首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Base of tongue (BOT) is a difficult subsite to examine clinically and radiographically. Yet, anatomic delineation of the primary tumor site, its extension to adjacent sites or across midline, and endophytic vs. exophytic extent are important characteristics for staging and treatment planning. We hypothesized that ultrasound could be used to visualize and describe BOT tumors.

Methods

Transcervical ultrasound was performed using a standardized protocol in cases and controls. Cases had suspected or confirmed BOT malignancy. Controls were healthy individuals without known malignancy.

Results

100% of BOT tumors were visualized. On ultrasound BOT tumors were hypoechoic (90.9%) with irregular margins (95.5%). Ultrasound could be used to characterize adjacent site involvement, midline extent, and endophytic extent, and visualize the lingual artery. No tumors were suspected for controls.

Conclusions

Ultrasonography can be used to transcervically visualize BOT tumors and provides clinically relevant characteristics that may not otherwise be appreciable.  相似文献   

2.
In this article, membrane perforation of endothelial cells with attached microbubbles caused by exposure to single-shot short pulsed ultrasound is described, and the mechanisms of membrane damage and repair are discussed. Real-time optical observations of cell-bubble interaction during sonoporation and successive scanning electron microscope observations of the membrane damage with knowledge of bubble locations revealed production of micron-sized membrane perforations at the bubble locations. High-speed observations of the microbubbles visualized production of liquid microjets during nonuniform contraction of bubbles, indicating that the jets are responsible for cell membrane damage. The resealing process of sonoporated cells visualized using fluorescence microscopy suggested that Ca2+-independent and Ca2+-triggered resealing mechanisms were involved in the rapid resealing process. In an experimental condition in which almost all cells have one adjacent bubble, 25.4% of the cells were damaged by exposure to single-shot pulsed ultrasound, and 15.9% (∼60% of the damaged cells) were resealed within 5 s. These results demonstrate that single-shot pulsed ultrasound is sufficient to achieve sonoporation when microbubbles are attached to cells.  相似文献   

3.
Alekseev  S. I.  Ziskin  M. C.  Fesenko  E. E. 《Biophysics》2011,56(3):525-528
The possibility of using thermocouples for artifact-free measurement of skin temperature during millimeter-wave exposure was studied. The distributions of the specific absorption rate (SAR) in the human skin were calculated for different orientations of the thermocouple relative to the E vector of the electromagnetic field. It was shown that, at the parallel orientation of the thermocouple relative to the E-field, SAR significantly increased about the tip of the thermocouple, which could lead to overheating. At the perpendicular orientation of the thermocouple, SAR distortions were insignificant. The data obtained confirm that the skin temperature can be measured with a thermocouple during exposure, provided that the thermocouple is perpendicular to the E-field. For accurate determination of SAR from the initial rate of temperature rise, the kinetics measured with the thermocouple must be fitted with the bio-heat transfer equation.  相似文献   

4.
The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy are shown. Systems using both linear and non-linear propagation of ultrasound are described. The blood velocity can also be non-invasively visualized using ultrasound and the basic signal processing for doing this is introduced. Examples for spectral velocity estimation, color flow imaging and the new vector velocity images are presented.  相似文献   

5.
The purpose of this technical report is to describe a cost-effective and highly reliable methodology to measure mechanical and material properties of the Achilles tendon. Subjects are positioned on an isokinetic dynamometer time synchronized to a diagnostic ultrasound device. A tendon fascicle distal to the soleus is visualized during a ramped isometric maximal plantarflexion contraction. Excursion of the fascicle and tendon torque output yield a force-elongation curve in which mechanical characteristics and material properties are derived. Excellent intrasession and intersession reliabilities were observed for both the dynamometer (intraclass correlation coefficient [ICC] 0.99, 0.95) and excursion (ICC 0.99, 0.93) measures. Practical applications for this methodology include examination of training regimes for optimal tendon adaptation and rehabilitation in the presence of tendinopathy.  相似文献   

