首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Skin allografts, derived from cadaveric donors, are widely used for the treatment of burns and ulcers. Prior to use in clinical situations, these allografts are disinfected using a cocktail of antibiotics and then cryopreserved. Unfortunately, this antibiotic disinfection procedure fails to decontaminate a significant proportion and these contaminated grafts can not be used clinically. We have investigated whether it is possible to apply a second, more potent disinfection procedure to these contaminated grafts and effectively to re-process them for clinical use. Cadaveric skin grafts, treated with antibiotics and cryopreserved, were thawed and a peracetic acid (PAA) disinfection protocol applied. The grafts were then preserved in a high concentration of glycerol or propylene glycol, and properties thought to be essential for successful clinical performance assessed. The cytotoxicity of the grafts was assessed using both extract and contact assays; damage to the skin collagen was assessed using a collagenase susceptibility assay and the capacity of the grafts to elicit an inflammatory response in vitro was assessed by quantifying the production of the pro-inflammatory cytokine TNF-alpha by human peripheral blood mononuclear phagocytes. PAA disinfection, in conjunction with either glycerol or propylene glycol preservation, did not render the grafts cytotoxic, pro-inflammatory, or increase their susceptibility to collagenase digestion. The rates of penetration of glycerol and propylene glycol into the re-processed skin were comparable to those of fresh skin. This study has demonstrated that PAA disinfection combined with immersion in high concentrations of either glycerol or propylene glycol was an effective method for re-processing contaminated skin allografts, and may justify their clinical use.  相似文献   

2.
Patellar tendon auto- and allo-grafts are commonly used in orthopedic surgery for reconstruction of the anterior cruciate ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infectious disease transmission allografts should be radiation-sterilised. As radiation-sterilisation supposedly decreases the mechanical strength of tendon it is important to establish methods of allograft preservation and sterilisation assuring the best quality of grafts and their safety at the same time. Therefore, the purpose of this study was to compare the tensile strength of human patellar tendon (cut out as for ACL reconstruction), preserved by various methods (deep fresh freezing, glycerolisation, lyophilisation) and subsequently radiation-sterilised with doses of 0, 25, 50 or 100 kGy. Bone-Tendon-Bone grafts (BTB) were prepared from cadaveric human patella tendons with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glycerolisation or lyophilisation and were subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. All samples were subjected to mechanical failure tensile tests with the use of Instron system in order to estimate their mechanical properties. All lyophilised grafts were rehydrated before performing of those tests. Obtained mechanical tests results of examined grafts suggest that deep-frozen irradiated grafts retain their initial mechanical properties to an extent which does not exclude their clinical application. All conducted experiments were approved by the Local Ethical Committee.  相似文献   

3.
Quadriceps tendon with a patellar bone block may be a viable alternative to Achilles tendon for anterior cruciate ligament reconstruction (ACL-R) if it is, at a minimum, a biomechanically equivalent graft. The objective of this study was to directly compare the biomechanical properties of quadriceps tendon and Achilles tendon allografts. Quadriceps and Achilles tendon pairs from nine research-consented donors were tested. All specimens were processed to reduce bioburden and terminally sterilized by gamma irradiation. Specimens were subjected to a three phase uniaxial tension test performed in a custom environmental chamber to maintain the specimens at a physiologic temperature (37 ± 2 °C) and misted with a 0.9 % NaCl solution. There were no statistical differences in seven of eight structural and mechanical between the two tendon types. Quadriceps tendons exhibited a significantly higher displacement at maximum load and significantly lower stiffness than Achilles tendons. The results of this study indicated a biomechanical equivalence of aseptically processed, terminally sterilized quadriceps tendon grafts with bone block to Achilles tendon grafts with bone block. The significantly higher displacement at maximum load, and lower stiffness observed for quadriceps tendons may be related to the failure mode. Achilles tendons had a higher bone avulsion rate than quadriceps tendons (86 % compared to 12 %, respectively). This was likely due to observed differences in bone block density between the two tendon types. This research supports the use of quadriceps tendon allografts in lieu of Achilles tendon allografts for ACL-R.  相似文献   

