首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 36 毫秒
1.
This review presents an introduction to Raman scattering and describes the various Raman spectroscopy, Raman microscopy, and chemical imaging techniques that have demonstrated utility in biocolloidal self-assemblies, pharmaceutical drug delivery systems, and pulmonary research applications. Recent Raman applications to pharmaceutical aerosols in the context of pulmonary inhalation aerosol delivery are discussed. The "molecular fingerprint" insight that Raman applications provide includes molecular structure, drug-carrier/excipient interactions, intramolecular and intermolecular bonding, surface structure, surface and interfacial interactions, and the functional groups involved therein. The molecular, surface, and interfacial properties that Raman characterization can provide are particularly important in respirable pharmaceutical powders, as these particles possess a higher surface-area-to-volume ratio; hence, understanding the nature of these solid surfaces can enable their manipulation and tailoring for functionality at the nanometer level for targeted pulmonary delivery and deposition. Moreover, Raman mapping of aerosols at the micro- and nanometer level of resolution is achievable with new, sophisticated, commercially available Raman microspectroscopy techniques. This noninvasive, highly versatile analytical and imaging technique exhibits vast potential for in vitro and in vivo molecular investigations of pulmonary aerosol delivery, lung deposition, and pulmonary cellular drug uptake and disposition in unfixed living pulmonary cells.  相似文献   

2.
Pharmaceutical inhalation aerosols have been playing a crucial role in the health and well being of millions of people throughout the world for many years. The technology's continual advancement, the ease of use and the more desirable pulmonary-rather-than-needle delivery for systemic drugs has increased the attraction for the pharmaceutical aerosol in recent years. But administration of drugs by the pulmonary route is technically challenging because oral deposition can be high, and variations in inhalation technique can affect the quantity of drug delivered to the lungs. Recent advances in nanotechnology, particularly drug delivery field have encouraged formulation scientists to expand their reach in solving tricky problems related to drug delivery. Moreover, application of nanotechnology to aerosol science has opened up a new category of pharmaceutical aerosols (collectively known as nanoenabled-aerosols) with added advantages and effectiveness. In this review, some of the latest approaches of nano-enabled aerosol drug delivery system (including nano-suspension, trojan particles, bioadhesive nanoparticles and smart particle aerosols) that can be employed successfully to overcome problems of conventional aerosol systems have been introduced.  相似文献   

3.
Aerosol gene therapy   总被引:9,自引:0,他引:9  
Gene therapy is a novel field of medicine that holds tremendous therapeutic potential for a variety of human diseases. Targeting of therapeutic gene delivery vectors to the lungs can be beneficial for treatment of various pulmonary diseases such as lung cancer, cystic fibrosis, pulmonary hypertension, alpha-1 antitrypsin deficiency, and asthma. Inhalation therapy using formulations delivered as aerosols targets the lungs through the pulmonary airways. The instant access and the high ratio of the drug deposited within the lungs noninvasively are the major advantages of aerosol delivery over other routes of administration. Delivery of gene formulations via aerosols is a relatively new field, which is less than a decade old. However, in this short period of time significant developments in aerosol delivery systems and vectors have resulted in major advances toward potential applications for various pulmonary diseases. This article will review these advances and the potential future applications of aerosol gene therapy technology.  相似文献   

4.
Abstract

This overview will discuss our studies of liposomes aerosols to treat diseases of the lung and will entail (i) formulation and characterization of liposome aerosols, including dry liposome powder aerosols, (ii) modulation of the pharmacokinetic profile of liposomal drugs delivered by aerosol or intratracheal instillation, (iii) liposome-alveolar macrophage interactions in vitro and in vivo, and (iv) safety of liposome aerosols in vivo in mice, sheep and healthy human volunteers. Water-soluble agents can be retained in liposomes during aerosolization with air-pressure nebulizers within certain limitations of liposome composition, size, and operating conditions. Dry powder liposome aerosols have been formulated and deliver water-soluble encapsulated substances efficiently. Pharmacokinetic profiles of liposomal drugs delivered via intratracheal instillation exhibit typical slow release plasma profiles indicating that the carrier is the rate-limiting barrier for release. Accordingly, pulmonary mean residence times are significantly prolonged and systemic concentrations remain low. Liposomes do not inhibit the phagocytic activity of alveolar macrophages in vitro and in vivo, have no apparent histopathologic effects on lung architecture even after chronic administration, and do not alter dynamic compliance, lung resistance, paO2 and paCO2 in awake, unanesthetized sheep and in healthy human volunteers. In conclusion, liposomes are a promising innocuous aerosol delivery system for drugs to achieve prolonged localized drug concentrations in the lung or intracellular drug targeting to alveolar macrophages.  相似文献   

