首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
This laboratory has previously reported on the development of a flow cytometry-based method for scoring in vitro micronuclei in mouse lymphoma (L5178Y) cells [S.L. Avlasevich, S.M. Bryce, S.E. Cairns, S.D. Dertinger, In vitro micronucleus scoring by flow cytometry: differential staining of micronuclei versus apoptotic and necrotic chromatin enhances assay reliability, Environ. Molec. Mutagen. 47 (2006) 56-66]. With this method, necrotic and mid/late stage apoptotic cells are labeled with the fluorescent dye ethidium monoazide. Cells are then washed, stripped of their cytoplasmic membranes, and incubated with RNase plus a pan-nucleic acid dye (SYTOX Green). This process provides a suspension of free nuclei and micronuclei that are differentially stained relative to chromatin associated with dead/dying cells. The current report extends this line of investigation to include the human cell line TK6. Additionally, methods are described that facilitate simultaneous quantitative analysis of cytotoxicity, perturbations to the cell cycle, and what we hypothesize is aneuploidization. This comprehensive cytogenetic damage assay was evaluated with the following diverse agents: etoposide, ionizing radiation, methyl methanesulfonate, vinblastine, ethanol, and staurosporine. Cells were harvested after 30h of continuous treatment (in the case of chemicals), or following graded doses of radiation up to 1Gy. Key findings include the following: (1) Significant discrepancies in top dose selection were found for five of the six agents studied when relative survival measurements were based on Coulter counting versus flow cytometry. (2) Both microscopy- and flow cytometry-based scoring methods detected dose-dependent micronucleus formation for the four genotoxic agents studied, whereas no significant increases were observed for the presumed non-genotoxicants ethanol and staurosporine when top dose selection was based on flow cytometric indices of cytotoxicity. (3) SYTOX and ethidium monoazide fluorescence signals conveyed cell cycle and cell death information, respectively, and appear to represent valuable aids for interpreting micronucleus data. (4) The frequency of hypodiploid nuclei increased in response to each of the genotoxic agents studied, but not following exposure to ethanol or staurosporine. Collectively, these results indicate that a comprehensive assessment of genotoxicity and other test article-induced toxicities can be acquired simultaneously using a simple two-color flow cytometry-based technique.  相似文献   

2.
An international, multi-lab trial was conducted to evaluate a flow cytometry-based method for scoring micronuclei in mouse lymphoma L5178Y cells [S.L. Avlasevich, S.M. Bryce, S.E. Cairns, S.D. Dertinger, In vitro micronucleus scoring by flow cytometry: differential staining of micronuclei versus apoptotic and necrotic chromatin enhances assay reliability, Environ. Mol. Mutagen. 47 (2006) 56–66]. A reference laboratory investigated the potential of six chemicals to induce micronuclei—the genotoxicants mitomycin C (MMC), etoposide (ETOPO), and vinblastine (VB), and the non-genotoxicants sucrose (SUC), staurosporine (STS), and dexamethasone (DEX). The latter two non-genotoxicants were selected as extreme challenges to the assay because of their potent apoptogenic activity. Three collaborating laboratories were supplied with prototype In Vitro MicroFlow™ kits, and each was assigned one genotoxicant and one non-genotoxicant. Cells were treated continuously for 24 h over a range of concentrations up to 5 mg/ml, or overtly cytotoxic concentrations. Micronuclei were scored via standard microscopy and flow cytometry. In addition to enumerating micronucleus frequencies, a cytotoxicity measurement that is simultaneously acquired with the flow cytometric micronucleus scoring procedure was evaluated (Flow-NBR). With this method, latex particles served as counting beads, and facilitated relative survival measurements that exclude the presence of dead/dying cells. For comparison purposes, additional cytotoxicity endpoints were measured, including several that are based on cell number, and others that reflect compromised membrane integrity, including dye permeability and/or phospholipid distribution. Key findings for this set of compounds include the following: (1) significant discrepancies in top concentration selection were found when cytotoxicity measurements were based on different methods, with the Flow-NBR approach tending to be the most sensitive, (2) both microscopy- and flow cytometry-based scoring methods detected concentration-dependent micronucleus formation for the three genotoxic agents studied, with good agreement between the reference laboratory and the collaborating laboratories, and (3) whereas flow cytometric analyses showed no significant increases for the non-genotoxicants when top concentration selection was based on Flow-NBR, significantly elevated micronucleus frequencies were observed for concentrations that were chosen based on less-sensitive cytotoxicity assays. Collectively, these results indicate that rapid assessment of genotoxicity can be accomplished with a relatively simple flow cytometric technique, and that the scoring system is transferable across laboratories. Furthermore, a concurrent assessment of cytotoxicity, Flow-NBR, may help reduce the occurrence of irrelevant positive results, as it may represent a more appropriate means for choosing top concentration levels. Finally, the data presented herein reinforce concerns about the manner in which cytotoxicity limits are described in guidance documents, since these recommendations tend to cite fixed cut-off values without reference to methodology.  相似文献   