4.
One major concern regarding soft tissue allograft use in surgical procedures is the risk of disease transmission. Current techniques of tissue sterilization, such as irradiation have been shown to adversely affect the mechanical properties of soft tissues. Grafts processed using Biocleanse processing (a proprietary technique developed by Regeneration Technologies to sterilize human tissues) will have better biomechanical characteristics than tissues that have been irradiated. Fifteen pairs of cadaveric Achilles tendon allografts were obtained and separated into three groups of 10 each. Three treatment groups were: Biocleanse, Irradiated, and Control (untreated). Each specimen was tested to determine the biomechanical properties of the tissue. Specimens were cyclically preloaded and then loaded to failure in tension. During testing, load, displacement, and optical strain data were captured. Following testing, the cross sectional area of the tendons was determined. Tendons in the control group were found to have a higher extrinsic stiffness (slope of the load–deformation curve, p = .005), have a higher ultimate stress (force/cross sectional area, p = .006) and higher ultimate failure load (p = .003) than irradiated grafts. Biocleanse grafts were also found to be stiffer than irradiated grafts (p = .014) yet were not found to be statistically different from either irradiated or non-irradiated grafts in terms of load to failure. Biocleanse processing seems to be a viable alternative to irradiation for Achilles tendon allografts sterilization in terms of their biomechanical properties.  相似文献   

5.
Bacterial contamination of tendon allografts at the completion of processing has historically been about 2 %, with tendons that are found to be culture positive being discarded. Treatment of tendon allograft with hydrogen peroxide at the beginning of tissue processing may reduce bacterial contamination, however, the potential side effects of hydrogen peroxide treatment include hydrolysis of the collagen and this may alter the mechanical properties of the graft. Pairs of human tendons were used. One was washed in 3 % hydrogen peroxide for 5 min and the untreated tendon was used as a control. The ultimate tensile strength of the tendons was determined using a material testing machine. A freeze clamp technique was used to hold the tendons securely at the high loads required to cause tendon failure. There was no statistical difference in the ultimate tensile strength between the treated and untreated tendons. Mean strength ranged from Extensor Hallucis Longus at 588 Newtons to Tibialis Posterior at 2,366 Newtons. Hydrogen peroxide washing may reduce bacterial contamination of tendon allograft and does not affect the strength of the tendon.  相似文献   

6.
Bacterial infection transmitted by human tissue allograft transplantation   总被引:3,自引:2,他引:1  
Bacterial contamination of tissue allografts obtained from cadaveric donors has been a serious cause of morbidity and mortality in recipients. Recent cases of fatal and nonfatal bacterial infections in recipients of contaminated articular cartilage (distal femur) and tendon allografts have called attention to the importance of avoiding tissue donors suspected of carrying infectious disease, of not processing donated tissue carrying virulent bacteria, the occurrence of falsely negative final sterility tests, and the need to sterilize tissues. These cases demonstrated that contamination can arise from an infected donor, during tissue removal from cadaveric donors, from the processing environment, and from contaminated supplies and reagents used during processing. Final sterility testing can be unreliable, especially when antibiotics remain on tissues. There is an increasing need for control of microbial contamination in tissue banks, and sterilization of tissue allografts should be recommended whenever possible.  相似文献   

7.
Frozen bone-patellar tendon bone allografts are useful in anterior cruciate ligament reconstruction as the freezing procedure kills tissue cells, thereby reducing immunogenicity of the grafts. However, a small portion of cells in human femoral heads treated by standard bone-bank freezing procedures survive, thus limiting the effectiveness of allografts. Here, we characterized the survival rates and mechanisms of cells isolated from rat bones and tendons that were subjected to freeze–thaw treatments, and evaluated the influence of these treatments on the mechanical properties of tendons. After a single freeze–thaw cycle, most cells isolated from frozen bone appeared morphologically as osteocytes and expressed both osteoblast- and osteocyte-related genes. Transmission electron microscopic observation of frozen cells using freeze-substitution revealed that a small number of osteocytes maintained large nuclei with intact double membranes, indicating that these osteocytes in bone matrix were resistant to ice crystal formation. We found that tendon cells were completely killed by a single freeze–thaw cycle, whereas bone cells exhibited a relatively high survival rate, although survival was significantly reduced after three freeze–thaw cycles. In patella tendons, the ultimate stress, Young’s modulus, and strain at failure showed no significant differences between untreated tendons and those subjected to five freeze–thaw cycles. In conclusion, we identified that cells surviving after freeze–thaw treatment of rat bones were predominantly osteocytes. We propose that repeated freeze–thaw cycles could be applied for processing bone-tendon constructs prior to grafting as the treatment did not affect the mechanical property of tendons and drastically reduced surviving osteocytes, thereby potentially decreasing allograft immunogenecity.  相似文献   

