首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
Although muscle–tendon slack length is a crucial parameter used in muscle models, this is one of the most difficult measures to estimate in vivo. The aim of this study was to determine the onset of the rise in tension (i.e., slack length) during passive stretching in both Achilles tendon and gastrocnemius medialis. Muscle and tendon shear elastic modulus was measured by elastography (supersonic shear imaging) during passive plantarflexion (0° and 90° of knee angle, 0° representing knee fully extended, in a random order) in 9 participants. The within-session repeatability of the determined slack length was good at 90° of knee flexion (SEM=3.3° and 2.2° for Achilles tendon and gastrocnemius medialis, respectively) and very good at 0° of knee flexion (SEM=1.9° and 1.9° for Achilles tendon and gastrocnemius medialis, respectively). The slack length of gastrocnemius medialis was obtained at a significantly lower plantarflexed angle than for Achilles tendon at both 0° (P<0.0001; mean difference=19.4±3.8°) and 90° of knee flexion (P<0.0001; mean difference=25.5±7.6°). In conclusion, this study showed that the joint angle at which the tendon falls slack can be experimentally determined using supersonic shear imaging. The slack length of gastrocnemius medialis and Achilles tendon occurred at different joint angles. Although reporting this result is crucial to a better understanding of muscle–tendon interactions, further experimental investigations are required to explain this result.  相似文献   

2.
Ankle foot orthoses (AFOs) are designed to improve gait for individuals with neuromuscular conditions and have also been used to reduce energy costs of walking for unimpaired individuals. AFOs influence joint motion and metabolic cost, but how they impact muscle function remains unclear. This study investigated the impact of different stiffness AFOs on medial gastrocnemius muscle (MG) and Achilles tendon (AT) function during two walking speeds. We performed gait analyses for eight unimpaired individuals. Each individual walked at slow and very slow speeds with a 3D printed AFO with no resistance (free hinge condition) and four levels of ankle dorsiflexion stiffness: 0.25 Nm/°, 1 Nm/°, 2 Nm/°, and 3.7 Nm/°. Motion capture, ultrasound, and musculoskeletal modeling were used to quantify MG and AT lengths with each AFO condition. Increasing AFO stiffness increased peak AFO dorsiflexion moment with decreased peak knee extension and peak ankle dorsiflexion angles. Overall musculotendon length and peak AT length decreased, while peak MG length increased with increasing AFO stiffness. Peak MG activity, length, and velocity significantly decreased with slower walking speed. This study provides experimental evidence of the impact of AFO stiffness and walking speed on joint kinematics and musculotendon function. These methods can provide insight to improve AFO designs and optimize musculotendon function for rehabilitation, performance, or other goals.  相似文献   

3.
Shear wave elastography (SWE) is a promising tool for estimating musculoskeletal tissue properties, but few studies have rigorously assessed its repeatability and sources of error. The objectives of this study were to assess: (1) the extent to which probe positioning error and human user error influence measurement accuracy, (2) intra-user, inter-user, and day-to-day repeatability, and (3) the extent to which active and passive conditions affect shear wave speed (SWS) repeatability. Probe positioning and human usage errors were assessed by acquiring SWE images from custom ultrasound phantoms. Intra- and inter-user repeatability were assessed by two users acquiring five trials of supraspinatus muscle and tendon SWE images from ten human subjects. To assess day-to-day repeatability, five of the subjects were tested a second time, approximately 24 h later. Imaging of the phantoms indicated high inter-user repeatability, with intraclass correlation coefficient (ICC) values of 0.68–0.85, and RMS errors of no more than 4.1%. SWE imaging of the supraspinatus muscle and tendon had high repeatability, with intra- and inter-user ICC values of greater than 0.87 and 0.73, respectively. Day-to-day repeatability demonstrated ICC values greater than 0.33 for passive muscle, 0.48 for passive tendon, 0.65 for active muscle, and 0.94 for active tendon. This study indicates the technique has good to very good intra- and inter-user repeatability, and day-to-day repeatability is appreciably higher when SWE images are acquired under a low level of muscle activation. The findings from this study establish the feasibility and repeatability of SWE for acquiring data longitudinally in human subjects.  相似文献   

