首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
A simplified method for the simultaneous determination of irinotecan (CPT-11, I) and its active metabolite (SN-38, II) in human plasma by high-performance liquid chromatography (HPLC) with fluorescence detection has been developed. Following the addition of the internal standard (I.S.) camptothecin, the drugs were extracted from plasma using methanol. The average extraction efficiencies were 87% for I, 90% for II and 90% for the I.S. Chromatography was performed using a TSK gel ODS-80Ts column, monitored at 556 nm (excitation wavelength, 380 nm) and the mobile phase was acetonitrile-50 mM disodium hydrogen phosphate (28:72) containing 5 mM heptanesulphonate (pH 3.0). The linear quantitation ranges for I and II were 30–2000 and 1–30 ng/ml, respectively.  相似文献   

2.
A reversed-phase high-performance liquid chromatographic (HPLC) using ultraviolet (UV) absorbance detection method for simultaneous determination of clofibrate (I) and its major metabolite clofibric acid (II) in human plasma has been developed to support a clinical study. I, II and internal standard (I.S., III) are isolated from human plasma by 96-well solid-phase extraction (SPE) C(18)z.ccirf;AR plate and quantified by direct injection of the SPE eluent onto the HPLC with UV detection wavelength at 230 nm. Two chromatographic methods, isocratic and step gradient, have been validated from 1.0 to 100.0 microg/ml and successfully applied to plasma sample analysis for a clinical study. The lower limit of quantitation (LLOQ) is 1.0 microg/ml for both I and II when 500 microl plasma sample is processed. Sample collection and preparation is conducted at 5 degrees C to minimize the hydrolysis of I to II in human plasma.  相似文献   

3.
In the present study, a first validated and green spectrofluorimetric approach for its assessment and evaluation in different matrices was investigated. After using an excitation wavelength of 345 nm, Roxadustat (ROX) demonstrates a highly native fluorescence at an emission of 410 nm. The influences of experimental factors such as pH, diluting solvents, and different organized media were tested, and the most appropriate solvent choice was ethanol. It was confirmed that there was a linear relationship between the concentration of ROX and the relative fluorescence intensity in the range 60.0–1000.0 ng ml−1, with the limit of detection and limit of quantitation, respectively, being 17.0 and 53.0 ng ml−1. The mean recoveries % [±standard deviation (SD), n = 5] for pharmaceutical preparations were 100.11% ± 2.24%, whereas for plasma samples, they were 100.08 ± 1.08% (±SD, n = 5). The results obtained after the application of four greenness criteria, Analytical Eco-Scale metric, NEMI, GAPI, and AGREE metric, confirmed its eco-friendliness. In addition, the whiteness meter (RGB12) confirmed its level of sustainability. The International Council for Harmonisation (ICH) criteria were used to verify the developed method through the study in both spiked plasma samples and content uniformity evaluation. An appropriate standard for various applications in industry and quality control laboratories was developed.  相似文献   

4.
A new indirect RP-HPLC method was developed for determination of small, ng/ml, concentrations of triamcinolone (TMC) in human plasma, in presence of endogenous corticosteroids: cortisol (hydrocortisone, F), cortisone (E) and their metabolites, after administration of TMC in a free alcohol form. After solid phase extraction (SPE) in cartridges with octadecyl phase, TMC and prednisolone (I.S.) were derivatized by treatment with 9-anthroyl nitrile (9-AN) in a basic mixture, consisting of triethanolamine and quinuclidine, to receive fluorescent esters at 21-hydroxyl group of the steroid chain. Optimal conditions were also established to purify fluorescent TMC and I.S. derivatives before injection into HPLC column. The fluorescent esters were determined using an isocratic RP-HPLC technique in a C18 column. The mobile phase consisted of acetonitrile and 0.3 mM ortho-phoshoric acid. The method was validated before using to pharmacokinetic studies. Calibration curve of TMC was linear in the range of 2.5-100.0 ng/ml. Intra- and inter-day measurement precision and accuracy were equal to or lower than 15%. Percent recovery, and limits of detection (LOD) and quantification (LOQ) of TMC were also determined. The method was applied for in vivo conditions after administration of tablets containing TMC to healthy volunteers. Moreover, the method provided potential to determine TMC and, simultaneously, other glucocorticoids: E, F and their metabolites in one analytical run. Column interactions were observed between endogenous metabolites of E. Usefulness of the elaborated method was confirmed in pharmacokinetic studies following administration of a small (4 mg) dose of TMC to human volunteers. The method can provide an alternative to HPLC coupled with RIA in determination of small quantities of TMC.  相似文献   

