首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The goal of the present study was to obtain a systematic set of data along the length of the mouse aorta to study variations of morphometry (diameter, wall thickness, and curvature), strain, and stress of the mouse aorta. Five mice were imaged with a 13-MHz ultrasound probe to determine the in vivo diameter along the aorta. A cast was made of these aortas to validate the ultrasonic diameter measurements. The root mean squared and systematic errors for these measurements were 12.6% and 6.4% of the mean ultrasound diameter, respectively. The longitudinal variations of geometry, stress, and strain from the aortic valve to the common iliac bifurcation were documented. Our results show that the residual circumferential strain leads to a uniformity of transmural strain of the aorta in the loaded state along the entire length of the aorta. Furthermore, we validated the incompressibility condition along the length of the aorta. These data of normal mice will serve as a reference state for the study of disease in future knockout models.  相似文献   

2.
Experiments were performed to study biaxial anisotropy in relaxed canine carotid arteries subjected to a wide range of longitudinal lengths and transmural pressures. In order to encompass the range of vessel lengths which occurs in situ, 120 carotid arteries were studied at 20%, 40%, 60% and 80% extension relative to retracted vessel length. These studies were performed in systematically randomized order. At each length, the vessels were pressurized in steps up to 200 mmHg transmural pressure, or until the traction force fell to zero. Results showed that longitudinal extension markedly increased the longitudinal elastic modulus, but had only a slight effect on the circumferential modulus. At physiological pressures, the vessels were nearly isotropic at about 70% longitudinal extension, but were anisotropic at shorter lengths. Estimates of the anisotropic circumferential modulus by a number of simplified methods revealed that use of a 'pressure-elastic modulus' (Ep) underestimated the anisotropic modulus by 80%, but was extremely consistent. Therefore when suitably corrected, Ep could be used to reliably estimate the anisotropic modulus of carotid arteries over a wide range of pressures and vessel lengths.  相似文献   

3.
The passive anisotropic elastic properties of rat's aorta were studied in vitro by subjecting cylindrical segments of thoracic and abdominal aorta to a wide range of deformations. Using data on pressure, axial stretch, outer diameter, axial force and wall thickness, incremental moduli of elasticity in the circumferential, axial and radial directions were computed. Results indicate that while the elastic behavior of the aortic wall is globally anisotropic, there exists a state of deformation at which the vessel displays incremental isotropy. This state of deformation corresponds approximately to the loading conditions to which the aorta is exposed in situ. Values of the moduli, analyzed as a function of transmural pressure, show that the stiffness of the aortic wall is fairly constant at low pressures but raises steeply for pressures higher than physiological. For axial stretches as occurring in situ, the magnitudes of the circumferential and radial moduli do not differ significantly for the thoracic aorta; hence this vessel can be regarded as transversely isotropic over a wide range of pressures. The same observation is valid also for the abdominal aorta when pressures equal or smaller than physiological are considered. For both the thoracic and abdominal segments of the aorta, the circumferential and radial moduli are smaller than the axial modulus at low pressures, while the reverse is true for large pressures.  相似文献   

4.
The existence of a homeostatic state of stresses and strains has been axiomatic in the cardiovascular system. The objective of this study was to determine the distribution of circumferential stress and strain along the aorta and throughout the coronary arterial tree to test this hypothesis. Silicone elastomer was perfused through the porcine aorta and coronary arterial tree to cast the arteries at physiological pressure. The loaded and zero-stress dimensions of the vessels were measured. The aorta (1.8 cm) and its secondary branches were considered down to 1.5 mm diameter. The left anterior descending artery (4.5 mm) and its branches down to 10 microm were also measured. The Cauchy mean circumferential stress and midwall stretch ratio were calculated. Our results show that the stretch ratio and Cauchy stress were lower in the thoracic than in the abdominal aorta and its secondary branches. The opening angle (theta) and midwall stretch ratio (lambda) showed a linear variation with order number (n) as follows: theta = 10.2n + 63.4 (R(2) = 0.989) and lambda = 4.47 x 10(-2)n + 1.1 (R(2) = 0.995). Finally, the stretch ratio and stress varied between 1.2 and 1.6 and between 10 and 150 kPa, respectively, along the aorta and left anterior descending arterial tree. The relative uniformity of strain (50% variation) from the proximal aorta to a 10-microm arteriole implies that the vascular system closely regulates the degree of deformation. This suggests a homeostasis of strain in the cardiovascular system, which has important implications for mechanotransduction and for vascular growth and remodeling.  相似文献   

