首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
A sensitive, robust gas chromatographic–mass spectrometric assay suitable for use in pharmacokinetic or bioequivalence studies is presented for the selective serotonin reuptake inhibitor, fluoxetine, and its major metabolite, norfluoxetine (N-desmethylfluoxetine). This method employs solid-phase extraction followed by acetylation with trifluoroacetic anhydride and analysis of the derivatives using selected ion monitoring. The lower limit of quantification was 1.0 ng/ml, and the assay was linear for both analytes from 1 to 100 ng/ml. Mean recoveries following solid-phase extraction at concentrations of 5.0, 20 and 100 ng/ml were 91% (fluoxetine) and 87% (norfluoxetine). Assay precision (as mean RSD) and accuracy (as mean relative error) for both analytes were tested at the same three nominal concentrations and were found to be within 10% in all cases. Analysis of fluoxetine concentrations in plasma samples from 18 volunteers following administration of a single 40 mg dose of fluoxetine provided the following pharmacokinetic data (mean±SD): Cmax, 32.73±9.21 ng/ml; AUC0–∞, 1627±1372 ng/ml h; Tmax, 3.08 h (median); ke, 0.022±0.007 h−1; elimination half-life, 37.69±21.70 h.  相似文献   

2.
Tamoxifen (TAM) is a triphenylethylene anti-oestrogen, commonly used in the treatment of breast cancer. Patients receiving tamoxifen therapy may experience both de novo and acquired resistance. As one of the mechanisms for this may be extensive peripheral bio-transformation of tamoxifen, there has been considerable interest in the pharmacokinetics and metabolism of tamoxifen. A reversed-phase high-performance liquid chromatography separation has been developed to determine the levels of tamoxifen and its major metabolites in human plasma. The method is highly sensitive (2 ng/ml) and selective for tamoxifen, cis-tamoxifen (CIS), 4-hydroxytamoxifen (4-OH) and desmethyltamoxifen (DMT). A μBondapak C18 10 μm column (30 cm × 3.9 mm I.D.) was used, with a mobile phase of methanol-1% triethylamine at pH 8 (89:11, v/v). Sample preparation was carried out using a C2 (500 mg sorbent, 3 ml reservoirs) solid phase extraction method, and extraction efficiencies were approximately 60% for TAM and its metabolites. Accuracy and precision, as determined by spiking plasma samples with a mixture of tamoxifen and its metabolites, ranged from 85–110% (± 5–10%) at 1 μg/ml, 101–118% (± 8–20%) at 0.1 μg/ml and 111–168% (± 43–63%) at 0.01 μg/ml. Results from 59 patients show mean values of 54 ng/ml for 4-OH; 190 ng/ml for DMT; 93 ng/ml for TAM and 30 ng/ml for CIS (detected in three patients only). This methodology can be applied routinely to the determination of TAM and its metabolites in plasma from patients undergoing therapy.  相似文献   

3.
For the determination of cisapride from serum samples, an automated microbore high-performance liquid chromatographic method with column switching has been developed. After serum samples (100 μl) were directly injected onto a Capcell Pak MF Ph-1 pre-column (10×4 mm I.D.), the deproteinization and concentration were carried out by acetonitrile–phosphate buffer (20 mM, pH 7.0) (2:8, v/v) at valve position A. At 2.6 min, the valve was switched to position B and the concentrated analytes were transferred from MF Ph-1 pre-column to a C18 intermediate column (35×2 mm I.D.) using washing solvent. By valve switching to position A at 4.3 min, the analytes were separated on a Capcell Pak C18 UG 120 column (250×1.5 mm I.D.) with acetonitrile–phosphate buffer (20 mM, pH 7.0) (5:5, v/v) at a flow-rate of 0.1 ml/min. Total analysis time per sample was 18 min. The linearity of response was good (r=0.999) over the concentration range of 5–200 ng/ml. The within-day and day-to-day precision (CV) and inaccuracy were less than 3.7% and 3.8%, respectively. The mean recovery was 96.5±2.4% with the detection limit of 2 ng/ml.  相似文献   

