1.
Infrared and Raman spectroscopy allow direct spectral analysis of the solid-phase, thus avoiding the tedious cleavage of compounds from the solid support. With diagnostic bands in starting materials or products, infrared and Raman spectroscopy are efficient in monitoring each reaction step directly on the solid phase. Consequently, infrared and Raman spectroscopy have evolved as the premier analytical methodology for direct analysis on the solid support. While infrared transmission spectroscopy is a general analytical method for resin samples, internal reflection spectroscopy is especially suited for solid polymer substrates known as "pins" or "crowns." Single bead analysis is done best by infrared microspectroscopy, whereas photoacoustic spectroscopy allows totally nondestructive analysis of resin samples. With an automated accessory, diffuse reflection spectroscopy provides a method for high throughput on-bead monitoring of solid-phase reactions. Providing identification based on molecular structure, HPLC-FTIR is, therefore, complementary to LC-MS. Additionally, Raman spectroscopy as a complement to infrared spectroscopy can be applied to resin samples and-using a Raman microscope-to single beads. Fluorometry as an extremely sensitive spectroscopic detection method allows rapid quantification of organic reactions directly on the resin.  相似文献   

2.
The adaptation of diverse organic reactions to solid supports requires significant reaction optimization efforts. A convenient on-support analytical method functionally similar to TLC in solution chemistry is very advantageous. As a TLC-equivalent method, the single bead FTIR is a simple, sensitive, fast, and convenient analytical method to monitor SPOS without stopping the reaction or cleaving the product. As with TLC, single bead FTIR provides a wide range of information such as qualitative assessment, quantitative determination, and reaction kinetics. Studies with the single bead FTIR have not only provided a tool for daily monitoring of the solid-phase reactions, but a way to understand the properties of polymer-bound substrate and the nature of polymer-supported organic reactions. It has assisted in the selection of a wide range of reaction conditions rapidly for SPOS in the rehearsal phase of combinatorial chemistry. Due to its convenience and efficiency, FTIR internal reflection spectroscopy has evolved as a useful analytical methodology for monitoring of combinatorial chemistry reactions directly on polymer surface.  相似文献   

3.
A semi‐automated technique for massive parallel solid‐phase organic synthesis based on a “split only” strategy is described. Two different types of purpose‐oriented reaction vessels are used. The initial steps are performed in domino blocks, and the resin‐bound intermediates then split into wells of a micro plate for the last combinatorial step. The domino block is a reaction block for manual and semi‐automatic parallel solid‐phase organic synthesis that simplifies liquid exchange and integrates common synthetic steps. The synthesis in micro plates does not use any filter for separation of resin beads from the supernatant liquid, and allows high throughput parallel synthesis on solid phase to be performed. This technique, documented on examples of diverse disubstituted benzenes, includes the use of gaseous cleavage in the last synthetic step and allows the synthesis of thousands of compounds per day in mg quantities. © 1999 John Wiley & Sons, Inc. Biotechnol Bioeng (Comb Chem) 61:135–141, 1998/1999.  相似文献   

4.
In recent years, the diagnosis of brain tumors has been investigated with attenuated total reflection‐Fourier transform infrared (ATR‐FTIR) spectroscopy on dried human serum samples to eliminate spectral interferences of the water component, with promising results. This research evaluates ATR‐FTIR on both liquid and air‐dried samples to investigate “digital drying” as an alternative approach for the analysis of spectra obtained from liquid samples. Digital drying approaches, consisting of water subtraction and least‐squares method, have demonstrated a greater random forest (RF) classification performance than the air‐dried spectra approach when discriminating cancer vs control samples, reaching sensitivity values higher than 93.0% and specificity values higher than 83.0%. Moreover, quantum cascade laser infrared (QCL‐IR) based spectroscopic imaging is utilized on liquid samples to assess the implications of a deep‐penetration light source on disease classification. The RF classification of QCL‐IR data has provided sensitivity and specificity amounting to 85.1% and 75.3% respectively.  相似文献   

5.
A rapid and reliable intraoperative diagnostic technique to support clinical decisions was developed using Fourier‐transform infrared (FTIR) spectroscopy. Twenty‐six fresh tissue samples were collected intraoperatively from patients undergoing gynecological surgeries. Frozen section (FS) histopathology aimed to discriminate between malignant and benign tumors was performed, and attenuated total reflection (ATR) FTIR spectra were collected from these samples. Digital dehydration and principal component analysis and linear discriminant analysis (PCA‐LDA) models were developed to classify samples into malignant and benign groups. Two validation schemes were employed: k‐fold and “leave one out.” FTIR absorption spectrum of a fresh tissue sample was obtained in less than 5 minutes. The fingerprint spectral region of malignant tumors was consistently different from that of benign tumors. The PCA‐LDA discrimination model correctly classified the samples into malignant and benign groups with accuracies of 96% and 93% for the k‐fold and “leave one out” validation schemes, respectively. We showed that a simple tissue preparation followed by ATR‐FTIR spectroscopy provides accurate means for very rapid tumor classification into malignant and benign gynecological tumors. With further development, the proposed method has high potential to be used as an adjunct to the intraoperative FS histopathology technique.  相似文献   