4.
It has recently been shown that shear wave speed in tendons is directly dependent on axial stress. Hence, wave speed could be used to infer tendon load provided that the wave speed-stress relationship can be calibrated and remains robust across loading conditions. The purpose of this study was to investigate the effects of loading rate and fluid immersion on the wave speed-stress relationship in ex vivo tendons, and to assess potential calibration techniques. Tendon wave speed and axial stress were measured in 20 porcine digital flexor tendons during cyclic (0.5, 1.0 and 2.0 Hz) or static axial loading. Squared wave speed was highly correlated to stress (r2avg = 0.98) and was insensitive to loading rate (p = 0.57). The constant of proportionality is the effective density, which reflects the density of the tendon tissue and additional effective mass added by the adjacent fluid. Effective densities of tendons vibrating in a saline bath averaged 1680 kg/m3 and added mass effects caused wave speeds to be 22% lower on average in a saline bath than in air. The root-mean-square error between predicted and measured stress was 0.67 MPa (6.7% of maximum stress) when using tendon-specific calibration parameters. These errors increased to 1.31 MPa (13.1% of maximum stress) when calibrating based on group-compiled data from ten tendons. These results support the feasibility of calculating absolute tendon stresses from wave speed squared based on linear calibration relationships.  相似文献   

5.
Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical properties based on the propagation of remotely induced shear waves. The objective of this study is to validate SWE throughout the functional range of motion of skeletal muscle for three ultrasound transducer orientations. We hypothesized that combining traditional materials testing (MTS) techniques with SWE measurements will show increased stiffness measures with increasing tensile load, and will correlate well with each other for trials in which the transducer is parallel to underlying muscle fibers. To evaluate this hypothesis, we monitored the deformation throughout tensile loading of four porcine brachialis whole-muscle tissue specimens, while simultaneously making SWE measurements of the same specimen. We used regression to examine the correlation between Young′s modulus from MTS and shear modulus from SWE for each of the transducer orientations. We applied a generalized linear model to account for repeated testing. Model parameters were estimated via generalized estimating equations. The regression coefficient was 0.1944, with a 95% confidence interval of (0.1463–0.2425) for parallel transducer trials. Shear waves did not propagate well for both the 45° and perpendicular transducer orientations. Both parallel SWE and MTS showed increased stiffness with increasing tensile load. This study provides the necessary first step for additional studies that can evaluate the distribution of stiffness throughout muscle.  相似文献   

6.
The present study aimed to clarify the effects of knee joint angle on the behavior of the medial gastrocnemius muscle (MG) fascicles during eccentric plantar flexions. Eight male subjects performed maximal eccentric plantar flexions at two knee positions [fully extended (K0) and 90° flexed (K90)]. The eccentric actions were preceded by static plantar flexion at a 30° plantar flexed position and then the ankle joint was forcibly dorsiflexed to 15° of dorsiflexion with an isokinetic dynamometer at 30°/s and 150°/s. Tendon force was calculated by dividing the plantar flexion torque by the estimated moment arm of the Achilles tendon. The MG fascicle length was determined with ultrasonography. The tendon forces during eccentric plantar flexions were influenced by the knee joint angle, but not by the angular velocity. The MG fascicle lengths were elongated as the ankle was dorsiflexed in K0, but in K90 they were almost constant despite the identical range of ankle joint motion. These results suggested that MG fascicle behavior during eccentric actions was markedly affected by the knee joint angle. The difference in the fascicle behavior between K0 and K90 could be attributed to the non-linear force–length relations and/or to the slackness of tendinous tissues.  相似文献   

7.
Voice is the essential part of singing and speech communication. Voice disorders significantly affect the quality of life. The viscoelastic mechanical properties of the vocal fold mucosa determine the characteristics of the vocal folds oscillations, and thereby voice quality. In the present study, a non-invasive method was developed to determine the shear modulus of human vocal fold tissue in vivo via measurements of the mucosal wave propagation speed during phonation. Images of four human subjects' vocal folds were captured using high speed digital imaging (HSDI) and magnetic resonance imaging (MRI) for different phonation pitches, specifically fundamental frequencies between 110 and 440 Hz. The MRI images were used to obtain the morphometric dimensions of each subject's vocal folds in order to determine the pixel size in the high-speed images. The mucosal wave propagation speed was determined for each subject and at each pitch value using an automated image processing algorithm. The transverse shear modulus of the vocal fold mucosa was then calculated from a surface (Rayleigh) wave propagation dispersion equation using the measured wave speeds. It was found that the mucosal wave propagation speed and therefore the shear modulus of the vocal fold tissue were generally greater at higher pitches. The results were in good agreement with those from other studies obtained via in vitro measurements, thereby supporting the validity of the proposed measurement method. This method offers the potential for in vivo clinical assessments of vocal folds viscoelasticity from HSDI.  相似文献   