3.
An international, multi-lab trial was conducted to evaluate a flow cytometry-based method for scoring micronuclei in mouse lymphoma L5178Y cells [S.L. Avlasevich, S.M. Bryce, S.E. Cairns, S.D. Dertinger, In vitro micronucleus scoring by flow cytometry: differential staining of micronuclei versus apoptotic and necrotic chromatin enhances assay reliability, Environ. Mol. Mutagen. 47 (2006) 56-66]. A reference laboratory investigated the potential of six chemicals to induce micronuclei -- the genotoxicants mitomycin C (MMC), etoposide (ETOPO), and vinblastine (VB), and the non-genotoxicants sucrose (SUC), staurosporine (STS), and dexamethasone (DEX). The latter two non-genotoxicants were selected as extreme challenges to the assay because of their potent apoptogenic activity. Three collaborating laboratories were supplied with prototype In Vitro MicroFlow kits, and each was assigned one genotoxicant and one non-genotoxicant. Cells were treated continuously for 24h over a range of concentrations up to 5 mg/ml, or overtly cytotoxic concentrations. Micronuclei were scored via standard microscopy and flow cytometry. In addition to enumerating micronucleus frequencies, a cytotoxicity measurement that is simultaneously acquired with the flow cytometric micronucleus scoring procedure was evaluated (Flow-NBR). With this method, latex particles served as counting beads, and facilitated relative survival measurements that exclude the presence of dead/dying cells. For comparison purposes, additional cytotoxicity endpoints were measured, including several that are based on cell number, and others that reflect compromised membrane integrity, including dye permeability and/or phospholipid distribution. Key findings for this set of compounds include the following: (1) significant discrepancies in top concentration selection were found when cytotoxicity measurements were based on different methods, with the Flow-NBR approach tending to be the most sensitive, (2) both microscopy- and flow cytometry-based scoring methods detected concentration-dependent micronucleus formation for the three genotoxic agents studied, with good agreement between the reference laboratory and the collaborating laboratories, and (3) whereas flow cytometric analyses showed no significant increases for the non-genotoxicants when top concentration selection was based on Flow-NBR, significantly elevated micronucleus frequencies were observed for concentrations that were chosen based on less-sensitive cytotoxicity assays. Collectively, these results indicate that rapid assessment of genotoxicity can be accomplished with a relatively simple flow cytometric technique, and that the scoring system is transferable across laboratories. Furthermore, a concurrent assessment of cytotoxicity, Flow-NBR, may help reduce the occurrence of irrelevant positive results, as it may represent a more appropriate means for choosing top concentration levels. Finally, the data presented herein reinforce concerns about the manner in which cytotoxicity limits are described in guidance documents, since these recommendations tend to cite fixed cut-off values without reference to methodology.  相似文献   

