首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
PurposeThe purpose of this work is to compare the positioning accuracy achieved by three different imaging techniques and planar vs. CBCT imaging for two common IGRT indications.MethodsA collective of prostate cancer and head-and-neck cancer patients treated at our institution during the year 2013 was retrospectively analyzed. For all treatment fractions (3078 in total), the kind of acquired set-up image and the performed couch shift before treatment were assessed. The distribution of couch corrections was compared for three different imaging systems available at our institution: the treatment beam line operating at 6 MV, a dedicated imaging beam line of nominally 1 MV, and the kVision system at 70–121 kV. Shifts were analyzed for planar and cone-beam CT images. Based on the set-up corrections, CTV to PTV expansion margins were calculated.ResultsThe difference in set-up corrections performed for the three energies and both techniques (planar vs. CBCT) was not significant for head-and-neck cancer patients. For prostate cancer all shifts had equal variance. Averages ranged from −0.7 to +0.7 mm. The set-up margins calculated on the basis of the observed shifts are 4.0 mm (AP) and 3.8 mm (SI, LR) for the head-and-neck PTV and 6.6 mm (SI), 6.7 mm (AP) and 7.9 mm (LR) for the prostate cancer patients.ConclusionsFor three different linac-based imaging energies and planar/CBCT imaging, no relevant differences in set-up shifts were observed. The suggested set-up margins for these indications are of the order of 4 mm for head-and-neck and 6–8 mm for prostate treatment.  相似文献   

2.
PurposeTo compare the planning target volume (PTV) margins needed for prostate patients who have used hydrogel spacer or rectal balloon during proton treatments.MethodTotal of 190 prostate patients treated with proton therapy during 2017 were selected for this study. Of these patients, 96 had hydrogel spacer injection and 94 patients had only rectal balloons insertion. All patients had implanted gold markers inside the prostate for daily target alignment. Post-treatment radigraphs were obtained to evaluate prostate intrafraction motion. The systematic and random components of patient setup residual error and prostate intrafraction motion error were obtained. PTV margins were calculated using the van Herk formula for both patient groups.ResultsFor setup residual error, the mean values in the superior-inferior (SI) direction and the variances in the left–right (LR) direction were statistically different between the two groups. For intrafraction motion, there were significant differences of the mean values in the SI direction and of the variances in both LR and anterior-posterior (AP) directions. The population PTV margins for hydrogel spacer group were 2.6 mm, 3.3 mm, and 1.6 mm in LR, SI, AP directions, respectively. For the rectal balloon group, the PTV margins were 2.1 mm, 3.1 mm, and 2.0 mm in LR, SI, AP directions, respectively.ConclusionStatistically significant differences were observed in the patient setup and prostate intrafraction motion errors of the two patient groups. However, under the current protocol of bladder preparation and daily marker-based x-ray image-guidance, population PTV margins were comparable between the two patient groups.  相似文献   

3.
BackgroundHere we aimed to evaluate the respiratory and cardiac-induced motion of a ICD lead used as surrogate in the heart during stereotactic body radiotherapy (SBRT) of ventricular tachycardia (VT). Data provides insight regarding motion and motion variations during treatment.Materials and methodsWe analyzed the log files of surrogate motion during SBRT of ventricular tachycardia performed in 20 patients. Evaluated parameters included the ICD lead motion amplitudes; intrafraction amplitude variability; correlation error between the ICD lead and external markers; and margin expansion in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions to cover 90% or 95% of all amplitudes.ResultsIn the SI, LL, and AP directions, respectively, the mean motion amplitudes were 5.0 ± 2.6, 3.4. ± 1.9, and 3.1 ± 1.6 mm. The mean intrafraction amplitude variability was 2.6 ± 0.9, 1.9 ± 1.3, and 1.6 ± 0.8 mm in the SI, LL, and AP directions, respectively. The margins required to cover 95% of ICD lead motion amplitudes were 9.5, 6.7, and 5.5 mm in the SI, LL, and AP directions, respectively. The mean correlation error was 2.2 ± 0.9 mm.ConclusionsData from online tracking indicated motion irregularities and correlation errors, necessitating an increased CTV-PTV margin of 3 mm. In 35% of cases, the motion variability exceeded 3 mm in one or more directions. We recommend verifying the correlation between CTV and surrogate individually for every patient, especially for targets with posterobasal localization where we observed the highest difference between the lead and CTV motion.  相似文献   

