首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
2.
BACKGROUND: Fractionated plasma metanephrine measurements are commonly used in biochemical testing in search of pheochromocytoma. METHODS: We aimed to critically appraise the diagnostic efficacy of fractionated plasma free metanephrine measurements in detecting pheochromocytoma. Nine electronic databases, meeting abstracts, and the Science Citation Index were searched and supplemented with previously unpublished data. Methodologic and reporting quality was independently assessed by two endocrinologists using a checklist developed by the Standards for Reporting of Diagnostic Studies Accuracy Group and data were independently abstracted. RESULTS: Limitations in methodologic quality were noted in all studies. In all subjects (including those with genetic predisposition): the sensitivities for detection of pheochromocytoma were 96%-100% (95% CI ranged from 82% to 100%), whereas the specificities were 85%-100% (95% CI ranged from 78% to 100%). Statistical heterogeneity was noted upon pooling positive likelihood ratios when those with predisposition to disease were included (p < 0.001). However, upon pooling the positive or negative likelihood ratios for patients with sporadic pheochromocytoma (n = 191) or those at risk for sporadic pheochromocytoma (n = 718), no statistical heterogeneity was noted (p = 0.4). For sporadic subjects, the pooled positive likelihood ratio was 5.77 (95% CI = 4.90, 6.81) and the pooled negative likelihood ratio was 0.02 (95% CI = 0.01, 0.07). CONCLUSION: Negative plasma fractionated free metanephrine measurements are effective in ruling out pheochromocytoma. However, a positive test result only moderately increases suspicion of disease, particularly when screening for sporadic pheochromocytoma.  相似文献   

3.
Systematic reviews and meta-analyses are essential to summarize evidence relating to efficacy and safety of health care interventions accurately and reliably. The clarity and transparency of these reports, however, is not optimal. Poor reporting of systematic reviews diminishes their value to clinicians, policy makers, and other users.Since the development of the QUOROM (QUality Of Reporting Of Meta-analysis) Statement—a reporting guideline published in 1999—there have been several conceptual, methodological, and practical advances regarding the conduct and reporting of systematic reviews and meta-analyses. Also, reviews of published systematic reviews have found that key information about these studies is often poorly reported. Realizing these issues, an international group that included experienced authors and methodologists developed PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) as an evolution of the original QUOROM guideline for systematic reviews and meta-analyses of evaluations of health care interventions.The PRISMA Statement consists of a 27-item checklist and a four-phase flow diagram. The checklist includes items deemed essential for transparent reporting of a systematic review. In this Explanation and Elaboration document, we explain the meaning and rationale for each checklist item. For each item, we include an example of good reporting and, where possible, references to relevant empirical studies and methodological literature. The PRISMA Statement, this document, and the associated Web site (http://www.prisma-statement.org/) should be helpful resources to improve reporting of systematic reviews and meta-analyses.  相似文献   

4.
Background: Leptospirosis is a growing public health concern in many tropical and subtropical countries. However, its diagnosis is difficult because of non-specific symptoms and concurrent other endemic febrile diseases. In many regions, the laboratory diagnosis is not available due to a lack of preparedness and simple diagnostic assay or difficult access to reference laboratories. Yet, an early antibiotic treatment is decisive to the outcome. The need for Rapid Diagnostic Tests (RDTs) for bedside diagnosis of leptospirosis has been recognized. We developed a vertical flow immunochromatography strip RDT detecting anti-Leptospira human IgM and evaluated it in patients from New Caledonia, France, and French West Indies. Methodology/Principal Findings: Whole killed Leptospira fainei cells were used as antigen for the test line and purified human IgM as the control line. The mobile phase was made of gold particles conjugated with goat anti-human IgM. Standards for Reporting of Diagnostic Accuracy criteria were used to assess the performance of this RDT. The Microscopic Agglutination Test (MAT) was used as the gold standard with a cut-off titer of ≥400. The sensitivity was 89.8% and the specificity 93.7%. Positive and negative Likelihood Ratios of 14.18 and 0.108 respectively, and a Diagnostic Odds Ratio of 130.737 confirmed its usefulness. This RDT had satisfactory reproducibility, repeatability, thermal tolerance and shelf-life. The comparison with MAT evidenced the earliness of the RDT to detect seroconversion. When compared with other RDT, the Vertical Flow RDT developed displayed good diagnostic performances.

