1.
In selected patients with atrial fibrillation and severe symptoms, non-pharmacological treatment may be an alternative or supplement to drug therapy. Atrioventricular nodal radiofrequency ablation (requires pacemaker implantation), or atrial pacing for sick sinus syndrome, are established treatment modalities. All other non-pharmacological therapies for atrial fibrillation are still experimental. After the Maze operation, atrial depolarization has to follow one specific path determined by surgical scars in the myocardium. This prevents new episodes of atrial fibrillation, but at a cost of perioperative morbidity and mortality. Catheter-based "Maze-like" radiofrequency ablation is technically difficult, and thrombo-embolic complications may occur. Paroxysmal atrial fibrillation sometimes is initiated by spontaneous depolarizations in a pulmonary vein inlet. Radio frequency ablation against such focal activity has been reported with high therapeutic success, but the results await confirmation from several centres. For ventricular rate control, most electrophysiologists presently prefer ablation to induce a complete atrioventricular conduction block (with pacemaker) rather than trying to modify conduction by incomplete block. Atrial or dual chamber pacing may prevent atrial fibrillation induced by bradycardia. It remains to confirm that biatrial or multisite right atrial pacing prevents atrial fibrillation more efficiently than ordinary right atrial pacing. An atrial defibrillator is able to diagnose and convert atrial fibrillation. The equipment is expensive, and therapy without sedation may be unpleasant beyond tolerability.  相似文献   

2.
A 90-year-old woman received a dual chamber pacemaker (PM) for a sick sinus syndrome. The PM was programmed with SafeR AAI-DD pacing mode at 60 bpm. During a standard follow up, some memorized electrograms (EGMs) were found in SafeR diagnostics, with atrial pacing (Ap) not followed by any ventricular sensing/pacing event, due to simultaneous junctional activity falling into ventricular blanking period during Ap and, for this reason, unsensed by the PM. Blanking periods can affect PM functioning if not revealed and adjusted.  相似文献   

3.
Left ventricular (LV) dysfunction can occur due to chronic right ventricular apical pacing. Upgrading of the pacemaker to biventricular pacing is an option to reverse LV dysfunction but reprogramming of the atrioventricular (AV) timing can also be favourable. In this case report we describe the effect of AV-time reprogramming in a patient with LV function deterioration that emerged two years after implantation of a dual chamber system for sick sinus syndrome. Echocardiographc studies demonstrated a tremendous improvement in LV function during two years follow-up whereas the percentage of right ventricular pacing diminished dramatically. Careful analysis of the cause of LV deterioration can avoid unnecessary upgrading to biventricular pacing. (Neth Heart J 2010;18:604–5.)  相似文献   

4.
Disturbances of rhythm and conduction in patients undergoing surgery for transposition of the great arteries have been widely reported. Some of these patients require implantation of a permanent pacemaker, especially those in whom symptomatic sick sinus syndrome is diagnosed. We present the case of a 29-year-old male corrected with a Mustard procedure, who received a pacemaker for progressive atrioventricular conduction disturbances and sinus node dysfunction, and we review the possible complications associated with transvenous pacemaker implantation in these patients. (Neth Heart J 2007;15:387-389.)  相似文献   

5.
We present a case of a single chamber atrial pacemaker implanted for sinus node dysfunction and treatment of macroreentrant atrial tachycardias with atrial antitachycardia pacing. The patient presented with sustained atrial tachycardia above the detection rate, however, the device was unable to detect the tachycardia and did not deliver the programmed therapy. We discuss the nuances of the atrial tachyarrhythmia detection algorithms, and the programming strategies to maximize detection of atrial arrhythmias in a single chamber atrial pacemaker.  相似文献   

6.
目的:分析永久心脏起搏器植入术出现并发症的原因、相关因素及预防措施。方法:回顾分析2009年1月~2011年12月321例永久心脏起搏器植入患者的临床资料。其中男172例,女149例,平均年龄56.7±18.4岁。其中病态窦房结综合征136例,三度房室阻滞97例;二度II型房室阻滞76例,起搏器更换35例。结果:321例植入永久心脏起搏器患者中发生并发症17例,发生率为5.29%。其中与囊袋相关并发症4例,电极导线相关并发症4例、起搏器相关并发症2例,术中操作所致并发症3例。结论:深化对起搏器常见临床并发症的了解,进一步完善术前准备,重视术中规范操作并加强术后管理,可降低其并发症的发生率。  相似文献   

