首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
2.

Introduction

Availability of large cohorts of samples with related metadata provides scientists with extensive material for studies. At the same time, recent development of modern high-throughput ‘omics’ technologies, including metabolomics, has resulted in the potential for analysis of large sample sizes. Representative subset selection becomes critical for selection of samples from bigger cohorts and their division into analytical batches. This especially holds true when relative quantification of compound levels is used.

Objectives

We present a multivariate strategy for representative sample selection and integration of results from multi-batch experiments in metabolomics.

Methods

Multivariate characterization was applied for design of experiment based sample selection and subsequent subdivision into four analytical batches which were analyzed on different days by metabolomics profiling using gas-chromatography time-of-flight mass spectrometry (GC–TOF–MS). For each batch OPLS-DA® was used and its p(corr) vectors were averaged to obtain combined metabolic profile. Jackknifed standard errors were used to calculate confidence intervals for each metabolite in the average p(corr) profile.

Results

A combined, representative metabolic profile describing differences between systemic lupus erythematosus (SLE) patients and controls was obtained and used for elucidation of metabolic pathways that could be disturbed in SLE.

Conclusion

Design of experiment based representative sample selection ensured diversity and minimized bias that could be introduced at this step. Combined metabolic profile enabled unified analysis and interpretation.
  相似文献   

3.

Introduction

Data processing is one of the biggest problems in metabolomics, given the high number of samples analyzed and the need of multiple software packages for each step of the processing workflow.

Objectives

Merge in the same platform the steps required for metabolomics data processing.

Methods

KniMet is a workflow for the processing of mass spectrometry-metabolomics data based on the KNIME Analytics platform.

Results

The approach includes key steps to follow in metabolomics data processing: feature filtering, missing value imputation, normalization, batch correction and annotation.

Conclusion

KniMet provides the user with a local, modular and customizable workflow for the processing of both GC–MS and LC–MS open profiling data.
  相似文献   

4.

Introduction

Collecting feces is easy. It offers direct outcome to endogenous and microbial metabolites.

Objectives

In a context of lack of consensus about fecal sample preparation, especially in animal species, we developed a robust protocol allowing untargeted LC-HRMS fingerprinting.

Methods

The conditions of extraction (quantity, preparation, solvents, dilutions) were investigated in bovine feces.

Results

A rapid and simple protocol involving feces extraction with methanol (1/3, M/V) followed by centrifugation and a step filtration (10 kDa) was developed.

Conclusion

The workflow generated repeatable and informative fingerprints for robust metabolome characterization.
  相似文献   

5.

Introduction

Infiltrating gliomas are primary brain tumors that express significant biological and clinical heterogeneity in adults, which complicates their treatment and prognosis. Characterization of tumor subtypes using spectroscopic analysis may assist in predicting malignant transformation and quantification of response to therapy.

Study objective

To implement an automated algorithm for classification of metabolomic profiles for the classification of glioma pathological grades and the prediction of malignant progression using spectra obtained by high-resolution magic angle spinning (HR-MAS) spectroscopy of patient-derived tissue samples.

Methods

237 image-guided tissue samples were obtained from 152 patients who underwent surgery for newly diagnosed or recurrent glioma and analyzed via HR-MAS spectroscopy. Orthogonal projection to latent structures discriminant analysis was used as a classifier and the variable-influence-on-projection values were evaluated to identify signature spectral regions.

Results

The accuracy of classifiers developed for discriminating glioma subtypes was 68% for newly diagnosed grade II versus III samples; 86 and 92% for new and recurrent grade III versus IV, respectively; 95% for newly diagnosed grade II versus IV; and 88% for recurrent grade II versus IV lesions. Classifiers distinguished between samples from newly diagnosed vs. recurrent lesions with an accuracy of 78% for grade III and 99% for grade IV glioma.

Conclusion

Classifying metabolomic profiles for new and recurrent glioma without prior assumptions regarding spectral components identified candidate in vivo biomarkers for use in assessing changes that are likely to impact treatment decisions.
  相似文献   

6.

Background

Human cancers are complex ecosystems composed of cells with distinct molecular signatures. Such intratumoral heterogeneity poses a major challenge to cancer diagnosis and treatment. Recent advancements of single-cell techniques such as scRNA-seq have brought unprecedented insights into cellular heterogeneity. Subsequently, a challenging computational problem is to cluster high dimensional noisy datasets with substantially fewer cells than the number of genes.

Methods

In this paper, we introduced a consensus clustering framework conCluster, for cancer subtype identification from single-cell RNA-seq data. Using an ensemble strategy, conCluster fuses multiple basic partitions to consensus clusters.

