation/lowering and each individual scapulothoracic motion showed either differences between intervals and/or between elevation and lowering during specific intervals in healthy individuals.  相似文献   

3.
In this study, the standard-sequence properties of a joint coordinate system were implemented for the glenohumeral joint by the use of a set of instantaneous geometrical planes. These are: a plane that is bound by the humeral long axis and an orthogonal axis that is the cross product of the scapular anterior axis and this long axis, and a plane that is bounded by the long axis of the humerus and the cross product of the scapular lateral axis and this long axis. The relevant axes are updated after every decomposition of a motion component of a humeral position. Flexion, abduction and rotation are then implemented upon three of these axes and are applied in a step-wise uncoupling of an acquired humeral motion to extract the joint coordinate system angles. This technique was numerically applied to physiological kinematics data from the literature to convert them to the joint coordinate system and to visually reconstruct the motion on a set of glenohumeral bones for validation.  相似文献   

4.
Conclusions about normal and pathologic shoulder motion are frequently made from studies using skin surface markers, yet accuracy of such sensors representing humeral motion is not well known. Nineteen subjects were investigated with flock of birds electromagnetic sensors attached to transcortical pins placed into the scapula and humerus, and a thermoplastic cuff secured on the arm. Subjects completed two repetitions of raising and lowering the arm in the sagittal, scapular and coronal planes, as well as shoulder internal and external rotation with the elbow at the side and abducted to 90°. Humeral motion was recorded simultaneously from surface and bone fixed sensors. The average magnitude of error was calculated for the surface and bone fixed measurements throughout the range of motion. ANOVA tested for differences across angles of elevation, raising and lowering, and differences in body mass index. For all five motions tested, the plane of elevation rotation average absolute error ranged from 0-2°, while the humeral elevation rotation average error ranged from 0-4°. The axial rotation average absolute error was much greater, ranging from 5° during elevation motions to approaching 30° at maximum excursion of internal/external rotation motions. Average absolute error was greater in subjects with body mass index greater than 25. Surface sensors are an accurate way of measuring humeral elevation rotations and plane of elevation rotations. Conversely, there is a large amount of average error for axial rotations when using a humeral cuff to measure glenohumeral internal/external rotation as the primary motion.  相似文献   

5.
Trunk rotation often accompanies humeral elevation, during daily activities as well as sports activities. Earlier studies have demonstrated that changes in spinal posture contribute to scapular motion during humeral elevation. However, the effect of trunk rotation on scapular kinematics during humeral elevation has received scant attention. This study aimed to clarify how trunk rotation affects scapular kinematics and muscle activities during humeral elevation. Electromagnetic motion capture and electromyography were used to assess scapular and clavicular motion and muscle activity in the right and left sides of 12 healthy young men. The subjects were seated and instructed to elevate both arms with the trunk in neutral, ipsilaterally rotated, or contralaterally rotated position. Ipsilaterally rotated trunk position decreased the internal rotation (by 5°, relative to neutral trunk position) and increased the upward rotation (by 4°, relative to neutral trunk position) of the scapula. Trunk position did not affect clavicular motion during humeral movement. Electromyography showed that contralaterally rotated trunk position increased the activity of the upper trapezius and serratus anterior muscles and decreased the activity of the lower trapezius. Therapists should consider the importance of trunk rotation, which may be the key to developing more efficient rehabilitation programs.  相似文献   

6.
Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p < 0.01). Method of measurement interacted with axial rotation in anterior/posterior tilt and protraction/retraction (p < 0.01). The AMC had strong agreement with the reference stylus than the locator for the majority of humeral elevations, planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations.  相似文献   

7.
We aimed to describe 3D scapular kinematics and scapulohumeral rhythm (SHR) in glenohumeral (GH) osteoarthritis shoulders compared to unaffected shoulders and to compare the abnormal scapular kinematic schema for GH osteoarthritis with that for frozen shoulder. Thirty-two patients with stiff shoulder (16 with GH osteoarthritis and 16 with frozen shoulder) performed maximal arm elevation in two planes, sagittal and frontal. Scapular rotations and humeral elevation of the affected and unaffected shoulders were measured by the Polhemus Fastrak electromagnetic system. Patients with GH osteoarthritis were older, had longer disease duration (p<0.001) and less restricted humeral elevation in the frontal plane (p=0.01). Protraction was significantly lower for the affected shoulders except for arm elevation in the frontal plane in the GH osteoarthritis group. Furthermore, protraction was lower with frozen shoulder than GH osteoarthritis during arm elevation in the frontal plane. Scapular lateral rotation and SHR were significantly higher for the affected shoulders in both groups whatever the plane of elevation. SHR showed a fair to moderate negative correlation with maximal humeral elevation in both groups and appears to be higher with frozen shoulder than GH osteoarthritis. In addition, SHR of the affected shoulder showed a fair to moderate correlation with disease duration only with GH osteoarthritis. Scapular tilt did not differ between affected and unaffected sides and was not influenced by type of disease. In conclusion, the increased scapular lateral rotation described in frozen shoulder is also observed in GH osteoarthritis. SHR of the affected shoulder is inversely related to severity of limitation of shoulder range of motion, which suggests a compensatory pattern.  相似文献   

