首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A method (denoted SISCAPA) for quantitation of peptides in complex digests is described. In the method, anti-peptide antibodies immobilized on 100 nanoliter nanoaffinity columns are used to enrich specific peptides along with spiked stable-isotope-labeled internal standards of the same sequence. Upon elution from the anti-peptide antibody supports, electrospray mass spectrometry is used to quantitate the peptides (natural and labeled). In a series of pilot experiments, tryptic test peptides were chosen for four proteins of human plasma (hemopexin, alpha1 antichymotrypsin, interleukin-6, and tumor necrosis factor-alpha) from a pool of 10,203 in silico tryptic peptide candidates representing 237 known plasma components. Rabbit polyclonal antibodies raised against the chosen peptide sequences were affinity purified and covalently immobilized on POROS supports. Binding and elution from these supports was shown to provide an average 120-fold enrichment of the antigen peptide relative to others, as measured by selected ion monitoring (SIM) or selected reaction monitoring (SRM) electrospray mass spectrometry. The columns could be recycled with little loss in binding capacity, and generated peptide ion current measurements with cycle-to-cycle coefficients of variation near 5%. Anti-peptide antibody enrichment will contribute to increased sensitivity of MS-based assays, particularly for lower abundance proteins in plasma, and may ultimately allow substitution of a rapid bind/elute process for the time-consuming reverse phase separation now used as a prelude to online MS peptide assays. The method appears suitable for rapid generation of assays for defined proteins, and should find application in the validation of diagnostic protein panels in large sample sets.  相似文献   

2.
Biomarker discovery produces lists of candidate markers whose presence and level must be subsequently verified in serum or plasma. Verification represents a paradigm shift from unbiased discovery approaches to targeted, hypothesis-driven methods and relies upon specific, quantitative assays optimized for the selective detection of target proteins. Many protein biomarkers of clinical currency are present at or below the nanogram/milliliter range in plasma and have been inaccessible to date by MS-based methods. Using multiple reaction monitoring coupled with stable isotope dilution mass spectrometry, we describe here the development of quantitative, multiplexed assays for six proteins in plasma that achieve limits of quantitation in the 1-10 ng/ml range with percent coefficients of variation from 3 to 15% without immunoaffinity enrichment of either proteins or peptides. Sample processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate biomarker proteins were developed and optimized by addition of exogenous proteins to immunoaffinity depleted plasma from a healthy donor. Quantitative multiple reaction monitoring assays were designed and optimized for signature peptides derived from the test proteins. Based upon calibration curves using known concentrations of spiked protein in plasma, we determined that each target protein had at least one signature peptide with a limit of quantitation in the 1-10 ng/ml range and linearity typically over 2 orders of magnitude in the measurement range of interest. Limits of detection were frequently in the high picogram/milliliter range. These levels of assay performance represent up to a 1000-fold improvement compared with direct analysis of proteins in plasma by MS and were achieved by simple, robust sample processing involving abundant protein depletion and minimal fractionation by strong cation exchange chromatography at the peptide level prior to LC-multiple reaction monitoring/MS. The methods presented here provide a solid basis for developing quantitative MS-based assays of low level proteins in blood.  相似文献   

3.
A multiple reaction monitoring liquid chromatography method with tandem mass spectrometric detection for quantitation of Staphylococcus aureus via phage amplification detection is described. This phage amplification detection method enables rapid and accurate quantitation of viable S. aureus by detecting an amplified capsid protein from a specific phage. A known amount of metabolically labeled (15)N reference bacteriophage, utilized as the input phage and as the internal standard for quantitation, was spiked into S. aureus samples. Following a 2-h incubation, the sample was subjected to a 3-min rapid trypsin digest and analyzed by high-throughput liquid chromatography tandem mass spectrometric detection targeting peptides unique to both the (15)N (input phage) and (14)N (progeny phage) capsid proteins. Quantitation was achieved by comparing peak areas of target peptides from the metabolically labeled (15)N bacteriophage peptide internal standard with that of the wild-type (14)N peptides that were produced by phage amplification and subsequent digestion when the host bacteria was present. This approach is based on the fact that a labeled species differs from the unlabeled one in terms of its mass but exhibits almost identical chemical properties such as ion yields and retention times. A 6-point calibration curve for S. aureus concentration was constructed with standards ranging from 5.0 × 10(4) colony forming units (CFU) ml(-1) to 2.0 × 10(6) CFU ml(-1), with the (15)N reference phage spiked at a concentration of 1.0 × 10(9) plaque forming units (PFU) ml(-1). Amplification with (15)N bacteriophage coupled with LC-MS/MS detection offers speed (3 h total analysis time), sensitivity (LOD: < 5.0 × 10(4) CFU ml(-1)), accuracy, and precision for quantitation of S. aureus.  相似文献   

