首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 152 毫秒
1.
A pre-patient attenuator (“bowtie filter” or “bowtie”) is used to modulate an incoming x-ray beam as a function of the angle of the x-ray with respect to a patient to balance the photon flux on a detector array. While the current dynamic bowtie design is focused on fan-beam geometry, in this study we propose a methodology for dynamic bowtie design in multi-slice/cone-beam geometry. The proposed 3D dynamic bowtie is an extension of the 2D prior art. The 3D bowtie consists of a highly attenuating bowtie (HB) filled in with heavy liquid and a weakly attenuating bowtie (WB) immersed in the liquid of the HB. The HB targets a balanced flux distribution on a detector array when no object is in the field of view (FOV). The WB compensates for an object in the FOV, and hence is a scaled-down version of the object. The WB is rotated and translated in synchrony with the source rotation and patient translation so that the overall flux balance is maintained on the detector array. First, the mathematical models of different scanning modes are established for an elliptical water phantom. Then, a numerical simulation study is performed to compare the performance of the scanning modes in the cases of the water phantom and a patient cross-section without any bowtie and with a dynamic bowtie. The dynamic bowtie can equalize the numbers of detected photons in the case of the water phantom. In practical cases, the dynamic bowtie can effectively reduce the dynamic range of detected signals inside the FOV. Furthermore, the WB can be individualized using a 3D printing technique as the gold standard. We have extended the dynamic bowtie concept from 2D to 3D by using highly attenuating liquid and moving a scale-reduced negative copy of an object being scanned. Our methodology can be applied to reduce radiation dose and facilitate photon-counting detection.  相似文献   

2.
Liu  Huizhe  Sun  Song  Wu  Lin  Bai  Ping 《Plasmonics (Norwell, Mass.)》2014,9(4):845-850

In this paper, the optical near-field enhancement of graphene bowtie antennas is numerically investigated at terahertz frequencies using boundary element method. The enhanced field intensity at the gap region is a result of the mutual coupling between two triangular elements upon the excitation of graphene plasmons. Firstly, wide plasmon frequency tunability is demonstrated by changing the chemical potential of graphene without the need to alter the antenna geometry. Secondly, by varying the tip angle and radius of curvature of the graphene antennas, the field intensity enhancement at the gap center of the two-element antennas is systematically studied. It is found that graphene bowtie antennas with two round-cornered equilateral triangles have superior performance to other two-element antennas, such as ribbon pair, sharp-cornered bowtie, and disk pair antennas. Last but not least, by applying a moderate chemical potential of 0.4 eV to graphene bowtie antennas, we found that the field intensity enhancement at gap center is about 220 times as much as using gold of comparable sizes. In short, graphene bowtie antennas of rounded corners give rise to considerable near-field enhancement and are promising for a wide range of applications such as molecular sensing at terahertz frequencies.

  相似文献   

3.
Wen  Jing  Wang  Kang  Feng  Hui  Chen  Jiannong  Gao  Xiuming  Hong  Ruijin  Zhang  Dawei 《Plasmonics (Norwell, Mass.)》2017,12(4):1257-1262
Plasmonics - The plasmonic bowtie antenna constantly attracts researchers’ interests recently. In this paper, we design and demonstrate polarization sensitive and ultra-broadband excitations...  相似文献   

4.
Plasmonics - A multiple-mode metal-insulator-metal plasmonic sensor with four coupled bowtie resonators containing two pairs of silver baffles is numerically investigated using the finite element...  相似文献   

5.
Bowtie nanoantenna arrays were fabricated using plasma-assisted nanosphere lithography. The gap of each bowtie nanoantenna was precisely controlled by tuning the oxygen plasma treatment time, and gap distance as small as 30 nm was successfully fabricated. The occurrence of plasmon coupling and the functionality of the bowtie nanoantenna arrays were experimentally and theoretically verified. The plasma treatments help to change the size and gap distance of the nanoparticle arrays to match a specific surface plasmon resonance wavelength. The fabricated nanoantenna array covered a large area (∼1 cm2) and was suitable for large-scale fabrication with simple scale-up of the fabrication instruments, which should lead to novel new applications.  相似文献   

6.
Optimization of the geometry of a metallic bowtie gap at radio frequency is presented. We investigate the geometry of the bowtie gap including gap size, tip width, metal thickness and tip angle at macroscale to find the maximum electric field enhancement across the gap. The results indicate that 90° bowtie with 0.06 λ gap size has the most |E t |2 enhancement. Effects of changing the permittivity and conductivity of the material across the gap are also investigated. NEC-2 simulations show that the numerical calculations agree with the experimental results. Since the design and fabrication of a plasmonic device (nanogap) at nanoscale is challenging, the results of this study can be used to estimate the best design parameters for nanogap structure. Different amounts of enhancement at different frequency ranges are explained by mode volume. The product of the mode volume and |E t |2 enhancement is constant for different gap structures and different frequencies.  相似文献   