8.
BACKGROUND. To describe 3D shoulder joint movements, the International Society of Biomechanics (ISB) recommends using segment coordinate systems (SCSs) on the humerus, scapula and thorax, and joint coordinate systems (JCSs) on the shoulder. However, one of the remaining problems is how to define the zero angles when the arm is in an initial reference position. The aim of this paper is to compare various methods of determining the JCSs of the shoulder that make it possible to define the zero angles of the arm in the resting position. METHODS. Able-bodied subjects performed elevation movements in the scapular plane, specifically neutral, internal and external rotations of the humerus. The initial humerus position (at the beginning of the arm movement) and range of motion were analysed for the purpose of clinical interpretation of arm attitude and movement. The following four different JCSs were explored: (1) the standard JCS, defined as recommended by the ISB, (2) a first aligned JCS, where the humerus SCS is initially aligned with the scapula SCS, (3) a second aligned JCS, where the opposite operation is performed and 4) a third aligned JCS, where both the humerus and the scapular SCS are initially aligned with the thorax SCS. FINDINGS. The second aligned JCS was the only method that did not produce any exaggerated range of movement in either anatomical plane. INTERPRETATION. Mathematical JCS alignment allows clearer clinical interpretation of arm attitude and movement.  相似文献   

9.
Shoulder pain is a common clinical problem affecting most individuals in their lifetime. Despite the high prevalence of rotator cuff pathology in these individuals, the pathogenesis of rotator cuff disease remains unclear. Position and motion related mechanisms of rotator cuff disease are often proposed, but poorly understood. The purpose of this study was to determine the impact of systematically altering glenohumeral plane on subacromial proximities across arm elevation as measures of tendon compression risk. Three-dimensional models of the humerus, scapula, coracoacromial ligament, and supraspinatus were reconstructed from MRIs in 20 subjects. Glenohumeral elevation was imposed on the humeral and supraspinatus tendon models for three glenohumeral planes, which were chosen to represent flexion, scapular plane abduction, and abduction based on average values from a previous study of asymptomatic individuals. Subacromial proximity was quantified as the minimum distance between the supraspinatus tendon and coracoacromial arch (acromion and coracoacromial ligament), the surface area of the supraspinatus tendon within 2 mm proximity to the coracoacromial arch, and the volume of intersection between the supraspinatus tendon and coracoacromial arch. The lowest modeled subacromial supraspinatus compression measures occurred during flexion at lower angles of elevation. This finding was consistent across all three measures of subacromial proximity. Knowledge of this range of reduced risk may be useful to inform future studies related to patient education and ergonomic design to prevent the development of shoulder pain and dysfunction.  相似文献   

10.
The aim of this study is to determine the errors of scapular localisation due to skin relative to bone motion with an optoelectronic tracking system. We compared three-dimensional (3D) scapular positions obtained with skin markers to those obtained through palpation of three scapular anatomical landmarks. The scapular kinematics of nine subjects were collected. Static positions of the scapula were recorded with the right arm elevated at 0°, 40°, 80°, 120° and 160° in the sagittal plane. Palpation and subsequent digitisation of anatomical landmarks on scapula and thorax were done at the same positions. Scapular 3D orientation was also computed during 10 repeated movements of arm elevation between 0° and 180°. Significant differences in scapular kinematics were seen between static positions and palpation when considering anterior/posterior tilt and upward/downward rotation at angles over 120° of humeral elevation and only at 120° for internal/external rotation. There was no significant difference between positions computed during static positions and during the movement for the three scapular orientations. A rotation correction model is presented in order to reduce the errors between static position and palpation measurement.  相似文献   

11.
12.
13.
Background. To describe 3D shoulder joint movements, the International Society of Biomechanics (ISB) recommends using segment coordinate systems (SCSs) on the humerus, scapula and thorax, and joint coordinate systems (JCSs) on the shoulder. However, one of the remaining problems is how to define the zero angles when the arm is in an initial reference position. The aim of this paper is to compare various methods of determining the JCSs of the shoulder that make it possible to define the zero angles of the arm in the resting position.

