首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this prospective, controlled clinical investigation was to find out if there is a difference in the capsular contracture rate between silicone implants with a smooth or textured surface as the only difference. Twenty-five women with bilateral mammary hypoplasia underwent mammary augmentation. All got a textured implant on one side and a smooth implant on the other. The implants were placed subglandularly. Follow-up examinations were done on six occasions. Three parameters were used for estimation of the tendency to capsular contracture: (1) the patient's opinion on differences in hardness of the breasts, (2) the investigator's classification of capsular contracture, and (3) applanation tonometry. At the end of the follow-up period, after 1 year, all parameters showed with no doubt that the breasts augmented with textured implants had a lower tendency to develop contracting capsules than the breasts augmented with smooth implants.  相似文献   

2.
Detection of subclinical infection in significant breast implant capsules   总被引:8,自引:0,他引:8  
The pathogenesis of fibrous capsular contracture after augmentation mammaplasty is still debated. One hypothesis implicates low-grade bacterial infections as a cause. The presence of a staphylococcal biofilm in a patient with recurrent capsular contracture was previously reported. A comparative, prospective, blinded, clinical study of implants and capsules removed from patients with or without significant capsular contracture was conducted to investigate the association of biofilm contamination, breast implants, and capsular contracture.Capsule and implant samples obtained during explantation were tested by routine microbiological culture, sensitive broth culture (after maceration and sonication), and scanning electron microscopy. Clinical parameters were correlated with microbiological findings. A total of 48 implant and/or capsule samples were obtained from 27 breasts during a 22-month period. Of the 27 breasts, 19 exhibited significant contracture (Baker grade III/IV). The mean duration of implantation was 9.2 years (range, 0.4 to 26.0 years). Routine swab cultures obtained at the time of explantation were negative for bacterial growth for all samples. The sensitive broth culture technique yielded 24 positive samples (50 percent, n = 48). An analysis of capsules demonstrated that 17 of 19 samples obtained from patients with significant contracture were positive, compared with only one of eight samples obtained from patients with minimal or no contracture (p = 0.0006). Fourteen of the 17 positive cultures from significantly contracted breasts yielded coagulase-negative staphylococci, mainly, species of the Staphylococcus epidermidis group. The presence of coagulase-negative staphylococci was also significantly associated with capsular contracture (p = 0.01). There was no significant difference in the frequency of culture positivity for saline versus silicone implants (p = 0.885). Scanning electron microscopy confirmed the presence of extensive biofilm on implants and within capsules.Biofilm, in particular, S. epidermidis biofilm, was detected for a significant proportion of patients with capsular contracture. This implicates biofilm disease in the pathogenesis of contracture, and strategies for its prevention should be explored.  相似文献   

3.
Spear SL  Elmaraghy M  Hess C 《Plastic and reconstructive surgery》2000,105(4):1542-52; discussion 1553-4
The earliest silicone breast implants were smooth-surface, silicone rubber devices filled with either silicone gel or saline. Because of persistent problems with capsular contracture, polyurethane-covered silicone implants were developed as an alternative. Particularly in the short run, these alternatives proved highly successful at reducing the incidence of capsular contracture. By 1990, polyurethane-covered implants were rapidly becoming the preferred implant choice of many plastic surgeons, but for legal, regulatory, financial, and safety reasons they were withdrawn from the market by Bristol-Myers in 1991. Meanwhile, during the late 1980s, surface texturing and improved materials became available on other silicone breast implants and expanders. Most studies suggest that textured-surface silicone gel-filled implants, saline-filled implants, and tissue expanders have less frequent capsular contracture than their smooth-surface counterparts.  相似文献   

4.
Comparisons between results with randomly allotted silicone-gel and saline-filled prostheses in breast reconstruction after mastectomy led to the following conclusions. Neither prosthesis type is ideal. Leakage from saline-filled implants occurred in 2 of the 37 implants, with resultant deflation. Silicone prostheses had a significantly higher rate of capsular contracture [surgeon's evaluation: 54 percent capsular contracture for silicone-gel compared with 20 percent for saline-filled prostheses (p = 0.006); patients' evaluation for the same figures: 54 percent compared with 29 percent (p = 0.03)]. Other authors have shown the presence of silicone in the tissue around silicone-gel-filled silicone implants, but less or none around saline-filled silicone implants. Since the only difference between the two groups was the randomly allotted implants, we assume that the free silicone around silicone-gel-filled prostheses is the major cause of capsular contracture. Since the saline-filled implants showed a 20 percent capsular contracture rate, there could be other causes of capsular contracture in this study. For prevention of contracture, improved implant encapsulation and use of a less reactive filling substance seem to offer possibilities. Surgical technique should aim to preserve the integrity of the prosthesis.  相似文献   

