首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
IntroductionWhen ictal and interictal brain SPECT are reconstructed with filtered backprojection (FBP), the noise level of subtraction images is frequently high and requires the use of thresholding methods. The aim of this study was to compare the subtraction images for cerebral SPECT reconstructed either with FBP or with a 3D iterative reconstruction method (OSEM-3D).Material and methodsAfter optimisation of the reconstruction parameters on phantom, the subtraction SPECT images, which were obtained with FBP or with OSEM-3D and coregistered with MRI images, were analyzed in 15 patients with refractory temporal epilepsy.ResultsOn phantom and with the constrain of high enough spatial resolution (full width at half of maximum for a punctual source less than or equal to 11 mm) were reached using: (i) a Butterworth filter with a cut-off frequency of 0.4 Nyquist at order 6 for FBP and (ii) five iterations, 16 subsets and a 9 mm gaussian filter for OSEM-3D. On the subtraction images, which were obtained with these optimal parameters, the temporal foci from patients were smaller with OSEM-3D than with FBP (11 ± 6 cm3 versus 17 ± 10 cm3, P = 0.02), mean voxel activities were equivalent between the two methods within temporal foci (6.30 ± 3.13 counts versus 6.34 ± 4.93 counts) but these activities were dramatically reduced by OSEM-3D within background regions (0.02 ± 0.02 counts versus 0.19 ± 0.12 counts, P < 0.001).ConclusionFor the ictal–interictal subtraction SPECT images, which are obtained in patients with refractory temporal epilepsy, the use of an optimized OSEM-3D method leads to dramatically reduce the volume of temporal foci, as well as the background noise level, two properties that are likely to facilitate the detection and localisation of epilepsy foci.  相似文献   

2.
PurposeThis study aimed to determine whether the SiPM-PET/CT, Discovery MI (DMI) performs better than the PMT-PET/CT system, Discovery 710 (D710).MethodsThe physical performance of both systems was evaluated using NEMA NU 2 standards. Contrast (%), uniformity and image noise (%) are criteria proposed by the Japanese Society of Nuclear Medicine (JSNM) for phantom tests and were determined in images acquired from Hoffman and uniform phantoms using the DMI and D710. Brain and whole-body [18F]FDG images were also acquired from a healthy male using the DMI and D710.ResultsThe spatial resolution at 1.0 cm off-center in the DMI and D710 was 3.91 and 4.52 mm, respectively. The sensitivity of the DMI and D710 was 12.62 and 7.50 cps/kBq, respectively. The observed peak noise-equivalent count rates were 185.6 kcps at 22.5 kBq/mL and 137.0 kcps at 29.0 kBq/mL, and the scatter fractions were 42.1% and 37.9% in the DMI and D710, respectively. The D710 had better contrast recovery and lower background variability. Contrast, uniformity and image noise in the DMI were 61.0%, 0.0225, and 7.85%, respectively. These outcomes were better than those derived from the D710 and satisfied the JSNM criteria. Brain images acquired by the DMI had better grey-to-white matter contrast and lower image noise at the edge of axial field of view.ConclusionsThe DMI offers better sensitivity, performance under conditions of high count rates and image quality than the conventional PMT-PET/CT system, D710.  相似文献   

