首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Axial speed of sound (SOS) measurements have been successfully applied to noninvasively evaluate tendon load, while preliminary studies showed that this technique also has a potential clinical interest in the follow up of tendon injuries. The ultrasound propagation theory predicts that the SOS is determined by the effective stiffness, mass density and Poisson's ratio of the propagating medium. Tendon stiffness characterizes the tissue's mechanical quality, but it is often measured in quasi-static condition and for entire tendon segments, so it might not be the same as the effective stiffness which determines the SOS. The objectives of the present study were to investigate the relationship between axial SOS and tendon's nonlinear elasticity, measured in standard laboratory conditions, and to evaluate if tendon's mass density and cross-sectional area (CSA) affect the SOS level. Axial SOS was measured during in vitro cycling of 9 equine superficial digital tendons. Each tendon's stiffness was characterized with a tangent modulus (the continuous derivative of the true stress/true strain curve) and an elastic modulus (the slope of this curve's linear region). Tendon's SOS was found to linearly vary with the square root of the tangent modulus during loading; tendon's SOS level was found correlated to the elastic modulus's square root and inversely correlated to the tendon's CSA, but it was not affected by tendon's mass density. These results confirm that tendon's tangent and elastic moduli, measured in laboratory conditions, are related to axial SOS and they represent one of its primary determinants.  相似文献   

2.
Measure of the cross-sectional area (CSA) of biological specimens is a primary concern for many biomechanical tests. Different procedures are presented in literature but besides the fact that noncontact techniques are required during mechanical testing, most of these procedures lack accuracy or speed. Moreover, they often require a precise positioning of the specimen, which is not always feasible, and do not enable the measure of the same section during tension. The objective of this study was to design a noncontact, fast, and accurate device capable of acquiring CSA of specimens mounted on a testing machine. A system based on the horizontal linear displacement of two charge-coupled device reflectance laser devices next to the specimen, one for each side, was chosen. The whole measuring block is mounted on a vertical linear guide to allow following the measured zone during sample tension (or compression). The device was validated by measuring the CSA of metallic rods machined with geometrical shapes (circular, hexagonal, semicircular, and triangular) as well as an equine superficial digital flexor tendon (SDFT) in static condition. We also performed measurements during mechanical testing of three SDFTs, obtaining the CSA variations until tendon rupture. The system was revealed to be very fast with acquisition times in the order of 0.1 s and interacquisition time of about 1.5 s. Measurements of the geometrical shapes yielded mean errors lower than 1.4% (n=20 for each shape) while the tendon CSA at rest was 90.29 ± 1.69 mm(2) (n=20). As for the tendons that underwent tension, a mean of 60 measures were performed for each test, which lasted about 2 min until rupture (at 20 mm/min), finding CSA variations linear with stress (R(2)>0.85). The proposed device was revealed to be accurate and repeatable. It is easy to assemble and operate and capable of moving to follow a defined zone on the specimen during testing. The system does not need precise centering of the sample and can perform noncontact measures during mechanical testing; therefore, it can be used to measure variations of the specimen CSA during a tension (or compression) test in order to determine, for instance, the true stress and transverse deformations.  相似文献   

3.
Equine superficial digital flexor tendons (SDFT) are often injured, and they represent an excellent model for human sport tendinopathies. While lesions can be precisely diagnosed by clinical evaluation and ultrasonography, a prognosis is often difficult to establish; the knowledge of the injured tendon's mechanical properties would help in anticipating the outcome. The objectives of the present study were to compare the axial speed of sound (SOS) measured in vivo in normal and injured tendons and to investigate their relationship with the tendons' mechanical parameters, in order to assess the potential of quantitative axial ultrasound to monitor the healing of the injured tendons. SOS was measured in vivo in the right fore SDFTs of 12 horses during walk, before and 3.5 months after the surgical induction of a bilateral core lesion. The 12 horses were then euthanized, their SDFTs isolated and tested in tension to measure their elastic modulus and maximal load (and corresponding stress). SOS significantly decreased from 2179.4 ± 31.4 m/s in normal tendons to 2065.8 ± 67.1 m/s 3.5 months after the surgical induction, and the tendons' elastic modulus (0.90 ± 0.17 GPa) was found lower than what has been reported in normal tendons. While SOS was not correlated to tendon maximal load and corresponding stress, the SOS normalized on its value in normal tendons was correlated to the tendons' elastic modulus. These preliminary results confirm the potential of axial SOS in helping the functional assessment of injured tendon.  相似文献   