5.
Mycobacterium tuberculosis is the main cause of tuberculosis and is still a public health concern worldwide. This mycobacterium is transmitted through aerosols from human beings suffering from pulmonary tuberculosis to susceptible persons. To study this natural route of infection, we designed a new nose-only aerosol apparatus--system of aerosolisation of microorganisms (SAM)--in a carefully designed biohazard facility. For safety reasons, Mycobacterium smegmatis was first used to calibrate several parameters, such as inoculum density, atmospheric conditions (i.e. hygrometry) and particle size distribution. We present evidence that our apparatus is totally adapted to airborne delivery; the particle size of generated aerosol ranges from 1 to 7 microm, which is ideal for an infection by inhalation. We found that 99% of generated particles (<7 microm) could be retained by the respiratory tract, and among these particles, 62-79% (<3.3 microm) were able to reach pulmonary compartments. The next step was to simultaneously challenge 48 mice with M. tuberculosis in a highly reproducible way. We showed that a moderate dose (4 log10 colony-forming units (CFU) per mice) of M. tuberculosis was capable of causing progressive lung pathology and death in mice 30 days post-aerosolisation. Therefore, our apparatus, once calibrated, is easy to handle, safe, and can be used with any pathogen, which is spread by aerosol.  相似文献   

6.
The abilityto deliver proteins and peptides to the systemic circulation byinhalation has contributed to a rise in the number of inhalationtherapies under investigation. For most of these therapies, aerosolsare designed to comprise small spherical droplets or particles of massdensity near 1 g/cm3 and meangeometric diameter between ~1 and 3 µm, suitable for particlepenetration into the airways or lung periphery. Studies performedprimarily with liquid aerosols have shown that these characteristics ofinhaled aerosols lead to optimal therapeutic effect, both for local andsystemic therapeutic delivery. Inefficient drug delivery can stillarise, owing to excessive particle aggregation in an inhaler,deposition in the mouth and throat, and overly rapid particle removalfrom the lungs by mucocilliary or phagocytic clearance mechanisms. Toaddress these problems, particle surface chemistry and surfaceroughness are traditionally manipulated. Recent data indicate thatmajor improvements in aerosol particle performance may also be achievedby lowering particle mass density and increasing particle size, sincelarge, porous particles display less tendency to agglomerate than(conventional) small and nonporous particles. Also, large, porousparticles inhaled into the lungs can potentially release therapeuticsubstances for long periods of time by escaping phagocytic clearancefrom the lung periphery, thus enabling therapeutic action for periodsranging from hours to many days.

  相似文献   

7.
An experimental technique is presented for studying aerosols generated from lyophilized bacteria by using Escherichia coli B, Bacillus subtilis var. niger, Enterobacter aerogenes, and Pasteurella tularensis. An aerosol generator capable of creating fine particle aerosols of small quantities (10 mg) of lyophilized powder under controlled conditions of exposure to the atmosphere is described. The physical properties of the aerosols are investigated as to the distribution of number of aerosol particles with particle size as well as to the distribution of number of bacteria with particle size. Biologically unstable vegetative cells were quantitated physically by using 14C and Europium chelate stain as tracers, whereas the stable heat-shocked B. subtilis spores were assayed biologically. The physical persistence of the lyophilized B. subtilis aerosol is investigated as a function of size of spore-containing particles. The experimental result that physical persistence of the aerosol in a closed aerosol chamber increases as particle size is decreased is satisfactorily explained on the bases of electrostatic, gravitational, inertial, and diffusion forces operating to remove particles from the particular aerosol system. The net effect of these various forces is to provide, after a short time interval in the system (about 2 min), an aerosol of fine particles with enhanced physical stability. The dependence of physical stability of the aerosol on the species of organism and the nature of the suspending medium for lyophilization is indicated. Also, limitations and general applicability of both the technique and results are discussed.  相似文献   

8.