7.
OBJECTIVE--To compare present pacing practice with the recommendations recently published by the British Pacing and Electrophysiology Group and to assess the increase in annual budget required to implement these recommendations in a regional cardiothoracic unit. DESIGN--Retrospective analysis of pacemaker implantation for 1991 with calculation of the costs required to implement the group''s recommendations based on average 1991 costs of the types of pacing generators and electrode leads used. SETTING--Regional cardiothoracic unit for South West Thames Health Authority. PATIENTS--433 consecutive patients receiving permanent pacemaker generators: 76 (18%) with sinus node disease; 270 (62%) with atrioventricular block; 25 (6%) with both sinus node disease and atrioventricular block; 59 (14%) with chronic atrial fibrillation and atrioventricular block; and 3 (1%) with carotid sinus or malignant vasovagal syndromes. RESULTS--Only 102 (24%) patients received pacemaker generators recommended by the British Pacing and Electrophysiology Group; however, 355 (82%) patients were older than 65 years, and 264 (61%) were aged 75 or over. The cost of hardware for pacing was 462,885 pounds. Using generators as recommended would have cost 810,525 pounds for "optimal" systems (an increase of 75%) and 710,750 pounds for "alternative" systems (an increase of 54%). These increases would have been considerably reduced by limiting the use of sophisticated pacing to younger patients (aged under 75). Further savings could be made by using the least expensive pacing models available. CONCLUSIONS--Implementing these recommendations should reduce morbidity related to bradyarrhythmia but will lead to major increases in pacing costs. Age and patients'' expected activity may be used to select simple pacing systems and thus to contain cost. More research is needed to determine which patient groups will benefit most from complex pacing systems.  相似文献   

8.
Usually an electrocardiogram after right ventricular (RV) pacing should yield left bundle branch block (LBBB) pattern. However, the presence of right bundle branch block (RBBB) pattern after pacemaker implantation should alert the physician to a malposition of lead. We report a case of 18-year-old female who underwent dual chamber pacemaker implantation and had RBBB pattern post implantation. Detailed evaluation revealed an uncomplicated right ventricular outflow tract pacing. The possible causes of this abnormal pattern after an uncomplicated RV pacing are also reviewed.  相似文献   

9.
A 62-year-old patient presented with dizzy spells after her dual chamber pacemaker (Medtronic Enrhythm P1501DR), implanted for complete AV block, had been reprogrammed to deliver antitachycardia therapy (ATP) for paroxysmal atrial tachycardia. Her symptoms were caused by inhibition of ventricular backup pacing during ATP, leading to ventricular asystoles. Inhibition was the result of premature ventricular beats occurring prior to ATP: when ventricular backup pacing is left in the default setting, this pacemaker withholds backup pacing if any of the four preceding events is a sensed event. This case illustrates the possibly hazardous effects of default pacemaker settings, especially in pacemaker-dependent patients. (Neth Heart J 2010;18:323-6.)  相似文献   

10.
After implantation of a permanent pacemaker, patients may experience severe symptoms of dyspnea, palpitations, malaise, and syncope resulting from pacemaker syndrome. Although pacemaker syndrome is most often ascribed to the loss of atrioventricular (A-V) synchrony, more recent data may also implicate left ventricular dysynchrony caused by right ventricular pacing. Previous studies have not shown reductions in mortality or stroke with rate-modulated dual-chamber (DDDR) pacing as compared to ventricular-based (VVI) pacing. The benefits in A-V sequential pacing with the DDDR mode are likely mitigated by the interventricular (V-V) dysynchrony imposed by the high percentage of ventricular pacing commonly seen in the DDDR mode. Programming DDDR pacemakers to encourage intrinsic A-V conduction and reduce right ventricular pacing will likely decrease heart failure and pacemaker syndrome. Studies are currently ongoing to address these questions.  相似文献   

11.
A 58 year old male, known case of type 2 diabetes and hypertension, had undergone implantation of a dual chamber pacemaker(DDDR) in 2007 for complaints of recurrent syncope and trifascicular block with a normal ejection fraction andnormal coronaries. His post implantation parameters were normal at that time.He now presented to our pacemaker clinic where his ECG done showed two types o fpaced complexes. The first few complexes were consistent with atrial sensed right ventricular apical pacing with left superior axis. Later complexes showed loss of atrial sensing with pacing from right ventricular outflow tract(inferior axis) with subtle oscillation in it''s axis. On application of magnet, two pacemaker spikes were visible withinterspike interval of 120 ms and paced complexes with inferior axis starting from the first spike suggesting that the atrial lead was responsible for RVOT depolarization. On interrogation of the pacemaker, atrial EGM showed sensed activity from atrium followed by large sensed ventricular complex. Fluoroscopy confirmed that the atrial lead was dislodged and was intermittently prolapsing into the RVOT. Since the patient was asymptomatic, he refused any intervention and subsequentlyhis atrial lead was switched off by telemetry. The above case signifies that asymptomatic lead dislodgement is no talways manifested as loss of capture and even subtle variation of the axis o fthe paced complexes can provide us with a clue that can be confirmed by telemetry of the pacemaker and fluoroscopy.  相似文献   

