首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
The purpose of this study was to investigate the force-producing characteristics of boys aged 13 years in relation to fatigue of elbow flexor muscles. Maximal voluntary force in elbow flexion was measured before and after a muscle endurance test (MET) by using an isokinetic dynamometer isometrically, concentrically and eccentrically at three velocities, i.e. 0.21, 0.52, and 1.05 rad · s–1. The MET consisted of maximal concentric and eccentric muscle actions performed alternately at 0.52 rad · s–1 for 50 consecutive trials. Muscle cross-sectional area (CSA) of elbow flexor muscles (biceps brachii and brachialis) was measured by a B-mode ultrasound apparatus. Although eccentric force showed significantly higher values than concentric force during MET, there was no significant difference in the rate of decline in force between the two actions. There was no significant difference in the rate of decline in force after MET for each velocity and muscle action. Isometric, concentric and eccentric force before MET was significantly related to muscle CSA whereas, after MET, concentric force significantly correlated with muscle CSA but there was no significant correlation between muscle CSA and isometric or eccentric force. From our study, it is therefore suggested that in development to maturity, isometric, concentric and eccentric force decrease at the same rate with advancing muscle fatigue; however, there might be differences among muscle actions in facors affecting force development.  相似文献   

2.
We examined the temporal changes of isokinetic strength performance of knee flexor (KF) and extensor (KE) strength after a football match. Players were randomly assigned to a control (N = 14, participated only in measurements and practices) or an experimental group (N = 20, participated also in a football match). Participants trained daily during the two days after the match. Match and training overload was monitored with GPS devices. Venous blood was sampled and muscle damage was assessed pre-match, post-match and at 12h, 36h and 60h post-match. Isometric strength as well as eccentric and concentric peak torque of knee flexors and extensors in both limbs (dominant and non-dominant) were measured on an isokinetic dynamometer at baseline and at 12h, 36h and 60h after the match. Functional (KFecc/KEcon) and conventional (KFcon/KEcon) ratios were then calculated. Only eccentric peak torque of knee flexors declined at 60h after the match in the control group. In the experimental group: a) isometric strength of knee extensors and knee flexors declined (P<0.05) at 12h (both limbs) and 36h (dominant limb only), b) eccentric and concentric peak torque of knee extensors and flexors declined (P<0.05) in both limbs for 36h at 60°/s and for 60h at 180°/s with eccentric peak torque of knee flexors demonstrating a greater (P<0.05) reduction than concentric peak torque, c) strength deterioration was greater (P<0.05) at 180°/s and in dominant limb, d) the functional ratio was more sensitive to match-induced fatigue demonstrating a more prolonged decline. Discriminant and regression analysis revealed that strength deterioration and recovery may be related to the amount of eccentric actions performed during the match and athletes'' football-specific conditioning. Our data suggest that recovery kinetics of knee flexor and extensor strength after a football match demonstrate strength, limb and velocity specificity and may depend on match physical overload and players'' physical conditioning level.  相似文献   

3.
4.
Eccentric exercise has been extensively used as a model to study muscle damage-induced neuromuscular impairment, adopting mainly a bilateral matching task between the reference (unexercised) arm and the indicator (exercised) arm. However, little attention has been given to the muscle proprioceptive function when the exercised arm acts as its own reference. This study investigated muscle proprioception and motor control, with the arm acting both as reference and indicator, following eccentric exercise and compared them with those observed after isometric exercise. Fourteen young male volunteers were equally divided into two groups and performed an eccentric or isometric exercise protocol with the elbow flexors of the non-dominant arm on an isokinetic dynamometer. Both exercise protocols induced significant changes in indicators of muscle damage, that is, muscle soreness, range of motion and maximal isometric force post-exercise (p < 0.05–0.001), and neuromuscular function was similarly affected following both protocols. Perception of force was impaired over the 4-day post-exercise period (p < 0.001), with the applied force being systematically overestimated. Perception of joint position was significantly disturbed (i.e., target angle was underestimated) only at one elbow angle on day 4 post-exercise (p < 0.05). The misjudgements and disturbed motor output observed when the exercised arm acted as its own reference concur with the view that they could be a result of a mismatch between the central motor command and an impaired motor control after muscle damage.  相似文献   