Background

Pulmonary drug delivery is characterized by short onset times of the effects and an increased therapeutic ratio compared to oral drug delivery. This delivery route can be used for local as well as for systemic absorption applying drugs as single substance or as a fixed dose combination. Drugs can be delivered as nebulized aerosols or as dry powders. A screening system able to mimic delivery by the different devices might help to assess the drug effect in the different formulations and to identify potential interference between drugs in fixed dose combinations. The present study evaluates manual devices used in animal studies for their suitability for cellular studies.

Methods

Calu-3 cells were cultured submersed and in air-liquid interface culture and characterized regarding mucus production and transepithelial electrical resistance. The influence of pore size and material of the transwell membranes and of the duration of air-liquid interface culture was assessed. Compounds were applied in solution and as aerosols generated by MicroSprayer IA-1C Aerosolizer or by DP-4 Dry Powder Insufflator using fluorescein and rhodamine 123 as model compounds. Budesonide and formoterol, singly and in combination, served as examples for drugs relevant in pulmonary delivery.

Results and Conclusions

Membrane material and duration of air-liquid interface culture had no marked effect on mucus production and tightness of the cell monolayer. Co-application of budesonide and formoterol, applied in solution or as aerosol, increased permeation of formoterol across cells in air-liquid interface culture. Problems with the DP-4 Dry Powder Insufflator included compound-specific delivery rates and influence on the tightness of the cell monolayer. These problems were not encountered with the MicroSprayer IA-1C Aerosolizer. The combination of Calu-3 cells and manual aerosol generation devices appears suitable to identify interactions of drugs in fixed drug combination products on permeation.  相似文献   

9.
Inhaled vasodilator therapy for pulmonary hypertension may decrease the systemic side effects commonly observed with systemic administration. Inhaled medications only reach ventilated areas of the lung, so local vasodilation may improve ventilation-perfusion matching and oxygenation. We compared the effects of intravenous vs. aerosolized treprostinil on pulmonary and systemic hemodynamics in an unanesthetized sheep model of sustained acute pulmonary hypertension. Acute, stable pulmonary hypertension was induced in instrumented unanesthetized sheep by infusing a PGH(2) analog, U-44069. The sheep were then administered identical doses of treprostinil either intravenously or by aerosol. Systemic and pulmonary hemodynamics were recorded during each administration. Both intravenous and aerosol delivery of treprostinil reduced pulmonary vascular resistance and pulmonary arterial pressure, but the effect was significantly greater with aerosol delivery (P < 0.05). Aerosol delivery of treprostinil had minimal effects on systemic hemodynamics, whereas intravenous delivery increased heart rate and cardiac output and decreased left atrial pressure and systemic blood pressure. Aerosol delivery of the prostacyclin analog treprostinil has a greater vasodilatory effect in the lung with minimal alterations in systemic hemodynamics compared with intravenous delivery of the drug. We speculate that this may result from treprostinil stimulated production of vasodilatory mediators from pulmonary epithelium.  相似文献   

10.
One important research area of broad interest is the development of highly efficient drug delivery systems for desired site deposition and uptake. For example, controlled drug aerosol release and targeting to specific regions of the lung is a novel way to combat lung diseases, diabetes, virus infections, cancers, etc. Determination of feasible air-particle streams is a prerequisite for the development of such delivery devices, say, smart inhalers. The concept of "controlled particle release and targeting" is introduced and results are discussed for a representative model of bronchial lung airways afflicted with hemispherical tumors of different sizes and locations. It is shown that under normal particle inlet conditions a particle mass fraction of only up to 11% may deposit on the surface of a specific tumor with critical radius r/R approximately 1.25, while a controlled particle release achieves deposition fractions of 35 to 92% for a realistic combination of inlet Stokes and Reynolds numbers, depending mainly on tumor size. Furthermore, with the controlled release and targeting approach nearby healthy tissue is hardly impacted by the typically aggressive drug aerosols. Assuming laminar, quasi-steady, three-dimensional air flow and spherical non-interacting micron-particles in sequentially bifurcating rigid airways, the results were obtained using a validated commercial finite-volume code with user-enhanced programs on a high-end engineering workstation. The new concept is generic and hence should be applicable to other regions of the respiratory system as well.  相似文献   

