Background

The implantable cardioverter defibrillator (ICD) is effective in preventing sudden cardiac death. However, in elderly patients (aged 75 years or older) the role of ICDs is still not well-defined and controversial.

Methods

We retrospectively analysed all clinical and survival data of all ICD patients who were ≥75 years at the date of implantation in the Erasmus MC, Rotterdam, the Netherlands and the University Hospital, Basel, Switzerland. Kaplan-Meier survival analysis was performed, and mortality predictors were identified. Mortality of the cohort was compared with a random sample of patients aged 60–70 years originating from the same database and to an age- and sex-matched cohort of Dutch persons.

Results

The study cohort consisted of 179 patients aged 75 years or older who were implanted between February 1999 and July 2008. The median follow-up time was 2.0 (IQR 2.8) years. Survival rates after 1, 2 and 3 years were 87, 82, 75 %, respectively. Survival was similar for primary and secondary prevention. Mortality in this study population could be predicted by combining four clinical risk factors: QRS duration >120 ms, NYHA class > II, renal failure and atrial fibrillation (AF). Survival was worse compared with the group of ICD patients aged 60–70 years and to the age- and sex-matched group of elderly persons. However, survival was not significantly worse when comparing elderly ICD patients without additional risk factors to the general population.

Conclusions

Elderly patients still have an acceptable survival probability independent of prevention indication, certainly if there are no additional clinical risk factors. The presence or absence of additional clinical risk factors should be taken into account when making the decision for implantation, since they strongly correlate with survival.  相似文献   

2.

Background

The benefit of implantable defibrillators (ICDs) for primary prevention remains debated. We analysed the implications of prophylactic ICD implantation according to the guidelines in 2 tertiary hospitals, and made a healthcare utilisation inventory.

Methods

The cohort consisted of all consecutive patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM) receiving a primary prophylactic ICD in a contemporary setting (2004–2008). Follow-up was obtained from hospital databases, and mortality checked at the civil registry. Additional data came from questionnaires sent to general practitioners.

Results

There were no demographic differences between the 2 centres; one had proportionally more CAD patients and more resynchronisation therapy (CRT-D). The 587 patients were followed over a median of 28 months, and 50 (8.5%) patients died. Appropriate ICD intervention occurred in 123 patients (21%). There was a small difference in intervention-free survival between the 2 centres. The questionnaires revealed 338 hospital admissions in 52% of the responders. Device-related admissions happened on 68 occasions, in 49/276 responders. The most frequently reported ICD-related admission was due to shocks (20/49 patients); for other cardiac problems it was mainly heart failure (52/99). Additional outpatient visits occurred in 19%.

Conclusion

Over a median follow-up of 2 years, one fifth of prophylactic ICD patients receive appropriate interventions. A substantial group undergoes readmission and additional visits. The high number of admissions points to a very ill population. Overall mortality was 8.5%. The 2 centres employed a similar procedure with respect to patient selection. One centre used more CRT-D, and observed more appropriate ICD interventions.  相似文献   

3.

Background

Young implantable cardioverter-defibrillator (ICD) patients are prone to complications and inappropriate shocks (IAS). The subcutaneous ICD (S-ICD) may avoid lead-related complications. This study aims to describe the incidence and nature of device-related complications in young transvenous ICD (TV-ICD) and S?ICD patients.

Methods

Single-chamber TV-ICD and S?ICD patients up to and including the age of 25 years implanted between 2002 and 2015 were retrospectively analysed. Complications were defined as device-related complications requiring surgical intervention. IAS were defined as shocks for anything other than ventricular tachycardia or ventricular fibrillation. Follow-up data were collected 5 years post-implantation. Kaplan-Meier estimates for complications at 5?year follow-up were calculated with a corresponding 95% confidence interval.

