首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
BackgroundAccurate measurement of the tibiotalar alignment is important in radiographic outcome assessment of ankle arthrodesis (AA). In studies, various radiological methods have been used to measure the tibiotalar alignment leading to facultative misinterpretation of results. However, to our knowledge, no previous study has investigated the reliability of tibiotalar alignment measurement in AA. We aimed to investigate the reliability of four different methods of measurement of the frontal and sagittal tibiotalar alignment after AA, and to further clarify the most reliable method for determining the longitudinal axis of the tibia.MethodsThirty-eight weight bearing anterior to posterior and lateral ankle radiographs of thirty-seven patients who had undergone AA with a two screw fixation technique were selected. Three observers measured the frontal tibiotalar angle (FTTA) and the sagittal tibiotalar angle (STTA) using four different methods. The methods differed by the definition of the longitudinal tibial axis. Method A was defined by a line drawn along the lateral tibial border in anterior to posterior radiographs and along the posterior tibial border in lateral radiographs. Method B was defined by a line connecting two points in the middle of the proximal and the distal tibial shaft. Method C was drawn „freestyle”along the longitudinal axis of the tibia, and method D was defined by a line connecting the center of the tibial articular surface and a point in the middle of the proximal tibial shaft. Intra- and interobserver correlation coefficients (ICC) and repeated measurement ANOVA were calculated to assess measurement reliability and accuracy.ResultsAll four methods showed excellent inter- and intraobserver reliability for the FTTA and the STTA. When the longitudinal tibial axis is defined by connecting two points in the middle of the proximal and the distal tibial shaft, the highest interobserver reliability for the FTTA (ICC: 0.980; CI 95%: 0.966–0.989) and for the STTA (ICC: 0.997; CI 95%: 0.996–0.999) is provided. Intergroup analysis for FTTA measurements revealed a statistically significant difference between the method in which the lateral border of the tibia was used to determine the longitudinal axis of the tibia, and the other methods in which the longitudinal axis was defined by bisecting the tibia.ConclusionsWhen the longitudinal axis of the tibia is defined by connecting two points in the middle of the proximal and the distal tibial shaft for measuring the FTTA and STTA, the most favorable interobserver reliability is provided. Therefore, this method can be recommended for evaluating the frontal and the sagittal alignment on anterior to posterior and lateral radiographs after ankle arthrodesis.  相似文献   

2.
Trunk stabilization is achieved differently in patients with low back pain compared to healthy controls. Many methods exist to assess trunk stabilization but not all measure the contributions of intrinsic stiffness and reflexes simultaneously. This may pose a threat to the quality/validity of the study and might lead to misinterpretation of the results. The aim of this study was to provide a critical review of previously published methods for studying trunk stabilization in relation to low back pain (LBP). We primarily aimed to assess their construct validity to which end we defined a theoretical framework operationalized in a set of methodological criteria which would allow to identify the contributions of intrinsic stiffness and reflexes simultaneously. In addition, the clinimetric properties of the methods were evaluated. A total of 133 articles were included from which four main categories of methods were defined; upper limb (un)loading, moving platform, unloading and loading. Fifty of the 133 selected articles complied with all the criteria of the theoretical framework, but only four articles provided information about reliability and/or measurement error of methods to assess trunk stabilization with test–retest reliability ranging from poor (ICC 0) to moderate (ICC 0.72). When aiming to assess trunk stabilization with system identification, we propose a perturbation method where the trunk is studied in isolation, the perturbation is unpredictable, force controlled, directly applied to the upper body, completely known and results in small fluctuations around the working point.  相似文献   

3.
The aim of this study was to examine the intraobserver reliability of a posturographic assessment in patients with low back pain. We investigated 24 symptomatic subjects with defined low back pain (mean: 57.9?years) and a pair-matched control group including 24 asymptomatic persons (mean: 58.1?years). Each participant underwent two measurements on a posturographic device (32?Hz sampling rate) based on the Interactive Balance System (time interval: 7?d). Test procedure consisted of tests on solid ground with eyes open (1) and eyes closed (2). Data analysis included parameters of motor output and a frequency band analysis. Reliability tests were realized using by intraclass correlations (ICC). Coefficients of ICC ranged from 0.36 (95% CI: 0.01–0.73) to 0.94 (95% CI: 0.86–0.97) in both test positions. For 69% (11/16) of the investigated parameters a high level (ICC?>?0.75) of intraobserver reliability was reached. Based on the results, the posturographic measurement system used in this study seems to be appropriate for use in longitudinal study designs in an orthopaedic setting.  相似文献   