6.
Microwave‐assisted (MW) reactions are of special interest to the chemical community due to faster reaction times, cleaner reactions and higher product yields. The adaptation of MW to solid phase peptide synthesis resulted in spectacular syntheses of difficult peptides. In the case of Merrifield support, used frequently in synthesis of special peptides, the conditions used in product cleavage are not compatible with off‐resin monitoring of the reaction progress. The application of MW irradiation in product removal from Merrifield resin using trifluoroacetic acid (TFA) was investigated using model tetrapeptides and the effects were compared with standard trifluoromethanesulphonic acid (TFMSA) cleavage using elemental analysis as well as chromatographic (HPLC) and spectroscopic (IR) methods. The deprotection of benzyloxycarbonyl and benzyl groups in synthetic bioactive peptides was analyzed using LC‐MS and MS/MS experiments. In a 5 min microwave‐assisted TFA reaction at low temperature, the majority of product is released from the resin, making the analytical scale MW‐assisted procedure a method of choice in monitoring the reactions carried out on Merrifield resin due to the short reaction time and compatibility with HPLC and ESI‐MS conditions. Copyright © 2009 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

7.
Vibrational spectroscopic techniques such as near‐infrared (NIR), Fourier transform infrared (FTIR), and Raman spectroscopy are valuable diagnostic tools that can be used to elucidate comprehensive structural information of numerous biological samples. In this review article, we have highlighted the advantages of nanotechnology and biophotonics in conjunction with vibrational spectroscopic techniques in order to understand the various aspects of new kind of synthetic biopolymers termed as polyethylene glycol (PEG)ylated lipids. In contrast to conventional phospholipids, these novel lipids spontaneously form liposomes or nanovesicles upon hydration, without the supply of external activation energy. The amphiphiles considered in this study differ in their hydrophobic acyl chain length and contain different units of PEG hydrophilic headgroups. We have further explored the thermotropic phase behaviors and associated changes in the conformational order/disorder of such lipids by using variable‐temperature FTIR and Raman spectroscopy. Phase transition temperature profiles and correlation between various spectral indicators have been identified by either monitoring the shifts in the vibrational peak positions or plotting vibrational peak intensity ratios in the C? H stretching region as a function of temperature. To supplement our observations of phase transformations, a thermodynamic approach known as differential scanning calorimetry (DSC) has been applied and revealed a good agreement with the infrared and Raman spectroscopic data. Finally, the investigation of thermal properties of lipids is extremely crucial for numerous purposes, thus the results obtained in this work may find application in a wide variety of studies including the development of PEGylated lipid based drug and substances delivery vehicles. © 2010 Wiley Periodicals, Inc. Biopolymers 93: 403–417, 2010. This article was originally published online as an accepted preprint. The “Published Online” date corresponds to the preprint version. You can request a copy of the preprint by emailing the Biopolymers editorial office at biopolymers@wiley.com  相似文献   

8.
Multiple‐internal‐reflection infrared spectroscopy allows for the study of thin‐film amorphous silicon electrodes in situ and in operando, in conditions typical of those used in Li‐ion batteries. It brings an enhanced sensitivity, and the attenuated‐total‐reflection geometry allows for the extraction of quantitative information. When electrodes are cycled in representative electrolytes, the simultaneously recorded infrared spectra give an insight into the solid/electrolyte interphase (SEI) composition. They also unravel the dynamic behavior of this SEI layer by quantitatively assessing its thickness, which increases during silicon lithiation and partially decreases during delithiation. Li‐ion solvation effects in the vicinity of the electrode indicate that lithium incorporation in the solid phase is the rate‐determining step of the electrochemical processes during lithiation. The lithiation of the active material also results in the irreversible consumption of a large quantity of hydrogen in the pristine material. Finally, the evolution of the electronic absorption of the electrode material suggests that lithium diffusion is much easier after the first lithiation than in the pristine material. Therefore, in situ Fourier‐transform infrared spectroscopy performed in a well‐suited configuration efficiently extracts original and quantitative pieces of information on the surface and bulk phenomena affecting Li‐ion electrodes during their operation in realistic conditions.  相似文献   