4.
The mouse bone marrow micronucleus assay is anin vivo test commonly used in the pharmaceutical industry to evaluate the genotoxic potential of new compounds. The test detects agent-induced chromosomal damage or damage of the mitotic spindle apparatus. In this paper the state-of-the-art in automated rodent micronucleus evaluation using computerized image analyis in combination with high-quality slides obtained by the cellulose column fractionation technique is reviewed. The latter allows the effective removal of nucleated cells from rodent bone marrow. It has been found that automatic micronucleus scoring with the Leitz MIAC image analyzer is substantially faster than labor-intensive manual analysis. Automatic scoring can be performed overnight for up to 16 slides. We have been successfully using automatic micronucleus analysis for the testing of new pharmaceutical drugs for more than 3 years.Abbreviations MNE NCE containing micronuclei - MPE PCE containing micronuclei - NCE normochromatic erythrocyte - PCE polychromatic erythrocyte deceased on 25 May 1994  相似文献   

5.
The micronucleus test is of unquestionable importance, being widely used in studies with several purposes. Standardization of the technique has been proposed by several groups mainly when in vivo assays are performed. In cell cultures the staining method that predominates is the Feulgen's reaction, since it is specific for DNA. In this work, we evaluated the use of two fluorescent stains, SYTOX green® and propidium iodide, in substitution for the Feulgen's reaction. Based on the results we concluded that the fluorescence microscopy allows the reliable detection of micronuclei, presenting the following advantages: the technique is easy and fast to perform, it avoids acid treatments; the fluorescence is long lasting; micronucleus counting becomes easier and more reliable by the use of RNAase treatment; the technique is more sensitive to detect the smallest micronuclei.  相似文献   

6.
The micronucleus test is of unquestionable importance, being widely used in studies with several purposes. Standardization of the technique has been proposed by several groups mainly when in vivo assays are performed. In cell cultures the staining method that predominates is the Feulgen's reaction, since it is specific for DNA. In this work, we evaluated the use of two fluorescent stains, SYTOX green and propidium iodide, in substitution for the Feulgen's reaction. Based on the results we concluded that the fluorescence microscopy allows the reliable detection of micronuclei, presenting the following advantages: the technique is easy and fast to perform, it avoids acid treatments; the fluorescence is long lasting; micronucleus counting becomes easier and more reliable by the use of RNAase treatment; the technique is more sensitive to detect the smallest micronuclei.  相似文献   

7.
A new flow cytometric method is presented that quantifies the frequency of radiation-induced micronuclei in mammalian cell cultures with high precision. After preparing a suspension of main nuclei and micronuclei stained with ethidium bromide and Hoechst 33258, both types of particles are measured simultaneously in a flow cytometer using forward light scatter and three fluorescence emission intensities excited by UV, 488 nm, and by energy transfer from Hoechst 33258 to ethidium bromide. Nonspecific debris overlapping the micronucleus distribution especially in the low fluorescence intensity region was discriminated from micronuclei by calculating ratios of the different fluorescences. The frequencies of radiation-induced micronuclei measured with this new technique agreed well with results obtained by conventional microscopy. The lower limit of the DNA content of micronuclei identified by this technique was found to be about 0.5%-0.75% of the DNA content of G1-phase nuclei. Dose effect curves and the time-dependent induction of micronuclei were measured for two different mouse cell lines.  相似文献   