11.
《Molecular membrane biology》2013,30(4-6):190-205
Abstract

Vascular-targeted drug delivery systems could provide more efficient and effective pharmaceutical interventions for treating a variety of diseases including cardiovascular, pulmonary, inflammatory, and malignant disorders. However, several factors must be taken into account when designing these systems. The diverse blood hemodynamics and rheology, and the natural clearance process that tend to decrease the circulation time of foreign particles all lessen the probability of successful carrier interaction with the vascular wall. An effective vascular-targeted drug delivery system must be able to navigate through the bloodstream while avoiding immune clearance, attach to the vascular wall, and release its therapeutic cargo at the intended location. This review will summarize and analyze current literature reporting on (1) nanocarrier fabrication methods and materials that allow for optimum therapeutic encapsulation, protection, and release; (2) localization and binding dynamics of nanocarriers as influenced by hemodynamics and blood rheology in medium-to-large vessels; (3) blood cells' responses to various types of nanocarrier compositions and its effects on particle circulation time; and (4) properties that affect nanocarrier internalization at the target site.  相似文献   

12.
Abstract

Vascular-targeted drug delivery systems could provide more efficient and effective pharmaceutical interventions for treating a variety of diseases including cardiovascular, pulmonary, inflammatory, and malignant disorders. However, several factors must be taken into account when designing these systems. The diverse blood hemodynamics and rheology, and the natural clearance process that tend to decrease the circulation time of foreign particles all lessen the probability of successful carrier interaction with the vascular wall. An effective vascular-targeted drug delivery system must be able to navigate through the bloodstream while avoiding immune clearance, attach to the vascular wall, and release its therapeutic cargo at the intended location. This review will summarize and analyze current literature reporting on (1) nanocarrier fabrication methods and materials that allow for optimum therapeutic encapsulation, protection, and release; (2) localization and binding dynamics of nanocarriers as influenced by hemodynamics and blood rheology in medium-to-large vessels; (3) blood cells' responses to various types of nanocarrier compositions and its effects on particle circulation time; and (4) properties that affect nanocarrier internalization at the target site.  相似文献   

13.

Background

The pulmonary residence time of inhaled glucocorticoids as well as their rate and extend of absorption into systemic circulation are important facets of their efficacy-safety profile. We evaluated a novel approach to elucidate the pulmonary absorption of an inhaled glucocorticoid. Our objective was to monitor and compare the combined process of drug particle dissolution, pro-drug activation and time course of initial distribution from human lung tissue into plasma for two different glucocorticoid formulations.

Methods

We chose beclomethasone dipropionate (BDP) delivered by two different commercially available HFA-propelled metered dose inhalers (Sanasthmax®/Becloforte™ and Ventolair®/Qvar™). Initially we developed a simple dialysis model to assess the transfer of BDP and its active metabolite from human lung homogenate into human plasma. In a novel experimental setting we then administered the aerosols into the bronchus of an extracorporally ventilated and reperfused human lung lobe and monitored the concentrations of BDP and its metabolites in the reperfusion fluid.

Results

Unexpectedly, we observed differences between the two aerosol formulations Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ in both the dialysis as well as in the human reperfusion model. The HFA-BDP formulated as Ventolair®/Qvar™ displayed a more rapid release from lung tissue compared to Sanasthmax®/Becloforte™. We succeeded to explain and illustrate the observed differences between the two aerosols with their unique particle topology and divergent dissolution behaviour in human bronchial fluid.