Results

Eighty-one patients (46 TV-ICD, 35 S-ICD) were included (median age 19.0 (IQR 16.0–23.0) and 16.5 (IQR 13.0–20.2) years respectively). Median follow-up was 60 and 40 months respectively. All-cause complication rate was 34% in the TV-ICD group and 25% in the S?ICD group (p?=?0.64). TV-ICD patients had more lead complications: 23% (10–36%) versus 0% (p?=?0.02). The rate of infections did not differ between TV-ICD and S?ICD: 2% (0–6%) versus 10% (0–21%) (p?=?0.15). No systemic infections occurred in the S?ICD patients. The rates of IAS were similar, TV-ICD 22% (9–35%) versus S?ICD 14% (0–30%) (p?=?0.40), as were those for appropriate shocks: 25% (11–39%) versus 27% (6–48%) (p?=?0.92).

Conclusion

The rates of all-cause complications in this cohort were equal, though the nature of the complications differed. S?ICD patients did not suffer lead failures or systemic infections. An era effect is present between the two groups.
  相似文献   

4.

Background

Timely detection of atrial fibrillation (AF) in implantable cardioverter defibrillator (ICD) patients is clinically important for prevention of AF-related complications and inappropriate shocks. Patients with coronary artery disease (CAD) and a dual or triple chamber ICD show a high incidence of device-detected AF. Whether CAD patients with a single chamber ICD carry a similar risk for device-detected AF remains unknown.

Study design

The INDICO AF trial is an investigator-initiated, multicentre, observational study evaluating the incidence of subclinical AF (SCAF) in CAD patients who will receive a single chamber ICD as primary prevention for sudden cardiac death (SCD). Fifty patients will receive a single chamber ICD with an integrated RR interval based AF detection algorithm. In combination with remote monitoring, rhythm data will be collected monthly. The primary endpoint is the incidence of SCAF at 1 year of follow-up; secondary endpoints include time until 10 and 20% of the patients have a first episode of SCAF. All patients in whom SCAF is detected will be invited for an outpatient visit and will receive adequate anticoagulation treatment when appropriate according to the CHA2DS2-VASc score and current guidelines.

Conclusion

The INDICO AF trial will quantify the incidence of SCAF in patients with an ICD and CAD. The study will underscore the clinical value of SCAF detection in single chamber ICD patients using remote patient monitoring and may improve patient care. This trial is registered at trialregister.nl with trial NTR6910.
  相似文献   

5.

Aims

To analyse the impact of device and software updates on the prevention of T?wave oversensing (TWOS) and inappropriate shocks (IS) in subcutaneous ICD (S-ICD) patients.

Background

TWOS is a feared complication after implantation. It may lead to harmful IS. To date, specific strategies to reduce these events are lacking.

Methods

In this retrospective single-centre trial we analysed 146 S?ICD patients who were implanted between 2010 and 2016. In all eligible consecutive patients (n?=?139), follow-up of at least 6 weeks was studied. The incidence of TWOS/IS was analysed in patients receiving a 2nd generation S?ICD (Emblem-S-ICD) between 2014 and 2016 (Emblem). Their outcome was compared with a control group (SQ) treated with the SQ1010 device between 2010 and 2014, who were followed up for a maximum of 2 years. Furthermore, to test if the software update SMR8 reduces inappropriate shocks in the SQ1010-S-ICD population, the incidence of TWOS/IS was evaluated before and after update installation.

Results

Basic characteristics and indications for S?ICD implantation were similar in both groups. However, the cumulative incidence of TWOS/IS was significantly decreased in Emblem vs. SQ (SQ: 15.4%, n?=?14/91 vs. Emblem 4.2%, n?=?2/48; p?=?0.049). Furthermore, with regards to the SQ population we also observed a trend towards a significant reduction of TWOS/IS after installation of the software update SMR8 in 2014 (before update: 13.4%, n?=?11/82 vs. after update: 4.6%, 3/65, p?=?0.07).

Conclusion

2nd generation devices but probably also the SMR8 software update reduce the incidence of TWOS/IS in S?ICD patients.
  相似文献   

6.

Background

A growing literature suggests underutilization of the primary prevention implantable cardioverter-defibrillator (ICD); thus, factors influencing utilization need to be understood. We performed a comprehensive assessment of patient characteristics and health insurance status among subjects eligible for primary prevention ICD in a tertiary care center.