4.
PurposeTo define optimal planning target volume (PTV) margins for intensity modulated radiotherapy (IMRT) ± knee-heel support (KHS) in patients treated with adjuvant radiotherapy.MethodsComputed tomography (CT) scans ± KHS of 10 patients were taken before and at 3rd and 5th week of treatment, fused and compared with initial IMRT plans.ResultsA PTV margin of 15 mm in anteroposterior (AP) and superoinferior (SI) directions and 5 mm in lateral directions were found to be adequate without any difference between ± KHS except for the SI shifts in CTV-primary at the 3rd week. Five mm margin for iliac CTV was found to be inadequate in 10–20% of patients in SI directions however when 7 mm margin was given for iliac PTV, it was found to be adequate. For presacral CTV, it was found that the most striking shift of the target volume was in the direction of AP. KHS caused significantly less volume of rectum and bladder in the treated volume.ConclusionsPTV margin of 15 mm in SI and AP, and 5 mm in lateral directions for CTV-primary were found to be adequate. A minimum of 7 mm PTV margin should be given to iliac CTV. The remarkable shifting in presacral CTV was believed to be due to the unforeseen hip malposition of obese patients. The KHS seems not to provide additional beneficial effect in decreasing the shifts both in CTV-primary and lymphatic, however it may have a beneficial effect of decreasing the OAR volume in PTV margins.  相似文献   

5.
PurposeTo evaluate the accuracy of an intra-modality trans-abdominal ultrasound (TA-US) device against soft-tissue based Cone-Beam Computed tomography (CBCT) registration for prostate and post-prostatectomy pre-treatment positioning.MethodsThe differences between CBCT and US shifts were calculated on 25 prostate cancer patients (cohort A) and 11 post-prostatectomy patients (cohort B), resulting in 284 and 106 paired shifts for cohorts A and B, respectively. As a second step, a corrective method was applied to the US registration results to decrease the systematic shifts observed between TA-US and CBCT results. This method consisted of subtracting the mean difference obtained between US and CBCT registration results during the first 3 sessions from the US registration results of the subsequent sessions. Inter-operator registration variability (IOV) was also investigated for both modalities.ResultsAfter initial review, about 20% of the US images were excluded because of insufficient quality. The average differences between US and CBCT were: 2.8 ± 4.1 mm, −0.9 ± 4.2 mm, 0.4 ± 3.4 mm for cohort A and 1.3 ± 5.0 mm, −2.3 ± 4.6 mm, 0.5 ± 2.9 mm for cohort B, in the anterior-posterior (AP), superior-inferior (SI) and lateral (LR) directions, respectively. After applying the corrective method, only the differences in the AP direction remained significant (p < 0.05). The IOV values were between 0.6–2.0 mm and 2.1–3.5 mm for the CBCT and TA-US modalities, respectively.ConclusionsBased on the obtained results and on the image quality, the TA-US imaging modality is not safely interchangeable with CBCT for pre-treatment repositioning. Treatment margins adaptation based on the correction of the systematic shifts should be considered.  相似文献   

6.
AimTo use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for 125I prostate implants.BackgroundDose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect.Materials and methodsThe computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose–volume histograms and EUD for the prostate and rectum.ResultsThe mean absorbed doses presented deviations of 3.3–4.0% for the prostate and of 2.3–4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D90 was overestimated by 2.8–3.9% and the rectum D0.1cc resulted in dose differences of 6–8%. The EUD resulted in an overestimation of 3.5–3.7% for the prostate and of 7.7–8.3% for the rectum.ConclusionsThe deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.  相似文献   