Conclusions/Significance

This RDT might be used as a point of care diagnostic tool in limited resources countries. An evaluation in field conditions and in other epidemiological contexts should be considered to assess its validity over a wider range of serogroups or when facing different endemic pathogens. It might prove useful in endemic contexts or outbreak situations.  相似文献   

5.

Background

The HIV Dementia Scale (HDS) and International HIV Dementia Scale (IHDS) are brief tools that have been developed to screen for and aid diagnosis of HIV-associated dementia (HAD). They are increasingly being used in clinical practice for minor neurocognitive disorder (MND) as well as HAD, despite uncertainty about their accuracy.

Methods and Findings

A systematic review of the accuracy of the HDS and IHDS was conducted. Studies were assessed on Standards for Reporting Diagnostic Accuracy criteria. Pooled sensitivity, specificity, likelihood ratios (LR) and diagnostic odds ratios (DOR) were calculated for each scale as a test for HAD or MND. We retrieved 15 studies of the HDS, 10 of the IHDS, and 1 of both scales. Thirteen studies of the HDS were conducted in North America, and 7 of the IHDS studies were conducted in sub-Saharan Africa. Estimates of accuracy were highly heterogeneous between studies for the HDS but less so for the IHDS. Pooled DOR for the HDS was 7.52 (95% confidence interval 3.75–15.11), sensitivity and specificity for HAD were estimated at 68.1% and 77.9%, and sensitivity and specificity for MND were estimated at 42.0% and 91.2%. Pooled DOR for the IHDS was 3.49 (2.12–5.73), sensitivity and specificity for HAD were 74.3% and 54.7%, and sensitivity and specificity for MND were 64.3% and 66.0%.

Conclusion

Both scales were low in accuracy. The literature is limited by the lack of a gold standard, and variation in estimates of accuracy is likely to be due to differences in reference standard. There is a lack of studies comparing both scales, and they have been studied in different populations, but the IHDS may be less specific than the HDS. These rapid tests are not recommended for diagnostic use, and further research is required to inform their use in asymptomatic screening.  相似文献   

6.
BackgroundPopulation based cancer registration provides a critical role in disease surveillance in terms of incidence, survival, cancer cluster investigations and prevalence trends, and therefore high levels of completeness and timeliness are required. This study estimates completeness and variation between early and late registrations in the N. Ireland Cancer Registry (NICR) and assesses the implications for reporting cancer incidence and for registry-based research.MethodsTwo main approaches assessed completeness. For the period 2010–2012, incidence reported in the first year of data publication was compared to incidence reported in subsequent years until 2015. Demographic characteristics and survival of incident cases ascertained before the first publication year were compared to those ascertained in subsequent years. The flow method approach was used to estimate completeness annually after the incident year.ResultsOverall incidence for all cancers increased between the first year of data publication and subsequent years up to 2015, irrespective of year of diagnosis. Late registrations had poorer survival. The flow method approach estimated the completeness of case ascertainment of NICR data to be 96% complete at five years for all cancers combined.ConclusionThe estimated completeness levels for the NICR are comparable to other high quality cancer registries internationally. While data timeliness has little impact on incidence estimates, delays in registration may have implications for specific research studies into incidence and survival. This means that improvements in the timeliness of reporting should be a target for all registries but not at the expense of completeness.  相似文献   