4.
BACKGROUND: It is important to evaluate the reliability of common used methods of examining muscle fatigue from the lower back since the methods are used in patient evaluation. METHODS: To establish between-days reliability, ten subjects without lower-back pain performed a Sorensen test, a prone test for back extensor muscles against gravity, on three separate days. EMG was recorded from the L1 and L5 of the back extensor muscles. Fatigue was subjectively rated using a Borg CR-10 scale. Intraclass correlation coefficient, standard error of measurement and coefficient of variation were calculated from a one-way ANOVA. Percent agreement was also calculated. RESULTS: The study revealed good reliability for the slope for the total time (ICC 0.65-0.90), the initial and end median frequency (ICC 0.75-0.89), median frequencies at Borg ratings of three (ICC 0.63-0.88), five (ICC 0.62-0.84) and seven (ICC 0.67-0. 87), endurance time (ICC 0.89). The Borg ratings of the first minute agreed better than those of the second and the third. The Borg ratings at the second and the third test agreed to 40-80%, indicating a need for a practice session. CONCLUSION: The protocol used for assessing fatigue in the back extensor muscles proved to be reliable and is recommended for further use.  相似文献   

5.
The purpose of the present study was to develop a systematic procedure for the establishment of 1 repetition maximum (1RM) in order to describe an easily accessible test procedure that is applicable for physical therapists and athletic trainers who manage strength training for healthy individuals and patients. Another purpose was to investigate the intra- and interrater reliability of 1RM of squat on 1 leg and seated knee extension on 1 leg. Estimates of leg strength and ratings of perceived exertion formed the basis of the amount of load selected. The reliability of the procedure was assessed by a test-retest design. One RM was established for 16 and 27 healthy individuals, for squat and knee extension, respectively. The intrarater reliability of 1RM of squat on 1 leg was questionable (intraclass correlation [ICC] 0.64, measurement error 13.1 kg). The interrater reliability of 1RM of squat on 1 leg was clinically acceptable (ICC 0.94, measurement error 5.2 kg). The intrarater and interrater reliability of 1RM of seated knee extension on 1 leg was clinically acceptable (ICC 0.90, measurement error 5.1 kg and ICC 0.96, measurement error 3.2 kg, respectively). In conclusion, both exercises can be used to determine the load in exercise programs. In addition, seated knee extension may be used to evaluate strength. In contrast, squat on 1 leg is more uncertain to use at assessments between different days, which may be due to the complexity of this exercise. The test, performed in the described manner, is suitable for physical therapists, athletic trainers, and strength and conditioning coaches in clinical practice working with strength training and rehabilitation.  相似文献   

6.
Reliability, the consistency of a test or measurement, is frequently quantified in the movement sciences literature. A common metric is the intraclass correlation coefficient (ICC). In addition, the SEM, which can be calculated from the ICC, is also frequently reported in reliability studies. However, there are several versions of the ICC, and confusion exists in the movement sciences regarding which ICC to use. Further, the utility of the SEM is not fully appreciated. In this review, the basics of classic reliability theory are addressed in the context of choosing and interpreting an ICC. The primary distinction between ICC equations is argued to be one concerning the inclusion (equations 2,1 and 2,k) or exclusion (equations 3,1 and 3,k) of systematic error in the denominator of the ICC equation. Inferential tests of mean differences, which are performed in the process of deriving the necessary variance components for the calculation of ICC values, are useful to determine if systematic error is present. If so, the measurement schedule should be modified (removing trials where learning and/or fatigue effects are present) to remove systematic error, and ICC equations that only consider random error may be safely used. The use of ICC values is discussed in the context of estimating the effects of measurement error on sample size, statistical power, and correlation attenuation. Finally, calculation and application of the SEM are discussed. It is shown how the SEM and its variants can be used to construct confidence intervals for individual scores and to determine the minimal difference needed to be exhibited for one to be confident that a true change in performance of an individual has occurred.  相似文献   

7.

Purpose

To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT).

Methods

We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses.

Results

Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively.