4.
There is a great need for quantitative assays in measuring proteins. Traditional sandwich immunoassays, largely considered the gold standard in quantitation, are associated with a high cost, long lead time, and are fraught with drawbacks (e.g. heterophilic antibodies, autoantibody interference, ''hook-effect'').1 An alternative technique is affinity enrichment of peptides coupled with quantitative mass spectrometry, commonly referred to as SISCAPA (Stable Isotope Standards and Capture by Anti-Peptide Antibodies).2 In this technique, affinity enrichment of peptides with stable isotope dilution and detection by selected/multiple reaction monitoring mass spectrometry (SRM/MRM-MS) provides quantitative measurement of peptides as surrogates for their respective proteins. SRM/MRM-MS is well established for accurate quantitation of small molecules 3, 4 and more recently has been adapted to measure the concentrations of proteins in plasma and cell lysates.5-7 To achieve quantitation of proteins, these larger molecules are digested to component peptides using an enzyme such as trypsin. One or more selected peptides whose sequence is unique to the target protein in that species (i.e. "proteotypic" peptides) are then enriched from the sample using anti-peptide antibodies and measured as quantitative stoichiometric surrogates for protein concentration in the sample. Hence, coupled to stable isotope dilution (SID) methods (i.e. a spiked-in stable isotope labeled peptide standard), SRM/MRM can be used to measure concentrations of proteotypic peptides as surrogates for quantification of proteins in complex biological matrices. The assays have several advantages compared to traditional immunoassays. The reagents are relatively less expensive to generate, the specificity for the analyte is excellent, the assays can be highly multiplexed, enrichment can be performed from neat plasma (no depletion required), and the technique is amenable to a wide array of proteins or modifications of interest.8-13 In this video we demonstrate the basic protocol as adapted to a magnetic bead platform.  相似文献   

5.
Given the extensive efforts applied toward proteomics and research in biomarkers, methods for the simultaneous measurement of proteins, peptides, metabolic intermediates, hormones, etc. in a complex sample may be required in the foreseeable future. Assays based on mass spectrometric detection may be suitable for meeting the demands of such complex samples with sensitivity and specificity. An analytical method for the quantitation of C-reactive protein (CRP), a well-known marker of inflammation, is described. Exact quantities of two synthetic (13)C-labeled CRP tryptic peptides were added as internal standards directly to the sample prior to chemical treatment, trypsinization, and liquid chromatography/mass spectrometry quantitation. C-reactive protein levels based on isotopic response ratios were measured. Intact C-reactive protein was spiked into blank rat urine for chemical and enzymatic treatment, producing linear response ratios of labeled to unlabeled peptides. For rigorous quantitation, standard curves, and quality control samples were prepared in rat urine with highly purified labeled and unlabeled peptides over the 50 pg-5 ng/muL concentration range. Using the same chemical and enzymatic treatment used for digestion of intact CRP, data from these samples demonstrated excellent analytical performance. The method was successfully applied toward the quantitation of urinary C-reactive protein from a study of drug-induced nephrotoxicity.  相似文献   