Methods. Able-bodied subjects performed elevation movements in the scapular plane, specifically neutral, internal and external rotations of the humerus. The initial humerus position (at the beginning of the arm movement) and range of motion were analysed for the purpose of clinical interpretation of arm attitude and movement. The following four different JCSs were explored: (1) the standard JCS, defined as recommended by the ISB, (2) a first aligned JCS, where the humerus SCS is initially aligned with the scapula SCS, (3) a second aligned JCS, where the opposite operation is performed and 4) a third aligned JCS, where both the humerus and the scapular SCS are initially aligned with the thorax SCS.

Findings. The second aligned JCS was the only method that did not produce any exaggerated range of movement in either anatomical plane.

Interpretation. Mathematical JCS alignment allows clearer clinical interpretation of arm attitude and movement.  相似文献   

14.
In order to analyze shoulder joint movements, the authors use a ZEBRIS CMS-HS ultrasound-based movement analysis system. In essence, the measurement involves the determination of the spatial position of the 16 anatomical points, which are specified on the basis of the coordinates of ultrasound-based triplets positioned on the upper limb, the scapula, and the thorax; their spatial position is measured in the course of motion. Kinematic characteristics of 74 shoulder joints of 50 healthy persons were identified during elevation in the plane of the scapula. Kinematic characteristics of motion were identified by scapulothoracic, glenohumeral, and humeral elevation angles; range of angles; scapulothoracis and glenohumeral rhythm; scapulothoracic, glenohumeral, and scapuloglenoid ratios; and the relative displacement between the rotation centers of the humerus and the scapula. Motion of the humerus and the scapula relative to each other was characterized by their rotation as well as the relative displacement between the rotation centers of scapula and humerus. The biomechanical model of the shoulder joint during elevation can be described by analyzing the results of the measurements performed.  相似文献   

15.
The most recent non-invasive methods for the recording of scapular motion are based on an acromion marker (AM) set and a single calibration (SC) of the scapula in a resting position. However, this method fails to accurately measure scapular kinematics above 90° of arm elevation, due to soft tissue artifacts of the skin and muscles covering the acromion. The aim of this study was to evaluate the accuracy, and inter-trial and inter-session repeatability of a double calibration method (DC) in comparison with SC. The SC and DC data were measured with an optoelectronic system during arm flexion and abduction at different angles of elevation (0-180°). They were compared with palpation of the scapula using a scapula locator. DC data was not significantly different from palpation for 5/6 axes of rotation tested (Y, X, and Z in abduction and flexion), where as SC showed significant differences for 5/6 axes. The root mean square errors ranged from 2.96° to 4.48° for DC and from 6° to 9.19° for SC. The inter-trial repeatability was good to excellent for SC and DC. The inter-session repeatability was moderate to excellent for SC and moderate to good for DC. Coupling AM and DC is an easy-to-use method, which yields accurate and reliable measurements of scapular kinematics for the complete range of arm motion. It can be applied to the measurement of shoulder motion in many fields (sports, orthopaedics, and rehabilitation), especially when large ranges of arm motion are required.  相似文献   

16.
Myosin VI is an unconventional motor protein with unusual motility properties such as its direction of motion and path on actin and a large stride relative to its short lever arms. To understand these features, the rotational dynamics of the lever arm were studied by single-molecule polarized total internal reflection fluorescence (polTIRF) microscopy during processive motility of myosin VI along actin. The axial angle is distributed in two peaks, consistent with the hand-over-hand model. The changes in lever arm angles during discrete steps suggest that it exhibits large and variable tilting in the plane of actin and to the sides. These motions imply that, in addition to the previously suggested flexible tail domain, there is a compliant region between the motor domain and lever arm that allows myosin VI to accommodate the helical position of binding sites while taking variable step sizes along the actin filament.  相似文献   

17.
The shoulder complex has a larger range of motion (ROM) than any other joint complex in the human body, leaving it prone to numerous injuries. Objective kinematic analysis could yield useful functional insights that may assist clinical practice. Non-invasive optoelectronic motion analysis techniques have been used to assess the shoulders of five healthy subjects performing ROM tasks and 10 functional tasks of daily living. The four most demanding tasks - touching the side and back of the head, brushing the opposite side of the head, lifting an object to shoulder height and lifting an object to head height, required 78%, 60%, 61% and 71%, respectively, of the glenohumeral elevation necessary for full abduction in the scapular plane for the 10 shoulders. This has implications for clinical practice where maximum arm elevation is commonly used to determine a patient's ability to return to work and other everyday activities.  相似文献   