Results

Applied to real cancer scRNA-seq datasets, conCluster can more accurately detect cancer subtypes than the widely used scRNA-seq clustering methods. Further, we conducted co-expression network analysis for the identified melanoma subtypes.

Conclusions

Our analysis demonstrates that these subtypes exhibit distinct gene co-expression networks and significant gene sets with different functional enrichment.
  相似文献   

7.

Background

An important feature in many genomic studies is quality control and normalization. This is particularly important when analyzing epigenetic data, where the process of obtaining measurements can be bias prone. The GAW20 data was from the Genetics of Lipid Lowering Drugs and Diet Network (GOLDN), a study with multigeneration families, where DNA cytosine-phosphate-guanine (CpG) methylation was measured pre- and posttreatment with fenofibrate. We performed quality control assessment of the GAW20 DNA methylation data, including normalization, assessment of batch effects and detection of sample swaps.

Results

We show that even after normalization, the GOLDN methylation data has systematic differences pre- and posttreatment. Through investigation of (a) CpGs sites containing a single nucleotide polymorphism, (b) the stability of breeding values for methylation across time points, and (c) autosomal gender-associated CpGs, 13 sample swaps were detected, 11 of which were posttreatment.

Conclusions

This paper demonstrates several ways to perform quality control of methylation data in the absence of raw data files and highlights the importance of normalization and quality control of the GAW20 methylation data from the GOLDN study.
  相似文献   

8.

Introduction

Data sharing is being increasingly required by journals and has been heralded as a solution to the ‘replication crisis’.

Objectives

(i) Review data sharing policies of journals publishing the most metabolomics papers associated with open data and (ii) compare these journals’ policies to those that publish the most metabolomics papers.

Methods

A PubMed search was used to identify metabolomics papers. Metabolomics data repositories were manually searched for linked publications.

Results

Journals that support data sharing are not necessarily those with the most papers associated to open metabolomics data.

Conclusion

Further efforts are required to improve data sharing in metabolomics.
  相似文献   

9.
10.

Introduction

Liquid chromatography-mass spectrometry (LC-MS) is a commonly used technique in untargeted metabolomics owing to broad coverage of metabolites, high sensitivity and simple sample preparation. However, data generated from multiple batches are affected by measurement errors inherent to alterations in signal intensity, drift in mass accuracy and retention times between samples both within and between batches. These measurement errors reduce repeatability and reproducibility and may thus decrease the power to detect biological responses and obscure interpretation.

Objective

Our aim was to develop procedures to address and correct for within- and between-batch variability in processing multiple-batch untargeted LC-MS metabolomics data to increase their quality.

Methods

Algorithms were developed for: (i) alignment and merging of features that are systematically misaligned between batches, through aggregating feature presence/missingness on batch level and combining similar features orthogonally present between batches; and (ii) within-batch drift correction using a cluster-based approach that allows multiple drift patterns within batch. Furthermore, a heuristic criterion was developed for the feature-wise choice of reference-based or population-based between-batch normalisation.

Results

In authentic data, between-batch alignment resulted in picking 15 % more features and deconvoluting 15 % of features previously erroneously aligned. Within-batch correction provided a decrease in median quality control feature coefficient of variation from 20.5 to 15.1 %. Algorithms are open source and available as an R package (‘batchCorr’).

Conclusions

The developed procedures provide unbiased measures of improved data quality, with implications for improved data analysis. Although developed for LC-MS based metabolomics, these methods are generic and can be applied to other data suffering from similar limitations.
  相似文献   

11.

Background

The aim was to improve upon an existing blood-based colorectal cancer (CRC) test directed to high-risk symptomatic patients, by developing a new CRC classifier to be used with a new test embodiment. The new test uses a robust assay format—electrochemiluminescence immunoassays—to quantify protein concentrations. The aim was achieved by building and validating a CRC classifier using concentration measures from a large sample set representing a true intent-to-test (ITT) symptomatic population.

Methods

4435 patient samples were drawn from the Endoscopy II sample set. Samples were collected at seven hospitals across Denmark between 2010 and 2012 from subjects with symptoms of colorectal neoplasia. Colonoscopies revealed the presence or absence of CRC. 27 blood plasma proteins were selected as candidate biomarkers based on previous studies. Multiplexed electrochemiluminescence assays were used to measure the concentrations of these 27 proteins in all 4435 samples. 3066 patients were randomly assigned to the Discovery set, in which machine learning was used to build candidate classifiers. Some classifiers were refined by allowing up to a 25% indeterminate score range. The classifier with the best Discovery set performance was successfully validated in the separate Validation set, consisting of 1336 samples.