8.
The γH2AX focus assay, based on phosphorylation of the variant histone protein H2AX, was evaluated as a genotoxicity test in immortalised wild-type mouse embryonic fibroblasts (MEFs) treated for 4 h with a panel of reference compounds routinely used in genotoxicity testing. The topoisomerase II poison etoposide (0.006–60 μg/ml), the alkylating agent methyl methanesulfonate (1.3–65 μg/ml) and the direct DNA-damaging agent bleomycin (0.1–10 μg/ml) all produced a positive concentration–response relationship. The non-genotoxic compounds ampicillin (0.035–3500 μg/ml) and sodium chloride (0.058–580 μg/ml) showed no such response with increased concentrations. The H2AX phosphorylation results were compared with the outcome of two standard in vitro genotoxicity tests, namely the micronucleus and comet assays. Compounds that produced measurable DNA damage in the focus assay generated micronuclei at comparable concentrations. In this study, the focus assay identified genotoxic agents with the same specificity as the comet assay.These results were substantiated when H2AX phosphorylation was analysed using flow cytometry in the murine cell line L5178Y, growing in suspension. The data were in concordance with the manual scoring focus assay. To further this investigation, the γH2AX flow cytometry was compared to the in vitro micronucleus flow cytometry and mouse lymphoma assay using the same cell population after MMS treatment. The median γH2AX value increased significantly above the control at all four MMS concentrations tested. The percentage of micronucleus events in the in vitro micronucleus flow test and the mutation frequency in the mouse lymphoma assay were also significantly increased at each MMS concentration. The current data indicate that H2AX phosphorylation could be used as a biomarker of genotoxicity, which could predict the outcome of in vitro mammalian cell genotoxicity assays.  相似文献   

9.
10.
Peripheral human blood from 23 healthy donors aged between 23 and 95 years was exposed to continuous wave (CW) or 50 Hz amplitude modulated (AM) microwave radiation and was cultured for 72 h. Other exposure parameters were: frequency 9 GHz, specific absorption rate (SAR) 90 mW/g, exposure duration 10 min. The possible genotoxic effect was evaluated by means of cytokinesis-block micronucleus method. A significant (p < 0.05) increase in micronuclei was found following AM microwave exposure.  相似文献   

11.
Criteria for scoring micronuclei and nucleoplasmic bridges in binucleated cells in the cytokinesis-block micronucleus assay for isolated human lymphocyte cultures are described in detail. Morphological characteristics of mononucleated cells, binucleated cells, and multinucleated cells as well as necrotic and apoptotic cells and nuclear buds are also described. These criteria are illustrated by a series of schematic diagrams as well as a comprehensive set of colour photographs that are of practical assistance during the scoring of slides. These scoring criteria, diagrams and photographs have been used in a HUman MicronNucleus (HUMN) project inter-laboratory slide-scoring exercise to evaluate the extent of variability that can be attributable to individual scorers and individual laboratories when measuring the frequency of micronuclei and nucleoplasmic bridges in binucleated cells as well as the nuclear division index. The results of the latter study are described in an accompanying paper. It is expected that these scoring criteria will assist in the development of a procedure for calibrating scorers and laboratories so that results from different laboratories for the cytokinesis-block micronucleus assay may be more comparable in the future.  相似文献   

12.
We have evaluated the performance of the prototype In Vitro MicroFlow Kit (Litron Laboratories), which offers a flow cytometric method for scoring micronuclei (MN). This method uses sequential staining to differentiate MN from chromatin fragments derived from apoptotic or necrotic cells. Data were generated using the genotoxins methylmethane sulphonate (MMS), dimethylbenzanthracene (DMBA) and vinblastine, and the non-genotoxins dexamethasone and staurosporine, which are known to induce apoptosis in vitro. The results obtained with these agents were compared with conventional microscopy. For short-duration exposures (3-4h) both manual and flow methodologies demonstrated good concordance, with concentration-related increases in the percentage of MN for MMS, DMBA and vinblastine. Statistically significant increases were observed at > or = 20 and 40 microg/mL, for manual and flow analysis, respectively, for MMS; at 0.5 and 0.75 microg/mL for DMBA; and at 0.035 and 0.04 microg/mL, respectively, for vinblastine. Dexamethasone showed clear negative responses by manual and flow cytometric analysis, with comparable results for both methodologies (all <1.7-fold compared with concurrent vehicle controls). Data for staurosporine, however, were less consistent showing significantly higher flow cytometric MN frequencies compared with those seen after manual analysis. Continuous (24 h) treatments were also conducted with MMS, vinblastine, dexamethasone and staurosporine. There was good concordance between the methodologies for MMS, staurosporine and vinblastine. However, dexamethasone generated discordant results, i.e. microscopic analysis was clearly negative at all doses tested, whereas flow cytometry produced significant increases in MN frequency (up to 8.1-fold at 100 microg/mL compared with the concurrent vehicle control). The inconsistencies observed between flow cytometry and standard microscopy, and the differences in assay sensitivity, particularly for apoptosis-inducing compounds, suggest that the prototype In Vitro MicroFlow Kit requires further refinement. Studies to investigate new parameters to address these issues are now under way and will be reported separately.  相似文献   