4.
Matrix metabolism rate differs in functionally distinct tendons.   总被引:1,自引:1,他引:0  
Tendon matrix integrity is vital to ensure adequate mechanical properties for efficient function. Although historically tendon was considered to be relatively inert, recent studies have shown that tendon matrix turnover is active. During normal physiological activities some tendons are subjected to stress and strains much closer to their failure properties than others. Tendons with low safety margins are those which function as energy stores such as the equine superficial digital flexor tendon (SDFT) and human Achilles tendon (AT). We postulate therefore that energy storing tendons suffer a higher degree of micro-damage and thus have a higher rate of matrix turnover than positional tendons. The hypothesis was tested using tissue from the equine SDFT and common digital extensor tendon (CDET). Matrix turnover was assessed indirectly by a combination of measurements for matrix age, markers of degradation, potential for degradation and protein expression. Results show that despite higher cellularity, the SDFT has lower relative levels of mRNA for collagen types I and III. Non-collagenous proteins, although expressed at different levels per cell, do not appear to differ between tendon types. Relative levels of mRNA for MMP1, MMP13 and both pro-MMP3 and MMP13 protein activity were significantly higher in the CDET. Correspondingly levels of cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were higher in the CDET and tissue fluorescence lower suggesting more rapid turnover of the collagenous component. Reduced or inhibited collagen turnover in the SDFT may account for the high level of degeneration and subsequent injury compared to the CDET.  相似文献   

5.
The time-dependent lateral expansion and load relaxation of cartilage cylinders subjected to unconfined compression were simultaneously recorded. These measurements were used to (1) test the assumption of incompressibility for articular cartilage, (2) measure the Poisson's ratio of articular cartilage in compression and (3) investigate the relationship between stress relaxation and volumetric change. Mechanical tests were performed on fetal, calf, and adult humeral head articular cartilage. The instantaneous Poisson's ratio of adult cartilage was 0.49+/-0.08 (mean+S.D.), thus confirming the assumption of incompressibility for this tissue. The instantaneous Poisson's ratio was significantly lower for calf (0. 38+/-0.04) and fetal cartilage (0.36+/-0.04). The equilibrium Poisson's ratio, i.e. true Poisson's ratio of the solid matrix, was significantly higher for the adult tissue (0.26+/-0.11) compared to both the fetal (0.09+/-0.02) and calf (0.11+/-0.03) cartilage. A linear relationship between time-matched load and lateral expansion after the first minute of stress relaxation was observed.  相似文献   

6.
Energy-storing tendons including the equine superficial digital flexor tendon (SDFT) contribute to energetic efficiency of locomotion at high-speed gaits, but consequently operate close to their physiological strain limits. Significant evidence of exercise-induced microdamage has been found in the SDFT which appears not to exhibit functional adaptation; the degenerative changes have not been repaired by the tendon fibroblasts (tenocytes), and are proposed to accumulate and predispose the tendon to rupture during normal athletic activity. The anatomically opposing common digital extensor tendon (CDET) functions only to position the digit, experiencing significantly lower levels of strain and is rarely damaged by exercise. A number of studies have indicated that tenocytes in the adult SDFT are less active in collagen synthesis and turnover than those in the immature SDFT or the CDET. Gap junction intercellular communication (GJIC) is known to be necessary for strain-induced collagen synthesis by tenocytes. We postulate therefore that expression of GJ proteins connexin 43 and 32 (Cx43; Cx32), GJIC and associated collagen expression levels are high in the SDFT and CDET of immature horses, when the SDFT in particular grows significantly in cross-sectional area, but reduce significantly during maturation in the energy-storing tendon only. The hypothesis was tested using tissue from the SDFT and CDET of foetuses, foals, and young adult Thoroughbred horses. Cellularity and the total area of both Cx43 and Cx32 plaques/mm2 of tissue reduced significantly with maturation in each tendon. However, the total Cx43 plaque area per tenocyte significantly increased in the adult CDET. Evidence of recent collagen synthesis in the form of levels of neutral salt-soluble collagen, and collagen type I mRNA was significantly less in the adult compared with the immature SDFT; procollagen type I amino-propeptide (PINP) and procollagen type III amino-propeptide (PIIINP) levels per mm2 of tissue and PINP expression per tenocyte also decreased with maturation in the SDFT. In the CDET PINP and PIIINP expression per tenocyte increased in the adult, and exceeded those in the adult SDFT. The level of PINP per mm2 was greater in the adult CDET than in the SDFT despite the higher cellularity of the latter tendon. In the adult SDFT, levels of PIIINP were greater than those of PINP, suggesting relatively greater synthesis of a weaker form of collagen previously associated with microdamage. Tenocytes in monolayers showed differences in Cx43 and Cx32 expression compared with those in tissue, however there were age- and tendon-specific phenotypic differences, with a longer time for 50% recovery of fluorescence after photobleaching in adult SDFT cells compared with those from the CDET and immature SDFT. As cellularity reduces following growth in the SDFT, a failure of the remaining tenocytes to show a compensatory increase in GJ expression and collagen synthesis may explain why cell populations are not able to respond to exercise and to repair microdamage in some adult athletes. Enhancing GJIC in mature energy-storing tendons could provide a strategy to increase the cellular synthetic and reparative capacity.  相似文献   