5.
The influence of muscle activation and the time allowed for torque generation on the angle-specific torque-velocity relationship of the triceps surae was studied during plantar flexion using supramaximal electrical stimulation and a release technique on six male subjects [mean (SD) age 25 (4) years]. Torque-velocity data were obtained under different levels of constant muscle activation by varying the stimulus frequency and the time allowed for isometric torque generation prior to release and isokinetic shortening. To eliminate the effects of the frequency response on absolute torque the isokinetic data were normalized to the maximum isometric torque values at 0.44 rad. There were no significant differences in the normalized torques generated at any angular velocity using stimulus frequencies of 20, 50 or 80 Hz. When the muscle was stimulated at 50 Hz the torques obtained after a 400 ms and 1 s pre-release isometric contraction did not differ significantly. However, with no pre-release contraction significantly less torque was generated at all angular velocities beyond 1.05 rad · s–1 when compared with either the 200, 400 ms or 1 s condition. With a 200 ms pre-release contraction significantly less torque was generated at angular velocities beyond 1.05 rad · s–1 when compared with the 400 ms or 1 s conditions. It would seem that the major factor governing the shape of the torque-velocity curve at a constant level of muscle activation is the time allowed for torque generation.  相似文献   

6.
《Chronobiology international》2013,30(4-5):645-660
Diurnal variation in muscle performance has been well documented in the past few years, but almost exclusively in the male population. The possible effects of the menstrual cycle on human circadian rhythms have remained equivocal, particularly in the context of muscle strength. The purpose of the study was to analyze the isolated and combined effects of circamensal variation and diurnal changes on muscle strength. Eight eumenorrheic females (age 30 ± 5 yrs, height 1.63 ± 0.06 m and body mass 66.26 ± 4.6 kg: mean ± SD) participated in this investigation. Isokinetic peak torque of knee extensors and flexors of the dominant leg were measured at 1.05, 3.14 rad.s?1 (through 90° ROM) at two times-of-day (06:00, 18:00 h) and five time points of the menstrual cycle (menses, mid-follicular, ovulation, mid-luteal, late luteal). In addition, maximum voluntary isometric contraction of knee extensors and flexors and electrically stimulated isometric contraction of the knee extensors were measured at 60° of knee flexion. Rectal temperature was measured during 30 min before the tests. There was a significant time-of-day effect on peak torque values for isometric contraction of knee extensors under electrical stimulation (P < 0.05). At 18:00 h, muscle force was 2.6% greater than at 06:00 h. The time-of-day effect was not significant when the tests were performed voluntarily without stimulation: effect size calculations indicated small differences between morning and evening for maximal voluntary isometric contraction and peak torque (at 1.05 rad.s?1) for the knee extensors. A circamensal variation was observed for peak torque of knee flexors at 1.05 rad.s?1, extensors at 3.14 rad.s?1, and also isometric contraction of knee flexors, values being greatest at the ovulation phase. Interaction effects between time-of-day and menstrual cycle phase were not observed in any of the indices of muscle strength studied. The phase of the menstrual cycle seemed to have a greater effect than did the time-of-day on female muscle strength in this group of subjects. The present results suggest that peripheral rather than central mechanisms (e.g., motivation) are implicated in the diurnal variation of maximal isometric strength of women.  相似文献   

7.
This study assessed muscle fatigue patterns of the elbow flexors in untrained men and women to determine if sex differences exist during acute maximal eccentric exercise. High-intensity eccentric exercise is often used by athletes to elicit gains in muscle strength and size gains. Development of fatigue during this type of exercise can increase risk of injury; therefore, it is important to understand fatigue patterns during eccentric exercise to minimize injury risk exposure while still promoting training effects. While many isometric exercise studies have demonstrated that women show less fatigue, the patterns of fatigue during purely eccentric exercise have not been assessed in men and women. Based on the lack of sex differences in overall strength loss immediately post-eccentric exercise, it was hypothesized that women and men would have similar relative fatigue pattern responses (i.e., change from baseline) during a single bout of maximal eccentric exercise. Forty-six subjects (24 women and 22 men) completed 5 sets of 10 maximal eccentric contractions on an isokinetic dynamometer. Maximal voluntary isometric contraction strength was assessed at baseline and immediately following each exercise set. Maximal eccentric torque and contractile properties (i.e., contraction time, work, half relaxation time, and maximal rate of torque development) were calculated for each contraction. Men and women demonstrated similar relative isometric (32% for men and 39% for women) and eccentric (32% for men and 39% for women) fatigue as well as similar deficits in work done and rates of torque development and relaxation during exercise (p > 0.05). Untrained men and women displayed similar relative responses in all measures of muscle function during a single bout of maximal eccentric exercise of the elbow flexors. Thus, there is no reason to suspect that women may be more vulnerable to fatigue-related injury.  相似文献   