9.
A core‐shell type polymer support for solid‐phase peptide synthesis has been developed for high coupling efficiency of peptides and versatile applications such as on‐bead bioassays. Although various kinds of polymer supports have been developed, they have their own drawbacks including poor accessibility of reagents and incompatibility in aqueous solution. In this paper, we prepared hydrophilic tri(ethylene glycol) (TEG) grafted core‐shell type polymer supports (TEG SURE) for efficient solid‐phase peptide synthesis and on‐bead bioassays. TEG SURE was prepared by grafting TEG derivative on the surface of AM PS resin via biphasic diffusion control method and subsequent acetylation of amine groups which are located at the core region of AM PS resin. The performance of TEG SURE was evaluated by synthesizing several peptides. Three points can be highlighted: (1) easy control of loading level of TEG, (2) improved efficiency of peptide synthesis compared with the conventional resins, and (3) applicability of on‐bead bioassays.  相似文献   

10.
Several non‐invasive Raman spectroscopy‐based assays have been reported for rapid and sensitive detection of pathogens. We developed a novel statistical model for the detection of RNA viruses in saliva, based on an unbiased selection of a set of 65 Raman spectral features that mostly attribute to the RNA moieties, with a prediction accuracy of 91.6% (92.5% sensitivity and 88.8% specificity). Furthermore, to minimize variability and automate the downstream analysis of the Raman spectra, we developed a GUI‐based analytical tool “RNA Virus Detector (RVD).” This conceptual framework to detect RNA viruses in saliva could form the basis for field application of Raman Spectroscopy in managing viral outbreaks, such as the ongoing COVID‐19 pandemic. ( http://www.actrec.gov.in/pi-webpages/AmitDutt/RVD/RVD.html ).  相似文献   

11.
Near‐infrared spectroscopy is considered to be one of the most promising spectroscopic techniques for upstream bioprocess monitoring and control. Traditionally the nature of near‐infrared spectroscopy has demanded multivariate calibration models to relate spectral variance to analyte concentrations. The resulting analytical measurements have proven unreliable for the measurement of metabolic substrates for bioprocess batches performed outside the calibration process. This paper presents results of an innovative near‐infrared spectroscopic monitor designed to follow the concentrations of glycerol and methanol, as well as biomass, in real time and continuously during the production of a monoclonal antibody by a Pichia pastoris high cell density process. A solid state instrumental design overcomes the ruggedness limitations of conventional interferometer‐based spectrometers. Accurate monitoring of glycerol, methanol, and biomass is demonstrated over 274 days postcalibration. In addition, the first example of feedback control to maintain constant methanol concentrations, as low as 1 g/L, is presented. Postcalibration measurements over a 9‐month period illustrate a level of reliability and robustness that promises its adoption for online bioprocess monitoring throughout product development, from early laboratory research and development to pilot and manufacturing scale operation. © 2014 American Institute of Chemical Engineers Biotechnol. Prog., 30:749–759, 2014  相似文献   

12.
Herein, a technique to analyze air‐dried kidney tissue impression smears by means of attenuated total reflection infrared (ATR‐IR) spectroscopy is presented. Spectral tumor markers—absorption bands of glycogen—are identified in the ATR‐IR spectra of the kidney tissue smear samples. Thin kidney tissue cryo‐sections currently used for IR spectroscopic analysis lack such spectral markers as the sample preparation causes irreversible molecular changes in the tissue. In particular, freeze‐thaw cycle results in degradation of the glycogen and reduction or complete dissolution of its content. Supervised spectral classification was applied to the recorded spectra of the smears and the test spectra were classified with a high accuracy of 92% for normal tissue and 94% for tumor tissue, respectively. For further development, we propose that combination of the method with optical fiber ATR probes could potentially be used for rapid real‐time intra‐operative tissue analysis without interfering with either the established protocols of pathological examination or the ordinary workflow of operating surgeon. Such approach could ensure easier transition of the method to clinical applications where it may complement the results of gold standard histopathology examination and aid in more precise resection of kidney tumors.   相似文献   