Methods

From among a group of patients who met criteria for primary prevention ICD based on left ventricular dysfunction (LVEF ≤ 35%), ICD recipients (n = 110) were compared to ICD non-recipients (n = 110) to identify determinants of ICD implantation. We evaluated demographics, clinical profile including Charlson Comorbidity Index [CCI, categorized as low (≤3) or high (>3)] and health insurance status.

Results

ICD recipients were younger (62.1±15.0 vs. 68.0±18.2; P = 0.01), with more males (80% vs. 65.5%; P = 0.01), higher NYHA class (II/III: 75.5% vs. 40.2%; P<0.001) and more likely to have supplemental private health insurance (61.8% vs. 46.4%; P = 0.02). CCI was not significantly different between the two groups (low CCI 61.8% vs. 62.7%; P = 0.89). In multivariable analysis, factors independently associated with ICD implantation were male sex (OR, 2.77, [1.31-5.85]; P = 0.01), age<75 (OR, 2.68, [1.30-5.50]; P = 0.01), private insurance (OR, 2.17, [1.08-4.36], P = 0.03) and NYHA Class II/III (OR, 5.91, [2.91-12.01]; P<0.001). Documentation of discussion about primary prevention ICD was absent in the majority (57.2%) of non-recipients.

Conclusion

In a contemporary urban tertiary care setting, age, sex and heart failure symptom class were associated with ICD utilization, with socioeconomic/insurance status also potentially playing a role. These findings have implications for optimizing appropriate utilization of the prophylactic ICD and warrant follow-up in larger, more diverse populations.  相似文献   

7.

Background

Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful.

Aim

Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS.

Method

A retrospective single-centre analysis of 250 patients with either dual chamber (DR) ICDs or biventricular ICDs (CRTDs) over a (41.9 ± 27.3) month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming.

Results

39 events of anti-tachycardial pacing (ATP) and/or shocks were identified in 20 patients (8% incidence rate among patients). The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%). Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43%) of the secondary indication group experienced inappropriate therapies.

Conclusions

The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation.  相似文献   

8.

Background

Dutch patients with an implantable cardioverter defibrillator (ICD) are restricted from driving for two months after implantation or shocks. This requires significant lifestyle adjustments and is one of the primary concerns of ICD patients. Previous studies indicated that compliance with the driving restrictions is poor, but insight in socio-demographic, clinical and psychological factors associated with compliance is limited. Hence, this study aimed to explore compliance with the driving restrictions and associated factors in a large sample of Dutch ICD patients.

Method

Dutch ICD patients (N = 313) completed an elaborative set of questionnaires at time of implantation and at four months after implantation, assessing socio-demographic, psychological and driving-related characteristics. Clinical data were collected from the patients’ medical records.

Results

A substantial subgroup (28%) of the patient sample (median age 64 (interquartile range = 55–71), 81% male) reported to have been noncompliant with the driving restrictions. Univariate analysis indicated that noncompliant patients more often considered refusing the ICD due to the restrictions, compared to compliant patients (19% versus 10%, p = 0.02). Multivariate analysis showed that the feeling of understanding the reason behind the driving restrictions was associated with better compliance (odds ratio = 2.16, 95% confidence interval 1.02–4.56, p = 0.04). No other socio-demographic, clinical, psychological or driving-related factors were associated with compliance.

Conclusion

A large number of ICD patients does not comply with the driving restrictions after implantation. This study emphasised the importance of the patient’s feeling of understanding the reason behind the restrictions.
  相似文献   

9.

Background

Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will eventually receive appropriate ICD therapy.

Methods/design

The DO-IT Registry is a nationwide prospective cohort with a target enrolment of 1,500 primary prevention ICD patients with reduced left ventricular function in a setting of structural heart disease. The primary outcome measures are death and appropriate ICD therapy for ventricular tachyarrhythmias. Secondary outcome measures are inappropriate ICD therapy, death of any cause, hospitalisation for ICD related complications and for cardiovascular reasons. As of December 2016, data on demographic, clinical, and ICD characteristics of 1,468 patients have been collected. Follow-up will continue up to 24 months after inclusion of the last patient. During follow-up, clinical and ICD data are collected based on the normal follow-up of these patients, assuming ICD interrogations take place every six months and clinical follow-up is once a year. At baseline, the mean age was 66 (standard deviation [SD] 10) years and 27% were women.