7.
PurposeThe aim of this study was to assess the reproducibility of patient shoulder position immobilized with a novel and innovative prototype mask (E-Frame, Engineering System).MethodsThe E-frame mask fixes both shoulders and bisaxillary regions compared with that of a commercial mask (Type-S, CIVCO). Thirteen and twelve patients were immobilized with the Type-S and E-Frame mask systems, respectively. For each treatment fraction, cone-beam CT (CBCT) images of the patient were acquired and retrospectively analyzed. The CBCT images were registered to the planning CT based on the cervical spine, and then the displacements of the acromial extremity of the clavicle were measured.ResultsThe systematic and random errors between the two mask systems were evaluated. The differences of the systematic errors between the two mask systems were not statistically significant. The mean random errors in the three directions (AP, SI and LR) were 2.7 mm, 3.1 mm and 1.5 mm, respectively for the Type-S mask, and 2.8 mm 2.5 mm and 1.4 mm, respectively for the E-Frame mask. The random error of the E-Frame masks in the SI direction was significantly smaller than that of the Type-S. The number of cases showing displacements exceeding 10 mm in the SI direction for at least one fraction was eight (61% of 13 cases) and three (25% of 12 cases) for Type-S and E-Frame masks, respectively.ConclusionsThe E-Frame masks reduced the random displacements of patient’s shoulders in the SI direction, effectively preventing large shoulder shifts that occurred frequently with Type-S masks.  相似文献   

8.
9.
PurposeAn adaptive concomitant boost (ACB) for the neo-adjuvant treatment of rectal cancer was clinically implemented. In this study population margins M(90,90) considering rectal deformation were derived for 10 consecutive patients treated at 18 × 2.3 Gy with Helical Tomotherapy (HT) and prospectively validated on 20 additional patients treated with HT, delivering ACB in the last 6 fractions.MethodsSectorial margins M(90,90) of the whole and second treatment parts were assessed for 90% population through a method combining the 90% coverage probability maps of rectal positions (CPC90%) with 3D local distance measurements between the CPC90% and a reference rectal contour. M(90,90) were compared with the margins M(90,90)95%/99%, ensuring CPC90% coverage with 95%/99% confidence level. M(90,90) of the treatment second part were chosen as ACB margins which were clinically validated for each patient by means of %volume missing of CPC5/6 excluded by the ACB margins.ResultsThe whole treatment M(90,90) ranged between 1.9 mm and 9 mm in the lower-posterior and upper-anterior sectors, respectively. Regarding ACB, M(90,90) were 7 mm in the anterior direction and <5 mm elsewhere. M(90,90)95%/99% did not significantly differ from M(90,90). The %volume excluded by the ACB margin was<2% for all male and <5% for 9/10 female patients. The dosimetry impact on R_adapt for the patients with the largest residual error was negligible.ConclusionsLocal deformation measurements confirm an anisotropic motion of rectum once set-up error is rigidly corrected. Margins of 7 mm anterior and 5 mm elsewhere are adequate for ACB. Female patients show a slightly larger residual error.  相似文献   

10.

Aim/Background

The analysis of systematic and random errors obtained from the pooled data on inter-fraction prostate motion during radiation therapy in two institutions.

Materials and methods

Data of 6085 observations for 216 prostate cancer patients treated on tomotherapy units in two institutions of position correction shifts obtained by co-registration of planning and daily CT studies were investigated. Three independent variables: patient position (supine or prone), target (prostate or prostate bed), and imaging mode (normal or coarse) were analyzed. Systematic and random errors were evaluated and used to calculate the margins for different options of referencing based on the position corrections observed with one, three, or five imaging sessions.

Results

Statistical analysis showed that only the difference between normal and coarse modes of imaging was significant, which allowed to merge the supine and prone position sub-groups as well as the prostate and prostate bed patients. In the normal and coarse imaging groups, the margins calculated using systematic and random errors in the medio-lateral and cranio-caudal directions (5.5 mm and 4.5 mm, respectively) were similar, but significantly different (5.3 mm for the normal mode and 7.1 mm for the coarse mode) in the anterio-posterior direction. The reference scheme based on the first three fractions (R3) was found to be the optimal one.