Results

The final classifier was a logistic regression using ten predictors: eight proteins (A1AG, CEA, CO9, DPPIV, MIF, PKM2, SAA, TFRC), age, and gender. In validation, the indeterminate rate of the new panel was 23.2%, sensitivity/specificity was 0.80/0.83, PPV was 36.5%, and NPV was 97.1%.

Conclusions

The validated classifier serves as the basis of a new blood-based CRC test for symptomatic patients. The improved performance, resulting from robust concentration measures across a large sample set mirroring the ITT population, renders the new test the best available for this population. Results from a test using this classifier can help assess symptomatic patients’ CRC risk, increase their colonoscopy compliance, and manage next steps in their care.
  相似文献   

12.

Context

Patients with chronic fatigue syndrome and those with orthostatic intolerance share many symptoms, yet questions exist as to whether CFS patients have physiological evidence of orthostatic intolerance.

Objective

To determine if some CFS patients have increased rates of orthostatic hypotension, hypertension, tachycardia, or hypocapnia relative to age-matched controls.

Design

Assess blood pressure, heart rate, respiratory rate, end tidal CO2 and visual analog scales for orthostatic symptoms when supine and when standing for 8 minutes without moving legs.

Setting

Referral practice and research center.

Participants

60 women and 15 men with CFS and 36 women and 4 men serving as age matched controls with analyses confined to 62 patients and 35 controls showing either normal orthostatic testing or a physiological abnormal test.

Main outcome measures

Orthostatic tachycardia; orthostatic hypotension; orthostatic hypertension; orthostatic hypocapnia or combinations thereof.

Results

CFS patients had higher rates of abnormal tests than controls (53% vs 20%, p < .002), but rates of orthostatic tachycardia, orthostatic hypotension, and orthostatic hypertension did not differ significantly between patients and controls (11.3% vs 5.7%, 6.5% vs 2.9%, 19.4% vs 11.4%, respectively). In contrast, rates of orthostatic hypocapnia were significantly higher in CFS than in controls (20.6% vs 2.9%, p < .02). This CFS group reported significantly more feelings of illness and shortness of breath than either controls or CFS patients with normal physiological tests.

Conclusion

A substantial number of CFS patients have orthostatic intolerance in the form of orthostatic hypocapnia. This allows subgrouping of patients with CFS and thus reduces patient pool heterogeneity engendered by use of a clinical case definition.
  相似文献   

13.

Introduction

Mass spectrometry imaging (MSI) experiments result in complex multi-dimensional datasets, which require specialist data analysis tools.

Objectives

We have developed massPix—an R package for analysing and interpreting data from MSI of lipids in tissue.

Methods

massPix produces single ion images, performs multivariate statistics and provides putative lipid annotations based on accurate mass matching against generated lipid libraries.

Results

Classification of tissue regions with high spectral similarly can be carried out by principal components analysis (PCA) or k-means clustering.

Conclusion

massPix is an open-source tool for the analysis and statistical interpretation of MSI data, and is particularly useful for lipidomics applications.
  相似文献   

14.

Introduction

Botanicals containing iridoid and phenylethanoid/phenylpropanoid glycosides are used worldwide for the treatment of inflammatory musculoskeletal conditions that are primary causes of human years lived with disability, such as arthritis and lower back pain.

Objectives

We report the analysis of candidate anti-inflammatory metabolites of several endemic Scrophularia species and Verbascum thapsus used medicinally by peoples of North America.

Methods

Leaves, stems, and roots were analyzed by ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) and partial least squares-discriminant analysis (PLS-DA) was performed in MetaboAnalyst 3.0 after processing the datasets in Progenesis QI.

Results

Comparison of the datasets revealed significant and differential accumulation of iridoid and phenylethanoid/phenylpropanoid glycosides in the tissues of the endemic Scrophularia species and Verbascum thapsus.

Conclusions

Our investigation identified several species of pharmacological interest as good sources for harpagoside and other important anti-inflammatory metabolites.
  相似文献   

15.

Background

Centrifugation is an indispensable procedure for plasma sample preparation, but applied conditions can vary between labs.

Aim

Determine whether routinely used plasma centrifugation protocols (1500×g 10 min; 3000×g 5 min) influence non-targeted metabolomic analyses.

Methods

Nuclear magnetic resonance spectroscopy (NMR) and High Resolution Mass Spectrometry (HRMS) data were evaluated with sparse partial least squares discriminant analyses and compared with cell count measurements.

Results

Besides significant differences in platelet count, we identified substantial alterations in NMR and HRMS data related to the different centrifugation protocols.

Conclusion

Already minor differences in plasma centrifugation can significantly influence metabolomic patterns and potentially bias metabolomics studies.
  相似文献   

16.