Conclusion

The DO-IT Registry represents a real-world nationwide cohort of patients receiving ICDs for primary prevention of sudden cardiac death with reduced left ventricular function in a setting of structural heart disease. The registry investigates the efficacy of the current practice and aims to develop prediction rules to identify subgroups who will not (sufficiently) benefit from ICD implantation and to provide results regarding costs and budget impact of targeted supply of primary preventions ICDs.
  相似文献   

10.

Background

Coronary artery spasm may be the underlying mechanism in up to 10% of cases of acute coronary syndrome (ACS) and sudden cardiac death. Asian individuals exhibit a 3-times greater incidence of spasm than Caucasians; this is likely due to different types of mechanisms. Consequently, solid data is limited about the long-term prognosis in Caucasian patients presenting with ACS and/or out-of-hospital cardiac arrest (OHCA) caused by coronary spasm.

Methods

Between 2002 and 2015, thirty Caucasian patients with coronary artery spasm presenting with ACS (N = 29) and/or OHCA (N = 11) were enrolled in this prospective registry. Follow-up, consisting of regular outpatient visits, was conducted with a mean follow-up period of 7.5 ± 3.3 years. Outcomes included presence of stable angina pectoris, recurrence of ACS, occurrence of implantable cardioverter defibrillator (ICD) shocks and death.

Results

The majority of patients (60%) remained asymptomatic during the entire follow-up period. At the end of the follow-up period only 3 patients still experienced stable angina (10%). Only 2 patients (7%) had a recurrent cardiac event, in which the ICD provided appropriate shock therapy. Half of the patients treated with stenting (N = 6), required re-interventions.

Conclusion

Coronary spasm with ACS and/or OHCA in a Caucasian patient cohort has a relatively benign prognosis in the majority of patients in long-term follow-up, if treated appropriately with medical therapy. Both the role of ICD in OHCA secondary to coronary spasm, and the efficacy of stenting to treat vasospastic angina, warrant further study in large-sized prospective clinical trials.
  相似文献   

11.

Background

Remote patient monitoring is a safe and effective alternative for the in-clinic follow-up of patients with cardiovascular implantable electronic devices (CIEDs). However, evidence on the patient perspective on remote monitoring is scarce and inconsistent.

Objectives

The primary objective of the REMOTE-CIED study is to evaluate the influence of remote patient monitoring versus in-clinic follow-up on patient-reported outcomes. Secondary objectives are to: 1) identify subgroups of patients who may not be satisfied with remote monitoring; and 2) investigate the cost-effectiveness of remote monitoring.

Methods

The REMOTE-CIED study is an international randomised controlled study that will include 900 consecutive heart failure patients implanted with an implantable cardioverter defibrillator (ICD) compatible with the Boston Scientific LATITUDE® Remote Patient Management system at participating centres in five European countries. Patients will be randomised to remote monitoring or in-clinic follow-up. The In-Clinic group will visit the outpatient clinic every 3–6 months, according to standard practice. The Remote Monitoring group only visits the outpatient clinic at 12 and 24 months post-implantation, other check-ups are performed remotely. Patients are asked to complete questionnaires at five time points during the 2-year follow-up.

Conclusion

The REMOTE-CIED study will provide insight into the patient perspective on remote monitoring in ICD patients, which could help to support patient-centred care in the future.  相似文献   

12.

Introduction

Blood biomarkers have the potential to monitor the severity of chronic heart failure (CHF). Studies correlating repeated measurements of blood biomarkers with repeatedly assessed New York Heart Association (NYHA) class over a prolonged follow-up period, and concomitantly investigating their associations with clinical endpoints, have not yet been performed.