4.
A high-performance liquid chromatography (HPLC) method is described for the measurement of the weak alkylating agent CB1954 in human plasma. CB1954 can be used as an innocuous prodrug designed for activation by bacterial nitroreductases in strategies of gene-directed enzyme–prodrug therapy, and becomes activated to a potent bifunctional alkylating agent. The HPLC method involves precipitation and solvent extraction and uses Mitomycin C (MMC) as an internal standard, with a retention time for MMC of 5.85±0.015 min, and for CB1954 of 10.72±0.063 min. The limit of detection for CB1954 is 2.9 ng/ml, and this compares favourably with systems involving direct analysis of plasma (limit of detection 600 ng/ml, approximately). The method is now being used for pharmacokinetic measurements in plasma samples from cancer patients entering phase I clinical trials of CB1954. Results using serial plasma samples from one patient are presented. The patient was treated intravenously with CB1954 (6 mg/m2), and plasma clearance of the drug showed biphasic kinetics with α half-life 14.6 min, and β half-life 170.5 min.  相似文献   

5.
A sensitive, selective, and reproducible GC–MS–SIM method was developed for determination of artemether (ARM) and dihydroartemisinin (DHA) in plasma using artemisinin (ART) as internal standard. Solid phase extraction was performed using C18 Bond Elut cartridges. The analysis was carried out using a HP-5MS 5% phenylmethylsiloxane capillary column. The recoveries of ARM, DHA and ART were 94.9±1.6%, 92.2±4.1% and 81.3±1.2%, respectively. The limit of quantification in plasma was 5 ng/ml (C.V.≤17.4% for ARM and 15.2% for DHA). Calibration curves were linear with R2≥0.988. Within day coefficients of variation were 3–10.4% for ARM and 7.7–14.5% for DHA. Between day coefficients of variations were 6.5–15.4% and 7.6–14.1% for ARM and DHA. The method is currently being used for pharmacokinetic studies. Preliminary data on pharmacokinetics showed Cmax of 245.2 and 35.6 ng/ml reached at 2 and 3 h and AUC0–8h of 2463.6 and 111.8 ngh/ml for ARM and DHA, respectively.  相似文献   

6.
[Arg6, -Trp7,9, mePhe8]-substance P (6–11), code-named antagonist G, is a novel peptide currently undergoing early clinical trials as an anticancer drug. A sensitive, high efficiency high-performance liquid chromatography (HPLC) method is described for the determination in human plasma of antagonist G and its three major metabolites, deamidated-G (M1), G-minus Met11 (M2) and G[Met11(O)] (M3). Gradient elution was employed using 40 mM ammonium acetate in 0.15% trifluoroacetic acid as buffer A and acetonitrile as solvent B, with a linear gradient increasing from 30 to 100% B over 15 min, together with a microbore analytical column (μBondapak C18, 30 cm×2 mm I.D.). Detection was by UV at 280 nm and the column was maintained at 40°C. Retention times varied by <1% throughout the day and were as follows: G, 13.0 min; M1, 12.2 min; M2, 11.2 min; M3, 10.8 min, and 18.1 min for a pyrene conjugate of G (G–P). The limit of detection on column (LOD) was 2.5 ng for antagonist G, M1–3 and G–P and the limit of quantitation (LOQ) was 20 ng/ml for G and 100 ng/ml for M1–3. Sample clean-up by solid-phase extraction using C2-bonded 40 μm silica particles (Bond Elut, 1 ml reservoirs) resulted in elimination of interference from plasma constituents. Within-day and between-day precision and accuracy over a broad range of concentrations (100 ng/ml–100 μg/ml) normally varied by <10%, although at the highest concentrations of M1 and M2 studied (50 μg/ml), increased variability and reduced recovery were observed. The new assay will aid in the clinical development of antagonist G.  相似文献   

