1.
Spectrotemporal modulation (STM) detection performance was examined for cochlear implant (CI) users. The test involved discriminating between an unmodulated steady noise and a modulated stimulus. The modulated stimulus presents frequency modulation patterns that change in frequency over time. In order to examine STM detection performance for different modulation conditions, two different temporal modulation rates (5 and 10 Hz) and three different spectral modulation densities (0.5, 1.0, and 2.0 cycles/octave) were employed, producing a total 6 different STM stimulus conditions. In order to explore how electric hearing constrains STM sensitivity for CI users differently from acoustic hearing, normal-hearing (NH) and hearing-impaired (HI) listeners were also tested on the same tasks. STM detection performance was best in NH subjects, followed by HI subjects. On average, CI subjects showed poorest performance, but some CI subjects showed high levels of STM detection performance that was comparable to acoustic hearing. Significant correlations were found between STM detection performance and speech identification performance in quiet and in noise. In order to understand the relative contribution of spectral and temporal modulation cues to speech perception abilities for CI users, spectral and temporal modulation detection was performed separately and related to STM detection and speech perception performance. The results suggest that that slow spectral modulation rather than slow temporal modulation may be important for determining speech perception capabilities for CI users. Lastly, test–retest reliability for STM detection was good with no learning. The present study demonstrates that STM detection may be a useful tool to evaluate the ability of CI sound processing strategies to deliver clinically pertinent acoustic modulation information.  相似文献   

2.
For the perception of timbre of a musical instrument, the attack time is known to hold crucial information. The first 50 to 150 ms of sound onset reflect the excitation mechanism, which generates the sound. Since auditory processing and music perception in particular are known to be hampered in cochlear implant (CI) users, we conducted an electroencephalography (EEG) study with an oddball paradigm to evaluate the processing of small differences in musical sound onset. The first 60 ms of a cornet sound were manipulated in order to examine whether these differences are detected by CI users and normal-hearing controls (NH controls), as revealed by auditory evoked potentials (AEPs). Our analysis focused on the N1 as an exogenous component known to reflect physical stimuli properties as well as on the P2 and the Mismatch Negativity (MMN). Our results revealed different N1 latencies as well as P2 amplitudes and latencies for the onset manipulations in both groups. An MMN could be elicited only in the NH control group. Together with additional findings that suggest an impact of musical training on CI users’ AEPs, our findings support the view that impaired timbre perception in CI users is at partly due to altered sound onset feature detection.  相似文献   

3.

Objective

To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users.

Methods

Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280×720, 640×480, 320×240, 160×120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0–500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed.

Results

Higher frame rate (>7 fps), higher camera resolution (>640×480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032).

Conclusion

Webcameras have the potential to improve telecommunication of hearing-impaired individuals.  相似文献   

4.

Objective

To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients.

Method

This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant centre. Twelve experienced users of an Advanced Bionics HiRes90K or CII implant with a Harmony speech processor were enrolled. The cochlear implant processor of each subject was connected to one of two bilaterally placed state-of-the-art hearing aids (Phonak Ambra) providing three alternative directional processing options: an omnidirectional setting, an adaptive monaural beamformer, and a binaural beamformer. A further noise reduction algorithm (ClearVoice) was applied to the signal on the cochlear implant processor itself. The speech signal was presented from 0° and speech shaped noise presented from loudspeakers placed at ±70°, ±135° and 180°. The Oldenburg sentence test was used to determine the signal-to-noise ratio at which subjects scored 50% correct.

Results

Both the adaptive and binaural beamformer were significantly better than the omnidirectional condition (5.3 dB±1.2 dB and 7.1 dB±1.6 dB (p<0.001) respectively). The best score was achieved with the binaural beamformer in combination with the ClearVoice noise reduction algorithm, with a significant improvement in SRT of 7.9 dB±2.4 dB (p<0.001) over the omnidirectional alone condition.