8.
The present study aimed to re-examine the influence of the isometric plantarflexors contraction on the Achilles tendon moment arm (ATMA) and the factors influencing the ATMA in three-dimensions. A series of coronal magnetic resonance images of the right ankle were recorded at foot positions of 10° of dorsiflexion, neutral position, and 10° of plantarflexion for the rest condition and the plantarflexors contraction condition at 30% maximal voluntary effort. The shortest distance between the talocrural joint axis and the line of action of the Achilles tendon force projected to the orthogonal plane of the talocrural joint axis was determined as the ATMA. The ATMA determined in the contraction condition was significantly greater by 8 mm than that determined in the rest condition. The talocrural joint axis was displaced anteriorly by 3 mm and distally by 2 mm due to the muscle contraction. As the same time, the line of action of the Achilles tendon force was displaced posteriorly by 5 mm and medially by 2 mm. These linear displacements of the talocrural joint axis and the line of action of the Achilles tendon force accounted for the difference in the ATMAs between the two conditions by 35.9 and 62.4%, respectively. These angular displacements accounted for the total of 0.4% increase in the ATMA. These results confirm the previous findings reported in two-dimensional studies and found that the linear displacement of the line of action of the Achilles tendon force is the primary source of the contraction-induced increase in the ATMA.  相似文献   

9.
Forefoot strike is increasingly being adopted by runners because it can better attenuate impact than rearfoot strike. However, forefoot strike may overload the plantar fascia and alter the plantar fascia elasticity. This study aimed to use ultrasound elastography to investigate and compare shear wave elasticity of the plantar fascia between rearfoot strikers and forefoot strikers. A total of 35 participants (21 rearfoot strikers and 14 forefoot strikers), who were free of lower limb injuries and diseases, were recruited from a local running club. Individual foot strike patterns were identified through the measured plantar pressure during treadmill running. The B-Mode ultrasound images and shear wave elastographic images of the plantar fascia were collected from each runner. Two independent investigators reviewed the images and examined the plantar fascia qualitatively and quantitatively. The results demonstrated an overall good agreement between the investigators in the image review outcomes (ICC:0.96–0.98, κ: 0.89). There were no significant differences in the fascial thickness (p = 0.50) and hypoechogenicity on the gray-scale images (p = 0.54) between the two groups. Shear wave elastography showed that forefoot strikers exhibited reduced plantar fascia elasticity compared to rearfoot strikers (p = 0.01, Cohen’s d = 0.91). A less elastic fascial tissue was more easily strained under loading. Tissue overstrain is frequently related to the incidence of plantar fasciitis. While further study is needed for firm conclusions, runners using forefoot strike were encouraged to enhance their foot strength for better protection of the plantar fascia.  相似文献   

10.
Warm-up exercises are often advocated prior to strenuous exercise, but the warm-up duration and effect on muscle–tendon behavior are not well defined. The gastrocnemius–Achilles tendon complexes of 18 subjects were studied to quantify the dynamic creep response of the Achilles tendon in-vivo and the warm-up dose required for the Achilles tendon to achieve steady-state behavior. A custom testing chamber was used to determine each subject's maximum voluntary contraction (MVC) during an isometric ankle plantar flexion effort. The subject's right knee and ankle were immobilized for one hour. Subjects then performed over seven minutes of cyclic isometric ankle plantar flexion efforts equal to 25–35% of their MVC at a frequency of 0.75 Hz. Ankle plantar flexion effort and images from dual ultrasound probes located over the gastrocnemius muscle–Achilles tendon and the calcaneus–Achilles tendon junction were acquired for eight seconds at the start of each sequential minute of the activity. Ultrasound images were analyzed to quantify the average relative Achilles tendon strain at 25% MVC force (ε25%MVC) for each minute. The ε25%MVC increased from 0.3% at the start of activity to 3.3% after seven minutes, giving a total dynamic creep of ~3.0%. The ε25%MVC increased by more than 0.56% per minute for the first five minutes and increased by less than 0.13% per minute thereafter. Therefore, following a period of inactivity, a low intensity warm-up lasting at least six minutes or producing 270 loading cycles is required for an Achilles tendon to reach a relatively steady-state behavior.  相似文献   