6.
Biomarker discovery results in the creation of candidate lists of potential markers that must be subsequently verified in plasma.1 The most mature methods at present require abundant protein depletion and fractionation at the protein/peptide levels in order to detect and quantitate low ng/mL concentrations of plasma proteins by stable isotope dilution mass spectrometry. Sample-processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate bio-marker proteins were evaluated by adding five non-native proteins to immunoaffinity-depleted female plasma at varying concentrations (1000, 100, 50, 25, and 10 ng/mL). Each protein was monitored by one or more representative synthetic tryptic peptides labeled with [13C6]leucine or [13C5] valine. Following reduction, carbamidomethylation, and enzymatic digestion, two separate processing paths were compared. In path 1, digested plasma was diluted 1:10 and [13C] internal standards were added just prior to direct analysis by multiple reaction monitoring with LC-MS/MS (MRM LC-MS/MS). In path 2, peptides were separated by strong cation exchange, and [13C] internal standards were added to corresponding SCX fractions prior to analysis by MRM LC-MS/MS. Detection and quantitation by MRM used the response of at least two product ions from each of the signature peptides. Using processing path 1, we achieved detection and quantitation down to 50 ng/mL in depleted plasma. However, using processing path 2, we achieved detection and quantitation of all spiked proteins, including the non-native protein at 10 ng/mL. While analysis of non-fractionated plasma achieved higher recovery of those proteins detected in both processes, SCX fractionation at the peptide level clearly increases detection and LOQs for potential biomarker proteins in plasma.  相似文献   

7.
A method has been developed, called the mass western experiment in analogy to the Western blot, to detect the presence of specific proteins in complex mixtures without the need for antibodies. Proteins are identified with high sensitivity and selectivity, and their abundances are compared between samples. Membrane protein extracts were labeled with custom isotope-coded affinity tag reagents and digested, and the labeled peptides were analyzed by liquid chromatography-tandem mass spectrometry. Ions corresponding to anticipated tryptic peptides from the proteins of interest were continuously subjected to collision-induced dissociation in an ion trap mass spectrometer; heavy and light isotope-coded affinity tag-labeled peptides were simultaneously trapped and fragmented accomplishing identification and quantitation in a single mass spectrum. This application of ion trap selective reaction monitoring maximizes sensitivity, enabling analysis of peptides that would otherwise go undetected. The cell surface proteins prostate stem cell antigen (PSCA) and ErbB2 were detected in prostate and breast tumor cell lines in which they are expressed in known abundances spanning orders of magnitude.  相似文献   

8.
液质联用多反应监测法定量目标多肽或蛋白质   总被引:2,自引:0,他引:2  
为建立优化的血浆内源性多肽提取方法,并且构建目标多肽和蛋白质的质谱定量方 法,本研究考察了超滤法、有机溶剂沉淀法和固相萃取法对血浆内源性多肽的提取效果 ,并通过Tricine-SDS-PAGE对提取效果进行比较.通过液相色谱串联质谱多反应监测 (MRM)分析,建立了多肽标准品ESAT-6定量方法,并将ESAT-6定量建立的液相色谱和质谱条件应用于蛋白质的定量,对多肽和蛋白质MRM定量的标准曲线进行了考 察.Tricine-SDS-PAGE结果表明,乙腈沉淀法是最佳的血浆内源性多肽提取方法,低分子量的多肽可以得到很好的富集,且能有效地去除高分子蛋白质的污染.液相色谱串联 质谱MRM法检测血浆内提取的多肽,标准曲线的线性较好,相关系数为0.999.另外,采 用MRM法对胶内分离的蛋白质进行定量,标准曲线的线性相关系数为0.995.综上所述, 本研究构建了一种简单有效的血浆多肽提取方法,通过液质联用MRM法成功地实现了目标多肽和蛋白质定量测定.该定量方法可以推广应用于复杂样品中的多肽和蛋白质的定 量分析.  相似文献   