Conclusions

The R3 reference scheme effectively reduced systematic and random errors. Larger margins in the anterio-posterior direction should be used during prostate treatment on the tomotherapy unit, as coarse imaging mode is chosen in order to reduce imaging time and dose.  相似文献   

11.
PurposeTo analyze the uncertainties of the rectum due to anisotropic shape variations by using a statistical point distribution model (PDM).Materials and methodsThe PDM was applied to the rectum contours that were delineated on planning computed tomography (CT) and cone-beam CT (CBCT) at 80 fractions of 11 patients. The standard deviations (SDs) of systematic and random errors of the shape variations of the whole rectum and the region in which the rectum overlapped with the PTV (ROP regions) were derived from the PDMs at all fractions of each patient. The systematic error was derived by using the PDMs of planning and average rectum surface determined from rectum surfaces at all fractions, while the random error was derived by using a PDM-based covariance matrix at all fractions of each patient.ResultsRegarding whole rectum, the population SDs were larger than 1.0 mm along all directions for random error, and along the anterior, superior, and inferior directions for systematic error. The deviation is largest along the superior and inferior directions for systematic and random errors, respectively. For ROP regions, the population SDs of systematic error were larger than 1.0 mm along the superior and inferior directions. The population SDs of random error for the ROP regions were larger than 1.0 mm except along the right and posterior directions.ConclusionsThe anisotropic shape variations of the rectum, especially in the ROP regions, should be considered when determining a planning risk volume (PRV) margins for the rectum associated with the acute toxicities.  相似文献   

12.
PurposeTo report the commissioning and validation of deformable image registration(DIR) software for adaptive contouring.MethodsDIR (SmartAdapt®v13.6) was validated using two methods namely contour propagation accuracy and landmark tracking, using physical phantoms and clinical images of various disease sites. Five in-house made phantoms with various known deformations and a set of 10 virtual phantoms were used. Displacement in lateral, anterio-posterior (AP) and superior-inferior (SI) direction were evaluated for various organs and compared with the ground truth. Four clinical sites namely, brain (n = 5), HN (n = 9), cervix (n = 18) and prostate (n = 23) were used. Organs were manually delineated by a radiation oncologist, compared with the deformable image registration (DIR) generated contours. 3D slicer v4.5.0.1 was used to analyze Dice Similarity Co-efficient (DSC), shift in centre of mass (COM) and Hausdorff distances Hf95%/avg.ResultsMean (SD) DSC, Hf95% (mm), Hfavg (mm) and COM of all the phantoms 1–5 were 0.84 (0.2) mm, 5.1 (7.4) mm, 1.6 (2.2) mm, and 1.6 (0.2) mm respectively. Phantom-5 had the largest deformation as compared to phantoms 1–4, and hence had suboptimal indices. The virtual phantom resulted in consistent results for all the ROIs investigated. Contours propagated for brain patients were better with a high DSC score (0.91 (0.04)) as compared to other sites (HN: 0.84, prostate: 0.81 and cervix 0.77). A similar trend was seen in other indices too. The accuracy of propagated contours is limited for complex deformations that include large volume and shape change of bladder and rectum respectively. Visual validation of the propagated contours is recommended for clinical implementation.ConclusionThe DIR algorithm was commissioned and validated for adaptive contouring.  相似文献   

13.
PurposeDeep learning has shown great efficacy for semantic segmentation. However, there are difficulties in the collection, labeling and management of medical imaging data, because of ethical complications and the limited number of imaging studies available at a single facility.This study aimed to find a simple and low-cost method to increase the accuracy of deep learning semantic segmentation for radiation therapy of prostate cancer.MethodsIn total, 556 cases with non-contrast CT images for prostate cancer radiation therapy were examined using a two-dimensional U-Net. Initially, all slices were used for the input data. Then, we removed slices of the cranial portions, which were beyond the margins of the bladder and rectum. Finally, the ground truth labels for the bladder and rectum were added as channels to the input for the prostate training dataset.ResultsThe highest mean dice similarity coefficients (DSCs) for each organ in the test dataset of 56 cases were 0.85 ± 0.05, 0.94 ± 0.04 and 0.85 ± 0.07 for the prostate, bladder and rectum, respectively. Removal of the cranial slices from the original images significantly increased the DSC of the rectum from 0.83 ± 0.09 to 0.85 ± 0.07 (p < 0.05). Adding bladder and rectum information to prostate training without removing the slices significantly increased the DSC of the prostate from 0.79 ± 0.05 to 0.85 ± 0.05 (p < 0.05).ConclusionsThese cost-free approaches may be useful for new applications, which may include updated models and datasets. They may be applicable to other organs at risk (OARs) and clinical targets such as elective nodal irradiation.  相似文献   