3.
《Médecine Nucléaire》2017,41(2):99-107
ObjectiveWe compared two reconstruction methods for 18fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) images with “attenuation weighted ordered subset expectation maximization” using either the manufacturer-provided (AW-OSEM) or a “Detector response” (AW-OSEM DR) tomographic operator. We looked at the feasibility of using the latter reconstruction for radiotherapy target volumes definition in cancers of the superior aero-digestive tract (VADS). In this preliminary study, we first assessed the spatial resolution of images obtained with AW-OSEM and AW-OSEM DR on a Biograph™ 6, and secondly target volumes of radiotherapy “Gross Tumor Volume” (GTV), “Clinical Target Volume” (CTV) and “Planning Target Volume” (PTV) obtained with each of these reconstruction methods.Material and methodsThe spatial resolution was measured on a test object containing 4 radioactive point sources. Furthermore, radiotherapy target volumes have been defined with the software Eclipse™ on injected scanner (CT IV) and PET/CT (PET AW-OSEM and PET AW-OSEM DR) images.ResultsSpatial resolution was improved with AW-OSEM DR algorithm reconstruction compared to images obtained with AW-OSEM reconstruction (from 7.5 mm down to 5.4 mm for the highest reduction). GTV from AW-OSEM DR reconstruction with 42 and 50% of the “Standard uptake value maximum” (SUVmax) semi-automatic threshold (1.2 and 0.7 cm3 respectively) were lower than those obtained with AW-OSEM (3.6 and 2.2 cm3 respectively). They were also lower than GTV defined with CT IV (5.5 cm3). It was the same for CTV and PTV.ConclusionThis study showed that AW-OSEM DR reconstruction method allows less impaired spatial resolution than AW-OSEM. In the case of radiotherapy target volumes delineation, AW-OSEM DR may decrease the GTV, CTV and PTV and therefore the risk of side effects associated with organs at risk.  相似文献   

4.
PurposeWe performed the first investigations, via measurements and Monte Carlo simulations on phantoms, of the feasibility of a new technique for synchrotron radiation rotational radiotherapy for breast cancer (SR3T).MethodsA Monte Carlo (MC) code based on Geant4 toolkit was developed in order to simulate the irradiation with the SR3T technique and to evaluate the skin sparing effect in terms of centre-to-periphery dose ratio at different energies in the range 60–175 keV. Preliminary measurements were performed at the Australian Synchrotron facility. Radial dose profiles in a 14-cm diameter polyethylene phantom were measured with a 100-mm pencil ionization chamber for different beam sizes and compared with the results of MC simulations. Finally, the dose painting feasibility was demonstrated with measurements with EBT3 radiochromic films in a phantom and collimating the SR beam at 1.5 cm in the horizontal direction.ResultsMC simulations showed that the SR3T technique assures a tumour-to-skin absorbed dose ratio from about 7:1 (at 60 keV photon energy) to about 10:1 (at 175 keV), sufficient for skin sparing during radiotherapy. The comparison between the results of MC simulations and measurements showed an agreement within 5%. Two off-centre foci were irradiated shifting the rotation centre in the horizontal direction.ConclusionsThe SR3T technique permits to obtain different dose distributions in the target with multiple rotations and can be guided via synchrotron radiation breast computed tomography imaging, in propagation based phase-contrast conditions. Use of contrast agents like iodinated solutions or gold nanoparticles for dose enhancement (DE-SR3T) is foreseen and will be investigated in future work.  相似文献   

5.
ObjectiveThis study aims to assess low-contrast image quality using a low-contrast object specific contrast-to-noise ratio (CNRLO) analysis for iterative reconstruction (IR) computed tomography (CT) images.MethodsA phantom composed of low-contrast rods placed in a uniform material was used in this study. Images were reconstructed using filtered back projection (FBP) and IR (Adaptive Iterative Dose Reduction 3D). Scans were performed at six dose levels: 1.0, 1.8, 3.1, 4.6, 7.1 and 13.3 mGy. Objective image quality was assessed by comparing CNRLO with CNR using a human observer test.ResultsCompared with FBP, IR yielded increased CNR at the same dose levels. The results of CNRLO and observer tests showed similarities or only marginal differences between FBP and IR at the same dose levels. The coefficient of determination for CNRLO was significantly better (R2 = 0.86) than that of CNR (R2 = 0.47).ConclusionFor IR, CNRLO could potentially serve as an objective index reflective of a human observer assessment. The results of CNRLO test indicated that the IR algorithm was not superior to FBP in terms of low-contrast detectability at the same radiation doses.  相似文献   