9.
We describe a simple protocol for identifying and quantifying the two components in binary mixtures of species possessing one or more similar proteins. Central to the method is the identification of ''corresponding proteins'' in the species of interest, in other words proteins that are nominally the same but possess species-specific sequence differences. When subject to proteolysis, corresponding proteins will give rise to some peptides which are likewise similar but with species-specific variants. These are ''corresponding peptides''. Species-specific peptides can be used as markers for species determination, while pairs of corresponding peptides permit relative quantitation of two species in a mixture. The peptides are detected using multiple reaction monitoring (MRM) mass spectrometry, a highly specific technique that enables peptide-based species determination even in complex systems. In addition, the ratio of MRM peak areas deriving from corresponding peptides supports relative quantitation. Since corresponding proteins and peptides will, in the main, behave similarly in both processing and in experimental extraction and sample preparation, the relative quantitation should remain comparatively robust. In addition, this approach does not need the standards and calibrations required by absolute quantitation methods. The protocol is described in the context of red meats, which have convenient corresponding proteins in the form of their respective myoglobins. This application is relevant to food fraud detection: the method can detect 1% weight for weight of horse meat in beef. The corresponding protein, corresponding peptide (CPCP) relative quantitation using MRM peak area ratios gives good estimates of the weight for weight composition of a horse plus beef mixture.  相似文献   

10.
Plasma is recognized as a promising source of disease-related biomarkers, and proteomic approaches for identifying novel plasma biomarkers are in great demand. However, the complexity and dynamic protein concentration range of plasma remain the main obstacles for current research in this field. In this study, plasma proteins were prefractioned by immunodepletion and Protein Equalizer Technology to remove high abundant proteins, then labeled with an 8-plex isobaric tags for relative and absolute quantitation (iTRAQ) to improve the peptide ionization, and analyzed by strong-cation-exchange(SCX) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Our results showed that both prefraction methods were complementary, with regard to the number of identified proteins. Good chromatographic technique is important to further fractionate the iTRAQ labeling peptides, which allowed 320 and 248 different proteins to be characterized from two prefraction methods, respectively, encompassing a wide array of biological functions and a broad dynamic range of 107. Furthermore, the accuracy of iTRAQ relative quantitation for differentially expressed proteins is associated with the number of peptides hits per protein.  相似文献   

11.
Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled with 13C6-arginine and 13C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method was robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high resolution.Key words: protein therapeutics, monoclonal antibodies, comparability, peptide mapping, mass spectrometry, LC-MS, stable isotope-tagged reference standard, SITRS  相似文献   

12.
Selected reaction monitoring, also known as multiple reaction monitoring, is a powerful targeted mass spectrometry approach for a confident quantitation of proteins/peptides in complex biological samples. In recent years, its optimization and application have become pivotal and of great interest in clinical research to derive useful outcomes for patient care. Thus, selected reaction monitoring/multiple reaction monitoring is now used as a highly sensitive and selective method for the evaluation of protein abundances and biomarker verification with potential applications in medical screening. This review describes technical aspects for the development of a robust multiplex assay and discussing its recent applications in cardiovascular proteomics: verification of promising disease candidates to select only the highest quality peptides/proteins for a preclinical validation, as well as quantitation of protein isoforms and post-translational modifications.  相似文献   

13.
Selected reaction monitoring (SRM) is a mass spectrometry method with documented ability to quantify proteins accurately and reproducibly using labeled reference peptides. However, the use of labeled reference peptides becomes impractical if large numbers of peptides are targeted and when high flexibility is desired when selecting peptides. We have developed a label-free quantitative SRM workflow that relies on a new automated algorithm, Anubis, for accurate peak detection. Anubis efficiently removes interfering signals from contaminating peptides to estimate the true signal of the targeted peptides. We evaluated the algorithm on a published multisite data set and achieved results in line with manual data analysis. In complex peptide mixtures from whole proteome digests of Streptococcus pyogenes we achieved a technical variability across the entire proteome abundance range of 6.5-19.2%, which was considerably below the total variation across biological samples. Our results show that the label-free SRM workflow with automated data analysis is feasible for large-scale biological studies, opening up new possibilities for quantitative proteomics and systems biology.  相似文献   