6.
Cryosurgery has become a well-established technique for the ablation of undesirable tissues such as tumors and cancers. The motivation for this study is to improve the efficacy and safety of this technique. This study presents an inverse heat transfer method for monitoring the motion of the freezing front from a cryoprobe. With the help of a thermocouple inserted into the layer of diseased tissue, the inverse heat transfer method estimates simultaneously the blood perfusion rate and the thermal conductivities of both frozen and unfrozen tissues. This information is then fed to the Pennes bioheat equation that: (1) calculates the time-varying temperature distribution inside the layer of tissue and (2) predicts the motion of the freezing front. The effect of the most influential parameters on the inverse predictions is investigated. These parameters are (1) the initial guesses for the unknown Levenberg-Marquardt polynomial parameters of the thermo-physical properties; (2) the temperature of the cryoprobe; (3) the heat transfer coefficient of the impinging jet of liquid nitrogen; and (4) the noise on the temperature data recorded by the thermocouple probe. Results show that the proposed inverse method is a promising alternative to ultrasound and Magnetic Resonance Imaging (MRI) for monitoring the motion of the freezing front during cryosurgery. For all the cryogenic scenarios simulated, the predictions of the inverse model remain accurate and stable.  相似文献   

7.
The cohesion-tension (CT) theory requires stability of liquid water in conducting elements under high tensions. This stability has been measured using different methods, some of which yielded contradictory results. In this study a method is presented to establish known tensions in the water inside conifer tracheids, to detect cavitation events under these conditions and to construct vulnerability curves. Tangential sapwood sections of Juniperus virginiana L. were placed closely over the surface of NaCl solutions with water potentials ranging from -0.91 to -7.57 MPa. Water potentials were measured with a thermocouple hygrometer in contact with the section, and ultrasound acoustic emissions (UAE) from the sections were registered with an ultrasound transducer. The emission rate of signals increased with the concentration of the solution. Exposure of 100 microm sections in the airspace over a solution provided optimal conditions for the rupture of the water column: many tracheid walls bordered on air, and water in the lumen came under high tension. Nevertheless, the water remained in the metastable liquid state for periods of many hours. The vulnerability obtained from simultaneous measurements of water potentials and ultrasound acoustic emissions on sapwood sections was substantially higher than from conventionally measured curves of detached branches. It is argued that the isolation of tracheids in a massive organ as well as the rate of potential decline will influence the probability of cavitations at a given water potential and thus the parameters of the vulnerability curve.  相似文献   

8.
USI of the pleural cavities was performed in 119 patients (65 men and 54 women) aged 30 to 90 with different abnormalities. Pleural fluid in 106 patients was the leading symptom of the main pathological process, in 13 patients it was a sign of pleural disease. USI was combined with routine x-ray methods. Minimum amounts of pleural fluid could be clearly visualized by ultrasound scanning. Echo-tomographic symptoms of free and encapsulated fluid as well as ultrasound signs permitted differentiation of pleural thickening and exudate accumulation. A program of diagnostic algorithm was worked out for pleural fluid.  相似文献   

9.
Mild hyperthermia has been successfully employed to induce reversible physiological changes that can directly treat cancer and enhance local drug delivery. In this approach, temperature monitoring is essential to avoid undesirable biological effects that result from thermal damage. For thermal therapies, Magnetic Resonance Imaging (MRI) has been employed to control real-time Focused Ultrasound (FUS) therapies. However, combined ultrasound imaging and therapy systems offer the benefits of simple, low-cost devices that can be broadly applied. To facilitate such technology, ultrasound thermometry has potential to reliably monitor temperature. Control of mild hyperthermia was previously achieved using a proportional-integral-derivative (PID) controller based on thermocouple measurements. Despite accurate temporal control of heating, this method is limited by the single position at which the temperature is measured. Ultrasound thermometry techniques based on exploiting the thermal dependence of acoustic parameters (such as longitudinal velocity) can be extended to create thermal maps and allow an accurate monitoring of temperature with good spatial resolution. However, in vivo applications of this technique have not been fully developed due to the high sensitivity to tissue motion. Here, we propose a motion compensation method based on the acquisition of multiple reference frames prior to treatment. The technique was tested in the presence of 2-D and 3-D physiological-scale motion and was found to provide effective real-time temperature monitoring. PID control of mild hyperthermia in presence of motion was then tested with ultrasound thermometry as feedback and temperature was maintained within 0.3°C of the requested value.  相似文献   