5.
The hemodynamic conditions of aorta are relatively uniform prenatally and become more heterogeneous postnatally. Our objective was to quantify the heterogeneity of geometry and mechanical properties during growth and development. To accomplish this objective, we obtained a systematic set of data on the geometry and mechanical properties along the length of mouse aorta during postnatal development. C57BL/6 mice of ages 1-33 days were studied. The ascending aorta was cannulated in situ and preconditioned with several cyclic changes in pressure. We investigated the axial variations of geometry (diameter and length) and mechanical properties (stress-stain relation, elastic modulus and compliance) of the mouse aorta from the aortic valve to the common iliac. Our results show that the arterial blood pressure of mice increased from approximately 30 to 80 mmHg during the first 2 wk of life. The stretch ratio, diameter, wall (intima-media) thickness, and total lumen volume of mouse aorta increased with age. The aorta was transformed from a cylindrical tube at birth to a tapered structure during growth. Furthermore, we found the mechanical properties were fairly uniform along the length of the aorta at birth and become more nonuniform with age. We conclude that the rapid change of blood pressure and blood flow after birth alter the geometric and mechanical properties differentially along the length of the aorta. Hence, the axial nonuniformity of the aorta increases as the organ becomes more specialized during growth and development.  相似文献   

6.
BACKGROUND: Robust techniques for characterizing the biomechanical properties of mouse pulmonary arteries will permit exciting gene-level hypotheses regarding pulmonary vascular disease to be tested in genetically engineered animals. In this paper, we present the first measurements of the biomechanical properties of mouse pulmonary arteries. METHOD OF APPROACH: In an isolated vessel perfusion system, transmural pressure, internal diameter and wall thickness were measured during inflation and deflation of mouse pulmonary arteries over low (5-40 mmHg) and high (10-120 mmHg) pressure ranges representing physiological pressures in the pulmonary and systemic circulations, respectively. RESULTS: During inflation, circumferential stress versus strain showed the nonlinear "J"-shape typical of arteries. Hudetz's incremental elastic modulus ranged from 27 +/- 13 kPa (n = 7) during low-pressure inflation to 2,700 +/- 1,700 kPa (n = 9) during high-pressure inflation. The low and high-pressure testing protocols yielded quantitatively indistinguishable stress-strain and modulus-strain results. Histology performed to assess the state of the tissue after mechanical testing showed intact medial and adventitial architecture with some loss of endothelium, suggesting that smooth muscle cell contractile strength could also be measured with these techniques. CONCLUSIONS: The measurement techniques described demonstrate the feasibility of quantifying mouse pulmonary artery biomechanical properties. Stress-strain behavior and incremental modulus values are presented for normal, healthy arteries over a wide pressure range. These techniques will be useful for investigations into biomechanical abnormalities in pulmonary vascular disease.  相似文献   

7.
Venous occlusion strain gauge plethysmography (VOP) is based on the assumption that the veins are occluded and arterial inflow is undisturbed by the venous cuff pressure. Literature is not clear concerning the pressure that should be used. The purpose of this study was to determine the optimal venous occlusion pressure at which the highest arterial inflow is achieved in the forearm, calf, and leg by using VOP. We hypothesized that, for each limb segment, an optimal (range of) venous cuff pressure can be determined. Arterial inflow in each limb segment was measured in nine healthy individuals by VOP by using pressures ranging from 10 mmHg up to diastolic blood pressure. Arterial inflows were similar at cuff pressures between 30 and 60 mmHg for the forearm, leg, and calf. Arterial inflow in the forearm was significantly lower at 10 mmHg compared with the other cuff pressures. In addition, arterial inflows at 20 mmHg tended to be lower in each limb segment than flow at higher cuff pressures. In conclusion, no single optimum venous cuff pressure, at which a highest arterial inflow is achieved, exists, but rather a range of optimum cuff pressures leading to a similar arterial inflow. Venous cuff pressures ranging from 30 mmHg up to diastolic blood pressure are recommended to measure arterial inflow by VOP.  相似文献   