6.
《Médecine Nucléaire》2020,44(1):26-32
Objective18F-FDG PET/CT is for the moment not recommended for stage T of the TNM classification of breast cancer. The aim of our study was to evaluate the performance of 18F-FDG PET/CT in the initial staging of breast tumors. Tumor size, skin involvement and inflammation as well as the relationship between primary tumor maximum standardized uptake value (SUVmax) and histopathological grade (SBR), molecular tumor subtypes (luminal A and B, Her2 enriched, triple negative), estrogen receptors (ER), progesterone receptors (PR) and focality were evaluated.MethodsHistological reports of patients operated for breast cancer, without neoadjuvant chemotherapy, were compared to preoperative 18F-FDG PET/CT.ResultsSeventy-four patients who underwent surgery in 2016 were included. 18F-FDG PET/CT was able to visualize primary tumors in 91% and to correctly classify the T stage of the TNM classification in 81% of the cases, to detect multifocality in 73% and cutaneous and inflammatory breast cancers in 100%. The uptake intensity of 18F-FDG (SUVmax) was significantly correlated with histo-prognostic factors such as SBR grade (P = 0.02), lack of expression of estrogen receptors (ER) (P = 0.01) and progesterone (PR) (P = 0.02), positive HER2 status (P = 0.01) or triple negative subtype tumors (P = 0.02).Conclusion18F-FDG PET/CT provides relevant elements for local assessment, in particular, tumor focality and inflammatory character in addition to ensuring the regional and extension assessment.  相似文献   

7.
AimThe aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy.BackgroundRadiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks.Materials and methodsA total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated.ResultsThe best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p  0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior–inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm.ConclusionsSetup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.  相似文献   

8.
《Theriogenology》2008,69(9):1316-1325
In this study, we evaluated a serum replacer (SR; Knockout SR®, Invitrogen) in our in vitro culture systems. We hypothesized that SR would benefit bovine embryo development, since SR supported survival of embryonic stem cells (which originate from embryos). Experiment 1 compared oocyte maturation with SR versus fetal bovine serum (FBS). Following fertilization, blastocyst development was lower for oocytes matured with SR (21.5 versus 34.1, P < 0.05). Experiment 2 evaluated SR for culturing embryos. Following fertilization, embryos were cultured for 3 days in KSOM, and then assigned to treatments: (1) KSOM static culture (KNM); (2) fresh KSOM (KD3); (3) KSOM + SR or (4) KSOM + FBS and cultured to Day 7 (fertilization = Day 0). Blastocyst development in FBS or SR was higher than either KNM or KD3 (48.2, 47.2, 32.7, and 35.5, respectively, P < 0.05). Experiment 3 evaluated cryosurvival of embryos cultured in the same manner as Experiment 2. On Day 7, embryos were vitrified and upon warming, embryos cultured in SR had greater 24 h survival rates (70.6%) than all other treatments (P < 0.05). Finally, Experiment 4 evaluated effects of SR on pregnancy rate and development to term. Culture in SR was not detrimental to pregnancy or calving rates (50 and 50%, respectively), and SR calves had normal birth weights (mean = 38.8 kg ± 1.5). In conclusion, the use of SR for maturation of oocytes was not beneficial; however, SR enhanced embryo culture by improving development in vitro, cryotolerance and survival, effectively replacing serum in culture.  相似文献   

9.
Electron beam damage is the fundamental limit to resolution in electron cryomicroscopy (cryo-EM) of frozen, hydrated specimens. Radiation damage increases with the number of electrons used to obtain an image and affects information at higher spatial frequencies before low-resolution information. For the experimentalist, a balance exists between electron exposures sufficient to obtain a useful signal-to-noise ratio (SNR) in images and exposures that limit the damage to structural features. In single particle cryo-EM this balance is particularly delicate: low-resolution features must be imaged with a sufficient SNR to allow image alignment so that high-resolution features recorded below the noise level can be recovered by averaging independent images. By measuring the fading of Fourier components from images obtained at 200 kV of thin crystals of catalase embedded in ice, we have determined the electron exposures that will maximize the SNR at resolutions between 86 and 2.9 Å. These data allow for a rational choice of exposure for single particle cryo-EM. For example, for 20 Å resolution, the SNR is maximized at ~20 e?2, whereas for 3 Å resolution, it is maximized at ~10 e?2. We illustrate the effects of exposure in single particle cryo-EM with data collected at ~12–15 and ~24–30 e?2.  相似文献   