13.
Within the framework of process analytical technology, infrared spectroscopy (IR) has been used for characterization of biopharmaceutical production processes. Although noninvasive attenuated total reflection (ATR) spectroscopy can be regarded as gold standard within IR‐based process analytics, simpler and more cost‐effective mid‐infrared (MIR) instruments might improve acceptability of this technique for high‐level monitoring of small scale experiments as well as for academia where financial restraints impede the use of costly equipment. A simple and straightforward at‐line mid‐IR instrument was used to monitor cell viability parameters, activity of lactate dehydrogenase (LDH), amount of secreted antibody, and concentration of glutamate and lactate in a Chinese hamster ovary cell culture process, applying multivariate prediction models, including only 25–28 calibration samples per model. Glutamate amount could be predicted with high accuracy (R2 0.91 for independent test‐set) while antibody concentration achieved good prediction for concentrations >0.4 mg L?1. Prediction of LDH activity was accurate except for the low activity regime. The model for lactate monitoring was only moderately good and requires improvements. Relative cell viability between 20 and 95% could be predicted with low error (8.82%) in comparison to reference methods. An initial model for determining the number of nonviable cells displayed only acceptable accuracy and requires further improvement. In contrast, monitoring of viable cell number showed better accuracy than previously published ATR‐based results. These results prove the principal suitability of less sophisticated MIR instruments to monitor multiple parameters in biopharmaceutical production with relatively low investments and rather fast calibration procedures. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 31:578–584, 2015  相似文献   

14.
The mechanism of the interaction between bovine serum albumin (BSA) and desvenlafaxine was studied using fluorescence, ultraviolet absorption, 3‐dimensional fluorescence spectroscopy, circular dichroism, synchronous fluorescence spectroscopy, cyclic voltametry, differential scanning calorimetry, and attenuated total reflection–Fourier transform infrared spectroscopic techniques under physiological condition at pH 7.4. Stern‐Volmer calculations authenticate the fluorescence of BSA that was quenched by desvenlafaxine in a collision quenching mode. The fluorescence quenching method was used to evaluate number of binding sites “n” and binding constant K A that were measured, and various thermodynamic parameters were evaluated at different temperatures by using the van't Hoff equation and differential scanning calorimetry technique, which indicated a spontaneous and hydrophobic interaction between BSA and desvenlafaxine. According to the Förster theory we calculate the distance between the donor, BSA and acceptor, desvenlafaxine molecules. Furthermore, circular dichroism and attenuated total reflection–Fourier transform infrared spectroscopy indicate nominal changes in the secondary structure of the protein.  相似文献   

15.
We demonstrate a novel bio‐spectroscopic technique, “simultaneous Raman/GFP microspectroscopy”. It enables organelle specific Raman microspectroscopy of living cells. Fission yeast, Schizosaccharomyces pombe, whose mitochondria are green fluorescence protein (GFP) labeled, is used as a test model system. Raman excitation laser and GFP excitation light irradiate the sample yeast cells simultaneously. GFP signal is monitored in the anti‐Stokes region where interference from Raman scattering is negligibly small. Of note, 13 568 Raman spectra measured from different points of 19 living yeast cells are categorized according to their GFP fluorescence intensities, with the use of a two‐component multivariate curve resolution with alternate least squares (MCR‐ALS) analysis in the anti‐Stokes region. This categorization allows us to know whether or not Raman spectra are taken from mitochondria. Raman spectra specific to mitochondria are obtained by an MCR‐ALS analysis in the Stokes region of 1389 strongly GFP positive spectra. Two mitochondria specific Raman spectra have been obtained. The first one is dominated by protein Raman bands and the second by lipid Raman bands, being consistent with the known molecular composition of mitochondria. In addition, the second spectrum shows a strong band of ergosterol at 1602 cm?1, previously reported as “Raman spectroscopic signature of life of yeast.”  相似文献   

16.
The non‐destructive and label‐free monitoring of extracellular matrix (ECM) remodeling and degradation processes is a great challenge. Raman spectroscopy is a non‐contact method that offers the possibility to analyze ECM in situ without the need for tissue processing. Here, we employed Raman spectroscopy for the detection of heart valve ECM, focusing on collagen fibers. We screened the leaflets of porcine aortic valves either directly after dissection or after treatment with collagenase. By comparing the fingerprint region of the Raman spectra of control and treated tissues (400–1800 cm–1), we detected no significant differences based on Raman shifts; however, we found that increasing collagen degradation translated into decreasing Raman signal intensities. After these proof‐of‐principal experiments, we compared Raman spectra of native and cryopreserved valve tissues and revealed that the signal intensities of the frozen samples were significantly lower compared to those of native tissues, similar to the data seen in the enzymatically‐degraded tissues. In conclusion, our data demonstrate that Raman microscopy is a promising, non‐destructive and non‐contact tool to probe ECM state in situ. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