8.
Human skin allografts are used worldwide as an adjunct for the healing of burns when autograft skin is not available or not indicated. Allograft skin comes from human cadaveric donors, and so must be preserved until use. This study forms the first investigation to compare the mechanical and histological integrity of human split-thickness skin grafts preserved by either glycerolisation or cryopreservation (with or without the cryoprotectant DMSO). Stress relaxation was used to assess mechanical properties, whilst histological analysis allowed for evaluation of structural integrity.  相似文献   

9.
Tendon allografts, when autograft options are limited or when obtaining an autograft is not aligned with the patients’ best interest, play an important role in tendon and ligament reconstruction. To minimize the risk of infectious disease transmission tissue banks perform screening tests and the allografts cleaned are sterilized. The current study examines and compares the initial mechanical properties and histological appearance of supercritical CO2 (SCCO2)-treated and gamma-irradiated porcine extensor tendons. Thirty intact porcine forelimb extensor tendons randomized equally into three groups: control group, gamma-irradiation group, and SCCO2-treated group. Once treated, histological assessment and histomorphologic measurements were made on the histological sections obtained from each tendon while stiffness and ultimate failure loads were evaluated from tensile testing. Histological evaluation of gamma-irradiated tendons showed significant disruption to the hierarchical morphology of the fascicle bundles, which was not evident in SCCO2-treated specimens. Histomorphologic measurements showed a significant increase for measured dead space (void) between tendon fibrils of the gamma-irradiated group comparing to both control and SCCO2 treated groups (p?<?0.01). There was a significant reduction in the ultimate failure load for tendons treated by gamma-irradiation compared to the control group (p?<?0.05). No statistically significant difference was detected between control and SCCO2-treated tendons in the ultimate failure load. Stiffness values were not significantly different between three-study groups. This study suggests that while gamma-irradiation has a deleterious effect on mechanical properties of tendon tissue, SCCO2 does not alter the biomechanical properties and the histological structure of porcine extensor tendons.  相似文献   

10.
In order to maintain their native properties, cryopreserved tendons are usually used in biomechanical research and in transplantation of allogenic tendon grafts. The use of different study protocols leads to controversy in literature and thus complicates the evaluation of the current literature. The aim of this study consisted in examining the influence of different freezing and thawing temperatures on the mechanical properties of tendons. 60 porcine tendons were frozen at either −80 °C or −20 °C for 7 days and thawed at room or body temperature for 240 or 30 min, respectively. A subgroup of ten tendons was quick-frozen with liquid nitrogen (−196 °C) for 2 s before cryopreservation. Biomechanical testing was performed with a material testing machine and included creep, cyclic and load-to-failure tests. The results showed that freezing leads to a reduced creep strain after constant loading and to an increased secant modulus. Freezing temperature of −80 °C increased the secant modulus and decreased the strain at maximum stress, whereas thawing at room temperature reduced the maximum stress, the strain at initial tendon failure and the Young’s Modulus. Quick-freezing led to increased creep strain after constant loading, increased strain at initial failure in the load-to-failure test, and decreased strain at maximum stress. When cryopreserving, tendons for scientific or medical reasons, freezing temperature of −20 °C and thawing temperature of 37.5 °C are recommended to maintain the native properties of tendons. A treatment with liquid nitrogen in the sterilization process of tendon allografts is inadvisable because it alters the tendon properties negatively.  相似文献   

11.
Allograft musculoskeletal tissue is commonly used in orthopaedic surgical procedures. Cadaveric donors of musculoskeletal tissue supply multiple allografts such as tendons, ligaments and bone. The microbiology laboratory of the South Eastern Area Laboratory Services (SEALS, Australia) has cultured cadaveric allograft musculoskeletal tissue samples for bacterial and fungal isolates since 2006. This study will retrospectively review the micro-organisms isolated over a 6-year period, 2006–2011. Swab and tissue samples were received for bioburden testing and were inoculated onto agar and/or broth culture media. Growth was obtained from 25.1 % of cadaveric allograft musculoskeletal tissue samples received. The predominant organisms isolated were coagulase-negative staphylococci and coliforms, with the heaviest bioburden recovered from the hemipelvis. The rate of bacterial and fungal isolates from cadaveric allograft musculoskeletal tissue samples is higher than that from living donors. The type of organism isolated may influence the suitability of the allograft for transplant.  相似文献   