7.
Spirals of human saphenous veins (HSV), mounted in a 5 ml organ bath containing Krebs-Henseleit solution (37°C), when kept in contact with defibrotide (100–200 ug/ml) for 15 min, enhance (2 and 3 fold) their own basal release of 6-keto-PGF (61 ± 1.3 pg/mg w.t. n = 12). The phenomenon was long lasting upon repeated washing and sensitive to indomethacin (1 ug/ml). Endothelin-1 (ET-1, 20–40 ng) induced a sustained contraction of HSV and concomitantly released from the venous tissue a proportional amount of 6-keto-PGF.Indomethacin (1 ug/ml), by inhibiting cyclo-oxygenase enzyme, potentiated the contractile activity of ET-1 in HSV whereas exogenous PGE2 (20 ng/ml) considerably reduced the tension developed by the peptide on this venous tissue.Defibrotide (200 ug/ml), by releasing 6-keto-PGF, and other vasoactive prostaglandins, antagonized the contractile effect ET-1 (20 ng) in HSV. This data indicates that the eicosanoid metabolism is involved in the modulation of the potent vasoconstrictor effect of ET-1 in HSV and that PGI2-releaser, such as defibrptide, may have therapeutical value against immoderate changes of venous tone.  相似文献   

8.
Friesian heifers (n = 10) were assigned randomly to receive an intravenous injection of estradiol-17β (E2; 3 mg) or saline: ethanol vehicle solution (6 ml; 1:1) on day 13 of the estrous cycle. Blood was collected collected from the jugular vein by venipuncture into heparinized vacutainer tubes at 30 minute intervals for 2 hours (h) preinjection, 10.5 h postinjection and then at 3 h intervals until estrus. Repeated hormone measurements of 15-keto-13,14-dihydro-PGF (PGFM) and progesterone (P4) were evaluated by split-plot analysis of variance. Mean concentration of PGFM for the 12.5 h acute sampling phase was 164.1 ± .14 pg/ml. A treatment by time interaction was detected (P < .01). After treatment with E2, PGFM concentrations began to increase at approximately 3.5 h, reached a mean peak of 330.4 ± 44.5 pg/ml (n = 5) at 5.5 ± .3 h, and returned to basal concentration by 9.0 ± .6 h. Vehicle treatment did not alter concentrations of PGFM. Injections of E2 on day 13 of the estrous cycle caused luteolysis (P4 concentration < 1 ng/ml) to occur earlier following injection (96.9 ± 10.6 h < 153.6 ±17.7 h; P, 0.05) than did the vehicle control treatment. During the chronic sampling phase of 3 h intervals, 39 of 606 samples (6.4%) were classified as PGFM spikes (323.0 ± 50.0 pg/ml); 21 (53%) of the spikes occurred at a mean interval of 18.9 ± 3.86 h before the time of completed luteolysis. Exogenous E2 induced an acute increase in PGFM that may be indicative of uterine PGF production. Peaks of PGFM in plasma were temporally associated with luteolysis on a within cow basis.  相似文献   

9.
A rapid and simple method was developed for the separation and quantification of the anti nerve agent drug pyridostignmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), its metabolites m-toluamide and m-toluic acid, the insecticide permethrin (3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid(3-phenoxyphenyl)methylester), and two of its metabolites m-phenoxybenzyl alcohol, and m-phenoxybenzoic acid in rat plasma and urine. The method is based on using C18 Sep-Pak® cartridges for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 208 and 230 nm. The compounds were separated using gradient of 1 to 99% acetonitrile in water (pH 3.20) at a flow-rate ranging between 0.5 and 1.7 ml/min in a period of 17 min. The retention times ranged from 5.7 to 14.5 min. The limits of detection were ranged between 20 and 100 ng/ml, while limits of quantitation were 150–200 ng/ml. Average percentage recovery of five spiked plasma samples were 51.4±10.6, 71.1±11.0, 82.3±6.7, 60.4±11.8, 63.6±10.1, 69.3±8.5, 68.3±12.0, 82.6±8.1, and from urine 55.9±9.8, 60.3±7.4, 77.9±9.1, 61.7±13.5, 68.6±8.9, 62.0±9.5, 72.9±9.1, and 72.1±8.0, for pyridostigmine bromide, DEET, permethrin, N-methyl-3-hydroxypyridinium bromide, m-toluamide, m-toluic acid, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 5000 ng/ml. This method was applied to analyze the above chemicals and metabolites following their administration in rats.  相似文献   