8.
The purpose of this investigation was to determine the mechanomyographic (MMG) amplitude and mean power frequency (MPF) versus torque (or force) relationships during isokinetic and isometric muscle actions of the biceps brachii. Ten adults (mean +/- SD age = 21.6 +/- 1.7 years) performed submaximal to maximal isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects randomly performed submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Polynomial regression analyses indicated that MMG amplitude increased linearly with torque during both the isokinetic (r2 = 0.982) and isometric (r2 = 0.956) muscle actions. From 80% to 100% of isometric MVC, however, MMG amplitude appeared to plateau. Cubic models provided the best fit for the MMG MPF versus isokinetic (R2 = 0.786) and isometric (R2 = 0.940) torque relationships, although no significant increase in MMG MPF was found from 10% to 100% of isokinetic PT. For the isometric muscle actions, however, MMG MPF remained relatively stable from 10% to 50% MVC, increased from 50% to 80% MVC, and decreased from 80% to 100% MVC. The results demonstrated differences in the MMG amplitude and MPF versus torque relationships between the isokinetic and isometric muscle actions. These findings suggested that the time and frequency domains of the MMG signal may be useful for describing the unique motor control strategies that modulate dynamic versus isometric torque production.  相似文献   

9.
We assessed and compared sensitivities of dynamic simulations to musculotendon (MT) parameters for gait and dynamometer experiments. Our aim with this comparison was to investigate whether dynamometer experiments could provide information about MT-parameters that are important to reliably study MT-function during gait. This would mean that dynamometer experiments could be used to estimate these parameters. Muscle contribution to the joint torque (MT-torque) rather than relative MT-force primarily affects the resulting gait pattern and torque measured by the dynamometer. In contrast to recent studies, therefore, we assessed the sensitivity of the MT-torque, rather than the sensitivity of the relative MT-force. Based on sensitivity of the MT-torque to a parameter perturbation, MT-parameters of the knee flexors and extensors were classified in three categories: low, medium, and high. For gait, classification was based on the average sensitivity during a gait cycle. For isometric and isokinetic dynamometer experiments, classification was based on the highest sensitivity found in the experiments. The calculated muscle contributions to the knee torque during gait and dynamometer experiments had a high sensitivity to only a limited number of MT-parameters of the knee flexors and extensors, suggesting that not all MT-parameters need to be estimated. In general, the highest sensitivity was found for tendon slack length. However, for some muscles the sensitivity to the optimal fibre length or the maximal isometric muscle force was also high or medium. The classification of the individual MT-parameters for gait and dynamometer experiments was largely similar. We therefore conclude that dynamometer experiments provide information about MT-parameters important to reliably study MT-function during gait, so that subject-specific estimates of MT-parameters could be made based on dynamometer experiments.  相似文献   

10.
This study compared resistance-trained and untrained men for changes in commonly used indirect markers of muscle damage after maximal voluntary eccentric exercise of the elbow flexors. Fifteen trained men (28.2 +/- 1.9 years, 175.0 +/- 1.6 cm, and 77.6 +/- 1.9 kg) who had resistance trained for at least 3 sessions per week incorporating exercises involving the elbow flexor musculature for an average of 7.7 +/- 1.4 years, and 15 untrained men (30.0 +/- 1.5 years, 169.8 +/- 7.4 cm, and 79.9 +/- 4.4 kg) who had not performed any resistance training for at least 1 year, were recruited for this study. All subjects performed 10 sets of 6 maximal voluntary eccentric actions of the elbow flexors of one arm against the lever arm of an isokinetic dynamometer moving at a constant velocity of 90 degrees .s. Changes in maximal voluntary isometric and isokinetic torque, range of motion, upper arm circumference, plasma creatine kinase activity, and muscle soreness before, immediately after, and for 5 days after exercise were compared between groups. The trained group showed significantly (P < 0.05) smaller changes in all of the measures except for muscle soreness and faster recovery of muscle function compared with the untrained group. For example, muscle strength of the trained group recovered to the baseline by 3 days after exercise, where the untrained group showed approximately 40% lower strength than baseline. These results suggest that resistance-trained men are less susceptible to muscle damage induced by maximal eccentric exercise than untrained subjects.  相似文献   