Conclusions

The study showed that the binaural beamformer implemented in the Phonak Ambra hearing aid could be used in conjunction with a Harmony speech processor to produce substantial average improvements in SRT of 7.1 dB. The monaural, adaptive beamformer provided an averaged SRT improvement of 5.3 dB.  相似文献   

5.
Evidence of visual-auditory cross-modal plasticity in deaf individuals has been widely reported. Superior visual abilities of deaf individuals have been shown to result in enhanced reactivity to visual events and/or enhanced peripheral spatial attention. The goal of this study was to investigate the association between visual-auditory cross-modal plasticity and speech perception in post-lingually deafened, adult cochlear implant (CI) users. Post-lingually deafened adults with CIs (N = 14) and a group of normal hearing, adult controls (N = 12) participated in this study. The CI participants were divided into a good performer group (good CI, N = 7) and a poor performer group (poor CI, N = 7) based on word recognition scores. Visual evoked potentials (VEP) were recorded from the temporal and occipital cortex to assess reactivity. Visual field (VF) testing was used to assess spatial attention and Goldmann perimetry measures were analyzed to identify differences across groups in the VF. The association of the amplitude of the P1 VEP response over the right temporal or occipital cortex among three groups (control, good CI, poor CI) was analyzed. In addition, the association between VF by different stimuli and word perception score was evaluated. The P1 VEP amplitude recorded from the right temporal cortex was larger in the group of poorly performing CI users than the group of good performers. The P1 amplitude recorded from electrodes near the occipital cortex was smaller for the poor performing group. P1 VEP amplitude in right temporal lobe was negatively correlated with speech perception outcomes for the CI participants (r = -0.736, P = 0.003). However, P1 VEP amplitude measures recorded from near the occipital cortex had a positive correlation with speech perception outcome in the CI participants (r = 0.775, P = 0.001). In VF analysis, CI users showed narrowed central VF (VF to low intensity stimuli). However, their far peripheral VF (VF to high intensity stimuli) was not different from the controls. In addition, the extent of their central VF was positively correlated with speech perception outcome (r = 0.669, P = 0.009). Persistent visual activation in right temporal cortex even after CI causes negative effect on outcome in post-lingual deaf adults. We interpret these results to suggest that insufficient intra-modal (visual) compensation by the occipital cortex may cause negative effects on outcome. Based on our results, it appears that a narrowed central VF could help identify CI users with poor outcomes with their device.  相似文献   

6.
The objective was to determine if one of the neural temporal features, neural adaptation, can account for the across-subject variability in behavioral measures of temporal processing and speech perception performance in cochlear implant (CI) recipients. Neural adaptation is the phenomenon in which neural responses are the strongest at the beginning of the stimulus and decline following stimulus repetition (e.g., stimulus trains). It is unclear how this temporal property of neural responses relates to psychophysical measures of temporal processing (e.g., gap detection) or speech perception. The adaptation of the electrical compound action potential (ECAP) was obtained using 1000 pulses per second (pps) biphasic pulse trains presented directly to the electrode. The adaptation of the late auditory evoked potential (LAEP) was obtained using a sequence of 1-kHz tone bursts presented acoustically, through the cochlear implant. Behavioral temporal processing was measured using the Random Gap Detection Test at the most comfortable listening level. Consonant nucleus consonant (CNC) word and AzBio sentences were also tested. The results showed that both ECAP and LAEP display adaptive patterns, with a substantial across-subject variability in the amount of adaptation. No correlations between the amount of neural adaptation and gap detection thresholds (GDTs) or speech perception scores were found. The correlations between the degree of neural adaptation and demographic factors showed that CI users having more LAEP adaptation were likely to be those implanted at a younger age than CI users with less LAEP adaptation. The results suggested that neural adaptation, at least this feature alone, cannot account for the across-subject variability in temporal processing ability in the CI users. However, the finding that the LAEP adaptive pattern was less prominent in the CI group compared to the normal hearing group may suggest the important role of normal adaptation pattern at the cortical level in speech perception.  相似文献   

7.