10.
An isocratic high-performance liquid chromatographic method has been developed to determine ciprofloxacin levels in chinchilla plasma and middle ear fluid. Ciprofloxacin and the internal standard, difloxacin, were separated on a Keystone ODS column (100 × 2.1 mm I.D., 5 μm Hypersil) using a mobile phase of 30 mM phosphate buffer (pH 3), 20 mM triethylamine, 20 mM sodium dodecyl sulphate—acetonitrile (60:40, v/v). The retention times were 3.0 min for ciprofloxacin and 5.2 min for difloxacin. This fast, efficient protein precipitation procedure together with fluorescence detection allows a quantification limit of 25 ng/ml with a 50 μl sample size. The detection limit is 5 ng/ml with a signal-to-noise ratio of 5:1. Recoveries (mean ± S.D., n = 5) at 100 ng/ml in plasma and middle ear fluid were 89.4 ± 1.2% and 91.4 ± 1.6%, respectively. The method was evaluated with biological samples taken from chinchillas with middle ear infections after administering ciprofloxacin.  相似文献   

11.
Objective: To test for differences in the amount and activity of peritoneal macrophages present in the peritoneal fluid of women with, and without endometriosis using prostaglandin release by macrophages in culture as a marker.Patients: Women of reproductive age undergoing laparoscopy for infertility or chronic pelvic pain with postoperative diagnosis of endometriosis and women undergoing laparoscopy for sterilization.Methods: Peritoneal fluid was aspirated during laparoscopy, volume was recorded, macrophages were isolated via a Ficoll Paque gradient and kept in primary culture. PGE2 and PGF release of the cells were measured before and after stimulation with zymosan.Results: Women with endometriosis had significantly more peritoneal macrophages than controls. Peritoneal macrophages of women with endometriosis released significantly more PGE2 than those of the control group: 8.4 ± 2.0 versus 1.4 ± 0.4 ng/ml/106cells (mean ± SEM, p=0.0005) and PGF : 10 ± 4.3 (endometriosis) versus 1.8 ± 0.4 (control) ng/ml/106cells (mean ± SEM, p = 0.045).Conclusion: There is a significant increase in the amount of prostaglandins released by peritoneal macrophages from women with endometriosis. These prostaglandins might alter uterine and tubal contractility, thereby affecting fertility.  相似文献   

12.
A new HPLC assay method was developed for the simultaneous assay for centpropazine (antidepressant) and its hydroxylated metabolite (II) to assess their pharmacokinetics and metabolism characteristics. Rat serum samples were extracted with ether, backwashed with n-hexane and injected onto the HPLC system, which used a C18 column, gradient elution and fluorescence detection at 250 Ex/350 nm Em. Variations in intra- and inter-batch accuracy and precision were within acceptable limits of <±20% at low and <±15% at higher concentrations. Samples were stable in autosampler prior to injection and after multiple freeze–thaw cycles. Linearity was observed between 0.625 and 20 ng/ml for both I and II in serum. Overall the method developed was highly sensitive and could be employed for a wide range of studies.  相似文献   

13.
The release of prostacyclin from chopped myometrial fractions of 18–20 day pregnant rats was assayed by inhibition of ADP-induced aggregation of citrated rabbit platelet-rich plasma. Preincubation of myometrial tissue with oxytocin 10 mU/ml increased prostacyclin generation from 2.25 ± 0.48 (control) to 3.75 ± 0.73 ng/mg over 15 minutes. Bradykinin 20 μg/ml also caused a significant increase in myometrial prostacyclin output from 2.26 ± 0.19 to 4.26 ± 0.64 ng/mg. PGF 1 μg/ml did not increase prostacyclin release significantly. Pretreatment of myometrial tissue with the phospholipase inhibitor mepacrine significantly reduced the peptide-stimulated release of prostacyclin. The results suggest that prostacyclin production may play an important role in modulating the actions of oxytocin and bradykinin in the pregnant rat myometrium.  相似文献   