7.
This study explores the hypothesis that high-intensity exercise induces degenerative changes in the injury-prone equine superficial digital flexor tendon (SDFT), but not in the rarely injured common digital extensor tendon (CDET). The horse represents a large-animal model that is applicable to human tendon and ligament physiology and pathology. Twelve age-matched female horses undertook galloping exercise three times a week with trotting exercise on alternative days (high-intensity group, n = 6) or only walking exercise (low-intensity group, n = 6) for 18 mo. The SDFT, suspensory ligament, deep digital flexor tendon, and CDET were harvested from the forelimb. Tissue from the mid-metacarpal region of the right limb tendons was analyzed for water, DNA, sulfated glycosaminoglycan and collagen content, collagen type III-to-I ratios, collagen cross-links, and tissue fluorescence. Left limb tendons were mechanically tested to failure. The analyses showed matrix composition to have considerable diversity between the functionally different structures. In addition, the specific structures responded differently to the imposed exercise. High-intensity training resulted in a significant decrease in the GAG content in the SDFT, but no change in collagen content, despite a decrease in collagen fibril diameters. There were no signs of degeneration or change in mechanical properties of the SDFT. The CDET had a lower water content following high-intensity training and a higher elastic modulus. Long-term, high-intensity training in skeletally mature individuals results in changes that suggest accelerated aging in the injury-prone SDFT and adaptation in the CDET.  相似文献   

8.
Stress wave velocities in bovine patellar tendon.   总被引:1,自引:0,他引:1  
The velocity of longitudinal stress waves in an elastic body is given by the square root of the ratio of its elastic modulus to its density. In tendinous and ligamentous tissue, the elastic modulus increases with strain and with strain rate. Therefore, it was postulated that stress wave velocity would also increase with increasing strain and strain rate. The purpose of this study was to determine the velocity of stress waves in tendinous tissue as a function of strain and to compare these values to those predicted using the elastic modulus derived from quasi-static testing. Five bovine patellar tendons were harvested and potted as bone-tendon-bone specimens. Quasi-static mechanical properties were determined in tension at a deformation rate of 100 mm/s. Impact loading was employed to determine wave velocity at various strain levels, achieved by preloading the tendon. Following impact, there was a measurable delay in force transmission across the specimen and this delay decreased with increasing tendon strain. The wave velocities at tendon strains of 0.0075, 0.015, and 0.0225 were determined to be 260 +/- 52 m/s, 360 +/- 71 m/s, and 461 +/- 94 m/s, respectively. These velocities were significantly (p < 0.01) faster than those predicted using elastic moduli derived from the quasi-static tests by 52, 45, and 41 percent, respectively. This study has documented that stress wave velocity in patellar tendon increases with increasing strain and is underestimated with a modulus estimated from quasi-static testing.  相似文献   