7.
We present a novel composite nanostructure consisting of bowtie nanoantennas and asymmetric nanoapertures, which provides a new way of indirectly tuning the resonant wavelengths and manipulating the localized fields. The proposed composite nanostructure cannot only produce a symmetric localized field distribution but also create two asymmetric localized field distributions in optical frequency. The resonant peaks of the composite nanostructure can easily be bidirectionally tuned by indirectly adjusting the geometrical parameters of the asymmetric nanoapertures. The mechanisms for manipulating and tuning the localized fields are also discussed.  相似文献   

8.
Ultrastructurally the spermatozoon of Acanthopagrus schlegeli (Sparidae) has a spherical, homogeneously electron-dense nucleus with a deep axial nuclear fossa, and an unusual notch, shaped like a bowtie, in the nuclear region. The short midpiece contains four spherical mitochondria and encircles the basal body of the flagellum. It is concluded that the spermatozoon is of a primitive type, although it is characterized by several unique features which may provide useful systematic characters. © 1993 Wiley-Liss, Inc.  相似文献   

9.
IntroductionA mathematical 3D model of an existing computed tomography (CT) scanner was created and used in the EGSnrc-based BEAMnrc and egs_cbct Monte Carlo codes. Simulated transmission dose profiles of a RMI-465 phantom were analysed to verify Hounsfield numbers against measured data obtained from the CT scanner.Methods and materialsThe modelled CT unit is based on the design of a Toshiba Aquilion 16 LB CT scanner. As a first step, BEAMnrc simulated the X-ray tube, filters, and secondary collimation to obtain phase space data of the X-ray beam. A bowtie filter was included to create a more uniform beam intensity and to remove the beam hardening effects. In a second step the Interactive Data Language (IDL) code was used to build an EGSPHANT file that contained the RMI phantom which was used in egs_cbct simulations. After simulation a series of profiles were sampled from the detector model and the Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct transversal images. The results were tested against measured data obtained from CT scans.ResultsThe egs_cbct code can be used for the simulation of a fan beam CT unit. The calculated bowtie filter ensured a uniform flux on the detectors. Good correlation between measured and simulated CT numbers was obtained.ConclusionsIn principle, Monte Carlo codes such as egs_cbct can model a fan beam CT unit. After reconstruction, the images contained Hounsfield values comparable to measured data.  相似文献   

10.
Structured subwavelength apertures have been studied widely to enhance the transmission or obtain super resolution, such as bull’s eye hole, H-shaped aperture, and bowtie aperture. In this letter, we present another structured aperture with two gaps inside, which can also lead to near-field enhancement. And the resonance wavelength can be tuned by the geometric parameters of the gaps. The enhancement of this gap-aperture depends strongly on the polarization of the incident wave. Only the polarization perpendicular to the connecting line of the two gaps can realize the enhancement. We attribute the near-field enhancement of this structured aperture to the resonance excitation of the localized surface plasmon. We combine the tooth-aperture and our gap-aperture together and this special aperture can achieve stronger enhancement and super resolution simultaneously.  相似文献   

11.
《Genomics》2019,111(6):1824-1830
Metagenome from refinery wastewater treatment plant running under nitrogen stress was analyzed for mining of novel aromatic hydrocarbon-degrading bacteria. The sequence data were assembled using metaspade followed by binning using the Metabat tool to assemble genome; where coverage and depth were calculated using bowtie and samtools. The analysis picked a novel genome belonging to family Bradyrhizobiaceae, identified based on 16S rDNA gene which was supported by CheckM and Kraken analysis. Using RAST, the assembled genome showed the capabilities for nitrogen fixation with the utilization of multiple hydrocarbon substrates with 14 different types of oxygenases as mapped by Minpath. An additional genetic feature like genes for stress and resistance towards heavy metals and antibiotic suggested that the genome has gone through the rigorous process of adaptation. If such bacteria could be cultivated then it will open the broad window of bioremediation strategies under nitrogen stress environment.  相似文献   