8.
The present study was designed to take advantage of telemetry data acquisition and develop an easy and reliable system to servocontrol renal perfusion pressure (RPP). Digitized pressure signals from lower abdominal aorta in rats, reflecting RPP, was obtained by a telemetry device and dynamically exported into an Excel worksheet. A computer program (LabVIEW) compared the RPP data with a preselected pressure range and drove a bidirectional syringe pump to control the inflation of a vascular occluder around the aorta above renal arteries. When RPP was higher than the preselected range, the syringe pump inflated the occluder and decreased RPP, and vice versa. If RPP was within range, there was no action. In this way, RPP was servocontrolled within the desired range. In experiments with norepinephrine- or ANG II-induced acute increases in systemic arterial pressure (120-145 mmHg), the system controlled RPP at a constant range of 100-105 mmHg within 30-50 s and differentiated the pressure-dependent and -independent effects on renal functions. In Dahl S rats with high-salt-induced hypertension, this system maintained RPP at 100-120 mmHg over 10 days, while systemic arterial pressures were 150 +/- 5.9 mmHg in uncontrolled animals. This system also has the ability of simultaneity and multiplexing to control multiple animals. Our results suggest that this is an effective and reliable system to servocontrol RPP, which can be easily established with general computer knowledge. This system provides a powerful tool and may greatly facilitate the studies in pressure-dependent/-independent effects of a variety of cardiovascular factors.  相似文献   

9.
Understanding the mechanical environment of each component within the arterial wall is fundamental for understanding vascular growth and remodelling and for engineering artificial vascular conduits. We have investigated the mechanical status of arterial elastin by measuring the circumferential mechanical properties of purified elastin as function of position along the descending thoracic aorta of the pig. The tensile circumferential secant modulus, E(sec), measured in uniaxial mechanical tests, increased 30% (P<0.001), from a value of 0.88 MPa in the proximal tissue near the aortic arch to 1.14 MPa in the distal tissue near the diaphragm, indicating the stiffness of the elastin sample increased with position. Breaking stress was 54% higher in the distal tissue compared to the proximal (P<0.001), but the breaking stretch ratio did not change. E(sec) correlated with the ratio of radius to wall thickness measured in the no load state, r(nl)/h(nl), suggesting that the rise in stiffness was linked to ring morphology. The higher stiffness and strength of the distal tissue might be explained by a higher proportion of circumferentially oriented fibres in the distal tissue, which would indicate that the elastin meshwork in the thoracic aorta may become progressively anisotropic with distance from the heart. The ratio r(nl)/(h(nl)E (sec))rose only 7%, which suggests that the in vivo circumferential strain on the elastin may be constant along the pig thoracic aorta. The positional variation in elastin's properties should be taken into account in mechanical studies on purified elastin and in mathematical models of aorta mechanics.  相似文献   

10.
Our aim was to define normal esophagogastric junction (EGJ) morphology and relaxation characteristics using high-resolution manometry (HRM). To this end, 75 asymptomatic controls underwent HRM with a solid-state manometric assembly incorporating 36 circumferential sensors spaced at 1-cm intervals positioned to record from the hypopharynx to the stomach. Ten 5-ml water swallows were obtained. EGJ relaxation was quantified by 1) nadir pressure, 2) the lowest 3-s mean residual pressure after swallow (E-sleeve), and 3) the transsphincteric gradient 2-6 s after swallowing measured from 2 cm above to 2 cm below the EGJ. A new parameter, integrated relaxation resistance (IRR), was also calculated. The IRR calculation accounted for both the duration of EGJ relaxation and instantaneous E-sleeve-type relaxation pressures during the entire interval of relaxation. The means and ranges (5-95th percentile) for nadir lower esophageal sphincter relaxation pressure (mean: 3.9 mmHg, range: 0-10.1 mmHg) and E-sleeve relaxation pressure (mean: 8.1 mmHg, range: 4.1-15.1 mmHg) were consistent with previously reported values. The mean relaxation interval was 7.95 +/- 0.2 s (mean +/- SE), whereas the median relaxation pressure during that interval was 10.7 +/- 0.5 mmHg (mean +/- SE). Mean IRR was 1.3 mmHg/s (95th percentile: 3.0 mmHg/s). Mean EGJ length was 3.7 cm. In conclusion, HRM provides a seamless dynamic representation of pressure within and across the EGJ. In addition to providing conventional EGJ relaxation parameters, this technology also creates opportunities to quantify more precise measures of EGJ relaxation and morphology.  相似文献   