10.
BACKGROUNDImportance of androgen receptor (AR) as an independent prognostic marker in Pakistani women with breast cancer (BCa) remains unexplored. Our aim was to identify the expression and potential prognostic value of AR, its upstream regulator (pAkt) and target gene (pPTEN) in invasive BCa.METHODSThis study used a cohort of 200 Pakistani women with invasive BCa diagnosed during 2002-2011. Expression of AR, pAkt and pPTEN was determined on formalin fixed paraffin embedded tissue sections by immunohistochemistry. The association of AR, pAkt and pPTEN with clinicopathological parameters was determined. Survival analyses were undertaken on patients with ≥ 5 years of follow-up (n = 82).RESULTSExpression of AR, pAkt and pPTEN was observed in 47.5%, 81.3% and 50.6% of patients, respectively. AR-expressing tumors were low or intermediate in grade (P < .001) and expressed ER (P = .002) and PR (P = .001). Patients with AR+ tumors had significantly higher OS (Mean OS = 10.2 ± 0.465 years) compared to patients with AR? tumors (Mean OS = 5.8 ± 0.348 years) (P = .047). Furthermore, AR-positivity was associated with improved OS in patients receiving endocrine therapy (P = .020). Patients with AR+ /pAkt+ /pPTEN? tumors, had increased OS (Mean OS = 7.1 ± 0.535 years) compared to patients with AR?/pAkt+/pPTEN? tumors (Mean OS = 5.1 ± 0.738 years).CONCLUSIONAR-expressing tumors are frequently characterized by low or intermediate grade tumors, expressing ER and PR. In addition, expression of AR, pAkt and pPTEN, could be considered in prognostication of patients with invasive BCa.  相似文献   

11.
PurposeWe developed a high performance portable gamma camera platform dedicated to identification of sentinel lymph nodes (SLNs) and radio-guided surgery for cancer patients. In this work, we present the performance characteristics of SURGEOSIGHT-I, the first version of this platform that can intra-operatively provide high-resolution images of the surveyed areas.MethodsAt the heart of this camera, there is a 43 × 43 array of pixelated sodium-activated cesium iodide (CsI(Na)) scintillation crystal with 1 × 1 mm2 pixel size and 5 mm thickness coupled to a Hamamatsu H8500 flat-panel multi-anode (64 channels) photomultiplier tube. The probe is equipped with a hexagonal parallel-hole lead collimator with 1.2 mm holes. The detector, collimator, and the associated front-end electronics are encapsulated in a common housing referred to as head.ResultsOur results show a count rate of ∼41 kcps for 20% count loss. The extrinsic energy resolution was measured as 20.6% at 140 keV. The spatial resolution and the sensitivity of the system on the collimator surface was measured as 2.2 mm and 142 cps/MBq, respectively. In addition, the integral and differential uniformity, after uniformity correction, in useful field-of-view (UFOV) were measured 4.5% and 4.6%, respectively.ConclusionsThis system can be used for a number of clinical applications including SLN biopsy and radiopharmaceutical-guided surgery.  相似文献   

12.
Background aimsA phase I trial examined the ability of immunotherapy to mobilize progenitor and activated T cells.MethodsInterleukin (IL)-2 was administered subcutaneously for 11 days, with granulocyte (G)-colony-stimulating factor (CSF) (5 mcg/kg/day) and granulocyte–macrophage (GM)-CSF (7.5 mcg/kg/day) added for the last 5 days. Leukapheresis was initiated on day 11. Thirteen patients were treated (myeloma n = 11, non-Hodgkin's lymphoma n = 2).ResultsToxicities were minimal. IL-2 was stopped in two patients because of capillary leak (n = 1) and diarrhea (n = 1). Each patient required 2.5 leukaphereses (median; range 1–3) to collect 3.2 × 106 CD34+ cells/kg (median; range 1.9–6.6 × 106/kg). Immune mobilization increased the number of CD3+ CD8+ T cells (P = 0.002), CD56+ natural killer (NK) cells (P = 0.0001), CD8+ CD56+ T cells (P = 0.002) and CD4+ CD25+ cells (P = 0.0001) compared with cancer patients mobilized with G-CSF alone. There was increased lysis of myeloma cells after 7 days (P = 0.03) or 11 days (P = 0.02). The maximum tolerated dose of IL-2 was 1 × 106 IU/m2/day.ConclusionsImmune mobilization is well tolerated with normal subsequent marrow engraftment. As cells within the graft influence lymphocyte recovery, an increased number of functional lymphocytes may result in more rapid immune reconstitution.  相似文献   