12.
Liu  Yuanyuan  Li  Kangkang  Cao  Sainan  Xiong  Guang  Zhu  Lu 《Plasmonics (Norwell, Mass.)》2019,14(6):1577-1586

A new genetic algorithm (GA)-based multi-slot nanoantenna is proposed for energy harvesting, which consists of two element nanoantennas with rectangular shape and with double bowtie double ring (DBDR) slot. The DBDR slot structure can enhance the electric field to increase the absorptivity of nanoantennas; however, the larger parameter space of multi-slot is more hardly controlled. Therefore, we use GA to optimize the parameters of the DBDR slot nanoantenna and the Finite-Difference Time-Domain method to calculate the absorptivity. It is found that absorptivity of the optimized nanoantenna is over 77% in 400–1800 nm waveband. We attribute the better absorbing property of the nanoantenna to the synergistic effect of the localized surface plasmon resonance enhancement and coupling between slots.

  相似文献   

13.
The near-field resonances of gold bowtie antennae are numerically modeled. Besides the short-range surface plasmon polariton (SR-SPP) mode along the main axis of the structure, a coupled SPP mode is also found in the gap region (G-SPP). The influence of adhesion layers is considered, which depends on the refractive index and the absorption of the adhesion material and whether it is continuous or etched. A high refractive index causes the peak of the SR-SPP to red-shift. High absorption quenches the intensity of the SR-SPP. The magnitude of influence depends on the overlap of the adhesion layer with the SR-SPP and G-SPP modes. The near-field resonance of the SPP mode on the top surface is also considered. An etched metal adhesion layer changes the near-field localization in the gap and causes the enhancement peaks at different heights within the gap to red-shift from top to bottom. A simple optimization method for the near-field localization by the combination of different top and bottom layers is demonstrated.  相似文献   

14.
In this paper, we report a characteristic transmission control property of a nano-optical system by introducing an antenna over the input opening of a bowtie aperture. The transmission process through the system is investigated quantitatively by the coupling and transmission efficiencies, and an optical switch effect is found as the antenna length varies. To understand the physical mechanism, we then investigate the electrical field distribution of the antenna over a rectangle aperture as a simplified model. It is discovered that the "on" state of the system is due to Fabry–Perot resonances in the horizontal cavity formed by antenna, dielectric layer, and metal film. On the other hand, a cutoff occurs for the characteristic rectangle length shorter than the diffraction limit to turn the device to the "off" state. Such a phenomenon can thus provide a promising candidate for application in manipulating light in large-scale optoelectronic device integration.  相似文献   

15.
Photonic devices can be developed, and their working principle can be understood only by considering the phenomena taking place at the nanoscale level. Optical properties of plasmonic structures depend on their geometric parameters and are sensitive to them. Recently, many advanced methods for the preparation of nanostructures have been proposed; however still, the geometric parameters are inaccurate. Numerical simulations provide a powerful tool for the analysis of plasmonic nanostructures. To the best of our knowledge, there are not many papers on near-field and far-field properties of single nanoprism and nanoprism dimer, the so-called bowtie, with rounded edges. For this purpose, Finite Integration Technique implemented to the CST Microwave Studio was used. Besides the edge rounding, an additional modification of the resonance modes was investigated, achieved by placement of a spherical nanoparticle in the gap between the prisms. Results of numerical simulations indicate that the radius of the curvature edges strongly affects the plasmon peak localization, and this effect cannot be neglected in plasmonic device design. Increase in the radius of edge curvature causes main extinction cross-section peak blueshift in all cases analyzed. Moreover, our calculations imply that the nanoparticle in the gap between prisms strongly influences the dependence of spectral properties on the radius curvature.  相似文献   

16.
PurposeTo investigate lens dose reduction with organ based tube current modulation (TCM) using the Monte Carlo method.MethodsTo calculate lens dose with organ based TCM, 36 pairs of X-ray sources with bowtie filters were placed around the patient head using a projection angle interval of 10° for one rotation of Computed Tomography (CT). Each projection was simulated respectively. Both voxelized and stylized eye models and Chinese reference male phantoms were used in the simulation, and tube voltages 80, 100, 120 and 140 kVp were used.ResultsDose differences between two eye models were less than 20%, but large variations were observed among dose results from different projections of all tube voltages investigated. Dose results from 0° (AP) directions were 60 times greater than those from 180° (PA) directions, which enables organ based TCM reduce lens doses by more than 47%.ConclusionsOrgan based TCM may be used to reduce lens doses. Stylized eye models are more anatomically realistic compared with voxelized eye models and are more reliable for dose evaluation.  相似文献   