11.
This study aimed to evaluate the validity and test–retest reliability of trunk muscle strength testing performed with a latest-generation isokinetic dynamometer. Eccentric, isometric, and concentric peak torque of the trunk flexor and extensor muscles was measured in 15 healthy subjects. Muscle cross sectional area (CSA) and surface electromyographic (EMG) activity were respectively correlated to peak torque and submaximal isometric torque for erector spinae and rectus abdominis muscles. Reliability of peak torque measurements was determined during test and retest sessions. Significant correlations were consistently observed between muscle CSA and peak torque for all contraction types (r = 0.74−0.85; P < 0.001) and between EMG activity and submaximal isometric torque (r  0.99; P < 0.05), for both extensor and flexor muscles. Intraclass correlation coefficients were comprised between 0.87 and 0.95, and standard errors of measurement were lower than 9% for all contraction modes. The mean difference in peak torque between test and retest ranged from −3.7% to 3.7% with no significant mean directional bias. Overall, our findings establish the validity of torque measurements using the tested trunk module. Also considering the excellent test–retest reliability of peak torque measurements, we conclude that this latest-generation isokinetic dynamometer could be used with confidence to evaluate trunk muscle function for clinical or athletic purposes.  相似文献   

12.
Overweight and obese children demonstrate inferior motor performance for strength- and power-related activities requiring support or lifting of body weight. Our purpose here was to determine whether the inferior performance could be attributed to a lower strength to muscle area ratio in the obese. Eleven nonobese (16.6% fat) and 13 obese (35.5% fat) boys (9-13 years old) volunteered for the study. Peak torque was measured during voluntary isometric and isokinetic elbow flexion and knee extension at four joint angles and four velocities, respectively. The contractile properties, twitch torque, time to peak torque, and half-relaxation time were evoked for the elbow flexors by percutaneous stimulation. Elbow flexor and knee extensor cross-sectional areas (CSA) were determined by computed axial tomography taken at the mid-upper arm and mid-thigh, respectively. Isometric and isokinetic elbow flexion and knee extension strength normalized for body weight were significantly (p less than 0.05) higher in the nonobese compared to the obese boys. There were no significant (p greater than 0.05) differences, however, between groups for elbow flexor and knee extensor CSA or for absolute and relative (normalized for muscle CSA or the product of muscle CSA and height, the latter accounting for differences in moment arm length) isometric, isokinetic, or evoked twitch torque for elbow flexion or knee extension. Likewise, there were no differences between groups for the time-related contractile properties, time to peak torque, or half-relaxation time. These findings suggest that there is no difference in the intrinsic strength or contractile properties of the elbow flexor and knee extensor muscles between obese and nonobese pre-adolescent boys and that other factors, such as the handicapping effect of excess fat mass, probably account for the reduced motor performance of the obese child.  相似文献   

13.
A modified Cybex II isokinetic dynamometer was used to evaluate the problems associated with measuring the concentric force-velocity characteristics of human knee extensor muscles. Three contraction protocols were investigated, simple voluntary contractions (VC); releases from maximal voluntary isometric contractions (VR) and releases from. isometric femoral nerve stimulated contractions (FNR). Percutaneous stimulation of the quadriceps was unsuitable for dynamic contractions as the proportion of the muscle activated varied with the angle of knee flexion. Isometric length-tension relationships and isokinetic contractions at seven angular velocities between 0.5 and 5.2 rad · s–1 were recorded in five subjects. During isometric and slow dynamic contractions the voluntary forces were often greater than those obtained by femoral nerve stimulation, probably due to subjects stretching the rectus femoris during voluntary manoeuvres. It was found that the VC protocol produced acceptable isokinetic force recordings only at velocities below 3.1 rad · s–1 in most subjects whilst VR contractions resulted in unexpectedly low forces at velocities below 1.57 rad · s–1. Of the three techniques employed, FNR, although uncomfortable for subjects, provided the most accurate and reliable method of measuring force-velocity characteristics of knee extensor muscles. FNR contractions produced a force-velocity curve which showed a smooth decline in force with increasing velocity up to 5.2 rad · s–1. VC contractions appear to be an acceptable alternative for testing the muscles provided the angular velocity is less than 3.1 rad · s–1 and the subjects can be prevented from stretching the rectus femoris during the movement.  相似文献   