13.
A high spatial resolution sampling of Alexandrium pacificum cysts, along with sediment characteristics (% H2O, % organic matter (OM), granulometry), vegetative cell abundance and environmental factors were investigated at 123 study stations in Bizerte Lagoon (Tunisia). Morphological examination and ribotyping of cells obtained from a culture called ABZ1 obtained from a cyst isolated in lagoon sediment confirmed that the species was A. pacificum. The toxin profile from the ABZ1 culture harvested during exponential growth phase was simple and composed of the N-sulfocarbamoyl toxins C1 (9.82 pg toxin cell−1), the GTX6 (3.26 pg toxin cell−1) and the carbamoyl toxin Neo-STX (0.38 pg toxin cell−1). The latter represented only 2.8% of the total toxins in this strain.High abundance of A. pacificum cysts correlated with enhanced percentages of water and organic matter in the sediment. In addition, sediment fractions of less than 63 μm were examined as a favorable potential seedbed for initiation of future blooms and outbreaks of A. pacificum in the lagoon. A significant difference in the cyst distribution pattern was recorded among the lagoon's different zones, with the higher cyst abundance occurring in the inner waters. Also, no correlation due to the specific hydrodynamics of the lagoon was observed in the spatial distribution of A. pacificum cysts and vegetative cells.  相似文献   

14.
Anterior cruciate ligament (ACL) volume and T21 relaxation times from magnetic resonance (MR) images have been previously shown to predict the structural properties of healing ligaments. We investigated whether MR imaging scan resolution and condition (in vivo, in situ, or ex vivo) affected ACL volume and T21 relaxation times in intact ligaments. ACLs of 14 pigs were imaged using a 3 T scanner and a six-channel flexcoil using at least two of four possible scan conditions: (1) in vivo moderate resolution (n = 14); (2) in vivo high resolution (n = 7); (3) in situ high resolution acquired within 60 minutes of euthanasia (n = 6); and (4) ex vivo high resolution following hind limb disarticulation and one freeze-thaw cycle (n = 7). T21 relaxation times were mapped to the ACL voxels. The total ACL volume was then divided into four sub-volumes (Vol1–4) based on predetermined increasing ranges of T21 times. ACL T21 statistics (first quartile, median, and standard deviation (SD)) were computed. Scan resolution had no effect on the total ACL volume, but Vol1 and first quartile T21 times decreased with high resolution and in situ/ex vivo scan conditions. The most dramatic differences in T21 summary statistics were between in vivo moderate and ex vivo high resolution scan conditions that included a freeze-thaw cycle: ACL T21 SD increased by over 50% in 9 animals, and more than 90% in 4 animals. Our results indicated that T21-based prediction models to quantify in vivo structural properties of healing ligaments should be based on high resolution in vivo MR scan conditions.  相似文献   

15.
PurposeTo evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR).MethodsThree anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom.ResultsThe use of AEC produced a significant dose reduction (p < 0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p < 0.01) and reduced SNR and CNR (p < 0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency.ConclusionsIn chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices.  相似文献   