5.
A rapid, sensitive and reproducible reversed-phase HPLC assay was developed for the determination of amprolium (APL) in chicken plasma. Protein in plasma sample was precipitated with 0.33 M perchloric acid and supernatant solution was injected into the HPLC system. Following the chromatographic separation of APL and the beclotiamine (I.S.) on a C18 column, the derivatives of APL and I.S. were formed by post-column reaction and detected by fluorescence detection (excitation at 400 nm, emission at 460 nm). The method showed excellent precision, accuracy and speed with a detection limit of 2 ng/ml. The intra- and inter-assay variance of this method were less than 11.2%. This method has been successfully applied to plasma determinations after oral administration of APL to chicken.  相似文献   

6.
A new straightforward method based on cloud-point extraction (CPE) has been developed, optimized and validated for the determination of venlafaxine in human plasma by reversed-phase high-performance liquid chromatography with fluorescence detection. The non-ionic surfactant Triton X-114 (polyethylene glycol tert-octylphenyl ether) was chosen as the extract solvent. Separation was obtained using a reversed-phase Diamonsil column (C(18), 250mmx4.6mm I.D., 5mum) and a mobile phase composed of acetonitrile-phosphate buffer solution (pH 3.0)-triethylamine (33.5:66.5:0.4). Fluorescence detection was used (lambda(ex) 276nm, lambda(em) 598nm). Maprotiline was used as the internal standard. Under the optimum conditions, the linear range of venlafaxine in human plasma was 10-800ngmL(-1) (r(2)=0.9995). The limit of detection (LOD) was less than 2ngmL(-1) (S/N=3) and the limit of quantification (LOQ) was less than 10ngmL(-1) (S/N=10). The method was successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine capsules in nine healthy volunteers.  相似文献   

7.
An HPLC- fluorescence method to quantitate total 7-ethyl-10-hydroxy-camptothecin (SN-38) in beagle dog plasma spiked with liposome based formulation of SN-38 (LE-SN38) and using camptothecin (CPT) as the internal standard (I.S.) was developed and validated to support pharmacokinetics/toxicokinetics studies. Sample preparation was done by protein precipitation using acetonitrile with 0.5% acetic acid. The supernatant was evaporated, and reconstituted in acetonitrile-20 mM ammonium acetate, pH 3.5 (20:80, v/v). When injected onto a Zorbax SB-C(18) HPLC column SN-38 as well as I.S. were detected by fluorescence using an excitation at 368 nm and emission at 515 nm. The SN-38 concentrations in samples were calculated from a standard curve of peak area ratios of SN-38 to the I.S. using weighted linear regression. The sensitivity limit for SN-38 was 1.00 ng/ml in beagle dog plasma with a precision (expressed as relative standard deviation) of 12.4% and an accuracy (expressed as analytical recovery) of 104%. The assay was linear within the standard curve range of 1-750 ng/ml. Acceptable precision and accuracy were also obtained for concentrations over the balance of the standard curve range from between-run and within-run calculations.  相似文献   