12.
Musculoskeletal allografts are typically disinfected using antibiotics, irradiation or chemical methods but protocols vary significantly between tissue banks. It is likely that different disinfection protocols will not have the same level of microorganism kill; they may also have varying effects on the structural integrity of the tissue, which could lead to significant differences in terms of clinical outcome in recipients. Ideally, a disinfection protocol should achieve the greatest bioburden reduction with the lowest possible impact on tissue integrity. A systematic review of three databases found 68 laboratory and clinical studies that analyzed the microbial bioburden or contamination rates of musculoskeletal allografts. The use of peracetic acid–ethanol or ionizing radiation was found to be most effective for disinfection of tissues. The use of irradiation is the most frequently published method for the terminal sterilization of musculoskeletal allografts; it is widely used and its efficacy is well documented in the literature. However, effective disinfection results were still observed using the BioCleanse? Tissue Sterilization process, pulsatile lavage with antibiotics, ethylene oxide, and chlorhexidine. The variety of effective methods to reduce contamination rate or bioburden, in conjunction with limited high quality evidence provides little support for the recommendation of a single bioburden reduction method.  相似文献   

13.
The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. Gamma irradiation is an effective method for providing terminal sterilization to biological tissue, but it is also reported to have deleterious effects on tissue mechanics in a dose-dependent manner. At irradiation ranges up to 25 kGy, a clear relationship between mechanical strength and dose has yet to be established. The aim of this study was to investigate the mechanical properties of bone and soft tissue allografts, irradiated on dry ice at a low absorbed dose (18.3–21.8 kGy) and a moderate absorbed dose (24.0–28.5 kGy), using conventional compressive and tensile testing, respectively. Bone grafts consisted of Cloward dowels and iliac crest wedges, while soft tissue grafts consisted of patellar tendons, anterior tibialis tendons, semitendinosus tendons, and fascia lata. There were no statistical differences in mechanical strength or modulus of elasticity for any graft irradiated at a low absorbed dose, compared to control groups. Also, bone allografts and two soft tissue allografts (anterior tibialis and semitendinosus tendon) that were irradiated at a moderate dose demonstrated similar strength and modulus of elasticity values to control groups. The results of this study support the use of low dose and moderate dose gamma irradiation of bone grafts. For soft tissue grafts, the results support the use of low dose irradiation.  相似文献   

14.
An increasing number of tissue banks have begun to focus on gamma irradiation and freeze-thaw in the reconstruction of anterior cruciate ligaments using allografts. The purpose of this study was to evaluate the biomechanical properties of human tendons after exposure to gamma radiation and repeated freeze-thaw cycles and to compare them with fresh specimens. Forty flexor digitorum superficialis tendons were surgically procured from five fresh cadavers and divided into four groups: fresh tendon, gamma irradiation, freeze-thaw and gamma irradiation+freeze-thaw. The dose of gamma irradiation was 25 kGy. Each freeze-thaw cycle consisted of freezing at -80 °C for 7 day and thawing at 25 °C for 6 h. These tendons underwent 4 freeze-thaw cycles. Biomechanical properties were analyzed during load-to-failure testing. The fresh tendons were found to be significantly different in ultimate load, stiffness and ultimate stress relative to the other three groups. The tendons of the gamma+freeze-thaw group showed a significant decrease in ultimate load, ultimate stress and stiffness compared with the other three groups. Gamma irradiation and repeated freezing-thawing (4 cycles) can change the biomechanical properties. However, no significant difference was found between these two processes on the effect of biomechanical properties. It is recommended that gamma irradiation (25 kGy) and repetitive freeze-thaw cycles (4 cycles) should not be adopted in the processing of the allograft tendons.  相似文献   