Rationale

Previous cochlear implant (CI) studies have shown that single-channel amplitude modulation frequency discrimination (AMFD) can be improved when coherent modulation is delivered to additional channels. It is unclear whether the multi-channel advantage is due to increased loudness, multiple envelope representations, or to component channels with better temporal processing. Measuring envelope interference may shed light on how modulated channels can be combined.

Methods

In this study, multi-channel AMFD was measured in CI subjects using a 3-alternative forced-choice, non-adaptive procedure (“which interval is different?”). For the reference stimulus, the reference AM (100 Hz) was delivered to all 3 channels. For the probe stimulus, the target AM (101, 102, 104, 108, 116, 132, 164, 228, or 256 Hz) was delivered to 1 of 3 channels, and the reference AM (100 Hz) delivered to the other 2 channels. The spacing between electrodes was varied to be wide or narrow to test different degrees of channel interaction.

Results

Results showed that CI subjects were highly sensitive to interactions between the reference and target envelopes. However, performance was non-monotonic as a function of target AM frequency. For the wide spacing, there was significantly less envelope interaction when the target AM was delivered to the basal channel. For the narrow spacing, there was no effect of target AM channel. The present data were also compared to a related previous study in which the target AM was delivered to a single channel or to all 3 channels. AMFD was much better with multiple than with single channels whether the target AM was delivered to 1 of 3 or to all 3 channels. For very small differences between the reference and target AM frequencies (2–4 Hz), there was often greater sensitivity when the target AM was delivered to 1 of 3 channels versus all 3 channels, especially for narrowly spaced electrodes.

Conclusions

Besides the increased loudness, the present results also suggest that multiple envelope representations may contribute to the multi-channel advantage observed in previous AMFD studies. The different patterns of results for the wide and narrow spacing suggest a peripheral contribution to multi-channel temporal processing. Because the effect of target AM frequency was non-monotonic in this study, adaptive procedures may not be suitable to measure AMFD thresholds with interfering envelopes. Envelope interactions among multiple channels may be quite complex, depending on the envelope information presented to each channel and the relative independence of the stimulated channels.  相似文献   

8.
A significant fraction of newly implanted cochlear implant recipients use a hearing aid in their non-implanted ear. SCORE bimodal is a sound processing strategy developed for this configuration, aimed at normalising loudness perception and improving binaural loudness balance. Speech perception performance in quiet and noise and sound localisation ability of six bimodal listeners were measured with and without application of SCORE. Speech perception in quiet was measured either with only acoustic, only electric, or bimodal stimulation, at soft and normal conversational levels. For speech in quiet there was a significant improvement with application of SCORE. Speech perception in noise was measured for either steady-state noise, fluctuating noise, or a competing talker, at conversational levels with bimodal stimulation. For speech in noise there was no significant effect of application of SCORE. Modelling of interaural loudness differences in a long-term-average-speech-spectrum-weighted click train indicated that left-right discrimination of sound sources can improve with application of SCORE. As SCORE was found to leave speech perception unaffected or to improve it, it seems suitable for implementation in clinical devices.  相似文献   

9.
Nucleus cochlear implant systems incorporate a fast-acting front-end automatic gain control (AGC), sometimes called a compression limiter. The objective of the present study was to determine the effect of replacing the front-end compression limiter with a newly proposed envelope profile limiter. A secondary objective was to investigate the effect of AGC speed on cochlear implant speech intelligibility. The envelope profile limiter was located after the filter bank and reduced the gain when the largest of the filter bank envelopes exceeded the compression threshold. The compression threshold was set equal to the saturation level of the loudness growth function (i.e. the envelope level that mapped to the maximum comfortable current level), ensuring that no envelope clipping occurred. To preserve the spectral profile, the same gain was applied to all channels. Experiment 1 compared sentence recognition with the front-end limiter and with the envelope profile limiter, each with two release times (75 and 625 ms). Six implant recipients were tested in quiet and in four-talker babble noise, at a high presentation level of 89 dB SPL. Overall, release time had a larger effect than the AGC type. With both AGC types, speech intelligibility was lower for the 75 ms release time than for the 625 ms release time. With the shorter release time, the envelope profile limiter provided higher group mean scores than the front-end limiter in quiet, but there was no significant difference in noise. Experiment 2 measured sentence recognition in noise as a function of presentation level, from 55 to 89 dB SPL. The envelope profile limiter with 625 ms release time yielded better scores than the front-end limiter with 75 ms release time. A take-home study showed no clear pattern of preferences. It is concluded that the envelope profile limiter is a feasible alternative to a front-end compression limiter.  相似文献   

10.