11.
This study was undertaken to understand elastin's role in the mechanical homeostasis of the arterial wall. The mechanical properties of elastin vary along the aorta, and we hypothesized this maintained a uniform mechanical environment for the elastin, despite regional variation in loading. Elastin's physiological loading was determined by comparing the inflation response of intact and autoclave purified elastin aortas from the proximal and distal thoracic aorta. Elastin's stretch and stress depend on collagen recruitment. Collagen recruitment started in the proximal aorta at systolic pressures (13.3 to 14.6 kPa) and in the distal at sub-diastolic pressures (9.3 to 10.6 kPa). In the proximal aorta collagen did not contribute significantly to the stress or stiffness, indicating that elastin determined the vessel properties. In the distal aorta, the circumferential incremental modulus was 70% higher than in the proximal aorta, half of which (37%) was due to a stiffening of the elastin. Compared to the elastin tissue in the proximal aorta, the distal elastin suffered higher physiological circumferential stretch (29%, P=0.03), circumferential stress (39%, P=0.02), and circumferential stiffness (37%, P=0.006). Elastin's physiological axial stresses were also higher (67%, P=0.003). These findings do not support the hypothesis that the loading on elastin is constant along the aorta as we expected from homeostasis.  相似文献   

12.
As the complete understanding of urinary bladder function requires knowledge of organ level deformations, we conducted ex vivo studies of surface strains of whole bladders during controlled filling. The surface strains derived from displacements of surface markers applied to the posterior surface of excised rat bladders were tracked under slow filling with pressure and volume simultaneously recorded in the passive and completely inactivated states (i.e. with and without smooth muscle tone, respectively). Bladders evaluated in the passive state exhibited spontaneous contractions and larger average peak pressures (16.7 mmHg compared to 6.4 mmHg in the inactive state). Overall, the bladders exhibited anisotropic deformations and were stiffer in the circumferential direction, with average peak stretch values of ~2.3 and ~1.9 in the longitudinal and circumferential directions, respectively, for both states. Although bladders in the passive state were stiffer, they had similar average peak areal stretches of 4.3 in both states. However, differences early in the filling process as a result of a loss in smooth muscle tone in the inactive state resulted in longitudinal lengthening of 36%. Idealizing the bladder as a prolate spheroid, we estimated the wall stress–strain relation during filling and demonstrated that the intact bladder exhibited the classic stress–stretch relation, with a significantly protracted low stress region and peak stresses of 36 and 51 kPa in the longitudinal and circumferential directions, respectively. The present study fills a major gap in the urinary bladder biomechanics literature, wherein knowledge of the pressure–volume–wall stress–wall strain relation was explored for the first time in a functioning organ ex vivo.  相似文献   

13.
Zhao J  Lu X  Zhuang F  Gregersen H 《Biorheology》2000,37(5-6):385-400
Morphometric and passive biomechanical properties were studied in isolated segments of the thoracic and abdominal aorta, left common carotid artery, left femoral artery and the left pulmonary artery in 20 non-diabetic and 28 streptozotocin (STZ)-induced diabetic rats. The diabetic and non-diabetic rats were divided into groups living 1, 4, 8, and 12 weeks after the induction of diabetes (n = 7 for each diabetic group) or sham injection (n = 5 for each group). The mechanical test was performed as a distension experiment where the proximal end of the arterial segment was connected via a tube to the container used for applying pressures to the segment and the distal end was left free. The vessel diameter and length were obtained from digitized images of the arterial segments at pre-selected pressures and at no-load and zero-stress states. Circumferential and longitudinal stresses (force per area) and strains (deformation) were computed from the length, diameter and pressure data and from the zero-stress state data. The zero-stress state was obtained by cutting vessel rings radially causing the rings to open up into a sector. Diabetes was associated with pronounced morphometric changes, e.g., wall thickness. With respect to the biomechanical data, the opening angle increased and reached a plateau in 4 weeks after which it decreased again (p < 0.05). The opening angle was smallest in the thoracic aorta and largest in the pulmonary artery. Furthermore, it was found that the circumferential stiffness of the arteries studied increased with the duration of diabetes. In the longitudinal direction significant differences were found 8 weeks after injection of STZ in all arteries except the pulmonary artery. In the 12 weeks group, the femoral artery was stiffest in the circumferential direction whereas the thoracic aorta was stiffest in the longitudinal direction. The accumulated serum glucose level correlated with the arterial wall thickness and elastic modulus (correlation coefficient between 0.56 and 0.81).  相似文献   