15.
The secondary sterilisation by irradiation reduces the risk of infectious disease transmission with tissue allografts. Achieving sterility of bone tissue grafts compromises its biomechanical properties. There are several factors, including dose and temperature of irradiation, as well as processing conditions, that may influence mechanical properties of a bone graft. The purpose of this study was to evaluate the effect of gamma irradiation with doses of 25 or 35?kGy, performed on dry ice or at ambient temperature, on mechanical properties of non-defatted or defatted compact bone grafts. Left and right femurs from six male cadaveric donors aged from 46 to 54?years, were transversely cut into slices of 10?mm height, parallel to the longitudinal axis of the bone. Compact bone rings were assigned to the eight experimental groups according to the different processing method (defatted or non-defatted), as well as gamma irradiation dose (25 or 35?kGy) and temperature conditions of irradiation (ambient temperature or dry ice). Axial compression testing was performed with a material testing machine. Results obtained for elastic and plastic regions of stress-strain curves examined by univariate analysis are described. Based on multivariate analysis it was found that defatting of bone rings had no significant effect on any mechanical parameter studied, whereas irradiation with both doses decreased significantly the ultimate strain and its derivative toughness. The elastic limit and resilience were significantly increased by irradiation with the dose 25?kGy, but not 35?kGy, when the time of irradiation was longer. Additionally, irradiation at ambient temperature decreased maximum load, elastic limit, resilience, and ultimate stress. As strain in the elastic region was not affected, decreased elastic limit resulted in lower resilience. The opposite phenomenon was observed in the plastic region, where in spite of the lower ultimate stress, the toughness was increased due to the increase in the ultimate strain. The results of our study suggest that there may be an association between mechanical properties of bone tissue grafts and the damage process of collagen structure during gamma irradiation. This collagen damage in cortical bone allografts containing water does not depends on the temperature of irradiation or defatting during processing if dose of gamma irradiation does not exceed 35?kGy.  相似文献   

16.
Although allografts for anterior cruciate ligament (ACL) replacement have shown advantages compared to autografts, their use is limited due to the risk of disease transmission and the limitations of available sterilization methods. Gamma sterilization has shown detrimental effects on graft properties at the high doses required for sufficient pathogen inactivation. In our previous in vitro study on human patellar tendon allografts, Electron beam (Ebeam) irradiation showed less detrimental effects compared to gamma sterilization (Hoburg et al. in Am J Sports Med 38(6):1134-1140, 2010). To investigate the biological healing and restoration of the mechanical properties of a 34?kGy Ebeam treated tendon allograft twenty-four sheep underwent ACL replacement with either a 34?kGy Ebeam treated allograft or a non-sterilized fresh frozen allograft. Biomechanical testing of stiffness, ultimate failure load and AP-laxity as well as histological analysis to investigate cell, vessel and myofibroblast-density were performed after 6 and 12?weeks. Native sheep ACL and hamstring tendons (HAT, each n?=?9) served as controls. The results of a previous study analyzing the remodeling of fresh frozen allografts (n?=?12) and autografts (Auto, n?=?18) with the same study design were also included in the analysis. Statistics were performed using Mann-Whitney U test followed by Bonferroni-Holm correction. Results showed significantly decreased biomechanical properties during the early remodeling period in Ebeam treated grafts and this was accompanied with an increased remodeling activity. There was no recovery of biomechanical function from 6 to 12?weeks in this group in contrast to the results observed in fresh frozen allografts and autografts. Therefore, high dose Ebeam irradiation investigated in this paper cannot be recommended for soft tissue allograft sterilization.  相似文献   

17.
Cardiovascular allografts are usually disinfected using antibiotics, but protocols vary significantly between tissue banks. It is likely that different disinfection protocols will not have the same level of efficacy; they may also have varying effects on the structural integrity of the tissue, which could lead to significant differences in terms of clinical outcome in recipients. Ideally, a disinfection protocol should achieve the greatest bioburden reduction with the lowest possible impact on tissue integrity. We conducted a systematic review of methods applied to disinfect cardiovascular tissues. The use of multiple broad spectrum antibiotics in conjunction with an antifungal agent resulted in the greatest reduction in bioburden. Antibiotic incubation periods were limited to less than 24 h, and most protocols incubated tissues at 4 °C, however one study demonstrated a greater reduction of microbial load at 37 °C. None of the reviewed studies looked at the impact of these disinfection protocols on the risk of infection or any other clinical outcome in recipients.  相似文献   

18.
Terminal sterilization of tendon allografts with high dose gamma irradiation has deleterious effects on tendon mechanical properties and stability after implantation. Our goal is to minimize these effects with radio protective methods. We previously showed that radio protection via combined crosslinking and free radical scavenging maintained initial mechanical properties of tendon allografts after irradiation at 50 kGy. This study further evaluates the tissue response and simulated mechanical degradation of tendons processed with radio protective treatment, which involves crosslinking in 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide followed by soaking in an ascorbate/riboflavin-5-phosphate solution. Control untreated and treated tendons were irradiated at 50 kGy and implanted in New Zealand White rabbit knees within the joint capsule for four and 8 weeks. Tendons were also exposed to cyclic loading to 20 N at one cycle per 12 s in a collagenase solution for 150 cycles, followed by tension to failure. Control irradiated tendons displayed increased degradation in vivo, and failed prematurely during cyclic processing at an average of 25 cycles. In contrast, radio protected irradiated tendons displayed greater stability following implantation over 8 weeks, and possessed strength at 59 % of native tendons and modulus equivalent to that of native tendons after cyclic loading in collagenase. These results suggest that radio protective treatment improves the strength and the stability of tendon allografts.  相似文献   