13.
We have evaluated the performance of the prototype In Vitro MicroFlow® Kit (Litron Laboratories), which offers a flow cytometric method for scoring micronuclei (MN). This method uses sequential staining to differentiate MN from chromatin fragments derived from apoptotic or necrotic cells. Data were generated using the genotoxins methylmethane sulphonate (MMS), dimethylbenzanthracene (DMBA) and vinblastine, and the non-genotoxins dexamethasone and staurosporine, which are known to induce apoptosis in vitro. The results obtained with these agents were compared with conventional microscopy.For short-duration exposures (3–4 h) both manual and flow methodologies demonstrated good concordance, with concentration-related increases in the percentage of MN for MMS, DMBA and vinblastine. Statistically significant increases were observed at ≥20 and 40 μg/mL, for manual and flow analysis, respectively, for MMS; at 0.5 and 0.75 μg/mL for DMBA; and at 0.035 and 0.04 μg/mL, respectively, for vinblastine. Dexamethasone showed clear negative responses by manual and flow cytometric analysis, with comparable results for both methodologies (all <1.7-fold compared with concurrent vehicle controls). Data for staurosporine, however, were less consistent showing significantly higher flow cytometric MN frequencies compared with those seen after manual analysis.Continuous (24 h) treatments were also conducted with MMS, vinblastine, dexamethasone and staurosporine. There was good concordance between the methodologies for MMS, staurosporine and vinblastine. However, dexamethasone generated discordant results, i.e. microscopic analysis was clearly negative at all doses tested, whereas flow cytometry produced significant increases in MN frequency (up to 8.1-fold at 100 μg/mL compared with the concurrent vehicle control).The inconsistencies observed between flow cytometry and standard microscopy, and the differences in assay sensitivity, particularly for apoptosis-inducing compounds, suggest that the prototype In Vitro MicroFlow® Kit requires further refinement. Studies to investigate new parameters to address these issues are now under way and will be reported separately.  相似文献   

14.
S. Madle  J. Nowak  G. Obe 《Human genetics》1976,34(2):143-149
Summary Cells containing X-ray induced micronuclei were treated for a few hours before fixation with inhibitors of DNA synthesis (cytosine arabinoside; azathioprine; thymidine; trenimon), of RNA synthesis (actinomycin D; ethidium bromide), and of protein synthesis (puromycin). Only the inhibitors of DNA synthesis lead to a significant suppression of the frequencies of mitoses with micronucleus derived premature chromosome condensation (PCC). We tend to interprete the result as follows: Micronuclei that are in the G1 phase of their cell cycles are accumulated at the G1/S border or in the early S phase of their cell cycles under the influence of the inhibitors of the DNA synthesis. Micronuclei blocked in this way cannot be induced to undergo PCC and seem to disappear from the cells.  相似文献   