8.
The determination of propanolol enantiomers in microsamples of human plasma and urine by HPLC using a chiral stationary phase is described. After extraction from 200 μl of plasma or urine with racemic alprenolol as internal standard (I.S.), the enantiomers are separated on a β-cyclodextrin column with a polar organic mobile phase and determined by fluorescence detection. The retention times of I.S. and propranolol enantiomers are about 12–13 min and 16–18 min, respectively. Peak resolutions are 1.4 for I.S. and 2.2 for propranol. The use of alprenolol as I.S. improves significantly the coefficients of variation (C.V.: 0.6–4.2%). Sensitivity is approximately 1.5 ng/ml per propranolol enantiomer. The assay is applied to pharmacokinetic studies of racemic propranolol in human biological fluids. The (S)-propranolol levels are always higher than the (R)-antipode concentrations in plasma and urine.  相似文献   

9.
A high-performance liquid chromatographic (HPLC) assay suitable for the analysis of the enantiomers of ketoprofen (KT), a 2-arylpropionic acid (2-APA) non-steroidal antiinflammatory drug (NSAID), in plasma and urine was developed. Following the addition of racemic fenoprofen as internal standard (I.S.), plasma containing the KT enantiomers and I.S. was extracted by liquid-liquid extraction at an acidic pH. After evaporation of the organic layer, the drug and I.S. were reconstituted in mobile phase and injeted into the HPLC system. The enantiomers were separated at ambient temperature on a commercially available 250 × 4.3 mm amylose carbamate-packed chiral column (Chiralpak AD) column with hexane-isopropyl alcohol-trifluoroacetic acid (80:19.9:0.1, v/v/v) as the mobile phase pumped at 1.0 ml/min. The enantiomers of KT were quantified by ultraviolet detection with the wavelength set at 254 nm. The assay described allows for the direct quantification of KT enantiomers without pre-column derivatization, and is suitable for clinical studies of KT enantiomers in human plasma and urine after administration of therapeutic doses.  相似文献   

10.
A simple, accurate and precise high-performance liquid chromatographic method with fluorescence detection was developed and validated for the determination of gemifloxacin (GEM) in rat plasma using furosemide as internal standard (I.S.). Plasma samples were pretreated by direct deproteinization and all samples and standard solutions were chromatographed at 45°C using triethylamine solution (0.5%, v/v, pH 3.0±0.1), methanol and acetonitrile (63:30:7, v/v/v) as the mobile phase. Chromatographic resolution was achieved using a RP-C(18) column (Atlantis, Waters, 150 mm × 4.6 mm, 5 μm) at a flow rate of 1.0 mL min(-1) and an injection volume of 30 μL. The analytes were measured by fluorescence detection with excitation and emission wavelengths of 344 nm and 399 nm, respectively. The retention times for GEM and I.S. were approximately 7.5 and 12.6 min, respectively. The lower limit of quantitation (LLOQ) was 20 ng mL(-1) and the calibration curves were linear over a concentration range of 20-5000 ng mL(-1). The intra- and inter-day precisions, expressed by relative standard deviation (R.S.D.) were lower than 6.24% and 4.49%, respectively. The accuracy ranged from 91.3% to 112% and from 98.8% to 106% for the lower and upper limit of quantitation of the calibration curve, respectively. Ratio of peak area of analyte to I.S. was used for quantification of plasma samples. No interferences from endogenous substances were found. The recovery of GEM and I.S. from plasma was greater than 90%. Drug stability in plasma was shown at room temperature for 4h, after three freeze-thaw cycles for 24h, in freezer at -80°C for 60 days, and in the autosampler after processing for 12h. The utility of the assay was confirmed by the successful analysis of plasma samples from GEM pharmacokinetics studies in the rats after intravenous administration.  相似文献   