10.
The vulnerability of the xylem to cavitation is an important trait in plant drought resistance and has been quantified by several methods. We present a modified method for the simultaneous measurement of cavitations, recorded as ultrasound acoustic emissions (UAEs), and the water potential, measured with a thermocouple psychrometer, in small samples of conifer wood. Analyzing the amplitude of the individual signals showed that a first phase, during which the mean amplitude increased, was followed by a second phase with distinctly lower signal amplitudes. We provide a method to separate the two groups of signals and show that for many samples plausible vulnerability curves require rejecting late low-energy UAEs. These very likely do not result from cavitations. This method was used to analyze the differences between juvenile wood, and early and late mature wood in Picea abies (L.) Karst. Juvenile earlywood was more resistant to cavitation than mature earlywood or latewood, which we relate to the tracheid anatomy of the samples.  相似文献   

11.
《Theriogenology》2016,85(9):1611-1619
The study uniquely described the clinical value of transabdominal ultrasonography for monitoring features characterizing the estrous cycle in female cheetahs (Acinonyx jubatus). The reproductive tracts of 21 female, nulliparous, and relatively aged (median: 11 and interquartile range: 9.25–14 years) captive cheetahs resident on two sites in Namibia were assessed by transabdominal ultrasound. Subsequently, the ovarian findings on ultrasound were compared with direct visualization while performing laparoscopic sterilization. A combination of these observations supported by concurrent sampling for vaginal cytology and serum progesterone concentrations defined the estrous status of individual animals. At one site, six cheetahs had been implanted with the GnRH agonist, deslorelin as a contraceptive at least once within the preceding 11 years. On ultrasound, 31 uterine horns and 35 ovaries with discernible structures on 28 (86%) were visualized in the 21 cheetahs. The uterine body was difficult to visualize because of its intrapelvic location. Eleven of 19 uteri (58%) visualized showed endometrial edema suggestive of estrogenization. The uteri of four cheetahs (19%) showed evidence of mild cystic endometrial hyperplasia. Paraovarian cysts were seen on ultrasound (n = 21) and laparoscopy (n = 26) in 16 (76.2%) and 18 (85.7%) cheetahs, respectively. Ovarian volumes obtained from ultrasonographically determined dimensions predicted cyclic activity. Laparoscopy showed that 19 ovaries had discernible follicular structures. In the study population, 10 (47.6%) cheetahs were in proestrus or estrus; none in the luteal phase; and 11 (52.4%) in anestrus. Transabdominal ultrasound, in combination with serum progesterone concentrations and vaginal cytology, was used with acceptable accuracy to assess cyclic ovarian activity in captive cheetahs. A considerable proportion of this aged population showed ovarian activity and the prevalence of paraovarian cysts was notable. A history of prior deslorelin treatment was not associated with either reproductive activity or uterine pathology.  相似文献   

12.
Leaf water potentials measured with a pressure chamber   总被引:31,自引:17,他引:14       下载免费PDF全文
Boyer JS 《Plant physiology》1967,42(1):133-137
Leaf water potentials were estimated from the sum of the balancing pressure measured with a pressure chamber and the osmotic potential of the xylem sap in leafy shoots or leaves. When leaf water potentials in yew, rhododendron, and sunflower were compared with those measured with a thermocouple psychrometer known to indicate accurate values of leaf water potential, determinations were within ± 2 bars of the psychrometer measurements with sunflower and yew. In rhododendron. water potentials measured with the pressure chamber plus xylem sap were 2.5 bars less negative to 4 bars more negative than psychrometer measurements.