5.
Although textured silicone breast implants have been shown to reduce the incidence of capsular contracture, there is little evidence if this effect is maintained in the long term. It has been 10 years since the double-blind randomized trial in which 53 patients received either Mentor smooth (26) or textured silicone gel implants (27). Of the 14 patients who were not known to have developed a contracture in the smooth group, 11 were reviewed. Three had bilateral contractures. In the textured group, 18 of the 24 patients not known to have contractures were reviewed. None had developed contractures. At 10 years, the incidence of capsular contracture was 65 percent of patients with smooth implants (an increase of 6 percent on the 3-year results) and 11 percent for the textured implant patients (no change on the 3-year results). A database containing the details of 1100 patients reinforces these results by examining the differences in contracture rates of textured, smooth, and polyurethane-coated implants. The effect of submuscular placement on reducing contracture rates regardless of texturing is discussed, as is the apparent increase in capsular contracture in patients who smoke.  相似文献   

6.
Smooth-walled silicone implants have been widely used in breast surgery. Capsular contracture, causing undesirable firmness and spherical deformity, has been a common problem. Recent studies suggest that polyurethane-covered breast implants are associated with a lower incidence of capsular contracture. The statistical methodology employed in some of these studies, however, may be subject to criticism. Between July of 1984 and June of 1990 (72 months), 427 polyurethane breast implants were used in 279 patients and 439 smooth prostheses were used in 250 patients for a variety of aesthetic and reconstructive procedures. The occurrence of capsular contracture was carefully monitored and then analyzed using the Kaplan-Meier method of survival analysis. This method is particularly well suited to analysis of these types of clinical data because it allows for the fact that contractures occur at varying intervals after surgery and that follow-up of patients is incomplete. The probability of capsular contracture with smooth-walled prostheses was found to be significantly greater than with polyurethane-covered implants in each group of patients studied (p less than 0.05). Other complications occurred at a similar rate regardless of prosthesis type. This study supports the belief that polyurethane breast implants have a lower contracture rate; furthermore, it introduces the Kaplan-Meier method for analyzing the outcome of alternative plastic surgical therapies.  相似文献   

7.
Ajmal N  Riordan CL  Cardwell N  Nanney LB  Shack RB 《Plastic and reconstructive surgery》2003,112(5):1455-61; discussion 1462-3
The development of capsular contracture is the most common complication associated with the insertion of breast implants. The authors studied the role of sodium 2-mercaptoethane sulfonate (mesna) in reduction of capsular formation in a rabbit model. Two 40-cc textured saline implants were placed dorsally into each of the 20 rabbits in the study. At the time of insertion of the implants, 10 ml of a 10% solution of mesna was instilled into one of the pockets and normal saline was instilled into the other. The implants were removed and a capsulectomy was performed at 5 months. The capsules were examined histologically for qualitative differences between the two groups. Quantitative analysis of the thickness of the capsule and the myofibroblast populations was also performed and compared between the two groups. The mean total thickness of the capsule around the implants was 496.8 microm in the mesna-treated group compared with 973.7 microm in the saline-treated group (p < 0.001). Likewise, the thickness of the myofibroblast layer was reduced in the mesna-treated group at 283.2 microm versus 555 microm in the saline-treated group (p < 0.0001). The capsules were also relatively less vascular in the mesna-treated group. Because of its ability to reduce the extent of capsular formation and to diminish development of myofibroblasts in the capsules, mesna would appear to be a useful adjunct in the prevention of capsular contracture formation.  相似文献   