16.
Retrieving leaf chlorophyll content at a range of spatio-temporal scales is central to monitoring vegetation productivity, identifying physiological stress and managing biological resources. However, estimating leaf chlorophyll over broad spatial extents using ground-based traditional methods is time and resource heavy. Satellite-derived spectral vegetation indices (VIs) are commonly used to estimate leaf chlorophyll content, however they are often developed and tested on broadleaf species. Relatively little research has assessed VIs for different leaf structures, particularly needle leaves which represent a large component of boreal forest and significant global ecosystems. This study tested the performance of 47 published VIs for estimating foliar chlorophyll content from different leaf and canopy structures (broadleaf and needle). Coniferous and deciduous sites were selected in Ontario, Canada, representing different dominant vegetation species (Picea mariana and Acer saccharum) and a variety of canopy structures. Leaf reflectance data was collected using an ASD Fieldspec Pro spectroradiometer (400–2500 nm) for over 300 leaf samples. Canopy reflectance data was acquired from the medium resolution imaging spectrometer (MERIS). At the canopy level, with both leaf types combined, the DD-index showed the strongest relationship with leaf chlorophyll (R2 = 0.78; RMSE = 3.56 μg/cm2), despite differences in leaf structure. For needleleaf trees alone the relationship with the top VI was weaker (D[red], R2 = 0.71; RMSE = 2.32 μg/cm2). A sensitivity study using simulated VIs from physically-modelled leaf (PROSPECT) and canopy (4-Scale) reflectance was performed in order to further investigate these results and assess the impacts of different background types and leaf area index on the VIs’ performance. At the leaf level, the MNDVI8 index showed a strong linearity to changing chlorophyll and negligible difference to leaf structure/type. At canopy level, the best performing VIs were relatively consistent where LAI  4, but responded strongly to differences in background at low canopy coverage (LAI = 2). This research provides comprehensive assessments for the use of spectral indices in retrieval of spatially-continuous leaf chlorophyll content at the leaf (MTCI: R2 = 0.72; p < 0.001) and canopy (DD: R2 = 0.78; p < 0.001) level for resource management over different spatial and temporal scales.  相似文献   

17.
BackgroundNew CZT cameras provide an increased spatial resolution and sensitivity. The tomographic acquisition “in list mode” allows the evaluation of the left ventricular function using 8–16 intervals per cycle with an increased spatial resolution. However, the impact of temporal sampling on evaluation of the contractile function remains uncertain.Method99mTc-sestamibi SPECT studies were acquired in 99 consecutive patients (70 men, 29 women) using an ultrafast CZT Camera (D-Spectrum, Spectrum Dynamics) and processed using both 8- and 16-interval (int). All patients underwent a stress (2 MBq/kg)-rest (6 MBq/kg) single day (stop condition: 700 KCTS within a myocardial VOI). Left ventricular function was assessed using QGS®. Perfusion was analyzed using QPS® and quantified using Summed Stress Score (SSS), Summed Rest Score (SRS) and Summed Difference Score (SDS) (17 segments model) and the extent of perfusion defects (% of LV).ResultsEight intervals gating overestimated the end-systolic volumes (ESV) and underestimated the left ventricular ejection fraction (LVEF) compared to 16 intervals (respectively for eight and 16 intervals: at rest [VTS: 45 ± 25 mL vs 41 ± 24 mL, P < 0.0001, LVEF: 53 ± 10% vs 59 ± 10%, P < 0.0001], and post-stress [VTS: 43 ± 24. mL vs 39 ± 24 mL, P < 0.0001; LVEF: 58 ± 10% vs 61 ± 11%, P < 0.0001]). However, it was not found significant differences between end diastolic volumes (EDV) (at rest: EDV: 98 ± 33 mL vs 97 ± 33 mL, P = NS; and post-stress: EDV: 98 ± 33 ml vs 99 ± 34 mL, P = NS). Parameters of left ventricular function were consistent between eight and 16 intervals (EDV: CCC = 0.99, ESV: CCC = 0.98, LVEF: CCC = 0.92, P < 0.0001). Correlation could not be evidenced between the extent of perfusion defect and the difference between eight and 16 intervals for the different parameters of left ventricular function both at rest and post-stress.ConclusionIn our study, comparison between eight and 16 intervals showed an overestimation of the ESV and an underestimation of LVEF, without correlation with perfusion abnormalities. The estimation of LVEF on CZT camera should take into account the chosen temporal sampling.  相似文献   