Conclusion

We conclude that though the ultrafine particles of Ventolair®/Qvar™ are beneficial for high lung deposition, they also yield a less desired more rapid systemic drug delivery. While the differences between Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ were obvious in both the dialysis and lung perfusion experiments, the latter allowed to record time courses of pro-drug activation and distribution that were more consistent with results of comparable clinical trials. Thus, the extracorporally reperfused and ventilated human lung is a highly valuable physiological model to explore the lung pharmacokinetics of inhaled drugs.  相似文献   

14.
The deposition patterns of large-particle microbiological aerosols within the respiratory tract are not well characterized. A novel system (the flow-focusing aerosol generator [FFAG]) which enables the generation of large (>10-μm) aerosol particles containing microorganisms under laboratory conditions was characterized to permit determination of deposition profiles within the murine respiratory tract. Unlike other systems for generating large aerosol particles, the FFAG is compatible with microbiological containment and the inhalational challenge of animals. By use of entrapped Escherichia coli cells, Bacillus atrophaeus spores, or FluoSphere beads, the properties of aerosols generated by the FFAG were compared with the properties of aerosols generated using the commonly available Collison nebulizer, which preferentially generates small (1- to 3-μm) aerosol particles. More entrapped particulates (15.9- to 19.2-fold) were incorporated into 9- to 17-μm particles generated by the FFAG than by the Collison nebulizer. The 1- to 3-μm particles generated by the Collison nebulizer were more likely to contain a particulate than those generated by the FFAG. E. coli cells aerosolized using the FFAG survived better than those aerosolized using the Collison nebulizer. Aerosols generated by the Collison nebulizer and the FFAG preferentially deposited in the lungs and nasal passages of the murine respiratory tract, respectively. However, significant deposition of material also occurred in the gastrointestinal tract after inhalation of both the small (89.7%)- and large (61.5%)-particle aerosols. The aerosols generated by the Collison nebulizer and the FFAG differ with respect to mass distribution, distribution of the entrapped particulates, bacterial survival, and deposition within the murine respiratory tract.  相似文献   

15.
Aerosol particle size influences airway drug deposition. Current inhaler devices are inefficient, delivering a heterodisperse distribution of drug particle sizes where, at best, 20% reaches the lungs. Monodisperse aerosols are the appropriate research tools to investigate basic aerosol science concepts within the human airways. We hypothesized that engineering such aerosols of albuterol would identify the ideal bronchodilator particle size, thereby optimizing inhaled therapeutic drug delivery. Eighteen stable mildly to moderately asthmatic patients [mean forced expiratory volume in 1 s (FEV1) 74.3% of predicted] participated in a randomized, double-blind, crossover study design. A spinning-top aerosol generator was used to produce monodisperse albuterol aerosols that were 1.5, 3, and 6 microm in size, and also a placebo, which were inhaled at cumulative doses of 10, 20, 40, and 100 microg. Lung function changes and tolerability effects were determined. The larger particles, 6 and 3 microm, were significantly more potent bronchodilators than the 1.5-microm and placebo aerosols for FEV1 and for the forced expiratory flow between exhalation of 25 and 75% of forced vital capacity. A 20-microg dose of the 6- and 3-microm aerosols produced FEV1 bronchodilation comparable to that produced by 200 microg from a metered-dose inhaler. No adverse effects were observed in heart rate and plasma potassium. The data suggest that in mildly to moderately asthmatic patients there is more than one optimal beta2-agonist bronchodilator particle size and that these are larger particles in the higher part of the respirable range. Aerosols delivered in monodisperse form can enable large reductions of the inhaled dose without loss of clinical efficacy.  相似文献   

16.
Acute lung injury (ALI) is a severe disease characterized by alveolar neutrophilia, with limited treatment options and high mortality. Experimental models of ALI are key in enhancing our understanding of disease pathogenesis. Lipopolysaccharide (LPS) derived from gram positive bacteria induces neutrophilic inflammation in the airways and lung parenchyma of mice. Efficient pulmonary delivery of compounds such as LPS is, however, difficult to achieve. In the approach described here, pulmonary delivery in mice is achieved by challenge to aerosolized Pseudomonas aeruginosa LPS. Dissolved LPS was aerosolized by a nebulizer connected to compressed air. Mice were exposed to a continuous flow of LPS aerosol in a Plexiglas box for 10 min, followed by 2 min conditioning after the aerosol was discontinued. Tracheal intubation and subsequent bronchoalveolar lavage, followed by formalin perfusion was next performed, which allows for characterization of the sterile pulmonary inflammation. Aerosolized LPS generates a pulmonary inflammation characterized by alveolar neutrophilia, detected in bronchoalveolar lavage and by histological assessment. This technique can be set up at a small cost with few appliances, and requires minimal training and expertise. The exposure system can thus be routinely performed at any laboratory, with the potential to enhance our understanding of lung pathology.  相似文献   