11.
Characterization of the elastic properties of a tendon could enhance the diagnosis and treatment of tendon injuries. The purpose of this study was to examine the correlation between the shear elastic modulus on the patellar tendon captured from a Supersonic Shear Imaging (SSI) and the tangent traction modulus computed from a Material testing system (MTS) on 8 fresh patellar pig tendons (Experiment I). Test–retest reliability of the shear elastic modulus captured from the SSI was established in Experiment II on 22 patellar tendons of 11 healthy human subjects using the SSI. Spearman Correlation coefficients for the shear elastic modulus and tangent traction modulus ranged from 0.82 to 1.00 (all p<0.05) on the 8 tendons. The intra and inter-operator reliabilities were 0.98 (95% CI: 0.93–0.99) and 0.97 (95% CI: 0.93–0.98) respectively. The results from this study demonstrate that the shear elastic modulus of the patellar tendon measured by the SSI is related to the tangent traction modulus quantified by the MTS. The SSI shows good intra and inter-operator repeatability. Therefore, the present study shows that SSI can be used to assess elastic properties of a tendon.  相似文献   

12.
The purpose of this study was to investigate the site- and sex-differences in the morphological and mechanical properties of the plantar fascia (PF) in humans. The thickness and shear wave velocity (SWV) of PF at five different sites between the medial calcaneal tubercle and the second toe were measured for 40 healthy young participants (20 males and 20 females) using supersonic shear imaging (SSI). The thickness and SWV measurements were highly repeatable (ICC ≥ 0.93). The proximal sites of PF around the calcaneal attachment were significantly thicker and stiffer (higher SWV values) than the middle and distal sites (p < 0.05). In addition, females had significantly thinner PF in proximal and middle sites than males, while being significantly stiffer in regardless of the sites, compared with males (p < 0.05). The results of the present study partly support previous findings on the site- and sex-differences in PF morphology, and further reveal inhomogeneity and sex-specificity of PF stiffness. The present study widely opens the possibility of evaluating PF functions in vivo.  相似文献   

13.
The sternocostal and clavicular regions of the pectoralis major are independently harvested to provide shoulder stability, but surgical decision making does not consider the biomechanical consequences that disinsertion of one fiber region over the other has on shoulder function. Differences in material properties between the fiber regions could influence which tissue is more optimal for surgical harvesting. The current study utilized ultrasound shear wave elastography (SWE) to investigate whether the in vivo material properties differ between the fiber regions. Shear wave velocities (SWVs) were collected from the sternocostal and clavicular fiber regions of the pectoralis major from ten healthy young male participants. Participants produced isometric shoulder torques of varying magnitudes (passive, 15%, and 30% MVC) and directions (horizontal and vertical adduction). Four shoulder positions encompassing different vertical abduction and external rotation angles were examined. One-way ANOVAs tested the hypotheses that differences in SWVs during rest existed between the fiber regions as a function of shoulder position, and differences in SWVs during contraction existed as a function of shoulder position and torque direction. In all shoulder positions, the clavicular region exhibited greater SWVs during rest than the sternocostal region (P < 0.001). In shoulder positions that did not include external rotation, the clavicular region exhibited greater SWVs during contraction when producing horizontal adduction torques (P < 0.001), while the sternocostal region exhibited greater SWVs during contraction when producing vertical adduction torques at 30% MVC (P < 0.01). Our results suggest that each fiber region of the pectoralis major provides unique contributions to passive and active shoulder function.  相似文献   