9.
Young's modulus and Poisson's ratios of 6mm-sized cubes of equine cortical bone were measured in compression using a micro-mechanical loading device. Surface displacements were determined by electronic speckle pattern-correlation interferometry. This method allows for non-destructive testing of very small samples in water. Analyses of standard materials showed that the method is accurate and precise for determining both Young's modulus and Poisson's ratio. Material properties were determined concurrently in three orthogonal anatomic directions (axial, radial and transverse). Young's modulus values were found to be anisotropic and consistent with values of equine cortical bone reported in the literature. Poisson's ratios were also found to be anisotropic, but lower than those previously reported. Poisson's ratios for the radial-transverse and transverse-radial directions were 0.15+/-0.02, for the axial-transverse and axial-radial directions 0.19+/-0.04, and for the transverse-axial and radial-axial direction 0.09+/-0.02 (mean+/-SD). Cubes located only millimetres apart had significantly different elastic properties, showing that significant spatial variation occurs in equine cortical bone.  相似文献   

10.
Unconfined compression test has been frequently used to study the mechanical behaviors of articular cartilage, both theoretically and experimentally. It has also been used in explant and gel-cell-complex studies in tissue engineering. In biphasic and poroelastic theories, the effect of charges fixed on the proteoglycan macromolecules in articular cartilage is embodied in the apparent compressive Young's modulus and the apparent Poisson's ratio of the tissue, and the fluid pressure is considered to be the portion above the osmotic pressure. In order to understand how proteoglycan fixed charges might affect the mechanical behaviors of articular cartilage, and in order to predict the osmotic pressure and electric fields inside the tissue in this experimental configuration, it is necessary to use a model that explicitly takes into account the charged nature of the tissue and the flow of ions within its porous interstices. In this paper, we used a finite element model based on the triphasic theory to study how fixed charges in the porous-permeable soft tissue can modulate its mechanical and electrochemical responses under a step displacement in unconfined compression. The results from finite element calculations showed that: 1) A charged tissue always supports a larger load than an uncharged tissue of the same intrinsic elastic moduli. 2) The apparent Young's modulus (the ratio of the equilibrium axial stress to the axial strain) is always greater than the intrinsic Young's modulus of an uncharged tissue. 3) The apparent Poisson's ratio (the negative ratio of the lateral strain to the axial strain) is always larger than the intrinsic Poisson's ratio of an uncharged tissue. 4) Load support derives from three sources: intrinsic matrix stiffness, hydraulic pressure and osmotic pressure. Under the unconfined compression, the Donnan osmotic pressure can constitute between 13%-22% of the total load support at equilibrium. 5) During the stress-relaxation process following the initial instant of loading, the diffusion potential (due to the gradient of the fixed charge density and the associated gradient of ion concentrations) and the streaming potential (due to fluid convection) compete against each other. Within the physiological range of material parameters, the polarity of the electric potential depends on both the mechanical properties and the fixed charge density (FCD) of the tissue. For softer tissues, the diffusion effects dominate the electromechanical response, while for stiffer tissues, the streaming potential dominates this response. 6) Fixed charges do not affect the instantaneous strain field relative to the initial equilibrium state. However, there is a sudden increase in the fluid pressure above the initial equilibrium osmotic pressure. These new findings are relevant and necessary for the understanding of cartilage mechanics, cartilage biosynthesis, electromechanical signal transduction by chondrocytes, and tissue engineering.  相似文献   

11.
The objective of this study was to test the hypothesis that tendon echogenicity is associated with the material properties of the corresponding tendon site, especially in case of lesions, due to local changes in tendon matrix composition. Four normal and nine spontaneously injured equine superficial digital flexor tendons (SDFT) were isolated then ultrasonographically examined under tension, in a special device placed in a water bath. Ultrasonographic transversal images (7.5MHz linear transducer) of five segments along each tendon were digitized, and analyzed in order to measure the mean cross-sectional area (MCSA) and mean echogenicity (ME) of each segment. The tendons were then tested in traction until rupture in a testing machine. For each segment, stress and strain were determined throughout the test, and the elastic modulus (EM) was evaluated. The tendon lesions were also documented by histology. No correlation was found between ME and the material properties of normal tendon segments. At the rupture sites of the nine diseased tendons, ME was positively correlated with maximal stress and EM, whereas no correlation was demonstrated with maximal strain. Besides, a positive correlation was demonstrated between ME and both MCSA and EM, when the three metacarpal segments of the diseased tendons were considered. Although ME gives only rough information about tendon matrix structure, it does show, under these in vitro conditions, significant correlations with material properties of pathological tendon segments, which may improve the functional significance and therefore the prognostic value of the ultrasonographic examination of tendon lesions.  相似文献   