7.
8.
《Endocrine practice》2023,29(8):644-652
ObjectiveAccurate diagnosis of diabetes insipidus (DI) is of significant importance for correct management. We aimed to evaluate the diagnostic accuracy of copeptin level measurements in the differential diagnosis between DI and primary polydipsia (PP).MethodsA literature search of electronic databases from January 1, 2005, to July 13, 2022, was performed. Primary studies that evaluated the diagnostic accuracy of copeptin concentration in patients with DI and PP were considered eligible. Two reviewers independently screened relevant articles and extracted data. The Quality Assessment of Diagnostic Accuracy Studies 2 tool was used to assess the quality of the included studies. The hierarchical summary receiver operating characteristic model and bivariate method were used.ResultsSeven studies including 422 patients with polydipsia-polyuria syndrome were included; of the 422 patients, 189 (44.79%) presented with arginine vasopressin deficiency (AVP-D, cranial DI) and 212 (50.24%) with PP. The summary estimates of the diagnostic performance of stimulated copeptin to differentiate between PP and AVP-D were 0.93 (95% CI, 0.89-0.97) for sensitivity and 0.96 (95% CI, 0.88-1.00) for specificity. Baseline copeptin level showed high performance in identifying AVP resistance (nephrogenic DI), with a pooled sensitivity of 1.00 (95% CI, 0.82-1.00) and specificity of 1.00 (95% CI, 0.98-1.00); however, it showed little value in the differentiation between PP and AVP-D.ConclusionCopeptin level measurement is a useful tool for the differential diagnosis of patients with DI and PP. Stimulation before copeptin measurement is necessary in the diagnosis of AVP-D.  相似文献   

9.
BackgroundMendelian randomization (MR) analyses have been increasingly used to seek evidence of causal associations. This systematic review aims at characterizing and evaluating the reporting of MR analyses in oncological studies.MethodsThe PubMed database was searched to identify MR cancer studies until December 31, 2017. Two of the authors independently selected and evaluated reporting quality of the studies. Reporting quality in MR studies before 2016 and in 2016/17 was compared.ResultsCancer studies with MR analyses in 2016 and 2017 accounted for 55.8% of the total number of studies identified. In the 77 eligible articles, 39 (50.6%) did not report subjects’ characteristics, 53 (68.8%) did not conduct power estimation, 40 (51.9%) did not state all of the first three MR assumptions (i.e., genetic instrument is associated with exposure, is not associated with confounders, and acts on outcome only through exposure), and 31 (40.3%) did not exclude SNPs that diverged from Hardy-Weinberg equilibrium. More studies estimated power in 2016/2017 than before 2016 (p = 0.028).ConclusionsSome MR cancer studies did not sufficiently report essential information, posing obstacles for critical appraisal. This study proposes for MR analysis a guideline/checklist for future publications in cancer and other biomedical research.  相似文献   

10.
11.

Objective

To assess the accuracy of assessment of eligibility for early medical abortion by community health workers using a simple checklist toolkit.

Design

Diagnostic accuracy study.

Setting

Ethiopia, India and South Africa.

Methods

Two hundred seventeen women in Ethiopia, 258 in India and 236 in South Africa were enrolled into the study. A checklist toolkit to determine eligibility for early medical abortion was validated by comparing results of clinician and community health worker assessment of eligibility using the checklist toolkit with the reference standard exam.

Results

Accuracy was over 90% and the negative likelihood ratio <0.1 at all three sites when used by clinician assessors. Positive likelihood ratios were 4.3 in Ethiopia, 5.8 in India and 6.3 in South Africa. When used by community health workers the overall accuracy of the toolkit was 92% in Ethiopia, 80% in India and 77% in South Africa negative likelihood ratios were 0.08 in Ethiopia, 0.25 in India and 0.22 in South Africa and positive likelihood ratios were 5.9 in Ethiopia and 2.0 in India and South Africa.