14.
AimTo assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction.BackgroundImplementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution.Materials and methodsSeventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed.ResultsIn 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively.ConclusionSufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.  相似文献   

15.
PurposeAccurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins.Materials and methodsThe internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors.ResultsThe mean 3D vector at initial set-up was 6.6 ± 2.3 mm, which was significantly reduced to 1.6 ± 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3°. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively.ConclusionsOn-line image guidance with the ITV–CBCT matching technique and automatic 6D correction of the VERO system allowed a very accurate tumor localization in lung SBRT.  相似文献   

16.
Aim and backgroundThe change in the prostate size for radiotherapy has not yet been elucidated. The coverage of radiation dose is affected by changes in the prostate size. We evaluated the changes in the prostate, rectum, and bladder wall sizes during IMRT of fraction 2 Gy/day using MRI.Materials and methodsTwenty-four patients with prostate cancer were enrolled in this study. MRI was performed at three time points. While the initial MRI was performed before the start of radiotherapy (RT), the second MRI was performed at 38 Gy (range: 36–40 Gy), which represented the halfway point of the RT course. The last MRI was performed on the day of completion of the RT course (76 Gy; range: 74–78 Gy). We estimated the prostate, rectum, and bladder wall sizes at three time points.ResultsWe observed no significant difference between the estimated sizes of the prostate during RT in all three phases. In addition, the volume of the rectal wall remained unchanged in all phases. However, the volume of the bladder wall significantly decreased from the initial to the last time points. Furthermore, the standard deviation (SD) obtained by subtracting the final size from the initial one was large (mean, 30.1; SD, 10.1).ConclusionsThe volume of the bladder wall decreased during IMRT. The range of subtraction of the volume of the bladder wall was extensive. Thus, the estimation of the bladder wall may be useful to reduce the inter-fraction variation.  相似文献   

17.
PurposeThe aim of this study was to account for interfractional clinical target volume (CTV) shape variation and apply this to the planning target volume (PTV) margin for prostate cancer radiation treatment plans.MethodsInterfractional CTV shape variations were estimated from weekly cone-beam computed tomography (CBCT) images using statistical point distribution models. The interfractional CTV shape variation was taken into account in the van Herk’s margin formula. The PTV margins without and with the CTV shape variation, i.e., standard (PTVori) and new (PTVshape) margins, were applied to 10 clinical cases that had weekly CBCT images acquired during their treatment sessions. Each patient was replanned for low-, intermediate-, and high-risk CTVs, using both margins. The dose indices (D98 and V70) of treatment plans with the two margins were compared on weekly pseudo-planning computed tomography (PCT) images, which were defined as PCT images registered using a deformable image registration technique with weekly CBCT images, including contours of the CTV, rectum, and bladder.ResultsThe percentage of treatment fractions of patients who received CTV D98 greater than 95% of a prescribed dose increased from 80.3 (PTVori) to 81.8% (PTVshape) for low-risk CTVs, 78.8 (PTVori) to 87.9% (PTVshape) for intermediate-risk CTVs, and 80.3 (PTVori) to 87.9% (PTVshape) for high-risk CTVs. In most cases, the dose indices of the rectum and bladder were acceptable in clinical practice.ConclusionThe results of this study suggest that interfractional CTV shape variations should be taken into account when determining PTV margins to increase CTV coverages.  相似文献   