18.
PurposeTo compare the effective dose (ED) and image quality (IQ) of O-arm cone-beam CT (Medtronic, Minneapolis, MN, USA) and Airo multi-slice CT (Brainlab AG, Munich, Germany) for intraoperative-CT (i-CT) in spinal surgery.MethodsThe manufacturer-defined protocols available in the O-arm and Airo systems for three-dimensional lumbar spine imaging were compared.Organ dose was measured both with thermo-luminescent dosimeters and GafChromic films in the Alderson Radiation Therapy anthropomorphic phantom.A subjective analysis was performed by neurosurgeons to compare the clinical IQ of the anthropomorphic phantom images acquired with the different i-CT systems and imaging protocols.Image uniformity, noise, contrast-to-noise-ratio (CNR), and spatial resolution were additionally assessed with the Catphan 504 phantom.ResultsO-arm i-CT caused 56% larger ED than Airo due to the high definition (HD) imaging protocol.The noise was larger for O-arm images leading to a lower CNR than that measured for Airo. Moreover, scattering and beam hardening effects were observed in the O-arm images. Better spatial resolution was measured for the O-arm system (9 lp/cm) than for Airo (4 lp/cm).For all the investigated protocols, O-arm was found to be better for identifying anatomical features important for accurate pedicle screw positioning.ConclusionsAccording to phantom measurements, the HD protocol of O-arm offered better clinical IQ than Airo but larger ED. The larger noise of O-arm images did not compromise the clinical IQ while the superior spatial resolution of this system allowed a better visibility of anatomical features important for pedicle screw positioning in the lumbar region.  相似文献   

19.
The present study aimed to investigate whether the in-plane resolution property of iterative reconstruction (IR) of computed tomography (CT) data is object shape-dependent by testing columnar shapes with diameters of 3, 7, and 10 cm (circular edge method) and a cubic shape with 5-cm side lengths (linear edge method). For each shape, objects were constructed of acrylic (contrast in Hounsfield units [ΔHU] = 120) as well as a soft tissue equivalent material (ΔHU = 50). For each shape, we measured the modulation transfer functions (MTFs) of IR and filtered back projection (FBP) using two multi-slice CT scanners at scan doses of 5 and 10 mGy. In addition, we evaluated a thin metal wire using the conventional method at 10 mGy. For FBP images, the MTF results of the tested objects and the wire method showed substantial agreement, thus demonstrating the validity of our analysis technique. For IR images, the MTF results of different shapes were nearly identical for each object contrast and dose combination, and we did not observe shape-dependent effects of the resolution properties of either tested IR. We conclude that both the circular edge method and linear edge method are equally useful for evaluating the resolution properties of IRs.  相似文献   

20.
PurposeTo show the usefulness of topographic 2D megavoltage images (MV2D) for the localization of breast cancer patients treated with TomoDirect (TD), a radiotherapy treatment technique with fixed-angle beams performed on a TomoTherapy system.MethodsA method was developed to quickly localize breast cancer patients treated with TD by registering the MV2D images produced before a TD treatment with reference images reconstructed from a kilovoltage CT simulation scanner and by using the projection of the beam-eye-view TD treatment field. Dose and image quality measurements were performed to determine the optimal parameters for acquiring MV2D images. A TD treatment was simulated on a chest phantom equipped with a breast attachment. MVCT and MV2D images were performed for 7 different shifted positions of the phantom and registered by 10 different operators with the simulation kilovoltage CT images.ResultsCompared to MVCT, MV2D imaging reduces the dose by a factor of up to 45 and the acquisition time by a factor of up to 49. Comparing the registration shift values obtained for the phantom images obtained with MVCT in the coarse mode to those obtained with MV2D, the mean difference is 1.0 ± 1.1 mm, −1.1 mm ± 1.1, and −0.1 ± 2.2 mm, respectively, in the lateral, longitudinal, and vertical directions.ConclusionsWith dual advantages (very fast imaging and a potentially reduced dose to the heart and contralateral organs), MV2D topographic images may be an attractive alternative to MVCT for the localization of breast cancer patients treated with TomoDirect.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号