Objectives

(1) To evaluate the recognition of words, phonemes and lexical tones in audiovisual (AV) and auditory-only (AO) modes in Mandarin-speaking adults with cochlear implants (CIs); (2) to understand the effect of presentation levels on AV speech perception; (3) to learn the effect of hearing experience on AV speech perception.

Methods

Thirteen deaf adults (age = 29.1±13.5 years; 8 male, 5 female) who had used CIs for >6 months and 10 normal-hearing (NH) adults participated in this study. Seven of them were prelingually deaf, and 6 postlingually deaf. The Mandarin Monosyllablic Word Recognition Test was used to assess recognition of words, phonemes and lexical tones in AV and AO conditions at 3 presentation levels: speech detection threshold (SDT), speech recognition threshold (SRT) and 10 dB SL (re:SRT).

Results

The prelingual group had better phoneme recognition in the AV mode than in the AO mode at SDT and SRT (both p = 0.016), and so did the NH group at SDT (p = 0.004). Mode difference was not noted in the postlingual group. None of the groups had significantly different tone recognition in the 2 modes. The prelingual and postlingual groups had significantly better phoneme and tone recognition than the NH one at SDT in the AO mode (p = 0.016 and p = 0.002 for phonemes; p = 0.001 and p<0.001 for tones) but were outperformed by the NH group at 10 dB SL (re:SRT) in both modes (both p<0.001 for phonemes; p<0.001 and p = 0.002 for tones). The recognition scores had a significant correlation with group with age and sex controlled (p<0.001).

Conclusions

Visual input may help prelingually deaf implantees to recognize phonemes but may not augment Mandarin tone recognition. The effect of presentation level seems minimal on CI users'' AV perception. This indicates special considerations in developing audiological assessment protocols and rehabilitation strategies for implantees who speak tonal languages.  相似文献   

11.
One of the putative functions of the medial olivocochlear (MOC) system is to enhance signal detection in noise. The objective of this study was to elucidate the role of the MOC system in speech perception in noise. In normal-hearing human listeners, we examined (1) the association between magnitude of MOC inhibition and speech-in-noise performance, and (2) the association between MOC inhibition and the amount of contralateral acoustic stimulation (CAS)-induced shift in speech-in-noise acuity. MOC reflex measurements in this study considered critical measurement issues overlooked in past work by: recording relatively low-level, linear click-evoked otoacoustic emissions (CEOAEs), adopting 6 dB signal-to-noise ratio (SNR) criteria, and computing normalized CEOAE differences. We found normalized index to be a stable measure of MOC inhibition (mean = 17.21%). MOC inhibition was not related to speech-in-noise performance measured without CAS. However, CAS in a speech-in-noise task caused an SNRSP enhancement (mean = 2.45 dB), and this improvement in speech-in-noise acuity was directly related to their MOC reflex assayed by CEOAEs. Individuals do not necessarily use the available MOC-unmasking characteristic while listening to speech in noise, or do not utilize unmasking to the extent that can be shown by artificial MOC activation. It may be the case that the MOC is not actually used under natural listening conditions and the higher auditory centers recruit MOC-mediated mechanisms only in specific listening conditions–those conditions remain to be investigated.  相似文献   