8.
Little has been published regarding the treatment of patients with long-established capsular contracture after previous submuscular or subglandular breast augmentation. This study reviews 7 years of experience in treating established capsular contracture after augmentation mammaplasty by relocating implants to the "dual-plane" or partly subpectoral position. A retrospective chart review was performed on all patients who were treated for capsular contracture using this technique between 1993 and 1999. Data collected included the date of the original augmentation, the original implant location, date of revision and type of implant used, length of follow-up, outcome, and any ensuing complications. Different surgical techniques were used, depending on whether the prior implant was located in a subglandular or submuscular plane. All patients had revisions such that their implants were relocated to a dual plane, with the superior two thirds or so of the implant located beneath the pectoralis major muscle and the inferior one third located subglandularly. Of 85 patients reviewed, 54 had their original implants in a submuscular position and 31 had their initial augmentation in a subglandular position. Of the 54 patients whose implants were initially submuscular, 23 patients (43 percent) had silicone gel implants, 15 patients (28 percent) had double-lumen implants, and the remaining 16 patients (30 percent) had saline implants. Of the 31 patients whose implants were initially subglandular, 20 patients (65 percent) had silicone gel implants, three patients (10 percent) had double-lumen implants, and the remaining eight patients (26 percent) had saline implants. Fifty-one patients (60 percent) had replacement with saline implants (37 smooth saline, 14 textured saline), whereas 34 (40 percent) had silicone gel implants (seven smooth gel, 27 textured gel). The average time from previous augmentation to revision was 9 years 9 months. The average follow-up time after conversion to the dual-plane position was 11.5 months. Only three of 85 patients required reoperation for complications, all of which involved some degree of implant malposition. Of patients converted to the dual plane, 98 percent were free of capsular contracture and were Baker class I at follow-up, whereas 2 percent were judged as Baker class II. There were no Baker level III or IV contractures at follow-up. The dual-plane method of breast augmentation has proved to be an effective technique for correcting established capsular contracture after previous augmentation mammaplasty. This technique appears to be effective when performed with either silicone or saline-filled implants.  相似文献   

9.
H H Caffee  C Hathaway 《Plastic and reconstructive surgery》1990,86(4):708-10; discussion 711-4
Experiments were conducted in rabbits comparing polyurethane foam-covered implants with otherwise identical smooth silicone gel implants. Using five objective methods of measurement of capsular contracture, no significant difference could be identified. The foam-covered implants consistently developed capsular contracture, although in most cases this was of mild degree and would not have been clinically significant. In the two foam-covered implants with hard contractures, there was no evidence of hematoma or separation of the foam.  相似文献   

10.
Capsular contracture results in dissatisfaction and deformity among the 2 million women who have had silicone implants. The literature describes contracture rates as high as 74 percent. I present a comparison of rates and incidences of contracture in patients augmented with smooth and textured double-lumen silicone implants. A total of 165 "smooth" and 63 "textured" implant patients were included in this study, which spans 12 years, 1978-1990. All patients underwent bilateral aesthetic augmentation performed by the same surgeon. Of the 165 smooth implant patients, 74 (44.8 percent) experienced contractures requiring treatment. Of the 63 textured implant patients, 3 (4.8 percent) previous contracture patients experienced sudden fibrosis within 3 months. All others remained soft. It appears that deeply textured silicone surfaces delay or decrease the rate and incidence of clinical capsular contracture, at least for 2 years.  相似文献   

11.
Epidemiologic evidence does not support an association between silicone breast implants and connective tissue or other rheumatic diseases. However, a recent study has suggested that women with ruptured implants may be at increased risk of developing fibromyalgia. An analysis of adverse health outcomes according to breast implant rupture status was conducted in 238 unselected Danish women with cosmetic silicone breast implants. Ninety-two of the women had definite implant rupture, and 146 had intact implants as determined by magnetic resonance imaging. Before undergoing imaging, the women provided blood samples and completed a self-administered questionnaire. Women with ruptured implants overall, and the subgroup with extracapsular ruptures (n = 23), were compared with women with intact implants regarding a number of self-reported diseases and symptoms and the presence of specific autoantibodies, such as antinuclear antibodies, rheumatoid factor, and cardiolipin immunoglobulin G and M antibodies. Overall, there were no differences in the occurrence of self-reported diseases or symptoms or in the presence of autoantibodies between women with intact implants and women with ruptured implants, including extracapsular rupture. The only exception was capsular contracture, which was reported six times more frequently by women with extracapsular ruptures than by women with intact implants (OR, 6.3; 95 percent CI, 1.7 to 23.5). In conclusion, this study of unselected women with silicone breast implants could establish no association between silicone implant rupture and specific diseases or symptoms related to connective tissue disease or other rheumatic conditions, except for an excess of capsular contracture among women with extracapsular rupture.  相似文献   