15.
Sulfonic acid esters are considered as potentially alkylating agents that may exert genotoxic effects in bacterial and mammalian cell systems. One possible source of human exposure stems from drug synthesis when the salt-forming agents methanesulfonic acid, benzenesulfonic acid or p-toluenesulfonic acid are used together with alcoholic solvents such as methanol, ethanol and propanol. In this study computer-assisted structural considerations and in vitro approaches (Ames mutagenicity test using Salmonella typhimurium strains TA98 and TA100, and the micronucleus test using L5178Y mouse lymphoma cells) were used to assess the genotoxic properties of 19 sulfonic esters. While all esters may be principally active as genotoxicants based on the presence of the sulfonate moiety, the statistical correlative multiple computer automated structure evaluation (MCASE) system (MC4PC version 1.0) using the Ames mutagenicity A2I module (version 1.54), rank-ordered the activity of the benzenesulfonic acid esters in the Ames test negligible due to an inactivating modulator and a deactivating fragment, whereas the methane- and toluenesulfonic acid esters were predicted to be positive in this test. In the Ames test, with the exception of the p-toluenesulfonic acid ethyl and iso-butyl esters, all compounds came out positive in Salmonella strain TA100. Methanesulfonic iso-propyl, sec-butyl and benzenesulfonic acid iso-propyl ester also showed mutagenic potential in strain TA98. In general, differences between results seen in Ames tests performed with or without metabolic activation were rather small. In L5178Y mouse lymphoma cells, benzenesulfonic acid n- and iso-butyl ester and p-toluenesulfonic acid iso-butyl ester did not increase the number of cells containing micronuclei. The other esters were positive in this micronucleus test; however, methanesulfonic acid iso-butyl ester was found to be only weakly positive at excessively cytotoxic concentrations. These compounds were generally found to be more potent with regard to micronucleus induction when tested without metabolic activation (20 h treatment). In conclusion, the iso-propyl esters of the three sulfonic acids under study were found to be the strongest mutagens, either when tested in the Ames test or the micronucleus assay, whereas p-toluenesulfonic acid iso-butyl ester was the only compound shown to be devoid of a genotoxic potential in both tests.  相似文献   

16.
It was previously found that -tyrosine oxidation product(s) are cytotoxic, genotoxic and increase the sister chromatid exchange (SCE) levels in human melanoma cells. In this work, the micronucleus assay has been performed on human melanotic and amelanotic melanoma cell lines (Carl-1 MEL and AMEL) in the presence of 1.0, 0.5 and 0.1 mM -tyrosine concentrations to investigate if melanin synthesis intermediate(s) increase micronuclei production. -Tyrosine oxidation product(s) increased the frequency of micronuclei in melanoma cells; 0.1 mM phenylthiourea (PTU), an inhibitor of -tyrosine oxidation by tyrosinase, lowered the micronucleus production to the control levels. The culture of melanoma cells with high -tyrosine in the culture medium resulted in a positive response to an ELISA-based apoptotic test. For comparison the effect of -tyrosine on micronuclei production in human amelanotic melanoma cells was also investigated; the micronucleus production in the presence of 1 mM -tyrosine in the culture medium was lower than that found with melanotic melanoma cells of the same cell line. The data suggest that melanin synthesis intermediates arising from -tyrosine oxidation may cause micronuclei production in Carl-1 human melanoma cells; the addition of PTU in the presence of -tyrosine decreased the frequency of micronuclei to about the control values thus the inhibition of melanogenesis may have some clinical implication in melanotic melanoma.  相似文献   

17.
The cytokinesis block micronucleus method, a very sensitive cytogenetic assay, was used to ascertain the possible genotoxic effects of extremely low frequency pulsed magnetic fields in phytohemagglutinin-stimulated human lymphocytes cultures from 16 healthy donors. Four conditions were studied: i) lymphocytes not exposed to the field (control cultures); ii) lymphocytes exposed to the field; iii) lymphocytes treated with mitomycin-C and not exposed to the field; iv) lymphocytes treated with mitomycin-C and exposed to the field. Mitomycin-C-treated cultures were used as control for the micronucleus method, because it is known that mitomycin-C is a potent genotoxic agent, capable of inducing micronuclei. The frequency of micronuclei in field-exposed cultures was similar to the spontaneous frequency observed in control unexposed-cultures. Moreover, the exposure to pulsed magnetic fields did not affect the frequency of micronuclei induced by mitomycin-C, suggesting that, in the experimental conditions used, this kind of field neither affected the integrity of chromosomes nor interfered with the genotoxic activity of mitomycin-C.  相似文献   