12.
Adult congenital heart disease patients may undergo numerous fluoroscopically guided procedures including pacemaker implantation during their lifetime. One alternative to traditional pacemaker setup which may improve long-term pacing outcomes is His bundle pacing. Given the altered His-bundle location, and given increased radiation exposure over a lifetime, we used 3-dimensional mapping to locate the His and to minimize fluoroscopy for placement of a His-bundle pacemaker system in a 31-year old patient with atrioventricular canal defect and complete heart block with 100% RV pacing and epicardial lead fracture.MethodsAn Octapolar Livewire catheter (Abbott, Minneapolis, USA) was used for mapping and location of the His bundle from a right femoral venous access on the EnSite Precision system 3-dimensional mapping system (Abbott Medical, Abbott Park, IL). The same map was used to guide 3830 lead placement into the posterior-inferior His-bundle position.ResultsSuccessful placement of a His-bundle pacing system with thresholds of 1Volt@0.4ms for both the atrial and ventricular leads with selective His-bundle pacing noted. Ten-month follow-up demonstrated His-bundle capture at 0.75V@0.4ms with stable impedance, sensing and with 100% right ventricular pacing a projected longevity of 12 years total.ConclusionsSuccessful placement of selective His-bundle pacing can be achieved in an adult patient with atrioventricular canal defect using 3-dimensional mapping.  相似文献   

13.

Background

Good and reliable atrial sensing is a fundamental part of atrioventricular (AV) synchrony in dual chamber pacemakers. Due to the floating nature of atrial sensing electrode in single pass dual chamber pacemakers (VDD) compared with two-lead dual chamber pacemakers (DDD), they are more prone to atrial under-sensing and the resulting loss of AV synchrony. We hypothesized that there is a relation between the chronicity of AV block and the amplitude of intracardiac atrial signal amplitudes (IASA).

Methods

Detailed demographic, electrocardiographic and echocardiographic data were recorded in 34 consecutive patients with congenital and acquired complete heart block (CHB). The intracardiac atrial signal amplitudes (IASA) were recorded at implantation time, 48 hours and 2 months post-implantation and compared between the two groups of patients.

Results

The mean age of the study group was 38.73±12.53 years (congenital: 30.08±11.07, acquired: 47.38±6.5). There were no important differences in left atrial or ventricular sizes and in P-wave amplitude in lead II, but the IASA was significantly higher in the congenital group at implantation time (5.21±1.86 vs. 3.38±0.84 mV, P<0.001) and during the follow-up.

Conclusion

The intracardiac atrial signal amplitudes were higher in congenital CHB compared with the acquired CHB. Chronicity (and may be the congenital type) of CHB may be an affecting factor in case selection for VDD pacemaker implantation.  相似文献   

14.
Upper venous system anatomic variations may cause difficulties during cardiac pacemaker implantation. Persistent left superior vena cava (PLSVC) and absent right superior vena cava could be an arrhythmogenic source of atrial arrhythmias and cardiac conduction disease. We represent dual-chamber pacemaker implantation in a patient with a very rare upper venous system anomaly, paroxysmal atrial fibrillation, sick sinus syndrome, that cause unusual fluoroscopic image.  相似文献   

15.

Objectives

Left atrium (LA) plays an important role in left ventricular filling. It is well known that right ventricular apical pacing has unfavorable effects on ventricular systolic and diastolic performance. The aim of this study is to evaluate the LA mechanical functions with 2D echocardiography in patients with a permanent pacemaker after short time ventricular pacing.

Design

Echocardiographic examination was performed in 38 patients (mean age 63.0± 10.9, 18 female) with dual chamber pacemakers or defibrillators (< 20% ventricular pacing within previous 6 months, all of them on sinus rhythm) before and after 4 hours > 90% ventricular pacing at 70 beats per minute in DDD mode with an optimal AV interval. Left atrial volumes (LAV) including at the time of mitral valve opening (Vmax), at closure (Vmin), and at the onset of atrial systole (Volp) were measured. The passive emptying, conduit, active emptying and total emptying volume, stroke volumes were also calculated.