12.
Noninvasive assessment of implant capsules   总被引:2,自引:0,他引:2  
The assessment of implant capsular contracture has been imprecise and vulnerable to observer bias. Attempts to measure capsules with instruments that measure implant deformability are influenced by surrounding breast tissue, subcutaneous fat, and skin. Xeromammography, B-mode ultrasound, and CT were employed in an effort to provide a noninvasive and accurate method of capsule assessment. Through two study phases, implants were placed bilaterally in a total of 21 rabbits. At 4 months, animals underwent radiologic assessment and were then sacrificed for direct implant capsule measurements. Mammographic measurements, more than ultrasound-derived measurements, strongly correlated with laboratory measures of capsular dimensions and deformability. Cross-table lateral mammographic views were more informative than traditional views, providing measures of diameter and height that both strongly correlated with laboratory measurements. CT is theoretically the most accurate method to assess contracture, but it is impractical because of expense and time requirements. The results indicate that radiologic assessment, in particular by xeromammography, of implant capsules is accurate, practical, and noninvasive. Mammography strongly correlates with laboratory measures of implant capsular contracture and therefore could be used in the clinical setting to assess capsular contracture.  相似文献   

13.
Long-term use of polyurethane breast prostheses: a 14-year experience   总被引:1,自引:0,他引:1  
I have used polyurethane prostheses for the past 14 years, implanting 220 implants into 130 patients who desired breast reconstruction after subcutaneous mastectomy or cancer ablation or simply breast augmentation. I theorize that a polyurethane-covered implant resists contracture, retaining its compressibility because the fibroblasts proliferate into the polyurethane in many different directions. When the fibrils contract, the forces of contracture counterbalance one another, resisting contracture. However, when smooth prostheses are implanted, fibrils are directed in a circular fashion around the implant and naturally contract, leading to firmer breasts. There were 115 prostheses inserted following subcutaneous mastectomy, and 22 percent developed contracted capsules. Seven implants became exposed because of skin necroses; one was removed because of a Staphylococcus infection; and two patients developed a combination of polyurethane and silicone granulomas. These developed only with the earlier implant, where there was shedding of the polyurethane sponge layer and silicone bled from the low-viscosity silicone used in the earlier implants. No granulomas were noted with the currently used Surgitek Replicon implant. Eighty-five breasts were reconstructed after cancer ablation with polyurethane implants, and the contracture rate was 2.3 percent. Other complications were minimal. A smaller group of patients had augmentation mammaplasty, and 20 prostheses were placed in 10 patients. A 15 percent contracture rate was noted in this group. In this study, 82 percent of patients were followed for up to 14 years. Capsular contractures occurred in 30 implants between 1 and 11 years, for an average recurrence at 6.3 years. The overall contracture rate was 13 percent. Other complications were minimal. All implants were placed subcutaneously or subglandularly, and all were drained.  相似文献   

14.
The objective of this study was to determine whether the type of capsulectomy, anterior or total, affects the recurrence of capsular contracture around subglandular silicone-gel breast implants. A retrospective analysis was performed of patients who underwent either anterior or total capsulectomy for Baker grade 3 or 4 subglandular capsular contracture in our unit. All patients were invited to a review clinic where their capsular status was assessed. There were 100 anterior- disc capsulectomies in 60 patients between 1988 and 1997 and 99 total capsulectomies in 60 patients between 1990 and 1998. The follow-up in the former group was a median of 7 years and mean 6.9 years, compared with median 2.5 and mean 3.1 years in the latter group. Eighty-six percent of the implants removed from both groups at capsulectomy were smooth-walled gel-filled implants. Sixty-nine breasts in the anterior group received textured gel implants at capsulectomy; the remaining 31 received polyurethane-coated Meme implants. In the total capsulectomy group, all but two breasts (one patient) received textured gel implants. After review, the capsular status was known in 80 percent of the anterior and 92 percent of the total capsulectomy group. The review clinic found eight new contractures in five patients to have developed in the anterior compared with none in the total group. Recurrent contractures affected 50 percent of patients (46 percent of breasts) in the anterior and 11 percent of patients (10 percent of breasts) in the total capsulectomy group. Kaplan-Meier survival analysis was applied to the data. By including only patients who received textured gel implants at capsulectomy, the Logrank found a statistical difference between the two treatment groups (0.01 < p < 0.5). We believe that this study provides some evidence that total capsulectomy for subglandular silicone breast implant capsular contracture results in a lower capsular recurrence than anterior- disc capsulectomy. The pattern and risk of recurrence after total capsulectomy and exchange for a modern textured prosthesis appear to approach those following primary augmentation.  相似文献   