The discrepancies in the rhododendron measurements could be attributed, at least in part, to the filling of tissues other than xylem with xylem sap during measurements with the pressure chamber. It was concluded that, although stem characteristics may affect the measurements, pressure chamber determinations were sufficiently close to psychrometer measurements that the pressure chamber may be used for relative measurements of leaf water potentials, especially in sunflower and yew. For accurate determinations of leaf water potential, however, pressure chamber measurements must be calibrated with a thermocouple psychrometer.

  相似文献   

13.
The paper presents the authors' experience in using small pelvic MRI on an Ellipse low-field apparatus made in Russia. A total of 74 patients were examined. Abnormal formations in the small pelvic organs were visualized in 72 patients. The potentialities and limitations of MRI in visualizing small pelvic organs and their pathology are shown. The technique is compared with CT and ultrasound study.  相似文献   

14.
Accurate tool tracking is a crucial task that directly affects the safety and effectiveness of many interventional medical procedures. Compared to CT and MRI, ultrasound-based tool tracking has many advantages, including low cost, safety, mobility and ease of use. However, surgical tools are poorly visualized in conventional ultrasound images, thus preventing effective tool tracking and guidance. Existing tracking methods have not yet provided a solution that effectively solves the tool visualization and mid-plane localization accuracy problem and fully meets the clinical requirements. In this paper, we present an active ultrasound tracking and guiding system for interventional tools. The main principle of this system is to establish a bi-directional ultrasound communication between the interventional tool and US imaging machine within the tissue. This method enables the interventional tool to generate an active ultrasound field over the original imaging ultrasound signals. By controlling the timing and amplitude of the active ultrasound field, a virtual pattern can be directly injected into the US machine B mode display. In this work, we introduce the time and frequency modulation, mid-plane detection, and arbitrary pattern injection methods. The implementation of these methods further improves the target visualization and guiding accuracy, and expands the system application beyond simple tool tracking. We performed ex vitro and in vivo experiments, showing significant improvements of tool visualization and accurate localization using different US imaging platforms. An ultrasound image mid-plane detection accuracy of ±0.3 mm and a detectable tissue depth over 8.5 cm was achieved in the experiment. The system performance is tested under different configurations and system parameters. We also report the first experiment of arbitrary pattern injection to the B mode image and its application in accurate tool tracking.  相似文献   

15.

Background  

Endometrial cavity fluid (ECF) is a fluid accumulation within the endometrial cavity. The significance of ECF remains unclear during the program of in vitro fertilization-embryo transfer (IVF-ET). The aim of the present study was to investigate the associated factors to ECF, visualized through ultrasound at the day of oocyte retrieval, and the relevant impact on the outcome of IVF-ET.  相似文献   

16.
A 9-month old, female, stray dog was rescued and conducted to a university veterinary hospital. Moderate anemia was observed and abdominal ultrasound revealed pancreatitis. Right kidney was not visualized due to intestinal gas. Urinalysis was normal. Castration was performed three weeks later. Before discharge, abdominal ultrasound was performed for internal sutures examination. A cyst-like structure was present in the right retroperitoneal space with what appeared to be tubular worms inside it, not observed in previous evaluation. An ectopic dioctophymosis diagnosis was made. Two female Dioctophyme renale were surgically removed from the structure. Right kidney was hyperemic but not removed. No sign of peritonitis was observed. The dog recovered well. Laboratory follow-up showed no abnormalities a year after the episode and Doppler ultrasound revealed a mild right nephropathy. This is the first canine ectopic dioctophymosis case with only an abdominal cyst-like structure containing viable nematodes, successfully treated. It represents the rarity and difficulties in diagnosing ectopic dioctophymosis even in enzootic locations, highlighting the importance of ultrasonographic screening for such silent, potentially zoonotic disease.  相似文献   