18.
It is currently unknown in which ways activity of the ab- and adductor shoulder muscles affects shoulder biomechanics (scapular kinematics and glenohumeral translation), and whether these changes are relevant for alterations of the subacromial space width. The objective of this experimental in vivo study was thus to test the hypotheses that potential changes of the subacromial space width (during antagonistic muscle activity) are caused by alterations of scapular kinematics and/or glenohumeral translation. The shoulders of 12 healthy subjects were investigated with an open MRI-system at 30 degrees, 60 degrees, 90 degrees, 120 degrees and 150 degrees of arm elevation. A force of 15N was applied to the distal humerus, once causing isometric contraction of the abductors and once contraction of the adductors. The scapulo-humeral rhythm, scapular tilting and glenohumeral translation were calculated from the MR image data for both abducting and adducting muscle activity. Adducting muscle activity led to significant increase of the subacromial space width in all arm positions. The scapulo-humeral rhythm (2.2-2.5) and scapular tilting (2-4 degrees) remained relatively constant during elevation, no significant difference was found between abducting and adducting muscle activity. The position of the humerus relative to the glenoid was, however, significantly (p < 0.05) different (inferior and anterior) for adducting versus abducting muscle activity in midrange elevation (60-120 degrees). These data show that the subacromial space can be effectively widened by adducting muscle activity, by affecting the position of the humerus relative to the glenoid. This effect may be employed for conservative treatment of the impingement syndrome.  相似文献   

19.
The purpose of this study was to assess the effect of standardized anterior glenohumeral capsular lesions on axial humeral rotation in a full arc of glenohumeral elevation. Using a testing apparatus, the range of internal and external humeral rotation was assessed in an arc of glenohumeral elevation in the scapular plane with steps of 15 degrees in six isolated shoulder joint specimens. Cutting of the glenohumeral joint capsule 1 cm laterally from, and parallel to the glenoid rim was performed in seven steps of 1 cm till the anterior capsule was cut. Capsular lesions were made in three ways: from inferior, from superior and from the middle of the capsule. Anterior capsular lesions resulted in significant increase of external humeral rotation. This occurred particularly at 15-60 degrees glenohumeral elevation. Lesions of the inferior part of the capsule mainly increased external rotation at 30-60 degrees glenohumeral elevation, lesions of the superior part mainly in lower elevation angles and lesions of the middle more gradually in the range till 60 degrees of glenohumeral elevation. Cutting of the anterior glenohumeral capsule barely increased passive axial humeral rotation at elevation angles over 60 degrees. Above 60 degrees glenohumeral elevation, tightening of the inferior posterior glenohumeral joint capsule prevented both internal and, increasingly, external humeral rotation. From these observations it is concluded that increased external rotation correlates with progressive anterior capsular lesions, mainly below 60 degrees glenohumeral elevation. To assess anterior glenohumeral capsular lesions in patients, axial humeral rotation tests should probably not exceed 60 degrees glenohumeral elevation, i.e. 90 degrees thoracohumeral elevation.  相似文献   

20.
Assessments of shoulder dynamics (e.g. the inertial, viscous, and stiffness properties of the joint) can provide important insights into the stability of the joint at rest and during volitional contraction. The purpose of this study was to investigate how arm posture influences shoulder dynamics while generating pushing or pulling torques in the horizontal plane. Sixteen healthy participants were examined in seven postures encompassing a large workspace of the shoulder. At each posture, the participant’s shoulder was rapidly perturbed while measuring the resultant change in shoulder torque about the glenohumeral axis. Participants were examined both at rest and while producing horizontal flexion and extension torques scaled to 15% of a maximum voluntary contraction. Shoulder stiffness, viscosity, and damping ratio were estimated using impedance-based matching, and changes in these outcome measures with torque level, elevation angle, and plane of elevation angle were explored with a linear mixed effects model. Shoulder stiffness was found to decrease with increasing elevation angles (p < 0.001) without subsequent changes in viscosity, leading to a greater damping ratios at higher elevation angles (p < 0.001). Shoulder stiffness, viscosity, and damping ratio (all p < 0.05) were all found to significantly increase as the plane of elevation of the arm was increased. The relationship between the viscosity, stiffness and the damping ratio of the shoulder is one that the central nervous system must regulate in order to maintain stability, protect against injury, and control the shoulder joint as the inertial and muscle contributions change across different arm postures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号