12.
Energy storing tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), are highly prone to injury, the incidence of which increases with aging. The cellular and molecular mechanisms that result in increased injury in aged tendons are not well established but are thought to result in altered matrix turnover. However, little attempt has been made to fully characterize the tendon proteome nor determine how the abundance of specific tendon proteins changes with aging and/or injury. The aim of this study was, therefore, to assess the protein profile of normal SDFTs from young and old horses using label-free relative quantification to identify differentially abundant proteins and peptide fragments between age groups. The protein profile of injured SDFTs from young and old horses was also assessed. The results demonstrate distinct proteomic profiles in young and old tendon, with alterations in the levels of proteins involved in matrix organization and regulation of cell tension. Furthermore, we identified several new peptide fragments (neopeptides) present in aged tendons, suggesting that there are age-specific cleavage patterns within the SDFT. Proteomic profile also differed between young and old injured tendon, with a greater number of neopeptides identified in young injured tendon. This study has increased the knowledge of molecular events associated with tendon aging and injury, suggesting that maintenance and repair of tendon tissue may be reduced in aged individuals and may help to explain why the risk of injury increases with aging.  相似文献   

13.
The aim of this study was to determine the characteristic differences in tendinocytes derived from tendons in the equine forelimb, superficial digital flexor tendon (SDFT), deep digital flexor tendon (DDFT) and common digital extensor tendon (CDET), in morphology, proliferation, collagen production ability and ability for synthesis of matrix metalloproteinases (MMPs). Significant differences were observed in cell number in vivo. The cellular number was largest in the SDFT and smallest in the CDET. The values of in vitro proliferation ratios and ability for synthesis of collagen and MMPs were largest in the SDFT and smallest in the CDET. Addition of TNFα to culture of all three types of tendinocytes increased the synthesis of both proMMP-9 (except CDET) and collagen and decreased proMMP-13 synthesis and had no effect on proMMP-2 synthesis. Flexor tendons in forelimbs (SDFT and DDFT) restore energy during locomotion and are more easily injured than are extensor tendons. This structural property would cause active ECM and MMPs synthesis. And CDET have very low turnover potential; in the small number of cells, low cellular proliferation, lower ability for synthesis of collagen and MMPs. The isolated tendinocytes provided much information on the characteristics and properties of tendons for the ECM turnover system and responsiveness of tendinocytes to complex inflammatory responses in tendinopathy.  相似文献   

14.
It has recently been shown that shear wave speed in tendons is directly dependent on axial stress. Hence, wave speed could be used to infer tendon load provided that the wave speed-stress relationship can be calibrated and remains robust across loading conditions. The purpose of this study was to investigate the effects of loading rate and fluid immersion on the wave speed-stress relationship in ex vivo tendons, and to assess potential calibration techniques. Tendon wave speed and axial stress were measured in 20 porcine digital flexor tendons during cyclic (0.5, 1.0 and 2.0 Hz) or static axial loading. Squared wave speed was highly correlated to stress (r2avg = 0.98) and was insensitive to loading rate (p = 0.57). The constant of proportionality is the effective density, which reflects the density of the tendon tissue and additional effective mass added by the adjacent fluid. Effective densities of tendons vibrating in a saline bath averaged 1680 kg/m3 and added mass effects caused wave speeds to be 22% lower on average in a saline bath than in air. The root-mean-square error between predicted and measured stress was 0.67 MPa (6.7% of maximum stress) when using tendon-specific calibration parameters. These errors increased to 1.31 MPa (13.1% of maximum stress) when calibrating based on group-compiled data from ten tendons. These results support the feasibility of calculating absolute tendon stresses from wave speed squared based on linear calibration relationships.  相似文献   