Conclusions

The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement.  相似文献   

8.
Objective: To compare the inter‐rater and intra‐rater reliability and analysis time of two methods for quantifying visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) volumes from magnetic resonance (MR) images. Research Methods and Procedures: Ten subjects (BMI, 27.0 ± 2.1 kg/m2; 56 years of age ± 4 years) underwent MR imaging of the abdomen. Ten transverse T1‐weighted images were selected from each scan and analyzed using two software packages that differ in principle. The first method, ANALYZE version 5.0, represents the manual threshold method, and the second, HIPPO version 1.3, is based on the fuzzy clustering approach. Inter‐rater reliability for each method was assessed by comparing the intra‐class correlation coefficients (ICCs) for VAT and SAT results from two evaluators, and intra‐rater reliability for each method was assessed by comparing ICCs for VAT and SAT analyses performed 1 week apart by the same evaluator. The total time for analysis also was compared between methods. Results: The inter‐rater reliability for VAT was greater with HIPPO than with ANALYZE (ICC = 0.996 vs. 0.828), whereas inter‐rater reliability for SAT did not differ between methods (ICC = 0.975 and 0.987). The intra‐rater reliability was equally high with HIPPO and ANALYZE for both VAT (ICC = 0.998 vs. 0.992) and SAT (ICC = 0.996 vs. 0.992). HIPPO required less than one‐half as much analysis time as ANALYZE (15.9 ± 4.4 vs. 36.5 ± 8.2 minutes, p < 0.0001). Discussion: HIPPO software appears advantageous for the quantification of VAT from multislice MR images because inter‐rater results are more reliable, and it is more time‐efficient than less automated methods.  相似文献   

9.
This study assessed the mechanical reliability and validity of the INRTEK iSAM 9000 isokinetic dynamometer, and compared the obtained torque values of the prototype device with those from a traditional device. Sixty volunteers (40 men and 20 women) were tested at 60 degrees per second for shoulder, knee, and trunk flexion, and extension on both the Cybex 6000 and a new isokinetic dynamometer (iSAM 9000). Intraclass correlation coefficients (ICC) and standard errors of measurement (SEM) revealed a high level of reproducibility and precision in the device's torque measurements (ICC range = 0.94-0.98; SEM range = 5.2-29.7). Pearson r values revealed very high relationships between the two instruments (set 1: r = 0.84-0.93; set 2: r = 0.87-0.93; P < 0.05). Significantly higher peak torque for both sets of left and right knee flexion and extension, right shoulder extension and trunk extension was found for the iSAM 9000 compared to the Cybex 6000 (P < 0.05). The strong ICCs and small SEMs support the device's mechanical reliability and validity. The high correlation coefficients between the prototype dynamometer and the Cybex 6000 support the new device's validity in the measurement of isokinetic torque. The findings of this study will be used to refine the next generation of the INRTEK isokinetic device with respect to test protocols and the reliability of measuring human muscle performance.  相似文献   

10.
Metabolomics is a promising tool for discovery of novel biomarkers of chronic disease risk in prospective epidemiologic studies. We investigated the between- and within-person variation of the concentrations of 163 serum metabolites over a period of 4 months to evaluate the metabolite reliability expressed by the intraclass-correlation coefficient (ICC: the ratio of between-person variance and total variance). The analyses were performed with the BIOCRATES AbsoluteIDQ™ targeted metabolomics technology, including acylcarnitines, amino acids, glycerophospholipids, sphingolipids and hexose in 100 healthy individuals from the European Prospective Investigation into Cancer and Nutrition (EPIC)-Potsdam study who had provided two fasting blood samples 4 months apart. Overall, serum reliability of metabolites over a 4-month period was good. The median ICC of the 163 metabolites was 0.57. The highest ICC was observed for hydroxysphingomyelin C14:1 (ICC = 0.85) and the lowest was found for acylcarnitine C3:1 (ICC = 0). Reliability was high for hexose (ICC = 0.76), sphingolipids (median ICC = 0.66; range: 0.24–0.85), amino acids (median ICC = 0.58; range: 0.41–0.72) and glycerophospholipids (median ICC = 0.58; range: 0.03–0.81). Among acylcarnitines, reliability of short and medium chain saturated compounds was good to excellent (ICC range: 0.50–0.81). Serum reliability was lower for most hydroxyacylcarnitines and monounsaturated acylcarnitines (ICC range: 0.11–0.45 and 0.00–0.63, respectively). For most of the metabolites a single measurement may be sufficient for risk assessment in epidemiologic studies with healthy subjects.  相似文献   