14.
A selected-ion monitoring (SIM) determination of serum lycopene, α-carotene and β-carotene by an atmospheric pressure chemical ionization mass spectrometry (APCI–MS) was developed. A large amount of serum cholesterols disturbed the SIM determination of carotenoids by contaminating the segment of interface with the LC–MS. Therefore, separation of carotenoids from the cholesterols was performed using a mixed solution of methanol and acetonitrile (70:30) as the mobile phase on a C18 column of mightsil ODS-5 (75 mm×4.6 mm I.D.). The SIM determination was carried out by introducing only the peak portions of carotenoids and I.S. (squalene) by means of an auto switching valve. In the positive mode of APCI–MS, lycopene, α-carotene and β-carotene were monitored at m/z 537 and I.S. was monitored at m/z 411. This method was linear for all analytes in the range of 15–150 ng for lycopene, 7–70 ng for α-carotene and 25–50 ng for β-carotene. The detection limit of LC–APCI–MS-SIM for carotenoids was about 3 ng per 1 ml of serum (S/N=3). The repeatabilities, expressed as C.V.s, were 10%, 8.4% and 5.3% for lycopene, α-carotene and β-carotene, respectively. The intermediate precisions, expressed as C.V.s, were 11. 2%, 8.8% and 6.5% for lycopene, α-carotene and β-carotene, respectively.  相似文献   

15.
Effects of topical application of 15-HETE on pial arteriolar diameter and cortical perirachnoid cerebrospinal fluid (CSF) prostanoid concentrations were investigated in chloralose-anesthetized newborn pigs. Pial arteriolar diameters were measured using a closed cranial window, and CSF samples from under the window were collected for prostanoid analysis after applying artificial CSF without drug and CSF containing 15-HETE (1, 10, 100, 1000 ng/ml). 15-HETE caused significant dose-related constriction from 162 ± 17.0 μm (control diameter) to 136 ± 14.5 and 129 ± 18.7 μm (100 and 1000 ng/ml, respectively). The concentration of PGE2 (but not of PGF or 6-keto-PGF increased in CSF at 100 and 1000 ng/ml of 15-HETE. Pial arteriolar responses to 15-HETE were determined before and after indomethacin treatment (5 mg/kg, i.v.). 15-HETE (100 ng/ml) constricted pial arterioles before indomethacin (diameter change, −15 ± 10%); after indomethacin, constriction was potentiated in response to the same dose (diameter change, −26 ± 7%). These data support the hypothesis thet, in newborn piglets, 15-HETE exerts a vasoconstrictor effect on pial arterioles, which appears to be attenuated by 15-HETE-induced stimulation of dilator prostanoids.  相似文献   

16.
A rapid and selective high-performance liquid chromatographic assay for simultaneous quantitative determination of a new antifilarial drug (UMF-058, I) and mebendazole (MBZ) is described. After a simple extraction from whole blood, both compounds were analysed using a C18 Nova Pak reversed-phase column and a mobile phase of methanol—0.05 M ammonium dihydrogenphosphate (50:50, v/v) adjusted to pH 4.0, with ultraviolet detection at 291 nm. The average recoveries of I and MBZ over a concentration range of 25–250 ng/ml were 92.0 ± 7.7 and 84.4 ± 4.4%, respectively. The minimum detectable concentrations in whole blood for I and MBZ were 7 and 6 ng/ml, respectively. This method was found to be suitable for pharmacokinetic studies.  相似文献   

17.
A reversed-phase high-performance liquid chromatographic–electrochemical assay was developed and validated for the quantification of olanzapine in human breast milk. The assay involved a solid-phase extraction (SPE) of olanzapine and its internal standard on a Bond Elut Certify LRC mixed-mode cartridge. After conditioning of the SPE cartridge, human milk (1 ml) was passed through the cartridge. The cartridge was washed with five separate washing steps to remove endogenous compounds, and the analytes were eluted with ethyl acetate–ammonium hydroxide (98:2, v/v) solution. The eluate was evaporated to dryness (gentle stream of nitrogen at 40°C), and the residue was dissolved in mobile phase. The extract was injected onto a YMC basic column (150 mm×4.6 mm I.D., 5 μm particle size) at a flow-rate of 1 ml/min. A mixture of 75 mM phosphate buffer, pH 7.0–acetonitrile–methanol (48:26:26, v/v/v) was used as the mobile phase. Standard curves with a lower limit of quantitation of 0.25 ng/ml of olanzapine were linear (r2≥0.9992) over a range of 0.25–100 ng/ml. Based on the analysis of quality control (QC) samples, the average inter-day accuracy (RE) was 99.0% with an average precision (CV) of 6.64% over the entire range. The stability of olanzapine in human milk was established after three freeze–thaw–heat cycles and storage at −70°C for 10 months. The validated method was used to measure olanzapine concentrations in human milk during a clinical trial.  相似文献   