17.
PurposeTo experimentally investigate the effect of the scan field of view (SFOV) selection and table height settings on the Computed Tomography Dose Index (CTDI) and the implications concerning patient effective and skin dose.MethodsAir-kerma length product (AKLP) measurements were carried out in a helical CT scanner using a pencil type dosimeter positioned in air and inside the holes of a head and a body phantom, using all available SFOV selections and different table height settings. Furthermore, using radiotherapy verification films placed on the CT table surface, the entrance surface air kerma (ESAK) profiles were derived with different SFOV and table height selections, both with and without a phantom on top of the films.ResultsThe AKLP is strongly dependent on the SFOV selection and the table height settings. Different SFOV selections correspond to the selection of different bowtie filters that shape the X-ray beam intensity, resulting in different ESAK values at the isocenter and at the other points within the scanning plane. With the off-center positioning the calculated CTDI values within the center and the periphery of the phantom change also, as a result of the different intensity and width of the X-ray beam to which are exposed to.ConclusionsThe existing protocols for calculating effective dose are limited to only two patient anatomy-SFOV combinations and cannot account for off-center positioning. Therefore, more work will be required to estimate the effective and skin dose for non-standard SFOV-patient anatomy combinations and off-center patient positioning.  相似文献   

18.
PurposeTo present a framework for characterizing the data needed to implement a polyenergetic model-based statistical reconstruction algorithm, Alternating Minimization (AM), on a commercial fan-beam CT scanner and a novel method for assessing the accuracy of the commissioned data model.MethodsThe X-ray spectra for three tube potentials on the Philips Brilliance CT scanner were estimated by fitting a semi-empirical X-ray spectrum model to transmission measurements. Spectral variations due to the bowtie filter were computationally modeled. Eight homogeneous cylinders of PMMA, Teflon and water with varying diameters were scanned at each energy. Central-axis scatter was measured for each cylinder using a beam-stop technique. AM reconstruction with a single-basis object-model matched to the scanned cylinder's composition allows assessment of the accuracy of the AM algorithm's polyenergetic data model. Filtered-backprojection (FBP) was also performed to compare consistency metrics such as uniformity and object-size dependence.ResultsThe spectrum model fit measured transmission curves with residual root-mean-square-error of 1.20%–1.34% for the three scanning energies. The estimated spectrum and scatter data supported polyenergetic AM reconstruction of the test cylinders to within 0.5% of expected in the matched object-model reconstruction test. In comparison to FBP, polyenergetic AM exhibited better uniformity and less object-size dependence.ConclusionsReconstruction using a matched object-model illustrate that the polyenergetic AM algorithm's data model was commissioned to within 0.5% of an expected ground truth. These results support ongoing and future research with polyenergetic AM reconstruction of commercial fan-beam CT data for quantitative CT applications.  相似文献   

19.
The operation of the bowtie filter in x-ray CT is correct if the object being scanned is properly centered in the scanner’s field-of-view. Otherwise, the dose delivered to the patient and image noise will deviate from optimal setting. We investigate the effect of miscentering on image noise and surface dose on three commercial CT scanners. Six cylindrical phantoms with different size and material were scanned on each scanner. The phantoms were positioned at 0, 2, 4 and 6 cm below the isocenter of the scanner’s field-of-view. Regression models of surface dose and noise were produced as a function of miscentering magnitude and phantom’s size. 480 patients were assessed using the calculated regression models to estimate the influence of patient miscentering on image noise and patient surface dose in seven imaging centers. For the 64-slice CT scanner, the maximum increase of surface dose using the CTDI-32 phantom was 13.5%, 33.3% and 51.1% for miscenterings of 2, 4 and 6 cm, respectively. The analysis of patients’ scout scans showed miscentering of 2.2 cm in average below the isocenter. An average increase of 23% and 7% was observed for patient dose and image noise, respectively. The maximum variation in patient miscentering derived from the comparison of imaging centers using the same scanner was 1.6 cm. Patient miscentering may substantially increase surface dose and image noise. Therefore, technologists are strongly encouraged to pay greater attention to patient centering.  相似文献   

20.
普通小麦与粗山羊草正,反交的育性研究   总被引:13,自引:0,他引:13  
普通小麦与粗山羊草杂交需借助幼胚培养方可获得杂种,取授粉12~16天的幼胚进行拯拯救,成苗率较高,效果较好。而不同杂交方式对共杂种成胚率、成苗率及思胚拯救率影响很大。以普通小麦为母本,粗山羊草为父杂交时,15个杂交组合平均杂种成胚率,成苗率及幼胚拯率分别为5.35%和58.73%,而在12个反交组合中,其平均成胚率,成苗率及幼胚拯救率分别为98.88%、17.10%和24.44%。由此可见,普通小  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号