14.
Some pathological conditions may affect osmolarity, which can impact cell, tissue, and organ volume. The hypothesis of this study is that changes in osmolarity affect the zero-stress state and mechanical properties of the aorta. To test this hypothesis, a segment of mouse abdominal aorta was cannulated in vivo and mechanically distended by perfusion of physiological salt (NaCl) solutions with graded osmolarities from 145 to 562 mosM. The mechanical (circumferential stress, strain, and elastic modulus) and morphological (wall thickness and wall area) parameters in the loaded state were determined. To determine the osmolarity-induced changes of zero-stress state, the opening angle was observed by immersion of the sectors of mouse, rat, and pig thoracic aorta in NaCl solution with different osmolarities. Wall volume and tissue water content of the rings were also recorded at different osmolarities. Our results show that acute aortic swelling due to low osmolarity leads to an increase in wall thickness and area, a change in the stress-strain relationship, and an increase in the elastic modulus (stiffness) in mouse aorta. The opening angle, wall volume, and water content decreased significantly with increase in osmolarity. These findings suggest that acute aortic swelling and shrinking result in immediate mechanical changes in the aorta. Osmotic pressure-induced changes in the zero-stress state may serve to regulate mechanical homeostasis.  相似文献   

15.
Segments of 45 human thoracic and 20 abdominal aortas, including 13 pairs, aged 30-88 yr at autopsy, were perfused with 37 degrees C Tyrode's solution at in-situ length. Diameter changes due to 20 mmHg pressure steps, between 20 and 180 mmHg, were measured to 1 micron accuracy with balanced transducers. Absolute diameter at 100 mmHg was measured to 50 micron accuracy. At 100 mmHg, cross-sectional area ranged from 2.6 to 7.6 for thoracic and from 1.0 to 3.2 cm2 for abdominal segments. Compliances ranged from 1.9 to 17 for thoracic and from 0.6 to 4.4 mm3/mmHg.cm for abdominal segments. An arctangent model with three free parameters A(p) = Am(1/2 + tan-1 [p-p0)/p1)/pi) explained over 99% of the variance in area with pressure for each aorta. Changes in compliance, characteristic impedance and propagation velocity are equally well described. Abdominal fits on the average appeared down scaled by a factor of 2 and shifted 20 mmHg towards lower pressures from paired thoracic (significant at p = 0.001).  相似文献   

16.
Supravalvular aortic stenosis (SVAS) is associated with decreased elastin and altered arterial mechanics. Mice with a single deletion in the elastin gene (ELN(+/-)) are models for SVAS. Previous studies have shown that elastin haploinsufficiency in these mice causes hypertension, decreased arterial compliance, and changes in arterial wall structure. Despite these differences, ELN(+/-) mice have a normal life span, suggesting that the arteries remodel and adapt to the decreased amount of elastin. To test this hypothesis, we performed in vitro mechanical tests on abdominal aorta, ascending aorta, and left common carotid artery from ELN(+/-) and wild-type (C57BL/6J) mice. We compared the circumferential and longitudinal stress-stretch relationships and residual strains. The circumferential stress-stretch relationship is similar between genotypes and changes <3% with longitudinal stretch at lengths within 10% of the in vivo value. At mean arterial pressure, the circumferential stress in the ascending aorta is higher in ELN(+/-) than in wild type. Although arterial pressures are higher, the increased number of elastic lamellae in ELN(+/-) arteries results in similar tension/lamellae compared with wild type. The longitudinal stress-stretch relationship is similar between genotypes for most arteries. Compared with wild type, the in vivo longitudinal stretch is lower in ELN(+/-) abdominal and carotid arteries and the circumferential residual strain is higher in ELN(+/-) ascending aorta. The increased circumferential residual strain brings the transmural strain distribution in ELN(+/-) ascending aorta close to wild-type values. The mechanical behavior of ELN(+/-) arteries is likely due to the reduced elastin content combined with adaptive remodeling during vascular development.  相似文献   

17.
The stress and strain states of the valve leaflets during fixation with glutaraldehyde affect their final mechanical parameters. Comparative studies of the stress-strain relationships of aortic valve leaflet strips from fresh, statically and dynamically fixed porcine and human valves were made. Static pressures of 5 mmHg, 16 mmHg, and 95 mmHg result in stress-strain relationships which are in a region between that of fresh porcine and fresh human leaflet strips in the circumferential direction, while they are far from that of fresh porcine tissue (larger strains) in the radial direction. Leaflet strips, fixed under dynamic loading between zero and a predefined maximum load, set at an early post-transition state, give parameters not significantly different from those of human valves.  相似文献   