17.
Rachides of Juglans regia L. (Juglandaceae) and one‐year‐old twigs of Evonymus latifolia (L.) Mill. (Celastraceae) were cooled in air to ?25 °C, with an ultrasound detector attached to the xylem where peripheral tissues had been peeled off. Ultrasound acoustic emissions started between ?4·5 and ?14·3 °C, as measured with a thermocouple inserted into the xylem. The number of emissions was significantly lower from saturated plant parts than from those frozen at field water potentials. Bench‐drying of saturated samples produced significantly less signals than the freezing protocols. These findings are in accordance with the hypothesis that freezing of xylem under tension induces cavitation events. They corroborate earlier work which tried to provide a logical explanation for the seemingly paradoxical cryo‐scanning electron microscope observations of changing vessel contents during a daycourse in the field.  相似文献   

18.
BACKGROUND: The purpose of this study was to investigate the feasibility of using high frequency ultrasound to study the chick embryo in a noninvasive and longitudinal fashion. METHODS: A total of 10 SPF White Leghorn chick embryos (GDs 11-17; Hamburger and Hamilton stage 37-43) were consecutively examined with a GE Logiq 400 ProSeries ultrasound unit using an 11-MHz small parts ultrasound probe. Access for ultrasound visualization of the embryos was accomplished by opening a 2-3-cm window either in the air cell over the blunt end of the egg or laterally over the embryo-dependent side of the egg. Warmed ultrasound coupling gel was used for imaging, and thermal regulation was maintained with infant heel warmers. The ultrasound images were recorded directly on digital video using a Sony TRV 900 DV camcorder. The images were directly converted to jpeg and mjeg2 files for further analysis. RESULTS: Effective visualization of each embryo was possible on each day of the study period. The embryos were best visualized through the opening made in the air cell at the blunt end of the egg. The extent of the anatomic survey of the chick embryo was dependent upon the position of the embryo in the egg relative to the opening in the air cell. Doppler color flow mapping studies were obtained of the embryonic and extraembryonic circulation. CONCLUSIONS: This preliminary investigation clearly shows the feasibility of high frequency ultrasound imaging to study chick embryo development in a longitudinal and noninvasive fashion. Further studies are presently ongoing regarding earlier embryo development, as well as to determine the stability and dynamics of the methodology.  相似文献   

19.
Easter  S. Joe  Sosebee  Ronald E. 《Plant and Soil》1974,40(3):707-712
Summary Use of Spanner thermocouple psychrometers to measure soil water potentials and internal water potentials of woody plants was studied using honey mesquite (Prosopis glandulosa var. glandulosa) growing under two soil water regimes. A high correlation (r=0.92 or greater) existed between the soil water potential (bars) measured with Spanner thermocouple psychrometers and soil water content (percent) obtained from gravimetric samples on a fine sandy loam soil. The influence of soil water potential and diurnal fluctuations were easily measured in honey mesquite growing under two soil water regimes. The results of this study indicated that thermocouple psychrometers can effectively be used in field studies involving soil-plant-water relationships. College of Agricultural Sciences Publication Number T-9-130. College of Agricultural Sciences Publication Number T-9-130.  相似文献   

20.
Wiebe HH 《Plant physiology》1981,68(6):1218-1221
Water activities (potentials) in plant materials were measured over the range from free water to oven dryness with a Spanner thermocouple psychrometer. In a two-step procedure, water was first condensed on the thermocouple junction for several minutes. The sample was then inserted under the wet thermocouple and the maximum psychrometric cooling was measured in about 10 seconds. Calibration was with saturated salt slurries of known water activities. Psychrometric cooling was a nearly linear function of the water activity and of the negative log of the water potential. The psychrometric cooling to water activity relationship agreed with wetbulb temperature depression to relative humidity relationships given in tables. Water activities of wheat grains and leaves decreased sharply in a curvilinear fashion as their water contents decreased. Some problems of the procedure are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号