11.
This study evaluated between-session reliability of opto-electronic motion capture to measure trunk posture and three-dimensional ranges of motion (ROM). Nineteen healthy participants aged 24–74 years underwent spine curvature, pelvic tilt and trunk ROM measurements on two separate occasions. Rigid four-marker clusters were attached to the skin overlying seven spinous processes, plus single markers on pelvis landmarks. Rigid body rotations of spine marker clusters were calculated to determine neutral posture and ROM in flexion, extension, total lateral bending (left-right) and total axial rotation (left-right). Segmental spine ROM values were in line with previous reports using opto-electronic motion capture. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated as measures of between-session reliability and measurement error, respectively. Retroreflective markers showed fair to excellent between-session reliability to measure thoracic kyphosis, lumbar lordosis, and pelvic tilt (ICC = 0.82, 0.63, and 0.54, respectively). Thoracic and lumbar segments showed highest reliabilities in total axial rotation (ICC = 0.78) and flexion-extension (ICC = 0.77–0.79) ROM, respectively. Pelvic segment showed highest ICC values in flexion (ICC = 0.78) and total axial rotation (ICC = 0.81) trials. Furthermore, it was estimated that four or fewer repeated trials would provide good reliability for key ROM outcomes, including lumbar flexion, thoracic and lumbar lateral bending, and thoracic axial rotation. This demonstration of reliability is a necessary precursor to quantifying spine kinematics in clinical studies, including assessing changes due to clinical treatment or disease progression.  相似文献   

12.
目的:评价在CT三维重建上测量重度先天性脊柱侧凸Cobb角度的可重复性和可靠性。方法:收集在我院诊治的重度先天性脊柱侧凸病人的CT三维重建和脊柱全长X线片,共计67例。由五名不同测量者对CT三维重建脊柱畸形冠状面主弯Cobb角测量两次,两次间隔在三周以上,并测量脊柱全长X线片脊柱畸形冠状面主弯Cobb角一次,运用组内相关系数分析测量结果之间的可重复性和可靠性。结果:同一测量者两次测量结果之间的差值平均为4.5°。同一测量者两次测量结果之间的组内相关系数为0.969,不同测量者之间测量结果的组内相关系数为0.913。取五名测量者在CT三维重建上第一次测量的Cobb角度,其平均值为(110.5±23.5)°,五名测量者在X线片上测量结果的平均值为(103.1±22.0)°,对两组数据进行Mann-Whitney非参数检验差异有统计学意义(Z=-2.86,P=0.004)。结论:在CT三维重建上测量重度先天性脊柱侧凸的Cobb角,可以减小测量的误差,提高测量的可重复性和可靠性,是一种相对准确的测量方法。  相似文献   

13.
In spite of the growing use of the electrical impedance myography (EIM) measures for clinical assessment and follow-up of diseased muscle tissue, reliability studies are scarce. We evaluate the reliability of the (EIM) technique using four adhesive electrodes over the muscle of interest.Intra- and inter-rater reliability was studied within the same session and between sessions. Thirty-one healthy and volunteer subjects aged between 20 and 26 years were recruited. Phase angle, reactance and resistance were assessed for each EIM measurement. Intraclass correlation coefficient (ICC) was used to determine the relative reliability. Absolute reliability was expressed as the standard error of measurement and the minimum detectable change.Relative reliability within the same session and between sessions for the EIM technique was excellent (ICCs > 0.9) concerning both intra- and inter-rater reliability, except for the component reactance. The absolute reliability was very high for the three EIM components.EIM measures using four adhesive electrodes over the area of interest is a reliable technique to assess muscle tissue status. This study confirms that these measurement results barely vary depending on the examiner and the moment. The present study also confirms phase angle as the least affected EIM component by examiner and evaluation moment.  相似文献   

14.
The aim was to assess the reliability of bulky DNA adducts measurement by means of the 32P-post-labelling assay. The research design consisted of an intramethod reliability study. Buffy coats from 41 subjects were used to obtain two aliquots of 1-5 microg DNA for each subject; bulky DNA adducts were measured using the nuclease P1 32P-post-labelling technique. The reliability of the measurement was assessed by means of the intraclass correlation coefficient (ICC), the distribution of the differences between the two measurements and the limits of agreement. The estimated ICC was 0.977, with a 95% confidence interval between 0.921 and 0.977. The limits of agreement were +/- 0.44 (DNA adducts per 10(8) nucleotides). Only three subjects had differences lying out of such limits. Bulky DNA adduct levels measured by the 32P-post-labelling technique showed good reliability. Only one measurement is needed to use DNA adducts as a biomarker of exposure and, possibly, cancer risk. Besides, as a validation analysis, 32P-post-labelling measurements can be repeated in only 20-30% of samples.  相似文献   