11.
多序列比对的量子点荧光探针检测金黄色葡萄球菌的研究   总被引:1,自引:0,他引:1  
利用以量子点(Quantum dot,QD)作为供体、有机荧光染料作为受体的荧光能量共振转移(Fluores—cence resonance energy transfer,FRET)体系检测核酸等大分子是一种非常重要的检测手段。本文构建了一种检测金黄色葡萄球菌种特异性16SrDNA的新方法。此方法以羧基修饰的525nm量子点与氨基修饰的DNA在EDC的作用下通过脱水连接形成QD—DNA复合物作为荧光能量共振转移体系的供体、有机荧光基团ROX修饰的DNA作为荧光能量共振转移体系的受体组成能与金黄色葡萄球菌种特异性16SrDNA杂交的检测探针。当探针与靶序列发生杂交时,作为供体的525nmQD与作为受体的ROX之间的距离被缩短至能有效发生荧光能量共振转移的距离之内。此时,以不能致ROX发光的波长激发量子点发光,其荧光强度下降,而ROX的荧光强度上升。在不存在靶序列的情况下,不会发生这种荧光强度的变化。QD与ROX荧光强度的变化是实现本检测体系快速、简单的重要保证。  相似文献   

12.
A liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the simultaneous determination of a new potent motilin receptor agonist as erythromycin derivative, EM574 (erythromycin derivative), and its three metabolites, M-IV, M-V and M-VI, in human plasma was developed. The internal standards (I.S.s) used were deuterated EM574, M-IV and M-V. For the quantitation of M-VI, deuterated M-V was used. The analytes and I.S. were extracted from plasma samples with diethyl ether at neutral pH. A turbo ion spray interface was used as the ion source of LC–MS–MS, and the analysis was performed in the selected reaction monitoring mode. The lower quantitation limits for all the analytes were 0.05 ng/ml when 0.2 ml of plasma was used, and the standard curves were linear in the range 0.05 to 20 ng/ml. The method was precise; the intra- and inter-day precisions of the method were not more than 19.8% for all the analytes. The accuracy of the method was good with the deviations between added and calculated concentrations of each analyte being typically within ±11.2%.  相似文献   

13.
A selective and sensitive analytical method for the simultaneous measurement of dolasetron (I) and its major metabolite, MDL 74,156 (II), in human plasma and urine samples has been developed using a structural analogue, MDL 101,858, as internal standard (I.S.). The compounds were extracted from plasma and urine using solvent extraction after the addition of the I.S. Chromatographic separation was carried out on a reversed-phase HPLC column and detection and quantification was by fluorescence with excitation and emission wavelengths of 285 and 345 nm, respectively. Linear responses were obtained over concentration ranges of 5 to 1000 pmol/ml for plasma samples and 20 to 1000 pmol/ml for urine samples with correlation coefficients for the calibration curves exceeding 0.999 in all cases. Intra-day and inter-day reproducibility yielded limits of quantification of 10 pmol/ml for I and 5 pmol/ml for II in plasma and 50 pmol/ml for I and II in urine. The method has been applied to the simultaneous analysis of both compounds in plasma and urine samples coming from clinical pharmacokinetic studies.  相似文献   

14.
A heart-cut column-switching, ion-pair, reversed-phase HPLC system was used for the quantitation of efletirizine (EFZ) in biological fluids. The analyte and an internal standard (I.S.) were extracted from human EDTA plasma by C18 solid-phase extraction (SPE) using a RapidTrace® workstation. The eluent from the SPE was evaporated, reconstituted and injected onto the HPLC column. Urine samples were diluted and injected directly without the need of extraction. The compounds of interest were separated from most of the extraneous matrix materials by the first C18 column, and switched onto a second C18 column for further separation using a mobile phase of stronger eluting capability. Linearity range was 10–2000 ng ml−1 for plasma and 0.05–10 μg ml−1 for urine. The lower limit of quantitation (LOQ) was 10 ng from 1 ml of plasma, with a signal-to-noise ratio of 15:1. Inter-day precision and bias of quality control samples (QCs) were <5% for plasma and <7% for urine. Selectivity was established against six other antihistamines, three analogs of efletirizine, and on 12 control plasma lots and nine control urine lots. Recovery was 90.0% for EFZ and 89.5% for I.S. from plasma. One hundred samples can be processed in every 2.75 h on a 10-module RapidTrace® workstation with minimal human attention. Method ruggedness were tested on three brands of SPE and six different lots of one SPE brand. Performance ruggedness was demonstrated by different analysts on multiple HPLC systems. Analyte stability through sample storage, extraction process (benchtop, freeze–thaw, refrigeration after extraction) and chromatography (on-system, reinjection) was established.  相似文献   