15.
BackgroundA large number of clinical studies have reported that the different materials used in breast implants were a possible cause of the different incidence rates of capsular contracture observed in patients after implantation. However, this theory lacks comprehensive support from evidence-based medicine, and considerable controversy remains.ObjectivesIn this study, a cumulative systematic review examined breast augmentation that used implants with textured or smooth surfaces to analyze the effects of these two types of implants on the occurrence of postoperative capsular contracture.MethodsWe conducted a comprehensive search of literature databases, including PubMed and EMBASE, for clinical reports on the incidence of capsular contracture after the implantation of breast prostheses. We performed a cumulative meta-analysis on the incidence of capsular contracture in order from small to large sample sizes and conducted subgroup analyses according to the prosthetic material used, the implant pocket placement, the incision type and the duration of follow-up. Relative risks (RR) and 95% confidence intervals (CI) were used as the final pooled statistics.ResultsThis meta-analysis included 16 randomized controlled trials (RCTs) and two retrospective studies. The cumulative comparison of textured and smooth breast implants showed statistical significance at 2.13 (95% CI, 1.18-3.86) when the fourth study was entered into the analysis. With the inclusion of more reports, the final results indicated that smooth breast implants were more likely to be associated with capsular contracture, with statistical significance at 3.10 (95% CI, 2.23-4.33). In the subgroup analyses, the subgroups based on implant materials included the silicone implant group and the saline implant group, with significant pooled statistical levels of 4.05 (95% CI, 1.97-8.31) and 3.12 (95% CI, 2.19-4.42), respectively. According to implant pocket placement, a subglandular group and a submuscular group were included in the analyses, and only the subglandular group had a statistically significant pooled result of 3.59 (95% CI, 2.43-5.30). Four subgroups were included in the analyses according to incision type: the inframammary incision group, the periareolar incision group, the transaxillary incision group and the mastectomy incision group. Among these groups, only the pooled results of the inframammary and mastectomy incision groups were statistically significant, at 2.82 (95% CI, 1.30-6.11) and 2.30 (95% CI, 1.17-4.50), respectively. Three follow-up duration subgroups were included in the analyses: the one-year group, the two- to three-year group and the ≥five-year group. These subgroups had statistically significant results of 4.67 (95% CI, 2.35-9.28), 3.42 (95% CI, 2.26-5.16) and 2.71 (95% CI, 1.64-4.49), respectively.ConclusionIn mammaplasty, the use of textured implants reduces the incidence of postoperative capsular contracture. Differences in implant pocket placement and incision type are also likely to affect the incidence of capsular contracture; however, this conclusion awaits further study.  相似文献   

16.
The presence of a silicone (poly-dimethyl siloxane) breast prosthesis in a breast reconstruction patient typically leads to fibrous tissue encapsulation of the prosthesis. Fibrous capsular contracture forces the prosthesis into a hardened sphere. The initially satisfactory cosmetic result can thus be changed into a deformed mass of inappropriate compliance. It is the author's hope with the present study to identify a material for implantation with a diminished tendency to form fibrous encapsulation, to improve the long-term results of prosthetic implants. The purpose of this investigation was to compare the early capsule production quality of poly-2-hydroxyethyl methacrylate (PHEMA) and poly-dimethyl siloxane (silicone). Each of five rats subcutaneously underwent implantation with both a disk of poly-dimethyl siloxane (control) and a similar disk of PHEMA. In this study, the extent of fibrous encapsulation was assessed at 6 weeks after implantation of the two disk types. The five disks of poly-dimethyl siloxane were embedded in fibrous tissue, whereas there was no apparent fibrous tissue surrounding the implants of PHEMA. The author concludes that the results for PHEMA were superior to those for silicone at 6 weeks with regard to fibrous encapsulation (p = 0.0312).  相似文献   