15.
The aim was to assess the reliability of bulky DNA adducts measurement by means of the 32P-post-labelling assay. The research design consisted of an intramethod reliability study. Buffy coats from 41 subjects were used to obtain two aliquots of 1–5 μg DNA for each subject; bulky DNA adducts were measured using the nuclease P1 32P-post-labelling technique. The reliability of the measurement was assessed by means of the intraclass correlation coefficient (ICC), the distribution of the differences between the two measurements and the limits of agreement. The estimated ICC was 0.977, with a 95% confidence interval between 0.921 and 0.977. The limits of agreement were ±0.44 (DNA adducts per 108 nucleotides). Only three subjects had differences lying out of such limits. Bulky DNA adduct levels measured by the 32P-post-labelling technique showed good reliability. Only one measurement is needed to use DNA adducts as a biomarker of exposure and, possibly, cancer risk. Besides, as a validation analysis, 32P-post-labelling measurements can be repeated in only 20–30% of samples.  相似文献   

16.
Sato Y  Kaiba Y  Yamaga E  Minakuchi S 《Gerodontology》2012,29(2):e1033-e1037
doi: 10.1111/j.1741‐2358.2011.00606.x Reliability and validity of a Japanese version of the Oral Health Impact Profile for edentulous subjects Objective: To evaluate the reliability and validity of the Japanese version of the Oral Health Impact Profile for edentulous (OHIP‐EDENT‐J) patients. Background: Oral Health Impact Profile for edentulous is an appropriate instrument for assessing the Quality of life (QOL) in edentulous patients. However, the reliability and validity of the Japanese version had not been evaluated. Methods: The study was conducted on 116 edentulous patients (Group A, requiring new dentures, n = 61; Group B, already having dentures, n = 55). Cronbach’s alpha (α) was used to measure internal consistency of the summary scores for OHIP‐EDENT‐J and various subscales in Groups A and B. The interclass correlation coefficient (ICC) and 95% confidence interval of the summary scores for OHIP‐EDENT‐J and subscales were calculated. The summary scores for OHIP‐EDENT‐J in Groups A and B were compared with evaluate content validity. The Spearman’s correlation coefficient between the summary scores for OHIP‐EDENT‐J and the satisfaction with dentures (100 mm VAS) was calculated for Groups A and B to evaluate concurrent validity. Results: The reliability of the summary scores for OHIP‐EDENT‐J was good (α = 0.93). The ICC of the summary scores for OHIP‐EDENT‐J was 0.85. Summary scores for OHIP‐EDENT‐J were significantly different (p = 0.027) between Group A and Group B, with Group A having the higher value. The Spearman’s correlation coefficient for the degree of satisfaction with dentures and the summary scores for OHIP‐EDENT‐J, calculated for Groups A and B (n = 107), was ?0.609. Conclusion: The OHIP‐EDENT‐J, a questionnaire on oral health–related QOL comprising 19 items, showed good reliability and validity for edentulous patients.  相似文献   

17.
The purpose of this study was to compare the reliability of trunk muscle activity measured by means of surface electromyography (EMG) during maximal and sub-maximal voluntary isometric contractions (MVC/sub-MVC) over repeated trials within-day and between-days in healthy controls and patients with chronic low back pain (CLBP). Eleven volunteers (six controls and five CLBP patients) were assessed twice with a 1-week interval. Surface EMG signals were recorded bilaterally from six trunk muscles. Intra-class correlation coefficients (ICC) and standard error of measurement as a percentage of the grand mean (%SEM) were calculated. MVC and sub-MVC showed excellent within-day reliability in both healthy controls and CLBP patients (ICC mean 0.91; range 0.75-0.98; %SEM mean 4%; range 1-12%). Sub-MVC for both groups between-days showed excellent reliability (ICC mean 0.88; range 0.78-0.97; %SEM mean 7%; range 3-11%). The between-days MVC for both groups showed trends towards lower levels of reliability (ICC mean 0.70; range 0.19-0.99; %SEM mean 17%; range 4-36%) when compared to sub-MVC. Findings of the study provide evidence that sub-MVC are preferable for amplitude normalisation when assessing EMG signals of trunk muscles between-days.  相似文献   