12.
Nonnative speech poses a challenge to speech perception, especially in challenging listening environments. Audiovisual (AV) cues are known to improve native speech perception in noise. The extent to which AV cues benefit nonnative speech perception in noise, however, is much less well-understood. Here, we examined native American English-speaking and native Korean-speaking listeners'' perception of English sentences produced by a native American English speaker and a native Korean speaker across a range of signal-to-noise ratios (SNRs;−4 to −20 dB) in audio-only and audiovisual conditions. We employed psychometric function analyses to characterize the pattern of AV benefit across SNRs. For native English speech, the largest AV benefit occurred at intermediate SNR (i.e. −12 dB); but for nonnative English speech, the largest AV benefit occurred at a higher SNR (−4 dB). The psychometric function analyses demonstrated that the AV benefit patterns were different between native and nonnative English speech. The nativeness of the listener exerted negligible effects on the AV benefit across SNRs. However, the nonnative listeners'' ability to gain AV benefit in native English speech was related to their proficiency in English. These findings suggest that the native language background of both the speaker and listener clearly modulate the optimal use of AV cues in speech recognition.  相似文献   

13.
14.
It was found that, at a test bandwidth range of 50 Hz, 100% speech intelligibility is retained in naive subjects when, on average, 950 Hz is removed from each subsequent 1000-Hz bandwidth. Thus, speech is 95% redundant with respect to the spectral content. The parameters of the comb filter were chosen from measurements of speech intelligibility in experienced subjects, at which no one subject with normal hearing taking part in the experiment for the first time exhibited 100% intelligibility. Two methods of learning to perceive spectrally deprived speech signals are compared: (1) aurally only and (2) with visual enhancement. In the latter case, speech intelligibility is significantly higher. The possibility of using a spectrally deprived speech signal to develop and assess the efficiency of auditory rehabilitation of implanted patients is discussed.  相似文献   

15.
Detection thresholds for sodium chloride were compared in aqueoussolution, in mixture with a sucrose masker, in mixture witha citric acid masker, and in mixture with both of these maskerstogether. Separately the two maskers raised the threshold ofsodium chloride by three to four times, and together by overnine times, a result consistent with independence (additivity)of the two masking effects. To achieve comparable masking witheither sucrose alone or with citric acid alone would requireincreasing their masking concentrations by about ten times.Hence multiple masking can be a far more efficient means ofconcealing a taste, whether an unpleasant one (e.g. the bittertaste of medicine) or a pleasant one (e.g. a salty or sweetcondiment). Multiple masking has dietary and culinary significance,especially for middle aged and elderly persons concerned aboutsalt intake, because their thresholds for NaCl, whether withor without maskers, are typically two or three times higherthan those of youthful persons. Chem. Senses 22: 529–534,1997.  相似文献   

16.
17.
In the real world, human speech recognition nearly always involves listening in background noise. The impact of such noise on speech signals and on intelligibility performance increases with the separation of the listener from the speaker. The present behavioral experiment provides an overview of the effects of such acoustic disturbances on speech perception in conditions approaching ecologically valid contexts. We analysed the intelligibility loss in spoken word lists with increasing listener-to-speaker distance in a typical low-level natural background noise. The noise was combined with the simple spherical amplitude attenuation due to distance, basically changing the signal-to-noise ratio (SNR). Therefore, our study draws attention to some of the most basic environmental constraints that have pervaded spoken communication throughout human history. We evaluated the ability of native French participants to recognize French monosyllabic words (spoken at 65.3 dB(A), reference at 1 meter) at distances between 11 to 33 meters, which corresponded to the SNRs most revealing of the progressive effect of the selected natural noise (−8.8 dB to −18.4 dB). Our results showed that in such conditions, identity of vowels is mostly preserved, with the striking peculiarity of the absence of confusion in vowels. The results also confirmed the functional role of consonants during lexical identification. The extensive analysis of recognition scores, confusion patterns and associated acoustic cues revealed that sonorant, sibilant and burst properties were the most important parameters influencing phoneme recognition. . Altogether these analyses allowed us to extract a resistance scale from consonant recognition scores. We also identified specific perceptual consonant confusion groups depending of the place in the words (onset vs. coda). Finally our data suggested that listeners may access some acoustic cues of the CV transition, opening interesting perspectives for future studies.  相似文献   