Conclusion

The checklist toolkit, as used by clinicians, was excellent at ruling out participants who were not eligible, and moderately effective at ruling in participants who were eligible for medical abortion. Results were promising when used by community health workers particularly in Ethiopia where they had more prior experience with use of diagnostic aids and longer professional training. The checklist toolkit assessments resulted in some participants being wrongly assessed as eligible for medical abortion which is an area of concern. Further research is needed to streamline the components of the tool, explore optimal duration and content of training for community health workers, and test feasibility and acceptability.  相似文献   

12.
《PLoS medicine》2021,18(10)
BackgroundThe importance of infectious disease epidemic forecasting and prediction research is underscored by decades of communicable disease outbreaks, including COVID-19. Unlike other fields of medical research, such as clinical trials and systematic reviews, no reporting guidelines exist for reporting epidemic forecasting and prediction research despite their utility. We therefore developed the EPIFORGE checklist, a guideline for standardized reporting of epidemic forecasting research.Methods and findingsWe developed this checklist using a best-practice process for development of reporting guidelines, involving a Delphi process and broad consultation with an international panel of infectious disease modelers and model end users. The objectives of these guidelines are to improve the consistency, reproducibility, comparability, and quality of epidemic forecasting reporting. The guidelines are not designed to advise scientists on how to perform epidemic forecasting and prediction research, but rather to serve as a standard for reporting critical methodological details of such studies.ConclusionsThese guidelines have been submitted to the EQUATOR network, in addition to hosting by other dedicated webpages to facilitate feedback and journal endorsement.

Simon Pollett and co-workers describe EPIFORGE, a guideline for reporting research on epidemic forecasting.  相似文献   

13.
ObjectiveWe aim to evaluate the accuracy of the 16S ribosomal ribonucleic acid (rRNA) gene polymerase chain reaction (PCR) test in the diagnosis of bloodstream infections through a systematic review and meta-analysis.MethodsA computerized literature search was conducted to identify studies that assessed the diagnostic value of 16S rRNA gene PCR test for bloodstream infections. Study quality was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. We calculated the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and their 95% confidence intervals (95% CI) for each study. Summary receiver operating characteristic (SROC) curve was used to summarize overall test performance. Statistical analysis was performed in Meta-DiSc 1.4 and Stata/SE 12.0 software.ResultsTwenty-eight studies were included in our meta-analysis. Using random-effect model analysis, the pooled sensitivity, specificity, PLR, NLR, and DOR were 0.87 (95% CI, 0.85–0.89), 0.94 (95% CI, 0.93–0.95), 12.65 (95% CI, 8.04–19.90), 0.14 (95% CI, 0.08–0.24), and 116.76 (95% CI, 52.02–262.05), respectively. The SROC curve indicated that the area under the curve (AUC) was 0.9690 and the maximum joint sensitivity and specificity (Q*) was 0.9183. In addition, heterogeneity was statistically significant but was not caused by the threshold effect.ConclusionExisting data suggest that 16S rRNA gene PCR test is a practical tool for the rapid screening of sepsis. Further prospective studies are needed to assess the diagnostic value of PCR amplification and DNA microarray hybridization of 16S rRNA gene in the future.  相似文献   

14.

Background

To allow for correct evaluation of clinical trial results, readers require comprehensive, clear, and highly transparent information on the methodology used and the results obtained. This study aimed to evaluate the quality of reporting in articles on randomized controlled trials (RCTs) of antiretroviral therapy (ART) in the field of HIV/AIDS.

Methods

We searched for original articles on RCTs of ART developed in the field of HIV/AIDS in PubMed database by 5 April 2016. Searched articles were divided into three groups based on the revision year in which the Consolidated Standards of Reporting Trials (CONSORT) guidelines were published: Period 1 (1996–2001); Period 2 (2002–2010); and Period 3 (2011–2016). We evaluated the articles using the reporting rates of the 37 items in the CONSORT 2010 checklist, five items in the protocol deviation, and the three items in the ethics.