18.
  • Terminal drought substantially reduces chickpea yield. Reducing water use at vegetative stage by reducing transpiration under high vapor pressure deficit (VPD), i.e. under dry/hot conditions, contributes to drought adaptation. We hypothesized that this trait could relate to differences in a genotype's dependence on root water transport pathways and hydraulics.
  • Transpiration rate responses in conservative and profligate chickpea genotypes were evaluated under increasing VPD in the presence/absence of apoplastic and cell‐to‐cell transport inhibitors.
  • Conservative genotypes ICC 4958 and ICC 8058 restricted transpiration under high VPD compared to the profligate genotypes ICC 14799 and ICC 867. Profligate genotypes were more affected by aquaporin inhibition of the cell‐to‐cell pathway than conservative genotypes, as measured by the root hydraulic conductance and transpiration under high VPD. Aquaporin inhibitor treatment also led to a larger reduction in root hydraulic conductivity in profligate than in conservative genotypes. In contrast, blockage of the apoplastic pathway in roots decreased transpiration more in conservative than in profligate genotypes. Interestingly, conservative genotypes had high early vigour, whereas profligate genotypes had low early vigour.
  • In conclusion, profligate genotypes depend more on the cell‐to‐cell pathway, which might explain their higher root hydraulic conductivity, whereas water‐saving by restricting transpiration led to higher dependence on the apoplastic pathway. This opens the possibility to screen for conservative or profligate chickpea phenotypes using inhibitors, itself opening to the search of the genetic basis of these differences.
  相似文献   

19.
The purpose of this study was to examine the reliability of normalisation methods used in the study of the posterior and posterolateral neck muscles in a group of healthy controls. Six asymptomatic male subjects performed a total of 12 maximum voluntary isometric contractions (MVIC) and 60%-submaximal isometric contractions (60%-MVIC) against the torque arm of an isokinetic dynamometer whilst surface and intramuscular electromyography (EMG) was recorded unilaterally from representative posterior and posterolateral locations. Reliability was calculated using intra-class correlation coefficient (ICC), relative standard error of measurement (%SEM) and relative coefficient of variation (%CV). Maximal torque output was found to be highly reliable in the directions of extension and right lateral bending when the first of three MVIC contractions was excluded. When averaged across contraction direction, high reliability was found for both surface (MVIC: ICC=0.986, %SEM=7.5, %CV=9.2; 60%-MVIC: ICC=0.975, %SEM=10, %CV=13.7) and intramuscular (MVIC: ICC=0.910, %SEM=20, %CV=19.1; 60%-MVIC: ICC=0.952, %SEM=16.5, %CV=13.5) electrodes. Intramuscular electrodes displayed the least reliability in right lateral bending. The use of visual feedback markedly increased the reliability of 60%-MVIC contractions.  相似文献   

20.
The aim was to evaluate the reliability of a method of measuring neck muscle fatigue among helicopter pilots. METHOD: Surface EMG from three areas in the neck region, bilaterally, was recorded among 10 male helicopter pilots while they were performing isometric contractions in flexion and extension for 45 s, sustaining a force representing 75% of maximum strength in a seated position. Perceived fatigue was rated using the Borg CR-10 scale. The test was repeated twice the first day and then two additional times with one-week intervals. Variables analyzed were the slope of the median frequency change, the normalized slope, and the ratings after 15, 30 and 45 s; and also the initial median frequency (IMDF). The intra-class correlation (ICC) and the measurement error (S(w)), intra- and inter-day were calculated statistically. RESULTS: The best reliability for the slope was found for the 45 s intra-day analysis taking all measurements into account (ICC 0.65-0.83). The reliability after 30 s was poorer but still acceptable (ICC 0.52-0.71). For the subjective ratings, the highest reliability was found after 30 s inter-day (ICC 0.86-0.88). IMDF showed generally high reliability for the intra-day analyses (ICC 0.63-0.80). CONCLUSION: The method is reliable for use in further research. Since performing a contraction of 75% of maximum was quite strenuous, we recommend that the protocol be shortened to 30 s.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