18.
Individual differences in second language (L2) phoneme perception (within the normal population) have been related to speech perception abilities, also observed in the native language, in studies assessing the electrophysiological response mismatch negativity (MMN). Here, we investigate the brain oscillatory dynamics in the theta band, the spectral correlate of the MMN, that underpin success in phoneme learning. Using previous data obtained in an MMN paradigm, the dynamics of cortical oscillations while perceiving native and unknown phonemes and nonlinguistic stimuli were studied in two groups of participants classified as good and poor perceivers (GPs and PPs), according to their L2 phoneme discrimination abilities. The results showed that for GPs, as compared to PPs, processing of a native phoneme change produced a significant increase in theta power. Stimulus time-locked analysis event-related spectral perturbation (ERSP) showed differences for the theta band within the MMN time window (between 70 and 240 ms) for the native deviant phoneme. No other significant difference between the two groups was observed for the other phoneme or nonlinguistic stimuli. The dynamic patterns in the theta-band may reflect early automatic change detection for familiar speech sounds in the brain. The behavioral differences between the two groups may reflect individual variations in activating brain circuits at a perceptual level.  相似文献   

19.

Objectives

(1) To report the speech perception and intelligibility results of Mandarin-speaking patients with large vestibular aqueduct syndrome (LVAS) after cochlear implantation (CI); (2) to compare their performance with a group of CI users without LVAS; (3) to understand the effects of age at implantation and duration of implant use on the CI outcomes. The obtained data may be used to guide decisions about CI candidacy and surgical timing.

Methods

Forty-two patients with LVAS participating in this study were divided into two groups: the early group received CI before 5 years of age and the late group after 5. Open-set speech perception tests (on Mandarin tones, words and sentences) were administered one year after implantation and at the most recent follow-up visit. Categories of auditory perception (CAP) and Speech Intelligibility Rating (SIR) scale scores were also obtained.

Results

The patients with LVAS with more than 5 years of implant use (18 cases) achieved a mean score higher than 80% on the most recent speech perception tests and reached the highest level on the CAP/SIR scales. The early group developed speech perception and intelligibility steadily over time, while the late group had a rapid improvement during the first year after implantation. The two groups, regardless of their age at implantation, reached a similar performance level at the most recent follow-up visit.

Conclusion

High levels of speech performance are reached after 5 years of implant use in patients with LVAS. These patients do not necessarily need to wait until their hearing thresholds are higher than 90 dB HL or PB word score lower than 40% to receive CI. They can do it “earlier” when their speech perception and/or speech intelligibility do not reach the performance level suggested in this study.  相似文献   

20.
For deaf individuals with residual low-frequency acoustic hearing, combined use of a cochlear implant (CI) and hearing aid (HA) typically provides better speech understanding than with either device alone. Because of coarse spectral resolution, CIs do not provide fundamental frequency (F0) information that contributes to understanding of tonal languages such as Mandarin Chinese. The HA can provide good representation of F0 and, depending on the range of aided acoustic hearing, first and second formant (F1 and F2) information. In this study, Mandarin tone, vowel, and consonant recognition in quiet and noise was measured in 12 adult Mandarin-speaking bimodal listeners with the CI-only and with the CI+HA. Tone recognition was significantly better with the CI+HA in noise, but not in quiet. Vowel recognition was significantly better with the CI+HA in quiet, but not in noise. There was no significant difference in consonant recognition between the CI-only and the CI+HA in quiet or in noise. There was a wide range in bimodal benefit, with improvements often greater than 20 percentage points in some tests and conditions. The bimodal benefit was compared to CI subjects’ HA-aided pure-tone average (PTA) thresholds between 250 and 2000 Hz; subjects were divided into two groups: “better” PTA (<50 dB HL) or “poorer” PTA (>50 dB HL). The bimodal benefit differed significantly between groups only for consonant recognition. The bimodal benefit for tone recognition in quiet was significantly correlated with CI experience, suggesting that bimodal CI users learn to better combine low-frequency spectro-temporal information from acoustic hearing with temporal envelope information from electric hearing. Given the small number of subjects in this study (n = 12), further research with Chinese bimodal listeners may provide more information regarding the contribution of acoustic and electric hearing to tonal language perception.  相似文献   