15.
The mechanical behavior of human femurs has been described in the literature with regard to torsion and tension but only as independent measurements. However, in this study, human femurs were subjected to torsion to determine if a simultaneous axial tensile load was generated. Fresh frozen human femurs (n=25) were harvested and stripped of soft tissue. Each femur was mounted rigidly in a specially designed test jig and remained at a fixed axial length during all experiments. Femurs were subjected to external and internal rotation applied at a constant angulation rate of 0.1 deg/s to a maximum torque of 12?N?m. Applied torque and generated axial tension were monitored simultaneously. Outcome measurements were extracted from torsion-versus-tension graphs. There was a strong relationship between applied torsion and the resulting tension for external rotation tests (torsion/tension ratio=551.7±283.8?mm, R(2)=0.83±0.20, n=25), internal rotation tests (torsion/tension ratio=495.3±233.1?mm, R(2)=0.87±0.17, n=24), left femurs (torsion/tension ratio=542.2±262.4?mm, R(2)=0.88±0.13, n=24), and right femurs (torsion/tension ratio=506.7±260.0?mm, R(2)=0.82±0.22, n=25). No statistically significant differences were found for external versus internal rotation groups or for left versus right femurs when comparing torsion/tension ratios (p=0.85) or R(2) values (p=0.54). A strongly coupled linear relationship between torsion and tension for human femurs was exhibited. This suggests an interplay between these two factors during activities of daily living and injury processes.  相似文献   

16.
Tendon tension in vivo may be determined indirectly by measuring intratendinous pressure, by using a buckle transducer or by measuring the tendon strain. All of these methods require appropriate calibration, which is highly dependent on various variables. To measure the tendon load in vivo during a period of 2 weeks in sheep, a measurement technique has been developed using a force sensor interposed serially between the humeral head and the tendon end. Within a supporting frame, a flexion-sensitive force transducer is subjected to three-point bending stress. The load is transmitted by sutures from the tendon end through a hole in the sensor frame, orthogonal to the force transducer. In this configuration, the sensor measures the tensile force acting on the tendon, largely independent of the loading direction. The sensor was screwed to the humeral head and connected to the tendon end which was previously released from its insertion site along with a bone chip, using sutures. Connecting wires passed subcutaneously to a skin outlet about 30 cm away from the transducer. The sensor output was linear to the measured load up to 300 N, with maximum hysteresis of 18% full scale. All sensors worked in vivo without drift over a period of up to 14 days with no change in the calibration data. Forces up to 310 N have been recorded in vivo with daily tension measurements. This study shows that serial tendon tension measurement is feasible and allows for reliable, repeatable recording of the absolute tendon tension at the expense of tendon integrity.  相似文献   

17.
Tendons are exposed to complex loading scenarios that can only be quantified by mathematical models, requiring a full knowledge of tendon mechanical properties. This study measured the anisotropic, nonlinear, elastic material properties of tendon. Previous studies have primarily used constant strain-rate tensile tests to determine elastic modulus in the fiber direction. Data for Poisson's ratio aligned with the fiber direction and all material properties transverse to the fiber direction are sparse. Additionally, it is not known whether quasi-static constant strain-rate tests represent equilibrium elastic tissue behavior. Incremental stress-relaxation and constant strain-rate tensile tests were performed on sheep flexor tendon samples aligned with the tendon fiber direction or transverse to the fiber direction to determine the anisotropic properties of toe-region modulus (E0), linear-region modulus (E), and Poisson's ratio (v). Among the modulus values calculated, only fiber-aligned linear-region modulus (E1) was found to be strain-rate dependent. The E1 calculated from the constant strain-rate tests were significantly greater than the value calculated from incremental stress-relaxation testing. Fiber-aligned toe-region modulus (E(1)0 = 10.5 +/- 4.7 MPa) and linear-region modulus (E1 = 34.0 +/- 15.5 MPa) were consistently 2 orders of magnitude greater than transverse moduli (E(2)0 = 0.055 +/- 0.044 MPa, E2 = 0.157 +/- 0.154 MPa). Poisson's ratio values were not found to be rate-dependent in either the fiber-aligned (v12 = 2.98 +/- 2.59, n = 24) or transverse (v21 = 0.488 +/- 0.653, n = 22) directions, and average Poisson's ratio values in the fiber-aligned direction were six times greater than in the transverse direction. The lack of strain-rate dependence of transverse properties demonstrates that slow constant strain-rate tests represent elastic properties in the transverse direction. However, the strain-rate dependence demonstrated by the fiber-aligned linear-region modulus suggests that incremental stress-relaxation tests are necessary to determine the equilibrium elastic properties of tendon, and may be more appropriate for determining the properties to be used in elastic mathematical models.  相似文献   