14.
Quantitation of relative or absolute amounts of proteins by mass spectrometry can be prone to large errors. The use of MS/MS ion intensities and stable isotope labeling, which we term stable isotope labeling tandem mass spectrometry (SILT), decreases the effects of contamination from unrelated compounds. We present a software package (SILTmass) that automates protein identification and quantification by the SILT method. SILTmass has the ability to analyze the kinetics of protein turnover, in addition to relative and absolute protein quantitation. Instead of extracting chromatograms to find elution peaks, SILTmass uses only scans in which a peptide is identified and that meet an ion intensity threshold. Using only scans with identified peptides, the accuracy and precision of SILT is shown to be superior to precursor ion intensities, particularly at high or low dilutions of the isotope labeled compounds or with low amounts of protein. Using example scans, we demonstrate likely reasons for the improvements in quantitation by SILT. The appropriate use of variable modifications in peptide identification is described for measurement of protein turnover kinetics. The combination of identification with SILT facilitates quantitation without peak detection and helps to ensure the appropriate use of variable modifications for kinetics experiments.  相似文献   

15.
The human U1 snRNP (small nuclear ribonucleoprotein), which is a part of the spliceosome, consists of U1 snRNA and ten different proteins: seven Sm proteins B/B', D1, D2, D3, E, F, and G and the three U1-specific proteins U1-70 K, U1-A, U1-C. To determine the stoichiometry of all ten proteins, the complex was denatured, digested completely with an endoproteinase and labeled with an amine-specific tag. Corresponding peptides were synthesized and labeled with the same tag containing heavier isotopes. The digest was then spiked with defined amounts of the synthetic peptides, and the resulting isotopic peptide pairs were analyzed quantitatively by mass spectrometry. The mass spectra provided information about the absolute amount of each component in the starting protein mixture. The use of the isotope-coded, amine-specific reagents propionyl-N-oxysuccinimide and nicotinoyl-N-oxysuccinimide was evaluated for stoichiometry determination; the nicotinoyl reagent was found to be advantageous because of its greater mass spectrometric sensitivity. Absolute quantities of all ten proteins were measured, showing equal numbers of all ten proteins in the U1 spliceosomal snRNP. These data demonstrate that quantitative mass spectrometry has great potential for the determination of the stoichiometry of multiprotein complexes.  相似文献   

16.
For relative protein quantitation by mass spectrometry we metabolically labeled E. coli bacteria with 15N-enriched diets. Proteins extracted from 15N-labeled and unlabeled E. coli bacteria were mixed, separated by two-dimensional gel electrophoresis and enzymatically digested. The resulting tryptic peptides were analyzed by MALDI mass spectrometry. For the relative protein quantitation we developed fully automated software, QuantiSpec (Quantitative Mass Spectrometry Analysis Software), which uses data from MALDI TOF mass spectrometry and the Mascot database search engine. QuantiSpec detects natural as well as partially or fully labeled peptide isotope distributions. For each identified peptide the 15N incorporation rate is determined by comparing the experimental to a set of theoretical isotope patterns based on the peptide sequence. Relative quantitation is accomplished by calculating the signal intensity ratios for each 14N/15N peptide pair.  相似文献   

17.
《Journal of Proteomics》2008,71(6):601-608
For relative protein quantitation by mass spectrometry we metabolically labeled E. coli bacteria with 15N-enriched diets. Proteins extracted from 15N-labeled and unlabeled E. coli bacteria were mixed, separated by two-dimensional gel electrophoresis and enzymatically digested. The resulting tryptic peptides were analyzed by MALDI mass spectrometry. For the relative protein quantitation we developed fully automated software, QuantiSpec (Quantitative Mass Spectrometry Analysis Software), which uses data from MALDI TOF mass spectrometry and the Mascot database search engine. QuantiSpec detects natural as well as partially or fully labeled peptide isotope distributions. For each identified peptide the 15N incorporation rate is determined by comparing the experimental to a set of theoretical isotope patterns based on the peptide sequence. Relative quantitation is accomplished by calculating the signal intensity ratios for each 14N/15N peptide pair.  相似文献   