17.
Nominally equivalent gel-filled miniprostheses supplied by three different manufacturers were placed subcutaneously in rats under identical conditions in a double-blind comparison. The incidence of experimental contracture, defined by grossly visibly asymmetrical distortion of the implant, was 0, 9, and 91 percent for the different manufacturers, consistent with previous observations. Differences among the different implants with respect to the density of the fibrillar capsule structure, the cellularity, and the amount of extruded gel did not correlate with the incidence of contracture. Contracture rate was inversely proportional to the relative degree of filling of the prostheses, as reflected in deviations from the nominal hemispherical shape, and to the viscosity of the gel filling. For implants of the same type, the incidence of contracture was higher when the prosthesis was underfilled. Contracted capsules were more fibrous and contained more cells with microfilament bundles. It is concluded that the physical and geometric properties of silicone implants are critical in the expression of contracture and that these properties vary significantly among prosthesis manufacturers.  相似文献   

18.
Collis N  Sharpe DT 《Plastic and reconstructive surgery》2000,105(6):1979-85; discussion 1986-9
Concern has been expressed over the long-term integrity of silicone gel breast implants. There are no large series representing experience with these implants outside of the United States. A retrospective case note review of explanted silicone breast implants was performed; 478 implants have been explanted during the past 11 years and relate to the use of these devices since 1971. Loss of implant integrity was not simply related to its age in vivo. Failure was more likely with implants of the late 1970s and early 1980s (second generation) and with subpectoral placement. Implant failure was independent of capsular contracture as the indication for removal (p = 0.09). There is no evidence that the currently used textured silicone gel breast implants are subject to the same loss of integrity as previous examples of these devices. The life span of these implants, the first of which are approaching 10 years in vivo, is at present unknown. Information concerning the integrity of silicone gel breast implants is essential in the current climate for counseling of both new and old implant recipients.  相似文献   

19.
A case of Aspergillus niger fungal colonization associated with bilateral inflatable silicone mammary implants is reported. Painful fibrous capsular contractures without clinical evidence of infection or inflammation characterized the presenting symptoms. Operative findings included a cheesy-white exudate that surrounded the implants and turbid fluid within the implants. All specimens yielded a heavy growth of Aspergillus niger. Special stains of the fibrous capsules were negative for fungal invasion. The etiology and pathogenesis of Aspergillus colonization in this patient are postulated.  相似文献   

20.
Bacterial colonization of mammary implants is a prelude to clinical infection and has been implicated in the etiology of capsular contracture. Antimicrobial impregnation of a variety of medical devices with the combination of minocycline and rifampin has recently emerged as a potentially effective method for preventing device colonization and device-related infection. The objective of this animal study was to examine in vivo the antimicrobial efficacy of minocycline/rifampin-impregnated, saline-filled silicone implants. A rabbit model of Staphylococcus aureus colonization and infection of subcutaneously placed implants was used. A total of 48 saline-filled silicone implants (24 antimicrobe-impregnated and 24 control unimpregnated implants) were suspended in a 106 colony-forming units/ml bacterial suspension of S. aureus for 30 minutes at room temperature, allowed to dry for 60 minutes, and then implanted subcutaneously in the back of 12 rabbits (two antimicrobe-impregnated and two control implants were placed in each rabbit). Rabbits were monitored daily, then killed either at 2 weeks (10 rabbits) or at 4 weeks (two rabbits) and cultured. The antimicrobe-impregnated implants were 12 times less likely to be colonized than control unimpregnated implants (two of 24 versus 23 of 24; p < 0.001), and they were a significantly less likely cause of implant-related infection (0 of 24 versus 22 of 24; p < 0.001) and implant-related abscess (0 of 24 versus 21 of 24; p < 0.001) than control implants. The minocycline/rifampin-impregnated implants routinely demonstrated zones of inhibition against S. aureus at the time of explantation. These results indicate that minocycline/rifampin-impregnated implants can significantly decrease the rate of bacterial colonization, implant-related infection, and implant-related abscess. Antimicrobe-impregnated implants also have the potential of reducing the likelihood of capsular contracture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号