18.
Intestinal stress-strain distributions are important determinants of intestinal function and are determined by the mechanical properties of the intestinal wall, the physiological loading conditions and the zero-stress state of the intestine. In this study the distribution of morphometric measures, residual circumferential strains and stress-strain relationships along the rat large intestine were determined in vitro. Segments from four parts of the large intestine were excised, closed at both ends, and inflated with pressures up to 2kPa. The outer diameter and length were measured. The zero-stress state was obtained by cutting rings of large intestine radially. The geometric configuration at the zero-stress state is of fundamental importance because it is the basic state with respect to which the physical stresses and strains are defined. The outer and inner circumferences, wall thickness and opening angle were measured from digitised images. Subsequently, residual strain and stress-strain distributions were calculated. The wall thickness and wall thickness-to-circumference ratio increased in the distal direction. The opening angle varied between approximately 40 and approximately 125 degrees with the highest values in the beginning of proximal colon (F=1.739, P<0.05). The residual strain at the inner surface was negative indicating that the mucosa-submucosal layers of the large intestine in no-load state are in compression. The four segments showed stress-strain distributions that were exponential. All segments were stiffer in longitudinal direction than in the circumferential direction (P<0.05). The transverse colon seemed stiffest both in the circumferential and longitudinal directions. In conclusion, significant variations were found in morphometric and biomechanical properties along the large intestine. The circumferential residual strains and passive elastic properties must be taken into account in studies of physiological problems in which the stress and strain are important, e.g. large intestinal bolus transport function.  相似文献   

19.
Right heart catheterization is often required to monitor intra-cardiac pressures in a number of disease states. Ultrasound contrast agents can produce pressure modulated subharmonic emissions that may be used to estimate right ventricular (RV) pressures. A technique based on subharmonic acoustic emissions from ultrasound contrast agents to track RV pressures noninvasively has been developed and its clinical potential evaluated. The subharmonic signals were obtained from the aorta, RV, and right atrium (RA) of five anesthetized closed-chest mongrel dogs using a SonixRP ultrasound scanner and PA4-2 phased array. Simultaneous pressure measurements were obtained using a 5-French solid state micromanometer tipped catheter. Initially, aortic subharmonic signals and systemic blood pressures were used to obtain a calibration factor in units of millimeters of mercury per decibel. This factor was combined with RA pressures (that can be obtained noninvasively) and the acoustic data from the RV to obtain RV pressure values. The individual calibration factors ranged from -2.0 to -4.0 mmHg/dB. The subharmonic signals tracked transient changes in the RV pressures within an error of 0.6 mmHg. Relative to the catheter pressures, the mean errors in estimating RV peak systolic and minimum diastolic pressures, and RV relaxation [isovolumic negative derivative of change in pressure over time (-dP/dt)] by use of the subharmonic signals, were -2.3 mmHg, -0.8 mmHg, and 2.9 mmHg/s, respectively. Overall, acoustic estimates of RV peak systolic and minimum diastolic pressures and RV relaxation were within 3.4 mmHg, 1.8 mmHg, and 5.9 mmHg/s, respectively, of the measured pressures. This pilot study demonstrates that subharmonic emissions from ultrasound contrast agents have the potential to noninvasively track in vivo RV pressures with errors below 3.5 mmHg.  相似文献   

20.
External reinforcement has been suggested for autologous vein grafts to address the mismatch of mechanical properties and fluid dynamics of graft and host vessel, a main factor for graft failure. A finite-element tool was developed to investigate the mechanical behaviour, in particular radial compliance, of knitted Nitinol meshes (internal diameter: 3.34 mm) with two different knit designs (even versus uneven circumferential loops) and three different wire thicknesses (0.05, 0.0635 and 0.075 mm) under physiological conditions. The Nitinol material parameters were obtained from experimental testing. The compliance predicted for the 80-120 mmHg physiological blood pressure range was 2.5, 0.9 and 0.6%/100 mmHg for the even loop design and 1.2, 0.5 and 0.5%/100 mmHg for the uneven loop design, for wire thicknesses of 0.05, 0.0635 and 0.075 mm. The highest stress, at 120 mmHg, was found in the even loop mesh with the thinnest wire to be 268 MPa, remaining 44.5% below the stress initiating stress-induced phase transformation. The maximum stress decreased to 132 and 91 MPa with increasing wire thickness of the same loop design. The uneven loop design exhibited maximum stress levels of 65.3%, 63.6% and 87.9% of the even loop values at 0.05, 0.0635 and 0.075 mm wire thickness. The maximum strain of 0.7%, at 120 mmHg, remained un-critical considering a typical high-cycle recoverable strain of 2%. It was demonstrated that the numerical approach developed was feasible of effectively evaluating design variations of knitted Nitinol meshes towards vein graft behaviour equivalent to arterial mechanics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号