Results

Fifty-two articles were extracted and included in this study. Many of the reporting rates calculated using the CONSORT 2010 checklist showed a significantly increasing trend over the successive periods (65% in Period 1, 67% in Period 2, 79% in Period 3; p?<?0.0001). The items with reporting rates?<?50% were “the presence or absence of a protocol change and the reason for such a change,” “randomization and blinding,” and “where the full trial protocol can be accessed.” Reporting rates of deviations were as low as?<?30%, while the reporting rates for patient compliance were the highest (>80% in Period 3) among the five items. The reporting rates for obtaining informed consent and approval by the ethics committee or institutional review board were high (>88%), regardless of the time period assessed.

Conclusion

In terms of representative RCT articles in the field of HIV/AIDS, the reporting rate of the items defined by CONSORT was approximately 70%, improving over the successive CONSORT statement revision periods.
  相似文献   

15.
Routinely collected health data, obtained for administrative and clinical purposes without specific a priori research goals, are increasingly used for research. The rapid evolution and availability of these data have revealed issues not addressed by existing reporting guidelines, such as Strengthening the Reporting of Observational Studies in Epidemiology (STROBE). The REporting of studies Conducted using Observational Routinely collected health Data (RECORD) statement was created to fill these gaps. RECORD was created as an extension to the STROBE statement to address reporting items specific to observational studies using routinely collected health data. RECORD consists of a checklist of 13 items related to the title, abstract, introduction, methods, results, and discussion section of articles, and other information required for inclusion in such research reports. This document contains the checklist and explanatory and elaboration information to enhance the use of the checklist. Examples of good reporting for each RECORD checklist item are also included herein. This document, as well as the accompanying website and message board (http://www.record-statement.org), will enhance the implementation and understanding of RECORD. Through implementation of RECORD, authors, journals editors, and peer reviewers can encourage transparency of research reporting.  相似文献   

16.

Background

Previous studies have reported that natriuretic peptides in the blood and pleural fluid (PF) are effective diagnostic markers for heart failure (HF). These natriuretic peptides include N-terminal pro-brain natriuretic peptide (NT-proBNP), brain natriuretic peptide (BNP), and midregion pro-atrial natriuretic peptide (MR-proANP). This systematic review and meta-analysis evaluates the diagnostic accuracy of blood and PF natriuretic peptides for HF in patients with pleural effusion.

Methods

PubMed and EMBASE databases were searched to identify articles published in English that investigated the diagnostic accuracy of BNP, NT-proBNP, and MR-proANP for HF. The last search was performed on 9 October 2014. The quality of the eligible studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies tool. The diagnostic performance characteristics (sensitivity, specificity, and other measures of accuracy) were pooled and examined using a bivariate model.

Results

In total, 14 studies were included in the meta-analysis, including 12 studies reporting the diagnostic accuracy of PF NT-proBNP and 4 studies evaluating blood NT-proBNP. The summary estimates of PF NT-proBNP for HF had a diagnostic sensitivity of 0.94 (95% confidence interval [CI]: 0.90–0.96), specificity of 0.91 (95% CI: 0.86–0.95), positive likelihood ratio of 10.9 (95% CI: 6.4–18.6), negative likelihood ratio of 0.07 (95% CI: 0.04–0.12), and diagnostic odds ratio of 157 (95% CI: 57–430). The overall sensitivity of blood NT-proBNP for diagnosis of HF was 0.92 (95% CI: 0.86–0.95), with a specificity of 0.88 (95% CI: 0.77–0.94), positive likelihood ratio of 7.8 (95% CI: 3.7–16.3), negative likelihood ratio of 0.10 (95% CI: 0.06–0.16), and diagnostic odds ratio of 81 (95% CI: 27–241). The diagnostic accuracy of PF MR-proANP and blood and PF BNP was not analyzed due to the small number of related studies.

Conclusions

BNP, NT-proBNP, and MR-proANP, either in blood or PF, are effective tools for diagnosis of HF. Additional studies are needed to rigorously evaluate the diagnostic accuracy of PF and blood MR-proANP and BNP for the diagnosis of HF.  相似文献   

17.
18.