18.
Background/purposeIntensity-modulated proton therapy is highly sensitive to anatomical variations. A dose restoration method and a full plan adaptation method have been developed earlier, both requiring several parameter settings. This study evaluates the validity of the previously selected settings by systematically comparing them to alternatives.Materials/methodsThe dose restoration method takes a prior plan and uses an energy-adaptation followed by a spot-intensity re-optimization to restore the plan to its initial state. The full adaptation method uses an energy-adaptation followed by the addition of new spots and a spot-intensity optimization to fit the new anatomy. We varied: 1) The margins and robustness settings of the prior plan, 2) the spot-addition sample size, i.e. the number of added spots, 3) the spot-addition stopping criterion, and 4) the spot-intensity optimization approach. The last three were evaluated only for the full plan adaptation. Evaluations were done on 88 CT scans of 11 prostate cancer patients. Dose was prescribed as 55 Gy(RBE) to the lymph nodes and seminal vesicles with a boost to 74 Gy(RBE) to the prostate.ResultsFor the dose restoration method, changing the applied CTV-to-PTV margins and plan robustness in the prior plans yielded insufficient target coverage or increased OAR doses. For the full plan adaptation, more spot-addition iterations and using a different optimization approach resulted in lower OAR doses compared to the default settings while maintaining target coverage. However, the calculation times increased by up to 20 times, making these variations infeasible for online-adaptation.ConclusionWe recommend maintaining the default setting for the dose restoration approach. For the full plan adaptation we recommend to focus on fine-tuning the optimization-parameters, and apart from this using the default settings.  相似文献   

19.
PurposeTo propose a geometrical margin for definition of the vaginal cuff PTV using only CT images of the full bladder (CTfull) in postoperative cervical cancer patients.MethodsTwenty-nine operated cervical cancer patients underwent volumetric arc therapy with a bladder filling protocol. This study assessed bladder filling using a portable bladder scanner and cone-beam computed tomography (CBCT) during the entire treatment period. The measured bladder volumes with a BladderScan® were compared with the delineated volume on CBCT. Titanium clips in the vaginal cuff were analysed to assess geometrical uncertainty and the influence of rectal and bladder volume changes.ResultsBladderScan® showed good agreement with the delineated volume (R = 0.80). The volume changes in the bladder have a greater influence on the clip displacements than in the rectum. The 95th percentile of uncertainty of the clips in reference to CTfull in the right-left (RL), the superoinferior (SI), and the anteroposterior (AP) was 0.32, 0.65, and 1.15 cm, respectively. From this result and intra-fractional movements of the vaginal cuff reported by Haripotepornkul, a new geometrical margin was proposed for definition of the vaginal cuff planning target volume (PTV): 0.5, 0.9, and 1.4 cm in the RL, SI, and AP directions, respectively.ConclusionsA new geometrical margin was proposed for definition of the vaginal cuff PTV based on CTfull, which will be needless of empty bladder at the planning CT scan. This method allows patients to reduce the burden and efficient routine CT scans can be improved.  相似文献   

20.
PurposeFocal Laser ablation therapy is a technique that exposes the prostate tumor to hyperthermia ablation and eradicates cancerous cells. However, due to the excessive heating generated by laser irradiation, there is a possibility of damage to the adjacent healthy tissues. This paper through in silico study presents a novel approach to reduce collateral effects due to heating by the placement of polyethylene glycol (PEG) spacer between the rectum and tumor during laser irradiation. The PEG spacer thickness is optimized to reduce the undesired damage at common laser power used in the clinical trials. Our study also encompasses novelty by conducting the thermal analysis based on the porous structure of prostate tumor.MethodsThe thermal parameters and two thermal phase lags between the temperature gradient and the heat flux, are determined by considering the vascular network of prostate tumor. The Nelder-Mead algorithm is applied to find the minimum thickness of the PEG spacer.ResultsIn the absence of the spacer, the predicted results for the laser power of 4 W, 8 W, and 12 W show that the temperature of the rectum rises up to 58.6 °C, 80.4 °C, and 101.1 °C, while through the insertion of 2.59 mm, 4 mm, and 4.9 mm of the PEG spacer, it dramatically reduces below 42 °C.ConclusionsThe results can be used as a guideline to ablate the prostate tumors while avoiding undesired damage to the rectal wall during laser irradiation, especially for the peripheral zone tumors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号