Methods

Between 2011–2013, 263 CHF patients were included. At inclusion and subsequently every 3 months, we measured N?terminal pro-B-type natriuretic (NT-proBNP), high-sensitivity troponin T (Hs-TnT) and C?reactive protein (CRP), and assessed NYHA class. The primary endpoint comprised heart failure hospitalisation, cardiovascular mortality, cardiac transplantation or left ventricular assist device implantation. Time-dependent Cox models were used.

Results

Mean age was 67 ± 13 years, 72% were men and 27% were in NYHA class III–IV. We obtained 886 repeated measures (median 3 [IQR 2–5] per patient). The primary endpoint was reached in 41 patients during a median follow-up of 1.0 [0.6–1.4] year. Repeatedly measured NT-proBNP and Hs-TnT were significantly associated with repeatedly assessed NYHA class, whereas CRP was not (NT-proBNP: β [95% CI]: 1.56 [1.17–2.06]ln(ng/l) increase per point increase in NYHA class, p = 0.002; HsTNT: β [95% CI]: 1.58 [1.21–2.07]). Serially measured NT-proBNP (HR [95% CI]:2.86 [1.73–4.73]), CRP (1.69 [1.21–2.34]) and NYHA class (2.33 [1.51–3.62]) were positively and independently associated with the primary endpoint, whereas Hs-TnT lost statistical significance after multivariable adjustment. A model containing serially measured NYHA class and NT-proBNP displayed a C-index of 0.84, while serially measured NYHA class and CRP showed a C-index of 0.82.

Conclusion

Temporal NT-proBNP, CRP and NYHA class patterns are independently associated with adverse clinical outcome. Serially measured NT-proBNP and NYHA class are best suited for monitoring CHF outpatients.
  相似文献   

13.

Aims

There is a continuing search for new treatment options in patients who suffer from refractory angina pectoris to improve quality of life. Several studies have recently demonstrated promising results by stimulating angiogenesis using extracorporeal shockwave therapy in these patients. The purpose of this study is to quantitatively analyse the effect of extracorporeal shockwave therapy on myocardial perfusion in patients with refractory angina pectoris.

Methods

We included 15 patients with NYHA class 3–4 of whom 8 patients underwent baseline and follow-up cardiac magnetic resonance imaging (CMR). All patients received 9 shockwave treatments of their ischaemic zone over a period of 3 months.

Results

Quantitative analysis of myocardial perfusion using CMR revealed no significant improvement of myocardial perfusion after treatment (0.80 ± 0.22 vs 0.76 ± 0.31; p = 0.42). However, the total group of 15 patients did experience a significant improvement in NYHA class (p = 0.034) and reduction of nitroglycerin use (p = 0.012).

Conclusion

Although treatment with extracorporeal shockwave was associated with an improvement in NYHA class, we could not observe an improvement in myocardial ischaemic zone and perfusion with CMR. To unravel the exact mechanisms of shockwave treatment, more in vitro and animal studies as well as larger (placebo-controlled) studies are required.
  相似文献   

14.

Purpose

To assess the activity and safety of postoperative adjuvant immunotherapy with transfusion of cytokine-induced killer (CIK) cells combined with chemotherapy in patients with colorectal cancer.

Methods

We retrospectively studied 96 consecutive patients with colorectal cancer who were treated with resection between January 2010 and December 2012 as well as adjuvant chemotherapy. Twenty-one of these patients accepted at least 1 cycle of CIK cell transfusion for immunotherapy (CIK group). Disease free survival (DFS), immune cells and treatment related side effects were assessed. The patients were followed up until May 2013.

Results

By the end of follow-up, 10 patients (10.42 %) had died. Eighteen patients (18.75 %) had withdrawn. All the patients in the CIK group are still alive, and only 1 patient had withdrawn. Patients in the CIK group had significantly longer DFS than those in the control group [HR = 0.28, 95 % CI (0.09, 0.91), p = 0.034]. The 2-year DFS rates of patients in the CIK group and the control group were 59.65 ± 24.80 % and 29.35 ± 6.39 %, respectively. The CD4+/CD8+ ratios were significantly lower during the period of chemotherapy than those before chemotherapy (p = 0.0038), while the ratios were significantly higher during the period of CIK cell transfusion than those before CIK therapy (p = 0.0484). There were no immediate adverse reactions to the CIK cell transfusions.