14.
The purpose of this study was to compare a piezoelectric contact sensor with an accelerometer for measuring the mechanomyographic (MMG) signal from the biceps brachii during submaximal to maximal isokinetic and isometric forearm flexion muscle actions. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), 10 adults (mean+/-SD age=22.8+/-2.7yrs) performed randomly ordered, submaximal step muscle actions of the dominant forearm flexors in 20% increments from 20% to 80% PT and MVC. Surface MMG signals were recorded simultaneously from a contact sensor and an accelerometer placed over the belly of the biceps brachii muscle. During the isokinetic and isometric muscle actions, the contact sensor and accelerometer resulted in linear increases in normalized MMG amplitude with torque (r(2) range=0.84-0.97) but the linear slope of the normalized MMG amplitude versus isokinetic torque relationship for the accelerometer was less (p<0.10) than that of the contact sensor. There was no significant (p>0.05) relationship for normalized MMG mean power frequency (MPF, %max) versus isokinetic and isometric torque for the contact sensor, but the accelerometer demonstrated a quadratic (R(2)=0.94) or linear (r(2)=0.83) relationship for the isokinetic and isometric muscle actions, respectively. There were also a number of significant (p<0.05) mean differences between the contact sensor and accelerometer for normalized MMG amplitude or MPF values. These findings indicated that in some cases involving dynamic and isometric muscle actions, the contact sensor and accelerometer resulted in different torque-related responses that may affect the interpretation of the motor control strategies involved.  相似文献   

15.
Recently, right and left output properties exerted from specific muscle groups have been evaluated using special measurement devices such as an isokinetic dynamometer. However, it remains unclear whether the coach can properly evaluate muscle function corresponding to lateral specificity in athletes. This study aimed to examine the different output properties between the dominant (D) and nondominant (ND) upper limbs as measured by muscle function tests with various muscle contraction patterns. Fifteen right-handed young men participated in this study. Each subject carried out isometric, isokinetic, and isotonic muscle power tests by elbow flexion with right and left arms. When calculating the laterality index, the laterality of the isotonic test (1.17) was the highest. In all tests, significant correlations were found between the measurements of the D and ND limbs. The isometric test was the highest (r = 0.93), followed by the isokinetic test (r = 0.66-0.83) and the isotonic test (r = 0.55). To examine the ratio of the laterality of measurements provided by each muscle function test, each measurement was converted to a standard score (Z-score). There were significant differences between D and ND limbs in the isometric (D:ND = 55.0:45.0) and the isotonic (54.1:45.9) tests but not in the isokinetic test (60°·s?1, 51.4:48.6; 180°·s?1, 50.7:49.2; 300°·s?1, 51.8:48.2). Particularly, the D (right) limb exerted greater muscle power in the isometric and the isotonic tests than in the isokinetic test. Occupational therapists or strength and conditioning professionals should understand that the D-ND differences shown by these muscle function tests may differ because of measurement conditions.  相似文献   

16.
Maximal voluntary isometric torque–angle relationships of elbow extensors and flexors in the transverse plane (humerus elevation angle of 90°) were measured at two different horizontal adduction angles of the humerus compared to thorax: 20° and 45°. For both elbow flexors and extensors, the torque–angle relationship was insensitive to this 25° horizontal adduction of the humerus. The peak in torque–angle relationship of elbow extensors was found at 55° (0° is full extension). This is closer to full elbow extension than reported by researchers who investigated this relationship in the sagittal plane. Using actual elbow angles during contraction, as we did in this study, instead of angles set by the dynamometer, as others have done, can partly explain this difference.We also measured electromyographic activity of the biceps and triceps muscles with pairs of surface electrodes and found that electromyographic activity level of the agonistic muscles was correlated to measured net torque (elbow flexion torque: Pearson’s r = 0.21 and extension torque: Pearson’s r = 0.53). We conclude that the isometric torque–angle relationship of the elbow extensors found in this study provides a good representation of the force–length relationship and the moment arm–angle relationship of the elbow extensors, but angle dependency of neural input gives an overestimation of the steepness.  相似文献   