15.
A new and specific HPLC–DAD method for the direct determination of Prulifloxacin and its active metabolite, Ulifloxacin, in human plasma has been developed. Plasma samples were analysed after a simple solid phase extraction (SPE) clean-up using a new HILIC stationary phase based high-performance liquid chromatography (HPLC) column and an ammonium acetate buffer (5?mM, pH 5.8)/acetonitrile (both with 1% Et3N, v/v) mobile phase in isocratic elution mode, with Danofloxacin as the internal standard. Detection was performed using DAD from 200 to 500?nm and quantitative analyses were carried out at 278?nm. The LOQ of the method was 1?μg/mL of the cited analytes and the calibration curve showed a good linearity up to 25?μg/mL. For both analytes the precision (RSD%) and the trueness (bias%) of the method fulfil with International Guidelines. The method was applied for stability studies, at three QC concentration levels, in human plasma samples stored at different temperature of?+?25,?+?4 and ?20?°C in order to evaluate plasma stability profiles.  相似文献   

16.
A simple, sensitive and fully automated analytical method for the analysis of codeine in human plasma is presented. Samples are added with oxycodone, used as internal standard (I.S.), and directly loaded in the autosampler tray. An on-line sample clean-up system based on solid-phase extraction (SPE) cartridges (Bond-Elut C2, 20 mg) and valve switching (Prospekt) is used. Isocratic elution improved reproducibility and allowed the recirculation of the mobile phase. A Hypersil BDS C18, 3 μm, 10×0.46 cm column was used and detection was done by UV monitoring at 212 nm. Retention times of norcodeine (codeine metabolite), codeine and oxycodone (I.S.) were 5.5, 6.4 and 9.1 min, respectively. Morphine was left to elute in the chromatographic front. Detection limit for codeine was 0.5 μg l−1 and inter-assay precision (expressed as relative standard deviation) and accuracy (expressed as relative error) measured at 2 μg l−1 were 5.03% and 1.82%. Calibration range was 2–140 μg l−1.  相似文献   

17.
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis (CZE) for the analysis of tobramycin in human serum is presented. An off-line SPE employing a carboxypropyl bonded phase (CBA) cartridge was used for the extraction of tobramycin from human serum. Adsorbed tobramycin was eluted from the CBA cartridge using a mixture of NH(3) (25%, w/v)-methanol (30:70, v/v). After evaporation, the analyte was reconstituted and derivatized with o-phthaldialdehyde (OPA)/3-mercaptopropionic acid (MPA). The resulting tobramycin-OPA/MPA derivative was purified, and then identified by mass spectrometry. The tobramycin-OPA/MPA derivative was then analysed by CZE with a background electrolyte (BGE) comprising of 30 mM sodium tetraborate pH 10.0-acetonitrile (ACN) (80:20, v/v) with ultraviolet detection at 230 nm. A linear response was observed in the range of 0.3-30 microg/ml with r(2) = 0.992. The sensitivity of the method was determined by its limit of quantitation (LOQ) and limit of detection (LOD) of 0.3 microg/ml and 0.1 microg/ml, respectively. SPE recovery ranged from 68 to 79% at the trough levels to 98% at the peak levels found in serum. Furosemide has been added as internal standard (IS) to improve precision. For the therapeutic range of tobramycin in serum (2-10 microg/ml) the relative standard deviation (R.S.D.) was less than 11% for the entire SPE/CE process. The method demonstrated excellent selectivity as shown by the lack of interference from a total of 20 drugs investigated. The method was then used in therapeutic drug monitoring of patients receiving the drug.  相似文献   