18.
Mass spectrometry has become indispensable for peptide and protein quantification in proteomics studies. When proteomics technologies are applied to understand the biology of plants, two-dimensional gel electrophoresis is still the prevalent method for protein fractionation, identification, and quantitation. In the present work, we have used LC-MS to compare an isotopic (ICPL) and isobaric (iTRAQ) chemical labeling technique to quantify proteins in the endosperm of Ricinus communis seeds at three developmental stages (IV, VI, and X). Endosperm proteins of each stage were trypsin-digested in-solution, and the same amount of peptides was labeled with ICPL and iTRAQ tags in two orders (forward and reverse). Each sample was submitted to nanoLC coupled to an LTQ-Orbitrap high-resolution mass spectrometer. Comparing labeling performance, iTRAQ was able to label 99.8% of all identified unique peptides, while 94.1% were labeled by ICPL. After statistical analysis, it was possible to quantify 309 (ICPL) and 321 (iTRAQ) proteins, from which 95 are specific to ICPL, 107 to iTRAQ, and 214 common to both labeling strategies. We noted that the iTRAQ quantification could be influenced by the tag. Even though the efficiency of the iTRAQ and ICPL in protein quantification depends on several parameters, both labeling methods were able to successfully quantify proteins present in the endosperm of castor bean during seed development and, when combined, increase the number of quantified proteins.  相似文献   

19.
Expressed prostatic secretion (EPS) is a proximal fluid directly derived from the prostate and, in the case of prostate cancer (PCa), is hypothesized to contain a repertoire of cancer-relevant proteins. Quantitative analysis of the EPS proteome may enable identification of proteins with utility for PCa diagnosis and prognosis. The present investigation demonstrates selective quantitation of proteins in EPS samples from PCa patients using a stable isotope labeled proteome standard (SILAP) generated through the selective harvest of the "secretome" from the PC3 prostate cancer cell line grown in stable isotope labeled cell culture medium. This stable isotope labeled secretome was digested with trypsin and equivalently added to each EPS digest, after which the resultant mixtures were analyzed by liquid chromatography-tandem mass spectrometry for peptide identification and quantification. Relative quantification of endogenous EPS peptides was accomplished by comparison of reconstructed mass chromatograms to those of the chemically identical SILAP peptides. A total of 86 proteins were quantified from 263 peptides in all of the EPS samples, 38 of which were found to be relevant to PCa. This work demonstrates the feasibility of using a SILAP secretome standard to simultaneously quantify many PCa-relevant proteins in EPS samples.  相似文献   

20.
Mass spectrometry has proved to be an important tool for protein biomarker discovery, identification and characterization. However, global proteomic profiling strategies often fail to identify known low-abundance biomarkers as a result of the limited dynamic range of mass spectrometry (two to three orders of magnitude) compared with the large dynamic range of protein concentrations in biologic fluids (11 to 12 orders of magnitude for serum). In addition, the number of peptides generated in such methods vastly overwhelms the resolution capacity of mass spectrometers, requiring extensive sample clean-up (e.g., affinity tag, retentate chromatography and/or high-performance liquid chromatography) before mass spectrometry analysis. Baiting and affinity pre-enrichment strategies, which overcome the dynamic range and sample complexity issues of global proteomic strategies, are very difficult to couple to mass spectrometry. This is due to the fact that it is nearly impossible to sort target peptides from those of the bait since there will be many cases of isobaric peptides. IDBEST (Target Discovery, Inc.) is a new tagging strategy that enables such pre-enrichment of specific proteins or protein classes as the resulting tagged peptides are distinguishable from those of the bait by a mass defect shift of approximately 0.1 atomic mass units. The special characteristics of these tags allow: resolution of tagged peptides from untagged peptides through incorporation of a mass defect element; high-precision quantitation of up- and downregulation by using stable isotope versions of the same tag; and potential analysis of protein isoforms through more complete peptide coverage from the proteins of interest.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号