Background

Clear, transparent and sufficiently detailed abstracts of randomized trials (RCTs), published in journal articles are important because readers will often base their initial assessment of a trial on such information. However, little is known about the quality of reporting in abstracts of RCTs published in medical journals in China.

Methods

We identified RCTs abstracts from 5 five leading Chinese medical journals published between 1998 and 2007 and indexed in MEDLINE. We assessed the quality of reporting of these abstracts based on the Consolidated Standards of Reporting Trials (CONSORT) abstract checklist. We also sought to identify whether any differences exist in reporting between the Chinese and English language version of the same abstract.

Results

We identified 332 RCT abstracts eligible for examination. Overall, the abstracts we examined reported 0–8 items as designated in the CONSORT checklist. On average, three items were reported per abstract. Details of the interventions (288/332; 87%), the number of participants randomized (216/332; 65%) and study objectives (109/332; 33%) were the top three items reported. Only two RCT abstracts reported details of trial registration, no abstracts reported the method of allocation concealment and only one mentioned specifically who was blinded. In terms of the proportion of RCT abstracts fulfilling a criterion, the absolute difference (percentage points) between the Chinese and English abstracts was 10% (ranging from 0 to 25%) on average, per item.

Conclusions

The quality of reporting in abstracts of RCTs published in Chinese medical journals needs to be improved. We hope that the introduction and endorsement of the CONSORT for Abstracts guidelines by journals reporting RCTs will lead to improvements in the quality of reporting.  相似文献   

19.
In the context of REDD+, Measurement, Reporting and Verification (MRV) is one way to manage forest change information. A national carbon and non-carbon database will be used in REDD+ to negotiate compensation schemes with the international community. Much of this data will be collected at the local level, thus a reporting system that can integrate these locally collected data into the national database is crucial. In this paper we compare and draw lessons from three existing local to national reporting systems that include the participation of local communities: 1) the government extension services, 2) the government owned forestry company, and 3) a private logging company in Indonesia, and provide recommendations for REDD+ reporting systems. The results suggest that the main desired conditions for effective data flow are: benefits to motivate local participation, based on contributions to reporting activities; simple data format and reporting procedures to allow local participation in the reporting process, and to support data aggregation at the national level; a facilitator to mediate data aggregation at the village level to ensure data consistency, completeness and accuracy; and a transparent and clear data flow. Under these conditions, continuous, accountable and consistent data flow from the local level will reach the national level where it can be fully utilized.  相似文献   

20.
Accurate and complete reporting of study methods, results and interpretation are essential components for any scientific process, allowing end-users to evaluate the internal and external validity of a study. When animals are used in research, excellence in reporting is expected as a matter of continued ethical acceptability of animal use in the sciences. Our primary objective was to assess completeness of reporting for a series of studies relevant to mitigation of pain in neonatal piglets undergoing routine management procedures. Our second objective was to illustrate how authors can report the items in the Reporting guidElines For randomized controLled trials for livEstoCk and food safety (REFLECT) statement using examples from the animal welfare science literature. A total of 52 studies from 40 articles were evaluated using a modified REFLECT statement. No single study reported all REFLECT checklist items. Seven studies reported specific objectives with testable hypotheses. Six studies identified primary or secondary outcomes. Randomization and blinding were considered to be partially reported in 21 and 18 studies, respectively. No studies reported the rationale for sample sizes. Several studies failed to report key design features such as units for measurement, means, standard deviations, standard errors for continuous outcomes or comparative characteristics for categorical outcomes expressed as either rates or proportions. In the discipline of animal welfare science, authors, reviewers and editors are encouraged to use available reporting guidelines to ensure that scientific methods and results are adequately described and free of misrepresentations and inaccuracies. Complete and accurate reporting increases the ability to apply the results of studies to the decision-making process and prevent wastage of financial and animal resources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号