18.
A novel, highly sensitive method for the determination of pilocarpic acid (PA) in human plasma is described. In addition, the method provides for the conversion of the lactone, pilocarpine (P), to PA so that a total drug presence can be determined. Using novel high-performance liquid chromatographic conditions capable of separating P, isopilocarpine (I-P), PA and isopilocarpic acid (I-PA) from each other and from endogenous plasma impurities, it was confirmed that P exclusively and quantitatively converts to PA in heparinized human plasma during storage. For the determination of PA, the selective extraction of PA from protein-free plasma was accomplished using two different solid-phase extraction (SPE) cartridges in two consecutive SPE steps. After extraction, PA was lactonized with trifluoroacetic acid back to P, and both P and an internal standard were acylated using heptafluorobutyric anhydride (HFBA). The trifluoroacetylated derivatives were monitored using gas chromatography (GC) with mass spectrometric (MS) detection. This procedure allowed the sensitive and reliable determination of PA with a limit of quantification (LOQ) of 1 ng/ml, which could not be achieved using previously described methods. The assay was validated in the concentration range of 1 to 10 ng/ml with an intra-day precision (expressed as the coefficient of variation, C.V.) ranging from 9.9 to 0.5%. Inter-day precision for the quality control standard at 2.5 ng/ml showed a C.V. of 10.2%. Accuracy ranged from 94 to 102%. The assay was used to monitor the maximum systemic exposure to P, administered by the ocular route, in terms of total plasma PA (P and PA).  相似文献   

19.
An HPLC method was developed for the determination of a new oxazolidinone, DA-7867 (I), in human plasma and urine and in rat tissue homogenates. To 100 microl of biological sample, 300 microl acetonitrile and 50 microl methanol containing 10 microg/ml DA-7858 (the internal standard) were added. After vortex-mixing and centrifugation, the supernatant was evaporated under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of the mobile phase and a 50-microl aliquot was injected directly onto the reversed-phase (C(18)) column. The mobile phase, 20 mM KH2PO4:acetonitrile (75:25, v/v) was run at a flow rate of 1.5 ml/min and the column effluent was monitored by a UV detector set at 300 nm. The retention times of I and DA-7858 were approximately 6.5 and 8.7 min, respectively. The detection limits of I in human plasma and urine and in rat tissue homogenates were 20, 20, and 50 ng/ml, respectively.  相似文献   

20.
A selective and reproducible high-performance capillary electrophoretic (HPCE) method for the quantification of amikacin (AMK), an aminocyclitol antibiotic, in human plasma, has been developed for use in clinical laboratory tests. The method involves ultrafiltration (UF) of plasma before derivatization with the fluorescence derivatization reagent 1-methoxy-carbonylindolizine-3,5-dicarbaldehyde at room temperature for 15 min in the dark. An aliquot of the derivatives is directly introduced into the fused-silica capillary [75 cm (effective length)×50 μm I.D.] at the anode side by dynamic compression injection (50 hPa for 6 s). After electrophoresis with 40 mM SDS-20 mM phosphate-borate buffer (pH 7) in the micellar electrokinetic chromatography (MEKC) mode at 30 kV, the derivative had a retention time of 16.7 min and was detected by fluorescence intensity at 482 nm (with irradiation at 414 nm). The precision (n = 5) of the method is 4.08 and 1.59% (C.V.) at the 50 and 100 μg AMK/ml plasma levels, respectively. Linearity (r = 0.998) was established over the concentration range 5–100 mg of AMK/ml plasma and the detection limit (at a signal-to-noise ratio of 3) is 0.5 μg AMK/ml plasma. This assay method could potentially have wider application in the determination of other aminocyclitol antibiotics, such as arbekacin, dibekacin, kanamycin, in human plasma as well as of AMK.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号