Background

The purpose of this study is to explore the potential of phase contrast imaging to detect fibrotic progress in its early stage; to investigate the feasibility of texture features for quantified diagnosis of liver fibrosis; and to evaluate the performance of back propagation (BP) neural net classifier for characterization and classification of liver fibrosis.

Methods

Fibrous mouse liver samples were imaged by X-ray phase contrast imaging, nine texture measures based on gray-level co-occurrence matrix were calculated and the feasibility of texture features in the characterization and discrimination of liver fibrosis at early stages was investigated. Furthermore, 36 or 18 features were applied to the input of BP classifier; the classification performance was evaluated using receiver operating characteristic curve.

Results

The phase contrast images displayed a vary degree of texture pattern from normal to severe fibrosis stages. The BP classifier could distinguish liver fibrosis among normal, mild, moderate and severe stages; the average accuracy was 95.1% for 36 features, and 91.1% for 18 features.

Conclusion

The study shows that early stages of liver fibrosis can be discriminated by the morphological features on the phase contrast images. BP network model based on combination of texture features is demonstrated effective for staging liver fibrosis.
  相似文献   

17.

Background

In recent years the visualization of biomagnetic measurement data by so-called pseudo current density maps or Hosaka-Cohen (HC) transformations became popular.

Methods

The physical basis of these intuitive maps is clarified by means of analytically solvable problems.

Results

Examples in magnetocardiography, magnetoencephalography and magnetoneurography demonstrate the usefulness of this method.

Conclusion

Hardware realizations of the HC-transformation and some similar transformations are discussed which could advantageously support cross-platform comparability of biomagnetic measurements.
  相似文献   

18.

Purpose

This discussion article aims to highlight two problematic aspects in the International Reference Life Cycle Data System (ILCD) Handbook: its guidance to the choice between attributional and consequential modeling and to the choice between average and marginal data as input to the life cycle inventory (LCI) analysis.

Methods

We analyze the ILCD guidance by comparing different statements in the handbook with each other and with previous research in this area.

Results and discussion

We find that the ILCD handbook is internally inconsistent when it comes to recommendations on how to choose between attributional and consequential modeling. We also find that the handbook is inconsistent with much of previous research in this matter, and also in the recommendations on how to choose between average and marginal data in the LCI.

Conclusions

Because of the inconsistencies in the ILCD handbook, we recommend that the handbook be revised.
  相似文献   

19.

Introduction

Allograft rejection is still an important complication after kidney transplantation. Currently, monitoring of these patients mostly relies on the measurement of serum creatinine and clinical evaluation. The gold standard for diagnosing allograft rejection, i.e. performing a renal biopsy is invasive and expensive. So far no adequate biomarkers are available for routine use.

Objectives

We aimed to develop a urine metabolite constellation that is characteristic for acute renal allograft rejection.

Methods

NMR-Spectroscopy was applied to a training cohort of transplant recipients with and without acute rejection.

Results

We obtained a metabolite constellation of four metabolites that shows promising performance to detect renal allograft rejection in the cohorts used (AUC of 0.72 and 0.74, respectively).

Conclusion

A metabolite constellation was defined with the potential for further development of an in-vitro diagnostic test that can support physicians in their clinical assessment of a kidney transplant patient.
  相似文献   

20.

Introduction

Metabolome analysis is complicated by the continuous dynamic changes of metabolites in vivo and ex vivo. One of the main challenges in metabolomics is the robustness and reproducibility of results, partially driven by pre-analytical variations.

Objectives

The objective of this study was to analyse the impact of pre-centrifugation time and temperature, and to determine a quality control marker in plasma samples.

Methods

Plasma metabolites were measured by gas chromatography-mass spectrometry (GC–MS) and analysed with the MetaboliteDetector software. The metabolites, which were the most labile to pre-analytical variations, were further measured by enzymatic assays. A score was calculated for their use as quality control markers.

Results

The pre-centrifugation temperature was shown to be critical in the stability of plasma samples and had a significant impact on metabolite concentration profiles. In contrast, pre-centrifugation delay had only a minor impact. Based on the results of this study, whole blood should be kept on wet ice and centrifuged within maximum 3 h as a prerequisite for preparing EDTA plasma samples fit for the purpose of metabolome analysis.

Conclusions

We have established a novel blood sample quality control marker, the LacaScore, based on the ascorbic acid to lactic acid ratio in plasma, which can be used as an indicator of the blood pre-centrifugation conditions, and hence the suitability of the sample for metabolome analyses. This method can be applied in research institutes and biobanks, enabling assessment of the quality of their plasma sample collections.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号