17.
Methylation status plays important roles in the regulation of gene expression and significantly influences the dynamics, bending and flexibility of DNA. The aim of this study was to determine whether attenuated total reflection Fourier‐transform infrared (ATR‐FTIR) or Raman spectroscopy with subsequent multivariate analysis could determine methylation patterning in oligonucleotides variously containing 5‐methylcytosine, cytosine and guanine bases. Applied to Low‐E reflective glass slides, 10 independent spectral acquisitions were acquired per oligonucleotide sample. Resultant spectra were baseline‐corrected and vector normalised over the 1750 cm–1–760 cm–1 (for ATR‐FTIR spectroscopy) or the 1750 cm–1–600 cm–1 (for Raman spectroscopy) regions. Data were then analysed using principal component analysis (PCA) coupled with linear discriminant analysis (LDA). Exploiting this approach, biomolecular signatures enabling sensitive and specific discrimination of methylation patterning were derived. For DNA sequence and methylation analysis, this approach has the potential to be an important tool, especially when material is scarce. (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

18.
Infrared spectroscopy is a rapid, easy‐to‐operate, label‐free and therefore cost‐effective technique. Many studies performed on biofluids (eg, serum, plasma, urine, sputum, bile and cerebrospinal fluid) have demonstrated its promising application as a clinical diagnostic tool. Given all these characteristics, infrared spectroscopy appears to be an ideal candidate to be implemented into the clinics. However, before considering its translation, a clear effort is needed to standardise protocols for biofluid spectroscopic analysis. To reach this goal, careful investigations to identify and track errors that can occur during the pre‐analytical phase is a crucial step. Here, we report for the first time, results of investigations into pre‐analytical factors that can affect the quality of the spectral data acquired on serum and plasma, such as the impact of long‐term freezing time storage of samples as well as the month‐to‐month reproducibility of the spectroscopic analysis. The spectral data discrimination has revealed to be majorly impacted by a residual water content variation in serum and plasma dried samples.   相似文献   

19.
Urinary stones can be readily disintegrated by Holmium:YAG laser (Holmium laser lithotripsy), resulting in a mixture of small stone dust particles, which will spontaneously evacuate with urine and larger residual fragments (RF) requiring mechanical retrieval. Differences between fragments and dust have not been well characterized. Also, it remains unknown how the recently introduced “Moses technology” may alter stone disintegration products. Three complementary analytical techniques have been used in this study to offer an in‐depth characterization of disintegration products after in vitro Holmium laser lithotripsy: stereoscopic microscopy, scanning electron microscopy and Fourier‐transform infrared spectroscopy. Dust was separated from fragments based on its floating ability in saline irrigation. Depending on initial crystalline constituents, stone dust either conserved attributes found in larger RFs or showed changes in crystalline organization. These included conversion of calcium oxalate dihydrate towards calcium oxalate monohydrate, changes in carbapatite spectra towards an amorphous phase, changes of magnesium ammonium phosphate towards a differing amorphous and crystalline phase and the appearance of hydroxyapatite on brushite fragments. Comparatively, “Moses technology” produced more pronounced changes. These findings provide new insights suggesting a photothermal effect occurring in Holmium laser lithotripsy. Figure: Appearance of hydroxyapatite hexagons on stone dust collected after Holmium laser lithotripsy of a brushite stone using “Moses technology.”   相似文献   

20.
Cell culture process development requires the screening of large numbers of cell lines and process conditions. The development of miniature bioreactor systems has increased the throughput of such studies; however, there are limitations with their use. One important constraint is the limited number of offline samples that can be taken compared to those taken for monitoring cultures in large‐scale bioreactors. The small volume of miniature bioreactor cultures (15 mL) is incompatible with the large sample volume (600 µL) required for bioanalysers routinely used. Spectroscopy technologies may be used to resolve this limitation. The purpose of this study was to compare the use of NIR, Raman, and 2D‐fluorescence to measure multiple analytes simultaneously in volumes suitable for daily monitoring of a miniature bioreactor system. A novel design‐of‐experiment approach is described that utilizes previously analyzed cell culture supernatant to assess metabolite concentrations under various conditions while providing optimal coverage of the desired design space. Multivariate data analysis techniques were used to develop predictive models. Model performance was compared to determine which technology is more suitable for this application. 2D‐fluorescence could more accurately measure ammonium concentration (RMSECV 0.031 g L?1) than Raman and NIR. Raman spectroscopy, however, was more robust at measuring lactate and glucose concentrations (RMSECV 1.11 and 0.92 g L?1, respectively) than the other two techniques. The findings suggest that Raman spectroscopy is more suited for this application than NIR and 2D‐fluorescence. The implementation of Raman spectroscopy increases at‐line measuring capabilities, enabling daily monitoring of key cell culture components within miniature bioreactor cultures. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:337–346, 2017  相似文献   