18.
As equine musculoskeletal models become common, it is important to determine their sensitivity to the simplifications used. A subject-specific distal forelimb model was created using bones extracted from CT scans to examine movement from in-vivo invasive-marker motion capture. The movements of the sesamoid bones were simulated using the constraints of maintaining an isometric virtual ligament and maintaining contact between the appropriate articular surfaces, creating a variable moment arm for the tendons. The simulation of the proximal sesamoid bones was compared to movement recorded in-vitro. The paths and origins used for the deep digital flexor tendon (DDFT), superficial digital flexor tendon (SDFT) and suspensory ligament (SL) were altered and the effects on their calculated strains during trot stance were examined. The most influential alteration tested was the dorsopalmar changes to the tendon paths at the level of the proximal sesamoid bones, which led to a maximum length reduction of 4 and 2 mm for the SDFT and DDFT, respectively. Alterations to the virtual origins of the SDFT and DDFT were not influential leading to up to a 0.01% effect on strains for a 1cm dorsopalmar shift. In the SL, the choice of the proximal or distal edge of the proximal attachment site varied the strains calculated by up to 1% (3 mm). These results show that within the anatomically realistic spectrum, changes to tendon paths can have an appreciable effect on calculated strains; however the origin sites chosen are not as influential as changes to paths at the metacarpo-phalangeal joint.  相似文献   

19.
Tendons with different in vivo functions are known to have different baseline biomechanics, biochemistry and ultrastructure, and these can be affected by changes in loading. However it is not know whether different tendon types respond in the same, or different ways, to changes in loading.This study performed in vitro un-loading (stress deprivation) in culture on ovine medial extensor tendons (MET, a positional tendon), and superficial and deep digital flexor tendons (SDFTs and DDFTs, with energy-storing and intermediate functions respectively), for 21 days (n = 14 each). Tensile strength and elastic modulus were then measured, followed by biochemical assays for sulphated glycosaminoglycan (sGAG) and hydroxyproline content. Histological inspection for cell morphology, cell density and collagen alignment was also performed.The positional tendon (MET) had a significant reduction (∼50%) in modulus and strength (P < 0.001) after in vitro stress-deprivation, however there were no significant effects on the energy-storing tendons (SDFT and DDFT). In contrast, sGAG was not affected in the MET, but was reduced in the SDFT and DDFT (P < 0.001). All tendons lost compactness and collagen organisation, and had reduced cell density, but these were more rapid in the MET than the SDFT and DDFT.These results suggest that different tendon types respond to identical stimuli in different ways, thus; (i) the results from an experiment in one tendon type may not be as applicable to other tendon types as previously thought, (ii) positional tendons may be particularly vulnerable to clinical stress-deprivation, and (iii) graft tendon source may affect the biological response to loading in ligament and tendon reconstruction.  相似文献   

20.
In-vivo tendon forces are commonly measured using transducers, which detect tension in the tendon fibers. A poorly understood source of measurement errors is the difference in stress distribution within the tendon between experimental and transducer calibration conditions. The objective of this study was to investigate this source of error, and to determine whether these errors could be minimized by proper selection of transducer size. The study was conducted using the infrapatellar ligament (patellar tendon) of New Zealand White rabbits. Tendon force was measured with two different size implantable force transducers (IFTs), one Wide and one Narrow, and by a strain gaged load cell in series with the tendon. Tests were conducted at five different loading conditions selected to produce five different stress distributions within the tendon. One loading condition corresponded to a typical post-experiment calibration, and the data from that condition were used to develop a calibration equation for the transducer. The errors that resulted from using this calibration were determined by comparing the tendon force measured by the in-series load cell with the force predicted from the IFT output using the calibration equation. Changes in stress distribution produced measurement errors up to 64 N with the Narrow IFT but only 24 N with the Wide IFT. We found the measurement error was dependent on sensor width. Our results support the hypothesis that measurement errors can be caused by differences in tendon stress distribution between calibration and experimental conditions. We further showed that these errors can be minimized by using an IFT, which samples the tension in a large percentage of the tendon fibers. Information from this study can be used for selection of an appropriately sized implantable force transducer for measuring tendon and ligament force.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号