14.
The hamstring muscles frequently suffer injury during high-speed running, though the factors that make an individual more susceptible to injury remain poorly understood. The goals of this study were to measure the musculotendon dimensions of the biceps femoris long head (BFlh) muscle, the hamstring muscle injured most often, and to use computational models to assess the influence of variability in the BFlh’s dimensions on internal tissue strains during high-speed running. High-resolution magnetic resonance (MR) images were acquired over the thigh in 12 collegiate athletes, and musculotendon dimensions were measured in the proximal free tendon/aponeurosis, muscle and distal free tendon/aponeurosis. Finite element meshes were generated based on the average, standard deviation and range of BFlh dimensions. Simulation boundary conditions were defined to match muscle activation and musculotendon length change in the BFlh during high-speed running. Muscle and connective tissue dimensions were found to vary between subjects, with a coefficient of variation (CV) of 17±6% across all dimensions. For all simulations peak local strain was highest along the proximal myotendinous junction, which is where injury typically occurs. Model variations showed that peak local tissue strain increased as the proximal aponeurosis width narrowed and the muscle width widened. The aponeurosis width and muscle width variation models showed that the relative dimensions of these structures influence internal muscle tissue strains. The results of this study indicate that a musculotendon unit’s architecture influences its strain injury susceptibility during high-speed running.  相似文献   

15.
Shear wave elastography (SWE) has enhanced our ability to non-invasively make in vivo measurements of tissue elastic properties of animal and human tissues. Recently, researchers have taken advantages of acoustoelasticity in SWE to extract nonlinear elastic properties from soft biological tissues. However, most investigations of the acoustoelastic effects of SWE data (AE-SWE) rely on classic hyperelastic models for rubber-like (dry) materials. In this paper, we focus solely on understanding acoustoelasticity in soft hydrated tissues using SWE data and propose a straightforward approach to modeling the constitutive behavior of soft tissue that has a direct microstructural/macromolecular interpretation. Our approach incorporates two constitutive features relevant to biological tissues into AE-SWE: static dilation of the medium associated with nonstructural components (e.g. tissue hydration and perfusion) and finite extensibility derived from an ideal network of biological filaments. We evaluated the proposed method using data from an in-house tissue-mimicking phantom experiment, and ex vivo and in vivo AE-SWE data available in the SWE literature. In conclusion, predictions made by our approach agreed well with measurements obtained from phantom, ex vivo and in vivo tissue experiments.  相似文献   

16.
The objective of this study was to test the hypothesis that increasing the speed and inclination of the treadmill increases the peak Achilles tendon forces and their rates of rise and fall in force. Implantable force transducers (IFT) were inserted in the confluence of the medial and lateral heads of the left gastrocnemius tendon in 11 rabbits. IFT voltages were successfully recorded in 8 animals as the animals hopped on a treadmill at each of two speeds (0.1 and 0.3 mph) and inclinations (0 degrees and 12 degrees). Instrumented tendons were isolated shortly after sacrifice and calibrated. Contralateral unoperated tendons were failed in uniaxial tension to determine maximum or failure force, from which safety factor (ratio of maximum force to peak in vivo force) was calculated for each activity. Peak force and the rates of rise and fall in force significantly increased with increasing treadmill inclination (p<0.001). Safety factors averaged 30.8+/-7.5 for quiet standing, 7.0+/-2.9 for level hopping, and 5.2+/-0.7 for inclined hopping (mean+/-SEM). These in vivo force parameters will help tissue engineers better design functional tissue engineered constructs for rabbit Achilles tendon and other tendon repairs. Force patterns can also serve as input data for mechanical stimulation of tissue-engineered constructs in culture. Such approaches are expected to help accelerate tendon repair after injury.  相似文献   

17.
Although the influence of the series elastic element of the muscle–tendon unit on jump performance has been investigated, the corresponding effect of the parallel elastic element remains unclear. This study examined the relationship between the resting calf muscle stiffness and drop jump performance. Twenty-four healthy men participated in this study. The shear moduli of the medial gastrocnemius and the soleus were measured at rest as an index of muscle stiffness using ultrasound shear wave elastography. The participants performed drop jumps from a 15 cm high box. The Spearman rank correlation coefficient was used to examine the relationships between shear moduli of the muscles and drop jump performance. The medial gastrocnemius shear modulus showed a significant correlation with the drop jump index (jump height/contact time) (r = 0.414, P = 0.044) and jump height (r = 0.411, P = 0.046), but not with contact time (P > 0.05). The soleus shear modulus did not correlate with these jump parameters (P > 0.05). These results suggest that the resting medial gastrocnemius stiffness can be considered as one of the factors that influence drop jump performance. Therefore, increase in resting muscle stiffness should enhance explosive athletic performance in training regimens.  相似文献   