18.
Prostaglandin F (PGF) was measured by immunoassay in plasma and milk of four cows (six experiments). After 30 mg PGF im, plasma PGF peaked at 15 minutes (2.4 ± 0.7 ng/ml) and declined toward basal values by 3 hours; maximum milk PGF (0.91 ± 0.12 ng/ml) occurred at 1 hour. The average excretion rate in milk was 2.9 μg/day 0.9 μg (0.003%) of which was due to the 30 mg PGF injected. In six non-pregnant control cows, daily changes of milk PGF and progesterone were not consistently related.  相似文献   

19.
Infusion of norephinephrine (NE) (1 – 3 μg/ml/min) into the isolated mesenteric vascular preparation of rabbit resulted in a rise in perfusion pressure, which was associated with the release of a prostaglandin E-like substance (PGE) at a concentration of 2.81 ± 0.65 ng/ml in terms of PGE2. Indomethacin (3 μg/ml) abolished the NE-induced release of PGE. Arachidonic acid (0.2 μg/ml) in the presence of indomethacin did not restore the NE-induced release of PGE. Hydrocortisone (10 – 30 μg/ml) and dexamethasone (2 – 5 μg/ml) also inhibited the NE-induced release of PGE. The inhibitory action of both corticosteroids was abolished by arachidonic acid (0.2 μg/ml). Antigen-induced release of a prostaglandin-like substance(PGs) (43.1 ± 3.8 ng/ml in terms of PGE2 and a rabbit aorta contracting substance (RCS) from perfused lungs of sensitized guinea pigs was completely abolished by indomethacin (5 μg/ml) or by hydrocortisone (100 μg/ml). Indomethacin, however, increased histamine release up to 280% of the control level, which was 470 ± 54 ng/ml, while hydrocortisone diminished histamine release down to 30% of the control level. A superimposed infusion of arachidonic acid (1 μg/ml) into the pulmonary artery reversed the hydrocortisone-induced blockade of the release of RCS and PGs. It may be concluded that corticosteroids neither inhibit prostaglandin synthetase nor influence prostaglandin transport through the membranes but they do impair the availability of the substrate for the enzyme.  相似文献   

20.
Infusion of norephinephrine (NE) (1 – 3 μg/ml/min) into the isolated mesenteric vascular preparation of rabbit resulted in a rise in perfusion pressure, which was associated with the release of a prostaglandin E-like substance (PGE) at a concentration of 2.81 ± 0.65 ng/ml in terms of PGE2. Indomethacin (3 μg/ml) abolished the NE-induced release of PGE. Arachidonic acid (0.2 μg/ml) in the presence of indomethacin did not restore the NE-induced release of PGE. Hydrocortisone (10 – 30 μg/ml) and dexamethasone (2 – 5 μg/ml) also inhibited the NE-induced release of PGE. The inhibitory action of both corticosteroids was abolished by arachidonic acid (0.2 μg/ml). Antigen-induced release of a prostaglandin-like substance (PGs) (43.1 ± 3.8 ng/ml in terms of PGE2 and a rabbit aorta contracting substance (RCS) from perfused lungs of sensitized guinea pigs was completely abolished by indomethacin (5 μg/ml) or by hydrocortisone (100 μg/ml). Indomethacin, however, increased histamine release up to 280% of the control level, which was 470 ± 54 ng/ml, while hydrocortisone diminished histamine release down to 30% of the control level. A superimposed infusion of arachidonic acid (1 μg/ml) into the pulmonary artery reversed the hydrocortisone-induced blockade of the release of RCS and PGs. It may be concluded that corticosteroids neither inhibit prostaglandin synthetase nor influence prostaglandin transport through the membranes but they do impair the availability of the substrate for the enzyme.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号