17.
BACKGROUND: Cystic fibrosis is an autosomal recessive disease affecting approximately 1 in 2500 live births. Introducing the cDNA that codes for normal cystic fibrosis transmembrane conductance regulator (CFTR) to the small airways of the lung could result in restoring the CFTR function. A number of vectors for lung gene therapy have been tried and adeno-associated virus (AAV) vectors offer promise. The vector is delivered to the lung using a breath-actuated jet nebulizer. The purpose of this project was to determine the aerosolized AAV (tgAAVCF) particle size distribution (PSD) in order to calculate target doses for lung delivery. METHODS: A tgAAVCF solution was nebulized using the Pari LC Plus (n = 3), and the PSD was determined by coupling laser diffraction and inertial impaction (NGI) techniques. The NGI allowed for quantification of the tgAAVCF at each stage of impaction, ensuring that rAAV-CFTR vector is present and not empty particles. Applying the results to mathematical algorithms allowed for the calculation of expected pulmonary deposition. RESULTS: The mass median diameter (MMD) for the tgAAVCF was 2.78 +/- 0.43 microm. If the system works ideally and the patient only receives aerosol on inspiration, the patient would receive 47 +/- 0% of the initial dose placed in the nebulizer, with 72 +/- 0.73% of this being deposited beyond the vocal cords. CONCLUSIONS: This technology for categorizing the pulmonary delivery system for lung gene therapy vectors can be adapted for advanced aerosol delivery systems or other vectors.  相似文献   

18.
The bolus delivery method is designed to deliver a dose to the desired location in the lung, and it has the advantage of fewer side effects and a more efficient way of delivery. Based upon the lung deposition model developed for continuously inhaling aerosols of constant concentration, a mathematical model of aerosol bolus deposition is proposed. The calculated results show that the recovery depends on the bolus penetration depth, flow rate, particle size, breath holding time and bolus volume. Three sets of published experimental data with different controlling factors (particle size, flow rate and breath holding time) are adopted to make the quantitative comparisons with the calculated results. The predictions and data for the low intrinsic motion particles (~1 μm) have good agreement, as do the coarse particles in the shallow airways region. For females, the recovery was found to be consistently lower than that for males.  相似文献   

19.
The bolus delivery method is designed to deliver a dose to the desired location in the lung, and it has the advantage of fewer side effects and a more efficient way of delivery. Based upon the lung deposition model developed for continuously inhaling aerosols of constant concentration, a mathematical model of aerosol bolus deposition is proposed. The calculated results show that the recovery depends on the bolus penetration depth, flow rate, particle size, breath holding time and bolus volume. Three sets of published experimental data with different controlling factors (particle size, flow rate and breath holding time) are adopted to make the quantitative comparisons with the calculated results. The predictions and data for the low intrinsic motion particles (~1 μm) have good agreement, as do the coarse particles in the shallow airways region. For females, the recovery was found to be consistently lower than that for males.  相似文献   

20.
Liposomes are potential drug carriers for pulmonary drug delivery: They can be prepared from phospholipids, which are endogenous to the respiratory tract as a component of pulmonary surfactant, and at an appropriate dose liposomes do not pose a toxicological risk to this organ. Among the various categories of drug that benefit from liposomal entrapment is the anti-inflammatory enzyme superoxide dismutase, thus prolonging its biological half-life. The delivery of liposomes by nebulization is hampered by stability problems, like physical and chemical changes that may lead to chemical degradation and leakage of the encapsulated drug. Here we present data of liposomes aerosolized with a novel electronic nebulizer based on a vibrating membrane technology (PARI eFlow?), which amends drawbacks like liposomes degradation and product release. The data acquisition included aerosol properties such as aerodynamic particle size, nebulization efficiency, and liposome leakage upon nebulization. In conclusion, this study shows the ability of the PARI eFlow? to nebulize high amounts of liposomal recombinant human superoxide dismutase with reduced vesicle disruption tested in an enclosing experimental protocol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号