Conclusion

Adjuvant transfusion of CIK cells prolongs DFS in patients with colorectal cancer.  相似文献   

15.

Objective

Adaptive immune effectors do not influence prognosis in vulvar squamous cell carcinoma (vSCC). Therefore, we tried to clarify the prognostic role of innate immunity and granzyme B-dependent cytotoxicity as defined by intratumoral infiltrates of natural killer cells (CD56+) and lymphocytes expressing granzyme B (GrB+).

Methods

We analyzed 76 primary vSCCs and 35 lymph node metastases that were obtained from 76 patients with a full clinical history. The distribution and density of GrB+ and CD56+ cells within cancer tissues were evaluated by immunohistochemistry and correlated with clinicopathological features, commonly recognized prognostic factors and overall survival (OS).

Results

CD56+ cells were mostly detected within the cancer nests, while GrB+ cells were predominant in the tumor stroma. Intraepithelial (IE) CD56+ infiltrates at the primary site were correlated with depth of invasion (r = 0.339, p = 0.003) and recurrence (r = 0.295, p = 0.011), while IE GrB+ infiltrates were correlated with tumor grade (r = 0.304, p = 0.009) and age (r = 0.333, p = 0.004). The primary cancer nests of metastatic patients were infiltrated more by intraepithelial (IE) CD56+ cells than were those of the non-metastatic patients (p = 0.05). The median OS was 41.16 months (range 1.7–98.43). High IE GrB+ infiltrates predicted longer OS among patients without metastases (p = 0.028). High IE CD56+ infiltrates were correlated with longer OS in metastatic cases (p = 0.009).

Conclusion

The combined cytotoxicity of innate and adaptive immune effectors infiltrating cancer nests (IE GrB+) predicts an improved clinical outcome among non-metastatic vSCC patients. The functional status of prognostic IE CD56+ infiltrates in immune escaped (metastatic) tumors requires further investigation.  相似文献   

16.

Background and aims

In the Jomoro district in Ghana, tree plantations were the first cause of deforestation in the past, drastically reducing the area occupied by primary forests. The aim of this study was to quantify soil organic carbon (SOC) losses due to a change in land use from primary forest to tree plantations (cocoa, coconut, rubber, oil palm) on the different substrates of the district. Secondary forests and mixed plantations were also included in the study.

Methods

Soils were sampled at different depths up to 100 cm along a series of chronosequences in each of the three substrates (Granite, Lower Birrimian and Tertiary Sands) present in the area.

Results

The highest SOC losses in the 0–30 cm layer were caused by the conversion of primary forests to tree plantations: cocoa ?61 % of the original SOC stock, coconut ?55 %, rubber ?35 % and oil palm 28 %, while mixed plantations and secondary forests showed a loss of 23 % and 21 % of the original SOC stock, respectively. C losses were less apparent from the entire profile (to a depth of 100 cm).

Conclusions

All conversions to tree plantations caused substantial SOC losses, comparable to the conversion of forests to agricultural systems. Secondary forests and mixed plantations were the only sustainable land uses that restricted SOC losses considerably.  相似文献   

17.

Key message

Efficient Agrobacterium -mediated genetic transformation for investigation of genetic and molecular mechanisms involved in inflorescence architectures in Cornus species.