18.
目的:回顾性分析带腓肠肌腱膜的腓肠神经营养皮瓣修复KuwadeⅣ型跟腱缺损的临床病例,探讨其手术注意事项及治疗经验。方法:总结2008年5月-2013年8月收治的KuwadeⅣ型跟腱缺损19例,应用带腓肠肌腱膜的腓肠神经营养皮瓣进行一期修复。7例为新鲜损伤,12例为陈旧性缺损。19例跟腱缺损均伴有皮肤及软组织坏死,皮肤缺损范围为4.0 cm×6.0 cm-6.0cm×12.0 cm,跟腱缺损长度为5-9 cm,术中皮瓣切取范围为6.0 cm×5.5 cm-12.0 cm×8.0cm,腓肠腱膜切取范围5.5 cm×6.0cm-10.0 cm×6.0 cm;供区游离植皮修复。客观性评价指标包括关节跖屈、背伸动度及形态学,主观性评价采用AOFAS评分。结果:术后17例跟腱功能重建良好,2例感染控制不良,跟腱移植体部分坏死。皮瓣完全成活13例,创面Ⅰ期愈合。2例术后6天皮瓣远端表皮坏死,经换药后愈合。2例术后10天皮瓣远端部分坏死,经局部皮瓣移位修复愈合,2例感染控制不良者,皮瓣未愈合,移植跟腱部分坏死,经再次清创后,行阔筋膜条修复术,局部皮瓣移位修复。术后19例均获随访,随访时间6~24个月,平均18个月。术后皮瓣略臃肿,但不影响穿鞋,行走功能恢复良好,术后1年AOFAS评分平均80.31分。结论:带腓肠肌腱膜的腓肠神经营养皮瓣用于治疗KuwadeⅣ型跟腱缺损,可以同时修复皮肤及跟腱缺损,是一种较为理想的一期修复方法。  相似文献   

19.
Eight patients had reconstructive surgery for soft-tissue, associated Achilles tendon, and calcaneus defects on the posterior aspect of the ankle. In group A, those patients with skin, soft-tissue, and Achilles tendon loss were treated with free groin flaps that included sheets of the external oblique aponeurosis based on the superficial circumflex iliac vessel. The groin flap provided skin coverage, and the aponeurosis was rolled to form a tendon-like structure to replace the Achilles tendon. In group B, those patients with an additional calcaneus bone loss were treated with free iliac osteocutaneous flaps, together with the external oblique aponeurosis based on the deep circumflex iliac vessel. The iliac bone was then utilized to reconstruct the calcaneus defect. All composite free tissue transfers were successful, except in two group B patients who suffered partial skin loss. The advantages of this technique are (1) a single, one-stage procedure, (2) faster wound healing with fewer adhesions of the reconstructed Achilles tendon, and (3) good cosmesis and minimal morbidity at the donor site.  相似文献   

20.
During human running, short latency stretch reflexes (SLRs) are elicited in the triceps surae muscles, but the function of these responses is still a matter of controversy. As the SLR is primarily mediated by Ia afferent nerve fibres, various methods have been used to examine SLR function by selectively blocking the Ia pathway in seated, standing and walking paradigms, but stretch reflex function has not been examined in detail during running. The purpose of this study was to examine triceps surae SLR function at different running speeds using Achilles tendon vibration to modify SLR size. Ten healthy participants ran on an instrumented treadmill at speeds between 7 and 15 km/h under 2 Achilles tendon vibration conditions: no vibration and 90 Hz vibration. Surface EMG from the triceps surae and tibialis anterior muscles, and 3D lower limb kinematics and ground reaction forces were simultaneously collected. In response to vibration, the SLR was depressed in the triceps surae muscles at all speeds. This coincided with short-lasting yielding at the ankle joint at speeds between 7 and 12 km/h, suggesting that the SLR contributes to muscle stiffness regulation by minimising ankle yielding during the early contact phase of running. Furthermore, at the fastest speed of 15 km/h, the SLR was still depressed by vibration in all muscles but yielding was no longer evident. This finding suggests that the SLR has greater functional importance at slow to intermediate running speeds than at faster speeds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号