Results

No significant differences were noted at baseline and after pacing for absolute Vmax, Volp, passive emptying, conduit, active emptying, total emptying volumes as well as the volumes indexed to body surface area (p >0.05).

Conclusions

Short - time RV pacing seems to have no acute effects on left atrial mechanical functions.  相似文献   

16.
Cardiac resynchronization therapy is not commonly used in the early postoperative period in patients undergoing cardiac surgery who have left ventricular (LV) dysfunction and a history of heart failure. We performed a prospective randomized clinical trial to compare atrial synchronous right ventricular (DDD RV) and biventricular (DDD BIV) pacing within 72 hours after cardiac surgery in patients with an EF ≤35 %, a QRS interval longer than 120 msec and who had LV dyssynchrony detected by real-time three-dimensional echocardiography (RT3DE). Epicardial pacing was provided by a modified Medtronic INSYNC III pacemaker. An LV epicardial pacing lead was implanted on the latest activated segment of the LV based on RT3DE. The study included 18 patients with ischemic heart disease, with or without valvular heart disease (14 men, 4 women, average age 71 years). Patients undergoing DDD BIV pacing had a statistically significant greater CO and CI (CO 6.7±1.8 l/min, CI 3.4±0.7 l/min/m(2)) than patients undergoing DDD RV pacing (CO 5.5±1.4 l/min, CI 2.8±0.7 l/min/m(2)), p<0.001. DDD BIV pacing in the early postoperative period after cardiac surgery corrects LV dyssynchrony and has better hemodynamic results than DDD RV pacing.  相似文献   

17.
Congenital diaphragmatic hernia is very rare cause of AV block. We report such a patient with sick sinus node syndrome and previous AAIR pacemaker implantation, in which intermittent AV block was diagnosed by 24-hours ECG monitoring and upgrade of pacing system to DDDR was suggested.  相似文献   

18.
A 63-year-old lady with a high-grade atrioventricular (AV) block and a structurally normal heart underwent permanent pacemaker implantation (dual chamber, Medtronic Ltd) 8 years back. On follow up, she had a recurrence of syncope after 3 years. The device interrogation at that time had revealed ventricular tachycardia (VT) for which she underwent implantable cardioverter defibrillator (ICD, Medtronic Ltd, Egida DR, DF1) upgradation at another center (electrograms not available). Now, she presents with episodes of presyncope after another 5 years. The Echocardiography was unremarkable. The ICD was interrogated & there was a stored ventricular fibrillation (VF) episode. But the electrograms suggested noise over a true VF electrogram noted in both near and far-field. In all probability, the VF was not a true one which might have arisen from some lead noise or from an electromagnetic interference (EMI). Fluoroscopy revealed an evident lead fracture near the superior vena cava (SVC) coil. The stored electrogram (EGM) characteristics also suggested possible lead noise rather than a true VF. She was advised for lead revision. Interestingly, all pacing parameters were normal along with normal impedance despite the evident lead fracture. This happened due to the ICD lead arrangements as there are separate electrodes for the SVC/RV coil and pacing. While the SVC coil was damaged, the pacing electrodes remained unaffected. Since the patient has no episode of true VT/NSVT and the echocardiography was normal, she was managed temporarily by changing the pacemaker to asynchronous (DOO) mode.  相似文献   

19.
Excessive right ventricular apex pacing has significant adverse effects on the cardiac function and hence, it is necessary to clinically optimize pacing parameters and advocate suitable physiological pacing to safeguard the cardiac function after pacemaker implant. Minimizing ventricular pacing is an atrioventricular node priority function, to encourage ventricular self conduction and to reduce unnecessary right ventricular pacing. Minimized ventricular pacing reduces ventricular pacing by encouraging self atrioventricular conduction function and extending the AV interval. This study is a prospective cohort study to evaluate the changes of cardiac function in patients and serum amino-terminal natriuretic peptide (NT-proBNP) before and after pacing, and the risk of atrial fibrillation with different CUM% VP. The study has shown that the cardiac function will deteriorate with an increase in pacing rate.  相似文献   

20.
We present the case of a patient with a heart failure episode induced by acute right ventricular pacing. After reversal of beta-blockers because of chronic obstructive pulmonary disease (COPD) exacerbation, the following sinus tachycardia caused a 2:1 atrioventricular block and consequent continuous right ventricular pacing. He was treated with the selective I(f) inhibitor ivabradine, that reduced both ventricular pacing percentage and heart rate without affecting atrioventricular conduction. Ivabradine may be a valuable option in treatment of patients with atrioventricular conduction disturbances.  相似文献   