17.
Based on the limited ability of the human being to voluntarily control submaximal eccentric exertions, previous studies have indicated that isokinetic testing with a combined concentric–eccentric exercise protocol could effectively identify submaximal (feigned) effort in various muscle groups by showing an abnormally high eccentric to concentric ratio (ECR). The objective of this study was to determine the validity and accuracy of an ECR-based isokinetic test in identifying feigned ankle weakness. Thirty-eight normal subjects performed maximal and feigned efforts in an isokinetic concentric and eccentric ankle plantar- and dorsiflexion protocol with two different velocities, 30 and 120° s−1. The isokinetic parameters ECR and the derivatives DEC (difference between ECR at high speed of motion and ECR at low speed of motion) and SEC (sum of ECR at high speed of motion plus the ratio between eccentric peak torque at high speed and concentric peak torque at low speed) were calculated. The ECR, DEC and SEC scores were significantly greater in feigned conditions for ankle plantarflexion, but not for dorsiflexion. Using optimal cutoff scores based on 99% tolerance intervals, it was disclosed that the most efficient parameter was the SEC, identifying 92% of the feigned efforts with 99% confidence, indicating that the ankle plantarflexors are less controllable in fast eccentric conditions than that in concentric conditions. The ECR-based parameters are valid for effectively identifying feigned plantarflexion effort with high accuracy, but do not allow the detection of feigned dorsiflexion weakness.  相似文献   

18.
The purpose of this study was to examine the effects of interelectrode distance (IED) on the absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) versus isokinetic and isometric torque relationships for the biceps brachii muscle. Ten adults [mean+/-SD age=22.0+/-3.4 years] performed submaximal to maximal, isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects performed randomly ordered, submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Surface EMG signals were recorded simultaneously from bipolar electrode arrangements placed over the biceps brachii muscle with IEDs of 20, 40, and 60mm. Absolute and normalized EMG amplitude (muVrms and %max) increased linearly with torque during the isokinetic and isometric muscle actions (r(2) range=0.988-0.998), but there were no significant changes for absolute or normalized EMG MPF (Hz or %max) from 10% to 100% PT and MVC. In some cases, there were significant (p<0.05) differences among the three IED arrangements for absolute EMG amplitude and MPF values, but not for the normalized values. These findings suggested that for the biceps brachii muscle, IEDs between 20 and 60mm resulted in similar patterns for the EMG amplitude or MPF versus dynamic and isometric torque relationships. Furthermore, unlike the absolute EMG amplitude and MPF values, the normalized EMG data were not influenced by changes in IED between 20 and 60mm. Thus, normalized EMG data can be compared among previous studies that have utilized different IED arrangements.  相似文献   

19.
The effects of increased muscle temperature via continuous ultrasound prior to a maximal bout of eccentric exercise were investigated on the symptoms of delayed onset muscle soreness (DOMS) of the elbow flexors. Perceived muscle soreness, upper arm circumferences, range of motion (ROM), and isometric and isokinetic strength were measured over 7 days on 14 college-aged men (n = 6) and women (n = 8). Ten minutes of continuous ultrasound (ULT) or sham-ultrasound (CON) were administered. Muscle temperature was measured in the biceps brachii of both arms. Muscle temperature increased by 1.79 degrees +/- 0.49 degrees C (mean +/- SD) in the experimental arm of the ULT group. Muscle soreness was induced by a single bout of 50 maximal eccentric contractions. The ULT group did not differ significantly (p < 0.05) from the CON group with respect to perceived muscle soreness, upper arm circumference, ROM, and isometric and isokinetic strength. In conclusion, increased muscle temperature failed to provide significant prophylactic effects on the symptoms of DOMS.  相似文献   

20.
It remains unclear if the sizes of higher-threshold motor units (MU) are associated with muscular strength and power. Therefore, the purpose of this study was to examine sex-related differences in muscle cross-sectional area (mCSA), percent myosin heavy chain (%MHC) isoform expression, and the MU action potential amplitudes (MUAPAMPS)-recruitment threshold (RT) relationships of the vastus lateralis and isometric peak torque, isokinetic peak torque and mean power at 1.05 rad·s−1 of the leg extensors. Surface electromyographic decomposition techniques were used to quantify MUAPAMPS recorded during isometric muscle actions at 70% of maximal voluntary contractions and regressed against RTs with the slopes calculated. Ultrasound images were used to measure mCSA. Males had greater slopes from the MUAPAMP-RT relationship than the females (P < 0.05). The greater slopes likely reflected larger higher-threshold MUs for the males. The mCSAs and slopes from the relationships were strongly correlated with isometric and isokinetic peak torque and isokinetic mean power (r = 0.78–0.82), however, type I %MHC isoform was only moderately correlated with isometric peak torque (r = −0.54). The results indicated that sex-related differences in muscular strength and power were associated more so with the sizes of the higher-threshold MUs (slopes) and mCSA than MHC isoforms. The amount of cross-bridge activity within muscle fibers that comprise higher-threshold MUs may be the primary contributor to muscular strength and power rather than the contractile properties of the muscle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号