19.
To avoid the risk of infectious disease transmission from donor to recipient, allografts should be terminally sterilized. In the previous paper (Kaminski et al. in Cell Tissue Bank 10:215–219, 2009) we presented the effect of various methods of preservation (deep fresh freezing, glycerolization, lyophilization), followed by irradiation with different doses of electron beam (EB), on material (intrinsic) mechanical properties of human patellar tendons cut out as for anterior cruciate ligament reconstruction, obtained in failure tensile test. As structural mechanical properties are equally important to predict the behaviour of the graft as a whole functional unit, the purpose of the present paper was to show the results for failure load and elongation, obtained in the same experiment. Paired Bone-Tendon-Bone grafts (BTB) were prepared from cadaveric human patella tendons with both patellar and tibial attachments. They were preserved by deep freezing, glycerolization or lyophilization and subsequently EB-irradiated with the doses of 25, 35, 50 or 100 kGy (fresh-frozen grafts) or a single dose of 35 kGy (glycerolized and lyophilized grafts). Each experimental (irradiated) group was provided with control (non-irradiated), donor-matched group. The specimens from all groups were subjected to mechanical failure tensile test with the use of Instron system in order to measure their structural properties (failure load and elongation). All lyophilized grafts were rehydrated before mechanical testing. In our study we did not observe significant deterioration of structural mechanical properties of BTB grafts processed by fresh-freezing and then terminal sterilized with growing doses of EB up to 100 kGy. In contrast, BTB grafts processed by glycerolization or lyophilization and irradiated with 35 kGy showed significant decrease of failure load. Obtained results suggest that deep-frozen irradiated grafts retain their initial mechanical properties to an extent which does not exclude their clinical application. However, biomechanical investigations constitute only the first step to evaluate the potential clinical usefulness of such allografts and further extensive in vivo studies are needed.  相似文献   

20.
Due to ready availability, decreased cost, and freedom from transmissible diseases in humans such as hepatitis and AIDS, it would be advantageous to use tendon grafts from farm animals as a substitute for human tendon grafts in in vitro experiments aimed at improving the outcome of anterior cruciate ligament (ACL) reconstructive surgery. Thus the objective of this study was to determine whether an anterior cruciate ligament (ACL) graft composed of two loops of bovine common digital extensor tendon has the same viscoelastic, structural, and material properties as a graft composed of a double loop of semitendinosus and gracilis tendons from humans. To satisfy this objective, grafts were constructed from each tissue source. The cross-sectional area was measured using an area micrometer, and each graft was then pulled using a materials testing system while submerged in a saline bath. Using two groups of tendon grafts (n = 10), viscoelastic tests were conducted over a three-day period during which a constant displacement load relaxation test was followed by a constant amplitude, cyclic load creep test (first day), a constant load creep test (second day), and an incremental cyclic load creep test (third day). Load-to-failure tests were performed on two different groups of grafts (n = 8). When the viscoelastic behavior was compared, there were no significant differences in the rate of load decay or the final load (relaxation test) and rates of displacement increase or final displacements (creep tests) (p > 0.115). To compare both the structural and material properties in the toe region (i.e., < 250 N) of the load-elongation curve, the tangent stiffness and modulus functions were computed from parameters used in an exponential model fit to the load (stress)-elongation (strain) data. Although one of the two parameters in the functions was different statistically, this difference translated into a difference of only 0.03 mm in displacement at 250 N of load. In the linear region (i.e., 50-75 percent of ultimate load) of the load-elongation curve, the linear stiffness of the two graft types compared closely (444 N/mm for bovine and 418 N/mm for human) (p = 0.341). At failure, the ultimate loads (2901 N and 2914 N for bovine and human, respectively) and the ultimate stresses (71.8 MPa and 65.6 MPa for bovine and human, respectively) were not significantly different (p > 0.261). The theoretical effect of any differences in properties between these two grafts on the results of two types of in vitro experiments (i.e., effect of surgical variables on knee laxity and structural properties of fixation devices) are discussed. Despite some statistical differences in the properties evaluated, these differences do not translate into important effects on the dependent variables of interest in the experiments. Thus the bovine tendon graft can be substituted for the human tendon graft in both types of experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号