18.
It was previously found that L-tyrosine oxidation product(s) are cytotoxic, genotoxic and increase the sister chromatid exchange (SCE) levels in human melanoma cells. In this work, the micronucleus assay has been performed on human melanotic and amelanotic melanoma cell lines (Carl-1 MEL and AMEL) in the presence of 1.0, 0.5 and 0.1 mM L-tyrosine concentrations to investigate if melanin synthesis intermediate(s) increase micronuclei production. L-Tyrosine oxidation product(s) increased the frequency of micronuclei in melanoma cells; 0.1 mM phenylthiourea (PTU), an inhibitor of L-tyrosine oxidation by tyrosinase, lowered the micronucleus production to the control levels. The culture of melanoma cells with high L-tyrosine in the culture medium resulted in a positive response to an ELISA-based apoptotic test. For comparison the effect of L-tyrosine on micronuclei production in human amelanotic melanoma cells was also investigated; the micronucleus production in the presence of 1 mM L-tyrosine in the culture medium was lower than that found with melanotic melanoma cells of the same cell line. The data suggest that melanin synthesis intermediates arising from L-tyrosine oxidation may cause micronuclei production in Carl-1 human melanoma cells; the addition of PTU in the presence of L-tyrosine decreased the frequency of micronuclei to about the control values thus the inhibition of melanogenesis may have some clinical implication in melanotic melanoma.  相似文献   

19.
Chlorination is widely used method in the disinfection of drinking and utility water worldwide. In this study, cytotoxic and genotoxic effects of sodium hypochlorite were investigated by the cytokinesis-block micronucleus assay and chromosomal aberration analysis on human peripheral lymphocytes in vitro. A significant increase in chromosomal aberration frequency was observed in all treatments of NaOCl (0.030, 0.065, 0.100, 0.25, 0.5, 1, 2, 4 μg/mL) at 24 and 48 h compared with the negative control and mitomycin C (MMC, 0.3 μg/mL), which was used as a positive control. NaOCl significantly increased the frequency of micronuclei in a dose dependent manner. The results showed that there was a significant correlation between NaOCl concentration and chromosomal aberration, micronuclei frequency, necrotic cells, apoptotic cells and binucleated cells.  相似文献   

20.
Aneuploidy plays a significant role in adverse human health conditions including birth defects, pregnancy wastage, and cancer. Currently, there is no screening method sufficiently validated that can be used routinely to identify aneugenic agents in vitro because most conventional test systems rely on the labor-intensive microscopic assessment of the aneuploid cell population. Our laboratory has recently developed a flow cytometry-based procedure for assessing numerical chromosomal aberrations in mitotic populations of lymphocytes on the basis of DNA content. Studies were conducted in 24 h treated human lymphocyte cultures to determine the sensitivity of this flow cytometry-based procedure to detect aneugenic agents. A comparison between the microscopic and the flow cytometry-based procedures for scoring polyploidy shows a strong agreement exists between the two methods. Treatments with two known aneugenic agents, griseofulvin, and paclitaxel (taxol), resulted in a dose-related increase in the mitotic index, aneuploidy, and polyploidy. In contrast, results from the treatments with two known clastogenic agents, mitomycin-C, and etoposide, show a dose-related decrease in the mitotic index with a slight increase in the frequency of hypodiploidy at concentrations that produce severe chromosomal breakage. There were no increases in hyperdiploidy and polyploidy observed. In conclusion, the reproducibility of the results obtained in this study indicates that this flow cytometry-based procedure for assessing numerical chromosomal effects in mitotic populations on the basis of DNA content is promising for the routine detection and characterization of aneugenic agents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号