Abstract

Cornus canadensis is a subshrub species in Cornus, Cornaceae. It has recently become a favored non-model plant species to study genes involved in development and evolution of inflorescence architectures in Cornaceae. Here, we report an effective protocol of plant regeneration and genetic transformation of C. canadensis. We use young inflorescence buds as explants to efficiently induce calli and multiple adventitious shoots on an optimized induction medium consisting of basal MS medium supplemented with 1 mg/l of 6-benzylaminopurine and 0.1 mg/l of 1-naphthaleneacetic acid. On the same medium, primary adventitious shoots can produce a large number of secondary adventitious shoots. Using leaves of 8-week-old secondary shoots as explants, GFP as a reporter gene controlled by 35S promoter and hygromycin B as the selection antibiotic, a standard procedure including pre-culture of explants, infection, co-cultivation, resting and selection has been developed to transform C. canadensis via Agrobacterium strain EHA105-mediated transformation. Under a strict selection condition using 14 mg/l hygromycin B, approximately 5 % explants infected by Agrobacterium produce resistant calli, from which clusters of adventitious shoots are induced. On an optimized rooting medium consisting of basal MS medium supplemented with 0.1 mg/l of indole-3-butyric acid and 7 mg/l hygromycin B, most of the resistant shoots develop adventitious roots to form complete transgenic plantlets, which can grow normally in soil. RT-PCR analysis demonstrates the expression of GFP transgene. Green fluorescence emitted by GFP is observed in transgenic calli, roots and cells of transgenic leaves under both stereo fluorescence microscope and confocal microscope. The success of genetic transformation provides an appropriate platform to investigate the molecular mechanisms by which the various inflorescence forms are developed in Cornus plants.  相似文献   

18.

Key message

Our study shows that the expression of AtCBF3 and AtCOR15A improved the chilling tolerance in transgenic eggplant.

Abstract

In an attempt to improve chilling tolerance of eggplant (Solanum melongena L) plants, Arabidopsis C-repeat binding factor 3 (AtCBF3) and cold-regulated 15A (AtCOR15A) genes both driven by an Arabidopsis RESPONSIVE TO DESSICATION 29A promoter (AtRD29A) were transferred into the plants of eggplant cultivar Sanyueqie. Two independent homozygous transgenic lines were tested for their cold tolerance. The leaves of the transgenic plants in both lines withered much slower and slighter than the wild-type plants after exposure to cold stress treatment at 2 ± 1 °C. The gene expression of AtCBF3 and AtCOR15A was significantly increased as well as the proline content and the levels of catalase and peroxidase activities, while the relative electrical conductivity and the malondialdehyde content were remarkably decreased in the transgenic plants compared with the wild type at 4 ± 0.5 °C. The results showed that the expression of the exogenous AtCBF3 and AtCOR15A could promote the cold adaptation process to protect eggplant plants from chilling stress.  相似文献   

19.
20.

Background

Some patients with congestive heart failure have greater improvement of cardiac remodelling after cardiac resynchronisation therapy (CRT) and they are identified as super-responders (SRs). It remains unclear if echocardiographic markers of dyssynchrony could accuratelly predict super-response to CRT. The aim of this study is to evaluate potential echocardiographic predictors associated with super-response to CRT.

Methods

Fifthy nine CRT patients (mean age 52.9?±?9.0 years, 88% men) with congestive heart failure (54% ischaemic and 46% non-ischaemic aetiology) II-IV NYHA functional class were enrolled. To assess mechanical dyssynchrony we evaluated interventricular mechanical delay, the maximum delay between peak systolic velocities of the septal and posterior walls of left ventricle, duration of left ventricular pre-ejection period (LVPEP), left ventricular and interventricular dyssynchrony by tissue Doppler imaging and systolic dyssynchrony index by 3D echocardiography. After six months the patients were assessed for response and classified as SRs (reduction in left ventricular end-systolic volume (LVESV) ≥30%, n?=?20) and non-SRs (reduction in LVESV <?30%, n?=?39) and baseline data were analyzed to identify the predictors.

Results

Both groups demonstrated significant improvement in NYHA functional class, increase in left ventricular ejection fraction and reduction in LVESV. All parameters of mechanical dyssynchrony at baseline were significantly higher in SR group. Multiple logistic regression analysis showed that LVPEP (HR 1.031; 95% CI 1.007–1.055; p?=?0.011) was an independent predictor for CRT super-response. In ROC curve analysis LVPEP with a cut-off value of 147 ms demonstrated 73.7% sensitivity and 75% specificity (AUC?=?0.753; p?=?0.002) for the prediction of super-response to CRT.

Conclusion

Greater mechanical dyssynchrony is associated with super-response to CRT in patients with congestive heart failure. It is probable that an LVPEP >?147 ms can be used as independent predictor of super-response.